{"id":"2025-volume-one","edition":"2025","volume":"volume-one","label":"NCC 2025 Volume One","short":"Volume One","who":"Class 2 to 9 buildings: apartments, commercial, industrial and public buildings","source":"https://ncc.abcb.gov.au/editions/ncc-2025/adopted/volume-one","built":"2026-11-23","licence":"The National Construction Code 2025 was provided by the Australian Building Codes Board under the CC BY 4.0 licence.","archive2019":{},"entries":[{"c":"Definition","t":"Above ground rainwater tank","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_84101919-d338-47aa-868a-f7a05648a569","x":"A rainwater tank that is not in any way set into the ground.","g":"/ncc/definitions/above-ground-rainwater-tank"},{"c":"Definition","t":"Accessible","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_30458e20-ec5e-4423-bb83-da0197428cd7","x":"Having features to enable use by people with a disability.","g":"/ncc/definitions/accessible"},{"c":"Definition","t":"Accessway","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_a9dd8ca7-e567-403a-bff7-e567012e1849","x":"A continuous accessible path of travel (as defined in AS 1428.1) to, into or within a building.","g":"/ncc/definitions/accessway"},{"c":"Definition","t":"Accredited Testing Laboratory","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_52d35595-b475-460e-ac5e-5cd3e0a72e5f","x":"One of the following:\nAn organisation accredited by the National Association of Testing Authorities Australia (NATA) to undertake the relevant tests.\nAn organisation outside Australia accredited to undertake the relevant tests by an authority recognised by NATA through a mutual recognition agreement.\nAn organisation recognised as being an Accredited Testing Laboratory under legislation at the time the test was undertaken.","g":"/ncc/definitions/accredited-testing-laboratory"},{"c":"Definition","t":"Activity support level","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_b160acb3-0def-418a-a768-7234eb49a88e","x":"The degree to which occupants can undertake activities with respect to the likely activity traits and occupant traits.","g":"/ncc/definitions/activity-support-level"},{"c":"Definition","t":"Activity traits","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_cbb65201-6660-4d50-9a5d-40d801c67de8","x":"For the purposes of—\nVolume One, the features of the activities that will be undertaken in a habitable room or space; or\nVolume Two, the features of the activities that will be undertaken in a room or space.","g":"/ncc/definitions/activity-traits"},{"c":"Definition","t":"Administering body","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_1dd9a959-04fa-420e-9c30-7017c1a1d2d6","x":"The body responsible for administering the WaterMark Certification Scheme.","g":"/ncc/definitions/administering-body"},{"c":"Definition","t":"Aged care building","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_41ac03c9-62e4-45df-84a3-8f31abb6b147","x":"A Class 9c building for residential accommodation of aged persons who, due to varying degrees of incapacity associated with the ageing process, are provided with personal care services and 24 hour staff assistance to evacuate the building during an emergency.","g":"/ncc/definitions/aged-care-building"},{"c":"Definition","t":"Agriculture (SA)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_086041ad-172b-4e7e-bb6e-1fcce531b86c","x":"Cropping, grazing, animal husbandry, intensive animal keeping, horticulture, aquaculture, wool shearing or dairy, but not viticulture or forestry.","g":"/ncc/definitions/agriculture-sa"},{"c":"Definition","t":"Aisle (NSW)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_7bd3266d-23ef-465c-a5c4-c548e11fa575","x":"A walkway at the end of rows of seating, not being continental seating, leading to a cross-over or to an egress doorway.","g":"/ncc/definitions/aisle-nsw"},{"c":"Definition","t":"Air-conditioning","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_386d327a-f182-4f1a-bf21-5cfdef50cc8d","x":"For the purposes of Section J of Volume One, a service that actively cools or heats the air within a space, but does not include a service that directly—\ncools or heats cold or hot rooms; or\nmaintains specialised conditions for equipment or processes, where this is the main purpose of the service.","g":"/ncc/definitions/air-conditioning"},{"c":"Definition","t":"Alarm zone","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_28831f44-1e80-4597-84f5-148cfde94e66","x":"For the purposes of Specification 23, an area of a building protected by one or more smoke alarms connected to one alarm circuit.","g":"/ncc/definitions/alarm-zone"},{"c":"Definition","t":"Allotment","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_12287a7f-71ac-46bd-a629-7648a4b5a252","x":"An area of land shown on an approved plan of subdivision for which a separate title is held or issued.","g":"/ncc/definitions/allotment"},{"c":"Table 1","t":"Alpine areas where snow loads are significant","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_6bd0bca7-d852-4b9f-90bc-a02485d7094d","x":"Location | Map identifier\nKiandra (NSW) | 1\nMount Kosciuszko (NSW) | 2\nPerisher Valley (NSW) | 3\nThredbo (NSW) | 4\nCabramurra (NSW) | 5\nCharlotte Pass Village (NSW) | 6\nDiggers Creek (NSW) | 7\nGuthega Village (NSW) | 8\nMount Blue Cow (NSW) | 9\nMount Selwyn (NSW) | 10\nPerisher Range (NSW) | 11\nRules Point (NSW) | 12\nSawpit Creek (NSW) | 13\nSmiggin Holes (NSW) | 14\nSmiggin Range (NSW) | 15\nThree Mile Dam (NSW) | 16\nWilsons Valley (NSW) | 17\nFalls Creek (Vic.), including Summit Area, Sun Valley and Village Bowl | 18\nMount Baw Baw (Vic.) | 19\nMount Buffalo (Vic.), including Chalet, Dingo Dell and Tatra | 20\nMount Buller (Vic.), including Baldy and Village | 21\nMount Hotham (Vic.), including Davenport and Village Centre | 22\nDinner Plain (Vic.) | 23\nLake Mountain (Vic.) | 24\nMount Stirling (Vic.) | 25\nBen Lomond Ski Field (Tas.) | 26\nCradle Valley (Tas.) | 27\nGreat Lake Area (Tas.) | 28\nMount Field Ski Field (Tas.) | 29","g":"/ncc/table-1"},{"c":"Definition","t":"Alpine area","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_a3d630dc-9b91-4e55-a890-971223fe3a75","x":"An area given in Figure 1 and in Table 1 for specific locations, and is—\nlikely to be subject to significant snowfalls; and\nin New South Wales, the ACT or Victoria more than 1200 m above the Australian Height Datum; and\nin Tasmania more than 900 m above the Australian Height Datum.\nTable 1 Alpine areas where snow loads are significant\nLocation\nMap identifier\nKiandra (NSW)\n1\nMount Kosciuszko (NSW)\n2\nPerisher Valley (NSW)\n3\nThredbo (NSW)\n4\nCabramurra (NSW)\n5\nCharlotte Pass Village (NSW)\n6\nDiggers Creek (NSW)\n7\nGuthega Village (NSW)\n8\nMount Blue Cow (NSW)\n9\nMount Selwyn (NSW)\n10\nPerisher Range (NSW)\n11\nRules Point (NSW)\n12\nSawpit Creek (NSW)\n13\nSmiggin Holes (NSW)\n14\nSmiggin Range (NSW)\n15\nThree Mile Dam (NSW)\n16\nWilsons Valley (NSW)\n17\nFalls Creek (Vic.), including Summit Area, Sun Valley and Village Bowl\n18\nMount Baw Baw (Vic.)\n19\nMount Buffalo (Vic.), including Chalet, Dingo Dell and Tatra\n20\nMount Buller (Vic.), including Baldy and Village\n21\nMount Hotham (Vic.), including Davenport and Village Centre\n22\nDinner Plain (Vic.)\n23\nLake Mountain (Vic.)\n24\nMount Stirling (Vic.)\n25\nBen Lomond Ski Field (Tas.)\n26\nCradle Valley (Tas.)\n27\nGreat Lake Area (Tas.)\n28\nMount Field Ski Field (Tas.)\n29\nFigure 1 Alpine areas\nFigure Notes\nThis map is approximate only and altitude above Australian Height Datum must be used to determine whether the building falls into an alpine area region.","g":"/ncc/definitions/alpine-area"},{"c":"Definition","t":"Alteration","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_afa20f7c-f191-4f45-9814-435c25979f17","x":"In relation to a building, includes an addition or extension to a building.","g":"/ncc/definitions/alteration"},{"c":"Definition","t":"Aluminium Composite Panel (ACP)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_683cebe4-06c4-4632-9970-aa92bb0b3789","x":"Flat or profiled aluminium sheet material in composite with any type of materials.\nACP","g":"/ncc/definitions/aluminium-composite-panel-acp"},{"c":"Definition","t":"Amenity","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_905252bf-2ff1-43f8-ae81-2949aa116fee","x":"An attribute which contributes to the health, physical independence, comfort and well-being of people.","g":"/ncc/definitions/amenity"},{"c":"Definition","t":"Ancillary components","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_5802c469-ebd4-4cd4-9b70-087839ae099e","x":"A component of the building that is not required to ensure the stability of the building or structure as a whole (that is, not part of the primary structure), but which must still withstand all actions.","g":"/ncc/definitions/ancillary-components"},{"c":"Definition","t":"Ancillary element","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_fec67a07-94b7-4dcf-af88-708eb8864ba7","x":"An element that is secondary to and not an integral part of another element to which it is attached.","g":"/ncc/definitions/ancillary-element"},{"c":"Definition","t":"Annual exceedance probability","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_74a0923e-1a7a-4396-a7ae-50c537bdfe8d","x":"The probability that a given rainfall total accumulated over a given duration will be exceeded in any one year.","g":"/ncc/definitions/annual-exceedance-probability"},{"c":"Definition","t":"Annual greenhouse gas emissions","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_eea4a10f-c51b-47b3-ab0b-72043e96d6c8","x":"The theoretical amount of greenhouse gas emissions attributable to the energy used annually by a building's services, excluding kitchen exhaust and the like.","g":"/ncc/definitions/annual-greenhouse-gas-emissions"},{"c":"Definition","t":"Appropriate authority","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_d102aa06-a2a6-48bb-a79f-d32cfc285636","x":"For the purposes of the Fire Safety Verification Method, means the relevant authority with the statutory responsibility to determine the particular matter satisfies the relevant Performance Requirement.","g":"/ncc/definitions/appropriate-authority"},{"c":"Definition","t":"Appropriate authority","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_c1612e09-903f-47de-9ee0-00fb915ae751","x":"The relevant authority with the statutory responsibility to determine the particular matter.","g":"/ncc/definitions/appropriate-authority-2"},{"c":"Definition","t":"Appropriately qualified person","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_9e4999fb-b4a7-4a5c-b131-73375557b456","x":"A person recognised by the appropriate authority as having qualifications and/or experience in the relevant discipline in question.","g":"/ncc/definitions/appropriately-qualified-person"},{"c":"Definition","t":"Approved disposal system","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_9d2e065b-aa41-45f9-b2f5-4628d8fa28d0","x":"A system for the disposal of sewage, sullage or stormwater approved by an authority having jurisdiction.","g":"/ncc/definitions/approved-disposal-system"},{"c":"Definition","t":"Articulated masonry","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_70407bc9-3de1-449e-828f-62763926b912","x":"Masonry construction in which special provisions have been made for movement by articulation.","g":"/ncc/definitions/articulated-masonry"},{"c":"Definition","t":"Assembly building","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_367d20c3-85f7-45e8-ad37-bba3e069f07d","x":"A building where people may assemble for—\ncivic, theatrical, social, political or religious purposes including a library, theatre, public hall or place of worship; or\neducational purposes in a school, early childhood centre, preschool, or the like; or\nentertainment, recreational or sporting purposes including—\na discotheque, nightclub or a bar area of a hotel or motel providing live entertainment or containing a dance floor; or\na cinema; or\na sports stadium, sporting or other club; or\ntransit purposes including a bus station, railway station, airport or ferry terminal.","g":"/ncc/definitions/assembly-building"},{"c":"Definition","t":"Assessment Method","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_03d9f279-5dcb-4768-81fe-973e4baf55df","x":"A method that can be used for determining that a Performance Solution or Deemed-to-Satisfy Solution complies with the Performance Requirements.","g":"/ncc/definitions/assessment-method"},{"c":"Definition","t":"Assumed cooling thermostat set point","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_0f192202-f406-4ef7-8e1b-2a1a9eb05f8d","x":"The cooling thermostat set point used to calculate cooling degree hours, and equal to [formula] , where [formula] is the mean January outdoor air temperature measured in degrees Celsius.","g":"/ncc/definitions/assumed-cooling-thermostat-set-point"},{"c":"Definition","t":"Atrium","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_d0042ee6-21cd-4d8c-8873-d8bfb694ceff","x":"A space within a building that connects 2 or more storeys and—\nis enclosed at the top by a floor or roof (including a glazed roof structure); and\nincludes any adjacent part of the building not separated by an appropriate barrier to fire; but\ndoes not include a stairwell, rampwell or the space within a shaft; and\nfor the purposes of (a) a space is considered enclosed if the area of the enclosing floor or roof is greater than 50% of the area of the space, measured in plan, of any of the storeys connected by the space.","g":"/ncc/definitions/atrium"},{"c":"Definition","t":"Atrium well","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_b070feb5-d14e-4f94-86a5-f7f95371dc36","x":"A space in an atrium bounded by the perimeter of the openings in the floors or by the perimeter of the floors and the external walls.","g":"/ncc/definitions/atrium-well"},{"c":"Definition","t":"Auditorium (NSW)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_29badeb5-89c1-45af-a10d-fb25847d52c3","x":"A part of an entertainment venue used or intended to be used for the purposes of accommodating an audience to an entertainment.","g":"/ncc/definitions/auditorium-nsw"},{"c":"Definition","t":"Automatic","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_ac370c9b-7389-4daa-ac5b-338e11dc43e7","x":"Designed to operate when activated by a heat, smoke or fire sensing device.","g":"/ncc/definitions/automatic"},{"c":"Definition","t":"Available safe egress time (ASET)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_886716b9-ce16-4752-bcf0-1f0e937ba608","x":"The time between ignition of a fire and the onset of untenable conditions in a specific part of a building.\nThe time referred to in (1) is the calculated interval between the time of ignition of a fire and the time at which conditions become such that the occupant is unable to take effective action to escape to a place of safety.\nASET","g":"/ncc/definitions/available-safe-egress-time-aset"},{"c":"Definition","t":"Average daylight factor","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_bfa93a83-2803-4b7d-a1fe-932fb97c6827","x":"The ratio of the illumination level within a room provided by daylight to the level of daylight outside the building during overcast conditions.","g":"/ncc/definitions/average-daylight-factor"},{"c":"Definition","t":"Average specific extinction area","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_279816f7-f5fd-4c07-aab8-9c951ac56b00","x":"The average specific extinction area for smoke as determined by AS 5637.1.","g":"/ncc/definitions/average-specific-extinction-area"},{"c":"Definition","t":"Backflow prevention device","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_0fd1c6f9-50b2-4e0c-bda6-25c2bf33379f","x":"An air gap, break tank or mechanical device that is designed to prevent the unplanned reversal of flow of water or contaminants into the water service or a Network Utility Operator’s water supply.","g":"/ncc/definitions/backflow-prevention-device"},{"c":"Definition","t":"Backpressure","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_1557cbf1-ca47-4181-b6c6-49b694d0392c","x":"A reversal of water flow caused by the downstream pressure becoming greater than the supply pressure.","g":"/ncc/definitions/backpressure"},{"c":"Definition","t":"Backsiphonage","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_555bfec9-1eb9-4598-b60d-9205b6740a81","x":"A reversal of flow of water caused by negative pressure in the distributing pipes of a water service or supply.","g":"/ncc/definitions/backsiphonage"},{"c":"Definition","t":"Backstage","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_a664353a-ef5b-4cd2-b68b-f2db1db81dce","x":"A space associated with, and adjacent to, a stage in a Class 9b building for scenery, props, equipment, dressing rooms, or the like.","g":"/ncc/definitions/backstage"},{"c":"Definition","t":"Battery system","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_46e7cb4d-2d98-4c13-a599-e2617bb09f0c","x":"One or more chemical cells connected in series, parallel or a combination of the two for the purpose of electrical energy storage.","g":"/ncc/definitions/battery-system"},{"c":"Definition","t":"Blockage","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_417d94d8-f254-4788-9a14-c4c5da89daa6","x":"An obstruction within a water service or sanitary plumbing or drainage system.","g":"/ncc/definitions/blockage"},{"c":"Definition","t":"Boiler","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_5e4c02dd-0737-47ed-ad7b-5de888c05ed7","x":"A vessel or an arrangement of vessels and interconnecting parts, wherein steam or other vapour is generated, or water or other liquid is heated at a pressure above that of the atmosphere, by the application of fire, the products of combustion, electrical power, or similar high temperature means, and—\nincludes superheaters, reheaters, economisers, boiler piping, supports, mountings, valves, gauges, fittings, controls, the boiler settings and directly associated equipment; but\nexcludes a fully flooded or pressurised system where water or other liquid is heated to a temperature lower than the normal atmospheric boiling temperature of the liquid.","g":"/ncc/definitions/boiler"},{"c":"Definition","t":"Bond breaker","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_ca63ce08-6baa-457f-89f2-baac687e148e","x":"A material used as part of a waterproofing system that prevents the membrane bonding to the substrate, bedding or lining.","g":"/ncc/definitions/bond-breaker"},{"c":"Definition","t":"Breaking surf","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_835c2aad-12c4-43af-bb4d-d3f8bcb6acee","x":"Any area of salt water in which waves break on an average of at least 4 days per week but does not include white caps or choppy water.","g":"/ncc/definitions/breaking-surf"},{"c":"Table 2","t":"Building complexity level","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_6bcb5000-6a89-4b08-b8c0-29e79cb105d2","x":"Building complexity level | Criteria\nLow | The building meets only one of the following building complexity criteria: (a) (Attributes), (b) (Class 2), (c) (Occupant numbers) or (d) (Occupant characteristics)\nMedium | The building meets two of the following building complexity criteria: (a) (Attributes), (b) (Class 2), (c) (Occupant numbers) or (d) (Occupant characteristics)\nHigh | The building meets three of the following building complexity criteria: (a) (Attributes), (b) (Class 2), (c) (Occupant numbers) or (d) (Occupant characteristics)\nVery high | The building meets all of the following building complexity criteria: (a) (Attributes), (b) (Class 2), (c) (Occupant numbers) and (d) (Occupant characteristics); or (e) (Building Importance Level 4 or 5)","g":"/ncc/table-2"},{"c":"Definition","t":"Building complexity criteria","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_0fef5840-248c-427a-8e47-85b3203bf0ba","x":"Are used to determine the building complexity level of all or part of a building in accordance with Table 2, where building complexity criteria are as follows:\nAttributes — the building is designed or constructed with any of the following sub-criteria:\nAn effective height of more than 25 m.\nOne or more Performance Solutions are used to demonstrate compliance with the Performance Requirements relating to material and systems for structural safety.\nOne or more Performance Solutions are used to demonstrate compliance with the Performance Requirements relating to material and systems for fire safety.\nIs located in an area prone to natural disaster or adverse environmental conditions.\nClass 2 — all or part of the building is Class 2 of three or more storeys.\nOccupant numbers — the building is to be occupied by more than 100 people determined in accordance with D2D18.\nOccupant characteristics — the building is to be occupied by more than 10 people who will require assistance to evacuate the building in an emergency.\nImportance Level — the building is determined to be Importance Level 4 or 5.\nNotes\nThe NCC currently does not include corresponding technical requirements relating to the defined term ‘building complexity criteria’ and the various building complexity levels. It is intended that these terms will be integrated into future editions of the NCC.\nTable 2 Building complexity level\nBuilding complexity level\nCriteria\nLow\nThe building meets only one of the following building complexity criteria: (a) (Attributes), (b) (Class 2), (c) (Occupant numbers) or (d) (Occupant characteristics)\nMedium\nThe building meets two of the following building complexity criteria: (a) (Attributes), (b) (Class 2), (c) (Occupant numbers) or (d) (Occupant characteristics)\nHigh\nThe building meets three of the following building complexity criteria: (a) (Attributes), (b) (Class 2), (c) (Occupant numbers) or (d) (Occupant characteristics)\nVery high\nThe building meets all of the following building complexity criteria: (a) (Attributes), (b) (Class 2), (c) (Occupant numbers) and (d) (Occupant characteristics); or (e) (Building Importance Level 4 or 5)","g":"/ncc/definitions/building-complexity-criteria"},{"c":"Definition","t":"Buried rainwater tank","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_8535fd90-5dab-4247-83df-54d8cecaf17c","x":"A rainwater tank that is set into and completely covered by earth.","g":"/ncc/definitions/buried-rainwater-tank"},{"c":"Definition","t":"Burnout","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_0d369131-bf6b-47d6-a47d-c3a560c4aef9","x":"Exposure to fire for a time that includes fire growth, full development, and decay in the absence of intervention or automatic suppression, beyond which the fire is no longer a threat to building elements intended to perform load bearing or fire separation functions, or both.","g":"/ncc/definitions/burnout"},{"c":"Definition","t":"Brush fence (SA)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_58e3e6ab-77d3-470e-97bb-e60f6ed299d3","x":"A fence or gate that is primarily constructed of Broombrush (Melalueca Uncinata).","g":"/ncc/definitions/brush-fence-sa"},{"c":"Definition","t":"Bulk grain storage facility (SA)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_0ea6e30e-b7ce-4b3d-ab37-7888621a4eac","x":"A building or structure used for the commercial bulk handling or storage of granular materials such as grain, ore, or the like, where only a small number of occupants are present at one time and includes cell type silos and storage sheds.","g":"/ncc/definitions/bulk-grain-storage-facility-sa"},{"c":"Definition","t":"Carpark","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_1b0c2237-d3d4-4981-97b8-209936e55520","x":"A building that is used for the parking of motor vehicles but is neither a private garage nor used for the servicing of vehicles, other than washing, cleaning or polishing.","g":"/ncc/definitions/carpark"},{"c":"Definition","t":"Cavity","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_d9f8479e-3794-41cf-ab60-e1588241810e","x":"A void between 2 leaves of masonry, or a void between the cladding and the supporting frame, the primary insulation layer or the outermost control layer.","g":"/ncc/definitions/cavity"},{"c":"Definition","t":"Cavity wall","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_a8edd309-0def-4f2d-b71e-ab40c80e2ed8","x":"For the purposes of F1V1 and H2V1, a wall that incorporates a drained cavity.","g":"/ncc/definitions/cavity-wall"},{"c":"Definition","t":"Cell type silo (SA)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_77fc5383-ae28-4bfd-ad12-0d5735cf1366","x":"A type of bulk grain storage facility similar to that illustrated in diagram (a) of Figure SA 1.","g":"/ncc/definitions/cell-type-silo-sa"},{"c":"Definition","t":"Centre-based care class 4 facility (TAS)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_db156553-d9c4-42cf-a5d7-8b78162cf4a9","x":"A facility as defined in Centre Based Care Class 4 Standards.","g":"/ncc/definitions/centre-based-care-class-4-facility-tas"},{"c":"Definition","t":"Centre-based care class 5 facility (TAS)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_28b878a4-8d4f-4303-81b9-7fe24e02aa9c","x":"A facility as defined in Centre Based Care Class 5 Standards.","g":"/ncc/definitions/centre-based-care-class-5-facility-tas"},{"c":"Definition","t":"Certificate of Accreditation","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_e0bb816d-b1a0-4141-8e40-aeb49890b8c6","x":"A certificate issued by a State or Territory accreditation authority stating that the properties and performance of a building material or method of construction or design fulfil specific requirements of the NCC.","g":"/ncc/definitions/certificate-of-accreditation"},{"c":"Definition","t":"Certificate of Conformity","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_8f83f16d-cb22-42b1-ac63-0e3bf17c9d8e","x":"A certificate issued under the ABCB scheme for products and systems certification stating that the properties and performance of a building material or method of construction or design fulfil specific requirements of the NCC.","g":"/ncc/definitions/certificate-of-conformity"},{"c":"Definition","t":"Certification body","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_ffba313b-b83b-4b0f-8d02-42a297581160","x":"A person or organisation operating in the field of material, product, form of construction or design certification that has been accredited by the Joint Accreditation System of Australia and New Zealand (JAS-ANZ), and is accredited for a purpose other than as part of the CodeMark Australia Certification Scheme or WaterMark Certification Scheme.","g":"/ncc/definitions/certification-body"},{"c":"Definition","t":"Characteristic","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_317f6583-7891-4767-92f9-67cf2bf15d6e","x":"The occupant data to be used in the modelling of access solutions which define how an occupant interacts with a building, i.e. occupant movement speeds, turning ability, reach capability, perception of luminance contrast and hearing threshold.","g":"/ncc/definitions/characteristic"},{"c":"Definition","t":"Children’s room (VIC)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_1856d29f-7649-45dd-8439-d52fd65d03a4","x":"a room used exclusively for the care or education of children while the children are attending the service, but does not include a toilet, a kitchen, an administration room or any other ancillary area.","g":"/ncc/definitions/children-s-room-vic"},{"c":"Definition","t":"Clad frame","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_80de9a18-766e-4b0d-a65d-b3873d72f4b2","x":"Timber or metal frame construction with exterior timber or sheet wall cladding that is not sensitive to minor movement and includes substructure masonry walls up to 1.5 m high.","g":"/ncc/definitions/clad-frame"},{"c":"Definition","t":"Climate specific part load value","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_fc66c3e7-45c3-4184-96c8-b34170b296d8","x":"A metric for the efficiency of a connected group of chillers that accounts for the Energy Efficiency Ratio of the chillers operating to meet the design load and specified part-load ratios.","g":"/ncc/definitions/climate-specific-part-load-value"},{"c":"Table 3","t":"Climate zones for thermal design","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_a7a2b893-b7c3-40e1-aa63-5904af8a9a26","x":"State | Location | Climate zone\nACT | Canberra | 7\nNSW | Albury | 4\nNSW | Armidale | 7\nNSW | Batemans Bay | 6\nNSW | Bathurst | 7\nNSW | Bega | 6\nNSW | Bellingen Shire - Dorrigo Plateau | 7\nNSW | Bellingen Shire - Valley & seaboard | 2\nNSW | Bourke | 4\nNSW | Broken Hill | 4\nNSW | Byron Bay | 2\nNSW | Cobar | 4\nNSW | Coffs Harbour | 2\nNSW | Dubbo | 4\nNSW | Goulburn | 7\nNSW | Grafton | 2\nNSW | Griffith | 4\nNSW | Ivanhoe | 4\nNSW | Lismore | 2\nNSW | Lord Howe Island | 2\nNSW | Moree | 4\nNSW | Newcastle | 5\nNSW | Nowra | 6\nNSW | Orange | 7\nNSW | Perisher - Smiggins | 8\nNSW | Port Macquarie | 5\nNSW | Sydney East | 5\nNSW | Sydney West | 6\nNSW | Tamworth | 4\nNSW | Thredbo | 8\nNSW | Wagga Wagga | 4\nNSW | Williamtown | 5\nNSW | Wollongong | 5\nNSW | Yass | 6\nNT | Alice Springs | 3\nNT | Darwin | 1\nNT | Elliot | 3\nNT | Katherine | 1\nNT | Renner Springs | 3\nNT | Tennant Creek | 3\nQLD | Birdsville | 3\nQLD | Brisbane | 2\nQLD | Bundaberg | 2\nQLD | Cairns | 1\nQLD | Cooktown | 1\nQLD | Cunnamulla | 3\nQLD | Gladstone | 2\nQLD | Hervey Bay | 2\nQLD | Hughenden | 3\nQLD | Longreach | 3\nQLD | Mackay | 2\nQLD | Mount Isa | 3\nQLD | Normanton | 1\nQLD | Rockhampton | 2\nQLD | Roma | 3\nQLD | Southport | 2\nQLD | Toowoomba | 5\nQLD | Townsville | 1\nQLD | Warwick | 5\nQLD | Weipa | 1\nSA | Adelaide | 5\nSA | Bordertown | 6\nSA | Ceduna | 5\nSA | Cook | 4\nSA | Elliston | 5\nSA | Kingscote | 6\nSA | Leigh Creek | 5\nSA | Lobethal | 6\nSA | Loxton | 5\nSA | Naracoorte | 6\nSA | Marree | 4\nSA | Mount Gambier | 6\nSA | Murray Bridge | 6\nSA | Oodnadatta | 4\nSA | Port Augusta | 4\nSA | Port Lincoln | 5\nSA | Renmark | 5\nSA | Tarcoola | 4\nSA | Victor Harbour | 6\nSA | Whyalla | 4\nTAS | Burnie | 7\nTAS | Bicheno | 7\nTAS | Deloraine | 7\nTAS | Devonport | 7\nTAS | Flinders Island | 7\nTAS | Hobart | 7\nTAS | Huonville | 7\nTAS | King Island | 7\nTAS | Launceston | 7\nTAS | New Norfolk | 7\nTAS | Oatlands | 7\nTAS | Orford | 7\nTAS | Rossarden | 7\nTAS | Smithton | 7\nTAS | St Marys | 7\nTAS | Zeehan | 7\nVIC | Anglesea | 6\nVIC | Ararat | 7\nVIC | Bairnsdale | 6\nVIC | Ballarat | 7\nVIC | Benalla | 6\nVIC | Bendigo | 6\nVIC | Bright | 7\nVIC | Colac | 6\nVIC | Dandenong | 6\nVIC | Echuca | 4\nVIC | Geelong | 6\nVIC | Hamilton | 7\nVIC | Horsham | 6\nVIC | Melbourne | 6\nVIC | Mildura | 4\nVIC | Portland | 6\nVIC | Sale | 6\nVIC | Shepparton | 4\nVIC | Swan Hill | 4\nVIC | Traralgon | 6\nVIC | Wangaratta | 7\nVIC | Warrnambool | 6\nVIC | Wodonga | 6\nWA | Albany | 6\nWA | Balladonia | 4\nWA | Broome | 1\nWA | Bunbury | 5\nWA | Carnarvon | 3\nWA | Christmas Island | 1\nWA | Cocos Island | 1\nWA | Derby | 1\nWA | Esperance | 5\nWA | Exmouth | 1\nWA | Geraldton | 5\nWA | Halls Creek | 3\nWA | Kalgoorlie-Boulder | 4\nWA | Karratha | 1\nWA | Meekatharra | 4\nWA | Northam | 4\nWA | Pemberton | 6\nWA | Perth | 5\nWA | Port Hedland | 1\nWA | Wagin | 4\nWA | Wyndham | 1","g":"/ncc/table-3"},{"c":"Definition","t":"Climate zone","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_0d25cef7-0651-40ea-a0e6-3d3db1191e24","x":"An area defined in Figure 2 and in Table 3 for specific locations, having energy efficiency provisions based on a range of similar climatic characteristics.\nTable 3 Climate zones for thermal design\nState\nLocation\nClimate zone\nACT\nCanberra\n7\nNSW\nAlbury\n4\nNSW\nArmidale\n7\nNSW\nBatemans Bay\n6\nNSW\nBathurst\n7\nNSW\nBega\n6\nNSW\nBellingen Shire - Dorrigo Plateau\n7\nNSW\nBellingen Shire - Valley & seaboard\n2\nNSW\nBourke\n4\nNSW\nBroken Hill\n4\nNSW\nByron Bay\n2\nNSW\nCobar\n4\nNSW\nCoffs Harbour\n2\nNSW\nDubbo\n4\nNSW\nGoulburn\n7\nNSW\nGrafton\n2\nNSW\nGriffith\n4\nNSW\nIvanhoe\n4\nNSW\nLismore\n2\nNSW\nLord Howe Island\n2\nNSW\nMoree\n4\nNSW\nNewcastle\n5\nNSW\nNowra\n6\nNSW\nOrange\n7\nNSW\nPerisher - Smiggins\n8\nNSW\nPort Macquarie\n5\nNSW\nSydney East\n5\nNSW\nSydney West\n6\nNSW\nTamworth\n4\nNSW\nThredbo\n8\nNSW\nWagga Wagga\n4\nNSW\nWilliamtown\n5\nNSW\nWollongong\n5\nNSW\nYass\n6\nNT\nAlice Springs\n3\nNT\nDarwin\n1\nNT\nElliot\n3\nNT\nKatherine\n1\nNT\nRenner Springs\n3\nNT\nTennant Creek\n3\nQLD\nBirdsville\n3\nQLD\nBrisbane\n2\nQLD\nBundaberg\n2\nQLD\nCairns\n1\nQLD\nCooktown\n1\nQLD\nCunnamulla\n3\nQLD\nGladstone\n2\nQLD\nHervey Bay\n2\nQLD\nHughenden\n3\nQLD\nLongreach\n3\nQLD\nMackay\n2\nQLD\nMount Isa\n3\nQLD\nNormanton\n1\nQLD\nRockhampton\n2\nQLD\nRoma\n3\nQLD\nSouthport\n2\nQLD\nToowoomba\n5\nQLD\nTownsville\n1\nQLD\nWarwick\n5\nQLD\nWeipa\n1\nSA\nAdelaide\n5\nSA\nBordertown\n6\nSA\nCeduna\n5\nSA\nCook\n4\nSA\nElliston\n5\nSA\nKingscote\n6\nSA\nLeigh Creek\n5\nSA\nLobethal\n6\nSA\nLoxton\n5\nSA\nNaracoorte\n6\nSA\nMarree\n4\nSA\nMount Gambier\n6\nSA\nMurray Bridge\n6\nSA\nOodnadatta\n4\nSA\nPort Augusta\n4\nSA\nPort Lincoln\n5\nSA\nRenmark\n5\nSA\nTarcoola\n4\nSA\nVictor Harbour\n6\nSA\nWhyalla\n4\nTAS\nBurnie\n7\nTAS\nBicheno\n7\nTAS\nDeloraine\n7\nTAS\nDevonport\n7\nTAS\nFlinders Island\n7\nTAS\nHobart\n7\nTAS\nHuonville\n7\nTAS\nKing Island\n7\nTAS\nLaunceston\n7\nTAS\nNew Norfolk\n7\nTAS\nOatlands\n7\nTAS\nOrford\n7\nTAS\nRossarden\n7\nTAS\nSmithton\n7\nTAS\nSt Marys\n7\nTAS\nZeehan\n7\nVIC\nAnglesea\n6\nVIC\nArarat\n7\nVIC\nBairnsdale\n6\nVIC\nBallarat\n7\nVIC\nBenalla\n6\nVIC\nBendigo\n6\nVIC\nBright\n7\nVIC\nColac\n6\nVIC\nDandenong\n6\nVIC\nEchuca\n4\nVIC\nGeelong\n6\nVIC\nHamilton\n7\nVIC\nHorsham\n6\nVIC\nMelbourne\n6\nVIC\nMildura\n4\nVIC\nPortland\n6\nVIC\nSale\n6\nVIC\nShepparton\n4\nVIC\nSwan Hill\n4\nVIC\nTraralgon\n6\nVIC\nWangaratta\n7\nVIC\nWarrnambool\n6\nVIC\nWodonga\n6\nWA\nAlbany\n6\nWA\nBalladonia\n4\nWA\nBroome\n1\nWA\nBunbury\n5\nWA\nCarnarvon\n3\nWA\nChristmas Island\n1\nWA\nCocos Island\n1\nWA\nDerby\n1\nWA\nEsperance\n5\nWA\nExmouth\n1\nWA\nGeraldton\n5\nWA\nHalls Creek\n3\nWA\nKalgoorlie-Boulder\n4\nWA\nKarratha\n1\nWA\nMeekatharra\n4\nWA\nNortham\n4\nWA\nPemberton\n6\nWA\nPerth\n5\nWA\nPort Hedland\n1\nWA\nWagin\n4\nWA\nWyndham\n1\nFigure 2 Climate zones for thermal design\nFigure Notes\nThis map can be viewed in enlargeable form on the ABCB website at abcb.gov.au.\nA Zone 4 area in South Australia, other than a council area, at an altitude greater than 300 m above the Australian Height Datum is to be considered as Zone 5.\nThe areas referred to in (2) have been defined in an enlarged format on the following maps produced by the Department of Planning, Transport and Infrastructure (these maps can be viewed on the Government of South Australia website at www.sa.gov.au):\nAdelaide Hills Climate Zone Map.\nBarossa Council Climate Zone Map.\nRegional Council of Goyder Climate Zone Map.\nLocations in climate zone 8 are in alpine areas.","g":"/ncc/definitions/climate-zone"},{"c":"Definition","t":"Collected","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_e14fe7c6-ad26-4297-b38c-0cc6e9f6f3d0","x":"For the purposes of Section F in NCC Volume One, the interception of water —\non the surface or sub-surface of a building element; or\non an allotment; or\non a site; or\nresulting from sitework.","g":"/ncc/definitions/collected"},{"c":"Definition","t":"Combustible","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_a7b1bb43-dc94-41fb-9e49-6a37f0d6b236","x":"Applied to—\na material — means combustible as determined by an Accredited Testing Laboratory in accordance with AS 1530.1; and\nconstruction or part of a building — means constructed wholly or in part of combustible materials.\nNotes\nUntil the adoption of the next edition of the NCC, determination need not be undertaken by an Accredited Testing Laboratory.","g":"/ncc/definitions/combustible"},{"c":"Definition","t":"Combustible cladding product (VIC)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_3ebc9718-abb3-45bb-bf7f-778d775e74ab","x":"Means—\naluminium composite panels (ACPs) with a core of less than 93% inert mineral filler (inert content) by mass in external cladding as part of a wall system; and\nexpanded polystyrene (EPS) products used in an external insulation and finish (rendered) wall system.","g":"/ncc/definitions/combustible-cladding-product-vic"},{"c":"Definition","t":"Common wall","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_10ec47a6-8c03-45a1-81b3-6e52c6d081b9","x":"For the purposes of—\nVolume One, a wall that is common to adjoining buildings.\nVolume Two and the ABCB Housing Provisions, a wall that is common to adjoining buildings other than Class 1 buildings.","g":"/ncc/definitions/common-wall"},{"c":"Definition","t":"Condensation","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_7bd3fe3a-8528-4438-a6cb-6f4b43993774","x":"The formation of liquid water on the surface of a building element or material as a result of moist air coming into contact with a surface which is at a lower temperature.","g":"/ncc/definitions/condensation"},{"c":"Definition","t":"Conditioned space","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_26276791-20ad-4404-951f-29b5bff0ff80","x":"For the purposes of—\nVolume One, a space within a building, including a ceiling or under-floor supply air plenum or return air plenum, where the environment is likely, by the intended use of the space, to have its temperature controlled by air-conditioning; or\nVolume Two and the ABCB Housing Provisions, a space within a building that is heated or cooled by the building’s domestic services, excluding a non-habitable room in which a heater with a capacity of not more than 1.2 kW or 4.3 MJ/hour is installed.","g":"/ncc/definitions/conditioned-space"},{"c":"Definition","t":"Construction activity actions","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_4e175463-ff1e-4a03-aa61-1375cc138674","x":"Actions due to stacking of building materials or the use of equipment, including cranes and trucks, during construction or actions which may be induced by floor to floor propping.","g":"/ncc/definitions/construction-activity-actions"},{"c":"Definition","t":"Containment protection","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_f80df168-6569-4558-86ed-6d4b94202ea0","x":"The installation of a backflow prevention device at the point of connection of a Network Utility Operator’s water supply to a site.","g":"/ncc/definitions/containment-protection"},{"c":"Definition","t":"Contaminant","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_a7483c3c-cd8a-4c37-8f2b-8e4fba0e0989","x":"Any substance (including gases, liquids, solids or micro-organisms), energy (excluding noise) or heat, that either by itself or in combination with the same, similar or other substances, energy or heat, changes or is likely to change the physical, chemical or biological condition of water.","g":"/ncc/definitions/contaminant"},{"c":"Definition","t":"Continental seating (NSW)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_36744376-22a3-4d9c-a85c-7559385382c8","x":"Rows of seating in which the rows extend the full width of an auditorium without intervening aisles.","g":"/ncc/definitions/continental-seating-nsw"},{"c":"Definition","t":"Control layer","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_e53cf170-3a1e-49b9-942d-76571f407ccc","x":"Any continuous layer that is installed for one or more of the purposes of air, water, vapour or thermal control, including pliable building membrane and sarking-type material but excluding waterproofing membranes or the like complying with AS/NZS 4858.","g":"/ncc/definitions/control-layer"},{"c":"Definition","t":"Controlled fill","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_1f98b7e6-c1c3-4502-aa14-29cd7f1f4314","x":"Material that has been placed and compacted in layers with compaction equipment (such as a vibrating plate) within a defined moisture range to a defined density requirement.","g":"/ncc/definitions/controlled-fill"},{"c":"Definition","t":"Cooling degree hours","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_321d45d7-fb05-4379-9994-48b8241d1042","x":"For any one hour when the mean outdoor air temperature is above the assumed cooling thermostat set point, the degree Celsius air temperature difference between the mean outdoor air temperature and the assumed cooling thermostat set point.","g":"/ncc/definitions/cooling-degree-hours"},{"c":"Definition","t":"Cooling load","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_472a0fb8-883e-4d81-8175-ccc758fa911f","x":"The calculated amount of energy removed from the cooled spaces of the building annually by artificial means to maintain the desired temperatures in those spaces.","g":"/ncc/definitions/cooling-load"},{"c":"Definition","t":"Critical radiant flux (CRF)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_a79820ca-7f44-4362-bffa-251cb62fd2c3","x":"The critical heat flux at extinguishment (CHF in kW/m2) as determined by an Accredited Testing Laboratory in accordance with AS ISO 9239.1.\nNotes\nUntil the adoption of the next edition of the NCC, determination need not be undertaken by an Accredited Testing Laboratory.\nCRF","g":"/ncc/definitions/critical-radiant-flux-crf"},{"c":"Definition","t":"Cross-connection","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_b3f409ec-8f72-48d9-8a64-0dc9d5fb5d67","x":"Any actual or potential connection between a water supply and any contaminant.","g":"/ncc/definitions/cross-connection"},{"c":"Definition","t":"Cross-over (NSW)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_6d91f1ea-c7bb-441e-b4e8-d85118b6c8fd","x":"In relation to an entertainment venue or temporary structure, means a walkway between aisles or between an aisle and an egress doorway.","g":"/ncc/definitions/cross-over-nsw"},{"c":"Definition","t":"Curtain wall","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_49bd866d-0008-4065-b48d-068425109156","x":"A non-load bearing external wall that is not a panel wall.","g":"/ncc/definitions/curtain-wall"},{"c":"Definition","t":"Daily outdoor temperature range","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_862e013f-fbc9-4e65-a6ad-087b28a4a9cd","x":"The difference between the maximum and minimum temperatures that occur in a day.","g":"/ncc/definitions/daily-outdoor-temperature-range"},{"c":"Definition","t":"Damp-proof course (DPC)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_0d21b1c5-7e4f-446c-99a0-4c7564ed7952","x":"A continuous layer of impervious material placed in a masonry wall or pier, or between a wall or pier and a floor, to prevent the upward or downward migration of water.\nDPC","g":"/ncc/definitions/damp-proof-course-dpc"},{"c":"Definition","t":"Deemed-to-Satisfy Provisions","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_2f02788f-8757-4689-b36e-e44d96524cc9","x":"Provisions which are deemed to satisfy the Performance Requirements.","g":"/ncc/definitions/deemed-to-satisfy-provisions"},{"c":"Definition","t":"Deemed-to-Satisfy Solution","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_6c6aafcc-5734-4b89-8f6b-efe41021e0f5","x":"A method of satisfying the Deemed-to-Satisfy Provisions.","g":"/ncc/definitions/deemed-to-satisfy-solution"},{"c":"Definition","t":"Defined flood event (DFE)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_00dfc76d-904f-48f3-b8bb-7f129961eba2","x":"The flood event selected for the management of flood hazard for the location of specific development as determined by the appropriate authority.\nDFE","g":"/ncc/definitions/defined-flood-event-dfe"},{"c":"Definition","t":"Defined flood level (DFL)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_ba1bb29d-4922-466a-b88a-0521d2e371a6","x":"The flood level associated with a defined flood event relative to a specified datum (see Figure 3).\nFigure 3 Identification of defined flood level, flood hazard level and freeboard\nDFL","g":"/ncc/definitions/defined-flood-level-dfl"},{"c":"Definition","t":"Dehumidification gram hours","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_507495f0-e182-4e06-983b-54d69d688cf6","x":"For any one hour when the mean humidity is more than 15.7g/kg, the grams per kilogram of absolute humidity difference between the mean outdoor absolute humidity and 15.7g/kg.","g":"/ncc/definitions/dehumidification-gram-hours"},{"c":"Definition","t":"Designated bushfire prone area","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_2c223137-7ce5-4993-bd69-503e243c9453","x":"Land which has been designated under a power of legislation as being subject, or likely to be subject, to bushfires.","g":"/ncc/definitions/designated-bushfire-prone-area"},{"c":"Definition","t":"Design bushfire","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_fc7f3ef6-dbba-497f-99fa-f2b705b93110","x":"The characteristics of a bushfire, its initiation, spread and development, which arises from weather conditions, topography and fuel (vegetation) in a given setting, used to determine fire actions.","g":"/ncc/definitions/design-bushfire"},{"c":"Definition","t":"Design fire","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_4caeb2ca-3df3-4360-8306-316b326b08d8","x":"The quantitative description of a representation of a fire within the design scenario.","g":"/ncc/definitions/design-fire"},{"c":"Definition","t":"Design scenario","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_7081833d-1b8f-4583-8988-aaf1fb70801a","x":"The specific scenario of which the sequence of events is quantified and a fire safety engineering analysis is conducted against.","g":"/ncc/definitions/design-scenario"},{"c":"Table 4","t":"Wind classes","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_2d20ac5e-81ea-441c-942e-c0598ba2c6dd","x":"Non-cyclonic Region A and B1 | Cyclonic Region B2, C and D\nN1, N2, N3 | C1\nN4, N5, N6 (these wind classes are covered in the ABCB Housing Provisions Part 2.2). | C2, C3, C4 (these wind classes are covered in the ABCB Housing Provisions Part 2.2).\nTable Notes\nWind classification map identifying wind regions is contained in ABCB Housing Provisions Part 2.2 (see Figure 2.2.3).\nInformation on wind classes for particular areas may be available from the appropriate authority.\n“N” = non-cyclonic winds and “C” = cyclonic winds.","g":"/ncc/table-4"},{"c":"Definition","t":"Design wind speed","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_84fc66d2-9804-4b12-8479-2240c139d62a","x":"The design gust wind speed for the area where the building is located, calculated in accordance with AS/NZS 1170.2 or AS 4055 (see Table 4 for wind classes).\nTable 4 Wind classes\nNon-cyclonic Region A and B1\nCyclonic Region B2, C and D\nN1, N2, N3\nC1\nN4, N5, N6 (these wind classes are covered in the ABCB Housing Provisions Part 2.2).\nC2, C3, C4 (these wind classes are covered in the ABCB Housing Provisions Part 2.2).\nTable Notes\nWind classification map identifying wind regions is contained in ABCB Housing Provisions Part 2.2 (see Figure 2.2.3).\nInformation on wind classes for particular areas may be available from the appropriate authority.\n“N” = non-cyclonic winds and “C” = cyclonic winds.","g":"/ncc/definitions/design-wind-speed"},{"c":"Definition","t":"Detention centre","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_32cca056-7f6e-4135-b2e2-ce403cac23e7","x":"A building in which persons are securely detained by means of the built structure including a prison, remand centre, juvenile detention centre, holding cells or psychiatric detention centre.","g":"/ncc/definitions/detention-centre"},{"c":"Definition","t":"Development consent (NSW)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_79822938-9a59-4c22-bc26-14c3b95334e7","x":"Is as defined in the Environmental Planning and Assessment Act 1979.","g":"/ncc/definitions/development-consent-nsw"},{"c":"Definition","t":"Direct fix cladding wall","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_66f74654-0e14-4b1a-a942-e5b2499d2705","x":"For the purposes of F1V1 and H2V1, means a wall with cladding attached directly to the wall framing without the use of a drained cavity.","g":"/ncc/definitions/direct-fix-cladding-wall"},{"c":"Definition","t":"Discontinuous construction","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_ba34e29d-195b-41f3-8774-cec1cf915aa6","x":"Means—\na wall having a minimum 20 mm cavity between 2 separate leaves, and—\nfor masonry, where wall ties are used to connect leaves, the ties are of the resilient type; and\nfor other than masonry, there is no mechanical linkage between the leaves, except at the periphery; and\na staggered stud wall is not deemed to be discontinuous construction.","g":"/ncc/definitions/discontinuous-construction"},{"c":"Definition","t":"Display glazing","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_28e52516-3950-447f-8092-7aeb6cf3ce0a","x":"Glazing used to display retail goods in a shop or showroom directly adjacent to a walkway or footpath, but not including that used in a café or restaurant.","g":"/ncc/definitions/display-glazing"},{"c":"Definition","t":"Domestic services","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_2d333fe8-f713-4bed-8853-82b0771caf79","x":"The basic engineering systems that use energy or control the use of energy; and—\nincludes—\nheating, air-conditioning, mechanical ventilation and artificial lighting; and\npumps and heaters for swimming pools and spa pools; and\nheated water systems; and\non-site renewable energy equipment; but\nexcludes cooking facilities and portable appliances.","g":"/ncc/definitions/domestic-services"},{"c":"Definition","t":"Drainage","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_25307451-c7e1-4167-b4de-e5a1af26694c","x":"Any part of—\na sanitary drainage system, including any liquid trade waste drainage; or\na stormwater drainage system.","g":"/ncc/definitions/drainage"},{"c":"Definition","t":"Drainage flange","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_2e5370a3-7f80-4486-8af6-4387bbf9acce","x":"A flange connected to a waste pipe, at the point at which it passes through the floor substrate, to prevent leakage and which enables tile bed drainage into the waste pipe.","g":"/ncc/definitions/drainage-flange"},{"c":"Definition","t":"Drainage riser","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_afdcf6a5-e364-4a91-bbc8-47678401204b","x":"A waste pipe between the floor waste and the drainage system.","g":"/ncc/definitions/drainage-riser"},{"c":"Definition","t":"Drainage system","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_8310df67-b7b9-4f62-b022-0655a2ae4428","x":"A system that—\nconveys water by gravity, mechanical means, or evaporation to a point of discharge or evaporative surface; or\nchannels water by pipes, overflows, and overland flow paths to a point of discharge.","g":"/ncc/definitions/drainage-system"},{"c":"Definition","t":"Drained","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_a9b54c0e-e7a8-46bf-89da-e39d0779f9e0","x":"For the purposes of Section F in NCC Volume One, the removal to a drainage system, water that has been collected and redirected.","g":"/ncc/definitions/drained"},{"c":"Definition","t":"Drinking water","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_762d6a54-e28c-400b-b9c5-5fceac019a05","x":"Water intended primarily for human consumption but which has other domestic uses.","g":"/ncc/definitions/drinking-water"},{"c":"Definition","t":"Early childhood centre","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_9ff8fad7-8992-4708-be17-784d962a0530","x":"Any premises or part thereof providing or intending to provide a centre-based education and care service within the meaning of the Education and Care Services National Law Act 2010 (Vic), the Education and Care Services National Regulations and centre-based services that are licensed or approved under State and Territory children's services law, but excludes education and care primarily provided to school aged children in outside school hours settings.","g":"/ncc/definitions/early-childhood-centre"},{"c":"Definition","t":"Effective height","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_cd986c21-bc64-43a9-954d-86e35d335b74","x":"The vertical distance between the floor of the lowest storey included in the calculation of rise in storeys and the floor of the topmost storey (excluding the topmost storey if it contains only heating, ventilating, lift or other equipment, water tanks or similar service units).","g":"/ncc/definitions/effective-height"},{"c":"Definition","t":"Efficacy","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_2e774679-ab79-4817-b344-0ce56a475882","x":"The degree to which a system achieves a design objective given that it performs to a level consistent with the system specification during the relevant fire scenario.","g":"/ncc/definitions/efficacy"},{"c":"Definition","t":"Electricity network substation","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_7a37df1f-0b8b-4b03-94ca-69ea423a363f","x":"A building in which high voltage supply is converted or transformed and which is controlled by a licensed network service provider designated under a power of legislation.","g":"/ncc/definitions/electricity-network-substation"},{"c":"Definition","t":"Electric passenger lift","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_a54661ef-5bbf-436c-ac5a-f928bfac8709","x":"A power-operated lift for raising or lowering people in a car in which the motion of the car is obtained from an electric motor mechanically coupled to the hoisting mechanism.","g":"/ncc/definitions/electric-passenger-lift"},{"c":"Definition","t":"Electrohydraulic passenger lift","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_bfdd9a48-8a52-4c7b-8801-f101a9ec8577","x":"A power-operated lift for raising or lowering people in a car in which the motion of the car is obtained from the action of liquid under pressure acting on a piston or ram, the pressure being generated by a pump driven by an individual electric motor.","g":"/ncc/definitions/electrohydraulic-passenger-lift"},{"c":"Definition","t":"Energy value","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_388e9c95-9236-466e-95b8-ac0bff65dd3d","x":"The net cost to society including, but not limited to, costs to the building user, the environment and energy networks.","g":"/ncc/definitions/energy-value"},{"c":"Definition","t":"Engaged pier","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_bc1dec1c-4159-444e-a96c-3a33f535bf20","x":"A pier bonded to a masonry wall by course bonding of masonry units or by masonry ties.","g":"/ncc/definitions/engaged-pier"},{"c":"Definition","t":"Entertainment venue (NSW)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_410e8de4-5482-4e25-932f-371f1d5d6042","x":"Is as defined in the Environmental Planning and Assessment Regulation 2021.","g":"/ncc/definitions/entertainment-venue-nsw"},{"c":"Definition","t":"Envelope","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_71ea06f9-79ec-4eae-bdf4-d90302f51eb5","x":"For the purposes of—\nSection J and Part F8 in NCC Volume One, the parts of a building’s fabric that separate a conditioned space or habitable room from—\nthe exterior of the building; or\nan internal non-conditioned space where the temperature is primarily determined by external ambient conditions and thermal loads are not addressed by the air-conditioning and ventilation services; or\nPart H6 in NCC Volume Two and Section 10 and Section 13 of the ABCB Housing Provisions, the parts of a building’s fabric that separate artificially heated or cooled spaces from—\nthe exterior of the building; or\nother spaces that are not artificially heated or cooled.","g":"/ncc/definitions/envelope"},{"c":"Definition","t":"Equivalent","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_6a914e67-bc6e-4499-8316-001bc4729a09","x":"Equivalent to the level of health, safety and amenity provided by the Deemed-to-Satisfy Provisions.","g":"/ncc/definitions/equivalent"},{"c":"Definition","t":"Evacuation route","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_dc98ef12-e47e-44ae-abca-010bd3db8c90","x":"The continuous path of travel (including exits, public corridors and the like) from any part of a building, including within a sole-occupancy unit in a Class 2 or 3 building or Class 4 part, to a safe place.","g":"/ncc/definitions/evacuation-route"},{"c":"Definition","t":"Evacuation time","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_2c29c30f-9de7-48fc-a416-7f0c315c9faa","x":"The time calculated from when the emergency starts for the occupants of the building to evacuate to a safe place.","g":"/ncc/definitions/evacuation-time"},{"c":"Definition","t":"Existing building (WA)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_8ac8f8b3-e9b0-42c6-b39c-697e2b9f528f","x":"For the purpose of Part H6, an existing Class 1 building or an existing attached Class 10 part that was not required to comply with the energy efficiency requirements of NCC 2022 or any later edition.","g":"/ncc/definitions/existing-building-wa"},{"c":"Definition","t":"Exit","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_9712f630-8cf7-401b-b1cc-ae0be4485915","x":"Means—\nAny, or any combination of the following if they provide egress to a road or open space:\nAn internal or external stairway.\nA ramp.\nA fire-isolated passageway.\nA doorway opening to a road or open space; or\nA horizontal exit or a fire-isolated passageway leading to a horizontal exit.","g":"/ncc/definitions/exit"},{"c":"Definition","t":"Expert judgement","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_1913e927-f74b-4892-bfc1-18eb299f184b","x":"The judgement of an expert who has the qualifications and experience to determine whether a Performance Solution or Deemed-to-Satisfy Solution complies with the Performance Requirements.","g":"/ncc/definitions/expert-judgement"},{"c":"Definition","t":"External wall","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_d87c7cc0-d0b0-40ab-9a5b-d070ed6e115e","x":"For the purposes of—\nVolume One, an outer wall of a building which is not a common wall; or\nVolume Two, an outer wall of a building which is not a separating wall.","g":"/ncc/definitions/external-wall"},{"c":"Definition","t":"Extra-low voltage","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_97132ee1-60c7-407c-9a1a-f299a7d44070","x":"A voltage not exceeding 50 V AC or 120 V ripple-free DC.","g":"/ncc/definitions/extra-low-voltage"},{"c":"Definition","t":"Fabric","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_13553d4f-118c-47e2-90ba-9892194abdf6","x":"The basic building structural elements and components of a building including the roof, ceilings, walls, glazing and floors.","g":"/ncc/definitions/fabric"},{"c":"Definition","t":"Farm building","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_f68a626d-6a81-4785-95fa-c032c987c28e","x":"A Class 7 or 8 building located on land primarily used for farming —\nthat is—\nused in connection with farming; or\nused primarily to store one or more farm vehicles; or\na combination of (i) and (ii); and\nin which the total number of persons accommodated at any time does not exceed one person per 200 m² of floor area or part thereof, up to a maximum of 8 persons; and\nwith a total floor area of not more than 3500 m².","g":"/ncc/definitions/farm-building"},{"c":"Definition","t":"Farming","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_3a88d307-03ed-4c4e-b323-f4652ce98208","x":"Includes—\ncultivating, propagating and harvesting plants or fungi or their products or parts, including seeds, spores, bulbs or the like, but does not include forestry; or\nmaintaining animals in any physical environment for the purposes of—\nbreeding them; or\nselling them; or\nacquiring and selling their bodily produce such as milk, wool, eggs or the like; or\na combination of (a) and (b),\nbut does not include forestry or maintaining animals for sport or recreational purposes.","g":"/ncc/definitions/farming"},{"c":"Definition","t":"Farm shed","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_9f1c1558-afbd-4a7a-a1b8-ae860e3b2ccd","x":"A single storey Class 7 or 8 building located on land primarily used for farming —\nthat is—\nused in connection with farming; or\nused primarily to store one or more farm vehicles; or\na combination of (i) and (ii); and\noccupied neither frequently nor for extended periods by people; and\nin which the total number of persons accommodated at any time does not exceed 2; and\nwith a total floor area of more than 500 m² but not more than 2000 m².","g":"/ncc/definitions/farm-shed"},{"c":"Definition","t":"Farm vehicle","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_a787e8f7-be9c-4f11-976a-1ba791855c08","x":"A vehicle used in connection with farming.","g":"/ncc/definitions/farm-vehicle"},{"c":"Definition","t":"Film (NSW)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_48e08bfc-2a37-43dd-882f-afc4cc3b5a7c","x":"A cinematograph film of a size of 35 mm or greater.","g":"/ncc/definitions/film-nsw"},{"c":"Definition","t":"Finished ground level","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_8a0dd7f5-e2b1-4d63-8041-541e9efbf108","x":"The ground level adjacent to footing systems at the completion of construction and landscaping.","g":"/ncc/definitions/finished-ground-level"},{"c":"Definition","t":"Fire actions","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_fb2c3401-cb66-4fb9-b2ae-e98a074cd266","x":"Each of the following:\nairborne embers; and\nburning debris and/or accumulated embers adjacent to building elements; and\nheat transfer from combustible materials within the site; and\nradiant heat from a bushfire front; and\nflame contact from a bushfire front; and\nthe period of time post fire front subject to collapsing vegetation due to persistent combustion.","g":"/ncc/definitions/fire-actions"},{"c":"Definition","t":"Fire brigade","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_cc69b717-0915-4071-87d9-176353f8cc9a","x":"A statutory authority constituted under an Act of Parliament having as one of its functions, the protection of life and property from fire and other emergencies.","g":"/ncc/definitions/fire-brigade"},{"c":"Definition","t":"Fire brigade station","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_2017565b-5523-4b4c-b656-ae08d7dcdbfd","x":"For the purposes of E1D2(1)(b) and I3D9, means a state or territory government operated premises which is a station for a fire brigade.","g":"/ncc/definitions/fire-brigade-station"},{"c":"Definition","t":"Fire compartment","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_524b0326-5823-4ddc-9eb3-adab587568e8","x":"Either—\nthe total space of a building; or\nwhen referred to in—\nthe Performance Requirements — any part of a building separated from the remainder by barriers to fire such as walls and/or floors having an appropriate resistance to the spread of fire with any openings adequately protected; or\nthe Deemed-to-Satisfy Provisions — any part of a building separated from the remainder by walls and/or floors each having an FRL not less than that required for a fire wall for that type of construction and where all openings in the separating construction are protected in accordance with the Deemed-to-Satisfy Provisions of the relevant Part.","g":"/ncc/definitions/fire-compartment"},{"c":"Definition","t":"Fire growth","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_dea9be12-2d60-4b2c-b62d-5ec6b7ae9499","x":"The stage of fire development during which the heat release rate and the temperature of the fire are generally increasing.","g":"/ncc/definitions/fire-growth"},{"c":"Definition","t":"Fire hazard","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_7babb9ed-37aa-4441-b7da-93711bfa5283","x":"The danger in terms of potential harm and degree of exposure arising from the start and spread of fire and the smoke and gases that are thereby generated.","g":"/ncc/definitions/fire-hazard"},{"c":"Definition","t":"Fire hazard properties","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_ee8b763a-6571-4acb-83bd-313fd338d141","x":"The following properties of a material or assembly that indicate how they behave under specific fire test conditions:\nCritical radiant flux and smoke development rate, determined in accordance with AS ISO 9239.1.\nSmoke-Developed Index and Spread-of-Flame Index, determined in accordance with AS/NZS 1530.3.\nGroup number, average specific extinction area and Smoke growth rate index (SMOGRARC), determined in accordance with AS 5637.1.","g":"/ncc/definitions/fire-hazard-properties"},{"c":"Definition","t":"Fire intensity","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_7b10d376-72de-4ed5-9262-35f2d1a39ecc","x":"The rate of release of calorific energy in watts, determined either theoretically or empirically, as applicable.","g":"/ncc/definitions/fire-intensity"},{"c":"Definition","t":"Fire-isolated passageway","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_2f0af1de-a7c1-44b9-a8b5-1faaedfdb023","x":"A corridor, hallway or the like, of fire-resisting construction, which provides egress to or from a fire-isolated stairway or fire-isolated ramp or to a road or open space.","g":"/ncc/definitions/fire-isolated-passageway"},{"c":"Definition","t":"Fire-isolated ramp","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_cfa6cc89-aa6c-4eaf-90e6-8aabe04b9c76","x":"A ramp within a fire-resisting enclosure which provides egress from a storey.","g":"/ncc/definitions/fire-isolated-ramp"},{"c":"Definition","t":"Fire-isolated stairway","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_c71e675e-d6e1-4612-8e59-381a56e224a8","x":"A stairway within a fire-resisting shaft and includes the floor and roof or top enclosing structure.","g":"/ncc/definitions/fire-isolated-stairway"},{"c":"Definition","t":"Fire load","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_c6f00a2d-3f92-463d-8e6f-1f215ea421d5","x":"The sum of the net calorific values of the combustible contents which can reasonably be expected to burn within a fire compartment, including furnishings, built-in and removable materials, and building elements.\nNotes\nThe calorific values must be determined at the ambient moisture content or humidity (the unit of measurement is MJ).","g":"/ncc/definitions/fire-load"},{"c":"Definition","t":"Fire-protected timber","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_b999bcb2-7ffd-4512-876a-a30c20b21025","x":"Fire-resisting timber building elements that comply with Specification 10.","g":"/ncc/definitions/fire-protected-timber"},{"c":"Definition","t":"Fire-protective covering","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_e18489e8-9038-4b37-a28f-401776a4aff5","x":"Any one or more of the following:\n13 mm fire-protective grade plasterboard.\n12 mm cellulose cement flat sheeting complying with AS/NZS 2908.2 or ISO 8336.\n12 mm fibrous plaster reinforced with 13 mm x 13 mm x 0.7 mm galvanised steel wire mesh located not more than 6 mm from the exposed face.\nOther material not less fire-protective than 13 mm fire-protective grade plasterboard, fixed in accordance with the normal trade practice for a fire-protective covering.","g":"/ncc/definitions/fire-protective-covering"},{"c":"Definition","t":"Fire-protected steel","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_9498a494-1571-47a6-94ca-1d4bb8f0cbd9","x":"Loadbearing wall construction comprising hot rolled or cold formed steel members protected with a fire-protective covering that consists of—\nnot less than 2 layers of 13 mm fire-protective grade plasterboard applied to each side of the wall; and\nadditional fire-protective covering to that required by (a) where necessary to achieve the FRL required for the wall.","g":"/ncc/definitions/fire-protected-steel"},{"c":"Definition","t":"Fire-resistance level (FRL)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_39cf18d8-259c-4c88-81d5-db7a127feed7","x":"The grading periods in minutes determined in accordance with Specifications 1 and 2, for the following criteria—\nstructural adequacy; and\nintegrity; and\ninsulation,\nand expressed in that order.\nNotes\nA dash means there is no requirement for that criterion. For example, 90/–/– means there is no requirement for an FRL for integrity and insulation, and –/–/– means there is no requirement for an FRL.\nFRL","g":"/ncc/definitions/fire-resistance-level-frl"},{"c":"Definition","t":"Fire-resisting construction","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_882b2e49-ff32-42de-bdf4-2000c9867eaf","x":"For the purposes of Volume One, means one of the Types of construction referred to in Part C2 of Volume One.","g":"/ncc/definitions/fire-resisting-construction"},{"c":"Definition","t":"Fire-resisting","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_2d22acf1-980a-4a51-a1a7-758f41e54a83","x":"For the purposes of—\nVolume One, applied to a building element, having an FRL appropriate for that element; or\nVolume Two, applied to a structural member or other part of a building, having the FRL required for that structural member or other part.","g":"/ncc/definitions/fire-resisting"},{"c":"Definition","t":"Fire safety engineering","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_887de0c1-bac2-4984-b85e-0fbe222d04e5","x":"Application of engineering principles, rules and expert judgement based on a scientific appreciation of the fire phenomenon, often using specific design scenario, of the effects of fire and of the reaction and behaviour of people in order to—\nsave life, protect property and preserve the environment and heritage from destructive fire; and\nquantify the hazards and risk of fire and its effects; and\nmitigate fire damage by proper design, construction, arrangement and use of buildings, materials, structures, industrial processes and transportation systems; and\nevaluate analytically the optimum protective and preventive measures, including design, installation and maintenance of active and passive fire and life safety systems, necessary to limit, within prescribed levels, the consequences of fire.","g":"/ncc/definitions/fire-safety-engineering"},{"c":"Definition","t":"Fire safety system","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_0506eff4-aff6-4610-b001-ba80d4f3b9c7","x":"One or any combination of the methods used in a building to—\nwarn people of an emergency; or\nprovide for safe evacuation; or\nrestrict the spread of fire; or\nextinguish a fire,\nand includes both active and passive systems.","g":"/ncc/definitions/fire-safety-system"},{"c":"Definition","t":"Fire-source feature","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_c8140c52-95f0-42dd-803f-d75a4f92558c","x":"Any one or more of the following:\nThe far boundary of a road, river, lake or the like adjoining the allotment.\nA side or rear boundary of the allotment.\nAn external wall of another building on the allotment which is not a Class 10 building.\nThe construction edge or perimeter of another building on the allotment which is not a Class 10 building and which has a use that constitutes a fire load.","g":"/ncc/definitions/fire-source-feature"},{"c":"Definition","t":"Fire wall","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_0f26abc7-ed98-4bc1-8a36-f3605f035ed5","x":"A wall with an appropriate resistance to the spread of fire that divides a storey or building into fire compartments.","g":"/ncc/definitions/fire-wall"},{"c":"Definition","t":"Fixed wired","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_d699bff1-d598-4cf6-9e6d-776d23aa32ca","x":"For the purposes of Specification 23, a system of electrical wiring (either AC or DC), in which cables are fixed or supported in position.","g":"/ncc/definitions/fixed-wired"},{"c":"Definition","t":"Flammability Index","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_e96b8063-e512-4138-bfeb-d612bb91746d","x":"The index number as determined by an Accredited Testing Laboratory in accordance with AS 1530.2.\nNotes\nUntil the adoption of the next edition of the NCC, determination need not be undertaken by an Accredited Testing Laboratory.","g":"/ncc/definitions/flammability-index"},{"c":"Definition","t":"Flashing","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_f3cdd6b2-0801-4750-ac8b-515dde29def5","x":"A strip or sleeve of impervious material dressed, fitted or built-in to provide a barrier to water movement, or to divert the travel of water, or to cover a joint where water would otherwise penetrate to the interior of a building, and includes the following:\nPerimeter flashing: a flashing used at the floor-wall junction.\nVertical flashing: a flashing used at wall junctions within shower areas.","g":"/ncc/definitions/flashing"},{"c":"Definition","t":"Flashover","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_cb98f75e-99ce-4212-81c9-ac371003b402","x":"In relation to fire hazard properties, means a heat release rate of 1 MW.","g":"/ncc/definitions/flashover"},{"c":"Definition","t":"Flight","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_448dd81f-b4c5-4c29-9aec-d57b83b33db5","x":"That part of a stair that has a continuous series of risers, including risers of winders, not interrupted by a landing or floor.","g":"/ncc/definitions/flight"},{"c":"Definition","t":"Flood hazard area","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_3220782b-f892-4b44-a260-95123b7a9ed0","x":"The site (whether or not mapped) encompassing land lower than the flood hazard level which has been determined by the appropriate authority.","g":"/ncc/definitions/flood-hazard-area"},{"c":"Definition","t":"Flood hazard level (FHL)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_eda7a634-864d-427e-97fe-27825f81ea48","x":"The flood level used to determine the height of floors in a building and represents the defined flood level plus the freeboard (see Figure 3).\nFHL","g":"/ncc/definitions/flood-hazard-level-fhl"},{"c":"Definition","t":"Floor area","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_7da927fe-453e-424f-b6ec-280f4e464397","x":"For the purposes of—\nVolume One—\nin relation to a building — the total area of all storeys; and\nin relation to a storey — the area of all floors of that storey measured over the enclosing walls, and includes—\nthe area of a mezzanine within the storey, measured within the finished surfaces of any external walls; and\nthe area occupied by any internal wall or partitions, any cupboard, or other built-in furniture, fixture or fitting; and\nif there is no enclosing wall, an area which has a use that contributes to the fire load or impacts on the safety, health or amenity of the occupants in relation to the provisions of the BCA; and\nin relation to a room — the area of the room measured within the internal finished surfaces of the walls, and includes the area occupied by any cupboard or other built-in furniture, fixture or fitting; and\nin relation to a fire compartment — the total area of all floors within the fire compartment measured within the finished internal surfaces of the bounding construction, and if there is no bounding construction, includes an area which has a use which contributes to the fire load; and\nin relation to an atrium — the total area of all floors within the atrium measured within the finished surfaces of the bounding construction and if no bounding construction, within the external walls.\nVolume Two and the ABCB Housing Provisions, in relation to a room, the area of the room measured within the finished surfaces of the walls, and includes the area occupied by any cupboard or other built-in furniture, fixture or fitting (see Figure 4).\nFigure 4 Identification of floor area of a room","g":"/ncc/definitions/floor-area"},{"c":"Definition","t":"Floor waste","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_3aa47b15-8473-4ba3-ae33-cf9b2d99ad0b","x":"A grated inlet within a graded floor intended to drain the floor surface.","g":"/ncc/definitions/floor-waste"},{"c":"Definition","t":"Flying scenery (NSW)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_1b7fe2fc-57ab-4302-b1c7-797a2a8e9756","x":"Scenery of a kind that is lifted above the stage floor by means of lines run from a grid.","g":"/ncc/definitions/flying-scenery-nsw"},{"c":"Definition","t":"Foundation","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_8bb7272b-1ab2-45ba-9642-40b192e2393a","x":"The ground which supports the building (see Figure 5).\nFigure 5 Identification of foundation","g":"/ncc/definitions/foundation"},{"c":"Definition","t":"Fractional effective dose (FED)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_b2c9af3c-abec-4ada-ae1f-9e27fae89acf","x":"The fraction of the dose (of thermal effects) that would render a person of average susceptibility incapable of escape.\nFED","g":"/ncc/definitions/fractional-effective-dose-fed"},{"c":"Definition","t":"Freeboard","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_c81fc55b-6eda-449e-82ad-fd9ec9e37cd9","x":"The height above the defined flood level as determined by the appropriate authority, used to compensate for effects such as wave action and localised hydraulic behaviour.","g":"/ncc/definitions/freeboard"},{"c":"Definition","t":"Fully developed fire","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_2926e928-d7ac-4f61-ae10-bac41d57366f","x":"The state of total involvement of the majority of available combustible materials in a fire.","g":"/ncc/definitions/fully-developed-fire"},{"c":"Definition","t":"Garage top dwelling (NSW)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_702eed44-bee6-4933-9140-23047aa61825","x":"A Class 1a dwelling located above a Class 10a private garage which is not associated with that Class 1a dwelling and includes any internal entry stair serving the garage top dwelling.","g":"/ncc/definitions/garage-top-dwelling-nsw"},{"c":"Definition","t":"Glazing","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_50325745-1d02-4c68-85ac-bd7c1a787b1e","x":"For the purposes of—\nSection J of Volume One, except for a sole-occupancy unit of a Class 2 building or a Class 4 part of a building—\na transparent or translucent element and its supporting frame located in the envelope; and\nincludes a window other than a roof light; or\nSection J of NCC Volume One, for a sole-occupancy unit of a Class 2 building or a Class 4 part of a building—\na translucent element and its supporting frame located in the external fabric of the building; and\nincludes a window other than a roof light; or\nPart H6 of NCC Volume Two and Section 13 of the ABCB Housing Provisions—\na transparent or translucent element and its supporting frame located in the external fabric of the building; and\nincludes a window other than a roof light.","g":"/ncc/definitions/glazing"},{"c":"Definition","t":"Going","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_b95f17ae-b7d5-4cd1-af19-54d4096f263c","x":"The horizontal dimension from the front to the back of a tread less any overhang from the next tread or landing above (see Figure 11.2.2f in the ABCB Housing Provisions).","g":"/ncc/definitions/going"},{"c":"Definition","t":"Green Star","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_59b54ff5-6934-4bc5-aca4-fedfd859b96b","x":"The building sustainability rating scheme managed by the Green Building Council of Australia.","g":"/ncc/definitions/green-star"},{"c":"Definition","t":"Grid (NSW)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_8d3a2b17-1ee1-4bf9-a6af-063719f65c35","x":"A framework from which lines are run for the purpose of lifting flying scenery above the stage floor.","g":"/ncc/definitions/grid-nsw"},{"c":"Definition","t":"Group number","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_98b60468-48ff-40b6-9c9a-57b1ad3cd803","x":"The number of one of 4 groups of materials used in the regulation of fire hazard properties and applied to materials used as a finish, surface, lining, or attachment to a wall or ceiling.","g":"/ncc/definitions/group-number"},{"c":"Definition","t":"Habitable room","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_b8eec66f-9c05-425d-8474-e6a2dfc2c0f4","x":"A room used for normal domestic activities, and—\nincludes a bedroom, living room, lounge room, music room, television room, kitchen, dining room, sewing room, study, playroom, family room, home theatre and sunroom; but\nexcludes a bathroom, laundry, water closet, pantry, walk-in wardrobe, corridor, hallway, lobby, photographic darkroom, clothes-drying room, and other spaces of a specialised nature occupied neither frequently nor for extended periods.","g":"/ncc/definitions/habitable-room"},{"c":"Definition","t":"Hazard Rating","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_e221b82c-bc4b-43d2-ab64-522dd5dd1885","x":"A level of potential toxicity that may cause contamination in a drinking water system, having a rating of Low Hazard, Medium Hazard or High Hazard, determined in accordance with NCC Volume Three.","g":"/ncc/definitions/hazard-rating"},{"c":"Definition","t":"Health-care building","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_1f5fbee8-584a-4244-9286-ebf9d8ebb04a","x":"A building whose occupants or patients undergoing medical treatment generally need physical assistance to evacuate the building during an emergency and includes—\na public or private hospital; or\na nursing home or similar facility for sick or disabled persons needing full-time care; or\na clinic, day surgery or procedure unit where the effects of the predominant treatment administered involve patients becoming non-ambulatory and requiring supervised medical care on the premises for some time after the treatment.","g":"/ncc/definitions/health-care-building"},{"c":"Definition","t":"Heated water","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_92b3a3dc-59e4-425f-909b-d8eb03e6460a","x":"Water that has been intentionally heated; normally referred to as hot water or warm water.","g":"/ncc/definitions/heated-water"},{"c":"Definition","t":"Heating degree hours","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_3b6db07a-1163-4370-97e7-a7696dbb44b2","x":"For any one hour when the mean outdoor air temperature is less than 15°C, the degrees Celsius temperature difference between the mean outdoor air temperature and 15°C.","g":"/ncc/definitions/heating-degree-hours"},{"c":"Definition","t":"Heating load","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_4dc3aa38-1ac4-4ad8-92f1-c4c52e332554","x":"The calculated amount of energy delivered to the heated spaces of the building annually by artificial means to maintain the desired temperatures in those spaces.","g":"/ncc/definitions/heating-load"},{"c":"Definition","t":"Heat release","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_05eb1484-247e-4148-aa82-6163481b96da","x":"The thermal energy produced by combustion (measured in kJ).","g":"/ncc/definitions/heat-release"},{"c":"Definition","t":"Heat release rate (HRR)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_e89ebf64-19d7-484b-a0be-2f89624693e9","x":"The rate of thermal energy production generated by combustion, measured in kW (preferred) or MW.\nHRR","g":"/ncc/definitions/heat-release-rate-hrr"},{"c":"Definition","t":"High Hazard","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_ef1e79a4-57f6-4a86-8d5f-ba231ba4e684","x":"Any condition, device or practice which, in connection with a water supply, has the potential to cause death.","g":"/ncc/definitions/high-hazard"},{"c":"Definition","t":"High wind area","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_7446e0cb-0c9c-48d3-bff3-129084473ddb","x":"A region that is subject to design wind speed more than N3 or C1 (see Table 4).","g":"/ncc/definitions/high-wind-area"},{"c":"Definition","t":"Hob","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_6daa7d7f-9147-4c10-98bc-c3cee9774bdb","x":"The upstand at the perimeter of a shower area.","g":"/ncc/definitions/hob"},{"c":"Definition","t":"Horizontal exit","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_45cfdc7e-cb0d-4318-95cc-462e079e9b9c","x":"A required doorway between 2 parts of a building separated from each other by a fire wall.","g":"/ncc/definitions/horizontal-exit"},{"c":"Definition","t":"Hotel offering shared accommodation (VIC)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_6b1dea3f-dce4-4dad-863e-8a82b41ce1b2","x":"A hotel which has any sole-occupancy units that can be shared by unrelated persons.","g":"/ncc/definitions/hotel-offering-shared-accommodation-vic"},{"c":"Definition","t":"Hours of operation","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_22178a20-4ed7-4cee-8507-b36346202638","x":"The number of hours when the occupancy of the building is at least 20% of the peak occupancy.","g":"/ncc/definitions/hours-of-operation"},{"c":"Definition","t":"House energy rating software","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_c3e52045-6061-460e-93b7-bf5293430c15","x":"For the purposes of—\nVolume One, applied to J3D3 or J3D15 — software accredited under the Nationwide House Energy Rating Scheme (NatHERS); or—\nVolume Two—\napplied to H6V2 — software accredited or previously accredited under the Nationwide House Energy Rating Scheme (NatHERS) and the additional functionality provided in non-regulatory mode; and\napplied to Specification 42 — software accredited under the Nationwide House Energy Rating Scheme (NatHERS).","g":"/ncc/definitions/house-energy-rating-software"},{"c":"Definition","t":"Illuminance","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_f3fc0ea9-6656-4e98-b020-380b3ab68684","x":"The luminous flux falling onto a unit area of surface.","g":"/ncc/definitions/illuminance"},{"c":"Definition","t":"Illumination power density","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_cb831616-4067-469f-ae62-121c80dd2c31","x":"The total of the power that will be consumed by the lights in a space, including any lamps, ballasts, current regulators and control devices other than those that are plugged into socket outlets for intermittent use such as floor standing lamps, desk lamps or work station lamps, divided by the area of the space, and expressed in W/m2.","g":"/ncc/definitions/illumination-power-density"},{"c":"Definition","t":"Inclined lift","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_b2e6e552-f765-4e60-83b5-9be6bd593c84","x":"A power-operated device for raising or lowering people within a carriage that has one or more rigid guides on an inclined plane.","g":"/ncc/definitions/inclined-lift"},{"c":"Definition","t":"Individual protection","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_9f04cdcd-91b5-41a3-81b7-1243261eb779","x":"The installation of a backflow prevention device at the point where a water service connects to a single fixture or appliance.","g":"/ncc/definitions/individual-protection"},{"c":"Definition","t":"Information and education facility (NSW)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_0e581681-fa8e-45e7-a58d-1044722b2c1d","x":"Is as defined in the Standard Instrument—Principal Local Environment Plan.","g":"/ncc/definitions/information-and-education-facility-nsw"},{"c":"Definition","t":"Insulation","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_b82f78d0-4656-4aa6-a223-7e52301ea308","x":"In relation to an FRL, the ability to maintain a temperature on the surface not exposed to the furnace below the limits specified in AS 1530.4.","g":"/ncc/definitions/insulation"},{"c":"Definition","t":"Integrity","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_4f47ab4d-35df-47b0-ba07-b167e4a56bd0","x":"In relation to an FRL, the ability to resist the passage of flames and hot gases specified in AS 1530.4.","g":"/ncc/definitions/integrity"},{"c":"Definition","t":"Internal wall","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_dcefb5ef-fe53-4a58-8f5d-62e87b269706","x":"For the purposes of—\nVolume One, excludes a common wall or a party wall; or\nVolume Two, excludes a separating wall, common wall or party wall.","g":"/ncc/definitions/internal-wall"},{"c":"Definition","t":"Interstitial condensation","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_3bbcdca4-9ce2-4f66-a7c5-6efcc3b0417e","x":"The condensation of moisture on surfaces between material layers inside the building component.","g":"/ncc/definitions/interstitial-condensation"},{"c":"Definition","t":"Irrigation system","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_960689be-8fdf-4b77-adf7-4209c739baa0","x":"An irrigation system of the following types:\nType A— all permanently open outlets and piping more than 150 mm above finished surface level, not subject to ponding or backpressure and not involving injection systems.\nType B— irrigation systems in domestic or residential buildings with piping or outlets installed less than 150 mm above finished surface level and not involving injection systems.\nType C— irrigation systems in other than domestic or residential buildings with piping outlets less than 150 mm above finished surface level and not involving injection systems.\nType D— irrigation systems where fertilizers, herbicides, nematicides or the like are injected or siphoned into the system.","g":"/ncc/definitions/irrigation-system"},{"c":"Definition","t":"JASANZ","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_f0e3e224-51ef-4aeb-a774-abf803e00120","x":"The Joint Accreditation System of Australia and New Zealand.","g":"/ncc/definitions/jasanz"},{"c":"Definition","t":"Kerb ramp","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_ec78b11f-071d-4862-b700-dc50cf921b45","x":"A ramp incorporated in a kerb.","g":"/ncc/definitions/kerb-ramp"},{"c":"Definition","t":"Lamp power density","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_4f274575-a7db-4987-ac0e-5f546df36a48","x":"The total of the maximum power rating of the lamps in a space, other than those that are plugged into socket outlets for intermittent use such as floor standing lamps, desk lamps or work station lamps, divided by the area of the space, and expressed in W/m2.","g":"/ncc/definitions/lamp-power-density"},{"c":"Definition","t":"Landing","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_68f79d99-aa42-455d-86ad-cae355bfc435","x":"An area at the top or bottom of a flight or between two flights.","g":"/ncc/definitions/landing"},{"c":"Definition","t":"Latent heat gain","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_ae7e378c-f02b-475a-9e17-a7c07e7340ac","x":"The heat gained by the vapourising of liquid without change of temperature.","g":"/ncc/definitions/latent-heat-gain"},{"c":"Definition","t":"Lateral support","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_97a16a67-ef19-48da-84e4-511832dcd4bb","x":"A support (including a footing, buttress, cross wall, beam, floor or braced roof structure) that effectively restrains a wall or pier at right angles to the face of the wall or pier.","g":"/ncc/definitions/lateral-support"},{"c":"Definition","t":"Lead free","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_6f7d0447-9596-4bd4-9727-4cc26785de8c","x":"Where a plumbing product or material in contact with drinking water has a weighted average lead content of not more than 0.25%.","g":"/ncc/definitions/lead-free"},{"c":"Definition","t":"Licensed premises (NSW)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_ea5bac87-be4b-42a4-92c6-c6c09408af6d","x":"Is as defined in the Liquor Act 2007.","g":"/ncc/definitions/licensed-premises-nsw"},{"c":"Definition","t":"Licensed premises (WA)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_23569ad0-6894-4033-b7e0-1c6ad7e7ab7f","x":"Includes—\npremises in respect of which a cabaret licence as defined by the Liquor Control Act 1988 has been granted under that Act; or\npremises in respect of which a tavern licence, a hotel restricted licence or any other kind of hotel licence as defined by the Liquor Control Act 1988 has been granted under that Act; or\na cabaret, hotel or tavern—\nin respect of which a special facility licence as defined by the Liquor Control Act 1988 has been granted under that Act; and\nin respect of which paragraph (a) or (b) does not apply.","g":"/ncc/definitions/licensed-premises-wa"},{"c":"Definition","t":"Lightweight construction","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_2cf43983-ddc7-4b7f-b16e-2d3ed619886e","x":"Construction which incorporates or comprises—\nsheet or board material, plaster, render, sprayed application, or other material similarly susceptible to damage by impact, pressure or abrasion; or\nconcrete and concrete products containing pumice, perlite, vermiculite, or other soft material similarly susceptible to damage by impact, pressure or abrasion; or\nmasonry having a width of less than 70 mm.","g":"/ncc/definitions/lightweight-construction"},{"c":"Definition","t":"Loadbearing","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_fe6e68c5-3fcb-4038-844a-2fcb7099f7da","x":"Intended to resist vertical forces additional to those due to its own weight.","g":"/ncc/definitions/loadbearing"},{"c":"Definition","t":"Loadbearing wall","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_37f88f55-d0f3-4ee5-b305-3c0a6e5d80a2","x":"For the purposes of H1D4 and H2D3 of NCC Volume Two and Section 4 of the ABCB Housing Provisions, means any wall imposing on the footing a load greater than 10 kN/m.","g":"/ncc/definitions/loadbearing-wall"},{"c":"Definition","t":"Loss","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_ba5bd5ee-ef5f-41be-b153-43835028cd86","x":"Physical damage, financial loss or loss of amenity.","g":"/ncc/definitions/loss"},{"c":"Definition","t":"Low Hazard","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_a0833472-40bb-4aef-be33-83a99f580c7c","x":"Any condition, device or practice which, in connection with a water supply, would constitute a nuisance by colour, odour or taste but does not have the potential to injure or endanger health.","g":"/ncc/definitions/low-hazard"},{"c":"Definition","t":"Low rainfall intensity area","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_6ff52a3c-f661-4540-bc88-52b7597794a9","x":"An area with a 5 minute rainfall intensity for an annual exceedance probability of 5% of not more than 125 mm/hour.","g":"/ncc/definitions/low-rainfall-intensity-area"},{"c":"Definition","t":"Low-rise, low-speed constant pressure lift","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_c982b738-482e-4782-99c0-bc404eeb58dc","x":"A power-operated low-rise, low-speed device for raising or lowering people with limited mobility on a carriage that is controlled by the application of constant pressure to a control.","g":"/ncc/definitions/low-rise-low-speed-constant-pressure-lift"},{"c":"Definition","t":"Low-rise platform lift","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_86024f54-4130-4c03-9369-e27f9992c615","x":"A power-operated device for raising or lowering people with limited mobility on a platform, that is controlled automatically or by the application of constant pressure to a control.","g":"/ncc/definitions/low-rise-platform-lift"},{"c":"Definition","t":"Low voltage","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_9e123bf7-7fde-4888-864b-3274980990f2","x":"A voltage exceeding extra-low voltage, but not exceeding 1000 V AC or 1500 V DC.","g":"/ncc/definitions/low-voltage"},{"c":"Definition","t":"Luminance contrast","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_a01e03e9-1ea5-4a56-980c-85d53fd9cb5b","x":"The light reflected from one surface or component, compared to the light reflected from another surface or component.","g":"/ncc/definitions/luminance-contrast"},{"c":"Definition","t":"Main water heater","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_22f92ffc-bae9-49e2-9f26-4d7983fbdc72","x":"The domestic hot water unit in a dwelling that is connected to at least one shower and the largest number of hot water outlets.","g":"/ncc/definitions/main-water-heater"},{"c":"Definition","t":"Main space conditioning","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_2ee5b27e-a2e8-4d00-8717-736a7ac0ab59","x":"Either—\nthe heating or cooling equipment that serves at least 70% of the conditioned space of a dwelling; or\nif no one heating or cooling equipment serves at least 70% of the conditioned space of the dwelling, the equipment that results in the highest net equivalent energy usage when calculated in accordance with J3D14(1)(a) of NCC Volume One or 13.6.2(1)(a) of the ABCB Housing Provisions.\nNotes\nIf a multi-split air-conditioning unit is installed, it is considered to be a single heating or cooling service.\nA series of separate heaters or coolers of the one type can be considered a single heater or cooler type with a performance level of that of the unit with the lowest efficiency.","g":"/ncc/definitions/main-space-conditioning"},{"c":"Definition","t":"Massive timber","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_6eb519ba-9aa9-4b7d-965e-a24db031ac37","x":"An element not less than 75 mm thick as measured in each direction formed from solid and laminated timber.","g":"/ncc/definitions/massive-timber"},{"c":"Definition","t":"Maximum retained water level","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_6eced409-c284-491d-95c7-2f9770e55186","x":"The point where surface water will start to overflow out of the shower area.","g":"/ncc/definitions/maximum-retained-water-level"},{"c":"Definition","t":"Medium Hazard","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_9edf8e98-0620-4b05-87e0-2ad738cb12b3","x":"Any condition, device or practice which, in connection with a water supply, has the potential to injure or endanger health.","g":"/ncc/definitions/medium-hazard"},{"c":"Definition","t":"Membrane","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_6e2c1aaa-5993-4850-908f-ac4007e94535","x":"A barrier impervious to moisture.","g":"/ncc/definitions/membrane"},{"c":"Definition","t":"Mezzanine","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_f68246d9-7a77-41fc-8050-516881323e47","x":"An intermediate floor within a room, that is not separated from that room by walls.","g":"/ncc/definitions/mezzanine"},{"c":"Definition","t":"Minimum Energy Performance Standards (MEPS)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_6d2d2ec4-793d-4384-98a5-f39ff765e8c8","x":"The Minimum Energy Performance Standards for equipment and appliances established through the Greenhouse and Energy Minimum Standards Act 2012.\nMEPS","g":"/ncc/definitions/minimum-energy-performance-standards-meps"},{"c":"Definition","t":"Minimum lateral clearance (NSW)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_eca7e619-9dda-452b-a146-69e5c89808ba","x":"A permanently unobstructed space having a height above floor level of not less than 2000 mm and a width of not less than the specified measurement.","g":"/ncc/definitions/minimum-lateral-clearance-nsw"},{"c":"Definition","t":"Mixed construction","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_1ecef255-4cf9-4fa7-b8ef-b22cf6c19952","x":"A building consisting of more than one form of construction, particularly in double-storey buildings.","g":"/ncc/definitions/mixed-construction"},{"c":"Definition","t":"Mould","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_df4dfb7a-730b-486e-8436-c1179ca02d4a","x":"A fungal growth that can be produced from conditions such as dampness, darkness, or poor ventilation.","g":"/ncc/definitions/mould"},{"c":"Definition","t":"NABERS Energy","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_ec872d9e-d88d-4372-9d60-43327a3cb139","x":"The National Australian Built Environment Rating Systems for energy efficiency, which is managed by the New South Wales Government.","g":"/ncc/definitions/nabers-energy"},{"c":"Definition","t":"Network Utility Operator","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_12d6153c-4986-4856-80c0-e21bb57af12f","x":"A person who—\nundertakes the piped distribution of drinking water or non-drinking water for supply; or\nis the operator of a sewerage system or a stormwater drainage system.","g":"/ncc/definitions/network-utility-operator"},{"c":"Definition","t":"Non-combustible","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_be8a1d10-4119-4eb0-a014-07a806b104ff","x":"Applied to—\na material — means not deemed combustible as determined by an Accredited Testing Laboratory in accordance with AS 1530.1 — Combustibility Tests for Materials; or\nconstruction or part of a building — means constructed wholly of materials that are not deemed combustible.\nNotes\nUntil the adoption of the next edition of the NCC, determination need not be undertaken by an Accredited Testing Laboratory.","g":"/ncc/definitions/non-combustible"},{"c":"Definition","t":"Non-drinking water","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_cfc4fec0-3cb7-41d6-b176-4a92d4cdb221","x":"Water which is not intended primarily for human consumption.","g":"/ncc/definitions/non-drinking-water"},{"c":"Definition","t":"Occupant traits","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_cb1f5882-6f34-4d7a-a605-a8a954b44bcb","x":"For the purposes of—\nVolume One, the features, needs and profile of the occupants in a habitable room or space; or\nVolume Two, the features, needs and profile of the occupants in a room or space.","g":"/ncc/definitions/occupant-traits"},{"c":"Definition","t":"Occupiable outdoor area","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_b74613d6-3cf2-489a-af62-321caa6c43d5","x":"A space on a roof, balcony or similar part of a building—\nthat is open to the sky; and\nto which access is provided, other than access only for maintenance; and\nthat is not open space or directly connected with open space.","g":"/ncc/definitions/occupiable-outdoor-area"},{"c":"Definition","t":"On-site wastewater management system","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_2396187d-8435-4f01-9dfd-613970a74823","x":"A system that receives and/or treats wastewater generated and discharges the resulting effluent to an approved disposal system or re-use system.","g":"/ncc/definitions/on-site-wastewater-management-system"},{"c":"Definition","t":"Open-deck carpark","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_98f99be0-5c03-48a8-8087-27bc99acc90d","x":"A carpark in which all parts of the parking storeys are cross-ventilated by permanent unobstructed openings in not fewer than 2 opposite or approximately opposite sides, and—\neach side that provides ventilation is not less than 1/6 of the area of any other side; and\nthe openings are not less than ½ of the wall area of the side concerned.","g":"/ncc/definitions/open-deck-carpark"},{"c":"Definition","t":"Open space","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_b4a20ca6-0197-4381-9e50-85c757fa574f","x":"A space on the allotment, or a roof or similar part of a building adequately protected from fire, open to the sky and connected directly with a public road.","g":"/ncc/definitions/open-space"},{"c":"Definition","t":"Open spectator stand","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_0403e22a-286f-4b36-b369-af068221632b","x":"A tiered stand substantially open at the front.","g":"/ncc/definitions/open-spectator-stand"},{"c":"Definition","t":"Other property","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_ffbca87e-eb18-4463-a6fb-e59b79881fa3","x":"All or any of the following—\nany building on the same or an adjoining allotment; and\nany adjoining allotment; and\na road.","g":"/ncc/definitions/other-property"},{"c":"Definition","t":"Outdoor air","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_eb74131f-b9dc-42bf-89c2-f68b788f9636","x":"Air outside the building.","g":"/ncc/definitions/outdoor-air"},{"c":"Definition","t":"Outdoor air economy cycle","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_0c10243a-8070-467d-9fd7-c356f555ba9b","x":"A mode of operation of an air-conditioning system that, when the outdoor air thermodynamic properties are favourable, increases the quantity of outdoor air used to condition the space.","g":"/ncc/definitions/outdoor-air-economy-cycle"},{"c":"Definition","t":"Outfall","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_828371c4-72b7-4dcc-bdb6-8bcf8232fca3","x":"That part of the disposal system receiving surface water from the drainage system and may include a natural water course, kerb and channel, or soakage system.","g":"/ncc/definitions/outfall"},{"c":"Definition","t":"Overflow device","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_9afe2a26-14eb-4b0c-92bc-4207768c9d09","x":"A device that provides relief to a water service, sanitary plumbing and drainage system, rainwater service or stormwater system to avoid the likelihood of uncontrolled discharge.","g":"/ncc/definitions/overflow-device"},{"c":"Definition","t":"Panel wall","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_75292f0a-aa7a-48b7-bcc2-0476e1b8c7bf","x":"A non-load bearing external wall, in frame or similar construction, that is wholly supported at each storey.","g":"/ncc/definitions/panel-wall"},{"c":"Definition","t":"Partially buried rainwater tank","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_165bf6c9-9375-4329-a497-d3d78a1d4b10","x":"A rainwater tank that is not completely covered by earth but is partially set into the ground.","g":"/ncc/definitions/partially-buried-rainwater-tank"},{"c":"Definition","t":"Patient care area","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_63b56568-e9c9-425f-8456-a332503c9520","x":"A part of a health-care building normally used for the treatment, care, accommodation, recreation, dining and holding of patients including a ward area and treatment area.","g":"/ncc/definitions/patient-care-area"},{"c":"Definition","t":"Performance-based design brief (PBDB)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_c591a3ca-5ded-4bee-bca5-edb5b5bf55d3","x":"The report that defines the scope of work for the performance-based analysis, the technical basis for analysis, and the criteria for acceptance of any relevant Performance Solution as agreed by stakeholders.\nPBDB","g":"/ncc/definitions/performance-based-design-brief-pbdb"},{"c":"Definition","t":"Performance Requirement","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_f7304862-3529-49d7-9f62-352bcbcb6294","x":"A requirement which states the level of performance which a Performance Solution or Deemed-to-Satisfy Solution must meet.","g":"/ncc/definitions/performance-requirement"},{"c":"Definition","t":"Performance Solution","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_e3f95f1d-e1cc-4ab3-961d-c99a213a1de3","x":"A method of complying with the Performance Requirements other than by a Deemed-to-Satisfy Solution.","g":"/ncc/definitions/performance-solution"},{"c":"Definition","t":"Perimeter of building","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_2cb50d43-2eff-4671-8f89-de99220183c9","x":"For the purposes of Section 8 of the Housing Provisions, means the external envelope of a building.","g":"/ncc/definitions/perimeter-of-building"},{"c":"Definition","t":"Permit Authority (TAS)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_dc543ae0-a4fa-45f8-8b6d-f1756e30cf95","x":"A permit authority as defined in the Building Act 2016.","g":"/ncc/definitions/permit-authority-tas"},{"c":"Definition","t":"Personal care services","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_12c4de44-adaf-4ca3-8f2d-cc1a29b53e65","x":"Any of the following:\nThe provision of nursing care.\nAssistance or supervision in—\nbathing, showering or personal hygiene; or\ntoileting or continence management; or\ndressing or undressing; or\nconsuming food.\nThe provision of direct physical assistance to a person with mobility problems.\nThe management of medication.\nThe provision of substantial rehabilitative or development assistance.","g":"/ncc/definitions/personal-care-services"},{"c":"Definition","t":"Piping","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_83695a00-3a6b-4a83-b26a-9faa46d4e1dc","x":"For the purposes of Section J in Volume One or Part H6 in Volume Two, and Section 13 of the Housing Provisions, means an assembly of pipes, with or without valves or other fittings, connected together for the conveyance of liquids and gases.","g":"/ncc/definitions/piping"},{"c":"Definition","t":"Planning for Bush Fire Protection (NSW)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_6d8e5c13-069a-40f6-a2de-0890cbfcd647","x":"Is as prescribed by the Environmental Planning and Assessment Regulation 2021.","g":"/ncc/definitions/planning-for-bush-fire-protection-nsw"},{"c":"Definition","t":"Pliable building membrane","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_5a207162-320e-44eb-b264-70d6d38aae74","x":"A water barrier as classified by AS 4200.1.","g":"/ncc/definitions/pliable-building-membrane"},{"c":"Definition","t":"Plumbing","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_a318c0f3-5635-4ac0-b103-59d798c9f23d","x":"Any water service plumbing or sanitary plumbing system.","g":"/ncc/definitions/plumbing"},{"c":"Definition","t":"Plumbing or Drainage Solution","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_6996aaa7-c9dd-4c1b-a74e-0bf12ce58f64","x":"A solution which complies with the Performance Requirement and is a—\nPerformance Solution; or\nDeemed-to-Satisfy Solution; or\ncombination of (a) and (b).","g":"/ncc/definitions/plumbing-or-drainage-solution"},{"c":"Definition","t":"Point of connection","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_7df493b5-1832-40a0-b9d0-d2fb3fec5d98","x":"Any of the following:\nFor a cold water service, means the point where the cold water service connects to—\nthe Network Utility Operator's water supply system; or\nthe point of isolation to an alternative water source where there is no Network Utility Operator's water supply available or is not utilised.\nFor a heated water service, means the point where the water heater connects to the cold water service downstream of the isolation valve.\nFor sanitary drainage, means the point where the on-site sanitary drainage system connects to—\nthe Network Utility Operator's sewerage system; or\nan on-site wastewater management system.\nFor sanitary plumbing, means the point where the sanitary plumbing system connects to the sanitary drainage system.\nFor a rainwater service, means the point where the rainwater service —\nconnects to the point of isolation for the rainwater storage; or\ndraws water from the rainwater storage.\nFor stormwater disposal, means the point where the on-site stormwater drainage system connects to—\nthe Network Utility Operator's stormwater system; or\nan approved on-site disposal system.\nFor a fire-fighting water service, means the point where the service connects to—\na cold water service, downstream of a backflow prevention device; or\nthe Network Utility Operator's water supply system; or\nthe point of isolation to an alternative water source.\nFor rainwater storage, means the point of rainwater entry to the rainwater storage.\nNotes\nA domestic fire sprinkler service conforming to FPAA101D is considered part of the cold water service.","g":"/ncc/definitions/point-of-connection"},{"c":"Definition","t":"Predicted Mean Vote (PMV)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_50155542-eddc-47be-acea-a15f2c017dea","x":"The Predicted Mean Vote of the thermal perception of building occupants determined in accordance with ANSI/ASHRAE Standard 55.\nPMV","g":"/ncc/definitions/predicted-mean-vote-pmv"},{"c":"Definition","t":"Preformed shower base","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_a207c296-a8b3-4ffe-81e0-a598ccc4b4d8","x":"A preformed, prefinished vessel installed as the finished floor of a shower compartment, and which is provided with a connection point to a sanitary drainage system.","g":"/ncc/definitions/preformed-shower-base"},{"c":"Definition","t":"Pressure vessel","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_3be0ceb4-ef72-40e5-8aaa-ae75f63e4bd4","x":"A vessel subject to internal or external pressure, including interconnected parts and components, valves, gauges and other fittings up to the first point of connection to connecting piping, and—\nincludes fire heaters and gas cylinders; but\nexcludes—\nany vessel that falls within the definition of a boiler; and\nstorage tanks and equipment tanks intended for storing liquids where the pressure at the top of the tank is not exceeding 1.4 kPa above or 0.06 kPa below atmospheric pressure; and\ndomestic-type hot water supply heaters and tanks; and\npressure vessels installed for the purposes of fire suppression or which serve a fire suppression system.","g":"/ncc/definitions/pressure-vessel"},{"c":"Definition","t":"Primary building element","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_5b1a07fa-ec9d-48a4-ad73-77cd5f362d25","x":"For the purposes of—\nVolume One, a member of a building designed specifically to take part of the loads specified in B1D3 and includes roof, ceiling, floor, stairway or ramp and wall framing members including bracing members designed for the specific purpose of acting as a brace to those members; or\nPart 3.4 of the ABCB Housing Provisions, a member of a building designed specifically to take part of the building loads and includes roof, ceiling, floor, stairway or ramp and wall framing members including bracing members designed for the specific purpose of acting as a brace to those members.","g":"/ncc/definitions/primary-building-element"},{"c":"Definition","t":"Primary insulation layer","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_e0128ee3-46f3-45d2-9b1b-e069b935fd58","x":"The most interior insulation layer of a wall or roof construction.","g":"/ncc/definitions/primary-insulation-layer"},{"c":"Definition","t":"Private bushfire shelter","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_a66b2361-e930-4dce-92d3-1a46a071e27f","x":"A structure associated with, but not attached to, or part of a Class 1a dwelling that may, as a last resort, provide shelter for occupants from immediate life threatening effects of a bushfire.","g":"/ncc/definitions/private-bushfire-shelter"},{"c":"Definition","t":"Private garage","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_230a3a0f-1539-4b9d-9a2d-8edf732e59dd","x":"For the purposes of—\nVolume One—\nany garage associated with a Class 1 building; or\nany single storey of a building of another Class containing not more than 3 vehicle spaces, if there is only one such storey in the building; or\nany separate single storey garage associated with another building where such garage contains not more than 3 vehicle spaces; or\nVolume Two—\nany garage associated with a Class 1 building; or\nany separate single storey garage associated with another building where such garage contains not more than 3 vehicle spaces.","g":"/ncc/definitions/private-garage"},{"c":"Definition","t":"Product","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_24195589-302c-49fb-bf91-bfa3db6cb767","x":"Plumbing and drainage items within the scope of Volume Three including but not limited to—\nmaterials, fixtures and components used in a plumbing or drainage installation; and\nappliances and equipment connected to a plumbing or drainage system.","g":"/ncc/definitions/product"},{"c":"Definition","t":"Product Technical Statement","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_36953c90-50bb-4118-bd48-56c43d5a510c","x":"A form of documentary evidence stating that the properties and performance of a building material, product or form of construction fulfil specific requirements of the NCC, and describes—\nthe application and intended use of the building material, product or form of construction; and\nhow the use of the building material, product or form of construction complies with the requirements of the NCC Volume One and Volume Two; and\nany limitations and conditions of the use of the building material, product or form of construction relevant to (b).","g":"/ncc/definitions/product-technical-statement"},{"c":"Definition","t":"Professional engineer","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_f2188149-a0d6-45f9-88bf-945014ab6d7e","x":"A person who is—\nif legislation is applicable — a registered professional engineer in the relevant discipline who has appropriate experience and competence in the relevant field; or\nif legislation is not applicable—\nregistered in the relevant discipline on the National Engineering Register (NER) of the Institution of Engineers Australia (which trades as ‘Engineers Australia’); or\neligible to become registered on the Institution of Engineers Australia’s NER and has appropriate experience and competence in the relevant field.","g":"/ncc/definitions/professional-engineer"},{"c":"Definition","t":"Projection suite (NSW)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_9c468f5f-cc5c-46d4-bd24-18206a0a6881","x":"Such part of an entertainment venue as is designed to accommodate apparatus used for projecting films.","g":"/ncc/definitions/projection-suite-nsw"},{"c":"Definition","t":"Public (TAS)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_98c47bc1-2d11-4c2d-8f0b-0534808fa254","x":"Includes any person working in an enclosed public place.","g":"/ncc/definitions/public-tas"},{"c":"Definition","t":"WA Public building (WA)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_da789fac-c334-4952-a23b-ac344815d25a","x":"A Class 6 licensed premises or Class 9b building where persons may assemble for—\ncivic, theatrical, social, political or religious purposes; or\neducational purposes; or\nentertainment, recreational or sporting purposes; or\nbusiness purposes.","g":"/ncc/definitions/wa-public-building-wa"},{"c":"Definition","t":"Public corridor","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_eea79623-bc7d-4ef1-b787-8452b6383ffc","x":"An enclosed corridor, hallway or the like which—\nserves as a means of egress from 2 or more sole-occupancy units to a required exit from the storey concerned; or\nis required to be provided as a means of egress from any part of a storey to a required exit.","g":"/ncc/definitions/public-corridor"},{"c":"Definition","t":"Rainwater","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_13115a1a-3513-4393-a7b2-4d6cfeb13be0","x":"Naturally occurring water generated by a rain or storm event.","g":"/ncc/definitions/rainwater"},{"c":"Definition","t":"Rainwater service","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_bd764954-3054-4109-81f2-164feefc5058","x":"A water service which distributes water from the isolation valve of the rainwater storage to the rainwater points of discharge for purposes such as for clothes washing, urinal and water closet flushing and external hose cocks.","g":"/ncc/definitions/rainwater-service"},{"c":"Definition","t":"Rainwater storage","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_a8d909a0-d649-477d-a969-848c9187c05d","x":"Any storage of rainwater collected from a roof catchment area which is used to supply water for the primary purposes of drinking, personal hygiene or other uses.","g":"/ncc/definitions/rainwater-storage"},{"c":"Definition","t":"Rainwater tank (SA)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_cf5f5352-d0c0-41ff-a6ed-c8ca972b4c0a","x":"A vessel for the storage of surface water collected from the roof catchment area of the building.","g":"/ncc/definitions/rainwater-tank-sa"},{"c":"Definition","t":"Rapid roller door","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_570b2a27-30d6-43ca-b6ee-fe4a5b27be48","x":"A door that opens and closes at a speed of not less than 0.5 m/s.","g":"/ncc/definitions/rapid-roller-door"},{"c":"Definition","t":"Recognised expert","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_1250ef36-8ec2-4f72-b682-415e3a8102cd","x":"A person with qualifications and experience in the area of plumbing or drainage in question recognised by the authority having jurisdiction.","g":"/ncc/definitions/recognised-expert"},{"c":"Definition","t":"Redirected","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_19dd48b1-70e1-4c21-8427-729299276926","x":"For the purposes of Section F in NCC Volume One, the changing of direction of collected water to a drainage system.","g":"/ncc/definitions/redirected"},{"c":"Definition","t":"Reference building","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_5dfc40fe-dad0-46ab-9923-f7643beb2160","x":"For the purposes of—\nVolume One, a hypothetical building that is used to calculate the maximum allowable—\nannual greenhouse gas emissions for the common area of a Class 2 building or a Class 3 to 9 building; or\nheating load, cooling load and energy value for a sole-occupancy unit of a Class 2 building or a Class 4 part of a building; or\nVolume Two, a hypothetical building that is used to determine the maximum allowable heating load and cooling load for the proposed building.","g":"/ncc/definitions/reference-building"},{"c":"Definition","t":"Reflective insulation","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_710062da-7211-491f-ad4c-b3f12b9b96bb","x":"A building membrane with a reflective surface such as a reflective foil laminate, reflective barrier, foil batt or the like capable of reducing radiant heat flow.","g":"/ncc/definitions/reflective-insulation"},{"c":"Definition","t":"Regulated energy","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_044c235a-5f51-4bc7-9eb9-7cfba1a0f023","x":"The energy consumed by a building's services minus the amount of renewable energy generated and used on site.","g":"/ncc/definitions/regulated-energy"},{"c":"Definition","t":"Reinforced masonry","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_3a35df8b-567f-47a3-baa1-70a0192bd5eb","x":"Masonry reinforced with steel reinforcement that is placed in a bed joint or grouted into a core to strengthen the masonry.","g":"/ncc/definitions/reinforced-masonry"},{"c":"Definition","t":"Reliability","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_02cf4ab9-bcd0-4114-b257-312bdd83d376","x":"The probability that a system performs to a level consistent with the system specification.","g":"/ncc/definitions/reliability"},{"c":"Definition","t":"Renewable energy","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_50889924-ff55-40a3-96eb-605b00ba5034","x":"Energy that is derived from sources that are regenerated, replenished, or for all practical purposes cannot be depleted and the energy sources include, but are not limited to, solar, wind, hydroelectric, wave action and geothermal.","g":"/ncc/definitions/renewable-energy"},{"c":"Definition","t":"Required","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_af6fde9f-147d-4782-8b85-42044e80fd42","x":"Required to satisfy a Performance Requirement or a Deemed-to-Satisfy Provision of the NCC as appropriate.","g":"/ncc/definitions/required"},{"c":"Definition","t":"Required safe egress time (RSET)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_181eb122-8304-45e5-986a-780b3d92a58b","x":"The time required for safe evacuation of occupants to a place of safety prior to the onset of untenable conditions.\nRSET","g":"/ncc/definitions/required-safe-egress-time-rset"},{"c":"Definition","t":"Residential aged care building","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_d421a23a-314a-49a0-8732-395e884a7a39","x":"A Class 3 or 9a building whose residents, due to their incapacity associated with the ageing process, are provided with physical assistance in conducting their daily activities and to evacuate the building during an emergency.","g":"/ncc/definitions/residential-aged-care-building"},{"c":"Definition","t":"Residential care building","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_b286ccd1-342e-49e1-95e9-4b6a0a6c0447","x":"A Class 3, 9a or 9c building which is a place of residence where 10% or more of persons who reside there need physical assistance in conducting their daily activities and to evacuate the building during an emergency (including any aged care building or residential aged care building) but does not include a hospital.","g":"/ncc/definitions/residential-care-building"},{"c":"Definition","t":"Residential care building (Vic) (VIC)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_5ab30347-b491-4403-b95c-dba5ab5d9aec","x":"A building which is a place of residence where 10% or more of persons who reside there need physical assistance in conducting their daily activities and to evacuate the building during an emergency (including any residential care service, State funded residential care service or supported residential service as defined in the Supported Residential Services (Private Proprietors) Act 2010 and an aged care building) but does not include—\na hospital; or\na dwelling in which 2 or more members of the same family and not more than 2 other persons would ordinarily be resident; or\na place of residence where only one resident needs physical assistance in conducting their daily activities and to evacuate the building during an emergency.","g":"/ncc/definitions/residential-care-building-vic-vic"},{"c":"Definition","t":"Resident use area","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_071db02d-667d-447e-9f1e-8de8c46b9e0e","x":"Part of a Class 9c building normally used by residents, and—\nincludes sole-occupancy units, lounges, dining areas, activity rooms and the like; but\nexcludes offices, storage areas, commercial kitchens, commercial laundries and other spaces not for the use of residents.","g":"/ncc/definitions/resident-use-area"},{"c":"Definition","t":"Resistance to the incipient spread of fire","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_617607ac-6215-49ef-8171-c069d7620b95","x":"In relation to a ceiling membrane, means the ability of the membrane to insulate the space between the ceiling and roof, or ceiling and floor above, so as to limit the temperature rise of materials in this space to a level which will not permit the rapid and general spread of fire throughout the space.","g":"/ncc/definitions/resistance-to-the-incipient-spread-of-fire"},{"c":"Definition","t":"Rise in storeys","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_7023b962-6482-412b-8416-ab1d9016072b","x":"The greatest number of storeys calculated in accordance with C2D3 of Volume One.","g":"/ncc/definitions/rise-in-storeys"},{"c":"Definition","t":"Riser","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_c719036a-be6e-4810-9535-cd37da0577cd","x":"The height between consecutive treads and between each landing and continuous tread.","g":"/ncc/definitions/riser"},{"c":"Definition","t":"Rising damp","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_b42748cd-d831-4046-9c03-f439a9a9fc99","x":"Water absorbed from the ground into a building element.","g":"/ncc/definitions/rising-damp"},{"c":"Definition","t":"Restricted children’s service (VIC)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_50885e6b-a68c-4be0-a0c4-ab94fbf8b27b","x":"A children’s service that is a limited hours service as defined in the Children’s Services Regulations 2020.","g":"/ncc/definitions/restricted-children-s-service-vic"},{"c":"Definition","t":"Rolled fill","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_45827564-6690-4f01-a40e-7e1b3c903a20","x":"Material placed in layers and compacted by repeated rolling by an excavator.","g":"/ncc/definitions/rolled-fill"},{"c":"Definition","t":"Roof catchment area (SA)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_3187551d-5acd-4272-8e27-5e636dc6fd25","x":"The area of the roof (expressed in square metres), measured on the horizontal (no allowance for slope or vertical surfaces) and includes the plan area of the gutters.","g":"/ncc/definitions/roof-catchment-area-sa"},{"c":"Definition","t":"Roof light","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_12b88f11-1c3d-4d91-bc65-02588a4dc524","x":"For the purposes of Section J and Part F6 in NCC Volume One, Part H6 in NCC Volume Two, and Part 10.5 and Section 13 of the ABCB Housing Provisions, a skylight, window or the like installed in a roof—\nto permit natural light to enter the room below; and\nat an angle between 0 and 70 degrees measured from the horizontal plane.","g":"/ncc/definitions/roof-light"},{"c":"Definition","t":"Row (NSW)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_0d278c41-777a-48f5-8130-efe976c8bf82","x":"A row of seating—\nbetween a wall or other barrier and an aisle; or\nbetween 2 aisles.","g":"/ncc/definitions/row-nsw"},{"c":"Definition","t":"R-Value","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_e5acb40f-3d3d-4a3d-8987-f09f7eaadf77","x":"The thermal resistance of a component calculated by dividing its thickness by its thermal conductivity, expressed in m2.K/W.","g":"/ncc/definitions/r-value"},{"c":"Definition","t":"Safe place","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_3733c0ba-89b2-472e-a914-4883883de939","x":"Either—\na place of safety within a building—\nwhich is not under threat from a fire; and\nfrom which people must be able to safely disperse after escaping the effects of an emergency to a road or open space; or\na road or open space.","g":"/ncc/definitions/safe-place"},{"c":"Definition","t":"Sanitary compartment","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_b30a308f-eb9f-4549-a6c1-19d5f32a5272","x":"A room or space containing a closet pan or urinal (see Figures 6a and 6b).\nFigure 6a Identification of a sanitary compartment (diagram a)\nFigure 6b Identification of a sanitary compartment (diagram b)","g":"/ncc/definitions/sanitary-compartment"},{"c":"Definition","t":"Sarking-type material","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_58664f4b-1409-41b5-987a-54aec55ac608","x":"A material such as a reflective insulation or other flexible membrane of a type normally used for a purpose such as waterproofing, vapour management or thermal reflectance.","g":"/ncc/definitions/sarking-type-material"},{"c":"Definition","t":"School","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_23515733-4511-421a-8c89-650d33e5f6e4","x":"Includes a primary or secondary school, college, university or similar educational establishment.","g":"/ncc/definitions/school"},{"c":"Definition","t":"School age care facility (TAS)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_60262e7b-23d7-4c30-9a45-63dc51e2b98b","x":"Is a facility providing care for children (primarily) 5 years or older in an outside of school hours setting, either approved or licenced under Education and Care Services National Law (Application) Act 2011 or the Child Care Act 2001.","g":"/ncc/definitions/school-age-care-facility-tas"},{"c":"Definition","t":"Screed","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_0aa8542c-9dff-4172-a8f8-a0d9d27a03ac","x":"A layer of material (usually cement based) which sets in situ between a structural base and the finished floor material.","g":"/ncc/definitions/screed"},{"c":"Definition","t":"Self-closing","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_7f0d37c8-f244-4a83-9a76-6ece85e1e430","x":"For the purposes of—\nVolume One, applied to a door, means equipped with a device which returns the door to the fully closed position immediately after each opening; or\nVolume Two, applied to a door or window, means equipped with a device which returns the door or window to the fully closed and latched position immediately after each manual opening.","g":"/ncc/definitions/self-closing"},{"c":"Definition","t":"Self-draining","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_ebe4825e-9ef4-4895-853d-e9d6c464c9e9","x":"A surface finish allowing water to be conveyed by gravity from the finished surface level to the membrane on the top surface of the structural substrate.","g":"/ncc/definitions/self-draining"},{"c":"Definition","t":"Sensible heat gain","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_436d62cb-940e-45b6-a431-cebde2becf3f","x":"The heat gained which causes a change in temperature.","g":"/ncc/definitions/sensible-heat-gain"},{"c":"Definition","t":"Separating element","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_23b102dc-b68e-4ce7-b324-5e740c9d8d04","x":"A barrier that exhibits fire integrity, structural adequacy, insulation, or a combination of these for a period of time under specified conditions (often in accordance with AS 1530.4).","g":"/ncc/definitions/separating-element"},{"c":"Definition","t":"Separating wall","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_c162af82-2477-499d-bdb1-39be88ffa668","x":"A wall that is common to adjoining Class 1 buildings (see Figure 7).\nFigure 7 Separating wall\nFigure Notes\nIn Volume Two a separating wall may also be known as a party wall and typically is required to be fire-resisting construction (see ABCB Housing Provisions Parts 9.2 and 9.3).","g":"/ncc/definitions/separating-wall"},{"c":"Definition","t":"Service","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_242ba975-4cdf-4b84-9f41-b8d524ee17c2","x":"For the purposes of Section J in Volume One, means a mechanical or electrical system that uses energy to provide air-conditioning, mechanical ventilation, heated water supply, artificial lighting, vertical transport and the like within a building, but which does not include—\nsystems used solely for emergency purposes; and\ncooking facilities; and\nportable appliances.","g":"/ncc/definitions/service"},{"c":"Definition","t":"Service station","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_dee326be-7bf9-476e-92f6-54c49bf5da45","x":"A garage which is not a private garage and is for the servicing of vehicles, other than only washing, cleaning or polishing.","g":"/ncc/definitions/service-station"},{"c":"Definition","t":"Shaft","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_99391afe-5794-47e4-94ab-7e9e7a83740a","x":"The walls and other parts of a building bounding—\na well, other than an atrium well; or\na vertical chute, duct or similar passage, but not a chimney or flue.","g":"/ncc/definitions/shaft"},{"c":"Definition","t":"Shared accommodation building (VIC)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_8ae20f35-99b1-4b61-b8d1-9bf91f64ed81","x":"A Class 3 building that is a boarding-house, chalet, guest house, lodging-house, backpacker accommodation or the like, or a residential part of a hotel offering shared accommodation (but is not a residential care building (Vic), a motel or a residential part of school, health-care building or detention centre) having—\nmore than one sole-occupancy unit of which any sole-occupancy unit has sleeping facilities capable of accommodating 3 or more unrelated persons; or\nsleeping facilities capable of accommodating 13 or more unrelated persons.","g":"/ncc/definitions/shared-accommodation-building-vic"},{"c":"Definition","t":"Shower area","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_6aa99639-a955-4628-bc59-dabb3bfc8118","x":"The area affected by water from a shower, including a shower over a bath and for a shower area that is—\nEnclosed – the area enclosed by walls or screens including hinged or sliding doors that contain the spread of water to within that space; or\nUnenclosed – the area where, under normal use, water from the shower rose is not contained within the shower area.","g":"/ncc/definitions/shower-area"},{"c":"Definition","t":"Shower screen","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_013ce393-1153-476d-b268-5b06c64f9232","x":"The panels, doors or windows enclosing or partially enclosing a shower area.","g":"/ncc/definitions/shower-screen"},{"c":"Definition","t":"Single leaf masonry","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_c5f81c87-c815-44df-9bfa-e4954d49ea88","x":"Outer walls constructed with a single thickness of masonry unit.","g":"/ncc/definitions/single-leaf-masonry"},{"c":"Definition","t":"Site","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_fb3536f6-7ee5-4a29-a4da-402a8e1168dc","x":"The part of the allotment of land on which a building stands or is to be erected.","g":"/ncc/definitions/site"},{"c":"Definition","t":"Sitework","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_99d8dfad-fc38-462e-a8a6-e0d4a548b2ff","x":"Work on or around a site, including earthworks, preparatory to or associated with the construction, alteration, demolition or removal of a building.","g":"/ncc/definitions/sitework"},{"c":"Definition","t":"Small arts venue (SA)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_90a8f748-ef99-4bbd-b63e-5ea34a7d4c1f","x":"The whole or the only part of a building that has a rise in storeys of not more than 2—\nin which cultural activities including live music, visual arts displays, dancing, poetry and spoken word performances are provided to the public; and\nthe floor area used as a small arts venue does not exceed 300 m2; and\nno pyrotechnics or theatrical smoke (smoke machines, hazers or the like) are used.","g":"/ncc/definitions/small-arts-venue-sa"},{"c":"Definition","t":"Small live music or arts venue (NSW)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_c8865b75-9eda-4af6-b5a9-5ff8b7fac893","x":"The whole or part of a building—\nin which cultural activities including live music, visual arts’ displays, dancing, poetry and spoken word performances are provided to the public; and\nthat has a floor area of not more than 300 square metres; and\nthat has a rise in storeys of not more than 2; and\nthat occupies not more than 2 storeys including the ground floor storey; and\nwhere pyrotechnics or theatrical smoke (smoke machines, hazers or the like) are not used.","g":"/ncc/definitions/small-live-music-or-arts-venue-nsw"},{"c":"Definition","t":"Small-scale Technology Certificate","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_38f0ea80-bd0d-4ed7-913b-cd631a812208","x":"A certificate issued under the Commonwealth Government's Small-scale Renewable Energy Scheme.","g":"/ncc/definitions/small-scale-technology-certificate"},{"c":"Definition","t":"Smoke-and-heat vent","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_425cb075-105b-486b-834a-75d429b02edc","x":"A vent, located in or near the roof for smoke and hot gases to escape if there is a fire in the building.","g":"/ncc/definitions/smoke-and-heat-vent"},{"c":"Definition","t":"Smoke-Developed Index","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_f016ff73-19ef-43df-aa04-716e96c3297b","x":"The index number for smoke as determined by an Accredited Testing Laboratory in accordance with AS/NZS 1530.3.\nNotes\nUntil the adoption of the next edition of the NCC, determination need not be undertaken by an Accredited Testing Laboratory.","g":"/ncc/definitions/smoke-developed-index"},{"c":"Definition","t":"Smoke development rate","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_2a818067-2778-48dd-bcc2-a630dcf39fd7","x":"The development rate for smoke as determined by an Accredited Testing Laboratory testing flooring materials in accordance with AS ISO 9239.1.\nNotes\nUntil the adoption of the next edition of the NCC, determination need not be undertaken by an Accredited Testing Laboratory.","g":"/ncc/definitions/smoke-development-rate"},{"c":"Definition","t":"Smoke growth rate index (SMOGRA)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_99aa38a2-f7eb-4ec9-8300-89665b9d393e","x":"The index number for smoke used in the regulation of fire hazard properties and applied to materials used as a finish, surface, lining or attachment to a wall or ceiling.\nSMOGRARC","g":"/ncc/definitions/smoke-growth-rate-index-smogra"},{"c":"Definition","t":"Solar admittance","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_153f21fa-ec15-45c3-a716-b675e707f2e7","x":"The fraction of incident irradiance on a wall-glazing construction that adds heat to a building's space.","g":"/ncc/definitions/solar-admittance"},{"c":"Definition","t":"Solar Reflectance Index","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_9d98aedb-9334-46be-9e97-5c20584ebdb1","x":"The solar reflectance index calculated in accordance with ASTM E1980-11(2019).","g":"/ncc/definitions/solar-reflectance-index"},{"c":"Definition","t":"Sole-occupancy unit","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_d2c89488-8a36-464b-94f6-a91d0f5a6c9c","x":"A room or other part of a building for occupation by one or joint owner, lessee, tenant, or other occupier to the exclusion of any other owner, lessee, tenant, or other occupier and includes—\na dwelling; or\na room or suite of rooms in a Class 3 building which includes sleeping facilities; or\na room or suite of associated rooms in a Class 5, 6, 7, 8 or 9 building; or\na room or suite of associated rooms in a Class 9c building, which includes sleeping facilities and any area for the exclusive use of a resident.","g":"/ncc/definitions/sole-occupancy-unit"},{"c":"Definition","t":"Spa pool (NSW)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_cac73194-73b2-484e-908b-2aaeb23fbf32","x":"Is as defined in the Swimming Pools Act 1992.","g":"/ncc/definitions/spa-pool-nsw"},{"c":"Definition","t":"Spandrel panel","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_9ed27f83-38e9-4a4b-b17e-cd0400ee04a0","x":"For the purposes of Section J, means the opaque part of a façade in curtain wall construction which is commonly adjacent to, and integrated with, glazing.","g":"/ncc/definitions/spandrel-panel"},{"c":"Definition","t":"Special fire protection purpose (NSW)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_ac50337a-05a5-4b61-bce0-bc0bf06cf047","x":"(As per Section 100B(6) of the Rural Fires Act 1997) means any of the following purposes:\na school,\na child care centre,\na hospital (including a hospital for the mentally ill or mentally disordered),\na hotel, motel or other tourist accommodation,\na building wholly or principally used as a home or other establishment for mentally incapacitated persons,\nseniors housing within the meaning of State Environmental Planning Policy (Housing for Seniors or People with a Disability) 2004 (now SEPP (Housing) 2021),\na group home within the meaning of State Environmental Planning Policy No 9 - Group Homes (now SEPP (Housing) 2021),\na retirement village,\nany other purpose prescribed by the regulations (Rural Fires Regulation 2022).\nNotes\nFor application of this definition in the BCA, the term “school” does not include a college, university or similar tertiary educational establishment.","g":"/ncc/definitions/special-fire-protection-purpose-nsw"},{"c":"Definition","t":"Spiral stairway","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_54d7a1d6-8144-4675-a8cd-07d57f415936","x":"A stairway with a circular plan, winding around a central post with steps that radiate from a common centre or several radii (see Figures 11.2.2d and 11.2.2e in the ABCB Housing Provisions).","g":"/ncc/definitions/spiral-stairway"},{"c":"Definition","t":"Spread-of-Flame Index","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_c6eb59e3-5e4e-40fa-a1aa-0114a7b90bc2","x":"The index number for spread of flame as determined by an Accredited Testing Laboratory in accordance with AS/NZS 1530.3.\nNotes\nUntil the adoption of the next edition of the NCC, determination need not be undertaken by an Accredited Testing Laboratory.","g":"/ncc/definitions/spread-of-flame-index"},{"c":"Definition","t":"Sprinkler alarm switch","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_447d0dbd-037c-4669-9710-fc54d51cf1c0","x":"For the purposes of Specification 23, a device capable of sending an electrical signal to activate an alarm when a residential sprinkler head is activated (e.g. a flow switch).","g":"/ncc/definitions/sprinkler-alarm-switch"},{"c":"Definition","t":"Stack bonded pier","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_57a2029c-0cba-43ab-9342-f90e29b4ef0d","x":"A pier where the overlap of a masonry unit is not more than 25% of the length of the masonry unit below.","g":"/ncc/definitions/stack-bonded-pier"},{"c":"Definition","t":"Stage","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_02701ef9-5783-4b2b-af0e-4a764b0375ed","x":"A floor or platform in a Class 9b building on which performances are presented before an audience.","g":"/ncc/definitions/stage"},{"c":"Definition","t":"Stairway platform lift","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_63d6a456-87ab-4cf6-8b47-9d3b17c38d0d","x":"A power-operated device for raising or lowering people with limited mobility on a platform (with or without a chair) in the direction of a stairway.","g":"/ncc/definitions/stairway-platform-lift"},{"c":"Definition","t":"Standard Fire Test","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_75714f9c-ff9b-4e9d-9705-7ed3522e2004","x":"The Fire-resistance Tests of Elements of Building Construction as described in AS 1530.4.","g":"/ncc/definitions/standard-fire-test"},{"c":"Definition","t":"Step ramp","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_adf2f18c-adab-4ae0-a9ab-43fe4e94f2fa","x":"A ramp, other than a kerb ramp, not exceeding 190 mm in height.","g":"/ncc/definitions/step-ramp"},{"c":"Definition","t":"Stormwater","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_3fbf6b0a-89be-427e-b511-96356a70d9ed","x":"Water accumulated or discharged as a result of a rain event.","g":"/ncc/definitions/stormwater"},{"c":"Definition","t":"Storage shed (SA)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_638ea3e1-f483-40cc-9e79-5291637c5f3e","x":"A type of bulk grain storage facility similar to that illustrated in diagram (b) of Figure SA 1.","g":"/ncc/definitions/storage-shed-sa"},{"c":"Definition","t":"Storey","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_53ff3ea1-55e7-4f2a-b2b3-ca445ff64c15","x":"A space within a building which is situated between one floor level and the floor level next above, or if there is no floor above, the ceiling or roof above, but not—\na space that contains only—\na lift shaft, stairway or meter room; or\na bathroom, shower room, laundry, water closet, or other sanitary compartment; or\naccommodation intended for not more than 3 vehicles; or\na combination of the above; or\na mezzanine.","g":"/ncc/definitions/storey"},{"c":"Definition","t":"Structural adequacy","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_506ca3a8-3ffe-4b1b-93db-37266ae1fedb","x":"In relation to an FRL, means the ability to maintain stability and adequate load bearing capacity as determined by AS 1530.4.","g":"/ncc/definitions/structural-adequacy"},{"c":"Definition","t":"Structural member","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_fb1b2da0-d982-49f1-8176-6b5c3a8ad375","x":"A component or part of an assembly which provides vertical or lateral support to a building or structure.","g":"/ncc/definitions/structural-member"},{"c":"Definition","t":"Structural substrate","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_d3cc1a16-8ec1-4c83-9d06-a8c057409202","x":"The surface of a structural member to be waterproofed as required by Part F1 or F2D2(2)(a).","g":"/ncc/definitions/structural-substrate"},{"c":"Definition","t":"Sub-surface water","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_49fcb971-d792-44ac-af74-6243aa2b5b23","x":"Includes—\nall naturally occurring water, other than surface water, which is either groundwater or water which results from rainfall infiltration on the site or other infiltration from another water source; and\nwater beneath the surface of a building element, other structure, or the ground.","g":"/ncc/definitions/sub-surface-water"},{"c":"Definition","t":"Surface finish","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_f54e63b7-9207-4230-ada9-671324d1dbb6","x":"For the purposes of Section F of Volume One, is a material or flooring system directly fixed to or supported above a structural substrate.","g":"/ncc/definitions/surface-finish"},{"c":"Definition","t":"Surface water","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_02c3900f-c9bb-470b-93f4-d71555f2fea7","x":"All naturally occurring water, other than sub-surface water, which results from rainfall on or around the site or water flowing onto the site, including water that results from rainfall on the external fabric of the building and any other water that falls or flows onto the fabric from other sources.","g":"/ncc/definitions/surface-water"},{"c":"Definition","t":"Surface water seepage","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_79a6d659-3996-45da-b994-04a1c59861d1","x":"Water escaping through the surface of the ground or a building element.","g":"/ncc/definitions/surface-water-seepage"},{"c":"Definition","t":"Swimming pool","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_4cbd9e00-0622-4dfd-9de4-913c80257732","x":"Any excavation or structure containing water and principally used, or that is designed, manufactured or adapted to be principally used for swimming, wading, paddling, or the like, including a bathing or wading pool, or spa.","g":"/ncc/definitions/swimming-pool"},{"c":"Definition","t":"Tapered tread","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_56f172ae-0aac-4d17-b043-870fa7f12560","x":"A stair tread with a walking area that grows smaller towards one end.","g":"/ncc/definitions/tapered-tread"},{"c":"Definition","t":"Temporary structure (NSW)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_d3c882c3-eb34-407a-8877-a0ed073c0e2a","x":"Either—\na booth, tent or other temporary enclosure, whether or not a part of the booth, tent or enclosure is permanent; or\na mobile structure.","g":"/ncc/definitions/temporary-structure-nsw"},{"c":"Definition","t":"Temporary structure (TAS)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_dcf88aaa-f959-470d-851a-80bf038bc603","x":"Includes any–\nbooth, tent or other temporary enclosure, whether or not part of the booth, tent or enclosure is permanent; or\ntemporary seating structure; or\nother structure prescribed under the Building Act 2016.","g":"/ncc/definitions/temporary-structure-tas"},{"c":"Definition","t":"Thermal comfort level","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_49deeede-a813-43a8-a61d-cfbe54ddb6d8","x":"The level of thermal comfort in a building expressed as a PMV sensation scale.","g":"/ncc/definitions/thermal-comfort-level"},{"c":"Definition","t":"Thermal energy load","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_c055bfd1-5325-475a-8897-841728f72222","x":"The sum of the heating load and the cooling load.","g":"/ncc/definitions/thermal-energy-load"},{"c":"Definition","t":"Threshold ramp","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_547635d1-99ea-4643-beef-7ba3f33a9587","x":"A ramp located within or at a threshold.","g":"/ncc/definitions/threshold-ramp"},{"c":"Definition","t":"Total R-Value","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_bf26e61b-dbc1-4c09-b8be-ac8d936c0ac9","x":"The sum of the R-Values of the individual component layers in a composite element including any building material, insulating material, airspace, thermal bridging and associated surface resistances, expressed in m2.K/W.","g":"/ncc/definitions/total-r-value"},{"c":"Definition","t":"Total Solar Reflectance","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_f5469860-4e39-430c-8ed6-2f36855e45cc","x":"The complement of the solar absorptance.\nTSR","g":"/ncc/definitions/total-solar-reflectance"},{"c":"Definition","t":"Total System Solar Heat Gain Coefficient (SHGC)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_d629ed6c-7113-409d-a443-fcd6f2bfe0f5","x":"For the purposes of—\nVolume One, the fraction of incident irradiance on a wall-glazing construction or a roof light that adds heat to a building’s space; or\nVolume Two, the fraction of incident irradiance on glazing or a roof light that adds heat to a building’s space.\nSHGC","g":"/ncc/definitions/total-system-solar-heat-gain-coefficient-shgc"},{"c":"Definition","t":"Total System U-Value","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_17ba3969-f9a1-4cf9-a10b-da46b81e4e13","x":"The thermal transmittance of the composite element allowing for the effect of any airspaces, thermal bridging and associated surface resistances, expressed in Wm-2K-1.","g":"/ncc/definitions/total-system-u-value"},{"c":"Definition","t":"Treatment area","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_0a15b45c-4a85-4ba1-aea2-b0b36035d808","x":"An area within a patient care area such as an operating theatre and rooms used for recovery, minor procedures, resuscitation, intensive care and coronary care from which a patient may not be readily moved.","g":"/ncc/definitions/treatment-area"},{"c":"Definition","t":"Uncontrolled discharge","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_0ece1af9-d663-4f17-a7c9-bf59ebb1b1ef","x":"Any unintentional release of fluid from a plumbing and drainage system and includes leakage and seepage.","g":"/ncc/definitions/uncontrolled-discharge"},{"c":"Definition","t":"Unique wall","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_5a67f648-7ba4-43cb-8b0c-442b280a9ac2","x":"For the purposes of F1V1 in Volume One and H2V1 in Volume Two, a wall which is neither a cavity wall nor a direct fix cladding wall.","g":"/ncc/definitions/unique-wall"},{"c":"Definition","t":"Unobstructed opening","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_8681bc83-b7c7-44d1-a34e-27b92afea880","x":"For the purposes of Section 8 of the ABCB Housing Provisions, a glazed area that a person could mistake for an open doorway or clearway and walk into the glazed panel.","g":"/ncc/definitions/unobstructed-opening"},{"c":"Definition","t":"Unprotected water service","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_56e1f5e7-6da4-4064-9569-ad7051f5d07c","x":"Unprotected water service means that the water service may be contaminated from a surrounding hazard.","g":"/ncc/definitions/unprotected-water-service"},{"c":"Definition","t":"Unreinforced masonry","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_b0f783eb-597e-48b7-84d1-467958aa02e8","x":"Masonry that is not reinforced.","g":"/ncc/definitions/unreinforced-masonry"},{"c":"Definition","t":"Vapour permeance","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_6865163b-ba99-4d48-9e9b-a76b4641be1c","x":"The degree that water vapour is able to diffuse through a material, measured in µg/N.s and tested in accordance with the ASTM-E96 Procedure B – Water Method at 23°C 50% relative humidity.","g":"/ncc/definitions/vapour-permeance"},{"c":"Definition","t":"Vapour pressure","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_f659c533-7879-4c36-b557-f489e4d53b54","x":"The pressure at which water vapour is in thermodynamic equilibrium with its condensed state.","g":"/ncc/definitions/vapour-pressure"},{"c":"Definition","t":"Ventilation opening","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_28ba8cbc-7350-41a1-8bd6-8f6cedca5463","x":"An opening in the external wall, floor or roof of a building designed to allow air movement into or out of the building by natural means including a permanent opening, an openable part of a window, a door or other device which can be held open.","g":"/ncc/definitions/ventilation-opening"},{"c":"Definition","t":"Verification Method","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_a953dcf6-ebab-404f-a3f1-6d85f87ab898","x":"A test, inspection, calculation or other method that determines whether a Performance Solution complies with the relevant Performance Requirements.","g":"/ncc/definitions/verification-method"},{"c":"Definition","t":"Vessel","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_41006db4-49b2-4075-82fb-c7a6e2258636","x":"For the purposes of Volume One and Part 10.2 of the ABCB Housing Provisions, an open, pre-formed, pre-finished concave receptacle capable of holding water, usually for the purpose of washing, including a basin, sink, bath, laundry tub and the like.","g":"/ncc/definitions/vessel"},{"c":"Definition","t":"Visibility","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_44ef04b5-2f53-46b8-b07a-434eaf8993b5","x":"The maximum distance at which an object of defined size, brightness and contrast can be seen and recognised.","g":"/ncc/definitions/visibility"},{"c":"Definition","t":"Voltage","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_391b7f25-2c7a-46aa-a64e-866ee60c6651","x":"A difference of potential, measured in Volts (V) and includes extra-low voltage and low voltage.","g":"/ncc/definitions/voltage"},{"c":"Definition","t":"Volume","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_c48e7e42-1035-4c6e-a2d2-72ebb4eaf58c","x":"In relation to—\na building — the volume of the total space of the building measured above the lowest floor (including, for a suspended floor, any subfloor space), over the enclosing walls, and to the underside of the roof covering; or\na fire compartment — the volume of the total space of the fire compartment measured within the inner finished surfaces of the enclosing fire-resisting walls and/or floors, and—\nif there is no fire-resisting floor at the base of the fire compartment, measured above the finished surface of the lowest floor in the fire compartment; and\nif there is no fire-resisting floor at the top of the fire compartment, measured to the underside of the roof covering of the fire compartment; and\nif there is no fire-resisting wall, measured over the enclosing wall and if there is no enclosing wall, includes any space within the fire compartment that has a use which contributes to the fire load; or\nan atrium — the volume of the total space of the atrium measured within the finished surfaces of the bounding construction and if there is no bounding construction, within the external walls.","g":"/ncc/definitions/volume"},{"c":"Definition","t":"Waffle raft","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_1551f5ea-52bf-4b64-82ba-e7b5e6514bdf","x":"A stiffened raft with closely spaced ribs constructed on the ground and with slab panels supported between ribs.","g":"/ncc/definitions/waffle-raft"},{"c":"Definition","t":"Wall-glazing construction","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_19c6e532-03d4-4427-8f27-e4c5c01c0690","x":"For the purposes of Section J in Volume One, the combination of wall and glazing components comprising the envelope of a building, excluding—\ndisplay glazing; and\nopaque non-glazed openings such as doors, vents, penetrations and shutters.","g":"/ncc/definitions/wall-glazing-construction"},{"c":"Definition","t":"Ward area","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_d1b612a5-df98-4406-ba1e-237f837e1061","x":"That part of a patient care area for resident patients and may contain areas for accommodation, sleeping, associated living and nursing facilities.","g":"/ncc/definitions/ward-area"},{"c":"Definition","t":"Water","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_022a6a17-e1b4-412a-b84c-3ea9c214b02c","x":"For the purposes of Section F of Volume One, includes—\nsurface water; and\nsub-surface water; and\nrainwater; and\nstormwater; and\nrising damp; and\nwater services overflow; and\nsurface water seepage.","g":"/ncc/definitions/water"},{"c":"Definition","t":"Water control layer","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_943d307a-766e-4536-a9b3-c8c0a337f506","x":"A pliable building membrane or the exterior cladding when no pliable building membrane is present.","g":"/ncc/definitions/water-control-layer"},{"c":"Definition","t":"Water services overflow","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_e62493ee-5ab3-4b6a-adf9-619577f675cf","x":"Water discharged from water service referred to in the Plumbing Code of Australia not primarily drained by a sanitary drainage system or sanitary plumbing system.","g":"/ncc/definitions/water-services-overflow"},{"c":"Definition","t":"WaterMark Certification Scheme","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_0ec686ac-e08c-484f-8d57-9f41694a3c12","x":"The ABCB scheme for certifying and authorising plumbing and drainage products.","g":"/ncc/definitions/watermark-certification-scheme"},{"c":"Definition","t":"WaterMark Conformity Assessment Body (WMCAB)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_a1cb5600-5d6f-4fc5-b782-3e4f72a5a809","x":"A conformity assessment body registered with and accredited by the JAS-ANZ to conduct evaluations leading to product certification and contracted with the administering body to issue the WaterMark Licence.\nWMCAB","g":"/ncc/definitions/watermark-conformity-assessment-body-wmcab"},{"c":"Definition","t":"WaterMark Licence","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_5d6e55b6-5192-4079-a6f3-c18da9764f13","x":"A licence issued by a WaterMark Conformity Assessment Body.","g":"/ncc/definitions/watermark-licence"},{"c":"Definition","t":"WaterMark Schedule of Excluded Products","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_75dcc9b8-248e-4bd6-ae9e-6fb31c567fd0","x":"The list maintained by the administering body of products excluded from the WaterMark Certification Scheme.","g":"/ncc/definitions/watermark-schedule-of-excluded-products"},{"c":"Definition","t":"WaterMark Schedule of Products","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_eb0e589f-30f4-48d8-a266-d17d003debbf","x":"The list maintained by the administering body of products included in the WaterMark Certification Scheme, and the specifications to which the products can be certified.","g":"/ncc/definitions/watermark-schedule-of-products"},{"c":"Definition","t":"Waterproof","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_02296d09-c6a7-41f4-a398-1f059045818c","x":"The property of a material that does not allow water to penetrate through it.","g":"/ncc/definitions/waterproof"},{"c":"Definition","t":"Waterproofing system","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_9786edfd-014d-4144-bb1c-bc7b6a43aa5a","x":"A combination of elements that are required to achieve a waterproof barrier as required by H4D2 and H4D3 including substrate, membrane, bond breakers, sealants, finishes and the like.","g":"/ncc/definitions/waterproofing-system"},{"c":"Definition","t":"Water resistant","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_787642fb-810b-4dc9-8ea9-f54fcfbc19e1","x":"The property of a system or material that restricts water movement and will not degrade under conditions of water.","g":"/ncc/definitions/water-resistant"},{"c":"Definition","t":"Water sensitive materials","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_e41c3052-abe2-4231-b631-34b38b5b0ffc","x":"Materials that have an inherent capacity to absorb water vapour and include timber, plasterboard, plywood, oriented strand board and the like.","g":"/ncc/definitions/water-sensitive-materials"},{"c":"Definition","t":"Waterstop","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_2fb1baed-5210-4b6f-a0d1-49efc309b967","x":"A vertical extension of the waterproofing system forming a barrier to prevent the passage of water in a floor or other horizontal surfaces.","g":"/ncc/definitions/waterstop"},{"c":"Definition","t":"Watertight","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_402f1fae-f28c-43c1-b8bf-6752a2801a21","x":"Will not allow water to pass from the inside to the outside of the component or joint and vice versa.","g":"/ncc/definitions/watertight"},{"c":"Definition","t":"Weighted average","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_7eb5b1ee-df2f-447a-9942-c642d9ae4a8d","x":"Is calculated across the wetted surface area of a pipe, pipe fitting or plumbing fixture.","g":"/ncc/definitions/weighted-average"},{"c":"Definition","t":"WELS (WA)","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_81561b97-4cab-4533-a48f-e070682960c4","x":"Has the meaning given in the Water Efficiency Labelling and Standards Act 2005 of the Commonwealth.","g":"/ncc/definitions/wels-wa"},{"c":"Definition","t":"Wet area","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_28f0fa3d-c51f-4413-8274-97824adf4971","x":"An area within a building supplied with water from a water supply system, which includes bathrooms, showers, laundries and sanitary compartments and excludes kitchens, bar areas, kitchenettes or domestic food and beverage preparation areas.","g":"/ncc/definitions/wet-area"},{"c":"Definition","t":"Wetted surface area","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_1dbd1294-49b7-42c8-b380-116fc29bd3e0","x":"Is calculated by the total sum of diameter (D) in contact with drinking water.","g":"/ncc/definitions/wetted-surface-area"},{"c":"Definition","t":"Winders","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_4a79e839-3915-459c-9c21-77379a801832","x":"Treads within a straight flight that are used to change direction of the stair (see Explanatory Figure 1).","g":"/ncc/definitions/winders"},{"c":"Definition","t":"Window","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_48631093-d96b-4a40-a86d-7ffae028f24d","x":"Includes a roof light, glass panel, glass block or brick, glass louvre, glazed sash, glazed door, or other device which transmits natural light directly from outside a building to the room concerned when in the closed position.","g":"/ncc/definitions/window"},{"c":"Definition","t":"Yield","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_b55ba513-d19f-4821-a5c8-36e973229247","x":"The mass of a combustion product generated during combustion divided by the mass loss of the test specimen as specified in the design fire.","g":"/ncc/definitions/yield"},{"c":"Definition","t":"Zone protection","p":"Glossary","u":"/editions/ncc-2025/adopted/volume-one/1-definitions/glossary#_fdc3535a-4b9d-49c2-add5-cb0a1b466b51","x":"The installation of a backflow prevention device at the point where a water service is connected to multiple fixtures or appliances, with no backflow prevention device installed as individual protection downstream of this point.","g":"/ncc/definitions/zone-protection"},{"c":"VIC S17C15","t":"Balconies in Class 2, 3, 9a and 9c building","p":"VIC Specification 17 Fire sprinkler systems","u":"/editions/ncc-2025/adopted/volume-one/10-victoria/vic-17-fire-sprinkler-systems#_95a20ad4-ef3e-4515-b575-39603592d864","x":"Insert VIC clause S17C15 in clause S17C15 as follows:\nCovered balconies in Class 2, 3, 9a or 9c buildings must be sprinkler protected.","st":"VIC","base":"S17C15","g":"/ncc/vic-s17c15"},{"c":"VIC S18C5","t":"Balconies in Class 2 and 3 buildings","p":"VIC Specification 18 Class 2 and 3 buildings not more than 25 m in effective height","u":"/editions/ncc-2025/adopted/volume-one/10-victoria/vic-18-class-2-and-3-buildings-not-more-25-m-effective-height#_7aa0a2f3-384d-4916-aa50-de1320f28bf3","x":"Insert VIC clause S18C5 in clause S18C5 as follows:\nCovered balconies in Class 2 or 3 buildings must be sprinkler protected.","st":"VIC","base":"S18C5","g":"/ncc/vic-s18c5"},{"c":"VIC A2G2","t":"Performance Solution","p":"VIC Part A2 Compliance with the NCC","u":"/editions/ncc-2025/adopted/volume-one/10-victoria/vic-a2-compliance-ncc#_63fdd1bf-5468-48ef-9d64-e6856d60dd4c","x":"Delete clause A2G2 and insert VIC A2G2 as follows:\n(1) A Performance Solution is achieved by demonstrating—\ncompliance with all relevant Performance Requirements; or\nthe solution is at least equivalent to the Deemed-to-Satisfy Provisions.\n(2) A Performance Solution must be shown to comply with the relevant Performance Requirements through one or a combination of the following Assessment Methods:\nEvidence of suitability in accordance with Part A5 that shows the use of a material, product, plumbing and drainage product, form of construction or design meets the relevant Performance Requirements.\nA Verification Method including the following:\nThe Verification Methods provided in the NCC.\nOther Verification Methods, accepted by the appropriate authority that show compliance with the relevant Performance Requirements.\nExpert Judgement.\nComparison with the Deemed-to-Satisfy Provisions.\n(3) Where a Performance Requirement is satisfied entirely by a Performance Solution, in order to comply with (1) the following method must be used to determine the Performance Requirement or Performance Requirements relevant to the Performance Solution:\nIdentify the relevant Performance Requirements from the Section or Part to which the Performance Solution applies.\nIdentify Performance Requirements from other Sections or Parts that are relevant to any aspects of the Performance Solution proposed or that are affected by the application of the Performance Solution.\n(4) Where a Performance Requirement is proposed to be satisfied by a Performance Solution, the following steps must be undertaken:\nPrepare a performance-based design brief in consultation with relevant stakeholders.\nCarry out analysis, as proposed by the performance-based design brief.\nEvaluate results from (4)(b) against the acceptance criteria in the performance-based design brief.\nPrepare a final report that includes—\nall Performance Requirements and/or Deemed-to-Satisfy Provisions identified through A2G2(3) or A2G4(3) as applicable; and\nidentification of all Assessment Methods used; and\ndetails of steps (4)(a) to (4)(c); and\nconfirmation that the Performance Requirement has been met; and\ndetails of conditions or limitations, if any exist, regarding the Performance Solution.\n(5) A Performance Solution cannot be used to satisfy a relevant Performance Requirement for the installation of a combustible cladding product in an external wall of a—\nClass 2, 3 or 9 building with a rise in storeys of 2 that does not comply with C2D6; and\nClass 2, 3, 5, 6, 7, 8 or 9 building with a rise in storeys of 3 or more.\nLimitations\nWhere compliance with B1P1(2) or H1P1(2) is proposed to be satisfied by a Performance Solution for materials included in B1D4(a) to (f) or clauses 2.2.4(d) and 2.2.4(g) to (k) of the ABCB Housing Provisions, the Performance Solution must be—\nachieved by demonstrating the solution is at least equivalent to the Deemed-to-Satisfy Provisions in accordance with A2G2(1)(b); and\nshown to comply with the Performance Requirements through A2G2(2)(d).\nNotes\nThe limitation above does not take effect until 1 year after the adoption date for NCC 2025.","st":"VIC","base":"A2G2","g":"/ncc/vic-a2g2"},{"c":"VIC A5G4","t":"Evidence of suitability ─ Volume Three (PCA)","p":"VIC Part A5 Documentation of design and construction","u":"/editions/ncc-2025/adopted/volume-one/10-victoria/vic-a5-documentation-design-and-construction#_f27d105c-d0a5-4f5d-a88c-5eb51f26472b","x":"Delete clause A5G4 and insert VIC A5G4 as follows:\n(1) Any product that is intended for use in contact with drinking water must comply with the relevant requirements of AS/NZS 4020, verified in the form of either—\na test report provided by an Accredited Testing Laboratory, in accordance with AS/NZS 4020; or\na WaterMark Licence issued in accordance with (3), if it includes compliance with AS/NZS 4020.\n(2) Any product that contains copper alloy and is intended for use in contact with drinking water must have a weighted average lead content of not more than 0.25% verified in the form of either—\na test report provided by an Accredited Testing Laboratory, in accordance with NSF/ANSI/CAN 372; or\na WaterMark Licence issued in accordance with (3), if it includes compliance with NSF/ANSI/CAN 372.\n(3) A product of a type listed on the WaterMark Schedule of Products is deemed to be fit for its intended purpose if it has a WaterMark Licence issued in accordance with the WaterMark Scheme Rules.\n(4) A product of a type listed on the Watermark Schedule of Excluded Products requires evidence of suitability in the form of—\na current certificate issued by a certification body stating that the properties and performance of a product can meet the requirements of the PCA; or\na report issued by an Accredited Testing Laboratory that—\ndemonstrates that the product complies with the relevant requirements of the PCA; and\nsets out the tests the product has been submitted to and the results of those tests and any other relevant information that has been relied upon to demonstrate suitability for use in a plumbing or drainage installation.\n(5) Any product that is not covered by (3) or (4) must be subjected to a risk assessment in accordance with the WaterMark Scheme Rules.\n(6) Evidence to support that a design or system meets the relevant PCA Performance Requirements must be in the form of any one or any combination of the following:\nThe design or system complies with a Deemed-to-Satisfy Provision.\nThe design or system is a Performance Solution from a professional engineer or a recognised expert that—\ncertifies that the design or system complies with the relevant requirements of the PCA; and\nsets out the basis on which it is given and the extent to which relevant standards, specifications, rules, codes of practice or other publications have been relied upon.\nAny other form of documentary evidence that—\ndemonstrates that a design or system complies with the relevant requirements of the PCA; and\nsets out the basis on which it is given and the extent to which relevant standards, specifications, rules, codes of practice or other publications have been relied upon.\nNotes\nOn-site wastewater management systems larger than covered by the standards are exempt and a Performance Solution is required.\nApplications\nProducts subject to the requirements of A5G4(2) are specifically nominated in the WaterMark Schedule of Products and the WaterMark Schedule of Excluded Products.\nExemptions\nProducts that are used exclusively for non-drinking uses such as manufacturing, industrial processing, irrigation or any other uses where water is not anticipated to be used for human consumption are excluded from the requirements of A5G4(2).","st":"VIC","base":"A5G4","g":"/ncc/vic-a5g4"},{"c":"VIC B1D6","t":"Construction of buildings in flood hazard areas","p":"VIC Part B1 Structural provisions","u":"/editions/ncc-2025/adopted/volume-one/10-victoria/vic-b1-structural-provisions#_4127b7de-bd5c-412c-8b2f-1ce63a3894c9","x":"Delete clause B1D6 and insert VIC B1D6 as follows:\n(1) A Class 2 or 3 building, Class 9a health-care building, Class 9c building or Class 4 part of a building, in a flood hazard area must comply with the ABCB Standard for Construction of Buildings in Flood Hazard Areas.\n(2) The definitions of flood hazard area and freeboard in the ABCB Standard for Construction of Buildings in Flood Hazard Areas are replaced with those in VIC Schedule 1.\n(3) The definition of defined flood level in the ABCB Standard for Construction of Buildings in Flood Hazard Areas is replaced with that in Schedule 1.","st":"VIC","base":"B1D6","g":"/ncc/vic-b1d6"},{"c":"VIC C2D11","t":"Fire hazard properties","p":"VIC Part C2 Fire resistance and stability","u":"/editions/ncc-2025/adopted/volume-one/10-victoria/vic-c2-fire-resistance-and-stability#_acff6da9-9800-4da0-be65-ed3fb051a5c2","x":"Delete subclause C2D11(3) and insert VIC C2D11(3) as follows:\n(3) The requirements of (1) do not apply to a material or assembly if it is—\nplaster, cement render, concrete, terrazzo, ceramic tile or the like; or\na fire-protective covering; or\na timber-framed window; or\na solid timber handrail or skirting; or\na timber-faced door; or\nan electrical switch, socket-outlet, cover plate or the like; or\na material used for—\na roof insulating material applied in continuous contact with a substrate; or\nan adhesive; or\na damp-proof course, flashing, caulking, sealing, ground moisture barrier, or the like; or\na paint, varnish, lacquer or similar finish, other than nitro-cellulose lacquer; or\na clear or translucent roof light of glass fibre-reinforced polyester if—\nthe roof in which it is installed forms part of a single storey building required to be Type C construction; and\nthe material is used as part of the roof covering; and\nit is not closer than 1.5 m from another roof light of the same type; and\neach roof light is not more than 14 m2 in area; and\nthe area of the roof lights per 70 m2 of roof surface is not more than 14 m2; or\na face plate or neck adaptor of supply and return air outlets of an air handling system; or\na face plate or diffuser plate of light fitting and emergency exit signs and associated electrical wiring and electrical components; or\na joinery unit, cupboard, shelving, or the like; or\nan attached non-building fixture and fitting such as—\na curtain, blind, or similar decor, other than a proscenium curtain required by Specification 32; and\na whiteboard, window treatment or the like; or\ntimber treads, risers, landings and associated supporting framework installed in accordance with D3D30 where the Spread-of-Flame Index and the Smoke-Developed Index of the timber does not exceed 9 and 8 respectively.","st":"VIC","base":"C2D11","g":"/ncc/vic-c2d11"},{"c":"VIC D2D1","t":"Deemed-to-Satisfy Provisions","p":"VIC Part D2 Provision for escape","u":"/editions/ncc-2025/adopted/volume-one/10-victoria/vic-d2-provision-escape#_1077543b-13c9-49b0-91ad-baa7770feb2d","x":"Delete subclause D2D1(1) and insert VIC D2D1(1) as follows:\n(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements D1P1 to D1P6, D1P8 and D1P10 are satisfied by complying with—\nD2D2 to VIC D2D24, D3D2 to D3D31 and D4D2 to D4D13; and\nin a building containing an atrium, Part G3; and\nin a building in an alpine area, Part G4; and\nfor a building containing an occupiable outdoor area, Part G6; and\nfor additional requirements for Class 9b buildings, Part I1; and\nfor public transport buildings, Part I2; and\nfor farm sheds, Part I3.","st":"VIC","base":"D2D1","g":"/ncc/vic-d2d1"},{"c":"VIC D2D9","t":"Width of doorways in exits or paths of travel to exits","p":"VIC Part D2 Provision for escape","u":"/editions/ncc-2025/adopted/volume-one/10-victoria/vic-d2-provision-escape#_0d92f530-015d-401c-9543-d1567a1a9ff5","x":"Delete clause D2D9 and insert VIC D2D9 as follows:\n(1) In a required exit or path of travel to an exit, the unobstructed width of a doorway must be not less than—\nin patient care areas through which patients would normally be transported in beds—\nif the doorway provides access to, or from, a corridor of width—\nless than 2.2 m — 1200 mm; or\n2.2 m or greater — 1070 mm; and\nwhere the doorway referred to in (i) is fitted with two leaves and one leaf is secured in the closed position in accordance with D3D26(3)(e), the other leaf must permit an unobstructed opening not less than 800 mm wide; or\nin patient care areas in a horizontal exit — 1250 mm; or\nthe unobstructed width of each exit provided to comply with D2D8(1), (2), (3) or (4), minus 250 mm; or\nin any other case except where it opens to a sanitary compartment or bathroom — 750 mm wide.\n(2) Notwithstanding (1), in Class 3 and Class 9a residential aged care buildings, the unobstructed width of all bedroom entrance doorways must be not less than 900 mm.","st":"VIC","base":"D2D9","g":"/ncc/vic-d2d9"},{"c":"VIC D2D24","t":"Doorways to a children’s room","p":"VIC Part D2 Provision for escape","u":"/editions/ncc-2025/adopted/volume-one/10-victoria/vic-d2-provision-escape#_eb91fc0c-5f45-45ee-a5dd-296947a83366","x":"Insert VIC clause D2D24 in clause D2D24 as follows:\nIn an early childhood centre, a children’s room must—\nhave a doorway providing direct access to or form—\nan outdoor play area; or\na passage leading to an outdoor area, open space or other safe egress point; or\na fire-isolated exit; and\nwhere the children’s room accommodates more than 21 children, at least two doorways complying with (a) that are separated as far as practicable.","st":"VIC","base":"D2D24","g":"/ncc/vic-d2d24"},{"c":"VIC D3D26","t":"Operation of latch","p":"VIC Part D3 Construction of exits","u":"/editions/ncc-2025/adopted/volume-one/10-victoria/vic-d3-construction-exits#_e025e847-eb3b-40f9-beee-d9cead074da5","x":"Delete subclause D3D26(1) and insert VIC D3D26(1) as follows:\n(1) A door in a required exit, forming part of a required exit or in the path of travel to a required exit must be readily openable without a key from the side that faces a person seeking egress, by—\na single hand downward action on a single device which—\nfor a door in a required exit in an early early childhood centre that does not open to an outdoor space enclosed in accordance with G1D4 —\nis located between 1.5 m and 1.65 m above the floor; and\nreturns the door to the fully closed position immediately after each opening; and\nin all other locations, located between 900 mm and 1.1 m above the floor; and\nif serving an area required to be accessible by Part D4—\nbe such that the hand of a person who cannot grip will not slip from the handle during the operation of the latch; and\nhave a clearance between the handle and the back plate or door face at the centre grip section of the handle of not less than 35 mm and not more than 45 mm; or\na single hand pushing action on a single device which—\nfor a door in a required exit in an early childhood centre that does not open to an outdoor space enclosed in accordance with G1D4 —\nis located between 1.5 m and 1.65 m above the floor; and\nreturns the door to the full closed position immediately after each opening; and\nin all other locations, is located between 900 mm and 1.2 m above the floor.","st":"VIC","base":"D3D26","g":"/ncc/vic-d3d26"},{"c":"VIC E1D6","t":"Where sprinklers are required: Class 2 and 3 buildings other than residential care buildings","p":"VIC Part E1 Fire fighting equipment","u":"/editions/ncc-2025/adopted/volume-one/10-victoria/vic-e1-fire-fighting-equipment#_3991d93b-0747-4fc8-89eb-91464ebdd3d3","x":"Delete clause E1D6 and insert VIC E1D6 as follows:\n(1) Sprinklers are required throughout—\nA shared accommodation building; and\nIn a Class 2 or 3 building, or any multi-classified building containing a Class 2 or 3 part, if any part of the building has—\na rise in storeys of 4 or more; and\nan effective height of not more than 25 m.\n(2) The requirements of (1) do not apply to—\na residential care building; and\na Class 8 electricity network substation with a floor area not more than 200 m2 located within a multi-classified building.","st":"VIC","base":"E1D6","g":"/ncc/vic-e1d6"},{"c":"VIC F4D1","t":"Deemed-to-Satisfy Provisions","p":"VIC Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/10-victoria/vic-f4-sanitary-and-other-facilities#_6c42cdc5-d1c5-4d56-af1e-c4e5083fb0e4","x":"Delete subclause F4D1(1) and insert VIC F4D1(1) as follows:\n(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements F4P1 to F4P6 are satisfied by complying with—\nF4D2 to F4D12 and VIC F4D13; and\nfor public transport buildings, Part I2; and\nfor farm sheds, Part I3.","st":"VIC","base":"F4D1","g":"/ncc/vic-f4d1"},{"c":"VIC F4D2","t":"Facilities in residential buildings","p":"VIC Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/10-victoria/vic-f4-sanitary-and-other-facilities#_176cb371-f137-4935-a1df-7baaf273ac0f","x":"Insert VIC subclause F4D2(6) in clause F4D2 as follows:\n(6) In addition to (3) and (5), in a Class 3 and 9a residential aged care building and Class 9c building, grabrails must be provided in association with every closet pan, shower or bath utilised by residents in accordance with AS 1428.1.","st":"VIC","base":"F4D2","g":"/ncc/vic-f4d2"},{"c":"VIC F4D4","t":"Facilities in Class 3 to 9 buildings","p":"VIC Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/10-victoria/vic-f4-sanitary-and-other-facilities#_20745dae-ddf4-4d9a-9436-c428620181ab","x":"Delete subclause F4D4(9) and insert VIC F4D4(9) as follows:\n(9) A Class 9b early childhood centre, other than a restricted children’s service, must be provided with—\na kitchen or food preparation area with a kitchen sink, separate hand washing facilities, space for a refrigerator and space for cooking facilities, with—\nthe facilities protected by a door or gate with child proof latches to prevent unsupervised access to the facilities by children younger than 5 years old; and\nthe ability to facilitate supervision of children from the facilities if the early childhood centre accommodates children younger than 2 years old; and\none bath, shower or shower-bath; and\nif the centre accommodates children younger than 3 years old—\na laundry facility comprising a washtub and space in the same room for a washing machine; and\na bench type baby bath, which is within 1 m of the nappy change bench; and\na nappy changing bench which—\nis within 1 m of separate adult hand washing facilities and bench type baby bath; and\nmust be not less than 0.9 m2 in area and at a height of not less than 850 mm, but not more than 900 mm above the finished floor level; and\nmust have a space not less than 800 mm high, 500 mm wide and 800 mm deep for the storage of steps; and\nis positioned to permit a staff member changing a nappy to have visibility of the play area at all times.\nInsert VIC subclause F4D4(15) in clause F4D4 as follows:\n(15) A restricted children’s service must be provided with—\na kitchen or facilities for the preparation or cooking of food for children including washing up facilities and a space for refrigerated food storage facilities; and\nif the service accommodates children younger than 3 years of age—\na laundry facility comprising a washtub and space in the same room for a washing machine; and\na bench-type baby bath, and a nappy change bench in close proximity.","st":"VIC","base":"F4D4","g":"/ncc/vic-f4d4"},{"c":"VIC","t":"","p":"VIC Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/10-victoria/vic-f4-sanitary-and-other-facilities#id13054","x":"User group\nFacility type\nDesign occupancy\nNumber\nChildren\nCloset pans\n1 - 30\n2\n>30\nAdd 1 per 15\nWashbasins\n1 - 30\n2\n>30\nAdd 1 per 15\nNote\nUrinals are not required in a Class 9b early childhood centre.\nFacilities for use by children must be—\njunior closet pans, except that those in a restricted children’s service may be adult height toilets if they are fitted with a removable seat suitable for children and a wide and stable step in front; and\nwashbasins with a rim height not exceeding 600 mm, except that those in a restricted children’s service may be adult height washbasins if they are provided with a wide and stable step in front; and\nexcept in a restricted children’s service, accessible from both indoor and outdoor play areas; and\nin an early childhood centre, other than a restricted children’s service, the closet pans must be located in relation to children’s rooms and outdoor play spaces so that children using toilets can be observed by staff from children’s rooms and outdoor play space.","st":"VIC","base":"","g":"/ncc/vic"},{"c":"VIC F4D8","t":"Construction of sanitary compartments","p":"VIC Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/10-victoria/vic-f4-sanitary-and-other-facilities#_b42e94e0-f08e-44aa-b827-9f9094f07ca3","x":"Delete subclause F4D8(3) and insert VIC F4D8(3) as follows:\n(3) In an early childhood centre, other than a restricted children’s service, closet pans situated in a group for use by children must be separated from one another by means of a partition, which, except for the doorway, is opaque for a height of not less than 900 mm but not more than 1200 mm above the floor.","st":"VIC","base":"F4D8","g":"/ncc/vic-f4d8"},{"c":"VIC F4D13","t":"First aid rooms","p":"VIC Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/10-victoria/vic-f4-sanitary-and-other-facilities#_aa866a57-d6bc-4de1-ac96-fa4fe981ddf3","x":"Insert VIC clause F4D13 in clause F4D13 as follows:\n(1) If an assembly building or an open spectator stand accommodates more than 5000 spectators at an arena, sportsground, showground, racecourse, cricket ground, football ground, coursing ground, motor racing arena, or the like, a suitable room or rooms must be provided in accordance with VIC Table F4D13 for use by para-medical attendants for first aid purposes.\n(2) First aid rooms required by (1) must—\nbe distributed as uniformly as possible throughout the assembly building or open spectator stand; and\nbe convenient to a public road; and\nbe readily accessible from within and outside the arena or ground; and\nhave a floor area of not less than 24 m2; and\nbe provided with a suitable wash basin or sink.\nInsert VIC table (F4D13) F4D13 as follows:\nVIC Table F4D13: First aid rooms\nSpectator capacity\nNumber of first aid rooms\n5,001 to 10,000\n1\n10,001 to 15,000\n2\n15,001 to 30,000\n3\nEach extra 15,000 or part thereof\n1","st":"VIC","base":"F4D13","g":"/ncc/vic-f4d13"},{"c":"VIC F5P1","t":"Room or space heights","p":"VIC Part F5 Room heights","u":"/editions/ncc-2025/adopted/volume-one/10-victoria/vic-f5-room-heights#_d93ef86e-9b80-4062-a474-903a87078a95","x":"Delete clause F5P1 and insert VIC F5P1 as follows:\nA habitable room or space must have sufficient size to enable the room or space to fulfil its intended function.","st":"VIC","base":"F5P1","g":"/ncc/vic-f5p1"},{"c":"VIC F5V1","t":"Room or space heights","p":"VIC Part F5 Room heights","u":"/editions/ncc-2025/adopted/volume-one/10-victoria/vic-f5-room-heights#_4bede8c5-be1d-42b3-ab3b-8f4ad787d720","x":"Delete subclause F5V1(1) and insert VIC F5V1(1) as follows:\n(1) Compliance with VIC F5P1 is verified only in relation to the height of a habitable room or space where the height of habitable room or space provides an appropriate activity support level that does not unduly interfere with its intended function.","st":"VIC","base":"F5V1","g":"/ncc/vic-f5v1"},{"c":"VIC F5D1","t":"Deemed-to-Satisfy Provisions","p":"VIC Part F5 Room heights","u":"/editions/ncc-2025/adopted/volume-one/10-victoria/vic-f5-room-heights#_56cd4aab-8410-4224-bca2-cd10bb5d326e","x":"Delete clause F5D1 and insert VIC F5D1 as follows:\nWhere a Deemed-to-Satisfy Solution is proposed, Performance Requirement VIC F5P1 is satisfied by complying with F5D2 and VIC F5D3.","st":"VIC","base":"F5D1","g":"/ncc/vic-f5d1"},{"c":"VIC F5D3","t":"Class 3, 9a and 9c residential aged care buildings – size of rooms","p":"VIC Part F5 Room heights","u":"/editions/ncc-2025/adopted/volume-one/10-victoria/vic-f5-room-heights#_cc56f13e-5033-4e5a-a8c4-d0e06d262322","x":"Insert VIC clause F5D3 in clause F5D3 as follows:\nIn a residential aged care building or residential care building —\neach bedroom must have a floor area of not less than 12 m2 per occupant; and\nall other common habitable rooms (other than kitchens) must have a floor area of not less than 7.5 m2 with—\nin a Class 3 hostel or supported residential services building or Class 9c building an aggregate floor area of not less than 3.5 m2 per occupant; or\nin a Class 9a nursing home an aggregate floor area of not less than 2.5 m2 per occupant.","st":"VIC","base":"F5D3","g":"/ncc/vic-f5d3"},{"c":"VIC I4P1","t":"Communication systems","p":"VIC Part I4 Class 3 and 9a residential aged care buildings and Class 9c buildings","u":"/editions/ncc-2025/adopted/volume-one/10-victoria/vic-i4-class-3-and-9a-residential-aged-care-buildings-and-class-9c-buildings#_5b0c9bc2-5021-43de-b6c8-fece2e13a758","x":"Delete clause I4P1 and insert VIC I4P1 as follows:\nAn electronic communication system must be provided to enable residents and staff to summon assistance in habitable rooms (other than kitchens), water closets, shower rooms and bathrooms.\nApplications\nVIC I4P1 only applies to Class 3 and Class 9a residential aged care buildings and Class 9c buildings.","st":"VIC","base":"I4P1","g":"/ncc/vic-i4p1"},{"c":"VIC I4D1","t":"Deemed-to-Satisfy Provisions","p":"VIC Part I4 Class 3 and 9a residential aged care buildings and Class 9c buildings","u":"/editions/ncc-2025/adopted/volume-one/10-victoria/vic-i4-class-3-and-9a-residential-aged-care-buildings-and-class-9c-buildings#_1ff41882-5a7d-4643-b1f4-59be49da2818","x":"Delete clause I4D1 and insert VIC I4D1 as follows:\nPerformance Requirement VIC I4P1 is satisfied by complying with VIC I4D2.","st":"VIC","base":"I4D1","g":"/ncc/vic-i4d1"},{"c":"VIC I4D2","t":"Electronic communication system","p":"VIC Part I4 Class 3 and 9a residential aged care buildings and Class 9c buildings","u":"/editions/ncc-2025/adopted/volume-one/10-victoria/vic-i4-class-3-and-9a-residential-aged-care-buildings-and-class-9c-buildings#_16de0f92-21a7-4f03-bd30-c684b3bd30de","x":"Delete clause I4D2 and insert VIC I4D2 as follows:\nA communication system must—\ncontain a back-up power supply; and\nhave a control that enables the call to be cancelled manually at the point of origin only; and\nincorporate a device at the point of origin that indicates the system has operated; and\nincorporate an indication panel in the manager’s office or staff area that clearly indicates the point of origin of a call; and\nfor systems not using personal staff communication devices, have an audible tone that has a continuous signal until deactivated at the point of origin; and\nbe operational at all times; and\nhave two call points in each ensuite or combined shower/water closet with one call point located in the shower recess and the other on the wall beside the closet pan ahead of the bowl rim; and\nhave call points (other than those mentioned in (g)) which are located—\nwithin the reach of a resident whilst in bed; and\nin all common habitable rooms; and\nin all bathrooms, sanitary compartments and shower rooms where the call point must be of waterproof construction and within the reach of any fallen resident.\nApplications\nVIC I4D2 only applies to Class 3 and Class 9a residential aged care buildings and Class 9c buildings.","st":"VIC","base":"I4D2","g":"/ncc/vic-i4d2"},{"c":"WA F9D1","t":"Eaves gutter overflow","p":"WA Part F9 Changes to AS/NZS 3500.3-2021","u":"/editions/ncc-2025/adopted/volume-one/11-western-australia/wa-f9-changes-asnzs-35003-2021#_5051d1c6-6830-45d4-835f-9eb0a5a79506","x":"Delete clause F9D1 and insert WA F9D1 as follows:\nDelete clause 3.5.1 of AS/NZS 3500.3-2021 and replace with the following:\n3.5.1 General\nEaves gutter systems, including downpipes, shall be designed and installed so that water will not flow back into the building. Overflow measures may be provided in accordance with Part 7.4 of the ABCB Housing Provisions Standard.","st":"WA","base":"F9D1","g":"/ncc/wa-f9d1"},{"c":"WA F9D2","t":"Required size of vertical downpipes","p":"WA Part F9 Changes to AS/NZS 3500.3-2021","u":"/editions/ncc-2025/adopted/volume-one/11-western-australia/wa-f9-changes-asnzs-35003-2021#_4ed06f3c-84c6-4c36-a7fb-a1435e5157cc","x":"Delete clause F9D2 and insert WA F9D2 as follows:\nDelete Table 3.5.2 of AS/NZS 3500.3-2021 and replace with the following:\nInsert WA table (F9D2) F9D2 as follows:\nWA Table F9D2: Table 3.5.2 – Eaves gutter – Required size of vertical downpipe\nEffective cross-sectional area of an eaves gutter (Ae)a, b\nInternal size of vertical down pipe, mm\nGradient\nCross-section\n1:500 and steeper\nFlatter than 1:500\nCircular\nRectangle or square\n3500\n4700\n65\n65 x 50 or 95 x 45\n4200\n5600\n75\n65 x 50 or 95 x 45\n4600\n6200\n75\n75 x 50 or 95 x 45\n4800\n6400\n80\n75 x 50 or 95 x 45\n5200\n7000\n80\n100 x 50 or 95 x 45\n5900\n7900\n85\n100 x 50\n6400\n8600\n90\n100 x 50\n6600\n8900\n90\n75 x 70\n6700\n9000\n100\n75 x 70\n8200\n11000\n100\n100 x 75\n9600\n12900\n125\n100 x 75\n12800\n17100\n125\n100 x 100\n12800\n17200\n150\n100 x 100\n16000\n21500\n150\n125 x 100\n18400\n24700\n150\n150 x 100\n19200\n25800\n-\n150 x 100\n20000\n26800\n-\n125 x 125\nTable Notes\nThe effective cross-sectional area shall be obtained from Figures 3.5.4(A) and 3.5.4(B) to the nearest 100 mm2.\nRefer to AS/NZS 2179.1.","st":"WA","base":"F9D2","g":"/ncc/wa-f9d2"},{"c":"WA G1D2","t":"Swimming pools","p":"WA Part G1 Minor structures and components","u":"/editions/ncc-2025/adopted/volume-one/11-western-australia/wa-g1-minor-structures-and-components#_f20de4a1-f9ab-446f-886f-c357da79e750","x":"Delete subclause G1D2(1) and insert WA G1D2(1) as follows:\n(1) A swimming pool with a depth of water more than 300 mm and which is associated with a Class 2 or 3 building or Class 4 part of a building, must have suitable barriers to restrict access by young children to the immediate pool surrounds in accordance with—\nAS 1926.1; and\nAS 1926.2.","st":"WA","base":"G1D2","g":"/ncc/wa-g1d2"},{"c":"WA I4D1","t":"Deemed-to-Satisfy Provisions","p":"WA Part I4 Public buildings","u":"/editions/ncc-2025/adopted/volume-one/11-western-australia/wa-i4-public-buildings#_8f474149-81b6-4c75-b892-d892118e91b3","x":"Delete clause I4D1 and insert WA I4D1 as follows:\n(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements D1P1, D1P2, D1P3, D1P4, D1P6 and F6P2 are satisfied by complying with—\nPart D2, Part D3 and F6D5; and\nfor additional requirements for WA public buildings, WA Part I4.\n(2) Where a Performance Solution is proposed, the relevant Performance Requirements must be determined in accordance with A2G2(3) and A2G4(3) as applicable.","st":"WA","base":"I4D1","g":"/ncc/wa-i4d1"},{"c":"WA I4D2","t":"Application of Part","p":"WA Part I4 Public buildings","u":"/editions/ncc-2025/adopted/volume-one/11-western-australia/wa-i4-public-buildings#_6e994110-a48b-4ac1-bfe0-ee4af7270537","x":"Delete clause I4D2 and insert WA I4D2 as follows:\nThe Deemed-to-Satisfy Provisions of this Part apply to a WA public building or part of a building.","st":"WA","base":"I4D2","g":"/ncc/wa-i4d2"},{"c":"WA I4D3","t":"Additional exits","p":"WA Part I4 Public buildings","u":"/editions/ncc-2025/adopted/volume-one/11-western-australia/wa-i4-public-buildings#_4cdc23dc-093d-4ea0-bed2-bb97ff6edd4f","x":"Delete clause I4D3 and insert WA I4D3 as follows:\nIn a WA public buildings, each storey that accommodates more than 50 persons must have more than one exit from that storey.","st":"WA","base":"I4D3","g":"/ncc/wa-i4d3"},{"c":"WA I4D4","t":"Goings and risers","p":"WA Part I4 Public buildings","u":"/editions/ncc-2025/adopted/volume-one/11-western-australia/wa-i4-public-buildings#_e7b510b3-5057-4041-9126-a4f2ef7b9e21","x":"Delete clause I4D4 and insert WA I4D4 as follows:\n(1) Steps serving a WA public building must have risers not more than 180 mm and goings not less than 280 mm.\n(2) The requirements of (1) do not apply to steps in a fire-isolated stairway.","st":"WA","base":"I4D4","g":"/ncc/wa-i4d4"},{"c":"WA I4D5","t":"Handrails to ramps, flights and landings","p":"WA Part I4 Public buildings","u":"/editions/ncc-2025/adopted/volume-one/11-western-australia/wa-i4-public-buildings#_501a8531-be96-4ab2-af96-c8731407cbde","x":"Delete clause I4D5 and insert WA I4D5 as follows:\n(1) For a WA public building, handrails must be located along—\nboth sides of a ramp or flight; and\neach side of a landing, except for that part of a side that is interrupted by a ramp or flight.\n(2) The requirements of (1) do not apply to—\nhandrails referred to in D3D23; or\nhandrails located within a fire-isolated stairway or fire-isolated ramp.","st":"WA","base":"I4D5","g":"/ncc/wa-i4d5"},{"c":"WA I4D6","t":"Artificial lighting","p":"WA Part I4 Public buildings","u":"/editions/ncc-2025/adopted/volume-one/11-western-australia/wa-i4-public-buildings#_c2044e10-1c95-4658-8c1f-c12583dc8b49","x":"Delete clause I4D6 and insert WA I4D6 as follows:\n(1) Artificial lighting must be provided along the external path of travel (including steps, landings, ramps or paths) to a road or open space associated with each exit from a WA public building.\n(2) The artificial lighting system required by (1) must—\nprovide a minimum illuminance of 1 lux at ground level; and\nbe connected to circuits separate from those supplying lighting for foyers, entry porches, emergency escape passages or areas provided entry or egress to the WA public building; and\nbe connected over two circuits where two or more lights are required; and\nhave switches that are not able to be operated by members of the public.","st":"WA","base":"I4D6","g":"/ncc/wa-i4d6"},{"c":"WA I4D7","t":"Fixed seating","p":"WA Part I4 Public buildings","u":"/editions/ncc-2025/adopted/volume-one/11-western-australia/wa-i4-public-buildings#_81ed32d1-e21f-4576-9cc9-fb4e71ca274f","x":"Delete clause I4D7 and insert WA I4D7 as follows:\nWhere fixed seating in a Class 9b WA public building is arranged in more than one row—\naisles must be provided on both sides of every row that contains more than 10 seats; and\nthe number of seats in a row must not exceed 42.","st":"WA","base":"I4D7","g":"/ncc/wa-i4d7"},{"c":"NSW S20C8","t":"System monitoring","p":"NSW Specification 20 Smoke detection and alarm systems","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-20-smoke-detection-and-alarm-systems#_ed833c33-057f-4090-b31e-0922b936f15d","x":"Delete clause S20C8 and insert NSW S20C8 as follows:\nThe following installations must be connected to a fire alarm monitoring system connected to a fire station or fire station dispatch centre in accordance with AS 1670.3:\nA smoke detection system in a Class 3 building provided in accordance with S20C2(b)(i) or S20C2(b)(ii).\nA smoke detection system in a Class 9a health-care building, if the building accommodates more than 20 patients.\nA smoke detection system in a Class 9c building.\nSmoke detection in accordance with S20C6 provided to activate—\na smoke exhaust system in accordance with Specification 21; or\nsmoke-and-heat vents in accordance with Specification 22.","st":"NSW","base":"S20C8","g":"/ncc/nsw-s20c8"},{"c":"NSW S43C2","t":"Separation from classified vegetation","p":"NSW Specification 43 Bushfire protection for certain Class 9 buildings","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-43-bushfire-protection-certain-class-9-buildings#_id16446","x":"This clause has deliberately been left blank.\nS43C2 does not apply in NSW as minimum distances for an Asset Protection Zone must be determined in accordance with Planning for Bush Fire Protection.","st":"NSW","base":"S43C2","g":"/ncc/nsw-s43c2"},{"c":"NSW S43C11","t":"Supply of water for fire-fighting purposes","p":"NSW Specification 43 Bushfire protection for certain Class 9 buildings","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-43-bushfire-protection-certain-class-9-buildings#_1d3a91b4-d72b-43f6-8f7f-a23193547abc","x":"Delete clause S43C11 and insert NSW S43C11 as follows:\nWater for fire-fighting purposes must be available and consist of—\nA fire hydrant system complying with E1D2; or\nA static water supply consisting of tanks, swimming pools, dams or the like, or a combination of these, together with suitable pumps, hoses and fittings, determined in consultation with the relevant fire brigade that—\nis capable of providing the required flow rate for a period of not less than 4 hours; or\nhas a volume of 10 000 litres for each occupied building.","st":"NSW","base":"S43C11","g":"/ncc/nsw-s43c11"},{"c":"NSW S7C4","t":"Wall and ceiling linings","p":"NSW Specification 7 Fire hazard properties","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-7-fire-hazard-properties#_e36f9960-8632-4cb1-9947-dc2b50bed033","x":"Delete clause S7C4 and insert NSW S7C4 as follows:\n(1) A wall or ceiling lining system must comply with the group number specified in Table S7C4 and for buildings not fitted with a sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17 have—\na smoke growth rate index not more than 100; or\nan average specific extinction area less than 250 m2/kg.\n(2) A group number of a wall or ceiling lining and the smoke growth rate index or average specific extinction area must be determined by in accordance with AS 5637.1.\nTable S7C4 Wall and ceiling lining materials (material groups permitted)\nClass of building\nFire-isolated exits and fire control rooms\nPublic corridors\nSpecific areas\nOther areas\nClass 2 or 3, unsprinklered, excluding accommodation for the aged, people with disabilities and children\nWalls: 1\nWalls: 1, 2\nWalls: 1, 2, 3\nWalls: 1, 2, 3\nCeilings: 1\nCeilings: 1, 2\nCeilings: 1, 2, 3\nCeilings: 1, 2, 3\nClass 2 or 3, sprinklered, excluding accommodation for the aged, people with disabilities and children\nWalls: 1\nWalls: 1, 2, 3\nWalls: 1, 2, 3\nWalls: 1, 2, 3\nCeilings: 1\nCeilings: 1, 2, 3\nCeilings: 1, 2, 3\nCeilings: 1, 2, 3\nClass 3 or 9a, unsprinklered, accommodation for the aged, people with a disability, children and health-care buildings\nWalls: 1\nWalls: 1\nWalls: 1, 2\nWalls: 1, 2, 3\nCeilings: 1\nCeilings: 1\nCeilings: 1, 2\nCeilings: 1, 2, 3\nClass 3 or 9a, sprinklered, accommodation for the aged, people with a disability, children and health-care buildings\nWalls: 1\nWalls: 1, 2\nWalls: 1, 2, 3\nWalls: 1, 2, 3\nCeilings: 1\nCeilings: 1, 2\nCeilings: 1, 2, 3\nCeilings: 1, 2, 3\nClass 5, 6, 7, 8 or 9b schools, unsprinklered\nWalls: 1\nWalls: 1, 2\nWalls: 1, 2, 3\nWalls: 1, 2, 3\nCeilings: 1\nCeilings: 1, 2\nCeilings: 1, 2\nCeilings: 1, 2, 3\nClass 5, 6, 7, 8 or 9b schools, sprinklered\nWalls: 1\nWalls: 1, 2, 3\nWalls: 1, 2, 3\nWalls: 1, 2, 3\nCeilings: 1\nCeilings: 1, 2, 3\nCeilings: 1, 2, 3\nCeilings: 1 ,2, 3\nClass 9b other than schools, unsprinklered\nWalls: 1\nWalls: 1\nWalls: 1, 2\nWalls: 1, 2, 3\nCeilings: 1\nCeilings: 1\nCeilings: 1, 2\nCeilings: 1, 2, 3\nClass 9b other than schools, sprinklered\nWalls: 1\nWalls: 1, 2\nWalls: 1, 2, 3\nWalls: 1, 2, 3\nCeilings: 1\nCeilings: 1, 2\nCeilings: 1, 2, 3\nCeilings: 1, 2, 3\nClass 9c, sprinklered\nWalls: 1\nWalls: 1, 2\nWalls: 1, 2, 3\nWalls: 1, 2, 3\nCeilings: 1\nCeilings: 1, 2\nCeilings: 1, 2, 3\nCeilings: 1, 2, 3\nTable Notes\n”Sprinklered” means a building fitted with a sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17.\n”Specific areas” means within—\nfor Class 2 and 3 buildings, a sole-occupancy unit; and\nfor Class 5 buildings, open plan offices with a minimum floor dimension/floor to ceiling height ratio > 5; and\nfor Class 6 buildings, shops or other building with a minimum floor dimension/floor to ceiling height ratio > 5; and\nfor Class 9a health-care buildings, patient care areas; and\nfor Class 9b theatres and halls, etc, an auditorium; and\nfor Class 9b schools, a classroom; and\nfor Class 9c buildings, resident use area.","st":"NSW","base":"S7C4","g":"/ncc/nsw-s7c4"},{"c":"NSW","t":"","p":"NSW Specification 7 Fire hazard properties","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-7-fire-hazard-properties#id7896","x":"Material or assembly location\nFlammability Index\nSpread-of-Flame Index\nSmoke-Developed Index\nFire control rooms subject to Specification 19 and fire-isolated exits, other than a sarking-type material used in a ceiling or used as an attachment or part of an attachment to a building element. Note 1\nN/A\n0\n2\nClass 9b buildings used as an entertainment venue, a material used to cover closed back upholstered seats in any part available to the public—where smoking is permitted; or flame is exposed in connection with the preparation of meals Note 4\nN/A\n6\n5\nClass 9b buildings used as an entertainment venue, a material used as a curtain, blind or similar decor in any part available to the public. Notes 4 and 5\n6\nN/A\nN/A\nClass 9b buildings used as an entertainment venue, a material used to form a cinematograph screen. Notes 4, 5 and 6\n12\n0\n7\nClass 9b buildings used as a public hall or the like: A proscenium curtain required by Specification 32.\nN/A\n0\n3\nEscalators, moving walkways or non-required non fire-isolated stairways or pedestrian ramps subject to Specification 14.\nN/A\n0\n5\nSarking-type materials: In a fire control room subject to Specification 19 or a fire-isolated exit used in the form of an exposed wall or ceiling.\n0\nN/A\nN/A\nSarking-type materials other than in a fire control room subject to Specification 19 or a fire-isolated exit used in the form of an exposed wall or ceiling. Note 2\n5\nN/A\nN/A\nOther materials or locations and insulation materials other than Sarking-type materials. Notes 2 and 3\nN/A\n9\n8 if the Spread-of-Flame Index is more than 5\nNote\nIn a fire control room or fire-isolated stairway, a material used as an attachment or part of an attachment to a building element must, if combustible, be attached directly to a non-combustible substrate and not exceed 1 mm finished thickness.\nA material, other than one located within a fire-isolated exit or fire control room, may be covered on all faces by concrete or masonry not less than 50 mm thick, as an alternative to meeting the specified indices.\nIn the case of a composite member or assembly, the member or assembly must be constructed so that when assembled as proposed in a building—\nany material which does not comply with this Table is protected on all sides and edges from exposure to the air; and\nthe member or assembly, when tested in accordance with Specification 3, has a Spread-of-Flame Index and Smoke-Developed Index not exceeding those prescribed in this Table; and\nthe member or assembly retains the protection in position so that it prevents ignition of the material and continues to screen it from access to free air for a period of not less than 10 minutes.\nAny fire-retardant coating used in an entertainment venue to make a material comply with a required Flammability Index, Spread-of-Flame Index or Smoke-Developed Index must be certified by—\nits manufacturer or distributor—\nas approved for use with the fabric to achieve the required indices; and\nto retain its retardancy effect after a minimum of 5 commercial dry cleaning or laundering operations carried out in accordance with AS 2001.5.4, Procedure 7A, using non-phosphate ECE reference detergent A (without optical brightener); and\nthe applicator as having been carried out in accordance with the manufacturer’s specification.\nMaterials used in an entertainment venue must have a label affixed to a representative sample of each different material indicating, in legible characters—\nname of manufacturer; and\ntrade name and description of material’s composition; and\nretardant treatment (if any), name of applicator and date of application; and\nAS 1530 Part 2 and/or AS/NZS 1530 Part 3 test number and its Flammability Index, Spread-of-Flame Index and Smoke-Developed Index; and\napproved methods of cleaning.\nA cinematograph screen must have a supporting frame of metal construction.\nUser group\nFacility type\nDesign occupancy\nNumber\nMale patrons\nCloset pans\n1 - 100\n1\n101 - 300\n2\n>300\nAdd 1 per 200\nUrinals\n1 - 50\n1\n51 - 100\n2\n101 - 150\n3\n151 - 200\n4\n201 - 250\n5\n>250\nAdd 1 per 100\nWashbasins\n1 - 50\n1\n51 - 200\n2\n>200\nAdd 1 per 200\nFemale patrons\nCloset pans\n1 - 25\n1\n26 - 50\n2\n51 - 100\n3\n101 - 150\n4\n151 - 200\n5\n201 - 250\n6\n>250\nAdd 1 per 100\nWashbasins\n1 - 50\n1\n51 - 150\n2\n>150\nAdd 1 per 200\nNote\nSanitary facilities need not be provided for patrons if the total number of persons accommodated in the building is not more than 20.\nSanitary facilities need not be provided for patrons in a small live music or arts venue that is not a licensed premises.","st":"NSW","base":"","g":"/ncc/nsw"},{"c":"NSW A2G2","t":"Performance Solution","p":"NSW Part A2 Compliance with the NCC","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-a2-compliance-ncc#_a88282f9-fec7-4386-975f-d8e376628add","x":"Delete clause A2G2 and insert NSW A2G2 as follows:\n(1) A Performance Solution is achieved by demonstrating—\ncompliance with all relevant Performance Requirements; or\nthe solution is at least equivalent to the Deemed-to-Satisfy Provisions.\n(2) A Performance Solution must be shown to comply with the relevant Performance Requirements through one or a combination of the following Assessment Methods:\nEvidence of suitability in accordance with Part A5 that shows the use of a material, product, plumbing and drainage product, form of construction or design meets the relevant Performance Requirements.\nA Verification Method including the following:\nThe Verification Method provided in the NCC.\nOther Verification Method, accepted by the appropriate authority that show compliance with the relevant Performance Requirements.\nExpert Judgement.\nComparison with the Deemed-to-Satisfy Provisions.\n(3) Where a Performance Requirement is satisfied entirely by a Performance Solution, in order to comply with (1) the following method must be used to determine the Performance Requirement or Performance Requirements relevant to the Performance Solution:\nIdentify the relevant Performance Requirements from the Section or Part to which the Performance Solution applies.\nIdentify Performance Requirements from other Sections or Parts that are relevant to any aspects of the Performance Solution proposed or that are affected by the application of the Performance Solution.\n(4) Where a Performance Requirement is proposed to be satisfied by a Performance Solution, the following steps must be undertaken:\nPrepare a performance-based design brief in consultation with relevant stakeholders.\nCarry out analysis, as proposed by the performance-based design brief.\nEvaluate results from (4)(b) against the acceptance criteria in the performance-based design brief.\nPrepare a final report that includes—\nall Performance Requirements and/or Deemed-to-Satisfy Provisions identified through A2G2(3) or A2G4(3) as applicable; and\nidentification of all Assessment Methods used; and\ndetails of steps (4)(a) to (4)(c); and\nconfirmation that the Performance Requirement has been met; and\ndetails of conditions or limitations, if any exist, regarding the Performance Solution.","st":"NSW","base":"A2G2","g":"/ncc/nsw-a2g2"},{"c":"NSW A5G3","t":"Evidence of suitability ─ Volumes One and Two (BCA)","p":"NSW Part A5 Documentation of design and construction","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-a5-documentation-design-and-construction#_759bda03-7ca4-4aaf-9a7c-7365af32bec1","x":"Delete clause A5G3 and insert NSW A5G3 as follows:\n(1) Subject to A5G5, NSW A5G6, A5G7 and A5G9, evidence to support that the use of a material, product, form of construction or design meets a Performance Requirement or a Deemed-to-Satisfy Provision may be in the form of any one, or any combination of the following:\nA current CodeMark Australia or CodeMark Certificate of Conformity.\nA current Certificate of Accreditation.\nA current certificate, other than a certificate described in (a) and (b), issued by a certification body stating that the properties and performance of a material, product, form of construction or design fulfil specific requirements of the BCA.\nA report issued by an Accredited Testing Laboratory that—\ndemonstrates that a material, product or form of construction fulfils specific requirements of the BCA; and\nsets out the tests the material, product or form of construction has been subjected to and the results of those tests and any other relevant information that has been relied upon to demonstrate it fulfils specific requirements of the BCA.\nA certificate or report from a professional engineer or other appropriately qualified person that—\ncertifies that a material, product, form of construction or design fulfils specific requirements of the BCA; and\nsets out the basis on which it is given and the extent to which relevant standards, specifications, rules, codes of practice or other publications have been relied upon to demonstrate it fulfils specific requirements of the BCA.\nAnother form of documentary evidence, such as but not limited to a Product Technical Statement, that—\ndemonstrates that a material, product, form of construction or design fulfils specific requirements of the BCA; and\nsets out the basis on which it is given and the extent to which relevant standards, specifications, rules, codes of practice or other publications have been relied upon to demonstrate it fulfils specific requirements of the BCA.\n(2) Evidence to support that a calculation method complies with an ABCB protocol may be in the form of any one, or any combination of the following:\nA certificate from a professional engineer or other appropriately qualified person that—\ncertifies that the calculation method complies with a relevant ABCB protocol; and\nsets out the basis on which it is given and the extent to which relevant standards, specifications, rules, codes of practice and other publications have been relied upon.\nAnother form of documentary evidence that correctly describes how the calculation method complies with a relevant ABCB protocol.\nApplications\nNSW A5G3 is only applicable to NCC Volumes One and Two (BCA).\nNotes\nCurrent documentary evidence, such as a certificate or report, containing references to NCC 2019 provisions remains valid despite amended provision references in NCC 2022 and subsequent editions, subject to technical requirements remaining the same between editions.","st":"NSW","base":"A5G3","g":"/ncc/nsw-a5g3"},{"c":"NSW A5G6","t":"Fire hazard properties and combustibility","p":"NSW Part A5 Documentation of design and construction","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-a5-documentation-design-and-construction#_1d480742-da7e-49e1-bcb2-ff4a1e05b1ed","x":"Delete clause A5G6 and insert NSW A5G6 as follows:\n(1) Subject to (3), where a Deemed-to-Satisfy Provision requires a building material, component, or assembly to have a fire hazard property it must be determined as follows:\nFor critical radiant flux and smoke development rate, in accordance with AS ISO 9239.1.\nFor Smoke-Developed Index and Spread-of-Flame Index, in accordance with AS/NZS 1530.3.\nFor group number, average specific extinction area and smoke growth rate index (SMOGRARC), in accordance with AS 5637.1.\nFor Flammability Index, in accordance with AS 1530.2.\n(2) Subject to (4) and (5), where a Deemed-to-Satisfy Provision requires a building material, component, or assembly to be non-combustible, its combustibility may be determined in accordance with AS 1530.1 or C2D10(5).\n(3) A building material, component, or assembly is deemed to have a fire hazard property if—\nit is identical with a prototype that has been tested in accordance with (1) and the fire hazard property achieved by the prototype is confirmed in a report that—\ndescribes the method and conditions of the test and form of construction of the tested prototype in full; and\nconfirms that the application of restraint to the prototype complies with the test standard; or\nit differs in only a minor degree from a prototype tested under (a) and a report—\nconfirms that the building product, component, or assembly can achieve the fire hazard property despite the minor departures from the tested prototype; and\ndescribes the materials, construction, conditions of restraint and other limitations which are necessary to achieve the fire hazard property.\n(4)  A building material is deemed to be non-combustible if—\nit is identical with a material that has been tested in accordance with AS 1530.1 and has not been deemed combustible; or\nit is deemed non-combustible in accordance with C2D10(5); or\nit differs in only a minor degree to a material tested under (a) and a report—\nconfirms that the material can achieve the attribute of being non-combustible despite the minor departures from the tested material; and\ndescribes any limitations which are necessary to achieve the attribute of being non-combustible.\n(5) A building component or assembly is deemed to be non-combustible if it is constructed wholly of materials that are deemed to be non-combustible.","st":"NSW","base":"A5G6","g":"/ncc/nsw-a5g6"},{"c":"NSW A6G7","t":"Class 6 buildings","p":"NSW Part A6 Building classification","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-a6-building-classification#_7ff9dfae-bcbd-4884-b133-ca2716412f34","x":"Delete clause A6G7 and insert NSW A6G7 as follows:\nA Class 6 building is a shop or other building for sale of goods by retail or the supply of services direct to the public, including—\nan eating room, cafe, restaurant, milk or soft drink bar; or\na dining room, bar, shop or kiosk part of a hotel or motel; or\na hairdresser’s or barber’s shop, public laundry, or undertaker’s establishment; or\nmarket or sale room, showroom, or service station; or\nsmall live music or arts venue.","st":"NSW","base":"A6G7","g":"/ncc/nsw-a6g7"},{"c":"NSW B1P1","t":"Structural reliability","p":"NSW Part B1 Structural provisions","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-b1-structural-provisions#_eaf925a3-3dbf-4dc7-9a38-357ff74cb88a","x":"Delete clause B1P1 and insert NSW B1P1 as follows:\n(1) By resisting the actions to which it may reasonably be expected to be subjected, a building or structure, during construction and use, with appropriate levels of reliability, must—\nperform adequately under all reasonably expected design actions; and\nwithstand extreme or frequently repeated design actions; and\nbe designed to sustain local damage, with the structural system as a whole remaining stable and not being damaged to an extent disproportionate to the original local damage; and\navoid causing damage to other properties.\n(2) The actions to be considered to satisfy (1) and (2) include but are not limited to—\npermanent actions (dead loads) including, for a Class 7b building, an additional notional permanent roof load of not less than 0.15 kPa to support the addition of solar photovoltaic panels; and\nimposed actions (live loads arising from occupancy and use); and\nwind action; and\nearthquake action; and\nsnow action; and\nliquid pressure action; and\nground water action; and\nrainwater action (including ponding action); and\nearth pressure action; and\ndifferential movement; and\ntime dependent effects (including creep and shrinkage); and\nthermal effects; and\nground movement caused by—\nswelling, shrinkage or freezing of the subsoil; and\nlandslip or subsidence; and\nsiteworks associated with the building or structure; and\nconstruction activity actions; and\ntermite actions.\nExemptions\nThe requirement for an additional notional permanent roof load to support photovoltaic panels in NSW B1P1(3)(a) does not apply to a Class 7b building—\nwhere 100% of the roof area is shaded for more than 70% of daylight hours; or\nwith a roof area of not more than 55 m2; or\nwhere more than 50% of the roof area is used as a terrace, carpark, roof garden, roof light or the like.","st":"NSW","base":"B1P1","g":"/ncc/nsw-b1p1"},{"c":"NSW B1P4","t":"Structural resistance","p":"NSW Part B1 Structural provisions","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-b1-structural-provisions#_e940b7af-1660-4710-8291-d8f5b6170d5a","x":"Insert NSW clause B1P4 in clause B1P4 as follows:\nThe structural resistance of materials and forms of construction must be determined using five percentile characteristics material properties with appropriate allowance for—\nknown construction activities; and\ntype of material; and\ncharacteristics of the site; and\nthe degree of accuracy inherent in the methods used to assess the structural behaviour; and\naction effects arising from the differential settlement of foundations, and from restrained dimensional changes due to temperature, moisture, shrinkage, creep and similar effects.","st":"NSW","base":"B1P4","g":"/ncc/nsw-b1p4"},{"c":"NSW B1V1","t":"Structural reliability","p":"NSW Part B1 Structural provisions","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-b1-structural-provisions#_460740dc-5f19-4dec-ba0f-3291d91025ee","x":"Delete clause B1V1 and insert NSW B1V1 as follows:\n(1) This Verification Method is applicable to components with a resistance coefficient of variation of at least 10% and not more than 40%.\n(2) Where a component has a calculated resistance coefficient of variation of less than 10%, then a minimum value of 10% must be used.\n(3) Compliance with B1P1 and B1P2 is verified for the design of a structural component for strength where—\nthe capacity reduction factor [formula] satisfies [formula] , where [formula] are capacity reduction factors for all relevant actions and must contain at least permanent (G), imposed (Q) and wind (W) actions; and\nthe capacity reduction factors [formula] are calculated for target reliability indices for permanent action [formula] , for imposed action [formula] , for wind action [formula] ,… in accordance with the equation: [formula] , where—\n[formula] ; and\n[formula] , [formula] , where—\n[formula] = ratio of mean resistance to nominal; and\n[formula] = ratio of mean action to nominal; and\n[formula] = correction factor for action; and\n[formula] = correction factor for resistance; and\n[formula] = coefficient of variation of the appropriate action as given in NSW Table B1V1a; and\n[formula] = coefficient of variation of the resistance; and\n[formula] = appropriate load factor for the action as given in AS/NZS 1170.0; and\n[formula] = capacity factor for the appropriate action; and\nthe annual target reliability indices [formula] are established as follows:\nFor situations where it is appropriate to compare an equivalent Deemed-to-Satisfy product, a resistance model must be established for the equivalent Deemed-to-Satisfy product and [formula] must be calculated for the equivalent Deemed-to-Satisfy product in accordance with the equation given at (b).\nThe target reliability indices [formula] thus established, must be not less than those given in NSW Table B1V1b minus 0.5.\nFor situations where it is not appropriate to compare with an equivalent Deemed-to-Satisfy product, the target reliability index [formula] must be as given in NSW Table B1V1b.\n(4) The resistance model for the component must be established by taking into account variability due to material properties, fabrication and construction processes and structural modelling.\nInsert NSW table (B1V1a) B1V1 as follows:\nNSW Table B1V1a: Annual action models\nDesign action\nRatio of mean action to nominal\nCoefficient of variation of the action\nPermanent action ( [formula] )\n[formula] |\n[formula] | Imposed action ( [formula] )\n[formula] |\n[formula] | Wind action ( [formula] ) (non-cyclonic)\n[formula] |\n[formula] | Wind action ( [formula] ) (cyclonic)\n[formula] |\n[formula] | Snow action ( [formula] )\n[formula] |\n[formula] | Earthquake action ( [formula] )\n[formula] |\n[formula] Insert NSW table (B1V1b) B1V1 as follows:\nNSW Table B1V1b: Annual target reliability indices\nType of action\nTarget reliability index [formula] | Permanent action\n4.3\nImposed action\n4.0\nWind, snow and earthquake action\n3.7\nTable Notes\nTable B1V1b is applicable for components that exhibit brittle failure similar to concrete as specific in AS 3600.\nFor components with creep characteristics similar to timber as specified in AS 1720.1, the target reliability index for permanent action must be increased to 5.0.\nThe above target reliability indices are based on materials or systems that exhibit creep or brittle failure similar to timber or concrete.\nTable B1V1b may also be applicable to materials or systems that exhibit creep or brittle failure differently to steel, timber or concrete provided the creep or brittle nature of the material or system are properly accounted for in the design model.\nThe above target reliability indices are also applicable for materials or systems that exhibit ductile failure characteristics.","st":"NSW","base":"B1V1","g":"/ncc/nsw-b1v1"},{"c":"NSW B1D1","t":"Deemed-to-Satisfy Provisions","p":"NSW Part B1 Structural provisions","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-b1-structural-provisions#_53e43ea3-8da9-412e-b1c4-6cb9923240ae","x":"Delete subclause B1D1(1) and insert NSW B1D1(1) as follows:\n(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements NSW B1P1, B1P2, B1P3 and NSW B1P4 are satisfied by complying with B1D2 to B1D6.","st":"NSW","base":"B1D1","g":"/ncc/nsw-b1d1"},{"c":"NSW C1V3","t":"Fire spread via external walls","p":"NSW Part C1 Fire resistance","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-c1-fire-resistance#_d977a5d0-9786-4df0-a816-0abb665ab73e","x":"Delete clause C1V3 and insert NSW C1V3 as follows:\nCompliance with C1P2 to avoid the spread of fire via the external wall of a building is verified when—\ncompliance with C1P2(1)(c) to avoid the spread of fire between buildings, where applicable, is verified in accordance with C1V1 or C1V2, as appropriate; and\nthe external wall system—\nhas been tested for external wall (EW) performance in accordance with AS 5113; and\nhas achieved the classification EW; and\nif containing a cavity, incorporates cavity barriers and these cavity barriers have been included in the test performed under (i) at the perimeter of each floor; and\nin a building of Type A construction, the building is protected throughout by a sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17 and has—\nsprinkler protection to balconies, patios and terraces, and where overhead sprinkler coverage is not achieved alongside the external wall, sidewall sprinkler heads are provided at the external wall for the extent of the balcony, patio or terrace where overhead sprinkler coverage is not achieved; and\nfor a building with an effective height more than 25 m—\nmonitored stop valves provided at each floor level arranged to allow the isolation of the floor level containing the stop valve while maintaining protection to the remainder of the building; and\nthe sprinkler system being capable of providing sufficient flow to serve the design area required by AS 2118.1 for the relevant hazard class on each floor level plus the design area required by AS 2118.1 for the floor level above, except where the former level is either the floor level below the uppermost roof, or any floor level that is wholly below ground; and\nin a building of Type B construction, the building is—\na Class 5, 6, 7 or 8 building or Class 4 part of a building; or\na Class 2, 3 or 9 building that—\nis protected throughout by a sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17; or\nhas any openings in external walls separated by a slab or other horizontal construction complying with C3D7(1)(d) as if the building were of Type A construction.","st":"NSW","base":"C1V3","g":"/ncc/nsw-c1v3"},{"c":"NSW C2D11","t":"Fire hazard properties","p":"NSW Part C2 Fire resistance and stability","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-c2-fire-resistance-and-stability#_11526a0c-00c8-4c85-8f5e-cbe9ffbb43d5","x":"Delete clause C2D11 and insert NSW C2D11 as follows:\n(1) The fire hazard properties of the following internal linings, materials and assemblies within a Class 2 to 9 building must comply with Specification 7:\nFloor linings and floor coverings.\nWall linings and ceiling linings.\nAir-handling ductwork.\nLift cars.\nIn Class 9b buildings used as—\nan entertainment venue, a material used to cover closed back upholstered seats; and\na public hall or the like, a proscenium curtain required by Specification 32.\nEscalators, moving walkways and non-required non fire-isolated stairways or pedestrian ramps subject to Specification 14.\nSarking-type materials.\nAttachments to floors, ceilings, internal walls, common walls, fire walls and to internal linings of external walls.\nOther materials including insulation materials other than sarking-type materials.\n(2) Paint or fire-retardant coatings must not be used in order to make a material comply with a required fire hazard property, except in respect of a material referred to in NSW Specification 7, NSW Table S7C7 and to which Notes 4 and 5 are applicable.\n(3) The requirements of (1) do not apply to a material or assembly if it is—\nplaster, cement render, concrete, terrazzo, ceramic tile or the like; or\na fire-protective covering; or\na timber-framed window; or\na solid timber handrail or skirting; or\na timber-faced door; or\nan electrical switch, socket-outlet, cover plate or the like; or\na material used for—\na roof insulating material applied in continuous contact with a substrate; or\nan adhesive; or\na damp-proof course, flashing, caulking, sealing, ground moisture barrier, or the like; or\na paint, varnish, lacquer or similar finish, other than nitro-cellulose lacquer; or\na clear or translucent roof light of glass fibre-reinforced polyester if—\nthe roof in which it is installed forms part of a single storey building required to be Type C construction; and\nthe material is used as part of the roof covering; and\nit is not closer than 1.5 m from another roof light of the same type; and\neach roof light is not more than 14 m2 in area; and\nthe area of the roof lights per 70 m2 of roof surface is not more than 14 m2; or\na face plate or neck adaptor of supply and return air outlets of an air handling system; or\na face plate or diffuser plate of light fitting and emergency exit signs and associated electrical wiring and electrical components; or\na joinery unit, cupboard, shelving, or the like; or\nan attached non-building fixture and fitting such as—\na curtain, blind, or similar decor, other than—\na proscenium curtain required by Specification 32; or\nin a Class 9b building used as an entertainment venue, a material regulated under NSW Table S7C7; and\na whiteboard, window treatment or the like; or\ntimber treads, risers, landings and associated supporting framework installed in accordance with D3D30 where the Spread-of-Flame Index and the Smoke-Developed Index of the timber does not exceed 9 and 8 respectively; or\nany other material that does not significantly increase the hazards of fire.","st":"NSW","base":"C2D11","g":"/ncc/nsw-c2d11"},{"c":"NSW C3D6","t":"Class 9 buildings","p":"NSW Part C3 Compartmentation and separation","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-c3-compartmentation-and-separation#_5230799f-7e8b-4e14-827a-4967738585cd","x":"Delete subclause C3D6(3) and insert NSW C3D6(3) as follows:\n(3) A Class 9c building must comply with the following:\nA building must be divided into areas not more than 500 m2 by smoke proof walls complying with Specification 11.\nA fire compartment must be separated from the remainder of the building by fire walls and notwithstanding C3D8 and Specification 5, floors with an FRL of not less than 60/60/60.\nExcept for walls provided in accordance with (3)(a) and (b), non-loadbearing internal walls, and if a building is of Type C construction — all internal walls, between and bounding sole-occupancy units and bounding a public corridor in a resident use area must:\nbe lined on each side with standard grade plasterboard not less than 13 mm thick or a material with at least an equivalent level of fire protection; and\nif provided with cavity insulation, contain only non-combustible insulation; and\nextend to the underside of—\nthe floor next above; or\na ceiling lined with standard grade plasterboard not less than 13 mm thick or an equivalent non-combustible material; or\na non-combustible roof covering; and\nnot incorporate any penetrations above door head height unless the penetrations are adequately stopped to prevent the free passage of smoke; and\nbe smoke sealed with intumescent putty or other suitable material at any construction joint, space or the like between the top of the wall and the floor, ceiling or roof.\nLoad bearing internal walls must comply with the requirements of Specification 5 and (c)(ii), (iii), (iv) and (v) above.\nAncillary use areas containing equipment or materials that are a high potential fire hazard, must be separated from the sole-occupancy units by smoke proof walls complying with Specification 11.\nThe ancillary use areas referred to in (e) include, but are not limited to, the following:\nA kitchen and related food preparation areas having a combined floor area of more than 30 m2.\nA laundry, where items of equipment are of the type that are potential fire sources (e.g. gas fire dryers).\nStorage rooms greater than 10 m2 used predominantly for the storage of administrative records.\nOpenings in fire walls must be protected as follows:\nDoorways — self-closing or automatic closing –/60/30 fire doors.\nWindows — automatic or permanently fixed closed –/60/– fire windows or –/60/– automatic fire shutters.\nOther openings — construction having an FRL not less than –/60/–.","st":"NSW","base":"C3D6","g":"/ncc/nsw-c3d6"},{"c":"NSW C4D12","t":"Bounding construction: Class 2 and 3 buildings and Class 4 parts","p":"NSW Part C4 Protection of openings","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-c4-protection-openings#_1db2b0fc-3cd5-4784-879c-0f6b21060b3d","x":"Delete subclause C4D12(4) and insert NSW C4D12(4) as follows:\n(4) Except as provided for in NSW C4D12(5), protection for a doorway required under (1), (2) or (3) must be at least—\nin a building of Type A construction — a self-closing –/60/30 fire door; and\nin a building of Type B or C construction — a self-closing, tight fitting, solid core door not less than 35 mm thick.\nDelete subclause C4D12(5) and insert NSW C4D12(5) as follows:\n(5) In a Class 3 building used as a residential care building protected with a sprinkler system complying with Specification 17, protection for a doorway must be at least a tight fitting solid core door not less than 35 mm thick that is—\nself-closing; or\nfitted with a free-arm action closing device which closes the door or causes the door to remain closed (without preventing manual re-opening), upon the detection of smoke caused by a smoke detector located within the room.\nInsert NSW subclause C4D12(10) in clause C4D12 as follows:\n(10) In a Class 9b building used as an entertainment venue, openings in construction required to separate one space from another must be protected in accordance with C4D5.","st":"NSW","base":"C4D12","g":"/ncc/nsw-c4d12"},{"c":"NSW D2D1","t":"Deemed-to-Satisfy Provisions","p":"NSW Part D2 Provision for escape","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-d2-provision-escape#_a4712102-c0f6-44d8-8fcc-c3bfe6c3a1b8","x":"Delete subclause D2D1(1) and insert NSW D2D1(1) as follows:\n(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements D1P1 to D1P6, D1P8 to D1P10 are satisfied by complying with—\nD2D2 to D2D23, D3D2 to NSW D3D32, D4D2 to D4D13; and\nin a building containing an atrium, Part G3; and\nin a building in an alpine area, Part G4; and\nfor a building containing an occupiable outdoor area, Part G6; and\nfor additional requirements for Class 9b buildings, Part I1; and\nfor public transport buildings, Part I2; and\nfor farm sheds, Part I3.","st":"NSW","base":"D2D1","g":"/ncc/nsw-d2d1"},{"c":"NSW D2D3","t":"Number of exits required","p":"NSW Part D2 Provision for escape","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-d2-provision-escape#_afb2a057-e6ca-4ed6-9b11-5e5d99216197","x":"Delete subclause D2D3(4) and insert NSW D2D3(4) as follows:\n(4) Class 9 buildings—\nIn addition to any horizontal exit, not less than 2 exits must be provided from the following:\nEach storey if the building has a rise in storeys of more than 6 or an effective height of more than 25 m.\nAny storey which includes a patient care area in a Class 9a health-care building.\nAny storey that contains sleeping areas in a Class 9c building.\nAny storey used as a Class 9b early childhood centre, or any Class 9b early childhood centre which forms part of a storey.\nEach storey in a primary or secondary school with a rise in storeys of 2 or more.\nAny storey or mezzanine that accommodates more than 50 persons, calculated under D2D18.\nAny storey or mezzanine within an auditorium in an entertainment venue.\nThe requirements of (a) do not apply to a part of a storey that—\nis a plant room, machinery room, storeroom, lift-machine room or the like; and\nis provided with direct egress to a road, open space or a fire-isolated exit complying with D2D12(2); and\nsatisfies D2D5 by the provision of 1 exit.","st":"NSW","base":"D2D3","g":"/ncc/nsw-d2d3"},{"c":"NSW D2D8","t":"Width of exits and paths of travel to exits","p":"NSW Part D2 Provision for escape","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-d2-provision-escape#_21737401-aae6-4292-99cb-d33d0d6ba8d7","x":"Insert NSW subclause D2D8(5) in clause D2D8 as follows:\n(5) In a Class 9b building used as an entertainment venue —\nthe aggregate width must be not less than 2 m plus 500 mm for every 50 persons or part in excess of 200; and\nD2D8(1), (2) and (3) do not apply; and\nwhere one or more paths of travel merge, the width of the combined path of travel must be not less than the sum of the required widths of those paths of travel; and\nthe required widths of those paths of travel connecting the exits from the building to a public road or open space must comply with (c); or","st":"NSW","base":"D2D8","g":"/ncc/nsw-d2d8"},{"c":"NSW D2D9","t":"Width of doorways in exits or paths of travel to exits","p":"NSW Part D2 Provision for escape","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-d2-provision-escape#_b967e065-2d31-474a-8504-14456236cc1c","x":"Delete clause D2D9 and insert NSW D2D9 as follows:\nIn a required exit or path of travel to an exit, the unobstructed width of a doorway must be not less than—\nin patient care areas through which patients would normally be transported in beds—\nif the doorway provides access to, or from, a corridor of width—\nless than 2.2 m — 1200 mm; or\n2.2 m or greater — 1070 mm; and\nwhere the doorway referred to in (i) is fitted with two leaves and one leaf is secured in the closed position in accordance with D3D26(3)(e), the other leaf must permit an unobstructed opening not less than 800 mm wide; or\nin patient care areas in a horizontal exit — 1250 mm; or\nthe unobstructed width of each exit provided to comply with D2D8(1), (2), (3) or (4), minus 250 mm; or\nin a Class 9c building, 800 mm, except—\nin resident use areas the minimum unobstructed width must be 870 mm; and\nfor doorways leading from a public corridor to a sole-occupancy unit the minimum unobstructed width must be 1070 mm; and\nwhere the doorway is fitted with two leaves and one leaf is secured in the closed position in accordance with D3D26(3)(e), the other leaf must permit an unobstructed opening not less than 870 mm wide in resident use areas and 800 mm wide in non-resident use areas; or\nin a Class 9b building used as an entertainment venue —\nin parts of the building used by the public, the width of the required exit or path of travel, and the unobstructed width of each doorway must not be less than 1 m and not more than 3 m; and\nin other parts of the building, doorways must comply with NSW D2D9; or\nin any other case except where it opens to a sanitary compartment or bathroom — 750 mm wide.","st":"NSW","base":"D2D9","g":"/ncc/nsw-d2d9"},{"c":"NSW D2D15","t":"Discharge from exits","p":"NSW Part D2 Provision for escape","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-d2-provision-escape#_c47f6f63-cf4c-4bdc-8346-fbde79a5a235","x":"Delete subclause D2D15(6) and insert NSW D2D15(6) as follows:\n(6) In a Class 9b building used as an entertainment venue, at least half of the required number of exits from each storey or mezzanine, and at least half of the aggregate width of such exits must discharge otherwise than through the main entrance, or the area immediately adjacent to the main entrance to the building.","st":"NSW","base":"D2D15","g":"/ncc/nsw-d2d15"},{"c":"NSW D3D1","t":"Deemed-to-Satisfy Provisions","p":"NSW Part D3 Construction of exits","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-d3-construction-exits#_21eb273d-7e5f-42dd-aa1f-d634a8b926c6","x":"Delete subclause D3D1(1) and insert NSW D3D1(1) as follows:\n(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements D1P1 to D1P6 and D1P8 to D1P10 are satisfied by complying with—\nD2D2 to D2D23, D3D2 to NSW D3D32 and D4D2 to D4D13; and\nin a building containing an atrium, Part G3; and\nin a building in an alpine area, Part G4; and\nfor a building containing an occupiable outdoor area, Part G6; and\nfor additional requirements for Class 9b buildings, Part I1; and\nfor public transport buildings, Part I2; and\nfor farm buildings and farm sheds, Part I3.","st":"NSW","base":"D3D1","g":"/ncc/nsw-d3d1"},{"c":"NSW D3D2","t":"Application of Part","p":"NSW Part D3 Construction of exits","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-d3-construction-exits#_8f22ec81-98b8-4953-b5c4-4486514627c4","x":"Delete clause D3D2 and insert NSW D3D2 as follows:\n(1) Except for—\nD3D14, D3D15(a), D3D17, D3D18, D3D19, D3D20, D3D22(5), D3D22(6), D3D26 and D3D29, the Deemed-to-Satisfy Provisions of this Part do not apply to the internal parts of a sole-occupancy unit in a Class 3 building; and\nD3D14, D3D15(a), D3D17, D3D18, D3D19, D3D20, D3D22(5), D3D22(6), D3D23 and D3D29, the Deemed-to-Satisfy Provisions of this Part do not apply to the internal parts of a sole-occupancy unit in a Class 2 building or Class 4 part of a building.\n(2) In a Class 9b building used as an entertainment venue —\nClauses NSW D3D14(1)(i), (j), and (k), NSW D3D16(b)(i), NSW D3D18(1)(d), and NSW D3D24(2)(e) apply to only those parts of the building used by the public; and\nthe general requirements of Part D3 apply to all other parts of the building.","st":"NSW","base":"D3D2","g":"/ncc/nsw-d3d2"},{"c":"NSW D3D14","t":"Goings and risers","p":"NSW Part D3 Construction of exits","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-d3-construction-exits#_843ba999-685f-4296-b0cd-9f206938b55a","x":"Delete subclause D3D14(1) and insert NSW D3D14(1) as follows:\n(1) A stairway must have—\nnot more than 18 and not less than 2 risers in each flight; and\ngoing (G), riser (R) and quantity (2R + G) in accordance with Table D3D14, except as permitted by (2) and (3); and\nconstant goings and risers throughout each flight, except as permitted by (2) and (3), and the dimensions of goings (G) and risers (R) in accordance with (1)(b) are considered constant if the variation between—\nadjacent risers, or between adjacent goings, is no greater than 5 mm; and\nthe largest and smallest riser within a flight, or the largest and smallest going within a flight, does not exceed 10 mm; and\nrisers which do not have any openings that would allow a 125 mm sphere to pass through between the treads; and\ntreads which have—\na surface with a slip-resistance classification not less than that listed in Table D3D15 when tested in accordance with AS 4586; or\na nosing strip with a slip-resistance classification not less than that listed in Table D3D15 when tested in accordance with AS 4586; and\ntreads of solid construction (not mesh or other perforated material) if the stairway is more than 10 m high or connects more than 3 storeys; and\nin a Class 9b building, not more than 36 risers in consecutive flights without a change in direction of at least 30°; and\nin the case of a required stairway, no winders in lieu of a landing; and\nconspicuous edges to the treads of steps in a Class 9b building used as an entertainment venue; and\nin a Class 9b building used as an entertainment venue, not more than one helical stairway serving as a required exit and that stairway must—\nhave a width of not less than 1500 mm; and\nbe of constant radius; and\nbe constructed so that each tread, when measured 500 mm in from its narrow end, has a width of at least 280 mm; and\nin a Class 9b building used as an entertainment venue, in a curved stairway serving as a required exit — an internal radius of not less than twice the width of the stair.","st":"NSW","base":"D3D14","g":"/ncc/nsw-d3d14"},{"c":"NSW D3D16","t":"Thresholds","p":"NSW Part D3 Construction of exits","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-d3-construction-exits#_b6268150-dda1-4506-88fe-a4738f43fb2c","x":"Delete clause D3D16 and insert NSW D3D16 as follows:\nThe threshold of a doorway must not incorporate a step or ramp at any point closer to the doorway than the width of the door leaf unless the doorway opens to an external space; and—\nwhere the doorway serves an area required to be accessible by Part D4, it is provided with a threshold ramp or step ramp in accordance with AS 1428.1; or\nwhere (a) does not apply—\nin a Class 9b building used as an entertainment venue, the door sill is not more than 50 mm above the finished surface of the ground, balcony, or the like to which the door opens; or\nexcept as provided by (i), the door sill is not located below, and is not more than 190 mm above the finished surface of the ground, balcony, or the like to which the doorway opens.\nExemptions\nNSW D3D16 does not apply to a plant room, machinery room, or the like.","st":"NSW","base":"D3D16","g":"/ncc/nsw-d3d16"},{"c":"NSW D3D18","t":"Height of barriers","p":"NSW Part D3 Construction of exits","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-d3-construction-exits#_00260770-0799-454d-b7b4-b1fc1e604b7e","x":"Delete subclause D3D18(1) and insert NSW D3D18(1) as follows:\n(1) The height of a barrier required by D3D17 must be not less than the following:\nFor stairways or ramps with a gradient of 1:20 or steeper — 865 mm.\nFor landings to a stair or ramp where the barrier is provided along the inside edge of the landing and does not exceed 500 mm in length — 865 mm.\nIn front of fixed seating on a mezzanine or balcony within an auditorium in a Class 9b building—\n1 m; or\n700 mm where the horizontal projection extends not less than 1 m outwards from the top of the barrier; or\nin a Class 9b building used as an entertainment venue, the height prescribed for guardrails in NSW I4D41 or NSW I5D9.\nIn a Class 9b building used as an entertainment venue, for stairways and ramps and the floor of any access path, balcony, landing or the like—\n1 m when provided inside the building; and\n1200 mm when provided externally to the building.\nFor all other locations — 1 m.","st":"NSW","base":"D3D18","g":"/ncc/nsw-d3d18"},{"c":"NSW D3D24","t":"Doorways and doors","p":"NSW Part D3 Construction of exits","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-d3-construction-exits#_b34cd05b-57e3-443c-9137-566893b8c105","x":"Delete subclause D3D24(2) and insert NSW D3D24(2) as follows:\n(2) A doorway serving as a required exit or forming part of a required exit, or a doorway in a patient care area of a Class 9a health-care building —\nmust not be fitted with a revolving door; and\nmust not be fitted with a roller shutter or tilt-up door unless—\nit serves a Class 6, 7 or 8 building or part with a floor area not more than 200 m2; and\nthe doorway is the only required exit from the building or part; and\nit is held in the open position while the building or part is lawfully occupied; and\nmust not be fitted with a sliding door unless—\nit leads directly to a road or open space; and\nthe door is able to be opened manually under a force of not more than 110 N; and\nif fitted with a door which is power-operated—\nit must be able to be opened manually under a force of not more than 110 N if there is a malfunction or failure of the power source; and\nif it leads directly to a road or open space it must open automatically if there is a power failure to the door or on the activation of a fire or smoke alarm anywhere in the fire compartment served by the door; and\nin a Class 9b building used as an entertainment venue —\nmust not be fitted with a collapsible gate, accordion door, turnstile or rigid barrier; and\nif fitted with a door, must be—\na swing door which opens in the direction of egress; and\ndoors hung in two folds where the unobstructed width of the doorway is more than 1 m; and\na doorway or opening within sight of the audience but not intended for egress must have a notice displayed clearly indicating its purpose and such a notice must not be internally illuminated; and\nnotwithstanding (2)(c), a sliding door may be fitted where—\nit leads directly to a road or open space and forms a main entrance; and\nit is capable of swinging in the direction of egress when pressure is applied to the inside face of the door; and\nthe door is provided with signage that clearly indicates to persons seeking egress, the potential for swinging the door open in an emergency.","st":"NSW","base":"D3D24","g":"/ncc/nsw-d3d24"},{"c":"NSW D3D26","t":"Operation of latch","p":"NSW Part D3 Construction of exits","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-d3-construction-exits#_2d25e9d6-bc98-4b44-bc4b-94f4fff4d05d","x":"Delete subclause D3D26(5) and insert NSW D3D26(5) as follows:\n(5) The requirements of (1) and (2) do not apply in a Class 9b building (other than a school, an early childhood centre or a building used for religious purposes) to a door in a required exit, forming part of a required exit or in the path of travel to a required exit serving a storey or room accommodating more than 100 persons, determined in accordance with D2D18, in which case it must be readily openable—\nwithout a key from the side that faces a person seeking egress; and\nby a single hand pushing action on a single device such as a panic bar located between 900 mm and 1.2 m from the floor; and\nwhere a two-leaf door is fitted, the provisions of (a) and (b) need only apply to one door leaf if the appropriate requirements of D2D9 are satisfied by the opening of that one leaf; and\nwhere the door is a door in a path of travel providing re-entry to the building from a balcony, terrace or the like, it may be fitted with key-operated fastenings only, the tongues of which must be locked in the retracted position whenever the building is occupied by the public, so the door can yield to pressure.\nInsert NSW subclause D3D26(6) in clause D3D26 as follows:\n(6) The requirements of (1), (2) and (5) do not apply to a door serving a Class 9b building used as an entertainment venue where the following provisions apply to a door or gate used by the public—\non a door, the single device operating the latch or bolts must be a panic bar if those doors are to be secured; or\nan exit door or gate used by the public as the main entrance may be fitted with key-operated fastenings only, the tongues of which must be locked in the retracted position whenever the building is occupied by the public so the door or gate can yield to pressure from within; or\na door from a balcony, terrace or the like, being a door in a path of travel providing re-entry to the building, may comply with the locking provision of (b) above.","st":"NSW","base":"D3D26","g":"/ncc/nsw-d3d26"},{"c":"NSW D3D32","t":"Doors in paths of travel to an entertainment venue","p":"NSW Part D3 Construction of exits","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-d3-construction-exits#_78cdfd5a-5b89-4050-818c-b97d38aca3bb","x":"Insert NSW clause D3D32 in clause D3D32 as follows:\nIn a Class 9b building used as an entertainment venue, a doorway in a path of travel must comply with NSW D3D24(2)(e).","st":"NSW","base":"D3D32","g":"/ncc/nsw-d3d32"},{"c":"NSW D4D1","t":"Deemed-to-Satisfy Provisions","p":"NSW Part D4 Access for people with a disability","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-d4-access-people-disability#_118bfe65-2235-43cc-820a-39e3abeecfb6","x":"Delete subclause D4D1(1) and insert NSW D4D1(1) as follows:\n(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements D1P1 to D1P6 and D1P8 to D1P10 are satisfied by complying with—\nD2D2 to D2D23, D3D2 to NSW D3D32 and D4D2 to D4D13; and\nin a building containing an atrium, Part G3; and\nin a building in an alpine area, Part G4; and\nfor additional requirements for Class 9b buildings, Part I1; and\nfor public transport buildings, Part I2.","st":"NSW","base":"D4D1","g":"/ncc/nsw-d4d1"},{"c":"NSW E2D1","t":"Deemed-to-Satisfy Provisions","p":"NSW Part E2 Smoke hazard management","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-e2-smoke-hazard-management#_b217b410-55b9-4b82-af47-11ab7d0335a0","x":"Delete subclause E2D1(1) and insert NSW E2D1(1) as follows:\n(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements E2P1 and E2P2 are satisfied by complying with—\nE2D2 to NSW E2D21; and\nin a building containing an atrium, Part G3; and\nin a building in an alpine area, Part G4; and\nfor additional requirements for Class 9b buildings, Part I1.","st":"NSW","base":"E2D1","g":"/ncc/nsw-e2d1"},{"c":"NSW E2D2","t":"Application of part","p":"NSW Part E2 Smoke hazard management","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-e2-smoke-hazard-management#_cd80dd06-f1b1-4090-9ddb-ee16bbd3f13d","x":"Delete subclause E2D2(2) and insert NSW E2D2(2) as follows:\n(2) In addition to the Deemed-to-Satisfy Provisions of E2D3 to E2D13, the following specific Deemed-to-Satisfy Provisions apply to the following Class 6 and Class 9b buildings:\nFor Class 6 buildings, in fire compartments more than 2000 m2—\nnot containing an enclosed common walkway or mall serving more than one Class 6 sole-occupancy unit — must comply with E2D14; or\ncontaining an enclosed common walkway or mall serving more than one Class 6 sole-occupancy unit — must comply with E2D15.\nFor Class 9b assembly buildings —\nall assembly buildings — must comply with NSW E2D16; and\nnightclubs, discotheques and the like — must comply with NSW E2D17; and\nexhibition halls, museums and art galleries — must comply with NSW E2D18; and\nother assembly buildings (not listed in (i) to (iii)) — must comply with NSW E2D19.","st":"NSW","base":"E2D2","g":"/ncc/nsw-e2d2"},{"c":"NSW E2D10","t":"Buildings not more than 25 m in effective height: large isolated buildings subject to C3D4","p":"NSW Part E2 Smoke hazard management","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-e2-smoke-hazard-management#_27a1f5a3-7565-4c04-a2b4-bae19da002e9","x":"Delete clause E2D10 and insert NSW E2D10 as follows:\n(1) In a Class 5, 6, 7, 8 or 9 building of not more than 25 m in effective height, and which exceeds 18 000 m2 in floor area or 108 000 m3 in volume, the building must be provided with—\nif the ceiling height of the fire compartment is not more than 12 m—\nan automatic smoke exhaust system in accordance with Specification 21; or\nautomatic smoke-and-heat vents in accordance with Specification 22; or\nif the ceiling height of the fire compartment is more than 12 m, an automatic smoke exhaust system in accordance with Specification 21.\n(2) For the purposes of (1), reference to ‘the building’ being provided with specified measures, means to the nominated classes within the building.\nNotes\nRefer to E2D14 and E2D15 for specific provisions applicable to a Class 6 building or part of a building (in a fire compartment having a floor area of more than 2000 m2).\nRefer to NSW E2D16 to NSW E2D19 for specific provisions applicable to a Class 9b building or part of a building.\nRefer to E2D5 and E2D8 where a Class 5, 6, 7b, 8 and 9b building contains a Class 2, 3 or 4 part.","st":"NSW","base":"E2D10","g":"/ncc/nsw-e2d10"},{"c":"NSW E2D16","t":"Class 9b – assembly buildings: all","p":"NSW Part E2 Smoke hazard management","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-e2-smoke-hazard-management#_8f7e230e-b4d4-4b3b-a325-123311821d12","x":"Delete clause E2D16 and insert NSW E2D16 as follows:\nThe following provisions apply to all Class 9b assembly buildings:\nA building or part of a building used as an assembly building must be provided with automatic shutdown of any air-handling system (other than non-ducted individual room units with a capacity not more than 1000 L/s and ventilation systems installed in accordance with Sections 5 and 6 of AS 1668.1) which does not form part of the smoke hazard management system, on the activation of—\nsmoke detectors installed complying with S20C6; and\nany other installed fire detection and alarm system, including a sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17.\nA basement not counted in the rise in storeys in accordance with C2D3, less than 2000 m2 used as an assembly building or part of an assembly building containing an auditorium or other public area, must be equipped with—\nan automatic smoke detection system in accordance with Specification 20; or\nan automatic zone pressurisation system in accordance with AS 1668.1 if the basement has more than one fire compartment; or if the basement forms part of a multi fire compartmented building served by the zone pressurisation system; or\na sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17.\nStages and backstages:\nFor the purposes of this clause, where a stage is separated from the auditorium by a proscenium wall incorporating a proscenium opening, a backstage room or area that is not separated from the stage by construction having an FRL of not less than 60/60/60, is taken to form part of the stage.\nA building or part of a building used as an assembly building which has a stage with a floor area of more than 50 m2 and not more than 150 m2 must, over the stage, be provided with—\nan automatic smoke exhaust system complying with Specification 21 (including Figure S21C2); or\nroof mounted automatic smoke-and-heat vents complying with NSW I4D59, in a single storey building or the top storey of a multi storey building.\nA building or part of a building used as an assembly building which has a stage with a floor area of more than 150 m2 must, over the stage, be provided with an automatic smoke exhaust system complying with Specification 21 (including Figure S21C2).\nA building or part of a building used as an assembly building which has a stage equipped with means of flying scenery must, over the stage, be provided with an automatic smoke exhaust system complying with Specification 21 (including Figure S21C2).","st":"NSW","base":"E2D16","g":"/ncc/nsw-e2d16"},{"c":"NSW E2D17","t":"Class 9b – assembly buildings: night clubs, discotheques and the like","p":"NSW Part E2 Smoke hazard management","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-e2-smoke-hazard-management#_17946838-0ca2-4752-b134-b270a8d0faf8","x":"Delete clause E2D17 and insert NSW E2D17 as follows:\nA building or part of a building being a night club, discotheque or the like, must be provided with—\nin an auditorium—\nan automatic smoke exhaust system complying with Specification 21; or\nroof mounted automatic smoke-and-heat vents complying with Specification 22, in a single storey building or the top storey of a multi storey building; or\na sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17 with fast response sprinkler heads; and\nin all other areas—\nwhere a building or part of a building has a floor area not more than 2000 m2—\none of the smoke hazard management measures listed under (a) above; or\nan automatic smoke detection and alarm system complying with Specification 20; or\nwhere a building or part of a building has a floor area of more than 2000 m2, smoke hazard management measures as provided for under NSW E2D19.\nNotes\nParagraph (a) applies only to an auditorium designed principally to accommodate an audience to an entertainment.\nSmoke hazard management provisions for an assembly building used for multiple purposes must comply with all the relevant provisions of NSW E2D16, NSW E2D17, NSW E2D18 and NSW E2D19 according to usage.","st":"NSW","base":"E2D17","g":"/ncc/nsw-e2d17"},{"c":"NSW E2D18","t":"Class 9b – assembly buildings: exhibition halls, museums and art galleries","p":"NSW Part E2 Smoke hazard management","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-e2-smoke-hazard-management#_9e6990c1-4e7d-476e-a05f-d0d412017021","x":"Delete clause E2D18 and insert NSW E2D18 as follows:\nA building or part of a building used as an exhibition hall, museum, art gallery or the like, must be provided with—\nwhere the floor area is more than 2000 m2 and not more than 3500 m2—\nan automatic smoke exhaust system complying with Specification 21; or\nroof mounted automatic smoke-and-heat vents complying with Specification 22 in a single storey building or the top storey of a multi storey building; or\na sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17; and\nwhere the floor area is more than 3500 m2, a sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17 and—\nan automatic smoke exhaust system complying with Specification 21; or\nroof mounted automatic smoke-and-heat vents complying with Specification 22 , in a single storey building or the top storey of a multi storey building.\nNotes\nSmoke hazard management provisions for an assembly building used for multiple purposes must comply with all the relevant provisions of NSW E2D16, NSW E2D17, NSW E2D18 and NSW E2D19 according to usage.","st":"NSW","base":"E2D18","g":"/ncc/nsw-e2d18"},{"c":"NSW E2D19","t":"Class 9b – assembly buildings: other assembly buildings (not listed in NSW E2D16 to E2D18)","p":"NSW Part E2 Smoke hazard management","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-e2-smoke-hazard-management#_5d43d77a-2d24-46be-b6a3-f65e2e543dae","x":"Delete clause E2D19 and insert NSW E2D19 as follows:\n(1) Unless otherwise described in (2), in a building or part of a building used as an assembly building (not being a night club, discotheque or the like; or an exhibition hall, museum or art gallery) where the floor area of the Class 9b part of a fire compartment is more than 2000 m2, the Class 9b building or part must be provided with—\nan automatic smoke exhaust system complying with Specification 21; or\nroof mounted automatic smoke-and-heat vents complying with Specification 22, in a single storey building or the top storey of a multi storey building; or\nif the floor area of the fire compartment is not more than 5000 m2 and the building has a rise in storeys of not more than 2—\nan automatic smoke detection and alarm system complying with Specification 20; or\na sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17.\n(2) The following buildings are exempt from the provisions of (1):\nSporting complexes, (including sports halls, gymnasiums, swimming pools, ice and roller rinks, and the like) other than indoor sports stadiums with total spectator seating for more than 1000 persons.\nChurches and other places used solely for religious worship.\nSchool classrooms.\n(3) A building containing a Class 9b early childhood centre must be provided with an automatic smoke detection and alarm system complying with Specification 20 throughout the whole building, including any part of another Class.\nNotes\nSmoke hazard management provisions for an assembly building used for multiple purposes must comply with all the relevant provisions of NSW E2D16, NSW E2D17, NSW E2D18 and NSW E2D19 according to usage.","st":"NSW","base":"E2D19","g":"/ncc/nsw-e2d19"},{"c":"NSW E2D20","t":"Class 9b assembly buildings: other assembly buildings (not listed in E2D16 to E2D19)","p":"NSW Part E2 Smoke hazard management","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-e2-smoke-hazard-management#_id10909","x":"This clause has deliberately been left blank.\nE2D20 does not apply in NSW. This clause is deleted from the BCA in NSW, as requirements for Class 9b – Assembly buildings in NSW are covered under NSW E2D16 to NSW E2D19.","st":"NSW","base":"E2D20","g":"/ncc/nsw-e2d20"},{"c":"NSW E2D21","t":"Provision for special hazards","p":"NSW Part E2 Smoke hazard management","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-e2-smoke-hazard-management#_2ff65d55-a2ba-4921-bda1-2fbefcb647a0","x":"Delete clause E2D21 and insert NSW E2D21 as follows:\nAdditional smoke hazard management measures may be necessary due to the—\nspecial characteristics of the building; or\nspecial function or use of the building; or\nspecial type or quantity of materials stored, displayed or used in a building; or\nspecial mix of classifications within a building or fire compartment,\nwhich are not addressed in E2D4 to NSW E2D19.","st":"NSW","base":"E2D21","g":"/ncc/nsw-e2d21"},{"c":"NSW E4D6","t":"Direction signs","p":"NSW Part E4 Visibility in an emergency, exit signs and warning systems","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-e4-visibility-emergency-exit-signs-and-warning-systems#_713f6af9-75de-47d2-b9cb-d244b56cd903","x":"Delete clause E4D6 and insert NSW E4D6 as follows:\nIf an exit is not readily apparent to persons occupying or visiting the building, then exit signs must be installed—\nin appropriate positions in corridors, hallways, lobbies, foyers, auditoria, and the like, indicating the direction to a required exit; and\nin a Class 9b building used as an entertainment venue — in any external egress path to a road where the exit does not open directly onto a road.","st":"NSW","base":"E4D6","g":"/ncc/nsw-e4d6"},{"c":"NSW F4P6","t":"Microbial control for water systems","p":"NSW Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-f4-sanitary-and-other-facilities#_id12801","x":"This clause has deliberately been left blank.\nF4P6 does not apply in NSW as the installation of hot water, warm water and cooling water systems (and their operation and maintenance) is regulated in the Public Health Regulation 2022, under the Public Health Act 2010.","st":"NSW","base":"F4P6","g":"/ncc/nsw-f4p6"},{"c":"NSW F4D10","t":"Microbial (legionella) control","p":"NSW Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-f4-sanitary-and-other-facilities#_id13176","x":"This clause has deliberately been left blank.\nF4D10 does not apply in NSW as the installation of hot water, warm water and cooling water systems (and their operation and maintenance) is regulated in the Public Health Regulation 2022, under the Public Health Act 2010.","st":"NSW","base":"F4D10","g":"/ncc/nsw-f4d10"},{"c":"NSW F6D6","t":"Ventilation of rooms","p":"NSW Part F6 Light and ventilation","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-f6-light-and-ventilation#_02d71a14-20f1-4b38-9fa5-e8be3c29587e","x":"Delete clause F6D6 and insert NSW F6D6 as follows:\nA habitable room, office, shop, factory, workroom, sanitary compartment, bathroom, shower room, laundry and any other room or space occupied by a person for any purpose must have—\nnatural ventilation complying with—\nF6D7; or\nAS 1668.4; or\na mechanical ventilation or air-conditioning system complying with AS 1668.2.\nNotes\nThe reference to AS/NZS 3666.1 is deleted from the BCA in NSW, as the need to comply with this standard is regulated in the Public Health Regulation 2022, under the Public Health Act 2010.","st":"NSW","base":"F6D6","g":"/ncc/nsw-f6d6"},{"c":"NSW Part F8","t":"Condensation management","p":"NSW Part F8 Condensation management","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-f8-condensation-management","x":"This Part has been deliberately left blank. Part F8 of NCC 2025 Volume One does not apply in NSW and Part F8 of NCC 2022 Amendment 2 Volume One applies in NSW.","st":"NSW","base":"Part F8","g":"/ncc/nsw-part-f8"},{"c":"NSW G1O1","t":"Objective","p":"NSW Part G1 Minor structures and components","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-g1-minor-structures-and-components#_648e1a47-6848-4e66-a956-89e79ceea1a8","x":"Delete clause G1O1 and insert NSW G1O1 as follows:\nThe Objective of this Part is to—\nsafeguard people from illness caused by the discharge of swimming pool waste water; and\nprotect other property from damage caused by the discharge of swimming pool waste water; and\nsafeguard young children from drowning or injury in a swimming pool; and\nsafeguard people from drowning or injury due to suction by a swimming pool water recirculation system; and\nsafeguard occupants from illness or injury resulting from being accidentally locked inside spaces which are designed to be entered for short periods of time only and in which occupation for longer periods may be hazardous; and\nsafeguard young children in outdoor play spaces; and\nsafeguard people from falls and injury caused when cleaning windows.\nApplications\nNSW G1O1(d) only applies to a swimming pool with a depth of water more than 300 mm.\nNSW G1O1(f) only applies to a Class 9b early childhood centre.\nNSW G1O1(g) only applies where any windows are located 3 or more storeys above ground level.","st":"NSW","base":"G1O1","g":"/ncc/nsw-g1o1"},{"c":"NSW G1F5","t":"Cleaning of windows","p":"NSW Part G1 Minor structures and components","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-g1-minor-structures-and-components#_0f1dcea2-0a18-4bcb-b9b6-fb7ef09443c7","x":"Insert NSW clause G1F5 in clause G1F5 as follows:\nA building is to be provided with a means to allow for the safe cleaning of windows.\nApplications\nNSW G1F5 only applies where any windows are located 3 or more storeys above ground level.","st":"NSW","base":"G1F5","g":"/ncc/nsw-g1f5"},{"c":"NSW G1P2","t":"Swimming pool access and water recirculation systems","p":"NSW Part G1 Minor structures and components","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-g1-minor-structures-and-components#_311f1af0-8899-4d28-8c9a-77aaa5ecc86c","x":"Delete clause G1P2 and insert NSW G1P2 as follows:\n(1) A barrier must be provided to a swimming pool and must—\nbe continuous for the full extent of the hazard; and\nbe of a strength and rigidity to withstand the foreseeable impact of people; and\nrestrict the access of young children to the pool and the immediate pool surrounds; and\nhave any gates and doors fitted with latching devices not readily operated by young children, and constructed to automatically close and latch.\n(2) A swimming pool water recirculation system must incorporate safety measures to avoid entrapment of, or injury to, a person.\nApplications\nNSW G1P2(1) only applies to a swimming pool with a depth of water more than 300 mm, in conjunction with the Swimming Pools Act 1992 and the Swimming Pools Regulation 2018.\nNSW G1P2(2) only applies to a swimming pool with a depth of water more than 300 mm.","st":"NSW","base":"G1P2","g":"/ncc/nsw-g1p2"},{"c":"NSW G1P6","t":"Cleaning of windows","p":"NSW Part G1 Minor structures and components","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-g1-minor-structures-and-components#_37a91cb7-cf05-4284-bc76-9528db59a914","x":"Insert NSW clause G1P6 in clause G1P6 as follows:\nA building must provide for a safe manner for the cleaning of windows.\nApplications\nNSW G1P6 only applies where any windows are located 3 or more storeys above ground level.","st":"NSW","base":"G1P6","g":"/ncc/nsw-g1p6"},{"c":"NSW G1D1","t":"Deemed-to-Satisfy Provisions","p":"NSW Part G1 Minor structures and components","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-g1-minor-structures-and-components#_0552bd82-b4c8-4758-aa1f-e913f82f4031","x":"Delete subclause G1D1(1) and insert NSW G1D1(1) as follows:\n(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements G1P1 to NSW G1P6 are satisfied by complying with NSW G1D2 to NSW G1D6.","st":"NSW","base":"G1D1","g":"/ncc/nsw-g1d1"},{"c":"NSW G1D2","t":"Swimming pools","p":"NSW Part G1 Minor structures and components","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-g1-minor-structures-and-components#_a05d0c1e-c43c-43d5-aa51-76c2ef832f80","x":"Delete clause G1D2 and insert NSW G1D2 as follows:\n(1) NSW G1D2(2) applies to the technical construction requirements for barriers to restrict access to swimming pools, subject to—\nout-of-ground pool walls and the walls of above ground pools, including inflatable pools, not being considered to be effective barriers; and\nthe reference in clause 2.3.1 of AS 1926.1 to ‘This clause shall not apply to boundary barriers.’ is replaced with ‘This clause shall apply to boundary barriers.’.\n(2) A swimming pool with a depth of water more than 300 mm and which is associated with a Class 2 or 3 building or Class 4 part of a building, must have suitable barriers to restrict access by young children to the immediate pool surrounds in accordance with—\nAS 1926.1 and AS 1926.2; or\nif the swimming pool is a spa pool —\nthe requirements of (a); or\nclause 9 of the Swimming Pools Regulation 2018.\n(3) A water recirculation system in a swimming pool with a depth of water more than 300 mm must comply with AS 1926.3.\nNotes\nThe Swimming Pools Act 1992 and the Swimming Pools Regulation 2018, applicable to swimming pool with a depth of water of more than 300 mm, regulate the circumstances in which a barrier is required and prevail in the case of any inconsistency.","st":"NSW","base":"G1D2","g":"/ncc/nsw-g1d2"},{"c":"NSW G1D6","t":"Cleaning windows","p":"NSW Part G1 Minor structures and components","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-g1-minor-structures-and-components#_406689b7-8754-4414-b629-aede0da02753","x":"Insert NSW clause G1D6 in clause G1D6 as follows:\nA building that includes windows located 3 or more storeys above ground level satisfies Performance Requirement NSW G1P6 where—\nthe windows can be cleaned wholly from within the building; or\nprovision is made for the cleaning of the windows by a method complying with the Work Health and Safety Act 2011 and Regulations made under that Act.","st":"NSW","base":"G1D6","g":"/ncc/nsw-g1d6"},{"c":"NSW G5O1","t":"Objective","p":"NSW Part G5 Construction in bushfire prone areas","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-g5-construction-bushfire-prone-areas#_5c464072-1ae9-42e2-ab3d-8091e14dd0ee","x":"Delete clause G5O1 and insert NSW G5O1 as follows:\nThe Objective of this Part is to—\nsafeguard occupants from injury from the effects of a bushfire; and\nprotect buildings from the effects of a bushfire; and\nfacilitate temporary shelter for building occupants who may be unable to readily evacuate the building prior to a bushfire.\nApplications\nNSW G5O1(a) and (b) apply in a designated bushfire prone area to—\na Class 2 or 3 building; or\na Class 4 part of a building; or\na Class 10a building or deck associated with a Class 2 or 3 building, or a Class 4 part of a building.\nNSW G5O1(a), (b) and (c) apply in a designated bushfire prone area to—\na Class 9 building that is a special fire protection purpose; and\na Class 10a building or deck immediately adjacent or connected to a building of a type listed in (a).","st":"NSW","base":"G5O1","g":"/ncc/nsw-g5o1"},{"c":"NSW G5F1","t":"Construction in bushfire prone areas","p":"NSW Part G5 Construction in bushfire prone areas","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-g5-construction-bushfire-prone-areas#_05612e55-a8ef-42c1-b46b-e160e853a4c5","x":"Delete clause G5F1 and insert NSW G5F1 as follows:\nA building constructed in a designated bushfire prone area —\nis to provide a resistance to bushfires in order to reduce the danger to life and minimise the risk of the loss of the building; and\nif occupied by people who may be unable to readily evacuate the building prior to a bushfire, is to be constructed so as to provide its occupants shelter from the direct and indirect actions of a bushfire.\nApplications\nNSW G5F1(a) applies in a designated bushfire prone area to—\na Class 2 or 3 building; or\na Class 4 part of a building; or\na Class 10a building or deck associated with a Class 2 or 3 building, or a Class 4 part of a building; or\na Class 10a building or deck immediately adjacent or connected to a building of a type listed in (2).\nNSW G5F1(a) and (b) apply in a designated bushfire prone area to a Class 9 building that is a special fire protection purpose.","st":"NSW","base":"G5F1","g":"/ncc/nsw-g5f1"},{"c":"NSW G5P1","t":"Bushfire resistance","p":"NSW Part G5 Construction in bushfire prone areas","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-g5-construction-bushfire-prone-areas#_0aa1f97f-07ac-4c21-a720-30148c8b31bb","x":"Delete clause G5P1 and insert NSW G5P1 as follows:\nExcept as amended by Planning for Bush Fire Protection, a building that is constructed in a designated bushfire prone area must be designed and constructed to—\nreduce the risk of ignition from a design bushfire with an annual exceedance probability not more than 1:100 years, or 1:200 years for a Class 9 building; and\ntake account of the assessed duration and intensity of the fire actions of the design bushfire; and\nprevent internal ignition of the building and its contents; and\nmaintain the structural integrity of the building for the duration of the design bushfire.\nApplications\nNSW G5P1 only applies in a designated bushfire prone area to—\na Class 2 or 3 building; or\na Class 4 part of a building; or\na Class 9 building that is a special fire protection purpose; or\na Class 10a building or deck immediately adjacent or connected to a building or part of a type listed in (a), (b) or (c).","st":"NSW","base":"G5P1","g":"/ncc/nsw-g5p1"},{"c":"NSW G5P2","t":"Additional bushfire requirements for Class 9 buildings that are a special fire protection purpose","p":"NSW Part G5 Construction in bushfire prone areas","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-g5-construction-bushfire-prone-areas#_929a5c88-6590-4c60-a1fd-f2d64ec6d039","x":"Delete clause G5P2 and insert NSW G5P2 as follows:\nExcept as amended by Planning for Bush Fire Protection, a building that is constructed in a designated bushfire prone area and occupied by people who may be unable to readily evacuate the building prior to a bushfire must, to the degree necessary—\nreduce the risk of an untenable indoor environment for occupants during a bushfire event, appropriate to the—\nlocation of the building relative to fire hazards, including—\nclassified vegetation; and\nadjacent buildings, structures and movable objects; and\ncarparking areas and allotment boundaries; and\nother combustible materials; and\nnumber of occupants to be accommodated within the building; and\nintensity of bushfire attack on the building; and\nduration of occupancy; and\nintensity of potential consequential fires; and\noccupant tenability within the building before, during and after the bushfire event; and\ncombined effects of structural, fire exposure and other effects to which the building may reasonably be subjected; and\nprovision of fire fighting equipment and water supply to facilitate protection of the building; and\nbe provided with vehicular access to the site to enable firefighting and emergency personnel to defend or evacuate the building; and\nhave access to a sufficient supply of water for firefighting purposes on the site; and\nprovide safe access within the site to the building (including carparking areas), as well as safe egress after the bushfire event.\nApplications\nNSW G5P2 applies to a Class 9 building that is a special fire protection purpose located in a designated bushfire prone area.\nNotes\nNSW G5P2 does not guarantee the safety of building occupants or the maintenance of tenable conditions within a building during a bushfire event.","st":"NSW","base":"G5P2","g":"/ncc/nsw-g5p2"},{"c":"NSW G5V1","t":"Buildings in bushfire prone areas","p":"NSW Part G5 Construction in bushfire prone areas","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-g5-construction-bushfire-prone-areas#_8535722b-e55f-4e99-91e3-dd3a8e11021b","x":"Delete clause G5V1 and insert NSW G5V1 as follows:\n(1) Compliance with Performance Requirement G5P1 is verified if the ignition probability for a building exposed to a design bushfire does not exceed 10%.\n(2) Bushfire design actions must be determined in consideration of the annual probability of a design bushfire derived from—\nassigning the building or structure with an Importance Level in accordance with (3); and\ndetermining the corresponding annual probability of exceedance in accordance with Table G5V1.\n(3) A building or structure's Importance Level must be identified as one of the following:\nImportance Level 1 — where the building or structure presents a low degree of hazard to life and other property in the case of failure.\nImportance Level 2 — where the building or structure is not of Importance Level 1, 3 or 4 or is a Class 2 building accommodating 12 people or less.\nImportance Level 3 — where the building is designed to contain a large number of people and is a—\nClass 2 building accommodating more than 12 people; or\nClass 3 boarding house, guest house, hostel, lodging house or backpackers accommodation; or\nClass 3 residential part of a hotel or motel; or\nClass 3 residential part of a school.\nImportance Level 4 — where the building or structure is—\nessential to emergency management or post-disaster recovery; or\nassociated with hazardous facilities; or\nsubject to a necessary ‘defend in place’ strategy and is a—\nClass 3 accommodation building for the aged, children or people with disabilities; or\nClass 3 residential part of a health-care building which accommodates members of staff; or\nClass 3 residential part of a detention centre; or\nbuilding that operates in the event of a bushfire emergency, such as a public bushfire shelter or a bushfire emergency control centre.\n(4) The ignition probability for a building must be assessed by application of the following:\nAn event tree analysis of relevant bushfire scenarios.\nDesign bushfire conditions that include combinations of the following actions appropriate to the distance between the building and the bushfire hazard:\nDirect attack from airborne burning embers.\nBurning debris and accumulated embers adjacent to a building element.\nRadiant heat from a bushfire front.\nDirect flame attack from a bushfire front.\n(5) Applied fire actions must allow for reasonable variations in—\nfire weather; and\nvegetation, including fuel load, burning behaviour of vegetation (including the potential for crown fires); and\nthe distance of the building from vegetation; and\ntopography, including slopes and features that may shield; and\nignition of adjacent buildings, building elements, plants, mulch and other materials; and\neffective size of fire front; and\nduration of exposure; and\nflame height; and\nflame tilt; and\nflame adhesion to sloping land; and\nthe height of the building and its elements.\n(6) The assessment process must include consideration of—\nthe probability of non-complying construction of critical aspects of an approved design; and\nthe probability of critical aspects of an approved design being fully functional during the life of the building; and\ninclusion of safety factors; and\nsensitivity analysis of critical aspects of a proposed design.\nLimitations\nNSW G5V1 does not apply to a Class 9 building that is a special fire protection purpose.\nNotes\nFor a building that is subject to NSW G5P2, and therefore outside the scope of NSW G5V1, the building would need to comply with either—\nPerformance Requirement NSW G5P2 by means of a Performance Solution; or\nthe Deemed-to-Satisfy Provisions of NSW G5D4, where a building satisfies the requirements of NSW G5D2(c).\nTable G5V1 Annual Probability of Exceedance (APE) for design bushfire actions\nImportance Level\nComplex analysis APE for bushfire exposure\nSimple analysis APE for weather conditions (design bushfire)\n1\nNo requirement\nNo requirement\n2\n1:500\n1:50\n3\n1:1000\n1:100\n4\n1:2000\n1:200\nTable Notes\nComplex analysis must consider the probability of ignition, fire spread to the urban interface and penetration of the urban interface coincident with fire weather conditions.","st":"NSW","base":"G5V1","g":"/ncc/nsw-g5v1"},{"c":"NSW G5D1","t":"Deemed-to-Satisfy Provisions","p":"NSW Part G5 Construction in bushfire prone areas","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-g5-construction-bushfire-prone-areas#_8ea31590-d81b-4047-83de-6d239df61820","x":"Delete subclause G5D1(1) and insert NSW G5D1(1) as follows:\n(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements NSW G5P1 and subject to NSW G5D2, NSW G5P2, are satisfied by complying with NSW G5D3 and NSW G5D4.","st":"NSW","base":"G5D1","g":"/ncc/nsw-g5d1"},{"c":"NSW G5D2","t":"Application of Part","p":"NSW Part G5 Construction in bushfire prone areas","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-g5-construction-bushfire-prone-areas#_27bcc3eb-1bdf-4937-ae68-6a7763a3570a","x":"Delete clause G5D2 and insert NSW G5D2 as follows:\nThe Deemed-to-Satisfy Provisions of this Part apply in a designated bushfire prone area to—\na Class 2 or 3 building; or\na Class 4 part of a building; or\na Class 9 building that is a special fire protection purpose —\nlocated in an area subject to radiant heat levels of not greater than 10kW/m2 (calculated at 1200k), determined in accordance with Planning for Bush Fire Protection; or\nwhere the development consent or a bushfire safety authority issued under Section 100B of the Rural Fires Act 1997 states that the Deemed-to-Satisfy Provisions apply; or\na Class 10a building or deck immediately adjacent or connected to a building or part of a type in (a), (b) or (c).\nNotes\nIf a building of a type listed in (c) or (d) where associated with a building listed in (c) is subject to a radiant heat levels of greater than 10kW/m2 (calculated at 1200K), the building would need to comply with Performance Requirement NSW G5P2 by means of a Performance Solution. Unless the development consent or a bushfire safety authority issued under section 100B of the Rural Fires Act 1997 has stated that the Deemed-to-Satisfy Provisions of this part can apply.\nOther than the circumstances listed in (1) there are no Deemed-to-Satisfy Provisions for buildings of the types listed in (c) or (d) where associated with a building listed in (c).","st":"NSW","base":"G5D2","g":"/ncc/nsw-g5d2"},{"c":"NSW G5D3","t":"Protection","p":"NSW Part G5 Construction in bushfire prone areas","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-g5-construction-bushfire-prone-areas#_1784da48-a349-4ff3-b418-5eabee39ce49","x":"Delete clause G5D3 and insert NSW G5D3 as follows:\nIn a designated bushfire prone area, a Class 2 building, a Class 3 building, a Class 4 part of a building or a Class 10a building or deck immediately adjacent or connected to such a building or part, must comply with the following—\nAS 3959 except as amended by Planning for Bush Fire Protection; or—\nthe requirements of (a) above as modified by the development consent or a bushfire safety authority issued under section 100B of the Rural Fires Act 1997.","st":"NSW","base":"G5D3","g":"/ncc/nsw-g5d3"},{"c":"NSW G5D4","t":"Protection – Class 9 buildings used as a special fire protection purpose","p":"NSW Part G5 Construction in bushfire prone areas","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-g5-construction-bushfire-prone-areas#_789800e2-b3dc-47df-a2ce-04ac5adc3f01","x":"Delete clause G5D4 and insert NSW G5D4 as follows:\nIn a designated bushfire prone area, a Class 9 building that is a special fire protection purpose or a Class 10a building or deck immediately adjacent or connected to a such a building or part, must comply with—\nfor a Class 9 building that is special fire protection purpose, Specification 43 except as amended by Planning for Bush Fire Protection; or\nfor a Class 10a building or deck immediately adjacent or connected to a Class 9 building that is a special fire protection purpose —\nAS 3959 except as amended by Planning for Bush Fire Protection; and\nS43C13; or\nthe requirements of (a) or (b) above as modified by the development consent or a bushfire safety authority issued under section 100B of the Rural Fires Act 1997.","st":"NSW","base":"G5D4","g":"/ncc/nsw-g5d4"},{"c":"NSW Part G7","t":"Livable housing design","p":"NSW Part G7 Livable housing design","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-g7-livable-housing-design","x":"This Part has deliberately been left blank. Part G7 does not apply in NSW as livable housing design requirements do not apply to sole-occupancy units in a Class 2 building in NSW.","st":"NSW","base":"Part G7","g":"/ncc/nsw-part-g7"},{"c":"NSW I1D1","t":"Application of Part","p":"NSW Part I1 Class 9b buildings","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i1-class-9b-buildings#_adacba53-2e21-4e62-ad99-fd87a83222f0","x":"Delete clause I1D1 and insert NSW I1D1 as follows:\n(1) For a Class 9b building or part of a building that is not an entertainment venue —\nthe Deemed-to-Satisfy Provisions of Part I1 apply to every enclosed Class 9b building or part of a building which—\nis a school assembly, church or community hall with a stage and any backstage area with a total floor area of more than 300 m2; or\notherwise, has a stage and any backstage area with a total floor area of more than 200 m2; or\nhas a stage with an associated rigging loft; and\nnotwithstanding (1)(a)—\nI1D4 applies to every open or enclosed Class 9b building; and\nI1D7 applies to every enclosed Class 9b building.\n(2) For a Class 9b building that is an entertainment venue, NSW Part I4 applies in replacement of Part I1.","st":"NSW","base":"I1D1","g":"/ncc/nsw-i1d1"},{"c":"NSW I4D1","t":"Application of Part","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_cef01c71-2146-4110-b789-278b7d7cd76f","x":"Delete clause I4D1 and insert NSW I4D1 as follows:\nThis Part applies to every entertainment venue as described in the Environmental Planning and Assessment Regulation 2021.","st":"NSW","base":"I4D1","g":"/ncc/nsw-i4d1"},{"c":"NSW I4D2","t":"Fire separation","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_3b795334-9764-42a5-ab6f-f54ca36624fe","x":"Delete clause I4D2 and insert NSW I4D2 as follows:\nIf an entertainment venue forms part only of a building, then—\nthe whole of the entertainment venue; or\nthe part containing the stage, backstage area and auditorium,\nmust be separated from the other parts of the building by construction having an FRL of not less than 60/60/60.","st":"NSW","base":"I4D2","g":"/ncc/nsw-i4d2"},{"c":"NSW I4D3","t":"Foyer space","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_062d2c22-e1f1-4e8d-8eed-ddd7f5464572","x":"Delete clause I4D3 and insert NSW I4D3 as follows:\nWhere an entertainment venue is used principally for the purpose of—\nexhibiting films; or\nconducting live stage productions,\nfoyer space (excluding stairways and concession areas) must be provided on the basis of at least 0.25 m2 for each person that the auditorium accommodates.","st":"NSW","base":"I4D3","g":"/ncc/nsw-i4d3"},{"c":"NSW I4D4","t":"Sprinkler systems for common foyers","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_9c0e81ca-0b86-40d0-8a30-1ca0c5bcc57b","x":"Delete clause I4D4 and insert NSW I4D4 as follows:\nIn an entertainment venue, where multiple auditoriums have a foyer in common, the following applies:\nIf the foyer serves not more than 2 auditoriums, that foyer must be separated from any adjoining foyer by construction having an FRL of not less than 60/60/60.\nIf the foyer serves more than 2 auditoriums, a sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17 must be installed—\nthroughout the storey containing the foyer; and\nthroughout each storey in the building below that storey.","st":"NSW","base":"I4D4","g":"/ncc/nsw-i4d4"},{"c":"NSW I4D5","t":"Conventional stages: application","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_637f6a4d-082c-40f9-8004-0946bd3221ba","x":"Delete clause I4D5 and insert NSW I4D5 as follows:\nNSW I4D6 to NSW I4D9 apply to a conventional stage, that is, a stage which is separated from the auditorium by a proscenium wall incorporating a proscenium opening.","st":"NSW","base":"I4D5","g":"/ncc/nsw-i4d5"},{"c":"NSW I4D6","t":"Conventional stages: extent of stage area","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_78250411-f29f-4242-904e-70a9a786730f","x":"Delete clause I4D6 and insert NSW I4D6 as follows:\nIf a room or area is not separated from the remainder of a conventional stage by construction having an FRL of not less than 60/60/60, the room or area is, for the purposes of this Part, to be taken to form part of the stage.","st":"NSW","base":"I4D6","g":"/ncc/nsw-i4d6"},{"c":"NSW I4D7","t":"Conventional stages: small stages","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_d6fc378f-10f7-4724-83c7-2375c4306133","x":"Delete clause I4D7 and insert NSW I4D7 as follows:\nA stage which is more than 50 m2 but not more than 150 m2 in area must have 2 or more means of egress from the stage and backstage area provided otherwise than through the proscenium wall.","st":"NSW","base":"I4D7","g":"/ncc/nsw-i4d7"},{"c":"NSW I4D8","t":"Conventional stages: large stages","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_59313f49-8661-47a8-bf4a-86708a3c257b","x":"Delete clause I4D8 and insert NSW I4D8 as follows:\nA stage which is more than 150 m2 in area—\nmust have installed directly above the stage a suitable sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17; and\nmust have the proscenium opening protected by a safety curtain that complies with NSW I4D15 and NSW I4D16; and\nmust have a line of open drenchers or open sprinklers provided above the proscenium opening on the stage side and in such a position as to be able to discharge over the inside face of the safety curtain; and\nmust have 2 or more means of egress from the stage and backstage area provided otherwise than through the proscenium wall.","st":"NSW","base":"I4D8","g":"/ncc/nsw-i4d8"},{"c":"NSW I4D9","t":"Conventional stages: fire separation of stages","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_1c490168-6344-4454-b148-b16b1f23c929","x":"Delete clause I4D9 and insert NSW I4D9 as follows:\nA stage which is more than 50 m2 in area, and all areas below such a stage, must (with the exception of the proscenium opening) be separated from the backstage and the remainder of the building by construction having an FRL of not less than 60/60/60.","st":"NSW","base":"I4D9","g":"/ncc/nsw-i4d9"},{"c":"NSW I4D10","t":"Non-conventional stages: application","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_c18adf52-4ed4-459a-a529-56eefc30f1fb","x":"Delete clause I4D10 and insert NSW I4D10 as follows:\nNSW I4D11 and NSW I4D12 apply to a stage that is not a conventional stage within the meaning of NSW I4D5.","st":"NSW","base":"I4D10","g":"/ncc/nsw-i4d10"},{"c":"NSW I4D11","t":"Non-conventional stages: small stages","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_89979eaa-654e-4dbf-ac99-99a1f8d5287f","x":"Delete clause I4D11 and insert NSW I4D11 as follows:\nA stage which is more than 50 m2 but not more than 150 m2 in area must have at least 2 means of egress from the backstage area.","st":"NSW","base":"I4D11","g":"/ncc/nsw-i4d11"},{"c":"NSW I4D12","t":"Non-conventional stages: large stages","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_e813b747-1863-4245-975b-a7b72e611a18","x":"Delete clause I4D12 and insert NSW I4D12 as follows:\nA stage which is more than 150 m2 in area must have at least 2 means of egress from the backstage area.","st":"NSW","base":"I4D12","g":"/ncc/nsw-i4d12"},{"c":"NSW I4D13","t":"Flying scenery","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_36124aae-e0c6-40f3-8b82-09681d91dd69","x":"Delete clause I4D13 and insert NSW I4D13 as follows:\n(1) Where there is a grid or other means of flying scenery over a conventional stage or non-conventional stage —\nthe stage must be provided with a sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17; and\na fly gallery, bridge grid, rigging loft, tie gallery or electric light perch must—\ncomply with AS 1657; and\nbe of non-combustible construction; and\na fly gallery must be provided with at least 2 means of egress, one on each side of the stage; and\na grid or rigging loft must be provided with at least 2 means of egress; and\nif exposed steel is used in the construction of a roof, fly or tie gallery, the roof, fly or tie gallery must be so designed that, in the event of its structural failure due to fire, the wall structure of the building will not be affected; and\nstructural steel supporting the stage tower must be enclosed by masonry or concrete and have an FRL of not less than 120/120/120.\n(2) In addition to (1), in the case of a conventional stage, the following additional requirements apply:\nThe proscenium wall must—\nhave an FRL of not less than 120/120/120; and\nhave the proscenium opening protected by a rigid safety curtain in accordance with NSW I4D16.\nThe walls forming the stage area, and the area beneath the stage, must be constructed of masonry or concrete and have an FRL of not less than 120/120/120.","st":"NSW","base":"I4D13","g":"/ncc/nsw-i4d13"},{"c":"NSW I4D14","t":"Load notice","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_17b248b3-186e-4e1d-b010-3e697d3954e8","x":"Delete clause I4D14 and insert NSW I4D14 as follows:\n(1) A notice indicating the actual distributed and concentrated load for which the stage floor has been designed must be conspicuously and permanently displayed in a position adjacent to the stage floor.\n(2) The notice must be in legible letters and figures—\nat least 50 mm high; and\non a contrasting background.","st":"NSW","base":"I4D14","g":"/ncc/nsw-i4d14"},{"c":"NSW I4D15","t":"Safety curtains","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_baee8254-c03b-43b4-aa0c-d117148f0b49","x":"Delete clause I4D15 and insert NSW I4D15 as follows:\nA safety curtain required by NSW I4D8 must—\nbe made of non-combustible material; and\nbe so fitted that, when it is closed, it forms an efficient smoke seal between the stage and the auditorium; and\nbe capable of withstanding a pressure differential of 0.5 kPa over its entire surface area; and\nbe run on steel guides located on each side of the proscenium opening; and\nremain engaged in its guides if the guides, together with their fittings and attachments and that part of the curtain engaged in the guides, are subjected to a pressure differential of 1 kPa; and\nbe of sufficiently robust construction to withstand damage by scenery, stage properties and falling debris; and\nbe capable of closing the proscenium opening within 30 seconds, either by gravity slide or by motor assisted mechanisms; and\nhave manual controls, located on each side of the stage, for the closing of the curtains; and\nhave a notice displayed adjacent to the operating controls, in clear and legible letters and symbols of adequate size, indicating its use and operation; and\nwhen operated, actuate a distinctive warning alarm audible to persons on the stage and must not be reliant for its operation solely on the primary electricity supply; and\nhave the words “Safety Curtain” exhibited on the curtain in clear and legible letters of adequate size to enable them to be read from all parts of the auditorium.","st":"NSW","base":"I4D15","g":"/ncc/nsw-i4d15"},{"c":"NSW I4D16","t":"Safety curtains — additional requirements","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_abae7c34-c6be-4054-b3fc-2f1859b29285","x":"Delete clause I4D16 and insert NSW I4D16 as follows:\nA rigid safety curtain required by NSW I4D13 must comply with the requirements of NSW I4D15 and it must—\nbe vertically hung from steel cables; and\nbe framed with structural steel that complies with AS 4100; and\nbe sheeted and finished on both sides with sheet steel or other non-combustible material of such gauge, and so fastened to its frame, as to ensure that its frame is capable of withstanding distortion arising from heat; and\nwhen closed, overlap the proscenium opening by not less than 300 mm at each side and by not less than 600 mm at the top.","st":"NSW","base":"I4D16","g":"/ncc/nsw-i4d16"},{"c":"NSW I4D17","t":"Seating in rows: application","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_656e5413-3736-47a9-953b-0bab43294f98","x":"Delete clause I4D17 and insert NSW I4D17 as follows:\nNSW I4D18 to NSW I4D25 do not apply to continental seating or seating at tables.","st":"NSW","base":"I4D17","g":"/ncc/nsw-i4d17"},{"c":"NSW I4D18","t":"Seating in rows: number of seats","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_c84cb754-58a9-431f-b2fb-3d57c5b3d145","x":"Delete clause I4D18 and insert NSW I4D18 as follows:\nSubject to NSW I4D22, where seating is arranged in rows, the maximum number of seats in each row must not exceed—\n8 where there is an aisle at one end only of the row; or\n16 where there are aisles on both ends of the row.","st":"NSW","base":"I4D18","g":"/ncc/nsw-i4d18"},{"c":"NSW I4D19","t":"Seating in rows: chairs used for seating","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_fb1d5290-c014-4ea4-9284-ba3293919ccf","x":"Delete clause I4D19 and insert NSW I4D19 as follows:\nChairs used for seating must—\nwhere they have arms, be at least 500 mm from centre to centre; and\nwhere they do not have arms, be at least 450 mm from centre to centre; and\nhave a minimum lateral clearance of at least 300 mm between—\nthe front of each chair and the back of the chair in front; or\nif a guardrail is provided in front of the chairs, between the front of each chair and the guardrail; and\nhave a distance of at least 950 mm between the back of the chair and the back of the chair in front.","st":"NSW","base":"I4D19","g":"/ncc/nsw-i4d19"},{"c":"NSW I4D20","t":"Seating in rows: chairs in auditoriums — level floors","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_f354e0a0-ad67-4240-a3dd-52406b0dcf11","x":"Delete clause I4D20 and insert NSW I4D20 as follows:\nChairs in an auditorium that has a level floor must be—\nsecurely fastened to the floor; or\nsecured together in groups of not less than 4 and not more than 16.","st":"NSW","base":"I4D20","g":"/ncc/nsw-i4d20"},{"c":"NSW I4D21","t":"Seating in rows: chairs in auditoriums — sloping floors","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_84e0a86d-6321-4035-b3e5-f1e80aaedbb9","x":"Delete clause I4D21 and insert NSW I4D21 as follows:\nChairs in an auditorium having a sloping floor, or having stepped or inclined platforms, must be securely fastened to the floor or platform.","st":"NSW","base":"I4D21","g":"/ncc/nsw-i4d21"},{"c":"NSW I4D22","t":"Seating in rows: radiating aisles in seating areas","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_3bf418ab-0094-4224-8ff2-5800cfe06ad2","x":"Delete clause I4D22 and insert NSW I4D22 as follows:\nWhere seating is securely fastened to the floor and arranged in rows of concentric circles, semi-circles or segments of circles, with radiating aisles —\nthe number of seats in each row between 2 aisles must not exceed 24; and\neach seat must—\nhave a minimum lateral clearance of at least 325 mm between the front of the seat and the back of the seat in front; and\nhave a distance of at least 975 mm between the back of the seat and the back of the seat in front; and\nthe rows may be curved or straight.","st":"NSW","base":"I4D22","g":"/ncc/nsw-i4d22"},{"c":"NSW I4D23","t":"Seating in rows: aisles and cross-overs","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_2d2466de-74de-4d08-a304-b72a341d060c","x":"Delete clause I4D23 and insert NSW I4D23 as follows:\nWhere aisles and cross-overs are provided—\neach aisle must have a width of at least 1000 mm and each cross-over must have a width of at least 1500 mm; and\nthe floor of each aisle must not have a grade of more than 1 in 8 at any part; and\nif there is a step from a row to an aisle or from a landing to an aisle, the step must not project into the aisle.","st":"NSW","base":"I4D23","g":"/ncc/nsw-i4d23"},{"c":"NSW I4D24","t":"Seating in rows: platforms and steps","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_4c0532c6-743a-4440-8828-b2ae4b0e0300","x":"Delete clause I4D24 and insert NSW I4D24 as follows:\nWhere an aisle contains platforms or steps—\nthe platforms and steps must extend for the full width of the aisle; and\nif there are no intervening steps between levels of platforms, the height of the platform riser must not be more than 200 mm; and\nif there are one or more intervening steps between the levels of platforms—\neach riser must be at least 100 mm but not more than 200 mm high; and\neach going must be at least 250 mm deep; and\nrisers and goings must be uniform; and\ngoings which are more than 450 mm deep at platform level must have a grade of not more than 1 in 50; and\nat the entrance from the aisle to each row there must be a clear level floor space, extending the full width of the aisle, of at least 300 mm, measured from the back of the row in front; and\nany going projecting in front of a seat adjacent to an aisle must be protected by a guardrail.","st":"NSW","base":"I4D24","g":"/ncc/nsw-i4d24"},{"c":"NSW I4D25","t":"Seating in rows: stepped platforms","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_dccf8a05-ab59-42cc-9201-287ebc43e528","x":"Delete clause I4D25 and insert NSW I4D25 as follows:\nWhere stepped platforms without chairs or stepped platforms with bench seats, are used for seating—\neach platform must be at least 700 mm deep; and\neach seating space must be at least 450 mm wide, measured along the front of the platform or bench seat; and\neach seating space must be numbered consecutively; and\nat the entrance from the aisle to each row there must be a clear level floor space, extending the full width of the aisle, of at least 300 mm, measured from the back of the row in front; and\nany going projecting in front of a seat adjacent to an aisle must be protected by a guardrail; and\nin the case of stepped platforms with bench seats, there must be at least 300 mm between the back of each seat and the front of the platform behind, or the front of the bench seat behind, whichever is the closer.","st":"NSW","base":"I4D25","g":"/ncc/nsw-i4d25"},{"c":"NSW I4D26","t":"Continental seating: application","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_b5c3ae90-164b-4852-bc8d-22989004ebb0","x":"Delete clause I4D26 and insert NSW I4D26 as follows:\nNSW I4D27 to NSW I4D35 apply to continental seating.","st":"NSW","base":"I4D26","g":"/ncc/nsw-i4d26"},{"c":"NSW I4D27","t":"Continental seating: seating to be fastened","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_e989dccd-9db5-4531-8c33-23e8d880ad36","x":"Delete clause I4D27 and insert NSW I4D27 as follows:\nSeating must be securely fastened to the floor.","st":"NSW","base":"I4D27","g":"/ncc/nsw-i4d27"},{"c":"NSW I4D28","t":"Continental seating: maximum seats per row","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_35e2f572-ac96-4a8f-9081-175d7841e586","x":"Delete clause I4D28 and insert NSW I4D28 as follows:\nThe number of seats in a row must not exceed 120.","st":"NSW","base":"I4D28","g":"/ncc/nsw-i4d28"},{"c":"NSW I4D29","t":"Continental seating: depth of seating","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_014f4329-2d73-4d7c-9f90-55e76df3ba30","x":"Delete clause I4D29 and insert NSW I4D29 as follows:\nThe depth of each row of seating (that is, the distance between the back of the row in front or, if there is a guardrail in front, between the back of the row and the guardrail) must, in respect of a row containing a number of seats specified in Column 1 of NSW Table I4D29, be not less than the distance specified in Column 2 of that Table in respect of that number of seats.\nInsert NSW table (I4D29) I4D29 as follows:\nNSW Table I4D29: Spacing of auditorium seating\nColumn 1: number of seats in rows\nColumn 2: depth of rows (mm)\nColumn 3: clearance between rows (mm)\nNot exceeding 16\n950\n300\n17 - 30\n975\n325\n31 - 45\n1000\n350\n46 - 60\n1025\n375\n61 - 75\n1050\n400\n76 - 90\n1075\n425\n91 - 105\n1100\n450\n106 - 120\n1125\n475","st":"NSW","base":"I4D29","g":"/ncc/nsw-i4d29"},{"c":"NSW I4D30","t":"Continental seating: clearance between rows","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_475c74c3-64c2-4f4e-adde-092eebbbbb22","x":"Delete clause I4D30 and insert NSW I4D30 as follows:\nThe minimum lateral clearance between each row of seating must, in respect of a row containing a number of seats specified in Column 1 of NSW Table I4D29 be not less than the clearance specified in Column 3 of that Table in respect of that number of seats.","st":"NSW","base":"I4D30","g":"/ncc/nsw-i4d30"},{"c":"NSW I4D31","t":"Continental seating: chairs used for seating","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_cc6e8918-c4ce-41e9-81bb-a67d35f54c0b","x":"Delete clause I4D31 and insert NSW I4D31 as follows:\nChairs used for seating must comply with NSW I4D19(a) and (b).","st":"NSW","base":"I4D31","g":"/ncc/nsw-i4d31"},{"c":"NSW I4D32","t":"Continental seating: egress doorways","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_8815f136-93f1-4149-96db-6d52eb0c4995","x":"Delete clause I4D32 and insert NSW I4D32 as follows:\nEgress doorways through the walls of the auditorium —\nmust have an aggregate width of at least twice the sum of the clearances specified in Column 3 of NSW Table I4D29 for each row of the auditorium to be served by those doorways; and\nmust be provided at each end of every fifth row, excluding the first 2 rows and the last 2 rows in the auditorium if those rows each contain no more than 16 seats; and\nmust lead—\ndirectly to a road or open space; or\ninto a foyer or other area giving access to a road or open space; and\nmust be provided with exit signs if the egress doorways are not sufficiently conspicuous.","st":"NSW","base":"I4D32","g":"/ncc/nsw-i4d32"},{"c":"NSW I4D33","t":"Continental seating: clear areas","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_77e3aa85-c960-4599-8387-28221051b125","x":"Delete clause I4D33 and insert NSW I4D33 as follows:\nA clear area—\nmust be provided from each end of each row to an egress doorway in the wall of the auditorium; and\nmust have a width of at least the greater of—\nthe sum of the clearances specified in Column 3 of NSW Table I4D29 for each row; or\n500 mm; and\nif it contains platforms or steps, must comply with NSW I4D24(a), (b), (c), (d) and (f).","st":"NSW","base":"I4D33","g":"/ncc/nsw-i4d33"},{"c":"NSW I4D34","t":"Continental seating: minimum clear space","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_9d033dac-2955-4446-971d-cb3788cc8542","x":"Delete clause I4D34 and insert NSW I4D34 as follows:\nAt the entrance from a row to a clear area, there must be a clear level floor space having a width of at least the clearance specified for the row in Column 3 of NSW Table I4D29.","st":"NSW","base":"I4D34","g":"/ncc/nsw-i4d34"},{"c":"NSW I4D35","t":"Continental seating: doors","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_da4377f6-7b13-42a3-b6f2-284ee2fd9623","x":"Delete clause I4D35 and insert NSW I4D35 as follows:\nA door fitted to the egress doorway in the wall of an auditorium must comply with NSW D3D16 and NSW D3D24(2).","st":"NSW","base":"I4D35","g":"/ncc/nsw-i4d35"},{"c":"NSW I4D36","t":"Provision of guardrails: location","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_277fc44f-56fe-4269-94e7-6eaddc7692d7","x":"Delete clause I4D36 and insert NSW I4D36 as follows:\nGuardrails must be provided—\nalong the fascia of each balcony or box; and\nif there is a stepped floor, along the front edge of each cross-over; and\nwhere NSW I4D37 and NSW I4D38 apply.","st":"NSW","base":"I4D36","g":"/ncc/nsw-i4d36"},{"c":"NSW I4D37","t":"Provision of guardrails: fixed back seats","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_79751ac3-7921-47fd-b1ce-c985d1b16fb4","x":"Delete clause I4D37 and insert NSW I4D37 as follows:\nIf seats with fixed backs are provided, guardrails that extend for the full width of the seating, must be provided at least 500 mm above the platform unless—\nfixed back seats of the next lower level project at least 500 mm above the level of the stepped platform; and\nthere is only one riser between the platform and next lower cross-over.","st":"NSW","base":"I4D37","g":"/ncc/nsw-i4d37"},{"c":"NSW I4D38","t":"Provision of guardrails: steps between platforms","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_ee89900c-9331-42ed-a2d3-e6ab47231a23","x":"Delete clause I4D38 and insert NSW I4D38 as follows:\nIf—\nthere is more than one intervening step in an aisle between levels of platforms, a guardrail must be provided (at a vertical height of at least 660 mm measured above the nosing of each tread and of the upper platform) to the sides of the aisle adjacent to those steps; and\nthere is more than one intervening step in an aisle between levels of platforms, and that aisle is along a wall, a continuous guardrail must be affixed to that wall at a height of at least 865 mm above the nosing of each tread; and\nthe end of the platform or the back of the highest platform does not abut a wall that extends at least 660 mm above the floor level of the platform, a guardrail not less than 660 mm high must be provided—\nat the ends of the platform, extending from the front of the first riser to the back of the highest platform; and\nat the back of the highest platform, extending the full width of the platform; and\nthere is an inclined floor, the raised section of which is not bounded by walls at least 660 mm high, a guardrail must be provided that extends around the perimeter of the raised section at a height of at least 660 mm above the inclined floor level; and\nseating at tables is provided on a stepped platform, a guardrail at least 500 mm high must be provided along the front edge of the platform.","st":"NSW","base":"I4D38","g":"/ncc/nsw-i4d38"},{"c":"NSW I4D39","t":"Guardrails for seating areas: application","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_441f61ee-9bc5-4b49-b36d-762c7aa5bf4b","x":"Delete clause I4D39 and insert NSW I4D39 as follows:\nNSW I4D40 to NSW I4D42 apply to seating areas.","st":"NSW","base":"I4D39","g":"/ncc/nsw-i4d39"},{"c":"NSW I4D40","t":"Guardrails for seating areas: continental seating","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_96d476f2-648b-40cd-b893-3acc1c1ee45f","x":"Delete clause I4D40 and insert NSW I4D40 as follows:\nWhere a guardrail is provided in front of a row of chairs—\nthe distance between the back of each chair in that row, and the guardrail must be not less than the distance specified in Column 2 of NSW Table I4D29 for the number of chairs in that row; and\nthe minimum lateral clearance between the front of each chair in that row and the guardrail must be not less than the clearance specified in Column 3 of NSW Table I4D29 for the number of chairs in that row.","st":"NSW","base":"I4D40","g":"/ncc/nsw-i4d40"},{"c":"NSW I4D41","t":"Guardrails for seating areas: balconies and boxes","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_85cb3856-48db-4f05-be28-0b5b0c0763fc","x":"Delete clause I4D41 and insert NSW I4D41 as follows:\nA guardrail provided along the fascia of a balcony or box—\nif it is located at the foot of a stepped aisle, must have its top surface at least 900 mm above the floor of the balcony or box; and\nif it is not located at the foot of a stepped aisle, must have its top surface at least 750 mm above the floor; and\nif it has a ledge more than 70 mm wide, must have the top surface of the ledge sloping downwards towards the floor of the balcony or box at an angle of at least 30 degrees from the horizontal; and\nmust have an unperforated kerb or toe guard extending for at least 300 mm above the floor.","st":"NSW","base":"I4D41","g":"/ncc/nsw-i4d41"},{"c":"NSW I4D42","t":"Guardrails for seating areas: cross-overs","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_dfdd7a60-5b4f-45d9-8c26-7a5db8f881f8","x":"Delete clause I4D42 and insert NSW I4D42 as follows:\nA guardrail provided along the front edge of a cross-over on a stepped floor—\nmust be at least 750 mm high; and\nmust extend the full distance between aisles, or between a wall and an aisle, or for such other distance as considered necessary.","st":"NSW","base":"I4D42","g":"/ncc/nsw-i4d42"},{"c":"NSW I4D43","t":"Dressing rooms","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_a899d2f4-4369-45f0-8a0c-04435f8e1603","x":"Delete clause I4D43 and insert NSW I4D43 as follows:\nA dressing room or two or more adjoining dressing rooms, having a total floor area of more than 50 m2, must—\nbe separated from other parts of the building by construction having an FRL of not less than 60/60/60; and\nhave at least 2 means of egress as remote from each other as possible, one of which must discharge—\ndirectly to a road or open space; or\nthrough a fire-isolated exit to a road or open space.","st":"NSW","base":"I4D43","g":"/ncc/nsw-i4d43"},{"c":"NSW I4D44","t":"Storerooms","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_05aed367-051f-4ed4-a099-dc2177527cad","x":"Delete clause I4D44 and insert NSW I4D44 as follows:\nA storeroom must be separated from other parts of the building by construction having an FRL of not less than 60/60/60.","st":"NSW","base":"I4D44","g":"/ncc/nsw-i4d44"},{"c":"NSW I4D45","t":"Projection suites: Application","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_bf5f25ed-993e-4a52-a152-25f20e94a96d","x":"Delete clause I4D45 and insert NSW I4D45 as follows:\n(1) NSW I4D45 to NSW I4D48 apply to projection suites.\n(2) A projection suite must be provided in an entertainment venue intended to be used for the showing of films.","st":"NSW","base":"I4D45","g":"/ncc/nsw-i4d45"},{"c":"NSW I4D46","t":"Projection suites: rooms to be provided","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_5189c05f-c243-44c0-91f8-ed1def11091a","x":"Delete clause I4D46 and insert NSW I4D46 as follows:\nA projection suite in accordance with the staffing requirements of Section 72 of the Environmental Planning and Assessment Regulation 2021 must contain either—\na projection room and sanitary accommodation comprising at least 1 closet pan and 1 washbasin, where the projection suite is continually staffed; or\na projection room fitted with the following equipment—\nan automatic fire suppression system in accordance with SSL Appraisal Specification FAS 102 or a sprinkler system complying with AS 2118; and\na smoke detection system which will—\ncomply with AS 1670.1; and\nbe connected to a fire station or other approved monitoring service where arrangements are in place to initiate fire brigade response; and\nclose down all shutters fitted to projection or observation ports; and\nactivate sufficient general lighting to provide a minimum of 40 lux measured at floor level in any auditorium affected; and\noperate a public address system to automatically announce a suitable message from the management of the premises; and\nactivate an audible alarm to immediately indicate to management the presence of smoke in the projection room.","st":"NSW","base":"I4D46","g":"/ncc/nsw-i4d46"},{"c":"NSW I4D47","t":"Projection suites: fire separation","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_dd2361da-072c-4019-b4e1-5361ef739858","x":"Delete clause I4D47 and insert NSW I4D47 as follows:\nA projection suite must be separated from all other internal parts of the building in which it is located by construction having an FRL of not less than 60/60/60.","st":"NSW","base":"I4D47","g":"/ncc/nsw-i4d47"},{"c":"NSW I4D48","t":"Projection suites: concession for protection of some openings","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_444462d6-7806-408b-b1f1-1c64ee18a639","x":"Delete clause I4D48 and insert NSW I4D48 as follows:\nIf a projection or observation port is not more than 0.1 m2 in area—\na metal shutter not less than 1.5 mm thick may be fitted thereto instead of the protection required under NSW C4D12; and\nany metal shutter or protection system must be equipped with a device to permit the closing of the shutter or the protection system from easily accessible operating positions adjacent to each egress doorway from the projection room.","st":"NSW","base":"I4D48","g":"/ncc/nsw-i4d48"},{"c":"NSW I4D49","t":"Basement storeys","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_5c36b94b-16a1-43bb-8a5f-52360f282eae","x":"Delete clause I4D49 and insert NSW I4D49 as follows:\nWhere an entertainment venue includes not more than 2 basement storeys —\nall required exits from the basement must be enclosed in non-combustible construction, with the exception of the main entry or exit; and\nany auditorium and other public areas in the basement must be equipped with an air-handling system that complies with AS 1668.2.","st":"NSW","base":"I4D49","g":"/ncc/nsw-i4d49"},{"c":"NSW I4D50","t":"Basement storeys: more than two","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_6bac5a6a-7568-4d5c-9682-913080de389f","x":"Delete clause I4D50 and insert NSW I4D50 as follows:\nIf the entertainment venue includes more than 2 basement storeys —\nthe construction must be of at least Type B; and\nall required exits from the basement must be enclosed in a fire-resisting shaft having an FRL as required by the relevant Type of construction; and\nthe building must be equipped with a sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17.","st":"NSW","base":"I4D50","g":"/ncc/nsw-i4d50"},{"c":"NSW I4D51","t":"Electric mains installation: main switchboard","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_3b4a9a3b-3f07-4b1b-9650-9175d67e8b32","x":"Delete clause I4D51 and insert NSW I4D51 as follows:\nThe switchboard containing the main isolation switch must—\nbe located in a position that is readily accessible to authorised persons, and to the fire brigade in the case of an emergency; and\nbe enclosed by construction having an FRL of not less than 60/60/60.","st":"NSW","base":"I4D51","g":"/ncc/nsw-i4d51"},{"c":"NSW I4D52","t":"Electric mains installation: circuit protection","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_9f6e394d-559b-4fbf-85f0-b1b5763476cd","x":"Delete clause I4D52 and insert NSW I4D52 as follows:\nProtection of the final sub-circuit originating at a switchboard or distribution board must be by means of circuit breakers.","st":"NSW","base":"I4D52","g":"/ncc/nsw-i4d52"},{"c":"NSW I4D53","t":"Electric mains installation: separate sub-mains","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_c3ff908e-f13a-465e-8013-4328ab632610","x":"Delete clause I4D53 and insert NSW I4D53 as follows:\nWhere an entertainment venue has its mains supply in common with that of another building or where it is a part of a building—\nthe entertainment venue must be served by a separate and independent sub-main from the main switchboard; and\neach sub-main, the consumer’s main and the supply authority’s conductors within the building must be protected against fire by means of—\nmineral-insulated metal-sheathed cables or other cables that provide at least 2 hours’ fire protection; or\nheavy-duty PVC conduit or metallic pipe, concrete encased in walls or slabs with a minimum of 50 mm cover; or\nheavy-duty PVC conduit or metallic pipe, buried at least 500 mm below ground level, for underground cabling.","st":"NSW","base":"I4D53","g":"/ncc/nsw-i4d53"},{"c":"NSW I4D54","t":"Lighting: lighting switches","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_84bbb3e4-5cdb-4982-91de-4adbf620cd1a","x":"Delete clause I4D54 and insert NSW I4D54 as follows:\n(1) Any switch controlling the lighting system must not be accessible.\n(2) Where, during normal use, general lighting may be dimmed or switched off, an override switch to switch on all of the general lighting instantaneously must be installed in the auditorium in a position accessible to management.","st":"NSW","base":"I4D54","g":"/ncc/nsw-i4d54"},{"c":"NSW I4D55","t":"Lighting: lighting levels","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_6d666f87-8697-4ce5-9e7b-28120972d59d","x":"Delete clause I4D55 and insert NSW I4D55 as follows:\nWhere the lamps utilised in the general lighting are of a type that will not relight immediately after the restoration of the primary electricity supply to those lamps—\na time delay or other suitable means must be provided to maintain the emergency lighting for a period not less than that necessary to allow the general lighting lamps to restrike; or\nlamps of a type that will provide immediate lighting must be installed and—\narranged in such a manner as to ensure visual conditions not inferior to those required to be provided by the emergency lighting; and\ncapable of being switched in common with the general lighting and of being controlled also by the override switch required by NSW I4D54(2).","st":"NSW","base":"I4D55","g":"/ncc/nsw-i4d55"},{"c":"NSW I4D56","t":"Lighting: provision of aisle lighting","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_24cd2e7f-764e-43c3-ada1-6d2ae850cac2","x":"Delete clause I4D56 and insert NSW I4D56 as follows:\nWhere general lighting is to be either dimmed or extinguished when the public is in attendance and where the floor is stepped or at an inclination greater than 1 in 12, aisle lights must be provided to illuminate the length of each aisle and the tread of each step therein.","st":"NSW","base":"I4D56","g":"/ncc/nsw-i4d56"},{"c":"NSW I4D57","t":"Lighting: aisle lighting power supply","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_dd779da7-bc4c-4409-8148-95e4d7612e3c","x":"Delete clause I4D57 and insert NSW I4D57 as follows:\nWhere an aisle light is installed in a seat frame, it must be supplied at a voltage of not more than 32 volts AC or 115 volts DC.","st":"NSW","base":"I4D57","g":"/ncc/nsw-i4d57"},{"c":"NSW I4D58","t":"Lighting: aisle lighting alternative lighting supply","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_7c7e27c3-349f-49ae-b17e-b009e577c9f1","x":"Delete clause I4D58 and insert NSW I4D58 as follows:\nAisle lighting must be provided with an alternative electricity supply that—\nis capable of being automatically energised in the event of failure of the primary lighting electricity supply; and\ncomplies with the provisions applying to emergency lighting.","st":"NSW","base":"I4D58","g":"/ncc/nsw-i4d58"},{"c":"NSW I4D59","t":"Automatic smoke-and-heat vents for stages","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_3e9b3dbe-49cc-4d48-b6b4-e15bd3e06912","x":"Delete clause I4D59 and insert NSW I4D59 as follows:\nAn automatic smoke-and-heat vent system required by NSW E2D16(c) for stages and backstages must—\nbe capable of automatic operation by the inclusion of a heat sensing device designed to activate the system at a temperature of not more than 71°C; and\nbe capable of being released manually from positions at either side of the stage and of being fully activated from either position; and\nhave a notice, prominently displayed at each position referred to in (b), clearly indicating the method of activation; and\nhave an openable area of not less than 10 percent of the total area of the stage.","st":"NSW","base":"I4D59","g":"/ncc/nsw-i4d59"},{"c":"NSW I4D60","t":"Solid fuel burning stoves and open fire places","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_953deb34-3d68-46fe-89d4-b3704420764e","x":"Delete clause I4D60 and insert NSW I4D60 as follows:\nSolid fuel burning stoves and open fire places must not be installed in premises designed for the purpose of—\nexhibiting films; or\nconducting live theatre productions.","st":"NSW","base":"I4D60","g":"/ncc/nsw-i4d60"},{"c":"NSW I4D61","t":"Fuel gas cylinders: general","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_a2de6dab-90e2-48a2-869a-2e9f6a496eef","x":"Delete clause I4D61 and insert NSW I4D61 as follows:\nFuel gas cylinders must—\nbe housed in an enclosure that is located outside the building; and\ncomply with the ventilation requirements of AS/NZS 1596.","st":"NSW","base":"I4D61","g":"/ncc/nsw-i4d61"},{"c":"NSW I4D62","t":"Fuel gas cylinders: enclosures","p":"NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i4-entertainment-venues-other-temporary-structures-and-drive-theatres#_b1247aab-2ba8-42c4-b1f1-8dac929d1f7f","x":"Delete clause I4D62 and insert NSW I4D62 as follows:\nAn enclosure referred to in NSW I4D61 —\nmust be located not less than 3 m from any window, door, vent or other opening; and\nif located 3 m or more from a building must—\nhave a concrete base; and\nbe constructed from heavy-gauge chain-wire mesh or other suitable material; and\nbe at least 1.8 m high; and\nbe so designed as to securely contain the gas cylinders in a single line; and\nbe so designed as to allow cross ventilation; and\nif located less than 3 m from a building must—\nhave a concrete base; and\nhave 3 sides constructed from concrete or masonry; and\nhave a concrete roof; and\nbe so designed as to securely contain the gas cylinders in a single line; and\nhave a hinged, heavy-gauge chain-wire door capable of being secured against unauthorised entry; and\nhave its roof at least 600 mm above the uppermost fitting of any fuel gas cylinder housed therein.","st":"NSW","base":"I4D62","g":"/ncc/nsw-i4d62"},{"c":"NSW I5D1","t":"Application of Part","p":"NSW Part I5 Temporary structures","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i5-temporary-structures#_c12cf3c9-6c88-4673-a7a9-7488924da341","x":"Delete clause I5D1 and insert NSW I5D1 as follows:\nThis Part applies to temporary structures used as entertainment venues.","st":"NSW","base":"I5D1","g":"/ncc/nsw-i5d1"},{"c":"NSW I5D2","t":"Exits — exclusions","p":"NSW Part I5 Temporary structures","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i5-temporary-structures#_c68c672b-231b-4fdf-8c05-ea387bc5e6d6","x":"Delete clause I5D2 and insert NSW I5D2 as follows:\nIn this Part, a reference to an entrance or exit does not include a reference to an entrance or exit provided for persons or animals performing in a temporary structure.","st":"NSW","base":"I5D2","g":"/ncc/nsw-i5d2"},{"c":"NSW I5D3","t":"Location of exits","p":"NSW Part I5 Temporary structures","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i5-temporary-structures#_3beb8dba-3ad2-498f-bc68-d3657063e1ba","x":"Delete clause I5D3 and insert NSW I5D3 as follows:\nExits must be so provided and arranged as to afford a ready means of egress from all parts of a temporary structure.","st":"NSW","base":"I5D3","g":"/ncc/nsw-i5d3"},{"c":"NSW I5D4","t":"Exits to be provided","p":"NSW Part I5 Temporary structures","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i5-temporary-structures#_a5981fcd-c837-4dd4-ba0e-fb92f43a4c7b","x":"Delete clause I5D4 and insert NSW I5D4 as follows:\nWithout limiting the generality of NSW I5D3 —\nthe number of exits to be provided for a temporary structure designed to accommodate a number of persons specified in Column 1 of NSW Table I5D4 must be not less than the number of exits specified in Column 2 of that Table in respect of that number of persons; and\nthe aggregate width of the exits to a temporary structure designed to accommodate a number of persons specified in Column 1 of NSW Table I5D4 must be not less than the width specified in Column 3 of that Table in respect of that number of persons.\nInsert NSW table (I5D4) I5D4 as follows:\nNSW Table I5D4: Number of exits and widths\nColumn 1: accommodation provided (persons)\nColumn 2: number of exits required\nColumn 3: Aggregate width of exits (mm)\n1 - 25\n1 - 2\n1000\n26 - 50\n2\n1500\n51 - 75\n2\n2000\n76 - 100\n2\n2500\n101 - 200\n2\n3000\n201 - 400\n3\n4500\n401 - 600\n4\n6000\n601 - 800\n5\n7500\n801 - 1000\n5\n9000\nOver 1000\n5 exits plus one additional exit for each additional 450 persons, or part thereof.\n9000 mm, plus 500 mm for each additional 50 persons or part thereof.\nTable Notes\nWhere only one exit is provided that exit must be at least 1000 mm wide.\nWhere 2 exits are provided each must be at least 500 mm wide.","st":"NSW","base":"I5D4","g":"/ncc/nsw-i5d4"},{"c":"NSW I5D5","t":"Vertical clearance for exits","p":"NSW Part I5 Temporary structures","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i5-temporary-structures#_77a5cea0-468d-40e4-9cb5-6801367109d9","x":"Delete clause I5D5 and insert NSW I5D5 as follows:\nEvery part of an entrance or exit must provide a minimum unobstructed height of 2000 mm and, where the entrance or exit is beneath a stepped seating platform, infilled risers or other approved overhead protection must be provided above the entrance or exit.","st":"NSW","base":"I5D5","g":"/ncc/nsw-i5d5"},{"c":"NSW I5D6","t":"Curtains across exits","p":"NSW Part I5 Temporary structures","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i5-temporary-structures#_684979ad-3e73-4ac0-94bc-fe41a01b5dab","x":"Delete clause I5D6 and insert NSW I5D6 as follows:\nA flap or curtain used to cover an exit must be so designed that, when it is secured, it will not obstruct or impede egress.","st":"NSW","base":"I5D6","g":"/ncc/nsw-i5d6"},{"c":"NSW I5D7","t":"Curtains and blinds","p":"NSW Part I5 Temporary structures","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i5-temporary-structures#_81077aeb-ee87-4d77-9cec-9960de3433fd","x":"Delete clause I5D7 and insert NSW I5D7 as follows:\nCurtains and blinds for use in a temporary structure must comply with NSW Table S7C7.","st":"NSW","base":"I5D7","g":"/ncc/nsw-i5d7"},{"c":"NSW I5D8","t":"Fabrics","p":"NSW Part I5 Temporary structures","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i5-temporary-structures#_196cc391-05db-498a-9ef7-fa5e7edf1bed","x":"Delete clause I5D8 and insert NSW I5D8 as follows:\nFabric that is used in the construction of a temporary structure must have—\na Flammability Index of not more than 6 where used—\nwithin a height of 4 m from the base of the temporary structure; or\nin an air-supported temporary structure without other supporting framework; and\na Flammability Index of not more than 25 in any other case.","st":"NSW","base":"I5D8","g":"/ncc/nsw-i5d8"},{"c":"NSW I5D9","t":"Guardrails","p":"NSW Part I5 Temporary structures","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i5-temporary-structures#_09599050-85cc-4786-84f5-b031cf6dc977","x":"Delete clause I5D9 and insert NSW I5D9 as follows:\n(1) A rigid guardrail must be provided at each end of a stepped or inclined platform, at least 750 mm high above the floor of the platform, and must extend—\nin the case of a stepped platform, from the front of the first riser; and\nin the case of an inclined platform, from the front of the first row of seating,\nto the back of the highest platform and along the rear of that platform for its full width.\n(2) A rigid guardrail must not obstruct any aisle, cross-over or exit.","st":"NSW","base":"I5D9","g":"/ncc/nsw-i5d9"},{"c":"NSW I5D10","t":"Seating","p":"NSW Part I5 Temporary structures","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i5-temporary-structures#_567046fa-30d2-49c1-b416-dd61f989d74f","x":"Delete clause I5D10 and insert NSW I5D10 as follows:\nSeating must be provided in accordance with NSW I4D18, NSW I4D19, NSW I4D20(b), NSW I4D22(a) and (c), NSW I4D23(a) and NSW I4D25(a), (b), (c) and (d).","st":"NSW","base":"I5D10","g":"/ncc/nsw-i5d10"},{"c":"NSW I5D11","t":"Sanitary accommodation","p":"NSW Part I5 Temporary structures","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i5-temporary-structures#_80384c3a-7a91-44b7-8ce3-cf8b164385d4","x":"Delete clause I5D11 and insert NSW I5D11 as follows:\nSuitable sanitary accommodation must be provided at a location convenient to the temporary structure.","st":"NSW","base":"I5D11","g":"/ncc/nsw-i5d11"},{"c":"NSW I5D12","t":"Projection suites","p":"NSW Part I5 Temporary structures","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i5-temporary-structures#_e48bae67-546a-433f-85cb-4c6c3da5ed68","x":"Delete clause I5D12 and insert NSW I5D12 as follows:\nAny projection suite must comply with NSW I4D47 and NSW I4D48.","st":"NSW","base":"I5D12","g":"/ncc/nsw-i5d12"},{"c":"NSW I5D13","t":"Fireplaces and heating","p":"NSW Part I5 Temporary structures","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i5-temporary-structures#_f974fe41-04a7-46ad-9564-de42bce28865","x":"Delete clause I5D13 and insert NSW I5D13 as follows:\nNo fireplace or other form of heating equipment may be installed in a temporary structure, without the consent of the approval authority.","st":"NSW","base":"I5D13","g":"/ncc/nsw-i5d13"},{"c":"NSW I5D14","t":"Electrical services","p":"NSW Part I5 Temporary structures","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i5-temporary-structures#_e6a04a09-7e03-4382-aae8-896d51c6817c","x":"Delete clause I5D14 and insert NSW I5D14 as follows:\nElectrical services connected to the local supply authority’s mains, to a generating plant or to a battery supply must comply with—\nthe requirements of the local supply authority; and\nAS 3002; and\nwhere applicable, AS/NZS 3000; and\nNSW I4D51(a) and NSW I4D53(a).","st":"NSW","base":"I5D14","g":"/ncc/nsw-i5d14"},{"c":"NSW I5D15","t":"Artificial lighting: general","p":"NSW Part I5 Temporary structures","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i5-temporary-structures#_cad7b1a6-60f3-424e-ba1b-bc06870d270d","x":"Delete clause I5D15 and insert NSW I5D15 as follows:\nArtificial lighting must be provided, and must comply with NSW I4D54 and NSW I4D55.","st":"NSW","base":"I5D15","g":"/ncc/nsw-i5d15"},{"c":"NSW I5D16","t":"Emergency lighting","p":"NSW Part I5 Temporary structures","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i5-temporary-structures#_cc7b0787-c3b0-4adb-9716-1645da7d6bc3","x":"Delete clause I5D16 and insert NSW I5D16 as follows:\nEmergency lighting must be provided to the areas provided with artificial lighting under NSW I5D15 and must include a sufficient number of lamps to give a minimum illumination of 0.2 lux at floor level.","st":"NSW","base":"I5D16","g":"/ncc/nsw-i5d16"},{"c":"NSW I5D17","t":"Emergency lighting power supply","p":"NSW Part I5 Temporary structures","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i5-temporary-structures#_ccaee8eb-0e55-4279-8c52-2194f383cbe8","x":"Delete clause I5D17 and insert NSW I5D17 as follows:\nWhere emergency lighting is provided, the capacity of the battery and charging system must be sufficient to provide the illumination required by NSW I5D16 for—\n30 minutes, in respect of a temporary structure designed to accommodate not more than 1000 persons; and\n60 minutes, in respect of a temporary structure designed to accommodate more than 1000 persons.","st":"NSW","base":"I5D17","g":"/ncc/nsw-i5d17"},{"c":"NSW I5D18","t":"Exit signs","p":"NSW Part I5 Temporary structures","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i5-temporary-structures#_797e40c9-7b54-41bf-83a7-099e6b6f14dc","x":"Delete clause I5D18 and insert NSW I5D18 as follows:\nExit signs must be provided above all exits and in such other locations as may be required by NSW E4D6 and must comply with E4D5 and E4D8.","st":"NSW","base":"I5D18","g":"/ncc/nsw-i5d18"},{"c":"NSW I5D19","t":"Fire-fighting services","p":"NSW Part I5 Temporary structures","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i5-temporary-structures#_95f84cd9-cd8b-457b-a304-058296ba775f","x":"Delete clause I5D19 and insert NSW I5D19 as follows:\n(1) Fire-fighting services and appliances must be so provided as to afford adequate protection and must be so located as the approving authority, on the advice of the Commissioner of Fire and Rescue NSW, may require.\n(2) Where required by the approving authority, the fire-fighting services and appliances must comply with Part E1.","st":"NSW","base":"I5D19","g":"/ncc/nsw-i5d19"},{"c":"NSW I6D1","t":"Application of Part","p":"NSW Part I6 Drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i6-drive-theatres#_b7cfa03e-2c2d-449c-98ba-eb0e6b53777b","x":"Delete clause I6D1 and insert NSW I6D1 as follows:\nThis Part applies to drive-in theatres.","st":"NSW","base":"I6D1","g":"/ncc/nsw-i6d1"},{"c":"NSW I6D2","t":"Speaker standards","p":"NSW Part I6 Drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i6-drive-theatres#_c2378627-53e4-48b7-a969-06fada0fc51c","x":"Delete clause I6D2 and insert NSW I6D2 as follows:\nSpeaker standards must—\nbe placed at a minimum of 5.5 m centres in a line along each parking ramp; and\nbe capable of being illuminated throughout any performance so as to be easily distinguishable at all times.","st":"NSW","base":"I6D2","g":"/ncc/nsw-i6d2"},{"c":"NSW I6D3","t":"Lines of speaker standards","p":"NSW Part I6 Drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i6-drive-theatres#_fe4d5e1a-ffde-442d-b970-bbd4ad1e402e","x":"Delete clause I6D3 and insert NSW I6D3 as follows:\nLines of speaker standards along parking ramps must be placed at a distance of not less than 12.2 m apart.","st":"NSW","base":"I6D3","g":"/ncc/nsw-i6d3"},{"c":"NSW I6D4","t":"Electrical services","p":"NSW Part I6 Drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i6-drive-theatres#_1935439d-0cc1-49cf-90f7-501845640481","x":"Delete clause I6D4 and insert NSW I6D4 as follows:\nThe following electrical services must be installed underground—\nthe supply authority’s conductors within the site and the consumer’s mains, unless otherwise approved; and\nelectrical wiring external to any building on the site; and\nall wiring to the speaker standards.","st":"NSW","base":"I6D4","g":"/ncc/nsw-i6d4"},{"c":"NSW I6D5","t":"Vehicular entrances","p":"NSW Part I6 Drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i6-drive-theatres#_10fb6fc4-0760-4ae2-8fe4-a8648f32f980","x":"Delete clause I6D5 and insert NSW I6D5 as follows:\nEach public vehicular entrance to or exit from the drive-in theatre must be capable of being fully illuminated by flood lights that are so placed and so focussed as not to interfere with the vision of the driver of any motor vehicle.","st":"NSW","base":"I6D5","g":"/ncc/nsw-i6d5"},{"c":"NSW I6D6","t":"Lighting","p":"NSW Part I6 Drive-in theatres","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-i6-drive-theatres#_de284f36-aedd-487d-928d-7b409fcd4aa0","x":"Delete clause I6D6 and insert NSW I6D6 as follows:\n(1) Driveways — Entrance and exit driveways, and the perimeter of the holding area, must be capable of being continuously illuminated by lamps capable of producing a minimum illumination of 0.5 lux at ground level.\n(2) Ramp areas — The whole of the ramp area of a drive-in theatre must be capable of being floodlit by means of area flood lights to an illumination of at least 10 lux.","st":"NSW","base":"I6D6","g":"/ncc/nsw-i6d6"},{"c":"NSW J1O1","t":"Objective","p":"NSW Part J1 Energy efficiency performance requirements","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-j1-energy-efficiency-performance-requirements#_3731f6d7-f426-4df5-b8f7-306b23a2aeb6","x":"Insert NSW clause J1O1 in clause J1O1 as follows:\nThe Objective of this Section is to—\nreduce energy consumption and energy peak demand; and\nreduce greenhouse gas emissions; and\nimprove occupant health and amenity.","st":"NSW","base":"J1O1","g":"/ncc/nsw-j1o1"},{"c":"NSW J1F1","t":"Energy efficiency","p":"NSW Part J1 Energy efficiency performance requirements","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-j1-energy-efficiency-performance-requirements#_5e1582ba-9b54-4329-9b70-3b5651da3f64","x":"Insert NSW clause J1F1 in clause J1F1 as follows:\nA building must—\nreduce the energy consumption and energy peak demand of key energy using equipment; and\nreduce the greenhouse gas emissions that occur as a result of a building’s energy consumption and energy source; and\nfor a Class 3 and Class 5 to 9 building, protect occupant health and amenity by ensuring the building envelope assists in the maintenance of acceptable internal conditions while the building is occupied; and\nbe able to accommodate the installation of distributed energy resources.","st":"NSW","base":"J1F1","g":"/ncc/nsw-j1f1"},{"c":"NSW J1P1","t":"Operational energy use and greenhouse gas emissions","p":"NSW Part J1 Energy efficiency performance requirements","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-j1-energy-efficiency-performance-requirements#_785e395a-703b-4da2-b1f9-27284ff5af75","x":"Insert NSW clause J1P1 in clause J1P1 as follows:\nA building including its services, must have features that—\nfacilitate the efficient use of energy and near zero operational greenhouse gas emissions appropriate to—\nthe function and use of the building; and\nthe level of human comfort required for the building use; and\nfor the conditioned space, achieve an hourly regulated energy consumption and associated greenhouse gas emissions, averaged over the annual hours of operation, of not more than—\nfor a Class 6 building, 40 kJ/m².hr; and 4 g of CO2-e/m2.hr; and\nfor a Class 5, 7b, 8 or 9a building other than a ward area, or a Class 9b school, 22 kJ/m².hr, and 2.2 g of CO2-e/m2.hr; and\nfor all other building classifications, 8 kJ/m².hr and 1 g of CO2-e/m2.hr.","st":"NSW","base":"J1P1","g":"/ncc/nsw-j1p1"},{"c":"NSW J1P2","t":"Thermal performance of a Class 4 part of building","p":"NSW Part J1 Energy efficiency performance requirements","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-j1-energy-efficiency-performance-requirements#_dfdd9691-3ec3-4931-a8f8-401f405f420f","x":"Insert NSW clause J1P2 in clause J1P2 as follows:\nThis clause has deliberately been left blank.\nJ1P2 does not apply in NSW as thermal performance of a sole-occupancy unit of a Class 2 building or a Class 4 part of a building is regulated by BASIX.","st":"NSW","base":"J1P2","g":"/ncc/nsw-j1p2"},{"c":"NSW J1P3","t":"Energy usage of a Class 4 part of a building","p":"NSW Part J1 Energy efficiency performance requirements","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-j1-energy-efficiency-performance-requirements#_44cc3351-c25b-4458-8649-e03dac1c42b0","x":"Insert NSW clause J1P3 in clause J1P3 as follows:\nThis clause has deliberately been left blank.\nJ1P3 does not apply in NSW as the thermal performance of a sole-occupancy unit of a Class 2 building or a Class 4 part of a building is regulated by BASIX.","st":"NSW","base":"J1P3","g":"/ncc/nsw-j1p3"},{"c":"NSW J1P4","t":"Renewable energy, energy storage and electric vehicle charging","p":"NSW Part J1 Energy efficiency performance requirements","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-j1-energy-efficiency-performance-requirements#_af3e3629-6f55-41b4-a40d-38938707aa8f","x":"Insert NSW clause J1P4 in clause J1P4 as follows:\nA building must have features that facilitate the future installation of on-site renewable energy generation and energy storage equipment, except where this is already installed to the maximum practicable extent and electric vehicle charging equipment.","st":"NSW","base":"J1P4","g":"/ncc/nsw-j1p4"},{"c":"NSW J1V1","t":"NABERS Energy","p":"NSW Part J1 Energy efficiency performance requirements","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-j1-energy-efficiency-performance-requirements#_6f744ae9-c59b-4556-8c63-a025f7a90ebc","x":"Insert NSW clause J1V1 in clause J1V1 as follows:\n(1) For a Class 5 building, compliance with NSW J1P1 is verified when—\na minimum 6-star NABERS Energy for offices base building Commitment Agreement is obtained; and\nthe energy model required for (a) demonstrates that the base building’s regulated energy greenhouse gas emissions are equivalent to at least the 6.6 star level when excluding—\ntenant supplementary heating and cooling systems; and\nexternal lighting; and\ncarpark services; and\nthe energy model required for (a) demonstrates either—\na thermal comfort level of between a Predicted Mean Vote of -1 to +1 is achieved across not less than 95% of the floor area of all occupied zones for not less than 98% of the annual hours of operation of the building; or\na dry bulb room temperature is maintained across not less than 95% of the floor area of all occupied zones, other than any room containing an indoor swimming pool, for not less than 95% of the annual hours of operation between—\n18°C and 25°C for conditioned spaces with transitory occupancy; and\n21°C and 24°C for all other conditioned spaces; and\nthe building complies with the additional requirements in Specification 33.\n(2) For a Class 3 building, compliance with NSW J1P1 is verified when—\na minimum 4-star NABERS Energy for Hotels Commitment Agreement is obtained; and\nthe operating hours of the services are not less than 12 hours per day in bedrooms, dining rooms and conference facilities, 24 hours per day in corridors and foyers and 18 hours per day in back-of-house areas; and\nthe energy model required for (a) demonstrates that—\nthe regulated energy greenhouse gas emissions are equivalent to at least 5.3 stars; and\na dry bulb room temperature is maintained across not less than 95% of the floor area of all occupied zones, other than any room containing an indoor swimming pool, for not less than 95% of the annual hours of operation between—\n18°C and 25°C for conditioned spaces with transitory occupancy and food preparation areas; and\n21°C and 24°C for all other conditioned spaces; and\nthe space temperature in any indoor swimming pool chamber is maintained at 2°C above the pool temperature during occupied hours of not less than 12 hours per day; and\nthe building complies with the additional requirements in Specification 33.\n(3) For a Class 6 shopping centre, compliance with NSW J1P1 is verified when—\na minimum 6-stars NABERS Energy for Shopping Centres Commitment Agreement is obtained; and\nthe building has:\nan air-conditioned common area of not less than 20% of the gross lettable area; and\na gross lettable area greater than 15 000 m2; and\nthe energy model required for (a) demonstrates—\nthe regulated energy greenhouse gas emissions of the services covered within the scope of NABERS Energy for Shopping Centres ratings are equivalent to at least 6.7 stars when—\nexcluding carpark services and carpark numbers from NABERS Energy calculation; and\ncalculating solar photovoltaic export based on the reduced site energy use arising from (A); and\na dry bulb room temperature is maintained across not less than 95% of the floor area of all occupied zones, other than any room containing an indoor swimming pool, for not less than 95% of the annual hours of operation between—\n18°C and 25°C for conditioned spaces with transitory occupancy and food preparation areas; and\n21°C and 24°C for all other conditioned spaces; and\nthe building complies with the additional requirements in Specification 33.\n(4) The calculation method for (1), (2) and (3) must comply with ANSI/ASHRAE Standard 140.","st":"NSW","base":"J1V1","g":"/ncc/nsw-j1v1"},{"c":"NSW J1V2","t":"Green star","p":"NSW Part J1 Energy efficiency performance requirements","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-j1-energy-efficiency-performance-requirements#_fb291dde-f4cc-4ef8-9473-a6bb8bdcd31f","x":"Insert NSW clause J1V2 in clause J1V2 as follows:\n(1) For a Class 3, 5, 6, 7, 8 or 9 building, compliance with NSW J1P1 is verified when—\nthe building complies with the simulation requirements, and is registered, for a Green Star Buildings rating; and\nthe annual greenhouse gas emissions of the proposed building are less than 90% of the annual greenhouse gas emissions of the reference building; and\nin the proposed building, a thermal comfort level of between a Predicted Mean Vote of -1 to +1 is achieved across not less than 95% of the floor area of all occupied zones for not less than 98% of the annual hours of operation of the building; and\nthe building complies with the additional requirements in Specification 33.\n(2) The calculation method used for (1) must comply with ANSI/ASHRAE Standard 140.","st":"NSW","base":"J1V2","g":"/ncc/nsw-j1v2"},{"c":"NSW J1V3","t":"Verification using a reference building","p":"NSW Part J1 Energy efficiency performance requirements","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-j1-energy-efficiency-performance-requirements#_f39765e3-60bd-4ca0-885e-5556fdf9d56e","x":"Insert NSW clause J1V3 in clause J1V3 as follows:\n(1) For a Class 3, 5, 6, 7, 8 or 9 building, compliance with NSW J1P1 is verified when—\nit is determined that—\nthe annual greenhouse gas emissions of the proposed building are not more than 97% of the annual greenhouse gas emissions of a reference building when the proposed building is modelled with the proposed services; and\nthe annual greenhouse gas emissions of the services of the proposed building are not more than the annual greenhouse gas emissions of a the services of the reference building when the proposed building is modelled with the same services as the reference building; and\nin the proposed building—\nif a Class 5 building, a thermal comfort level of between a Predicted Mean Vote of -1 to +1 is achieved across not less than 95% of the floor area of all occupied zones for not less than 98% of the annual hours of operation of the building; or\na dry bulb room temperature is maintained across not less than 95% of the floor area of all occupied zones other than any room containing an indoor swimming pool, for not less than 95% of the annual hours of operation between—\n18°C and 25°C for conditioned spaces with transitory occupancy; and\n21°C and 24°C for all other conditioned spaces; or\nin climate zone 1, the 98th percentile zone cooling load across the hours of operation does not exceed 110% of the 98th percentile load in the corresponding zone of the reference building, across 95% of the assessable floor area; or\nin climate zone 8, the 98th percentile zone heating load across the hours of operation does not exceed 110% of the 98th percentile load in the corresponding zone of the reference building, across 95% of the assessable floor area; or\nin climate zones 2 to 7—\nthe 98th percentile zone cooling load across the annual hours of operation does not exceed 120% of the 98th percentile load of the corresponding zone of the reference building, across 95% of the assessable floor area; and\nthe 98th percentile zone heating load across the annual hours of operation does not exceed 120% of the 98th percentile load of the corresponding zone of the reference building, across 95% of the assessable floor area; and\nthe building complies with the additional requirements in Specification 33.\n(2) The calculation method used for (1) must comply with—\nANSI/ASHRAE Standard 140; and\nSpecification 34; and\nSpecification 48.","st":"NSW","base":"J1V3","g":"/ncc/nsw-j1v3"},{"c":"NSW J1V4","t":"Verification of building envelope sealing","p":"NSW Part J1 Energy efficiency performance requirements","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-j1-energy-efficiency-performance-requirements#_356af511-ee67-4c1a-9c6a-c182c6270568","x":"Insert NSW clause J1V4 in clause J1V4 as follows:\nCompliance with NSW J1P1(a) is verified for building envelope sealing when the envelope is sealed at an air permeability rate, tested in accordance with Method 1 of AS/NZS ISO 9972, of not more than—\nfor a Class 5, 6, 8 or 9a or 9b building, other than a ward area, in climate zones 1, 7 and 8, 5 m³/hr.m² at 50 Pa reference pressure; or\nfor a Class 3 or 9c building, or a Class 9a ward area in climate zones 1, 3, 4, 6, 7 and 8, 5 m³/hr.m² at 50 Pa reference pressure.","st":"NSW","base":"J1V4","g":"/ncc/nsw-j1v4"},{"c":"NSW J2D1","t":"Deemed-to-Satisfy Provisions","p":"NSW Part J2 Energy efficiency","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-j2-energy-efficiency#_c91f47be-d0a0-476c-ac7f-9161e2fa7321","x":"Delete subclause J2D1(1) and insert NSW J2D1(1) as follows:\n(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements NSW J1P1 and NSW J1P4 are satisfied by complying with—\nNSW J2D2; and\nNSW J4D2 to J4D7; and\nNSW J5D2 to J5D8; and\nJ6D2 to J6D13; and\nJ7D2 to J7D9; and\nNSW J8D2 to J8D5; and\nNSW J9D2 to J9D5.","st":"NSW","base":"J2D1","g":"/ncc/nsw-j2d1"},{"c":"NSW J2D2","t":"Application of Section J","p":"NSW Part J2 Energy efficiency","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-j2-energy-efficiency#_07db90c0-4b63-46aa-835e-27e23137bbfe","x":"Delete clause J2D2 and insert NSW J2D2 as follows:\n(1) For a Class 3 and 5 to 9 building, Performance Requirement NSW J1P1 is satisfied by complying with—\nPart J4, for the building fabric; and\nPart J5, for building sealing; and\nPart J6, for air-conditioning and ventilation; and\nPart J7, for artificial lighting and power; and\nPart J8, for heated water supply and swimming pool and spa pool plant; and\nJ9D3, for facilities for energy monitoring; and\nJ9D5(2) to (4), for onsite renewable energy systems.\n(2) For a Class 3 and Class 5 to 9 building, Performance Requirement NSW J1P4 is satisfied by complying with J9D4(1), J9D4(2) and J9D5(1).","st":"NSW","base":"J2D2","g":"/ncc/nsw-j2d2"},{"c":"NSW Part J3","t":"Elemental provisions for a Class 4 part of a building","p":"NSW Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-j3-elemental-provisions-class-4-part-building","x":"This Part has deliberately been left blank. Section J of NCC 2025 Volume One does not apply to a Class 4 part of building in NSW.","st":"NSW","base":"Part J3","g":"/ncc/nsw-part-j3"},{"c":"NSW J4D1","t":"Deemed-to-Satisfy Provisions","p":"NSW Part J4 Building fabric","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-j4-building-fabric#_1514a6aa-2794-4b78-94b0-cc2f1a75caa2","x":"Delete subclause J4D1(1) and insert NSW J4D1(1) as follows:\n(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements NSW J1P1 and NSW J1P4 are satisfied by complying with—\nNSW J2D2; and\nNSW J4D2 to J4D7; and\nNSW J5D2 to J5D8; and\nJ6D2 to J6D13; and\nJ7D2 to J7D9; and\nNSW J8D2 to J8D5; and\nNSW J9D2 to J9D5.","st":"NSW","base":"J4D1","g":"/ncc/nsw-j4d1"},{"c":"NSW J4D2","t":"Application of Part","p":"NSW Part J4 Building fabric","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-j4-building-fabric#_e40c4b7d-bdbb-4c07-9059-589f3c8b0894","x":"Delete clause J4D2 and insert NSW J4D2 as follows:\nThe Deemed-to-Satisfy Provisions of this Part apply to building elements forming the envelope of a Class 3 and Class 5 to 9 building.","st":"NSW","base":"J4D2","g":"/ncc/nsw-j4d2"},{"c":"NSW J5D1","t":"Deemed-to-Satisfy Provisions","p":"NSW Part J5 Building sealing","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-j5-building-sealing#_497a4898-d515-4630-a565-18c82b2b34c0","x":"Delete subclause J5D1(1) and insert NSW J5D1(1) as follows:\n(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements NSW J1P1 and NSW J1P4 are satisfied by complying with—\nNSW J2D2; and\nNSW J4D2 to J4D7; and\nNSW J5D2 to J5D8; and\nJ6D2 to J6D13; and\nJ7D2 to J7D9; and\nNSW J8D2 to J8D5; and\nNSW J9D2 to J9D5.","st":"NSW","base":"J5D1","g":"/ncc/nsw-j5d1"},{"c":"NSW J5D2","t":"Application of Part","p":"NSW Part J5 Building sealing","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-j5-building-sealing#_a94e846a-2ee7-40df-82ef-70cbfc42470d","x":"Delete clause J5D2 and insert NSW J5D2 as follows:\nThe Deemed-to-Satisfy Provisions of this Part apply to elements forming the envelope of a Class 3 and Class 5 to 9 building, other than—\na building in climate zones 1, 2, 3 and 5 where the only means of air-conditioning is by using an evaporative cooler; or\na permanent building opening, in a space where a gas appliance is located, that is necessary for the safe operation of a gas appliance; or\na building or space where the mechanical ventilation required by Part F6 provides sufficient pressurisation to prevent infiltration; or\nparts of buildings that cannot be fully enclosed.","st":"NSW","base":"J5D2","g":"/ncc/nsw-j5d2"},{"c":"NSW J6D1","t":"Deemed-to-Satisfy Provisions","p":"NSW Part J6 Air-conditioning and ventilation","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-j6-air-conditioning-and-ventilation#_621f5826-a823-419b-b942-6cf2d6856365","x":"Delete subclause J6D1(1) and insert NSW J6D1(1) as follows:\n(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements NSW J1P1 and NSW J1P4 are satisfied by complying with—\nNSW J2D2; and\nNSW J4D2 to J4D7; and\nNSW J5D2 to J5D8; and\nJ6D2 to J6D13; and\nJ7D2 to J7D9; and\nNSW J8D2 to J8D5; and\nNSW J9D2 to J9D5.","st":"NSW","base":"J6D1","g":"/ncc/nsw-j6d1"},{"c":"NSW J6D3","t":"Air-conditioning system control","p":"NSW Part J6 Air-conditioning and ventilation","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-j6-air-conditioning-and-ventilation#_dc9b9e6f-d03c-4ec1-a365-2c14b7591db4","x":"Delete subclause J6D3(5) and insert NSW J6D3(5) as follows:\n(5) The requirements of (3) and (4) do not apply to—\nan air-conditioning system that serves only one sole-occupancy unit in a Class 3 or 9c building; or\na conditioned space where air-conditioning is needed for 24 hour continuous use.","st":"NSW","base":"J6D3","g":"/ncc/nsw-j6d3"},{"c":"NSW J6D4","t":"Mechanical ventilation system control","p":"NSW Part J6 Air-conditioning and ventilation","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-j6-air-conditioning-and-ventilation#_3550e014-5102-4a87-a811-4b250d593839","x":"Delete subclause J6D4(1) and insert NSW J6D4(1) as follows:\n(1) A mechanical ventilation system, including one that is part of an air-conditioning system, must be capable of being deactivated when the building or part of the building served by that system is not occupied.\nDelete subclause J6D4(6) and insert NSW J6D4(6) as follows:\n(6) The requirements of (2), (4) and (5) do not apply to a mechanical ventilation system that serves only one sole-occupancy unit in a Class 3 or 9c building.","st":"NSW","base":"J6D4","g":"/ncc/nsw-j6d4"},{"c":"NSW J6D12","t":"Unitary air-conditioning equipment","p":"NSW Part J6 Air-conditioning and ventilation","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-j6-air-conditioning-and-ventilation#_969ae525-6c3a-4a25-b472-3f47c28d1060","x":"Delete subclause J6D12(5) and insert NSW J6D12(5) as follows:\n(5) The requirements of (2) to (4) do not apply to unitary air-conditioners with a rated cooling capacity of less than 10kW.","st":"NSW","base":"J6D12","g":"/ncc/nsw-j6d12"},{"c":"NSW J7D1","t":"Deemed-to-Satisfy Provisions","p":"NSW Part J7 Artificial lighting and power","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-j7-artificial-lighting-and-power#_74141f49-3b84-497d-83c0-5035940218fc","x":"Delete subclause J7D1(1) and insert NSW J7D1(1) as follows:\n(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements NSW J1P1 and NSW J1P4 are satisfied by complying with—\nNSW J2D2; and\nNSW J4D2 to J4D7; and\nNSW J5D2 to J5D8; and\nJ6D2 to J6D13; and\nJ7D2 to J7D9; and\nNSW J8D2 to J8D5; and\nNSW J9D2 to J9D5.","st":"NSW","base":"J7D1","g":"/ncc/nsw-j7d1"},{"c":"NSW J7D3","t":"Artificial lighting","p":"NSW Part J7 Artificial lighting and power","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-j7-artificial-lighting-and-power#_041c04a3-0bb7-4fc6-a844-9277e59b9d83","x":"Delete subclause J7D3(1) and insert NSW J7D3(1) as follows:\n(1) This subclause does not apply in NSW.\nDelete subclause J7D3(2) and insert NSW J7D3(2) as follows:\n(2) In a Class 3 or Class 5 to 9 building—\nfor artificial lighting, the aggregate design illumination power load must not exceed the sum of the allowances obtained by multiplying the area of each space by the maximum illumination power density in Table J7D3a; and\nthe aggregate design illumination power load in (a) is the sum of the design illumination power loads in each of the spaces served; and\nwhere there are multiple lighting systems serving the same space, the design illumination power load for (b) is—\nthe total illumination power load of all systems; or\nwhere a control system permits only one system to operate at a time based on the highest illumination power load; or determined by the formula— [formula] In the formula at (c)(ii)—\n[formula] = the highest illumination power load; and\n[formula] = the time for which the maximum illumination power load will occur, expressed as a percentage; and\n[formula] = the predominant illumination power load.","st":"NSW","base":"J7D3","g":"/ncc/nsw-j7d3"},{"c":"NSW J7D4","t":"Interior artificial lighting and power control","p":"NSW Part J7 Artificial lighting and power","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-j7-artificial-lighting-and-power#_beb9e656-e948-4211-ad53-37d156fbe410","x":"Delete subclause J7D4(1) and insert NSW J7D4(1) as follows:\n(1) This subclause does not apply in NSW.\nDelete subclause J7D4(2) and insert NSW J7D4(2) as follows:\n(2) Subject to (3) to (12), in a Class 3 building and Class 5 to 9 building all artificial lighting must be controlled by demand-operated control devices in accordance with Specification 40.","st":"NSW","base":"J7D4","g":"/ncc/nsw-j7d4"},{"c":"NSW J8D1","t":"Deemed-to-Satisfy Provisions","p":"NSW Part J8 Heated water supply and swimming pool and spa pool plant","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-j8-heated-water-supply-and-swimming-pool-and-spa-pool-plant#_1152442e-cd6c-426f-9866-2ae58b40cb14","x":"Delete subclause J8D1(1) and insert NSW J8D1(1) as follows:\n(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements NSW J1P1 and NSW J1P4 are satisfied by complying with—\nNSW J2D2; and\nNSW J4D2 to J4D7; and\nNSW J5D2 to J5D8; and\nJ6D2 to J6D13; and\nJ7D2 to J7D9; and\nNSW J8D2 to J8D5; and\nNSW J9D2 to J9D5.","st":"NSW","base":"J8D1","g":"/ncc/nsw-j8d1"},{"c":"NSW J8D2","t":"Application of Part","p":"NSW Part J8 Heated water supply and swimming pool and spa pool plant","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-j8-heated-water-supply-and-swimming-pool-and-spa-pool-plant#_19b76b9b-138f-4e22-9cf3-974cd2de2521","x":"Delete clause J8D2 and insert NSW J8D2 as follows:\nThe Deemed-to-Satisfy Provisions of this Part apply to a Class 3 and Class 5 to 9 building.","st":"NSW","base":"J8D2","g":"/ncc/nsw-j8d2"},{"c":"NSW J9D1","t":"Deemed-to-Satisfy Provisions","p":"NSW Part J9 Energy monitoring and on-site distributed energy resources","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-j9-energy-monitoring-and-site-distributed-energy-resources#_7b65aeb2-b63a-47ee-ba07-1ba0ff48e8a2","x":"Delete subclause J9D1(1) and insert NSW J9D1(1) as follows:\n(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements NSW J1P1 and NSW J1P4 are satisfied by complying with—\nNSW J2D2; and\nNSW J4D2 to J4D7; and\nNSW J5D2 to J5D8; and\nJ6D2 to J6D13; and\nJ7D2 to J7D9; and\nNSW J8D2 to J8D5; and\nNSW J9D2 to J9D5.","st":"NSW","base":"J9D1","g":"/ncc/nsw-j9d1"},{"c":"NSW J9D2","t":"Application of Part","p":"NSW Part J9 Energy monitoring and on-site distributed energy resources","u":"/editions/ncc-2025/adopted/volume-one/5-new-south-wales/nsw-j9-energy-monitoring-and-site-distributed-energy-resources#_098cbaba-cbb6-4639-8abb-d57e4b36197e","x":"Delete clause J9D2 and insert NSW J9D2 as follows:\nThe Deemed-to-Satisfy Provisions of this Part do not apply to a Class 8 electricity network substation.","st":"NSW","base":"J9D2","g":"/ncc/nsw-j9d2"},{"c":"NT S28C1","t":"Scope","p":"NT Specification 28 Sound insulation for building elements","u":"/editions/ncc-2025/adopted/volume-one/6-northern-territory/nt-28-sound-insulation-building-elements#_39b1bb3c-ca23-41fc-9f1a-8bfe901ac4d9","x":"Delete clause S28C1 and insert NT S28C1 as follows:\nThis Specification lists the weighted sound reduction index RW for some common forms of construction.","st":"NT","base":"S28C1","g":"/ncc/nt-s28c1"},{"c":"NT S28C2","t":"Construction deemed-to-satisfy","p":"NT Specification 28 Sound insulation for building elements","u":"/editions/ncc-2025/adopted/volume-one/6-northern-territory/nt-28-sound-insulation-building-elements#_bed7cf87-c97b-4a11-8a67-bfa8691effa7","x":"Delete clause S28C2 and insert NT S28C2 as follows:\nThe forms of construction listed in NT S28C3 are considered to have the RW stated in that clause if installed as follows:\nMasonry: units must be laid with all joints filled solid, including those between the masonry and any adjoining construction.\nConcrete slabs: joints between concrete slabs and any adjoining construction must be filled solid.\nPlasterboard—\nif one layer is required under this Specification, it must be screw-fixed to the studs with joints staggered on opposite faces; and\nif 2 layers are required, the first layer must be fixed according to (i) and the second layer must be fixed to the first layer with nails, screws or adhesive so that the joints do not coincide with those of the first layer; and\njoints between sheets or between sheets and any adjoining construction must be taped and filled solid; and\nfire-protective grade plasterboard must be the special grade manufactured for use in fire-resisting construction.\nSteel studs and perimeter members—\nthe section of steel must be not less than 0.6 mm thick; and\nstuds must be not less than 63 mm in depth unless another depth is listed in NT S28C3; and\nstuds must be fixed to steel top and bottom plates of sufficient depth to permit secure fixing of the plasterboard; and\nall steel members at the perimeter of the wall must be securely fixed to the adjoining structure and be bedded in resilient compound or the joints must be caulked so that there are no voids between the steel members and the wall.","st":"NT","base":"S28C2","g":"/ncc/nt-s28c2"},{"c":"NT S28C3","t":"RW applicable to construction","p":"NT Specification 28 Sound insulation for building elements","u":"/editions/ncc-2025/adopted/volume-one/6-northern-territory/nt-28-sound-insulation-building-elements#_bda87319-45f9-4a41-b7d3-f56f99083845","x":"Delete clause S28C3 and insert NT S28C3 as follows:\n(1) Construction in accordance with the following has an RW of not less than 45:\nWalls — clay brickwork:\n230 mm thick in one or more leaves and with a mass per unit area of not less than 290 kg/m2.\n110 mm thick rendered 13 mm thick on both sides with a mass per unit area of the unrendered wall being not less than 190 kg/m2.\n110 mm thick, of semi-dry-pressed bricks and rendering 13 mm on one side, the mass per unit area being not less than 215 kg/m2.\n110 mm thick, of extruded brick and rendered 13 mm on one side, the mass per unit area being not less than 180 kg/m2.\nWalls — concrete brickwork: 110 mm thick with a mass per unit area of not less than 195 kg/m2.\nWalls — concrete blockwork:\n190 mm thick with a mass per unit area of not less than 215 kg/m2.\n140 mm thick, the wall thickness of the blocks being not less than 44 mm and with—\n50 mm x 50 mm timber battens spaced at not more than 610 mm centres screw-fixed on one face of the blocks into resilient plugs with rubber inserts between the battens and the wall; and\nthe face of the battens clad with 13 mm thick standard plasterboard; and\na mass per unit area of the whole system of not less than 220 kg/m2.\nWalls — concrete:\nIn-situ concrete — 125 mm thick and with a density of not less than 2200 kg/m3.\nIn-situ concrete — 100 mm thick and with a density of not less than 2500 kg/m3.\nPrecast concrete — 100 mm thick and without joints.\nWalls — steel stud walling:\nWith 2 layers of 16 mm thick fire-protective grade plasterboard fixed to each face.\nWith—\n1 layer of 13 mm thick fire-protective grade plasterboard fixed to one face, and before fixing, 50 mm thick mineral or glass wool blanket or batts stapled to the back of each sheet so that the sheet is completely covered; and\n2 layers of 13 mm thick fire-protective grade plasterboard fixed to the other face.\nWith—\n1 layer of 16 mm thick fire-protective grade plasterboard fixed to one face; and\n50 mm thick mineral or glass wool blanket or batts wedged firmly between the studs; and\n2 layers of fire-protective grade plasterboard fixed to the other face, the inner layer being 16 mm thick and the outer layer being 13 mm.\nWith 2 layers of 13 mm plasterboard on both sides of 75 mm studs.\nFloors — concrete:\nIn-situ concrete slab — 125 mm thick and with a density of not less than 2200 kg/m3.\nIn-situ concrete slab — 100 mm thick and with a density of not less than 2500 kg/m3.\nPre-cast concrete slab — 100 mm thick and without joints.\nFloors — timber, comprising—\ntimber joists not less than 175 mm x 50 mm; and\n75 mm thick mineral or glass wool blanket or batts cut to fit tightly between joists and laid on 10 mm thick plasterboard fixed to underside of joists; and\n25 mm thick mineral or glass wool blanket or batts laid over entire floor, including tops of joists before flooring is laid; and\ntongued and grooved boards not less than 19 mm thick, secured to 75 mm x 50 mm battens; and\nthe assembled flooring laid over the joists, but not fixed to them, with the battens lying between the joists.\n(2) Ducts or other construction separating soil and waste pipes from units, constructed in accordance with the following, have an RW of not less than 30:\nMasonry — not less than 90 mm thick.\nPlasterboard — 2 layers of plasterboard:\nEach 10 mm thick, fixed to timber studs not less than 75 mm x 50 mm and spaced at not more than 400 mm centres.\nEach 13 mm thick, one on each side of steel studs not less than 50 mm deep and spaced at not more than 400 mm centres.","st":"NT","base":"S28C3","g":"/ncc/nt-s28c3"},{"c":"NT S29C1","t":"Scope","p":"NT Specification 29 Impact sound – test of equivalence","u":"/editions/ncc-2025/adopted/volume-one/6-northern-territory/nt-29-impact-sound-test-equivalence#_7570686c-a5e5-43bf-aa0c-45bac977e775","x":"Delete clause S29C1 and insert NT S29C1 as follows:\nThis Specification describes a method of test to determine the comparative resistance of walls to the transmission of impact sound.","st":"NT","base":"S29C1","g":"/ncc/nt-s29c1"},{"c":"NT S29C2","t":"Construction to be tested","p":"NT Specification 29 Impact sound – test of equivalence","u":"/editions/ncc-2025/adopted/volume-one/6-northern-territory/nt-29-impact-sound-test-equivalence#_0f0b7895-5514-4139-b484-b6fdce1dfc0f","x":"Delete clause S29C2 and insert NT S29C2 as follows:\n(1) The test is conducted on a specimen of prototype wall construction and on a specimen of one or other of the constructions specified in NT S28C3.\n(2) The testing of construction specified in NT S28C3 need not be repeated for subsequent comparisons provided complete records of the results, the test equipment and the technique of testing are kept so that identical equipment can be employed and an identical technique can be adopted in the testing of specimens of prototype wall construction.","st":"NT","base":"S29C2","g":"/ncc/nt-s29c2"},{"c":"NT S29C3","t":"Method","p":"NT Specification 29 Impact sound – test of equivalence","u":"/editions/ncc-2025/adopted/volume-one/6-northern-territory/nt-29-impact-sound-test-equivalence#_9d2140b9-e150-439c-bd9b-6f8a97ef0495","x":"Delete clause S29C3 and insert NT S29C3 as follows:\n(1) The wall constructions to be compared must be tested in accordance with AS 1191.\n(2) A horizontal steel platform 510 mm x 460 mm x 10 mm thick must be placed with one long edge in continuous and direct contact with the wall to be tested on the side of the wall on which the impact sound is to be generated.\n(3) A tapping machine complying with ISO 140/6 — 1998 (E) must be mounted centrally on the steel platform.\n(4) The sound transmission through the wall must be determined in accordance with AS 1191 except that the tapping machine as mounted on the steel platform must be used as the source of sound.\n(5) The impact sound pressure levels measured in the receiving room must be converted into normalised levels using a reference equivalent absorption area of 10m2.","st":"NT","base":"S29C3","g":"/ncc/nt-s29c3"},{"c":"NT S4C3","t":"Strengthened area","p":"NT Specification 4 Design of buildings in cyclonic areas","u":"/editions/ncc-2025/adopted/volume-one/6-northern-territory/nt-4-design-buildings-cyclonic-areas#_7e4a01e3-1107-4367-95d6-19492d79b97a","x":"Insert NT clause S4C3 in clause S4C3 as follows:\n(1) Where a residential building of Class 1b, 2, 3, 9a or 9c, in Region B2 or C as defined by AS/NZS 1170.2 and AS 4055, is designed to be used by the occupants with a disability and the vulnerable, it shall incorporate a “strengthened area” for use as shelter during cyclonic conditions and must comply with the following criteria:\nThe floor area of the “strengthened area” is to be calculated at the rate of 1.2 m2 per person normally accommodated within the building.\nThe design wind pressure for the overall “strengthened area” is for an Importance Level 3 building.\nThe minimum standard of debris protection to walls, floors and ceilings (or roof) bounding the \"strengthened area\" shall be that which resists (without complete penetration) the impact loading specified in AS/NZS 1170.2, using a regional wind speed associated with an Importance Level 3 building.\nAll doors, windows, vents and the like in walls bounding the “strengthened area” are to be protected against windborne debris with permanently installed screens in accordance with (c).\nConsideration must be given to the selection of materials and fittings to ensure doors, windows and vents can withstand the required design wind pressures.\nAll doors serving as required entries/exits to a “strengthened area” are to be inward opening with locking devices suitably noted for use in a cyclone emergency.\n(2) The term “strengthened area” is defined as the strengthening of an area to increase its potential to facilitate debris protection.","st":"NT","base":"S4C3","g":"/ncc/nt-s4c3"},{"c":"NT B1D4","t":"Determination of structural resistance of materials and forms of construction","p":"NT Part B1 Structural provisions","u":"/editions/ncc-2025/adopted/volume-one/6-northern-territory/nt-b1-structural-provisions#_e22a19da-1472-40b2-9442-090ab11f261d","x":"Delete clause B1D4 and insert NT B1D4 as follows:\nThe structural resistance of materials and forms of construction must be determined in accordance with the following, as appropriate:\nMasonry (including masonry-veneer, unreinforced masonry and reinforced masonry): AS 3700, except—\n‘(for piers—isolated or engaged)’ is removed from Clause 8.5.1(d); and\nwhere Clause 8.5.1 requires design as for unreinforced masonry in accordance with Section 7, the member must also be designed as unreinforced masonry in accordance with Tables 10.3 and 4.1(a)(i)(C) of AS 3700.\nConcrete:\nConcrete construction (including reinforced and prestressed concrete): AS 3600.\nAutoclaved aerated concrete: AS 5146.1 and AS 5146.3.\nPost-installed and cast-in fastenings: AS 5216.\nSteel construction:\nSteel structures: AS 4100.\nCold-formed steel structures: AS/NZS 4600.\nResidential and low-rise steel framing: NASH Standard – Residential and Low-Rise Steel Framing Part 1 or Part 2.\nComposite steel and concrete: AS/NZS 2327.\nAluminium construction: AS/NZS 1664.1 or AS/NZS 1664.2.\nTimber construction:\nDesign of timber structures: AS 1720.1.\nTimber structures: AS 1684.2, AS 1684.3 or AS 1684.4.\nNailplated timber roof trusses: AS 1720.5.\nPiling: AS 2159.\nGlazed assemblies:\nThe following glazed assemblies in an external wall must comply with AS 2047:\nWindows excluding those listed in (ii).\nSliding and swinging glazed doors with a frame, including french and bi-fold doors with a frame.\nAdjustable louvres.\nShopfronts.\nWindow walls with one piece framing.\nAll glazed assemblies not covered by (i) and the following glazed assemblies must comply with AS 1288:\nAll glazed assemblies not in an external wall.\nRevolving doors.\nFixed louvres.\nSkylights, roof lights and windows in other than the vertical plane.\nSliding and swinging doors without a frame.\nWindows constructed on site and architectural one-off windows, which are not design tested in accordance with AS 2047.\nSecond-hand windows, re-used windows and recycled windows.\nHeritage windows.\nGlazing used in balustrades and sloping overhead glazing.\nTermite Risk Management: Where a primary building element is subject to attack by subterranean termites—\nAS 3660.1 with additional protection measures to be used in areas where Mastrotermes Darwiniensis are prevalent; and\nfor the purposes of this provision, a primary building element consisting entirely of, or a combination of, any of the following materials is considered not to be subject to termite attack:\nSteel, aluminium or other metals.\nConcrete.\nMasonry.\nFibre-reinforced cement.\nTimber in areas where Mastrotermes Darwiniensis are not prevalent — naturally termite resistant in accordance with Appendix C of AS 3660.1.\nTimber — preservative treated in accordance with Appendix D of AS 3660.1; and\nwhere a termite risk management system in accordance with AS 3660.1 is used, a durable notice must be permanently fixed to the building in a prominent location, such as a meter box or the like, indicating—\nthe method of termite risk management; and\nthe date of installation of the system; and\nwhere a chemical is used, its life expectancy as listed on the appropriate authority’s pesticides register label; and\nthe installer’s or manufacturer’s recommendations for the scope and frequency of future inspections for termite activity.\nRoof construction (except in cyclonic areas):\nRoof tiling: AS 2050.\nCellulose cement corrugated sheets: AS/NZS 2908.1 with safety mesh installed in accordance with AS/NZS 1562.3 clause 2.4.3.2 except for sub-clause (g) for plastic sheeting.\nMetal roofing: AS 1562.1.\nRoof construction (cyclone area):\nMetal roofing: AS 1562.1 and Specification 4.\nParticle Board Structural Flooring: AS 1860.2.\nGarage doors and other large access doors in openings not more than 3 m in height in external walls of buildings determined as being located in wind region B2, C or D in accordance with AS/NZS 1170.2: AS/NZS 4505.\nLift shafts which are not required to have an FRL, must—\nexcept as required by (ii), be completely enclosed with non-perforated material between the bottom of the pit and the ceiling of the lift shaft, other than—\nat landing doors, emergency doors and pit access doors; and\nlow-rise, low-speed constant pressure lifts.\nin atrium and observation areas, be protected with non-perforated material not less than 2.5 m in height—\nabove any places on which a person can stand, which are within 800 mm horizontal reach of any vertical moving lift component including ropes and counterweights; and\nat the lowest level of the atrium area that the lift serves, on all sides except the door opening, for not less than 2.5 m in height, by enclosure with non-perforated material; and\nbe of non-brittle material; and\nwhere glazing is used—\ncomply with Table B1D4; or\nnot fail the deflection criteria required by S6C11(c)(iii).\nInsert NT table (B1D4) B1D4 as follows:\nNT Table B1D4: Material and minimum thickness of glazing and polycarbonate sheet\nApplication\nLift shaft vision panels more than 65,000 mm2, door panels, and lift shafts\nLift shaft vision panels less than or equal to 65,000 mm2\nLaminated glass\n10 mm (0.76 mm interlayer)\n6 mm (0.76 mm interlayer)\nToughened/laminated glass\n10 mm (0.76 mm interlayer)\n6 mm (0.76 mm interlayer)\nAnnealed glass with security polyester film coating\n10 mm\n6 mm\nSafety wire glass\nNot applicable\nSubject to fire test\nPolycarbonate sheet\n13 mm\n6 mm","st":"NT","base":"B1D4","g":"/ncc/nt-b1d4"},{"c":"NT E1D10","t":"Where sprinklers are required: Class 9a and 9c buildings","p":"NT Part E1 Fire fighting equipment","u":"/editions/ncc-2025/adopted/volume-one/6-northern-territory/nt-e1-fire-fighting-equipment#_c0f81e37-c446-44bb-a00a-2c6b67610ee0","x":"Delete clause E1D10 and insert NT E1D10 as follows:\n(1) In a Class 9a health-care building used as a residential care building, sprinklers are required throughout the building and in any fire compartment containing a Class 9a part used for residential care.\n(2) In a Class 9a building, other than as described in (1), sprinklers are required if the building has more than one storey.\n(3)  In a Class 9c building, sprinklers are required throughout the building and in any fire compartment containing a Class 9c part.","st":"NT","base":"E1D10","g":"/ncc/nt-e1d10"},{"c":"NT F4D4","t":"Facilities in Class 3 to 9 buildings","p":"NT Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/6-northern-territory/nt-f4-sanitary-and-other-facilities#_61df58a9-d798-4234-ba14-84c5e99a66a0","x":"Delete clause F4D4 and insert NT F4D4 as follows:\n(1) Except where permitted by (3), (4), (7), F4D5(a), F4D5(b) and F4D12(1), separate sanitary facilities for males and females must be provided for Class 3, 5, 6, 7, 8 or 9 buildings in accordance with Tables F4D4a, F4D4b, F4D4c, F4D4d, F4D4e, F4D4f, F4D4g, F4D4h, F4D4i, F4D4j, F4D4k and F4D4l, as appropriate.\n(2) In Tables F4D4a, F4D4b, F4D4c, F4D4d, F4D4e, F4D4f, F4D4g, F4D4h, F4D4i, F4D4j, F4D4k and F4D4l l—\n‘Number’ means the number of facilities required; and\n‘>’ means greater than; and\na hyphen means no data (refer to the row above for the highest value applicable); and\n‘N/A’ means not applicable; and\na reference to—\n‘employees’ includes owners and managers using the building; and\n‘add 1 per 100 or 150, 250, 500, etc.’ includes any part thereof of that number.\n(3) If not more than 10 people are employed, a unisex facility may be provided instead of separate facilities for each sex.\n(4) If the majority of employees are of one sex, not more than 2 employees of the other sex may share toilet facilities if the facilities are separated by means of walls, partitions and doors to afford privacy.\n(5) Employees and the public may share the same facilities in a Class 6 and 9b building (other than a school or early childhood centre) provided the number of facilities provided is not less than the total number of facilities required for employees plus those required for the public.\n(6) Separate sanitary facilities for males and females need not be provided for patients in a ward area of a Class 9a building.\n(7) A Class 9a health-care building must be provided with\nOne kitchen or other adequate facility for the preparation and cooking or reheating of food including a kitchen sink and washbasin; and\nLaundry facilities for the cleaning and drying of linen and clothing or adequate facilities for holding and dispatch or treatment of soiled linen and clothing, sanitary products and the like and the receipt of clean linen; and\nOn shower for each 8 patients or part thereof; and\nOne island-type plunge bath in each storey containing a ward area.\n(8) A Class 9b early childhood centre must be provided with—\nA kitchen or food preparation area with a kitchen sink, separate hand washing facilities, space for a refrigerator and space for cooking facilities, with\nthe facilities protected by a door or gate with child proof latches to prevent unsupervised access to the facilities by children younger than 5 years old; and\nthe ability to facilitate supervision of children from the facilities if the early childhood centre accommodates children younger than 2 years old.","st":"NT","base":"F4D4","g":"/ncc/nt-f4d4"},{"c":"NT F7P1","t":"Sound transmission through floors","p":"NT Part F7 Sound transmission and insulation","u":"/editions/ncc-2025/adopted/volume-one/6-northern-territory/nt-f7-sound-transmission-and-insulation#_348eed3f-9c88-4f40-8a34-d6f3f765240f","x":"Insert NT clause F7P1 in clause F7P1 as follows:\nFloors separating sole-occupancy units or a sole-occupancy unit from a plant room, lift shaft, stairway, public corridor must provide insulation against the transmission of airborne and impact generated sound sufficient to prevent illness or loss of amenity to the occupants.\nApplications\nNT F7P1 only applies to a Class 2 or 3 building or a Class 9c building.","st":"NT","base":"F7P1","g":"/ncc/nt-f7p1"},{"c":"NT F7P2","t":"Sound transmission through walls","p":"NT Part F7 Sound transmission and insulation","u":"/editions/ncc-2025/adopted/volume-one/6-northern-territory/nt-f7-sound-transmission-and-insulation#_e09b0164-96e2-4735-ba4b-5d2e52326695","x":"Insert NT clause F7P2 in clause F7P2 as follows:\nWalls separating—\nsole-occupancy units; or\na sole-occupancy unit from a plant room, lift shaft, stairway, public corridor, public lobby or the like,\nmust provide sufficient insulation against the transmission or airborne or impact generated sound sufficient to prevent illness or loss of amenity to the occupants.\nApplications\nNT F7P2 only applies to a Class 2 or 3 building.","st":"NT","base":"F7P2","g":"/ncc/nt-f7p2"},{"c":"NT F7P3","t":"Sound transmission through wall and floor penetrations","p":"NT Part F7 Sound transmission and insulation","u":"/editions/ncc-2025/adopted/volume-one/6-northern-territory/nt-f7-sound-transmission-and-insulation#_01510bea-1a5f-41bb-8ee8-a33d150ae484","x":"Insert NT clause F7P3 in clause F7P3 as follows:\nThe required sound insulation of floors and walls must not be compromised by the incorporation or penetration of a pipe or other service element.\nApplications\nNT F7P3 only applies to a Class 2 or 3 building or a Class 9c building.","st":"NT","base":"F7P3","g":"/ncc/nt-f7p3"},{"c":"NT F7P4","t":"Sound transmission through walls in residential care buildings","p":"NT Part F7 Sound transmission and insulation","u":"/editions/ncc-2025/adopted/volume-one/6-northern-territory/nt-f7-sound-transmission-and-insulation#_5896121a-d4d6-4f13-a1ca-bf34bef02a0f","x":"Insert NT clause F7P4 in clause F7P4 as follows:\n(1) Walls separating—\nsole-occupancy units; or\na sole-occupancy unit from a kitchen, bathroom, sanitary compartment (not being an associated ensuite), laundry, plant room or utilities room,\nmust provide insulation against the transmission of airborne sound sufficient to prevent illness or loss of amenity to the occupants.\n(2) Wall separating a sole-occupancy unit from a kitchen or laundry, must provide insulation against the transmission of impact generated sound sufficient to prevent illness or loss of amenity to the occupants.\nApplications\nNT F7P4 only applies to a Class 9c building.","st":"NT","base":"F7P4","g":"/ncc/nt-f7p4"},{"c":"NT F7D1","t":"Deemed-to-Satisfy Provisions","p":"NT Part F7 Sound transmission and insulation","u":"/editions/ncc-2025/adopted/volume-one/6-northern-territory/nt-f7-sound-transmission-and-insulation#_8b811214-1a57-487c-90e0-def5f16c4fd2","x":"Insert NT clause F7D1 in clause F7D1 as follows:\n(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements F7P1 to F7P4 are satisfied by complying with NT F7D2 to NT F7D9.\n(2) Where a Performance Solution is proposed, the relevant Performance Requirements must be determined in accordance with A2G2(3) and A2G4(3) as applicable.","st":"NT","base":"F7D1","g":"/ncc/nt-f7d1"},{"c":"NT F7D2","t":"Application of Part","p":"NT Part F7 Sound transmission and insulation","u":"/editions/ncc-2025/adopted/volume-one/6-northern-territory/nt-f7-sound-transmission-and-insulation#_2743ae12-0e7b-469f-a521-3f501a9cfa97","x":"Insert NT clause F7D2 in clause F7D2 as follows:\nThe Deemed-to-Satisfy Provisions of this Part apply to Class 2 and 3 buildings and Class 9c aged care buildings.","st":"NT","base":"F7D2","g":"/ncc/nt-f7d2"},{"c":"NT F7D3","t":"Weighted sound reduction index: interpretation","p":"NT Part F7 Sound transmission and insulation","u":"/editions/ncc-2025/adopted/volume-one/6-northern-territory/nt-f7-sound-transmission-and-insulation#_f6bdcba8-108b-495e-9ae6-05becbc311de","x":"Insert NT clause F7D3 in clause F7D3 as follows:\nA form of construction required to have a certain weighted sound reduction index (RW) must—\nhave the required value determined under AS ISO 717.1; or\ncomply with NT Specification 28.","st":"NT","base":"F7D3","g":"/ncc/nt-f7d3"},{"c":"NT F7D4","t":"Sound insulation of floors between units","p":"NT Part F7 Sound transmission and insulation","u":"/editions/ncc-2025/adopted/volume-one/6-northern-territory/nt-f7-sound-transmission-and-insulation#_bbaf55de-ccc8-4003-8c0a-fef7a9e912d4","x":"Insert NT clause F7D4 in clause F7D4 as follows:\nA floor separating sole-occupancy units must have an RW not less than 45.","st":"NT","base":"F7D4","g":"/ncc/nt-f7d4"},{"c":"NT F7D5","t":"Sound insulation of walls between units","p":"NT Part F7 Sound transmission and insulation","u":"/editions/ncc-2025/adopted/volume-one/6-northern-territory/nt-f7-sound-transmission-and-insulation#_bedb89b8-a056-4e39-851d-1039c2fcf57d","x":"Insert NT clause F7D5 in clause F7D5 as follows:\nA wall must have an RW not less than 45 if it separates—\nsole-occupancy units; or\na sole-occupancy unit not within a Class 9c building from a plant room, lift shaft, stairway, public corridor, hallway or the like; or\na sole-occupancy unit in a Class 9c building from a kitchen, bathroom, sanitary compartment (not being an associated ensuite), laundry, plant room or utilities room.","st":"NT","base":"F7D5","g":"/ncc/nt-f7d5"},{"c":"NT F7D6","t":"Walls between a bathroom, sanitary compartment, laundry or kitchen and a habitable room in adjoining unit","p":"NT Part F7 Sound transmission and insulation","u":"/editions/ncc-2025/adopted/volume-one/6-northern-territory/nt-f7-sound-transmission-and-insulation#_b80cd032-000d-43a2-a54a-944e4666ce1b","x":"Insert NT clause F7D6 in clause F7D6 as follows:\n(1) Except for a Class 9c building, a wall separating a bathroom, sanitary compartment, laundry or kitchen in one sole-occupancy unit from a habitable room (other than a kitchen) in an adjoining unit must—\nhave an RW of not less than 50; and\nprovide satisfactory insulation against impact sound; and\nnot incorporate a duct which reduces the RW of the wall to less than 50.\n(2) A wall satisfies (1)(a) and (b) if it is—\nin accordance with (3); or\nfor other than masonry, in 2 or more separate leaves without rigid mechanical connection except at their periphery; or\nidentical to a prototype that is no less resistant to the transmission of impact sound when tested in accordance with NT Specification 29 than a wall listed in (3).\n(3) For the purposes of (2)(a) and (c), the construction of walls to reduce the transmission of impact sound must be as follows:\nCavity brickwork: two leaves of 90 mm brick masonry with—\nall joints filled solid with mortar; and\nan air space not less than 40 mm between the leaves; and\nthe leaves connected only by ties in accordance with AS 3700.\nSingle leaf brickwork: 110 mm thick brick masonry with—\neach face rendered 13 mm thick; and\n50 mm x 12 mm thick timber battens at not more than 610 mm centres fixed to each face but not recessed into the render; and\none layer of 12 mm thick softboard nailed to the battens; and\n6 mm thick medium density hardboard adhesive-fixed to the softboard.\nConcrete blockwork: 190 mm thick concrete block masonry with—\neach face of the blocks fitted with 50 mm x 50 mm timber battens, spaced at not more than 610 mm centres, screw-fixed into resilient plugs with rubber inserts; and\nthe space between the battens completely filled with mineral or glass wool blanket or batts not less than 50 mm thick; and\nthe outer face of the battens finished with plasterboard not less than 10 mm thick or other material with a mass per unit area not less than 7.3 kg/m2.","st":"NT","base":"F7D6","g":"/ncc/nt-f7d6"},{"c":"NT F7D7","t":"Soil and waste pipes to be separated","p":"NT Part F7 Sound transmission and insulation","u":"/editions/ncc-2025/adopted/volume-one/6-northern-territory/nt-f7-sound-transmission-and-insulation#_1c0ca0ac-3ea9-4ab3-a36e-9502c792cd5b","x":"Insert NT clause F7D7 in clause F7D7 as follows:\nIf a soil or waste pipe, including a pipe that is embedded in or passes through a floor, serves or passes through more than one sole-occupancy unit —\nthe pipe must be separated from the rooms of any sole-occupancy unit by construction with an RW not less than—\n45 if the adjacent room is a habitable room (other than a kitchen); or\n30 if the adjacent room is a kitchen or any other room; and\na door or panel provided access to the pipe must not open into any habitable room (other than a kitchen); and\nan access door or panel in any other part must be firmly fixed so as to overlap the frame or rebate of the frame by not less than 10 mm, be fitted with a sealing gasket along all edges and be constructed of—\nwood, particleboard or blockboard not less than 38 mm thick; or\ncompressed fibre reinforced cement sheeting not less than 9 mm thick; or\nother suitable material with a mass per unit area not less than 24.4 kg/m2.","st":"NT","base":"F7D7","g":"/ncc/nt-f7d7"},{"c":"NT F7D8","t":"Isolation of pumps","p":"NT Part F7 Sound transmission and insulation","u":"/editions/ncc-2025/adopted/volume-one/6-northern-territory/nt-f7-sound-transmission-and-insulation#_1ae22037-6dc0-4639-9914-a6f8576cdeff","x":"Insert NT clause F7D8 in clause F7D8 as follows:\nA flexible coupling must be used at the point of connection between the service pipes in a building and any circulating or other pump.","st":"NT","base":"F7D8","g":"/ncc/nt-f7d8"},{"c":"NT F7D9","t":"Walls between a bedroom and kitchen or laundry in a Class 9c building","p":"NT Part F7 Sound transmission and insulation","u":"/editions/ncc-2025/adopted/volume-one/6-northern-territory/nt-f7-sound-transmission-and-insulation#_2aea5fdc-79c3-4e0e-85b7-d45d17aead31","x":"Insert NT clause F7D9 in clause F7D9 as follows:\nIn addition to NT F7D5, a wall separating a sole-occupancy unit in a Class 9c building from a kitchen or laundry must—\nfor other than masonry, be two or more separate leaves without rigid mechanical connection except at their periphery; or\nbe identical with a prototype that is no less resistant to the transmission of impact sound when tested in accordance with NT Specification 29 than a wall listed in NT S28C3.","st":"NT","base":"F7D9","g":"/ncc/nt-f7d9"},{"c":"NT G1P1","t":"Swimming pool drainage","p":"NT Part G1 Minor structures and components","u":"/editions/ncc-2025/adopted/volume-one/6-northern-territory/nt-g1-minor-structures-and-components#_id15004","x":"This clause has deliberately been left blank.","st":"NT","base":"G1P1","g":"/ncc/nt-g1p1"},{"c":"NT G1P2","t":"Swimming pool access and water recirculation systems","p":"NT Part G1 Minor structures and components","u":"/editions/ncc-2025/adopted/volume-one/6-northern-territory/nt-g1-minor-structures-and-components#_6cab0512-ad83-47b4-9273-9325888d7f53","x":"Delete clause G1P2 and insert NT G1P2 as follows:\nA swimming pool water recirculation system must incorporate safety measures to avoid entrapment of, or injury to, a person.\nApplications\nNT G1P2 only applies to a swimming pool with a depth of water more than 300 mm.","st":"NT","base":"G1P2","g":"/ncc/nt-g1p2"},{"c":"NT G1D2","t":"Swimming pools","p":"NT Part G1 Minor structures and components","u":"/editions/ncc-2025/adopted/volume-one/6-northern-territory/nt-g1-minor-structures-and-components#_id15223","x":"This clause has deliberately been left blank.\nBarriers and fences for swimming pools are regulated by the Northern Territory of Australia Swimming Pool Safety Act 2004.","st":"NT","base":"G1D2","g":"/ncc/nt-g1d2"},{"c":"NT G1D5","t":"Swimming pool drainage","p":"NT Part G1 Minor structures and components","u":"/editions/ncc-2025/adopted/volume-one/6-northern-territory/nt-g1-minor-structures-and-components#_id15284","x":"This clause has deliberately been left blank.","st":"NT","base":"G1D5","g":"/ncc/nt-g1d5"},{"c":"NT Part J1","t":"Energy efficiency performance requirements","p":"NT Part J1 Energy efficiency performance requirements","u":"/editions/ncc-2025/adopted/volume-one/6-northern-territory/nt-j1-energy-efficiency-performance-requirements","x":"This Part has deliberately been left blank. For a Class 2 building and Class 4 part of a building, Section J is replaced with Section J of BCA 2009 (without NT variation). For Class 3 and Class 5-9 buildings, Section J of NCC 2025 does not apply and is replaced with Section J of NCC 2019 (without NT variation).","st":"NT","base":"Part J1","g":"/ncc/nt-part-j1"},{"c":"NT Part J2","t":"Energy efficiency","p":"NT Part J2 Energy efficiency","u":"/editions/ncc-2025/adopted/volume-one/6-northern-territory/nt-j2-energy-efficiency","x":"This Part has deliberately been left blank. For a Class 2 building and Class 4 part of a building, Section J is replaced with Section J of BCA 2009 (without NT variation). For Class 3 and Class 5-9 buildings, Section J of NCC 2025 does not apply and is replaced with Section J of NCC 2019 (without NT variation).","st":"NT","base":"Part J2","g":"/ncc/nt-part-j2"},{"c":"NT Part J3","t":"Elemental provisions for a Class 4 part of a building","p":"NT Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/6-northern-territory/nt-j3-elemental-provisions-class-4-part-building","x":"This Part has deliberately been left blank. For a Class 2 building and Class 4 part of a building, Section J is replaced with Section J of BCA 2009 (without NT variation). For Class 3 and Class 5-9 buildings, Section J of NCC 2025 does not apply and is replaced with Section J of NCC 2019 (without NT variation).","st":"NT","base":"Part J3","g":"/ncc/nt-part-j3"},{"c":"NT Part J4","t":"Building fabric","p":"NT Part J4 Building fabric","u":"/editions/ncc-2025/adopted/volume-one/6-northern-territory/nt-j4-building-fabric","x":"This Part has deliberately been left blank. For a Class 2 building and Class 4 part of a building, Section J is replaced with Section J of BCA 2009 (without NT variation). For Class 3 and Class 5-9 buildings, Section J of NCC 2025 does not apply and is replaced with Section J of NCC 2019 (without NT variation).","st":"NT","base":"Part J4","g":"/ncc/nt-part-j4"},{"c":"NT Part J5","t":"Building sealing","p":"NT Part J5 Building sealing","u":"/editions/ncc-2025/adopted/volume-one/6-northern-territory/nt-j5-building-sealing","x":"This Part has deliberately been left blank. For a Class 2 building and Class 4 part of a building, Section J is replaced with Section J of BCA 2009 (without NT variation). For Class 3 and Class 5-9 buildings, Section J of NCC 2025 does not apply and from is replaced with Section J of NCC 2019 (without NT variation).","st":"NT","base":"Part J5","g":"/ncc/nt-part-j5"},{"c":"NT Part J6","t":"Air-conditioning and ventilation","p":"NT Part J6 Air-conditioning and ventilation","u":"/editions/ncc-2025/adopted/volume-one/6-northern-territory/nt-j6-air-conditioning-and-ventilation","x":"This Part has deliberately been left blank. For a Class 2 building and Class 4 part of a building, Section J is replaced with Section J of BCA 2009 (without NT variation). For Class 3 and Class 5-9 buildings, Section J of NCC 2025 does not apply and is replaced with Section J of NCC 2019 (without NT variation).","st":"NT","base":"Part J6","g":"/ncc/nt-part-j6"},{"c":"NT Part J7","t":"Artificial lighting and power","p":"NT Part J7 Artificial lighting and power","u":"/editions/ncc-2025/adopted/volume-one/6-northern-territory/nt-j7-artificial-lighting-and-power","x":"This Part has deliberately been left blank. For a Class 2 building and Class 4 part of a building, Section J is replaced with Section J of BCA 2009 (without NT variation). For Class 3 and Class 5-9 buildings, Section J of NCC 2025 does not apply and is replaced with Section J of NCC 2019 (without NT variation).","st":"NT","base":"Part J7","g":"/ncc/nt-part-j7"},{"c":"NT Part J8","t":"Heated water supply and swimming pool and spa pool plant","p":"NT Part J8 Heated water supply and swimming pool and spa pool plant","u":"/editions/ncc-2025/adopted/volume-one/6-northern-territory/nt-j8-heated-water-supply-and-swimming-pool-and-spa-pool-plant","x":"This Part has deliberately been left blank. For a Class 2 building and Class 4 part of a building, Section J is replaced with Section J of BCA 2009 (without NT variation). For Class 3 and Class 5-9 buildings, Section J of NCC 2025 does not apply and is replaced with Section J of NCC 2019 (without NT variation).","st":"NT","base":"Part J8","g":"/ncc/nt-part-j8"},{"c":"NT Part J9","t":"Energy monitoring and on-site distributed energy resources","p":"NT Part J9 Energy monitoring and on-site distributed energy resources","u":"/editions/ncc-2025/adopted/volume-one/6-northern-territory/nt-j9-energy-monitoring-and-site-distributed-energy-resources","x":"This Part has deliberately been left blank. For a Class 2 building and Class 4 part of a building, Section J is replaced with Section J of BCA 2009 (without NT variation). For Class 3 and Class 5-9 buildings, Section J of NCC 2025 does not apply and is replaced with Section J of NCC 2019 (without NT variation).","st":"NT","base":"Part J9","g":"/ncc/nt-part-j9"},{"c":"QLD B1P3","t":"Buildings in flood areas","p":"QLD Part B1 Structural provisions","u":"/editions/ncc-2025/adopted/volume-one/7-queensland/qld-b1-structural-provisions#_id5819","x":"This clause has deliberately been left blank.\nBuilding work in designated flood areas is regulated by the Building Act 1975 (QLD) and the Queensland Development Code MP 3.5 - Construction of buildings in flood hazard areas.","st":"QLD","base":"B1P3","g":"/ncc/qld-b1p3"},{"c":"QLD B1D4","t":"Determination of structural resistance of materials and forms of construction","p":"QLD Part B1 Structural provisions","u":"/editions/ncc-2025/adopted/volume-one/7-queensland/qld-b1-structural-provisions#_6c4c959b-439d-4d0d-87ce-a473ec5ee7c4","x":"Delete clause B1D4 and insert QLD B1D4 as follows:\nThe structural resistance of materials and forms of construction must be determined in accordance with the following, as appropriate:\nMasonry (including masonry-veneer, unreinforced masonry and reinforced masonry): AS 3700, except—\n‘(for piers—isolated or engaged)’ is removed from Clause 8.5.1(d); and\nwhere Clause 8.5.1 requires design as for unreinforced masonry in accordance with Section 7, the member must also be designed as unreinforced masonry in accordance with Tables 10.3 and 4.1(a)(i)(C) of AS 3700.\nConcrete:\nConcrete construction (including reinforced and prestressed concrete): AS 3600.\nAutoclaved aerated concrete: AS 5146.1.\nPost-installed and cast-in fastenings: AS 5216.\nSteel construction:\nSteel structures: AS 4100.\nCold-formed steel structures: AS/NZS 4600.\nResidential and low-rise steel framing: NASH Standard – Residential and Low-Rise Steel Framing Part 1 or Part 2.\nComposite steel and concrete: AS/NZS 2327.\nAluminium construction: AS/NZS 1664.1 or AS/NZS 1664.2.\nTimber construction:\nDesign of timber structures: AS 1720.1.\nTimber structures: AS 1684.2, AS 1684.3 or AS 1684.4.\nNailplated timber roof trusses: AS 1720.5.\nTimber used for structural purposes: a species scheduled for the appropriate use in Schedules A, B or C of Book 2 of the ‘Queensland Government, Department of Agriculture, Fisheries and Forestry - Construction timbers in Queensland, Book 1 and Book 2 - Properties and specifications for satisfactory performance of construction timbers in Queensland - Class 1 and 10 buildings (Houses, carports, garages, greenhouses and sheds)’.\nPiling: AS 2159.\nGlazed assemblies:\nThe following glazed assemblies in an external wall must comply with AS 2047:\nWindows excluding those listed in (ii).\nSliding and swinging glazed doors with a frame, including french and bi-fold doors with a frame.\nAdjustable louvres.\nShopfronts.\nWindow walls with one piece framing.\nAll glazed assemblies not covered by (i) and the following glazed assemblies must comply with AS 1288:\nAll glazed assemblies not in an external wall.\nRevolving doors.\nFixed louvres.\nSkylights, roof lights and windows in other than the vertical plane.\nSliding and swinging doors without a frame.\nWindows constructed on site and architectural one-off windows, which are not design tested in accordance with AS 2047.\nSecond-hand windows, re-used windows and recycled windows.\nHeritage windows.\nGlazing used in balustrades and sloping overhead glazing.\nTermite Risk Management: Where a primary building element is subject to attack by subterranean termites: AS 3660.1, and—\nfor the purposes of this provision, a primary building element consisting entirely of, or a combination of, any of the following materials is considered not subject to termite attack:\nSteel, aluminium or other metals.\nConcrete.\nMasonry.\nFibre-reinforced cement.\nTimber — naturally termite resistant in accordance with Appendix C of AS 3660.1.\nTimber — preservative treated in accordance with Appendix D of AS 3660.1; and\na durable notice must be permanently fixed to the building in a prominent location, such as a meter box or the like, indicating—\nthe termite management system used; and\nthe date of installation of the system; and\nwhere a chemical is used, its life expectancy as listed on the appropriate authority’s pesticides register label; and\nthe installer’s or manufacturer’s recommendations for the scope and frequency of future inspections for termite activity.\nRoof construction (except in cyclonic areas):\nRoof tiling: AS 2050.\nCellulose cement corrugated sheets: AS/NZS 2908.1 with safety mesh installed in accordance with AS/NZS 1562.3 clause 2.4.3.2 except for sub-clause (g) for plastic sheeting.\nMetal roofing: AS 1562.1.\nRoof construction (cyclonic areas) — metal roofing AS 1562.1 and Specification 4.\nParticleboard structural flooring: AS 1860.2.\nGarage doors and other large access doors in openings not more than 3 m in height in external walls of buildings determined as being located in wind region C or D in accordance with AS/NZS 1170.2: AS/NZS 4505.\nLift shafts which are not required to have an FRL, must—\nexcept as required by (ii), be completely enclosed with non-perforated material between the bottom of the pit and the ceiling of the lift shaft, other than—\nat landing doors, emergency doors and pit access doors; and\nlow-rise, low-speed constant pressure lifts.\nin atrium and observation areas, be protected with non-perforated material not less than 2.5 m in height—\nabove any places on which a person can stand, which are within 800 mm horizontal reach of any vertical moving lift component including ropes and counterweights; and\nat the lowest level of the atrium area that the lift serves, on all sides except the door opening, for not less than 2.5 m in height, by enclosure with non-perforated material; and\nbe of non-brittle material; and\nwhere glazing is used—\ncomply with Table B1D4; or\nnot fail the deflection criteria required by S6C11(c)(iii).\nInsert QLD table (B1D4) B1D4 as follows:\nQLD Table B1D4: Material and minimum thickness of glazing and polycarbonate sheet\nApplication\nLift shaft vision panels more than 65,000 mm2, door panels, and lift shafts\nLift shaft vision panels less than or equal to 65,000 mm2\nLaminated glass\n10 mm (0.76 mm interlayer)\n6 mm (0.76 mm interlayer)\nToughened/laminated glass\n10 mm (0.76 mm interlayer)\n6 mm (0.76 mm interlayer)\nAnnealed glass with security polyester film coating\n10 mm\n6 mm\nSafety wire glass\nNot applicable\nSubject to fire test\nPolycarbonate sheet\n13 mm\n6 mm","st":"QLD","base":"B1D4","g":"/ncc/qld-b1d4"},{"c":"QLD B1D6","t":"Construction of buildings in flood hazard areas","p":"QLD Part B1 Structural provisions","u":"/editions/ncc-2025/adopted/volume-one/7-queensland/qld-b1-structural-provisions#_id6138","x":"This clause has deliberately been left blank.\nBuilding work in designated flood hazard areas is regulated by the Building Act 1975 (QLD), and the Queensland Development Code MP 3.5 - Construction of buildings in flood hazard areas.","st":"QLD","base":"B1D6","g":"/ncc/qld-b1d6"},{"c":"QLD G1P2","t":"Swimming pool access and water recirculation systems","p":"QLD Part G1 Minor structures and components","u":"/editions/ncc-2025/adopted/volume-one/7-queensland/qld-g1-minor-structures-and-components#_05fccab2-13d2-4a41-8b6d-e30c0e0230a5","x":"Delete clause G1P2 and insert QLD G1P2 as follows:\n(1) Barriers and fences for swimming pools are regulated by the Building Act 1975 (QLD), Building Regulation 2021 (QLD) and the Queensland Development Code MP 3.4 — Swimming pool barriers.\n(2) A swimming pool water recirculation system must incorporate safety measures to avoid entrapment of, or injury to a person.\nApplications\nQLD G1P2 only applies to a swimming pool with a depth of water more than 300 mm. Barriers and fences for swimming pools are regulated by the Building Act 1975 (QLD), Building Regulation 2021 (QLD) and the Queensland Development Code MP 3.4 — Swimming pool barriers.","st":"QLD","base":"G1P2","g":"/ncc/qld-g1p2"},{"c":"QLD G1D2","t":"Swimming pools","p":"QLD Part G1 Minor structures and components","u":"/editions/ncc-2025/adopted/volume-one/7-queensland/qld-g1-minor-structures-and-components#_id15222","x":"This clause has deliberately been left blank.\nBarriers and fences for swimming pools are regulated by the Building Act 1975 (QLD), Building Regulation 2021 (QLD) and the Queensland Development Code MP 3.4 - Swimming pool barriers.","st":"QLD","base":"G1D2","g":"/ncc/qld-g1d2"},{"c":"QLD G5P1","t":"Bushfire resistance","p":"QLD Part G5 Construction in bushfire prone areas","u":"/editions/ncc-2025/adopted/volume-one/7-queensland/qld-g5-construction-bushfire-prone-areas#_dcdcb3cb-4721-497e-9917-62c819bbf7c4","x":"Delete clause G5P1 and insert QLD G5P1 as follows:\nA building that is constructed in a designated bushfire prone area must be designed and constructed to—\nreduce the risk of ignition from a design bushfire with an annual exceedance probability not more than 1:100 years, or 1:200 years for a Class 9 building; and\ntake account of the assessed duration and intensity of the fire actions of the design bushfire; and\nbe designed to prevent internal ignition of the building and its contents; and\nmaintain the structural integrity of the building for the duration of the design bushfire.\nApplications\nG5P1 applies in a designated bushfire prone area to—\na Class 2 or 3 building; and\na Class 9a health-care building; and\na Class 9b—\nearly childhood centre; and\nprimary or secondary school; and\na Class 9c residential care building; and\na Class 10a building or deck immediately adjacent or connected to a building of a type listed in (a) to (d)\nbut does not apply when the classified vegetation is Group F rainforest (excluding wet sclerophyll forest types), mangrove communities and grasslands under 300 mm high.","st":"QLD","base":"G5P1","g":"/ncc/qld-g5p1"},{"c":"QLD G5D2","t":"Application of Part","p":"QLD Part G5 Construction in bushfire prone areas","u":"/editions/ncc-2025/adopted/volume-one/7-queensland/qld-g5-construction-bushfire-prone-areas#_ce66b17f-9ef7-44c0-9e10-f54557ea9660","x":"Delete clause G5D2 and insert QLD G5D2 as follows:\n(1) The Deemed-to-Satisfy Provisions of this Part apply in a designated bushfire prone area to—\na Class 2 or 3 building; or\na Class 9a health-care building; or\na Class 9b—\nan early childhood centre; or\na primary or secondary school; or\na Class 9c residential care building; or\na Class 10a building or deck associated with a building of a type listed in (a) to (d).\n(2) The Deemed-to-Satisfy Provisions of this Part do not apply when the classified vegetation is Group F rainforest (excluding wet sclerophyll forest types), mangrove communities and grasslands under 300 mm high.","st":"QLD","base":"G5D2","g":"/ncc/qld-g5d2"},{"c":"QLD J6D10","t":"Space heating","p":"QLD Part J6 Air-conditioning and ventilation","u":"/editions/ncc-2025/adopted/volume-one/7-queensland/qld-j6-air-conditioning-and-ventilation#_a2ad256e-9cbc-4bfc-818f-84f815b7baff","x":"Delete subclause J6D10(5) and insert QLD J6D10(5) as follows:\n(5) This sub-clause has deliberately been left blank.\nDelete subclause J6D10(6) and insert QLD J6D10(6) as follows:\n(6) This sub-clause has deliberately been left blank.\nDelete subclause J6D10(7) and insert QLD J6D10(7) as follows:\n(7) This sub-clause has deliberately been left blank.","st":"QLD","base":"J6D10","g":"/ncc/qld-j6d10"},{"c":"QLD J8D3","t":"Heated water supply","p":"QLD Part J8 Heated water supply and swimming pool and spa pool plant","u":"/editions/ncc-2025/adopted/volume-one/7-queensland/qld-j8-heated-water-supply-and-swimming-pool-and-spa-pool-plant#_8813fe9b-68b3-4666-bff9-21d92af198e6","x":"Delete subclause J8D3(3) and insert QLD J8D3(3) as follows:\n(3) This sub-clause has deliberately been left blank.\nDelete subclause J8D3(4) and insert QLD J8D3(4) as follows:\n(4) This sub-clause has deliberately been left blank.","st":"QLD","base":"J8D3","g":"/ncc/qld-j8d3"},{"c":"QLD J8D4","t":"Swimming pool heating and pumping","p":"QLD Part J8 Heated water supply and swimming pool and spa pool plant","u":"/editions/ncc-2025/adopted/volume-one/7-queensland/qld-j8-heated-water-supply-and-swimming-pool-and-spa-pool-plant#_8ba59679-c93c-4754-a003-f3a710892daa","x":"Delete subclause J8D4(6) and insert QLD J8D4(6) as follows:\n(6) This sub-clause has deliberately been left blank.\nDelete subclause J8D4(7) and insert QLD J8D4(7) as follows:\n(7) This sub-clause has deliberately been left blank.","st":"QLD","base":"J8D4","g":"/ncc/qld-j8d4"},{"c":"QLD J8D5","t":"Spa pool heating and pumping","p":"QLD Part J8 Heated water supply and swimming pool and spa pool plant","u":"/editions/ncc-2025/adopted/volume-one/7-queensland/qld-j8-heated-water-supply-and-swimming-pool-and-spa-pool-plant#_e8e53f4d-74a2-4a1e-a17d-71b29beb6a7b","x":"Delete subclause J8D5(6) and insert QLD J8D5(6) as follows:\n(6) This sub-clause has deliberately been left blank.\nDelete subclause J8D5(7) and insert QLD J8D5(7) as follows:\n(7) This sub-clause has deliberately been left blank.","st":"QLD","base":"J8D5","g":"/ncc/qld-j8d5"},{"c":"SA A6G7","t":"Class 6 buildings","p":"SA Part A6 Building classification","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-a6-building-classification#_426d375b-b2f2-452a-a372-c072e6a8e0c5","x":"Delete clause A6G7 and insert SA A6G7 as follows:\nA Class 6 building is a shop or other building for the sale of goods by retail or the supply of services direct to the public, including—\nan eating room, cafe, restaurant, milk or soft drink bar; or\na dining room, bar, shop or kiosk part of a hotel or motel; or\na hairdresser’s or barber’s shop, public laundry, or undertaker’s establishment; or\nmarket or sale room, showroom, or service station; or\na small arts venue.","st":"SA","base":"A6G7","g":"/ncc/sa-a6g7"},{"c":"SA B1P3","t":"Buildings in flood areas","p":"SA Part B1 Structural provisions","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-b1-structural-provisions#_id5818","x":"This clause has deliberately been left blank.","st":"SA","base":"B1P3","g":"/ncc/sa-b1p3"},{"c":"SA B1D6","t":"Construction of buildings in flood hazard areas","p":"SA Part B1 Structural provisions","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-b1-structural-provisions#_id6125","x":"This clause has deliberately been left blank.","st":"SA","base":"B1D6","g":"/ncc/sa-b1d6"},{"c":"SA C2D1","t":"Deemed-to-Satisfy Provisions","p":"SA Part C2 Fire resistance and stability","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-c2-fire-resistance-and-stability#_125ff9f9-7566-420b-80b0-c1be76b44420","x":"Delete subclause C2D1(1) and insert SA C2D1(1) as follows:\n(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements C1P1 to C1P9 are satisfied by complying with—\nC2D2 to C2D15, C3D2 to C3D15, SA C3D16 and C4D2 to C4D17; and\nin a building containing an atrium, Part G3; and\nfor a building containing an occupiable outdoor area, Part G6; and\nfor additional requirements for Class 9b buildings, Part I1; and\nfor bulk grain storage facilities, Part SA I4.","st":"SA","base":"C2D1","g":"/ncc/sa-c2d1"},{"c":"SA C2D2","t":"Type of construction required","p":"SA Part C2 Fire resistance and stability","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-c2-fire-resistance-and-stability#_288764fb-99f1-4ce0-a824-c432b23fc35c","x":"Delete subclause C2D2(1) and insert SA C2D2(1) as follows:\n(1) The minimum Type of fire-resisting construction of a building must be determined in accordance with Table C2D2, except as allowed for—\ncertain Class 2, 3 or 9c buildings, in C2D6; and\na Class 4 part of a building located on the top storey, in C2D4(2); and\nopen spectator stands and indoor sports stadiums, in C2D8; and\nClass 2 buildings located within 3 m of a brush fence and Class 10b brush fences located within 3 m of a Class 2 building, in SA C2D2(3) and (4).\nInsert SA subclause C2D2(3) in clause C2D2 as follows:\n(3) In addition to the minimum fire-resisting construction requirements of Table C2D2 and Specification 5 a Class 2 building must not be constructed within 3 m of a Class 10b brush fence unless any part of the building within 3 m of the brush fence complies with the fire-resisting requirements of SA C3D16.\nInsert SA subclause C2D2(4) in clause C2D2 as follows:\n(4) A Class 10b brush fence must not be constructed within 3 m of a Class 2 building unless any part of the building within 3 m of the brush fence complies with the fire-resisting construction requirements of SA C3D16.","st":"SA","base":"C2D2","g":"/ncc/sa-c2d2"},{"c":"SA C3D1","t":"Deemed-to-Satisfy Provisions","p":"SA Part C3 Compartmentation and separation","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-c3-compartmentation-and-separation#_c79ff0ff-ea2e-4202-bf67-fd624db3142c","x":"Delete subclause C3D1(1) and insert SA C3D1(1) as follows:\n(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements C1P1 to C1P9 are satisfied by complying with—\nC2D2 to C2D15, C3D2 to C3D15, SA C3D16 and C4D2 to C4D17; and\nin a building containing an atrium, Part G3; and\nfor a building containing an occupiable outdoor area, Part G6; and\nfor additional requirements for Class 9b buildings, Part I1; and\nfor bulk grain storage facilities, Part SA I4.","st":"SA","base":"C3D1","g":"/ncc/sa-c3d1"},{"c":"SA C3D16","t":"Class 2 external walls exposed to brush fences","p":"SA Part C3 Compartmentation and separation","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-c3-compartmentation-and-separation#_c50d751b-d947-49f0-bf37-8c8f22c5da5e","x":"Insert SA clause C3D16 in clause C3D16 as follows:\nWhere the distance between the external wall of a Class 2 building and a brush fence is less than 3 m, the Class 2 building must comply with the following:\nAn external wall or part of an external wall exposed to the brush fence must be fire-resisting and extend to the underside of a non-combustible roof covering or a non-combustible eaves lining or to a point at which exposure to the brush fence no longer exists and must—\nhave a FRL of at least 60/60/60 when tested from the outside; or\nbe of masonry veneer construction in which the external masonry veneer is not less than 90 mm thick; or\nbe of masonry construction not less than 90 mm thick; and\nhave any exposed openings protected in accordance with C4D5.\nWhere an external wall is required by (a) to be fire-resisting, only that part of the wall, including openings within the specified distance, need to be constructed in that manner.\nThe requirements of (a) do not apply to subfloor vents, roof vents, weepholes, control joints, construction joints and penetrations for pipes, conduits and the like.\nThe following are permitted to encroach within 3 m of a brush fence —\nnon-combustible fascias, gutters, downpipes; and\neaves with non-combustible roof cladding and non-combustible lining; and\nflues, chimneys, pipes, domestic fuel tanks, cooling or heating appliances or other services; and\nlight fittings, electricity or gas meters, aerials or antennas; and\npergolas, sun blinds or water tanks; and\nunroofed terraces, landings, steps and ramps, not more than 1 m in height.\nThe distance from any point on an external wall of a building to a brush fence is measured in any direction from the external wall.","st":"SA","base":"C3D16","g":"/ncc/sa-c3d16"},{"c":"SA C4D1","t":"Deemed-to-Satisfy Provisions","p":"SA Part C4 Protection of openings","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-c4-protection-openings#_61d6315c-fa7a-4a1b-b9e7-2da6b8397abb","x":"Delete subclause C4D1(1) and insert SA C4D1(1) as follows:\n(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements C1P1 to C1P9 are satisfied by complying with—\nC2D2 to C2D15, C3D2 to C3D15, SA C3D16 and C4D2 to C4D17; and\nin a building containing an atrium, Part G3; and\nfor a building containing an occupiable outdoor area, Part G6; and\nfor additional requirements for Class 9b buildings, Part I1; and\nfor bulk grain storage facilities, Part SA I4.","st":"SA","base":"C4D1","g":"/ncc/sa-c4d1"},{"c":"SA D2D1","t":"Deemed-to-Satisfy Provisions","p":"SA Part D2 Provision for escape","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-d2-provision-escape#_544e449a-888f-4f07-9565-f4be0dfdf302","x":"Delete subclause D2D1(1) and insert SA D2D1(1) as follows:\n(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements D1P1 to D1P6, D1P8 and D1P10 are satisfied by complying with—\nD2D2 to D2D23, D3D2 to D3D31 and D4D2 to D4D13; and\nin a building containing an atrium, Part G3; and\nin a building in an alpine area, Part G4; and\nfor a building containing an occupiable outdoor area, Part G6; and\nfor additional requirements for Class 9b buildings, Part I1; and\nfor public transport buildings, Part I2; and\nfor farm buildings, Part I3; and\nfor bulk grain storage facilities, SA Part I4.","st":"SA","base":"D2D1","g":"/ncc/sa-d2d1"},{"c":"SA D3D1","t":"Deemed-to-Satisfy Provisions","p":"SA Part D3 Construction of exits","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-d3-construction-exits#_c4c40fd7-897f-41cb-b209-994dfa649b58","x":"Delete subclause D3D1(1) and insert SA D3D1(1) as follows:\n(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements D1P1 to D1P6, D1P8 to D1P10 are satisfied by complying with—\nD2D2 to D2D23, D3D2 to D3D31 and D4D2 to D4D13; and\nin a building containing an atrium, Part G3; and\nin a building in an alpine area, Part G4; and\nfor a building containing an occupiable outdoor area, Part G6; and\nfor additional requirements for Class 9b buildings, Part I1; and\nfor public transport buildings, Part I2; and\nfor farm buildings, Part I3; and\nfor bulk grain storage facilities, SA Part I4.","st":"SA","base":"D3D1","g":"/ncc/sa-d3d1"},{"c":"SA D4D2","t":"General building access requirements","p":"SA Part D4 Access for people with a disability","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-d4-access-people-disability#_cfd19ea2-ed3a-4b7c-af32-86deccf9a362","x":"Delete subclause D4D2(4) and insert SA D4D2(4) as follows:\n(4) For a Class 2 building, access requirements are as follows:\nCommon areas:\nFrom a pedestrian entrance required to be accessible to at least one floor containing sole-occupancy units and to the entrance doorway of each sole-occupancy unit located on that level.\nTo and within not less than one of each type of room or space for use in common by the residents, including a cooking facility, sauna, gymnasium, swimming pool, common laundry, games room, individual shop, eating area, or the like.\nWhere a ramp complying with AS 1428.1 or a passenger lift is installed—\nto the entrance doorway of each sole-occupancy unit; and\nto and within rooms or spaces for use in common by the residents.\nThe requirements of (iii) only apply where the space referred to in (iii)(A) or (iii)(B) is located on the levels served by the lift or ramp.\nIn developments consisting of 20 or more residential sole-occupancy units — to and within one residential sole-occupancy unit or 5% of the total number of residential sole-occupancy units provided, whichever is the greater, must be accessible.","st":"SA","base":"D4D2","g":"/ncc/sa-d4d2"},{"c":"SA D4D5","t":"Exemptions","p":"SA Part D4 Access for people with a disability","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-d4-access-people-disability#_f1f22880-81bc-4efa-886e-b5e79594dcf7","x":"Delete clause D4D5 and insert SA D4D5 as follows:\n The following areas are not required to be accessible:\nAn area where access would be inappropriate because of the particular purpose for which the area is used.\nAn area that would pose a health or safety risk for people with a disability.\nAny path of travel providing access only to an area exempted by (a) or (b).\nAn area in a farm building and a bulk grain storage facility where access would be inappropriate because of the particular purpose for which the area is used.","st":"SA","base":"D4D5","g":"/ncc/sa-d4d5"},{"c":"SA E1D1","t":"Deemed-to-Satisfy Provisions","p":"SA Part E1 Fire fighting equipment","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-e1-fire-fighting-equipment#_c9cf6d30-711d-4280-b8f4-c499950e6e1e","x":"Delete subclause E1D1(1) and insert SA E1D1(1) as follows:\n(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements E1P1 to E1P6 are satisfied by complying with—\nE1D2 to E1D17; and\nin a building containing an atrium, Part G3; and\nin a building in an alpine area, Part G4; and\nfor a building containing an occupiable outdoor area, Part G6; and\nfor additional requirements for Class 9b buildings, Part I1; and\nfor farm buildings, Part I3; and\nfor bulk grain storage facilities, SA Part I4.","st":"SA","base":"E1D1","g":"/ncc/sa-e1d1"},{"c":"SA E2D1","t":"Deemed-to-Satisfy Provisions","p":"SA Part E2 Smoke hazard management","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-e2-smoke-hazard-management#_dbee36b2-af79-4941-9a64-2e8f6cc2e8e0","x":"Delete subclause E2D1(1) and insert SA E2D1(1) as follows:\n(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements E2P1 and E2P2 are satisfied by complying with—\nE2D2 to E2D21; and\nin a building containing an atrium, Part G3; and\nin a building in an alpine area, Part G4; and\nfor additional requirements for Class 9b buildings, Part I1; and\nfor bulk grain storage facilities, SA Part I4.","st":"SA","base":"E2D1","g":"/ncc/sa-e2d1"},{"c":"SA E4D1","t":"Deemed-to-Satisfy Provisions","p":"SA Part E4 Visibility in an emergency, exit signs and warning systems","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-e4-visibility-emergency-exit-signs-and-warning-systems#_b6c74232-8215-4355-a075-eb6fab585611","x":"Delete subclause E4D1(1) and insert SA E4D1(1) as follows:\n(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements E4P1 to E4P3 are satisfied by complying with—\nE4D2 to E4D9; and\nin a building containing an atrium, Part G3; and\nin a building in an alpine area, Part G4; and\nfor a building containing an occupiable outdoor area, Part G6; and\nfor additional requirements for Class 9b buildings, Part I1; and\nfor farm buildings, Part I3; and\nfor bulk grain storage facilities, SA Part I4.","st":"SA","base":"E4D1","g":"/ncc/sa-e4d1"},{"c":"SA F1P2","t":"Rising damp","p":"SA Part F1 Water management","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-f1-water-management#_bce3f019-7b93-479e-b98d-e38ea50e887e","x":"Insert SA clause F1P2 in clause F1P2 as follows:\n(1) Moisture from the ground must be prevented from causing—\nundue dampness or deterioration of building elements; and\nunhealthy or dangerous conditions, or loss of amenity for occupants.\n(2) Barriers installed to prevent transfer of moisture from the ground must have—\nhigh resistance to moisture penetration; and\nhigh resistance to damage during construction; and\nhigh resistance to degradation by dissolved salts.","st":"SA","base":"F1P2","g":"/ncc/sa-f1p2"},{"c":"SA F1D1","t":"Deemed-to-Satisfy Provisions","p":"SA Part F1 Water management","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-f1-water-management#_fba811c6-4f7d-4be5-b5cd-b582a3ad1952","x":"Delete subclause F1D1(1) and insert SA F1D1(1) as follows:\n(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements F1P1 and SA F1P2 are satisfied by complying with F1D2 to F1D8, SA F1D9 and F1D10 to F1D15.","st":"SA","base":"F1D1","g":"/ncc/sa-f1d1"},{"c":"SA F1D2","t":"Application of Part","p":"SA Part F1 Water management","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-f1-water-management#_984d09ab-c1f8-4d7a-b426-47e80780a286","x":"Delete subclause F1D2(3) and insert SA F1D2(3) as follows:\n(3) F1D3 to F1D8, SA F1D9 and F1D10 to F1D15 do not apply to horizontal or near horizontal surfaces created by window hoods, spandrels, tops of parapets and other features.","st":"SA","base":"F1D2","g":"/ncc/sa-f1d2"},{"c":"SA F1D8","t":"Damp-proofing","p":"SA Part F1 Water management","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-f1-water-management#_c4b6da7c-9de7-451d-b5fa-dc3cf4a6ef85","x":"Delete subclause F1D8(2) and insert SA F1D8(2) as follows:\n(2) Damp-proof coursesmust exhibit long term resistance to degradation by dissolved salts in groundwater and consist of—\nembossed black polyethylene film meeting the requirements of clause 7.6 of AS/NZS 2904; or\npolyethylene coated aluminium meeting the requirements of clause 7.4 of AS/NZS 2904; or\nbitumen impregnated materials of not less than 2.5 mm thickness, meeting the requirements of clause 7.5 of AS/NZS 2904, when used in walls not higher than 7.8 m above the level of thedamp-proof course.","st":"SA","base":"F1D8","g":"/ncc/sa-f1d8"},{"c":"SA F1D9","t":"Damp-proofing of floors on the ground","p":"SA Part F1 Water management","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-f1-water-management#_231e4e27-5cf9-4d17-bf57-3466645b2eec","x":"Delete clause F1D9 and insert SA F1D9 as follows:\n(1) If a floor of a room is laid on the ground or on fill, a damp-proofing membrane complying with Section 5.3.3 of AS 2870 must be installed.\n(2) A damp-proofing membrane need not be provided if—\nweatherproofing is not required; or\nthe floor is the base of a stair, lift or similar shaft which is adequately drained by gravitation or mechanical means.","st":"SA","base":"F1D9","g":"/ncc/sa-f1d9"},{"c":"SA F2P1","t":"Wet area overflows","p":"SA Part F2 Wet areas and overflow protection","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-f2-wet-areas-and-overflow-protection#_c9f42ec5-ca41-4310-895b-234603e4811a","x":"Delete clause F2P1 and insert SA F2P1 as follows:\nOverflow from a bathroom, laundry facility or the like must be prevented from penetrating to adjoining rooms or spaces.","st":"SA","base":"F2P1","g":"/ncc/sa-f2p1"},{"c":"SA F2P3","t":"Prevention of surface water accumulation","p":"SA Part F2 Wet areas and overflow protection","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-f2-wet-areas-and-overflow-protection#_12b722ba-4631-4f0a-937d-1ef1b5acc8db","x":"Insert SA clause F2P3 in clause F2P3 as follows:\nIn laundries, bathrooms or rooms containing shower facilities the floors must be installed in a manner that will prevent accumulation of surface water which could create unhealthy or hazardous conditions.","st":"SA","base":"F2P3","g":"/ncc/sa-f2p3"},{"c":"SA F2D1","t":"Deemed-to-Satisfy Provisions","p":"SA Part F2 Wet areas and overflow protection","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-f2-wet-areas-and-overflow-protection#_6973617c-6c91-4baf-b01c-9462de03e9a4","x":"Delete subclause F2D1(1) and insert SA F2D1(1) as follows:\n(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements F2P1, F2P2 and SA F2P3 are satisfied by complying with F2D2 to F2D3 and SA F2D4.","st":"SA","base":"F2D1","g":"/ncc/sa-f2d1"},{"c":"SA F2D2","t":"Wet area construction","p":"SA Part F2 Wet areas and overflow protection","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-f2-wet-areas-and-overflow-protection#_1fa10c20-5d37-4bcb-bb82-95dec7704af3","x":"Delete subclause F2D2(1) and insert SA F2D2(1) as follows:\n(1) In a Class 2 and 3 building and a Class 4 part of a building, building elements in wet areas must—\nbe water resistant or waterproof in accordance with Specification 26, except that—\nin any room containing a washing machine, the wall area from finished floor to a minimum of 75 mm above and 75 mm each side of the washing machine tap outlets must be water resistant; and\nwhere a vessel is inset into a bench top in a kitchen, bar area, kitchenette or domestic food and beverage preparation area, the perimeter edges of the vessel must be water resistant for the extent of the vessel; and\npenetrations in horizontal surfaces for tap and spout outlets in kitchens, bar areas, kitchenettes or domestic food and beverage preparation areas must be waterproof; and\ncomply with AS 3740.","st":"SA","base":"F2D2","g":"/ncc/sa-f2d2"},{"c":"SA F2D4","t":"Provision of floor wastes","p":"SA Part F2 Wet areas and overflow protection","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-f2-wet-areas-and-overflow-protection#_3a4d4a6b-85d8-421d-a50a-313e3bb66d05","x":"Delete clause F2D4 and insert SA F2D4 as follows:\n(1) A wet area provided with a vessel in accordance with F4D2, F4D4 and F4D5 must have the floor graded to a floor waste to permit drainage of water.\n(2) With the exception of a bathroom or laundry located at any level above a sole-occupancy unit or public space in a Class 2 or 3 building or Class 4 part of a building, a floor need not be graded to a floor waste in accordance with (1) if—\nall vessels in the wet area are provided with in-built overflow protection or have permanent open trapped connection to the plumbing and drainage system (such as a WC pan); or\nthe vessel is a clinical hand washing basin in a Class 9c building; or\nthe floor waste is provided solely for the connection of plumbing fixtures and all vessel in the wet area are provided with in-built overflow protection or have permanent open trapped connection to the plumbing and drainage system (such as a WC pan).\n(3) The fall of the floor surface to a floor waste required by (1) or (2) must be in accordance with F2D4(2).","st":"SA","base":"F2D4","g":"/ncc/sa-f2d4"},{"c":"SA F4D1","t":"Deemed-to-Satisfy Provisions","p":"SA Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-f4-sanitary-and-other-facilities#_dbaa0e14-1b79-470e-b941-e72235978570","x":"Delete subclause F4D1(1) and insert SA F4D1(1) as follows:\n(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements F4P1 to F4P6 are satisfied by complying with—\nF4D2 to F4D12; and\nfor public transport buildings, Part I2.","st":"SA","base":"F4D1","g":"/ncc/sa-f4d1"},{"c":"SA F4D6","t":"Accessible unisex sanitary compartments","p":"SA Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-f4-sanitary-and-other-facilities#_5a1e2220-529a-4a38-b286-2aefd6d49b63","x":"Delete subclause F4D6(1) and insert SA F4D6(1) as follows:\n(1) Where required by F4D5(a), the minimum number of accessible unisex sanitary compartments for each Class of building is as follows:\nFor a Class 1b building—\nnot less than 1; and\nwhere private accessible unisex sanitary compartments are provided for every accessible bedroom, common accessible unisex sanitary compartments need not be provided.\nFor a Class 2 building—\nwhere sanitary compartments are provided in common areas, not less than 1; and\nin every sole-occupancy unit required by SA D4D2(4) to be accessible, not less than 1.\nFor Class 3 and Class 9c buildings—\nin every accessible sole-occupancy unit provided with sanitary compartments within the accessible sole-occupancy unit, not less than 1; and\nat each bank of sanitary compartments containing male and female sanitary compartments provided in common areas, not less than 1.\nFor Class 5, 6, 7, 8 or 9 buildings except for within a ward area of a Class 9a health-care building, where F4D4 requires closet pans—\n1 on every storey containing sanitary compartments; and\nwhere a storey has more than 1 bank of sanitary compartments containing male and female sanitary compartments, at not less than 50% of those banks.\nFor a Class 10a building appurtenant to another Class of building, at each bank of sanitary compartments containing male and female sanitary compartments, not less than 1.","st":"SA","base":"F4D6","g":"/ncc/sa-f4d6"},{"c":"SA F4D7","t":"Accessible unisex showers","p":"SA Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-f4-sanitary-and-other-facilities#_3d0b0c37-efd6-4d9e-8950-c461278dbfeb","x":"Delete subclause F4D7(1) and insert SA F4D7(1) as follows:\n(1) Where required by F4D5(b), the minimum number of accessible unisex showers for each Class of building is as follows:\nFor a Class 1b building—\nnot less than 1; and\nwhere private accessible unisex showers are provided for every accessible bedroom, common accessible unisex showers need not be provided.\nFor a Class 2 building—\nwhere showers are provided in common areas, not less than 1; and\nin every sole-occupancy unit required by SA D4D2(4) to be accessible, not less than 1.\nFor Class 3 and 9c buildings—\nin every accessible sole-occupancy unit provided with showers within the accessible sole-occupancy unit, not less than 1; and\n1 for every 10 showers or part thereof provided in common areas.\nFor Class 5, 6, 7, 8 or 9 buildings, where F4D4 requires 1 or more showers, not less than 1 for every 10 showers or part thereof.\nFor a Class 10a building, where showers are provided, 1 for every 10 showers or part thereof.","st":"SA","base":"F4D7","g":"/ncc/sa-f4d7"},{"c":"SA F5D1","t":"Deemed-to-Satisfy Provisions","p":"SA Part F5 Room heights","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-f5-room-heights#_85ee69f1-10a5-4221-9faf-877e0f0c7113","x":"Delete subclause F5D1(1) and insert SA F5D1(1) as follows:\n(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirement F5P1 is satisfied by complying with F5D2.","st":"SA","base":"F5D1","g":"/ncc/sa-f5d1"},{"c":"SA F6D1","t":"Deemed-to-Satisfy Provisions","p":"SA Part F6 Light and ventilation","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-f6-light-and-ventilation#_49ac1895-8fc4-4047-9d43-42988f04add3","x":"Delete subclause F6D1(1) and insert SA F6D1(1) as follows:\n(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements F6P1 to F6P5 are satisfied by complying with—\nF6D2 to F6D12; and\nfor a building containing an occupiable outdoor area, Part G6; and\nfor farm buildings, Part I3; and\nfor bulk grain storage facilities, SA Part I4.","st":"SA","base":"F6D1","g":"/ncc/sa-f6d1"},{"c":"SA G1P2","t":"Swimming pool access and water recirculation systems","p":"SA Part G1 Minor structures and components","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-g1-minor-structures-and-components#_4663b83b-6ced-429e-9d8f-7fb9a102dc20","x":"Delete clause G1P2 and insert SA G1P2 as follows:\n(1) A barrier must be provided to a swimming pool and must—\nbe continuous for the full extent of the hazard; and\nbe of a strength and rigidity to withstand the foreseeable impact of people; and\nrestrict the access of young children to the pool and the immediate pool surrounds; and\nhave any gates and doors fitted with latching devices not readily operated by young children, and constructed to automatically close and latch.\n(2) A swimming pool water recirculation system must incorporate safety measures to avoid entrapment of, or injury to, a person.\n(3) A swimming pool must have prominent and visible signage that assists persons to provide first aid and to perform cardiopulmonary resuscitation on young children.\nApplications\nSA G1P2 only applies to a swimming pool associated with a Class 2 or 3 building or Class 4 part of a building, with a depth of water more than 300 mm.","st":"SA","base":"G1P2","g":"/ncc/sa-g1p2"},{"c":"SA G1D1","t":"Deemed-to-Satisfy Provisions","p":"SA Part G1 Minor structures and components","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-g1-minor-structures-and-components#_b92512c9-09f6-4442-9e40-c62ceeb55478","x":"Delete subclause G1D1(1) and insert SA G1D1(1) as follows:\n(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements G1P1, SA G1P2, G1P3 to G1P5 are satisfied by complying with G1D2 to G1D5.","st":"SA","base":"G1D1","g":"/ncc/sa-g1d1"},{"c":"SA G1D2","t":"Swimming pools","p":"SA Part G1 Minor structures and components","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-g1-minor-structures-and-components#_e6526cf6-b0b2-4aaf-b143-b42daf463ad6","x":"Insert SA subclause G1D2(3) in clause G1D2 as follows:\n(3) For the purposes of clause 6.1.1 of AS 1926.3, a skimmer box is an outlet, and must have a means of releasing the vacuum pressure should the suction become blocked.\nInsert SA subclause G1D2(4) in clause G1D2 as follows:\n(4) A first aid and cardiopulmonary resuscitation sign must—\nbe attached to the safety barrier of the swimming pool, or displayed near the swimming pool; and\nbe at least 300 mm by 300 mm in size; and\nbe made of durable and weatherproof material; and\nshow information about the procedures for providing first aid, including performing cardiopulmonary resuscitation.","st":"SA","base":"G1D2","g":"/ncc/sa-g1d2"},{"c":"SA G5D1","t":"Deemed-to-Satisfy Provisions","p":"SA Part G5 Construction in bushfire prone areas","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-g5-construction-bushfire-prone-areas#_9d0fe6dd-3df5-4a13-85c4-fd5268a6c3e5","x":"Delete subclause G5D1(1) and insert SA G5D1(1) as follows:\n(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements G5P1 and subject to G5D2, G5P2, are satisfied by complying with G5D3 to SA G5D5.","st":"SA","base":"G5D1","g":"/ncc/sa-g5d1"},{"c":"SA G5D5","t":"Bushfire attack levels","p":"SA Part G5 Construction in bushfire prone areas","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-g5-construction-bushfire-prone-areas#_bac23c52-c978-4143-a93b-902c30e5b98e","x":"Insert SA clause G5D5 in clause G5D5 as follows:\nWhere a site is located in a designated bushfire prone area, the bushfire attack level that applies to the site is—\nfor areas identified as general bushfire risk areas in the Planning and Design Code, the BAL-Low bushfire attack level; and\nfor areas identified as medium bushfire risk areas in the Planning and Design Code, the BAL-12.5 bushfire attack level; and\nfor areas identified as high bushfire risk areas in the Planning and Design Code, the bushfire attack level assessed for the site in accordance with the requirements of AS 3959; and\nfor areas identified as urban interface in the Planning and Design Code that are within 500 m of a high bushfire risk area, the BAL-Low bushfire attack level; and\nfor areas identified as urban interface in the Planning and Design Code that are within 100 m of a high bushfire risk area, the bushfire attack level assessed for the site in accordance with AS 3959.","st":"SA","base":"G5D5","g":"/ncc/sa-g5d5"},{"c":"SA G7D2","t":"Livable housing design","p":"SA Part G7 Livable housing design","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-g7-livable-housing-design#_78af8a14-05bf-40b2-a42c-197be6dc47eb","x":"Delete clause G7D2 and insert SA G7D2 as follows:\n(1) Each sole-occupancy unit in a Class 2 building must comply with the ABCB Standard for Livable Housing Design, except for Part 1.\n(2) The sanitary compartment that is subject to Clause 4.1 of the ABCB Standard for Livable Housing Design may be located on either:\nthe ground or entry level; or\nthe lowest level containing a habitable room within the sole-occupancy unit of a Class 2 building.","st":"SA","base":"G7D2","g":"/ncc/sa-g7d2"},{"c":"SA G8O1","t":"Objective","p":"SA Part G8 Access for maintenance","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-g8-access-maintenance#_44ae00a6-a07a-47fd-b835-5010995ba27e","x":"Delete clause G8O1 and insert SA G8O1 as follows:\nThe Objectives of this Part are—\nto safeguard people from injury while cleaning windows; and\nto safeguard people from injury or illness resulting from the creation of hazardous spaces between buildings.","st":"SA","base":"G8O1","g":"/ncc/sa-g8o1"},{"c":"SA G8F1","t":"Window cleaning","p":"SA Part G8 Access for maintenance","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-g8-access-maintenance#_ef8fa1ed-66c5-48cb-9f5c-097e9e9003e6","x":"Delete clause G8F1 and insert SA G8F1 as follows:\nA building is to provide people with safe conditions for carrying out window cleaning operations.","st":"SA","base":"G8F1","g":"/ncc/sa-g8f1"},{"c":"SA G8F2","t":"Hazardous conditions","p":"SA Part G8 Access for maintenance","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-g8-access-maintenance#_c03c26b9-78ea-444b-b8b7-f924c23c0d4e","x":"Delete clause G8F2 and insert SA G8F2 as follows:\nThe space between buildings must not allow hazardous conditions to arise due to accumulation of rubbish that cannot readily be removed.","st":"SA","base":"G8F2","g":"/ncc/sa-g8f2"},{"c":"SA G8P1","t":"Window cleaning","p":"SA Part G8 Access for maintenance","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-g8-access-maintenance#_57753e6b-bbba-4180-a0ae-e7d2c732b61e","x":"Delete clause G8P1 and insert SA G8P1 as follows:\nWhere any part of a window in a building is more than 5.5 m above ground level, provision must be made for safe access to the external surface of the window for minor maintenance and cleaning.","st":"SA","base":"G8P1","g":"/ncc/sa-g8p1"},{"c":"SA G8P2","t":"Hazardous conditions","p":"SA Part G8 Access for maintenance","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-g8-access-maintenance#_5a8e098d-47d3-44fb-8dd0-8f3f47b987c8","x":"Delete clause G8P2 and insert SA G8P2 as follows:\nThe space between buildings must be sufficient to allow access for inspection and maintenance, to avoid hazardous conditions arising due to accumulation of rubbish that could—\nbridge termite barriers; or\nharbour vermin; or\ncreate a fire hazard.","st":"SA","base":"G8P2","g":"/ncc/sa-g8p2"},{"c":"SA G8D1","t":"Deemed-to-Satisfy Provisions","p":"SA Part G8 Access for maintenance","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-g8-access-maintenance#_36707c3a-a9e7-4686-be95-f8fe0fb3ada4","x":"Delete clause G8D1 and insert SA G8D1 as follows:\nPerformance Requirements SA G8P1 and SA G8P2 are satisfied by complying with SA G8D2 to SA G8D4.","st":"SA","base":"G8D1","g":"/ncc/sa-g8d1"},{"c":"SA G8D2","t":"Application of Part","p":"SA Part G8 Access for maintenance","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-g8-access-maintenance#_b219f268-5087-4568-9f17-0c6a4c50da92","x":"Delete clause G8D2 and insert SA G8D2 as follows:\nSA G8D3 and SA G8D4 apply to Class 2 to 9 buildings.","st":"SA","base":"G8D2","g":"/ncc/sa-g8d2"},{"c":"SA G8D3","t":"Access for window cleaning","p":"SA Part G8 Access for maintenance","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-g8-access-maintenance#_8d8aac3b-1628-4b1d-938f-632439961ecb","x":"Delete clause G8D3 and insert SA G8D3 as follows:\n(1) Where any part of a window in a building is more than 5.5 m above ground level, access to the external surface of the window for minor maintenance and cleaning must be provided.\n(2) Any of the following methods are acceptable—\nby means of a movable gantry; or\nby means of reversible pivoting sashes, each of which has catches that secure the mesh in either the normal or reversed position and give visual indication that the window is secure, provided that where a window sill is less than 900 mm above floor level, safety anchorages are provided; or\nby means of safety harness, having all anchorages—\ndesigned and installed in accordance with AS/NZS 1891.4; and\nconstructed of approved corrosion resistant material; or\nby means of opening sashes, in which the maximum reach to the farthest part of the window must not exceed 500 mm upwards or 1 m sideways or downwards and provided that where the window sill is less than 900 mm above floor level, safety anchorages are provided.","st":"SA","base":"G8D3","g":"/ncc/sa-g8d3"},{"c":"SA G8D4","t":"Access for inspection and maintenance between buildings","p":"SA Part G8 Access for maintenance","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-g8-access-maintenance#_fb030a71-d407-4c31-9de3-fb0bed7027d6","x":"Delete clause G8D4 and insert SA G8D4 as follows:\nEvery part of an external wall of a building must be not less than 600 mm from—\nthe external wall of any other building on the same allotment, unless the two buildings are abutting; or\nany boundary of the allotment, unless that wall is on or abutting the boundary,\nunless the space between external columns is not infilled.","st":"SA","base":"G8D4","g":"/ncc/sa-g8d4"},{"c":"SA G9P1","t":"Attachments to buildings","p":"SA Part G9 Miscellaneous provisions","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-g9-miscellaneous-provisions#_4707fd7a-5e63-434f-81ac-32e033fb411c","x":"Delete clause G9P1 and insert SA G9P1 as follows:\nAn attachment to a building must incorporate features that will—\nprotect it against corrosion; and\ncollect and discharge water run-off safely; and\nprevent its projection affecting adjacent road safety conditions or pedestrian traffic; and\nprovide resistance to the spread of fire if it overhangs a street boundary,\nto the degree necessary to avoid creating hazardous conditions that may cause injury to people passing below or driving past.","st":"SA","base":"G9P1","g":"/ncc/sa-g9p1"},{"c":"SA G9D1","t":"Deemed-to-Satisfy Provisions","p":"SA Part G9 Miscellaneous provisions","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-g9-miscellaneous-provisions#_f28811a4-9ec6-4844-a371-ea5d0210a2d9","x":"Delete clause G9D1 and insert SA G9D1 as follows:\nPerformance Requirement SA G9P1 is satisfied by complying with SA G9D2 and SA G9D3.","st":"SA","base":"G9D1","g":"/ncc/sa-g9d1"},{"c":"SA G9D2","t":"Application of Part","p":"SA Part G9 Miscellaneous provisions","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-g9-miscellaneous-provisions#_da110e5d-ed91-4461-8a0b-ba1ed3b9913d","x":"Delete clause G9D2 and insert SA G9D2 as follows:\nSA G9D3 applies to Class 2 to 9 buildings.","st":"SA","base":"G9D2","g":"/ncc/sa-g9d2"},{"c":"SA G9D3","t":"Attachments to buildings","p":"SA Part G9 Miscellaneous provisions","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-g9-miscellaneous-provisions#_414cb764-adb3-47fe-aab1-7221f5072aee","x":"Delete clause G9D3 and insert SA G9D3 as follows:\n(1) An attachment to a building that is in the nature of a balcony or awning, bridge, gangway, hoarding or trade sign, sky sign, mast, flagpole, tower, aerial or antenna, lantern, cathead, crane, chimney, flue or duct, or an installation for cleaning and maintenance must—\nhave all metal parts of corrosion resistant metal, or other metal suitably protected; and\nnot overhang any street boundary at a height less than 2.5 m above the footpath, or 4 m above the roadway; and\nbe provided with drainage to prevent rainwater or condensate falling onto or running across the footpath, unless either it is a retractable awning in the nature of a sun blind, or unless the total catchment area for run-off is less than 1.5 m2.\n(2) A balcony or awning that overhangs a street boundary—\nmust not extend closer than 450 mm to the kerb of the roadway; and\nmust be constructed of non-combustible or fire-retardant materials throughout, except that timber battens may be used to support the soffit lining.","st":"SA","base":"G9D3","g":"/ncc/sa-g9d3"},{"c":"SA I3D1","t":"Application of Part","p":"SA Part I3 Farm buildings and farm sheds","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-i3-farm-buildings-and-farm-sheds#_8667a205-5e85-472b-81a9-c5ff81c763c2","x":"Delete clause I3D1 and insert SA I3D1 as follows:\n(1) The Deemed-to-Satisfy Provisions of this Part apply to farm buildings in South Australia.\n(2) The Deemed-to-Satisfy Provisions of this Part take precedence where there is a difference to the Deemed-to-Satisfy Provisions of Sections C, D, E and F.","st":"SA","base":"I3D1","g":"/ncc/sa-i3d1"},{"c":"SA I3D2","t":"Fire resistance and separation","p":"SA Part I3 Farm buildings and farm sheds","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-i3-farm-buildings-and-farm-sheds#_id16812","x":"This clause has deliberately been left blank.","st":"SA","base":"I3D2","g":"/ncc/sa-i3d2"},{"c":"SA I3D3","t":"Provision for escape","p":"SA Part I3 Farm buildings and farm sheds","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-i3-farm-buildings-and-farm-sheds#_bdd70c0f-aa1c-475b-94e9-d222cc77117c","x":"Delete clause I3D3 and insert SA I3D3 as follows:\n(1) Exit travel distances in a farm building must comply with D2D5 except—\nno point on the floor must be more than 20 m from an exit, or a point from which travel in different directions to 2 exits is available, in which case the maximum distance to one of those exits must not exceed 60 m; and\nin a machinery room, plant room or the like, the distance to a single exit serving a storey at the level of access to a road or open space may be increased to 30 m.\n(2) Exits that are required as alternative means of egress in a farm building must be in accordance with D2D6 except they must not be more than 80 m apart.","st":"SA","base":"I3D3","g":"/ncc/sa-i3d3"},{"c":"SA I3D4","t":"Construction of exits","p":"SA Part I3 Farm buildings and farm sheds","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-i3-farm-buildings-and-farm-sheds#_id16838","x":"This clause has deliberately been left blank.","st":"SA","base":"I3D4","g":"/ncc/sa-i3d4"},{"c":"SA I3D5","t":"Fixed platforms, walkways, stairways and ladders","p":"SA Part I3 Farm buildings and farm sheds","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-i3-farm-buildings-and-farm-sheds#_6faf6b20-89f6-4b00-93ce-2b0c05e76637","x":"Delete clause I3D5 and insert SA I3D5 as follows:\nA fixed platform, stairway, ladder and any going and riser, landing, handrail or barrier may comply with AS 1657 in lieu of D3D14, D3D15, D3D17 to D3D21 and D3D22 where it serves a farm building.","st":"SA","base":"I3D5","g":"/ncc/sa-i3d5"},{"c":"SA I3D8","t":"Fire fighting equipment","p":"SA Part I3 Farm buildings and farm sheds","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-i3-farm-buildings-and-farm-sheds#_id16856","x":"This clause has deliberately been left blank.","st":"SA","base":"I3D8","g":"/ncc/sa-i3d8"},{"c":"SA I3D9","t":"Fire hydrants and water supplies","p":"SA Part I3 Farm buildings and farm sheds","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-i3-farm-buildings-and-farm-sheds#_d88b0e13-cc20-4b3f-a8e0-10e43256a207","x":"Delete clause I3D9 and insert SA I3D9 as follows:\n(1) A farm building need not be provided with a fire hydrant system in accordance with E1D2, if it has—\na fire hydrant system installed in accordance with AS 2419.1 except—\nin lieu of 4 hour water supply the minimum on-site water supply quantity must be as set out in Table SA I3D9 for the particular building group; and\nfor Group A and B buildings over 1000 m2 in floor area each tank used must have a capacity of not less than 72,000 litres; and\nfor single tank systems compliance with clause 4.3.3 is not required; and\ncompliance with clause 4.3.1 of AS 2419.1 is not required; and\nfor buildings incorporating non-fire resistant polystyrene sandwich panel construction, the minimum water supply quantities in Table SA I3D9 must be increased by 50%; and\nan on-site pumpset is not required if the design performance of section 2.3 of AS 2419.1 is achieved based on use of a fire truck pump with a capacity of 1,900 litres per minute at 1,000 kPa; and\nin lieu of the coverage specified in AS 2419.1, external fire hydrants are located so that every part of the perimeter of a building is within 100 m from a hydrant outlet measured along the shortest distance of travel between or around buildings; or\na water supply system comprising single or multiple on-site water storage tanks with connections for use by the fire brigade and complying with the requirements of AS 2419.1 for water supplies and water storage, except—\nin lieu of 4 hour water supply the minimum on-site water supply quantity must be as set out in Table SA I3D9 for the particular building group; and\nfor Group A and B buildings over 1000 m2 in floor area each tank used must have a capacity of not less than 72,000 litres; and\nfor single tank systems compliance with clause 4.3.3 of AS 2419.1 is not required; and\nfor buildings incorporating non-fire-resistant polystyrene sandwich panel construction, the minimum water supply quantities in Table SA I3D9 must be increased by 50%; and\nan on-site pumpset need not be provided; and\nGroup A or B buildings water storage tanks must be distributed so every part of the perimeter of a building is not more than 100 m from a tank suction point, measured along the shortest distance of travel between or around buildings; and\nfor Group C buildings water storage tanks must be distributed so that every part of the perimeter of a building is within a 200 m radius of a tank suction point; and\nall pipes, valves and fittings for water storage tanks and connections must comply with section 5 and sections 8.2, 8.3, 8.6 and 8.7 of AS 2419.1 as relevant.\n(2) A dam may be regarded as a water storage tank if it complies with the requirements of section 5 of AS 2419.1 and the water level is maintained above the top of the highest fire brigade suction point at all times.\n(3) A hardstand area and vehicular approach from the site entrance, suitable for use by the fire brigade must be provided adjacent to each water storage tank provided under (1)(b).\nInsert SA table (I3D9) I3D9 as follows:\nSA Table I3D9: Minimum quantities for on site water supplies for farm buildings\nBuilding Group\nFloor area (m2)\nMinimum water supply quantity (L)\nGroup A\n500 to 1,000\n36,000\n1,001 to 2,000\n72,000\n2,001 to 5,000\n144,000\nGroup B\n500 to 1,000\n72,000\n1,001 to 2,000\n144,000\nGroup C\n5 L/m2 or 36,000 L at each location, whichever is greater.\nTable Notes\nA single water supply with the minimum water quantity outlined in Table SA I3D9 can serve more than one building.","st":"SA","base":"I3D9","g":"/ncc/sa-i3d9"},{"c":"SA I3D10","t":"Fire hose reels","p":"SA Part I3 Farm buildings and farm sheds","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-i3-farm-buildings-and-farm-sheds#_694a0f37-4e2d-4970-acde-8bb51f3d0d97","x":"Delete clause I3D10 and insert SA I3D10 as follows:\nE1D3 does not apply to a farm building except when it is used for hay storage exceeding 500 m2 or 1,000 m3.","st":"SA","base":"I3D10","g":"/ncc/sa-i3d10"},{"c":"SA I3D11","t":"Portable fire extinguishers","p":"SA Part I3 Farm buildings and farm sheds","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-i3-farm-buildings-and-farm-sheds#_a2284d76-7a54-436e-8084-68b9691a550f","x":"Delete clause I3D11 and insert SA I3D11 as follows:\n(1) For Class A fire risks in a farm building the requirements of E1D14 need not be provided if—\nportable fire extinguishers for Class A fire risks are provided in accordance with SA I3D11(2); or\nnotwithstanding the exemption provided by SA I3D10, a fire hose reel system is provided in accordance with E1D3, or wash-down hoses or similar hoses that are—\nnot more than 36 m long; and\nequipped with a spray nozzle suitable for fighting a fire at the incipient stage; and\npermanently connected to a water supply which is sufficient to supply two hoses discharging at the rate of 20 litres per minute for 60 minutes; and\narranged to provide coverage to all points on the floor within.\n(2) Portable fire extinguishers provided to comply with SA I3D11(1)(a) must be—\nlocated at or adjacent to every required exit; or\nin open walled farm buildings, one extinguisher is provided for every 500 m2 of floor area, or part thereof.","st":"SA","base":"I3D11","g":"/ncc/sa-i3d11"},{"c":"SA I3D12","t":"Emergency lighting requirements","p":"SA Part I3 Farm buildings and farm sheds","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-i3-farm-buildings-and-farm-sheds#_371504f1-55b4-4424-a32f-675336e77546","x":"Delete clause I3D12 and insert SA I3D12 as follows:\nAn emergency lighting system complying with E4D2 must be installed in a farm building except that—\nany area primarily used for the storage of hay can be excluded when calculating the floor area of the storey or room of the building for the purpose of determining emergency lighting requirements; and\nemergency lighting is not required where automatic back-up power is provided by a fuel driven back up generator or where no artificial lighting is provided in the building; and\nan emergency lighting system is not required in a Group C farm building.","st":"SA","base":"I3D12","g":"/ncc/sa-i3d12"},{"c":"SA I3D13","t":"Exit signs","p":"SA Part I3 Farm buildings and farm sheds","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-i3-farm-buildings-and-farm-sheds#_e7f4c59d-fe9b-43a9-b1cd-3982e9e2d929","x":"Delete clause I3D13 and insert SA I3D13 as follows:\nAn exit sign must be clearly visible to persons approaching the exit, and must be installed on, above or adjacent to each required exit in a farm building.","st":"SA","base":"I3D13","g":"/ncc/sa-i3d13"},{"c":"SA I3D14","t":"Direction signs","p":"SA Part I3 Farm buildings and farm sheds","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-i3-farm-buildings-and-farm-sheds#_855368f2-92db-4fd0-85c3-1223d7324d4f","x":"Delete clause I3D14 and insert SA I3D14 as follows:\nIn a farm building, if an exit is not readily apparent to persons occupying or visiting the building, exit signs complying with SA I3D15 must installed in appropriate positions in corridors, hallways, lobbies and the like, indicating the direction to a required exit.","st":"SA","base":"I3D14","g":"/ncc/sa-i3d14"},{"c":"SA I3D15","t":"Design and operation of exit signs","p":"SA Part I3 Farm buildings and farm sheds","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-i3-farm-buildings-and-farm-sheds#_12a76732-402b-4334-ad74-f5339bf514ce","x":"Delete clause I3D15 and insert SA I3D15 as follows:\nIn a farm building, each required exit sign provided under E4D5, SA I3D13 and SA I3D14 need not comply with E4D8 if—\nthe use of illuminated exit signs may adversely impact the behaviour or welfare of animals being kept in the building; and\nnon-illuminated exit signs are installed in accordance with the requirements of Appendix D of AS/NZS 2293.1 as for an externally illuminated exit sign, and clauses 5.6 and 5.8 of AS/NZS 2293.1.","st":"SA","base":"I3D15","g":"/ncc/sa-i3d15"},{"c":"SA I3D16","t":"Sanitary facilities","p":"SA Part I3 Farm buildings and farm sheds","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-i3-farm-buildings-and-farm-sheds#_id17000","x":"This clause has deliberately been left blank.","st":"SA","base":"I3D16","g":"/ncc/sa-i3d16"},{"c":"SA I3D17","t":"Height of rooms and other spaces","p":"SA Part I3 Farm buildings and farm sheds","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-i3-farm-buildings-and-farm-sheds#_id17005","x":"This clause has deliberately been left blank.","st":"SA","base":"I3D17","g":"/ncc/sa-i3d17"},{"c":"SA I3D18","t":"Artificial lighting","p":"SA Part I3 Farm buildings and farm sheds","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-i3-farm-buildings-and-farm-sheds#_5b5d77b8-abce-417b-895e-29132239d7eb","x":"Delete clause I3D18 and insert SA I3D18 as follows:\nAn artificial lighting system need not be provided in a farm building where—\noccupants are provided with visibility sufficient for safe movement through suitable alternative means; and\nthe use of artificial lighting could adversely affect the function of the building including, but not limited to—\nthe behaviour or welfare of animals being kept in the building; or\nthe cultivating or propagating of plants or fungi.","st":"SA","base":"I3D18","g":"/ncc/sa-i3d18"},{"c":"SA I4D1","t":"Application of Part","p":"SA Part I4 Bulk grain storage facilities","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-i4-bulk-grain-storage-facilities#_7dfe48b1-206d-4f0a-a602-a743be51a3d5","x":"Delete clause I4D1 and insert SA I4D1 as follows:\n(1) The Deemed-to-Satisfy Provisions of this Part apply to bulk grain storage facilities in South Australia.\n(2) The Deemed-to-Satisfy Provisions of this Part take precedence where there is a difference to the Deemed-to-Satisfy Provisions of Sections C, D, E and F.","st":"SA","base":"I4D1","g":"/ncc/sa-i4d1"},{"c":"SA I4D2","t":"Type of construction required","p":"SA Part I4 Bulk grain storage facilities","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-i4-bulk-grain-storage-facilities#_d0b6cb8e-1dac-43e3-9cac-9a6bac0c65a4","x":"Delete clause I4D2 and insert SA I4D2 as follows:\nThe external walls of a bulk grain storage facility need not be of fire-resisting construction in accordance with Table C2D2 if—\nthe external walls are 3 m or more from an allotment boundary and more than 6 m from any other building on the same allotment, other than a Class 10 building; and\na fire separation space of not less than 2 m is provided between cell type silos; and\nthe external walls are of—\nnon-combustible construction; or\nType C construction.","st":"SA","base":"I4D2","g":"/ncc/sa-i4d2"},{"c":"SA I4D3","t":"Compartmentation","p":"SA Part I4 Bulk grain storage facilities","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-i4-bulk-grain-storage-facilities#_742f82df-71ea-4e8a-88ff-f190d8af539d","x":"Delete clause I4D3 and insert SA I4D3 as follows:\nUnderground passageways in a bulk grain storage facility must be separated from other parts of the building by smoke proof walls and smoke-proof doors complying with Specification 11.","st":"SA","base":"I4D3","g":"/ncc/sa-i4d3"},{"c":"SA I4D4","t":"Protection of openings","p":"SA Part I4 Bulk grain storage facilities","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-i4-bulk-grain-storage-facilities#_f36f5add-48f8-4447-a0b6-7fa2005ebcf4","x":"Delete clause I4D4 and insert SA I4D4 as follows:\nWhere external stairs, ramps or ladders are used as an exit in a bulk grain storage facility —\nany window or door opening within 6 m of the stairway or ladder must be protected in accordance with C4D5; or\nthe stairway, ramp or ladder must be enclosed for its full height above the lowest level of the window or door opening with non-combustible construction having an FRL of not less than 60/60/60.","st":"SA","base":"I4D4","g":"/ncc/sa-i4d4"},{"c":"SA I4D5","t":"Provision for escape","p":"SA Part I4 Bulk grain storage facilities","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-i4-bulk-grain-storage-facilities#_b2793ce3-60fd-4d5e-b4ab-8e1a63b7d42f","x":"Delete clause I4D5 and insert SA I4D5 as follows:\n(1) In addition to any horizontal exit, not less than 2 exits must be provided from—\na storage shed in a bulk grain storage facility if the distance of travel to an exit is more than 150 m; and\nthe gallery level in a cell type silo in a bulk grain storage facility.\n(2) A stairway or ramp serving as a required exit from a bulk grain storage facility is not required to be fire-isolated where there are no window or door openings within 3 m of the stairway, ramp or ladder.\n(3) Where required exits are spaced not more than 100 m apart in a bulk grain storage facility, the travel distance to an exit in a cell type silo or storage shed is not limited to D2D5(3).\n(4) In a bulk grain storage facility, the distance from any point on the floor to a point of egress to a road or open space by way of a non-fire-isolated stairway, non-fire-isolated ramp or ladder is not limited.\n(5) A stair or ladder complying with AS 1657 may be used in a bulk grain storage facility as an alternative means of egress from a cell type silo.","st":"SA","base":"I4D5","g":"/ncc/sa-i4d5"},{"c":"SA I4D6","t":"Fire hydrants and water supplies","p":"SA Part I4 Bulk grain storage facilities","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-i4-bulk-grain-storage-facilities#_3aa01c5c-9d8d-471e-a622-ddf60c54453c","x":"Delete clause I4D6 and insert SA I4D6 as follows:\n(1) A bulk grain storage facility need not provide an on-site fire hydrant system in accordance with E1D2, where—\nstreet hydrants are available adjacent to the site that can supply water at not less than 5 litres per second; or\na water supply system comprising single or multiple on-site water storage tanks with connections for use by the fire brigade and complying with the requirements of AS 2419.1 for water supplies and water storage is provided, except—\nin lieu of a 4 hour water supply, an on0site water storage tank containing not less than 25,000 litres is provided within 90 m of a dry booster connection Figure SA I4D6; and\none dry riser is provided for each cell type silo, located in the middle of the longest side of the bulk grain storage facility and within 4 m of a required exit; and\nall areas to be protected are within 60 m of a riser outlet, measured around obstacles; and\nmetal or high pressure plastic pipe can used for the dry riser; and\nall pipes, valves and fittings for water storage tanks and connections must comply with section 5 and sections 8.2, 8.3, 8.6 and 8.7 of AS 2419.1 as relevant.\n(2) A dam may be regarded as a water storage tank if it complies with the requirements of section 5 of AS 2419.1 and the water level is maintained above the top of the highest fire brigade suction point at all times.\n(3) A hardstand area and vehicular approach from the site entrance, suitable for use by the fire brigade, must be provided adjacent to each water storage tank provided under (1)(b).\nInsert SA figure (I4D6) I4D6 as follows:\nSA Figure I4D6: Location of hydrants, tanks, booster connections and dry risers","st":"SA","base":"I4D6","g":"/ncc/sa-i4d6"},{"c":"SA I4D7","t":"Fire hose reels","p":"SA Part I4 Bulk grain storage facilities","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-i4-bulk-grain-storage-facilities#_c65087c3-9b02-44ea-a95c-c388d9b5f6f5","x":"Delete clause I4D7 and insert SA I4D7 as follows:\nE1D3 does not apply to a bulk grain storage facility.","st":"SA","base":"I4D7","g":"/ncc/sa-i4d7"},{"c":"SA I4D8","t":"Smoke venting","p":"SA Part I4 Bulk grain storage facilities","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-i4-bulk-grain-storage-facilities#_bee11a2f-3c39-4bba-8495-74660b13a17a","x":"Delete clause I4D8 and insert SA I4D8 as follows:\n(1) In a bulk grain storage facility, suitable natural smoke venting by fixed vents must be provided at the top of elevator towers and overhead galleries in a cell type silo.\n(2) Smoke venting is not required in a storage shed of a bulk grain storage facility.","st":"SA","base":"I4D8","g":"/ncc/sa-i4d8"},{"c":"SA I4D9","t":"Emergency lighting requirements","p":"SA Part I4 Bulk grain storage facilities","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-i4-bulk-grain-storage-facilities#_01f90564-2135-48ba-b46d-81ea83e9d64b","x":"Delete clause I4D9 and insert SA I4D9 as follows:\n(1) An emergency lighting system complying with E4D2 must be installed in a bulk grain storage facility except that—\nemergency lighting is not required at ground floor level in cell type silos or storage sheds; and\nthe spacing of emergency lights can be increased to twice the distance required for Class 7 building.\n(2) An emergency lighting system complying with E4D2 must be installed in an underground passage in a bulk grain storage facility.","st":"SA","base":"I4D9","g":"/ncc/sa-i4d9"},{"c":"SA I4D10","t":"Ventilation","p":"SA Part I4 Bulk grain storage facilities","u":"/editions/ncc-2025/adopted/volume-one/8-south-australia/sa-i4-bulk-grain-storage-facilities#_a60e564b-f1c0-4b5a-9be5-d4182d19f26a","x":"Delete clause I4D10 and insert SA I4D10 as follows:\nIn a bulk grain storage facility, a habitable room, office, shop, factory, workroom, sanitary compartment, bathroom, shower room, laundry and any other room occupied by a person for any purpose must have a ventilation system that provides one air change every six hours using openings that have a total area of the lesser of—\n35 m2; or\none percent of the total floor area.","st":"SA","base":"I4D10","g":"/ncc/sa-i4d10"},{"c":"TAS A1G4","t":"Interpretation","p":"TAS Part A1 Interpreting the NCC","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-a1-interpreting-ncc#_df8e2b6b-e97a-4ac8-bd0b-37a4a3ab9efb","x":"Insert TAS subclause A1G4(7) in clause A1G4 as follows:\n(7) The Director of Building Control may issue written advice to deal with arising issues such as interpretation of codes, standards and regulations.","st":"TAS","base":"A1G4","g":"/ncc/tas-a1g4"},{"c":"TAS A5G4","t":"Evidence of suitability ─ Volume Three (PCA)","p":"TAS Part A5 Documentation of design and construction","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-a5-documentation-design-and-construction#_ad4e40c1-74c6-414d-a401-2a2ae1f0833e","x":"Insert TAS subclause A5G4(7) in clause A5G4 as follows:\n(7) A product used in roof plumbing, heating ventilation and air-conditioning or on-site liquid trade waste are deemed fit to be for their intended purpose if it has evidence of suitability in the form of—\nWaterMark Licence issued in accordance with the WaterMark Certification Scheme; or\na current certificate issued by a certification body stating that the properties and performance of a product meet the requirements of the NCC Volume Three; or\nauthorisation from the Director of Building Control.\nInsert TAS subclause A5G4(8) in clause A5G4 as follows:\n(8) A product used in On-site wastewater management systems are deemed to be fit for their intended purpose if it has evidence of suitability in the form of—\nan On-site wastewater management system used in a plumbing installation must be issued with a Certificate of Accreditation in accordance with the AS 1546 series of Standards; or\na current certificate issued by a JAS-ANZ accredited certification body stating that the properties and performance of a product meets the requirement of NCC Volume Three; and\naccreditation from the Director of Building Control.\nInsert TAS subclause A5G4(9) in clause A5G4 as follows:\n(9) A holding tank or collection well for use in a plumbing or drainage installation may be verified as meeting the Performance Requirements of the Director of Building Control if complies with AS/NZS 1546.1.\nInsert TAS subclause A5G4(10) in clause A5G4 as follows:\n(10) Under the Tasmanian Building Act, the Director of Building Control may accredit an On-site wastewater management system. On-site wastewater management systems larger than that covered by the Australian Standards AS/NZS 1546 Series are exempt from accreditation and a Performance Solution is required.\nProducts accredited by the Director of Building Control are published in a list available at www.cbos.tas.gov.au.","st":"TAS","base":"A5G4","g":"/ncc/tas-a5g4"},{"c":"TAS D1P10","t":"Standards made under the Disability Discrimination Act","p":"TAS Part D1 Access and egress","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-d1-access-and-egress#_96dcdb06-3963-4f2d-9b92-71d2e0711f22","x":"Insert TAS clause D1P10 in clause D1P10 as follows:\nA building or part of a building must be accessible in accordance with the requirements of a Standard made under the Disability Discrimination Act 1992 (Cth).","st":"TAS","base":"D1P10","g":"/ncc/tas-d1p10"},{"c":"TAS D4D1","t":"Deemed-to-Satisfy Provisions","p":"TAS Part D4 Access for people with a disability","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-d4-access-people-disability#_7a9879ea-6a1a-4927-953b-379204666cb4","x":"Delete subclause D4D1(1) and insert TAS D4D1(1) as follows:\n(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements D1P1 to D1P6, D1P8, D1P9 and TAS D1P10 are satisfied by complying with—\nD2D2 to D2D23, D3D2 to D3D30, D4D2 to D4D13 and TAS D4D14; and\nin a building containing an atrium, Part G3; and\nadditional requirements for Class 9b buildings, Part I1; and\nfor public transport buildings, Part I2.\nDelete subclause D4D1(3) and insert TAS D4D1(3) as follows:\n(3) This sub-clause has deliberately been left blank.","st":"TAS","base":"D4D1","g":"/ncc/tas-d4d1"},{"c":"TAS D4D5","t":"Exemptions","p":"TAS Part D4 Access for people with a disability","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-d4-access-people-disability#_edb19315-cff8-4df5-b98d-2ea4b63a1f04","x":"Delete clause D4D5 and insert TAS D4D5 as follows:\nThe following areas are not required to be accessible:\nAn area where access would be inappropriate because of the particular purpose for which the area is used.\nAn area that would pose a health or safety risk for people with a disability.\nAny path of travel providing access only to an area exempted by (a) or (b).\nThe Class 2 parts of a building where—\nthe building is an existing building with a rise in storeys of two; and\nthe storey at ground level is Class 5 or 6; and\nthe upper storeys is comprised of two or more Class 2 sole-occupancy units that are not made available for short-term rental.","st":"TAS","base":"D4D5","g":"/ncc/tas-d4d5"},{"c":"TAS D4D14","t":"Compliance with Premises Standards","p":"TAS Part D4 Access for people with a disability","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-d4-access-people-disability#_e156a31a-224c-4cfc-8b97-c39b319eb1d8","x":"Insert TAS clause D4D14 in clause D4D14 as follows:\n(1) A building solution must comply with the Disability (Access to Premises - Buildings) Standards 2010.\n(2) A building solution complies with TAS D4D1(1)(a) if it complies with the applications, exemptions and concessions in the Disability (Access to Premises - Buildings) Standards 2010.","st":"TAS","base":"D4D14","g":"/ncc/tas-d4d14"},{"c":"TAS E1P7","t":"Automatic fire detection system","p":"TAS Part E1 Fire fighting equipment","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-e1-fire-fighting-equipment#_85520e95-8b58-4eb1-97e8-3ad50fb9bd6a","x":"Insert TAS clause E1P7 in clause E1P7 as follows:\nAn automatic fire detection system must be installed to the degree necessary to alert the fire brigade of fire so that fire fighting operations may be undertaken at the earliest possible time to limit property and environmental damage appropriate to—\nthe building functions and use; and\nthe fire hazard; and\nthe height of the building; and\nthe building floor area.\nApplications\nTas E1P7 only applies to—\na Class 5 building or Class 6 building having an aggregate floor area of more than 1000 m2; and\na Class 7 building having a floor area of more than 1000 m2 in which furniture is stored; and\na Class 8 building which is a special fire hazard building and in which more than 25 persons are employed; and\na Class 9b building which is a school or early childhood centre or a creche which—\nis of more than 1 storey; or\nhas a storey with a floor area more than 500 m2; and\na Class 9b building which is a theatre.","st":"TAS","base":"E1P7","g":"/ncc/tas-e1p7"},{"c":"TAS E1D1","t":"Deemed-to-Satisfy Provisions","p":"TAS Part E1 Fire fighting equipment","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-e1-fire-fighting-equipment#_7bb74aff-4a9e-4430-825f-30e25c0e4b71","x":"Delete clause E1D1 and insert TAS E1D1 as follows:\nPerformance Requirements E1P1 to E1P6 and TAS E1P7 are satisfied by complying with E1D2 to E1D16, TAS E1D17, and for farm buildings and farm sheds, Part I3.","st":"TAS","base":"E1D1","g":"/ncc/tas-e1d1"},{"c":"TAS E1D17","t":"Fire detection and alarm system","p":"TAS Part E1 Fire fighting equipment","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-e1-fire-fighting-equipment#_561c53d0-315d-4d46-a70d-3d03548f17a3","x":"Insert TAS clause E1D17 in clause E1D17 as follows:\nAn automatic fire detection and alarm system must comply with S20C4 and S20C8.","st":"TAS","base":"E1D17","g":"/ncc/tas-e1d17"},{"c":"TAS F4D4","t":"Facilities in Class 3 to 9 buildings","p":"TAS Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-f4-sanitary-and-other-facilities#_32d63d75-80c3-4426-ab17-e54d640bae35","x":"Delete clause F4D4 and insert TAS F4D4 as follows:\nIn Tasmania, clause F4D4 is replaced with clause F4D4 of BCA 2022 Volume One Amendment 2.","st":"TAS","base":"F4D4","g":"/ncc/tas-f4d4"},{"c":"TAS F4D13","t":"Non-flushed urinals","p":"TAS Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-f4-sanitary-and-other-facilities#_9071a565-5237-47f4-8315-3250785ab26b","x":"Insert TAS clause F4D13 in clause F4D13 as follows:\nNon-flushed urinals not connected to a sewerage system must comply with TAS F4D14.","st":"TAS","base":"F4D13","g":"/ncc/tas-f4d13"},{"c":"TAS F4D14","t":"Installation of closet fixtures","p":"TAS Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-f4-sanitary-and-other-facilities#_080daf99-7c79-4322-9cee-c963b36f0542","x":"Insert TAS clause F4D14 in clause F4D14 as follows:\n(1) If a sufficient sewerage system is not available, an authorised alternative means of disposal of sewage may be installed.\n(2) If sanitary facilities are not water-flushed, the following provisions apply:\nA pit latrine, an incinerating toilet, a chemical toilet, a removable pan or a non-flushing urinal must not be within 2 m of a building containing habitable rooms.\nThe floor on which a removable pan is placed must be impervious.\nA room containing a composting toilet must be separated from habitable rooms by way of a permanently ventilated air lock (which may be a circulation space).\nThe minimum ventilation required under (c) shall be the greater of—\n8000 mm2; or\n1/500th of the floor area of the circulation space.\nAccess for maintenance or removal of waste from a composting toilet must be by way of an access door which opens directly to the outside of the building.","st":"TAS","base":"F4D14","g":"/ncc/tas-f4d14"},{"c":"TAS F8P1","t":"Condensation and water vapour management","p":"TAS Part F8 Condensation management","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-f8-condensation-management#_fdce3aaf-5bbe-4d38-a465-b3f2b8c1b3ba","x":"Delete clause F8P1 and insert TAS F8P1 as follows:\nIn a sole-occupancy unit of a Class 2 building or a Class 4 part of a building, risks associated with water vapour and condensation must be managed to minimise their impact on the health of occupants.\nNotes\nRefer to the guidance in the “Condensation in Buildings Tasmanian Designers’ Guide” – current version available at www.cbos.tas.gov.au. This Guide must be read in conjunction with the NCC.\nThe strategies listed in the Guide exceed the NCC requirements for condensation management, however are strongly recommended to assist in minimising condensation in cool climates like Tasmania.","st":"TAS","base":"F8P1","g":"/ncc/tas-f8p1"},{"c":"TAS G1P2","t":"Swimming pool access and water recirculation systems","p":"TAS Part G1 Minor structures and components","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-g1-minor-structures-and-components#_b4b911f8-f872-4791-9128-67dbf2d013d3","x":"Delete clause G1P2 and insert TAS G1P2 as follows:\n(1) A barrier must be provided to a swimming pool and must—\nbe continuous for the full extent of the hazard; and\nbe of a strength and rigidity to withstand the foreseeable impact of people; and\nrestrict the access of young children to the pool and the immediate pool surrounds; and\nhave any gates and doors fitted with latching devices not readily operated by young children, and constructed to automatically close and latch.\n(2) A swimming pool water recirculation system must incorporate safety measures to avoid entrapment of, or injury to, a person.\nApplications\nTAS G1P2(1) only applies to a swimming pool associated with a Class 2 or 3 building or Class 4 part of a building, with a depth of water of more than 300 mm.\nTAS G1P2(2) only applies to a swimming pool with a depth of water more than 300 mm.","st":"TAS","base":"G1P2","g":"/ncc/tas-g1p2"},{"c":"TAS G1P6","t":"Swimming pools","p":"TAS Part G1 Minor structures and components","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-g1-minor-structures-and-components#_8b1da94f-a1de-4765-9e03-a3d7897d9a99","x":"Insert TAS clause G1P6 in clause G1P6 as follows:\nSwimming pools must be suitable and safe to use and be provided with appropriate facilities.\nLimitations\nTAS G1P6 does not apply to a swimming pool associated with a Class 2 building.","st":"TAS","base":"G1P6","g":"/ncc/tas-g1p6"},{"c":"TAS G1D1","t":"Deemed-to-Satisfy Provisions","p":"TAS Part G1 Minor structures and components","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-g1-minor-structures-and-components#_f3dd050a-aeab-4829-ad8b-1ebfd900ee7e","x":"Delete subclause G1D1(1) and insert TAS G1D1(1) as follows:\n(2) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements G1P2 to G1P5 and TAS G1P6 are satisfied by complying with TAS G1D2 to G1D4.","st":"TAS","base":"G1D1","g":"/ncc/tas-g1d1"},{"c":"TAS G1D2","t":"Swimming pools","p":"TAS Part G1 Minor structures and components","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-g1-minor-structures-and-components#_eb0c5265-b213-4eb0-ad0f-53a5aae462f5","x":"Delete clause G1D2 and insert TAS G1D2 as follows:\n(1) A swimming pool with a depth of water more than 300 mm and which is associated with a Class 2 or 3 building or Class 4 part of a building, must have suitable barriers to restrict access by young children to the immediate pool surrounds in accordance with AS 1926.1 and AS 1926.2.\n(2) A water recirculation system in a swimming pool with a depth of water more than 300 mm must comply with AS 1926.3.\n(3) Swimming pools for the use of the public, a club, or an association, or in connection with Class 3, 5, 6, 7, 8 or 9 buildings must—\nbe constructed of durable materials with smooth finishes; and\nhave sides vertical; and\nin that part of the pool where the water depth is not more than 1.5 m, have the bottom or floor slope not steeper than 1 vertical to 15 horizontal; and\nhave the depth of water marked clearly and conspicuously on each side of the pool (at the shallow end and at the deep end); and\nnot have diving boards installed where the water depth is less than 3.5 m; and\nhave scum-gutters with opening not less than 150 mm if they are to provide hand-holds; and\nhave the floor or bottom of the pool, except for the guide lines, of such colours that the light reflectance is not less than 60%.\n(4) For a public swimming pool or pool in which competitions are held—\nall steps into the pool must be recessed; and\nfittings must not project into the water area; and\npiping must not be bracketed to the sides to provide hand-holds; and\nsurrounding concourses must be provided not less than 2 m wide, with a suitable non-slip surface, graded away from the pool and drained to waste; and\ndressing rooms with sanitary accommodation must be so located that bathers pass through that accommodation enroute to the swimming pool.\n(5) If the volume of a swimming pool exceeds 15 m3—\nan adequate water recirculation, disinfection and filtration system must be installed; and\n(the inlet and outlet openings in a swimming pool for the purpose of water recirculation must be so located that water movement is continuous from inlet to outlet; and\nrecirculation of water in a swimming pool must be so designed that the pool contents are recirculated not less than once in the period shown in TAS Table G1D2a; and\nwater filtration rates must not exceed 12 250 L/m2 of sand filter bed per hour, or an equivalent rate in other filter media.\n(6) Where no other suitable sanitary accommodation is provided, sanitary facilities must be provided in accordance with TAS Table G1D2b.\n(7) Where no other suitable shower facilities are provided, showers must be provided so that each shower serves up to 40 persons.\nInsert TAS table (G1D2a) G1D2 as follows:\nTAS Table G1D2a: Recirculation of water in swimming pools\nPool type\nPeriod (hours)\nOutdoor swimming pool\n6\nIndoor swimming pool\n4\nWading pool\n2\nInsert TAS table (G1D2b) G1D2 as follows:\nTAS Table G1D2b: Sanitary facilities at swimming pools\nGender\nMaximum number served by 1 closet fixture\nMaximum number served by each extra closet fixture\nMaximum number served by 1 urinal\nMaximum number served by each extra urinal\nMaximum number served by 1 wash basin\nMaximum number served by each extra wash basin\nMales\n60\n60\n60\n60\n60\n60\nFemales\n40\n40\nN/A\nN/A\n60\n60","st":"TAS","base":"G1D2","g":"/ncc/tas-g1d2"},{"c":"TAS G5P1","t":"Bushfire resistance","p":"TAS Part G5 Construction in bushfire prone areas","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-g5-construction-bushfire-prone-areas#_bb59ab05-988a-4e27-9261-9c80fa1b0099","x":"Delete clause G5P1 and insert TAS G5P1 as follows:\nA building that is constructed in a designated bushfire prone area must be designed and constructed to—\nreduce the risk of ignition from a design bushfire with an annual exceedance probability not more than 1:100 years, or 1:200 years for a Class 9 building; and\ntake account of the assessed duration and intensity of the fire actions of the design bushfire; and\nbe designed to prevent internal ignition of the building and its contents; and\nmaintain the structural integrity of the building for the duration of the design bushfire.\nApplications\nG5P1 applies in a designated bushfire prone area to—\na Class 2 or 3 building; and\na Class 9a health-care building; and\na Class 9b—\nearly childhood centre; and\nprimary or secondary school; and\na Class 9c residential care building; and\na Class 10a building or deck immediately adjacent or connected to a building of a type listed in (a) to (d).\nNotes\nFor additional requirements relating to bushfire prone areas, refer to the Director’s Determinations on Bushfire Hazard Areas – current versions available at www.cbos.tas.gov.au","st":"TAS","base":"G5P1","g":"/ncc/tas-g5p1"},{"c":"TAS G5P2","t":"Additional bushfire requirements for certain Class 9 buildings","p":"TAS Part G5 Construction in bushfire prone areas","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-g5-construction-bushfire-prone-areas#_72d7953b-a03b-433a-8385-2546bdb9ad21","x":"Delete clause G5P2 and insert TAS G5P2 as follows:\nA building that is constructed in a designated bushfire prone area and occupied by people who may be unable to readily evacuate the building prior to a bushfire must, to the degree necessary—\nreduce the risk of an untenable indoor environment for occupants during a bushfire event, appropriate to the—\nlocation of the building relative to fire hazards, including—\nclassified vegetation; and\nadjacent buildings, structures and movable objects; and\ncarparking areas and allotment boundaries; and\nother combustible materials; and\nnumber of occupants to be accommodated within the building; and\nintensity of bushfire attack on the building; and\nduration of occupancy; and\nintensity of potential consequential fires; and\noccupant tenability within the building before, during and after the bushfire event; and\ncombined effects of structural, fire exposure and other effects to which the building may reasonably be subjected; and\nprovision of fire fighting equipment and water supply to facilitate protection of the building; and\nbe provided with vehicular access to the site to enable firefighting and emergency personnel to defend or evacuate the building; and\nhave access to a sufficient supply of water for firefighting purposes on the site; and\nprovide safe access within the site to the building (including carparking areas), as well as safe egress after the bushfire event.\nApplications\nTAS G5P2 applies to the following buildings located in a designated bushfire prone area —\na Class 9a health-care building; and\na Class 9b—\nearly childhood centre; and\nprimary or secondary school; and\na Class 9c residential care building.\nNotes\nTAS G5P2 does not guarantee the safety of building occupants or the maintenance of tenable conditions within a building during a bushfire event.\nFor additional requirements relating to bushfire prone areas, refer to the Director’s Determinations on Bushfire Hazard Areas – current versions available at www.cbos.tas.gov.au","st":"TAS","base":"G5P2","g":"/ncc/tas-g5p2"},{"c":"TAS I10D1","t":"Application of Part","p":"TAS Part I10 Mortuaries","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i10-mortuaries#_f32e8c90-a8d2-4d92-9865-1db4214d2aff","x":"Delete clause I10D1 and insert TAS I10D1 as follows:\n(1) This Part applies to any premises used for the storage or preparation for burial, cremation or disposal by other means, of bodies of deceased persons.\n(2) Mortuaries must be constructed in a manner that will ensure the health of staff and the general public.","st":"TAS","base":"I10D1","g":"/ncc/tas-i10d1"},{"c":"TAS I10D2","t":"Layout of mortuary","p":"TAS Part I10 Mortuaries","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i10-mortuaries#_6170e742-bea2-49ca-b756-3138e1d15ceb","x":"Delete clause I10D2 and insert TAS I10D2 as follows:\n(1) A mortuary may be integral with the remainder of a building but must be separated physically from all public areas of that building.\n(2) Each mortuary at which bodies are prepared for burial, cremation or other disposal must be provided with a body preparation room—\ncapable of being isolated from the remainder of the premises; and\nhaving a floor area not less than 10m2.\n(3) A vehicle reception area or garage must be provided adjacent to and with direct access to the storage room or body preparation room to ensure that the transfer of uncoffined bodies is screened from public view.\n(4) Access to toilet and shower facilities from any other part of the mortuary premises must be only by way of an air lock.","st":"TAS","base":"I10D2","g":"/ncc/tas-i10d2"},{"c":"TAS I10D3","t":"Construction of body preparation room","p":"TAS Part I10 Mortuaries","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i10-mortuaries#_0b630272-a5c2-4868-b118-928025db94f6","x":"Delete clause I10D3 and insert TAS I10D3 as follows:\n(1) The floor must be—\nof impervious material with a smooth, unbroken surface; and\nuniformly graded to a floor drain.\n(2) All walls and partitions must be of concrete or masonry with a smooth, unbroken finish for ease of cleaning.\n(3) All joints between the floor, walls, partitions, ceiling, ventilation grilles, fittings, pipework, windows and light fittings must be sealed with impervious material for ease of cleaning.\n(4) All joints between the floor and walls or partitions must be coved for ease of cleaning.\n(5) The body preparation room must be provided with at least one washbasin, fitting with elbow or foot-operated taps, and an adequate supply of hot and cold water.\n(6) The body preparation room must be provided with refrigerated storage facilities—\nWith sufficient capacity for the storage of at least two adult bodies; and\nCapable of maintaining an internal temperature between 1°C and 5°C.","st":"TAS","base":"I10D3","g":"/ncc/tas-i10d3"},{"c":"TAS I10D4","t":"Water supply and sewerage","p":"TAS Part I10 Mortuaries","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i10-mortuaries#_b7d3f7ff-9479-48b4-b308-f1513a97d313","x":"Delete clause I10D4 and insert TAS I10D4 as follows:\nEach mortuary with a body preparation room must be connected to—\na permanent water supply with a physical discontinuity, provided by a registered break tank or reduced pressure zone device, between the water supply and all equipment, appliances, fittings and areas in the mortuary; and\na water carriage sewerage system.","st":"TAS","base":"I10D4","g":"/ncc/tas-i10d4"},{"c":"TAS I11D1","t":"Application of Part","p":"TAS Part I11 Foundries","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i11-foundries#_ca6bf620-88fe-42b3-ad61-74e86ef63a47","x":"Delete clause I11D1 and insert TAS I11D1 as follows:\n(1) This Part is applicable to every building or premises on which foundry operations are undertaken.\n(2) Foundries must provide for the comfort and safety of workers on the premises.","st":"TAS","base":"I11D1","g":"/ncc/tas-i11d1"},{"c":"TAS I11D2","t":"General","p":"TAS Part I11 Foundries","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i11-foundries#_faa38db7-e9ab-4155-8560-a5c09497eab6","x":"Delete clause I11D2 and insert TAS I11D2 as follows:\n(1) Every floor in a foundry must be level and, in places other than where molten metal is poured, must be composed or similar material or wooden blocks.\n(2) Every part of a foundry must be not less than 4.2 m high—\nwhere a ceiling is provided, measured from the floor to the ceiling; or\nwhere a ceiling is not provided, measured from the floor to the lowest part of the roof.","st":"TAS","base":"I11D2","g":"/ncc/tas-i11d2"},{"c":"TAS I11D3","t":"Cupola charging platform","p":"TAS Part I11 Foundries","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i11-foundries#_75a404a0-4b99-4ace-ac0a-babe8b1fe435","x":"Delete clause I11D3 and insert TAS I11D3 as follows:\n(1) The floors of cupola charging platforms must be—\nof heavy timber or non-slip steel plate; and\nsecurely fixed in position; and\nlevel.\n(2) All parts of the cupola charging platform must be covered by a roof not less than 3 m above the platform.\n(3) A cupola charging platform must have—\na wall, not less than 1 m high, measured from the floor of the platform, constructed to surround the platform; and\nthe side between the top of the wall and the roof suitably waterproofed an ventilated.\n(4) A properly constructed access stair or ramp must be provide to give access to every cupola charging platform and must comply with AS 1657.","st":"TAS","base":"I11D3","g":"/ncc/tas-i11d3"},{"c":"TAS I11D4","t":"Deep moulds and pits","p":"TAS Part I11 Foundries","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i11-foundries#_aa30e449-6625-4e7e-910b-89f926bf3ab3","x":"Delete clause I11D4 and insert TAS I11D4 as follows:\nDeep moulds or pits, for permanent use—\nmust be lined with bricks, concrete, or other suitable material in such a manner as to provide adequate reinforcement and to keep the pit or mould in a dry condition; and\nmust be securely fenced by means of a wall of adequate construction, railings or chains and stanchions raised, in each case, to a height not less than 1 m above the surface of the surrounding floor.","st":"TAS","base":"I11D4","g":"/ncc/tas-i11d4"},{"c":"TAS I11D5","t":"Pot furnaces","p":"TAS Part I11 Foundries","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i11-foundries#_6449a214-271c-43bc-8be2-071c7a760f8d","x":"Delete clause I11D5 and insert TAS I11D5 as follows:\nWhere pot furnaces are below ground level, the pit must be covered by a substantial grating at the point at which metal is removed from the furnace, and must at all other times be securely fenced as in TAS I11D4(b)","st":"TAS","base":"I11D5","g":"/ncc/tas-i11d5"},{"c":"TAS I11D6","t":"Hand laminating and spray depositing","p":"TAS Part I11 Foundries","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i11-foundries#_0da9ca9a-609b-45ad-803b-8863bfe5c0e7","x":"Delete clause I11D6 and insert TAS I11D6 as follows:\nThe walls and floors of areas to be used for hand laminating and spray depositing must be constructed of non-combustible materials.","st":"TAS","base":"I11D6","g":"/ncc/tas-i11d6"},{"c":"TAS I12D1","t":"Application of Part","p":"TAS Part I12 Premises for manufacture or processing of glass reinforced plastics","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i12-premises-manufacture-or-processing-glass-reinforced-plastics#_bd28fb89-e52c-4791-b296-dc55a574053d","x":"Delete clause I12D1 and insert TAS I12D1 as follows:\n(1) This Part is applicable to every building in which glass reinforced plastics are manufactured or processed.\n(2) Premises for manufacture or processing of glass reinforced plastic must—\nprovide for the safety and comfort or workers; and\nbe constructed in a manner that will avoid the spread of fire within the building and to other buildings.","st":"TAS","base":"I12D1","g":"/ncc/tas-i12d1"},{"c":"TAS I12D2","t":"Separation from other buildings","p":"TAS Part I12 Premises for manufacture or processing of glass reinforced plastics","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i12-premises-manufacture-or-processing-glass-reinforced-plastics#_9cc73ef5-a6c0-4a54-b7bc-c0094b4e0666","x":"Delete clause I12D2 and insert TAS I12D2 as follows:\nA building for the manufacture or processing of glass reinforced plastics must be—\nseparated from other buildings or parts of an occupancy by means of impervious walls with FRL at least 120/120/120; or\nseparated from all other buildings by a clear space of not less than 6 m.","st":"TAS","base":"I12D2","g":"/ncc/tas-i12d2"},{"c":"TAS I12D3","t":"Rise in storeys","p":"TAS Part I12 Premises for manufacture or processing of glass reinforced plastics","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i12-premises-manufacture-or-processing-glass-reinforced-plastics#_6712b7dc-f9e8-4904-aa64-78af8b31745e","x":"Delete clause I12D3 and insert TAS I12D3 as follows:\nThe building must be of single storey construction.","st":"TAS","base":"I12D3","g":"/ncc/tas-i12d3"},{"c":"TAS I12D4","t":"Maximum floor areas","p":"TAS Part I12 Premises for manufacture or processing of glass reinforced plastics","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i12-premises-manufacture-or-processing-glass-reinforced-plastics#_a0b48e44-9dfd-4421-b4d2-af11649dd46e","x":"Delete clause I12D4 and insert TAS I12D4 as follows:\nThe floor area of any building or fire-separated section must not exceed the relevant maximum floor area set out in Table TAS I12D4.\nInsert TAS table (I12D4) I12D4 as follows:\nTAS Table I12D4: Maximum floor area of buildings for manufacture or processing of glass reinforced plastics or isocyanates\nType A building construction\nType B building construction\nType C building construction\nNot sprinklered: 1500 m2\nNot sprinklered: 1200 m2\nNot sprinklered: 1000 m2\nSprinklered: 6000 m2\nSprinklered: 5000 m2\nSprinklered: 3000 m2","st":"TAS","base":"I12D4","g":"/ncc/tas-i12d4"},{"c":"TAS I12D5","t":"Required exits","p":"TAS Part I12 Premises for manufacture or processing of glass reinforced plastics","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i12-premises-manufacture-or-processing-glass-reinforced-plastics#_d71a9cd2-d7f8-46fe-9c55-29094b04e664","x":"Delete clause I12D5 and insert TAS I12D5 as follows:\n(1) Each fire-separated section of a building which is a work place must have at least two exits for escape purposes and the number and location of exits must be such that any point on the floor is not further than 20 m from one of the exits.\n(2) Only exits with vertically hinged swinging doors may be considered as exits for the purposes of this clause.","st":"TAS","base":"I12D5","g":"/ncc/tas-i12d5"},{"c":"TAS I12D7","t":"Ventilation","p":"TAS Part I12 Premises for manufacture or processing of glass reinforced plastics","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i12-premises-manufacture-or-processing-glass-reinforced-plastics#_646a2e49-f938-4615-b319-64074bc3813a","x":"Delete clause I12D7 and insert TAS I12D7 as follows:\n(1) Mechanical or natural ventilation must be via low-level, exhaust ducting in a wall and a fixed, open, floor-level, fresh-air inlet ducting in the opposite wall such as to ensure a cross flow of the ventilation over the complete working area.\n(2) Mechanical ventilation must provide not less than 6 air changes per hour.\n(3) The ventilation fan and exhaust ducting must be arranged in such a manner as to—\nproduce a negative pressure within any exhaust ducting within the work place so that a leak in the ducting will not vent exhaust air back in to the work place; and\nvent the exhaust air to the atmosphere so as to prevent recirculation of that exhaust air.","st":"TAS","base":"I12D7","g":"/ncc/tas-i12d7"},{"c":"TAS I12D8","t":"Smoke and heat roof vents","p":"TAS Part I12 Premises for manufacture or processing of glass reinforced plastics","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i12-premises-manufacture-or-processing-glass-reinforced-plastics#_d58e942a-be84-4b42-b579-519ef815b0fd","x":"Delete clause I12D8 and insert TAS I12D8 as follows:\nEach fire-separated section must be provided with automatic smoke and heat roof vents.","st":"TAS","base":"I12D8","g":"/ncc/tas-i12d8"},{"c":"TAS I13D1","t":"Application of Part","p":"TAS Part I13 Premises for production of processing of isocyanates","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i13-premises-production-processing-isocyanates#_2849527d-56d7-4cbb-b555-52aaacbb131d","x":"Delete clause I13D1 and insert TAS I13D1 as follows:\n(1) This Part is applicable to every building in which isocyanate production or processing is undertaken.\n(2) Premises for production or processing of isocyanates must—\nprovide for the safety and comfort of workers; and\nbe constructed in a manner that will avoid the spread of fire within the building and to other buildings.","st":"TAS","base":"I13D1","g":"/ncc/tas-i13d1"},{"c":"TAS I13D2","t":"Areas of work places","p":"TAS Part I13 Premises for production of processing of isocyanates","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i13-premises-production-processing-isocyanates#_39510e46-f7b5-4515-ba68-67dfd8838dca","x":"Delete clause I13D2 and insert TAS I13D2 as follows:\nWork places in which an isocyanate industry is carried out must be divided into the following divisional areas:\nAdministration and staff amenities.\nWorkshop.\nBulk stores.\nCuring room.\nProcessing plant.\nRaw materials plant.\nManufacture.","st":"TAS","base":"I13D2","g":"/ncc/tas-i13d2"},{"c":"TAS I13D3","t":"Separation from other areas and buildings","p":"TAS Part I13 Premises for production of processing of isocyanates","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i13-premises-production-processing-isocyanates#_39e90db4-252c-44b3-ba5f-50d46c598c93","x":"Delete clause I13D3 and insert TAS I13D3 as follows:\n(1) Each of the divisional areas required by TAS I13D2 other than the administration and staff amenities building, must be—\nseparated from each of the other divisional areas by means of an impervious wall with an FRL of not less than 120/120/120; or\nseparated from all other buildings by a clear space of not less than 6 m.\n(2) Notwithstanding the distance requirements of (1), bulk stores of polyols and bulk stores of isocyanates must comply with the requirements of the Work Health and Safety Act.","st":"TAS","base":"I13D3","g":"/ncc/tas-i13d3"},{"c":"TAS I13D4","t":"Rise in storeys","p":"TAS Part I13 Premises for production of processing of isocyanates","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i13-premises-production-processing-isocyanates#_58801804-ff49-4e5e-8f54-02fc48a12991","x":"Delete clause I13D4 and insert TAS I13D4 as follows:\nThe building must be of single storey construction.","st":"TAS","base":"I13D4","g":"/ncc/tas-i13d4"},{"c":"TAS I13D5","t":"Maximum floor areas","p":"TAS Part I13 Premises for production of processing of isocyanates","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i13-premises-production-processing-isocyanates#_70ed563c-19ac-466d-9c75-aa47f74d8422","x":"Delete clause I13D5 and insert TAS I13D5 as follows:\nThe floor area of any building or fire-separated section must not exceed the area shown in Table TAS I12D4.","st":"TAS","base":"I13D5","g":"/ncc/tas-i13d5"},{"c":"TAS I13D6","t":"Required exits","p":"TAS Part I13 Premises for production of processing of isocyanates","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i13-premises-production-processing-isocyanates#_64bb0a3a-fbb6-4654-bd5e-29f493d77d6b","x":"Delete clause I13D6 and insert TAS I13D6 as follows:\n(1) Every building and divisional area of a work place must have not less than 2 exits for escape purposes.\n(2) The number and location of the exits must be such that any point on the floor is not more than 20 m from one of the exits.\n(3) Only exits with vertically hinged swinging doors may be considered as exits for the purposes of this clause.","st":"TAS","base":"I13D6","g":"/ncc/tas-i13d6"},{"c":"TAS I13D7","t":"Bulk stores for polyols and isocyanates","p":"TAS Part I13 Premises for production of processing of isocyanates","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i13-premises-production-processing-isocyanates#_d5d10039-58e4-4d11-9441-6f874dad6957","x":"Delete clause I13D7 and insert TAS I13D7 as follows:\n(1) A bulk store for polyols must be constructed from non-combustible materials and have a smooth impervious concrete floor and it must protect the polyols from direct exposure to the sun’s radiation.\n(2) A bulk store for isocyanates must—\nbe constructed from non-combustible materials, have a smooth impervious concrete floor, and must protect the isocyanate containers from direct exposure to the sun; and\nif it is used for the storage of either TDI or HDI and is not an open sided building, be fitted with mechanical ventilation so that the TLV is not exceeded at any time provided that the ventilation must provide not less than 6 air changes per hour.\n(3) The area around both a polyol bulk store and an isocyanate bulk store must be bunded, the bund or bunds must ensure separation of the polyol and isocyanate areas and each bund must have a capacity of 10% more than the storage capacity of the largest tank it protects.","st":"TAS","base":"I13D7","g":"/ncc/tas-i13d7"},{"c":"TAS I13D8","t":"Curing room","p":"TAS Part I13 Premises for production of processing of isocyanates","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i13-premises-production-processing-isocyanates#_0d8b34a6-6826-434c-849e-ee6815d56e7d","x":"Delete clause I13D8 and insert TAS I13D8 as follows:\nThe curing room for the storage of newly produced flexible polyurethane foam must be constructed of non-combustible materials with a smooth impervious concrete floor and fitted automatic fire vents in the roof.","st":"TAS","base":"I13D8","g":"/ncc/tas-i13d8"},{"c":"TAS I14D1","t":"Application of Part","p":"TAS Part I14 Premises for electro-plating, electro-polishing, anodising or etching","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i14-premises-electro-plating-electro-polishing-anodising-or-etching#_ce36c5fb-8152-4b7f-810a-f31420fc3047","x":"Delete clause I14D1 and insert TAS I14D1 as follows:\n(1) This Part is applicable to every building where any of the processes of electro-plating, electro-polishing, anodising or etching are undertaken.\n(2) Premises for electro-plating, electro-polishing, anodising or etching must—\nprovide for the safety and comfort of workers; and\nbe constructed in a manner that will prevent the escape of liquids and atmospheric contaminants to other areas of the building.","st":"TAS","base":"I14D1","g":"/ncc/tas-i14d1"},{"c":"TAS I14D2","t":"Floors","p":"TAS Part I14 Premises for electro-plating, electro-polishing, anodising or etching","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i14-premises-electro-plating-electro-polishing-anodising-or-etching#_7657306c-9d30-42f2-bb1b-750576c01ec6","x":"Delete clause I14D2 and insert TAS I14D2 as follows:\nThe floor of every plating area must be—\nso graded as to—\npermit easy flushing with water; and\nprevent liquids from flowing from the area into other parts or the work place; and\nchemically resistant to the solutions used in the process.","st":"TAS","base":"I14D2","g":"/ncc/tas-i14d2"},{"c":"TAS I14D3","t":"Height of plating area","p":"TAS Part I14 Premises for electro-plating, electro-polishing, anodising or etching","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i14-premises-electro-plating-electro-polishing-anodising-or-etching#_c8c195c0-5cea-4854-bff0-3f4d2203fddc","x":"Delete clause I14D3 and insert TAS I14D3 as follows:\nEvery part of a plating area must be not less than 2.7 m in height—\nmeasured from the floor to the ceiling if a ceiling is provided; or\nmeasured from the floor to the lowest part of the roof if a ceiling is not provided.","st":"TAS","base":"I14D3","g":"/ncc/tas-i14d3"},{"c":"TAS I14D4","t":"Air space","p":"TAS Part I14 Premises for electro-plating, electro-polishing, anodising or etching","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i14-premises-electro-plating-electro-polishing-anodising-or-etching#_efacad5e-0d8f-450c-ab04-e0561ccf0791","x":"Delete clause I14D4 and insert TAS I14D4 as follows:\nIn every plating area there must be not less than 14 m3 of air space for each person employed and, in the calculation of such space, the height taken into account must not exceed 4.2 m.","st":"TAS","base":"I14D4","g":"/ncc/tas-i14d4"},{"c":"TAS I14D5","t":"Ceiling construction","p":"TAS Part I14 Premises for electro-plating, electro-polishing, anodising or etching","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i14-premises-electro-plating-electro-polishing-anodising-or-etching#_89c6cabb-8fde-4c6c-bd91-7886ead37544","x":"Delete clause I14D5 and insert TAS I14D5 as follows:\nThe ceiling of a plating area must be so constructed as to prevent, so far as is practicable, atmospheric contaminants from escaping into rooms or work places, situated above the level of the ceiling.","st":"TAS","base":"I14D5","g":"/ncc/tas-i14d5"},{"c":"TAS I15D1","t":"Application of Part","p":"TAS Part I15 Premises for lead processing","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i15-premises-lead-processing#_d07167af-e977-4a53-9912-adb42625c8a6","x":"Delete clause I15D1 and insert TAS I15D1 as follows:\n(1) This Part is applicable to every building in which lead processes are used.\n(2) Premises used for lead processing must—\nprovide for the safety and comfort of workers; and\nbe constructed in a manner that will minimise the lodgement of dust and must be capable of being flushed with water.","st":"TAS","base":"I15D1","g":"/ncc/tas-i15d1"},{"c":"TAS I15D2","t":"Floors","p":"TAS Part I15 Premises for lead processing","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i15-premises-lead-processing#_0cce8a77-deff-41c5-a1e2-b09caa2450e2","x":"Delete clause I15D2 and insert TAS I15D2 as follows:\n(1) The floor of every work place where a lead process is used must be—\nso constructed of concrete or other suitable material as to be smooth and impervious to fluids; and\ngraded and properly drained to permit flushing with water.\n(2) The mater of which the floor is constructed must be applied to the walls to a height of not less than 75 mm in such a fashion that the angle between the walls and the floor is coved for easy cleaning.","st":"TAS","base":"I15D2","g":"/ncc/tas-i15d2"},{"c":"TAS I15D3","t":"Height of lead processing areas","p":"TAS Part I15 Premises for lead processing","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i15-premises-lead-processing#_38442ab0-5641-44d9-8123-a53f598e4117","x":"Delete clause I15D3 and insert TAS I15D3 as follows:\nEvery part of a lead processing area must be not less than 2.7 m in height—\nwhere a ceiling is provided, measured from the floor to the ceiling; or\nwhere a ceiling is not provided, measured from the floor to the lowest part of the roof.","st":"TAS","base":"I15D3","g":"/ncc/tas-i15d3"},{"c":"TAS I15D4","t":"Air space and floor space","p":"TAS Part I15 Premises for lead processing","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i15-premises-lead-processing#_c2c29133-7831-4d75-b1f8-2158b3374c2a","x":"Delete clause I15D4 and insert TAS I15D4 as follows:\n(1) In every lead processing area there must be not less than 14 m3 of air space for each person employed therein, and in the calculation of such space the maximum height taken must be not greater than 4.2 m.\n(2) The total floor space for the persons employed in such area, exclusive of space used for storage, must be not less than 3.3 m2 for each person so employed.","st":"TAS","base":"I15D4","g":"/ncc/tas-i15d4"},{"c":"TAS I15D5","t":"Interior of lead processing areas","p":"TAS Part I15 Premises for lead processing","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i15-premises-lead-processing#_bf7ef006-ce62-4243-a165-3df4e79d3bcf","x":"Delete clause I15D5 and insert TAS I15D5 as follows:\n(1) The inner surfaces of the walls of every lead processing area must be of a smooth material impervious to fluids and must not contain any projections on which dust may lodge.\n(2) The interior construction of the ceiling or roof must, so far as is practicable, be such that dust will not settle on it.","st":"TAS","base":"I15D5","g":"/ncc/tas-i15d5"},{"c":"TAS I15D6","t":"Dust collection","p":"TAS Part I15 Premises for lead processing","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i15-premises-lead-processing#_eb152635-8188-4cb9-8ba8-a3dcd6861460","x":"Delete clause I15D6 and insert TAS I15D6 as follows:\nAny areas in which dust-forming lead particles are manipulated, moved or treated must be served by a mechanical exhaust ventilation system capable of safely and effectively collecting all dust.","st":"TAS","base":"I15D6","g":"/ncc/tas-i15d6"},{"c":"TAS I15D7","t":"Isolation of certain processes","p":"TAS Part I15 Premises for lead processing","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i15-premises-lead-processing#_1d9f16b0-4e20-4f2a-a8f5-62384b98aee2","x":"Delete clause I15D7 and insert TAS I15D7 as follows:\nWhere any process of pasting of electric accumulator plates or drying of paste plates, or melting down of pasted plates or of formation with tacking in the electric accumulator industry or of manipulation of dry oxide or lead, is to be carried out in the same room as any other lead process, the process of pasting, drying, melting, formation or manipulation must be isolated from one another and from any other lead process—\nby a partition extending from the floor to the ceiling in the case of a room having a ceiling not more than 3.6 m in height, or to a height of 2.7 m in any other case; or\nby some other suitable method.","st":"TAS","base":"I15D7","g":"/ncc/tas-i15d7"},{"c":"TAS I15D8","t":"Drying room shelves","p":"TAS Part I15 Premises for lead processing","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i15-premises-lead-processing#_92446aca-9b06-4a34-a498-8be80ff3f3f6","x":"Delete clause I15D8 and insert TAS I15D8 as follows:\nThe racks or shelves provided in any drying room must be not more than 2.6 m from the floor nor more than 650 mm in width except that, in the case of racks or shelves set or drawn from both sides, the total width must not exceed 1.3 m.","st":"TAS","base":"I15D8","g":"/ncc/tas-i15d8"},{"c":"TAS I15D9","t":"Washing facilities","p":"TAS Part I15 Premises for lead processing","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i15-premises-lead-processing#_6e040eee-b22d-4d61-94d3-28288f364456","x":"Delete clause I15D9 and insert TAS I15D9 as follows:\nWashing facilities served with running hot and cold water for the use of all employees engaged in a lead process must be provided consisting of—\none washbasin for each 5 employees, or part thereof; and\none shower bath for each 8 employees, or part thereof.","st":"TAS","base":"I15D9","g":"/ncc/tas-i15d9"},{"c":"TAS I15D10","t":"Change rooms","p":"TAS Part I15 Premises for lead processing","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i15-premises-lead-processing#_8f0dd9e6-8bf5-4a34-94f9-22bdca797f12","x":"Delete clause I15D10 and insert TAS I15D10 as follows:\nIn every work place in which lead is processed there must be provided two suitable furnished change rooms for the use of employees as follows—\none of the change rooms must be used for taking off, storing, and putting on of the street clothing of employees; and\nthe other of the change rooms must be used for taking, storing, and putting on of overalls or other clothing work in any work room; and\neach change room must be so constructed and situated as to prevent the entry into the room of dust and fumes generated in a work room; and\neach change room must be in close proximity to the washing facilities required in TAS I15D9.","st":"TAS","base":"I15D10","g":"/ncc/tas-i15d10"},{"c":"TAS I16O1","t":"Objective","p":"TAS Part I16 Early childhood centres and school age care facilities","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i16-early-childhood-centres-and-school-age-care-facilities#_acfbe954-073e-4e72-a2e5-9d9c164eaf9a","x":"Delete clause I16O1 and insert TAS I16O1 as follows:\nThe Objective of this Part is to regulate the physical specification of early childhood centres and school age care facilities at which education and care is provided.","st":"TAS","base":"I16O1","g":"/ncc/tas-i16o1"},{"c":"TAS I16F1","t":"Early childhood centres and school age care facilities","p":"TAS Part I16 Early childhood centres and school age care facilities","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i16-early-childhood-centres-and-school-age-care-facilities#_68cc428a-932f-4729-9a71-cd5dd4ddec15","x":"Delete clause I16F1 and insert TAS I16F1 as follows:\nAn early childhood centre and school age care facility must be designed and constructed to provide a safe environment and provide for the health, safety and well-being of the children, parents and staff using the centre.","st":"TAS","base":"I16F1","g":"/ncc/tas-i16f1"},{"c":"TAS I16P1","t":"Design and construction","p":"TAS Part I16 Early childhood centres and school age care facilities","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i16-early-childhood-centres-and-school-age-care-facilities#_0bc2d6d9-1203-4c4e-89a1-bd477ebde6d6","x":"Delete clause I16P1 and insert TAS I16P1 as follows:\nThe design and construction of an early childhood centre and school age care facility must to the degree necessary, provide an environment that is spacious enough to prevent overcrowding, and supports a range of daily activities and routines including—\nindoor playing; and\noutdoor playing; and\nsleeping.\nApplications\nTAS I16P1 applies to early childhood centres and school age care facilities approved under the Education and Care Services National Law (Application) Act 2011 or licensed under the Child Care Act 2001.","st":"TAS","base":"I16P1","g":"/ncc/tas-i16p1"},{"c":"TAS I16P2","t":"Health and amenity","p":"TAS Part I16 Early childhood centres and school age care facilities","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i16-early-childhood-centres-and-school-age-care-facilities#_d64195e7-008e-4490-88f8-7c93e1ecb08a","x":"Delete clause I16P2 and insert TAS I16P2 as follows:\nAn early childhood centre and school age care facility, must to the degree necessary, have sufficient space and facilities to ensure a healthy, safe and comfortable environment for children, staff and parents including—\nsanitary facilities; and\nnappy changing facilities; and\nlaundry facilities; and\nfood preparation facilities; and\nreception, administration and staff facilities; and\nstorage facilities; and\nsuitable—\nfloor surfaces; and\nlighting and ventilation; and\nfire safety provisions; and\nwindows and glazing; and\nheating and cooling.\nApplications\nTAS I16P2 applies to early childhood centres and school age care facilities approved under the Education and Care Services National Law (Application) Act 2011 or licensed under the Child Care Act 2001.","st":"TAS","base":"I16P2","g":"/ncc/tas-i16p2"},{"c":"TAS I16P3","t":"Perimeter fencing and barriers","p":"TAS Part I16 Early childhood centres and school age care facilities","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i16-early-childhood-centres-and-school-age-care-facilities#_a4dd709b-04d7-45c7-bc64-33df1330727a","x":"Delete clause I16P3 and insert TAS I16P3 as follows:\nAn early childhood centre and school age care facility must to the degree necessary, have fencing around the perimeter of any outdoor play space, and any identified hazard isolated by fences, barriers and gates.\nApplications\nTAS I16P3 applies to early childhood centres and school age care facilities approved under the Education and Care Services National Law (Application) Act 2011 or licensed under the Child Care Act 2001.","st":"TAS","base":"I16P3","g":"/ncc/tas-i16p3"},{"c":"TAS I16D1","t":"Application of Part","p":"TAS Part I16 Early childhood centres and school age care facilities","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i16-early-childhood-centres-and-school-age-care-facilities#_335a4c06-15b4-420c-81a0-82f1c0ad9097","x":"Delete clause I16D1 and insert TAS I16D1 as follows:\nThis Part applies to early childhood centres and school age care facilities approved under the Education and Care Services National Law (Application) Act 2011 or licensed under the Child Care Act 2001.","st":"TAS","base":"I16D1","g":"/ncc/tas-i16d1"},{"c":"TAS I16D2","t":"Deemed-to-Satisfy Provisions","p":"TAS Part I16 Early childhood centres and school age care facilities","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i16-early-childhood-centres-and-school-age-care-facilities#_5379122f-139a-47cf-b2dd-5928889502b5","x":"Delete clause I16D2 and insert TAS I16D2 as follows:\n(1) Performance Requirement TAS I16P1 is satisfied by complying with the relevant provisions of the Early Childhood Centre and School Age Care Facilities Code.\n(2) Performance Requirement TAS I16P2 is satisfied by complying with the relevant provisions of the Early Childhood Centre and School Age Care Facilities Code.\n(3) Performance Requirement TAS I16P3 is satisfied by complying with the relevant provisions of the Early Childhood Centre and School Age Care Facilities Code.","st":"TAS","base":"I16D2","g":"/ncc/tas-i16d2"},{"c":"TAS I17D1","t":"Application of Part","p":"TAS Part I17 Premises where work is undertaken on gas-fuelled vehicles","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i17-premises-where-work-undertaken-gas-fuelled-vehicles#_2b1b6abc-4adf-4196-ae7a-1970b2d2a8ac","x":"Delete clause I17D1 and insert TAS I17D1 as follows:\nThis Part is applicable to every building where work is undertaken on gas-fuelled vehicles.","st":"TAS","base":"I17D1","g":"/ncc/tas-i17d1"},{"c":"TAS I17D2","t":"Working areas","p":"TAS Part I17 Premises where work is undertaken on gas-fuelled vehicles","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i17-premises-where-work-undertaken-gas-fuelled-vehicles#_551e64e7-79af-4b6d-9615-ddce0ecd517c","x":"Delete clause I17D2 and insert TAS I17D2 as follows:\nThe working area of a building where work is undertaken on a gas-fuelled vehicle is to be designed and constructed to comply with the requirements for premises in AS 2746 Working areas for gas-fuelled vehicles.","st":"TAS","base":"I17D2","g":"/ncc/tas-i17d2"},{"c":"TAS I18P1","t":"Application of Part","p":"TAS Part I18 Temporary structures","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i18-temporary-structures#_566b897a-aac4-40b5-8514-ff86bc32566c","x":"Delete clause I18P1 and insert TAS I18P1 as follows:\nTAS I18P2 to TAS I18P16 only apply to a temporary structure that—\nis used by the public as a place of assembly as described in the Public Health Act 1997; and\nis a temporary structure as described in the Building Act 2016.","st":"TAS","base":"I18P1","g":"/ncc/tas-i18p1"},{"c":"TAS I18P2","t":"Safety and serviceability","p":"TAS Part I18 Temporary structures","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i18-temporary-structures#_a18c70ae-2ea8-42bb-b869-2f886c44fdc9","x":"Delete clause I18P2 and insert TAS I18P2 as follows:\nA temporary structure must, to the degree necessary, be capable of sustaining at an acceptable level of safety and serviceability the most adverse combination of loads and other actions to which it may reasonably be expected to be subjected.","st":"TAS","base":"I18P2","g":"/ncc/tas-i18p2"},{"c":"TAS I18P3","t":"Resistance to the spread of fire","p":"TAS Part I18 Temporary structures","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i18-temporary-structures#_c4c048e1-3cad-4227-aade-f8974aa5e7f0","x":"Delete clause I18P3 and insert TAS I18P3 as follows:\nThe material used in a temporary structure must, to the degree necessary, be capable of resisting the spread of fire to limit the generation of smoke and heat, and any toxic gases likely to be produced.","st":"TAS","base":"I18P3","g":"/ncc/tas-i18p3"},{"c":"TAS I18P4","t":"Access","p":"TAS Part I18 Temporary structures","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i18-temporary-structures#_be3965f8-8aea-4e04-b0be-0907f26df637","x":"Delete clause I18P4 and insert TAS I18P4 as follows:\n(1) Access must be provided, to the degree necessary, to enable safe, equitable and dignified movement of people to and within a temporary structure.\n(2) So that people can move safely to and within a temporary structure, it must have—\nwalking surfaces with safe gradients; and\nstairways and ramps with slip-resistant walking surfaces; and\nsuitable handrails where necessary to assist and provide stability to people using a stairway or ramp.\n(3) Access for people with disabilities must be provided to and within a temporary structure, including to any public sanitary facilities and all areas normally used by the public.\n(4) If fixed seating is provided in a temporary structure, an appropriate number of wheelchair spaces must be provided.","st":"TAS","base":"I18P4","g":"/ncc/tas-i18p4"},{"c":"TAS I18P5","t":"Exits","p":"TAS Part I18 Temporary structures","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i18-temporary-structures#_d44da8bd-8a31-44d5-bb4b-1dddd68eca46","x":"Delete clause I18P5 and insert TAS I18P5 as follows:\n(1) Exits must be provided to the degree necessary, from a temporary structure to enable the safe evacuation of occupants, with their number, location and dimensions being appropriate to the—\ntravel distances to exits; and\nnumber, mobility and other characteristics of the occupants; and\nfunction or use of the structure.\n(2) So that occupants can safely evacuate a temporary structure, paths of travel to exits must have dimensions appropriate to the—\nnumber, mobility and other characteristics of the occupants; and\nfunction or use of the structure.","st":"TAS","base":"I18P5","g":"/ncc/tas-i18p5"},{"c":"TAS I18P6","t":"Fall prevention","p":"TAS Part I18 Temporary structures","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i18-temporary-structures#_4e630697-5b37-422e-9c27-637a6a39c02c","x":"Delete clause I18P6 and insert TAS I18P6 as follows:\nWhere a person could fall 1 m or more, due to a sudden change of level within or associated with a temporary structure, a barrier must to the degree necessary, be provided which must be—\ncontinuous and extend for the full extent of the hazard; and\nof a height to protect people from accidentally falling from the level; and\nconstructed to prevent people falling through the barrier; and\ncapable of restricting the passage of children; and\nof a strength and rigidity to withstand the foreseeable impact of people and where appropriate, the static pressure or people pressing against it.","st":"TAS","base":"I18P6","g":"/ncc/tas-i18p6"},{"c":"TAS I18P7","t":"Lighting","p":"TAS Part I18 Temporary structures","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i18-temporary-structures#_1b8c68b3-934c-4539-a825-47b40f90a9a1","x":"Delete clause I18P7 and insert TAS I18P7 as follows:\nA level of illumination for safe evacuation from a temporary structure in an emergency must be provided, to the degree necessary, appropriate to the—\nfunction or use of the structure; and\nsize of the structure; and\ndistance of travel to an exit.","st":"TAS","base":"I18P7","g":"/ncc/tas-i18p7"},{"c":"TAS I18P8","t":"Identification of exits","p":"TAS Part I18 Temporary structures","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i18-temporary-structures#_2e62c3fc-286e-4f94-9cc9-fca7b69599d9","x":"Delete clause I18P8 and insert TAS I18P8 as follows:\nTo facilitate evacuation from a temporary structure suitable signs or other means of identification must, to the degree necessary—\nbe provided to identify the location of exits; and\nguide the occupants to the exits; and\nbe clearly visible to the occupants; and\noperate in the event of power failure for a sufficient time for occupants to safely evacuate.","st":"TAS","base":"I18P8","g":"/ncc/tas-i18p8"},{"c":"TAS I18P9","t":"Fire-fighting equipment","p":"TAS Part I18 Temporary structures","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i18-temporary-structures#_f759038c-b846-44bd-9a34-c551a26c5e09","x":"Delete clause I18P9 and insert TAS I18P9 as follows:\nFire equipment must be installed in a temporary structure to the degree necessary, to allow the occupants to undertake initial attack on a fire appropriate to the—\nfunction or use of the structure; and\nfire hazard.","st":"TAS","base":"I18P9","g":"/ncc/tas-i18p9"},{"c":"TAS I18P10","t":"Sanitary facilities","p":"TAS Part I18 Temporary structures","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i18-temporary-structures#_1cf02e53-dc23-400f-8d55-c3476050bce9","x":"Delete clause I18P10 and insert TAS I18P10 as follows:\nSanitary facilities for personal hygiene must be provided in a convenient location associated with a temporary structure, to the degree necessary, appropriate to the—\nfunction or use of the structure; and\nnumber and gender of the occupants; and\ndisability or other particular needs of the occupants.","st":"TAS","base":"I18P10","g":"/ncc/tas-i18p10"},{"c":"TAS I18P11","t":"Artificial lighting","p":"TAS Part I18 Temporary structures","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i18-temporary-structures#_fcdec188-d826-40bc-8574-fabc99a13d12","x":"Delete clause I18P11 and insert TAS I18P11 as follows:\n(1) A temporary structure must be provided with natural or artificial lighting to enable the safe use and movement of people using the structure.\n(2) Lighting must be installed to the degree necessary, to provide a level of illumination appropriate to the function or use of a temporary structure to enable safe use and movement by the occupants.","st":"TAS","base":"I18P11","g":"/ncc/tas-i18p11"},{"c":"TAS I18P12","t":"Ventilation","p":"TAS Part I18 Temporary structures","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i18-temporary-structures#_53f5bc7e-7964-4935-a645-cd09e71da2d9","x":"Delete clause I18P12 and insert TAS I18P12 as follows:\n(1) A temporary structure must be provided with a means of ventilation which will maintain adequate air quality.\n(2) Ventilation must be provided to the degree necessary, to a level appropriate to the function or use of a temporary structure.","st":"TAS","base":"I18P12","g":"/ncc/tas-i18p12"},{"c":"TAS I18P13","t":"Electrical services","p":"TAS Part I18 Temporary structures","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i18-temporary-structures#_6f770ecc-1a26-4872-8e2c-f4bd0b0eace4","x":"Delete clause I18P13 and insert TAS I18P13 as follows:\nElectrical services must be installed to the degree necessary, to provide a level of safety appropriate to the environment and function or use of a temporary structure by the occupants.","st":"TAS","base":"I18P13","g":"/ncc/tas-i18p13"},{"c":"TAS I18P14","t":"Heating appliances","p":"TAS Part I18 Temporary structures","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i18-temporary-structures#_5d29079b-91c8-43f4-a098-19bfe198bdd2","x":"Delete clause I18P14 and insert TAS I18P14 as follows:\nWhere provided for a temporary structure, a heating appliance and its associated components must be installed to the degree necessary—\nto withstand the temperatures likely to be generated by the appliance; and\nso that it does not raise the temperature of any structural element to a level that would adversely affect the element’s physical or mechanical properties or function; and\nso that hot products of combustion will not—\nescape through the walls of the associated components; and\ndischarge to a position that will cause fire to spread to nearby combustible materials or allow smoke to penetrate the temporary structure; and\nto reduce the likelihood of fire and harmful emissions spreading beyond the appliance.","st":"TAS","base":"I18P14","g":"/ncc/tas-i18p14"},{"c":"TAS I18P15","t":"Tiered seating","p":"TAS Part I18 Temporary structures","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i18-temporary-structures#_f6517fd4-1177-4f18-860c-97448c563e93","x":"Delete clause I18P15 and insert TAS I18P15 as follows:\nA temporary structure of tiered seating must be designed and constructed to the degree necessary, to provide for the safety of occupants and orderly means of evacuation in an emergency.","st":"TAS","base":"I18P15","g":"/ncc/tas-i18p15"},{"c":"TAS I18P16","t":"Safe environment","p":"TAS Part I18 Temporary structures","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i18-temporary-structures#_d3a83311-6ef1-40b7-b4cd-b4dd01201a85","x":"Delete clause I18P16 and insert TAS I18P16 as follows:\nA temporary structure must, to the degree necessary, be a safe and hazard free environment for the people using the structure.","st":"TAS","base":"I18P16","g":"/ncc/tas-i18p16"},{"c":"TAS I18D1","t":"Application of Part","p":"TAS Part I18 Temporary structures","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i18-temporary-structures#_768ab466-afcb-4be7-91b7-b18cb792b7c0","x":"Delete clause I18D1 and insert TAS I18D1 as follows:\nThis Part only applies to a temporary structure that—\nis used by the public as a place of assembly as described in the Public Health Act 1997; and\nis a temporary structure as described in the Building Act 2016.","st":"TAS","base":"I18D1","g":"/ncc/tas-i18d1"},{"c":"TAS I18D2","t":"Deemed-to-Satisfy Provisions","p":"TAS Part I18 Temporary structures","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i18-temporary-structures#_6af6a5b6-ca55-4c9a-b5b0-75d92b4e60f8","x":"Delete clause I18D2 and insert TAS I18D2 as follows:\nPerformance Requirements TAS I18P1 to TAS I18P16 are satisfied by complying with the provisions of the ABCB Temporary Structures Standard, except for the following:\nDisability access requirements, which are included in TAS I18D3.\nLighting requirements, which are included in TAS I18D4.\nVentilation requirements, which are included in TAS I18D5.\nElectrical requirements, which are included in TAS I18D6.\nHeating appliance requirements, which are included in TAS I18D7.","st":"TAS","base":"I18D2","g":"/ncc/tas-i18d2"},{"c":"TAS I18D3","t":"Access","p":"TAS Part I18 Temporary structures","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i18-temporary-structures#_57354691-6972-4c2f-829c-552ccc3596a2","x":"Delete clause I18D3 and insert TAS I18D3 as follows:\n(1) Access for people with disabilities must be provided to and within a temporary structure by means of a continuous path of travel.\n(2) Access for people with disabilities must be provided to—\nany public sanitary facilities; and\nall areas normally used by the public but excluding those areas only used by persons working in the temporary structure.\n(3) If fixed seating is provided, in a temporary structure, wheelchair spaces must be provided not less than—\n1 wheelchair space for up to 100 seats; and\n2 wheelchair spaces for 100 - 200 seats; and\nan additional wheelchair space for each additional 200 seats or part thereof.\n(4) Parts of a temporary structure required to be accessible must comply with AS 1428.1.","st":"TAS","base":"I18D3","g":"/ncc/tas-i18d3"},{"c":"TAS I18D4","t":"Lighting","p":"TAS Part I18 Temporary structures","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i18-temporary-structures#_579e74f8-6094-424a-9258-4b43d17d3254","x":"Delete clause I18D4 and insert TAS I18D4 as follows:\n(1) Natural or artificial lighting must be provided to all enclosed areas in a temporary structure.\n(2) Natural lighting must as far as practicable be not less than 10% of the floor area of the enclosed area.\n(3) The artificial lighting system must as far as practicable comply with the relevant provisions of AS 1680 Parts 1, 2.0, 2.1, 2.2 and 2.3.","st":"TAS","base":"I18D4","g":"/ncc/tas-i18d4"},{"c":"TAS I18D5","t":"Ventilation","p":"TAS Part I18 Temporary structures","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i18-temporary-structures#_f640440a-4129-431e-8308-5d79ddebfc89","x":"Delete clause I18D5 and insert TAS I18D5 as follows:\n(1) Natural ventilation or mechanical ventilation must be provided to all enclosed areas in a temporary structure.\n(2) Natural ventilation must as far as practicable consist of openings or devices which can be opened with an aggregate opening of not less than 5% of the floor area of the enclosed area.\n(3) Mechanical ventilation must as far as practicable comply with the relevant provisions of AS 1668.2.","st":"TAS","base":"I18D5","g":"/ncc/tas-i18d5"},{"c":"TAS I18D6","t":"Electrical","p":"TAS Part I18 Temporary structures","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i18-temporary-structures#_88e2ad91-df7f-4de7-9f83-c4f2cf61589e","x":"Delete clause I18D6 and insert TAS I18D6 as follows:\nAll electrical installations in a temporary structure must be installed in accordance with AS/NZS 3000.","st":"TAS","base":"I18D6","g":"/ncc/tas-i18d6"},{"c":"TAS I18D7","t":"Heating appliances","p":"TAS Part I18 Temporary structures","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i18-temporary-structures#_9d0deb7b-ac50-4625-8657-ce52b06b0ce4","x":"Delete clause I18D7 and insert TAS I18D7 as follows:\nThe installation of a stove, heater or similar appliance in a temporary structure must as far as practicable comply with the following standards:\nDomestic oil-fired appliances – Installation: AS 1691.\nDomestic solid-fuel burning appliances – Installation: AS/NZS 2918.\nLP gas portable mobile appliances: AS 2658.","st":"TAS","base":"I18D7","g":"/ncc/tas-i18d7"},{"c":"TAS I4O1","t":"Objective","p":"TAS Part I4 Food premises","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i4-food-premises#_01ae33c5-dab7-4e00-bb2d-830fc0f88101","x":"Delete clause I4O1 and insert TAS I4O1 as follows:\nThe objective of this Part is to facilitate the safe manufacture, preparation, storage and packing of food for sale for human consumption.","st":"TAS","base":"I4O1","g":"/ncc/tas-i4o1"},{"c":"TAS I4F1","t":"Food premises","p":"TAS Part I4 Food premises","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i4-food-premises#_879d5bc6-de18-40f6-8322-4c38c0935a67","x":"Delete clause I4F1 and insert TAS I4F1 as follows:\nEach building or part of a building constructed as a food premise must be able to be used in such a manner that minimises opportunities for food contamination.","st":"TAS","base":"I4F1","g":"/ncc/tas-i4f1"},{"c":"TAS I4P1","t":"Application of Part","p":"TAS Part I4 Food premises","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i4-food-premises#_01c49357-917f-4dc6-bd0c-638f5b648226","x":"Delete clause I4P1 and insert TAS I4P1 as follows:\n(1) TAS I4P2 to TAS I4P13 applies to any premises where food intended for human consumption is manufactured, processed, prepared, packed, stored or sold and to which the following apply—\nFood Act 2003; or\nLiquor Licensing Act 1990; or\nPrimary Produce Safety Act 2011; or\nDairy Industry Act 1994.\n(2) TAS I4P2 to TAS I4P13 includes, but is not limited to—\nbakehouses; and\nbar service areas; and\npremises for boning, curing, canning, pre-packing or other similar processes of preparation of meat for sale; and\nretail meat premises; and\neating houses and tea shops; and\nfish shops; and\nkitchens in eating houses, restaurants, guest houses, motels and hotels; and\nrooms for processing, manufacturing, packing, etc. of fruit and vegetables, dairy products, ice blocks, ices, meat-for-sale, or other fish; and\nprimary produce business premises regulated by or under a Food Safety Scheme made under the Primary Produce Safety Act; and\ntake-away-food stores; and\nbreweries and wineries.\n(3) In TAS I4P2 to TAS I4P13, words and meanings as defined in the Food Act 2003, Food Standards Code and Liquor Licensing Act 1990, Dairy Industry Act 1994 and Primary Produce Safety Act 2011 apply.\n(4) TAS I4P2 to TAS I4P13 do not apply to—\ndomestic dwellings classified as Class 1 buildings; or\nboarding houses or the like classified as Class 1 buildings; or\ntents, buildings or other structures used temporarily for serving meats to the public at any fair, show, race meeting or other public sports, games or amusements; or\nmeat premises covered by TAS Part I6; or\ndairies covered by TAS Part I7; or\nlive shellfish premises where live shellfish are being packed or handled for transport or transferral to shellfish processing premises; or\npremises that only sell pre-packaged food that is not potentially hazardous.","st":"TAS","base":"I4P1","g":"/ncc/tas-i4p1"},{"c":"TAS I4P2","t":"Design and construction","p":"TAS Part I4 Food premises","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i4-food-premises#_d964f906-e0d9-4623-a3cd-7f53950ccbcc","x":"Delete clause I4P2 and insert TAS I4P2 as follows:\nThe design and construction of food premises must—\nbe appropriate for the activities for which the premises are used; and\nprovide adequate space for the activities to be conducted on the food premises and for the fixtures, fittings and equipment used for those activities; and\npermit the food premises to be effectively cleaned and, if necessary, sanitised; and\nto the extent that is practicable—\nexclude dirt, dust, odours, fumes, smoke and other contaminants; and\nnot permit the entry of pests; and\nnot provide harbourage for pests; and\nprovide that the food premises is able to be used in such a manner that minimises opportunities for food contamination.","st":"TAS","base":"I4P2","g":"/ncc/tas-i4p2"},{"c":"TAS I4P3","t":"Water supply","p":"TAS Part I4 Food premises","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i4-food-premises#_d2a423d3-c166-425b-ac6e-8c5a55d367c5","x":"Delete clause I4P3 and insert TAS I4P3 as follows:\n(1) Food premises must have an adequate supply of water if water is to be used at the food premises for any of the activities conducted on the food premises.\n(2) A food premises must use potable water for all activities that use water that are conducted on the food premises.\nLimitations\nIf a food business demonstrates that the use of non-potable water for a purpose will not adversely affect the safety of the food handled by the food business TAS I4P3(2) does not apply.","st":"TAS","base":"I4P3","g":"/ncc/tas-i4p3"},{"c":"TAS I4P4","t":"Sewage and waste water disposal","p":"TAS Part I4 Food premises","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i4-food-premises#_7f7735ef-e6d0-41f7-a6bb-e26a9a9de447","x":"Delete clause I4P4 and insert TAS I4P4 as follows:\nFood premises must have a sewage and waste water disposal system that—\nwill effectively dispose of all sewage and waste water; and\nis constructed and located so that there is no likelihood of the sewage and waste water polluting the water supply or contaminating food.","st":"TAS","base":"I4P4","g":"/ncc/tas-i4p4"},{"c":"TAS I4P5","t":"Storage of garbage and recyclables","p":"TAS Part I4 Food premises","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i4-food-premises#_6b4ef2ad-9bdc-455b-bb91-7d0c88302717","x":"Delete clause I4P5 and insert TAS I4P5 as follows:\nFood premises must have facilities for the storage of garbage and recyclable matter that—\nadequately contain the volume and type of garbage and recyclable matter on the food premises; and\nenclose the garbage or recyclable matter, if this is necessary to keep pests and animals away from it; and\nare designed and constructed so that they may be effectively cleaned.","st":"TAS","base":"I4P5","g":"/ncc/tas-i4p5"},{"c":"TAS I4P6","t":"Ventilation","p":"TAS Part I4 Food premises","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i4-food-premises#_41d82e3c-6c95-4332-8c85-13d1b4c8ce31","x":"Delete clause I4P6 and insert TAS I4P6 as follows:\nFood premises must have sufficient natural or mechanical ventilation to remove fumes, smoke and vapours from the food premises.","st":"TAS","base":"I4P6","g":"/ncc/tas-i4p6"},{"c":"TAS I4P7","t":"Lighting","p":"TAS Part I4 Food premises","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i4-food-premises#_651c3900-81ea-4d75-be72-2532f67b1085","x":"Delete clause I4P7 and insert TAS I4P7 as follows:\nFood premises must have lighting systems that provide sufficient natural or artificial light for the activities conducted on the food premises.","st":"TAS","base":"I4P7","g":"/ncc/tas-i4p7"},{"c":"TAS I4P8","t":"Floors","p":"TAS Part I4 Food premises","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i4-food-premises#_105e17f7-1c03-441a-b239-584e33f58d2e","x":"Delete clause I4P8 and insert TAS I4P8 as follows:\n(1) Floors must be designed and constructed in a way that is appropriate for the activities conducted on the food premises.\n(2) Floors must—\nbe able to be effectively cleaned; and\nbe unable to absorb grease, food particles or water; and\nbe laid so that there is no ponding of water; and\nto the extent that is practicable, be unable to provide harbourage for pests.\nApplications\nThe requirements for floors apply to the floors of all areas used for food handling, cleaning, sanitising and personal hygiene except the following areas—\ndining areas; and\ndrinking areas; and\nother areas to which members of the public usually have access.\nExemptions\nThe following floors do not have to comply with TAS I4P8(2)—\nfloors of temporary food premises, including ground surfaces, that are unlikely to pose any risk of contamination of food handled on the food premises; and\nfloors of food premises that are unlikely to pose any risk of contamination of food handled on the food premises provided the food business has obtained approval for their use.","st":"TAS","base":"I4P8","g":"/ncc/tas-i4p8"},{"c":"TAS I4P9","t":"Walls and ceilings","p":"TAS Part I4 Food premises","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i4-food-premises#_b3121667-ff79-4442-b0a6-2be3b0f0dc86","x":"Delete clause I4P9 and insert TAS I4P9 as follows:\nWalls and ceilings—\nmust be designed and constructed in a way that is appropriate for the activities conducted on the food premises; and\nmust be provided where they are necessary to protect food from contamination; and\nprovided in accordance with (b) must be—\nsealed to prevent the entry of dirt, dust and pests; and\nunable to absorb grease, food particles or water; and\nable to be easily and effectively cleaned; and\nmust—\nbe able to be effectively cleaned; and\nto the extent that is practicable, be unable to provide harbourage for pests.\nApplications\nThe requirements for walls and ceilings apply to the walls and ceilings of all areas used for food handling, cleaning, sanitising and personal hygiene except for the following areas—\ndining areas; and\ndrinking areas; and\nother areas to which members of the public usually have access.","st":"TAS","base":"I4P9","g":"/ncc/tas-i4p9"},{"c":"TAS I4P10","t":"Hand washing facilities","p":"TAS Part I4 Food premises","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i4-food-premises#_a1abcdda-f041-42b7-b71e-cf891690800c","x":"Delete clause I4P10 and insert TAS I4P10 as follows:\n(1) Food premises must have hand washing facilities that are located where they can be easily accessed by food handlers—\nwithin areas where food handlers work if their hands are likely to be a source of contamination of food; and\nif there are toilets on the food premises — immediately adjacent to the toilets or toilet cubicles.\n(2) Hand washing facilities must be—\npermanent fixtures; and\nprovided with a supply of warm running potable water; and\nof a size that allows easy and effective hand washing; and\nclearly designated for the sole purpose of washing hands, arms and face.","st":"TAS","base":"I4P10","g":"/ncc/tas-i4p10"},{"c":"TAS I4P11","t":"Fixtures, fittings and equipment","p":"TAS Part I4 Food premises","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i4-food-premises#_9186babe-fa84-4f5a-b3f7-c6673c333c12","x":"Delete clause I4P11 and insert TAS I4P11 as follows:\nFixtures, fittings and equipment must—\nbe adequate for the production of wholesome food; and\nbe fit for their intended use; and\nbe designed, constructed, located and installed, and equipment must be located and, if necessary, installed, so that—\nthere is no likelihood that they will cause food contamination; and\nthey are able to be easily and effectively cleaned; and\nadjacent floors, walls, ceilings and other surfaces are able to be easily and effectively cleaned; and\nto the extent that is practicable, they do not provide harbourage for pests; and\nhave food contact surfaces—\nable to be easily and effectively cleaned and, if necessary, sanitised if there is a likelihood that they will cause food contamination; and\nunable to absorb grease, food particles and water if there is a likelihood that they will cause food contamination; and\nmade of a material that will not contaminate food.","st":"TAS","base":"I4P11","g":"/ncc/tas-i4p11"},{"c":"TAS I4P12","t":"Storage facilities","p":"TAS Part I4 Food premises","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i4-food-premises#_d103e10b-d401-40e7-b34d-95f376cde2ab","x":"Delete clause I4P12 and insert TAS I4P12 as follows:\nFood premises must have adequate storage facilities—\nfor the storage of items that are likely to be the source of contamination of food, including chemicals, clothing and personal belongings; and\nlocated where there is no likelihood of stored items contaminating food or food contact surfaces.","st":"TAS","base":"I4P12","g":"/ncc/tas-i4p12"},{"c":"TAS I4P13","t":"Refrigerated and cooling chambers","p":"TAS Part I4 Food premises","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i4-food-premises#_757ba051-8c39-403a-b751-145a702509e7","x":"Delete clause I4P13 and insert TAS I4P13 as follows:\nAll refrigerated and cooling chambers must be constructed so that the stored products will not be contaminated.","st":"TAS","base":"I4P13","g":"/ncc/tas-i4p13"},{"c":"TAS I4D1","t":"Application of Part","p":"TAS Part I4 Food premises","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i4-food-premises#_fff8e2d3-d02c-430d-8059-8b3ae7c5ae0d","x":"Delete clause I4D1 and insert TAS I4D1 as follows:\n(1) This Part applies to any premises where food intended for human consumption is manufactured, processed or sold and to which the following apply—\nFood Act 2003; or\nLiquor Licensing Act 1990; or\nPrimary Produce Safety Act 2011; or\nDairy Industry Act 1994.\n(2) This Part includes, but is not limited to—\nbakehouses; and\nbar service areas; and\npremises for boning, curing, canning, mincing, pre-packing or other similar processes of preparation of meat for sale; and\nretail meat premises; and\neating houses and tea shops; and\nfish shops; and\nkitchens in eating houses, restaurants, guest-houses, motels and hotels; and\nrooms for processing, manufacturing, packing, etc. of fruit and vegetables, dairy products, ice blocks, ices, meat-for-sale or other fish; and\nprimary produce business premises regulated by or under a Food Safety Scheme made under the Primary Produce Safety Act 2011; and\ntake-away-food stores; and\nbreweries and wineries.\n(3) This Part does not apply to—\nboarding houses or the like classified as Class 1 buildings; or\ntents, buildings or other structures used temporarily for serving meals to the public at any fair, show, race meeting or other public sports, games or amusements; or\ndairies covered by TAS Part I7; or\nlive shellfish premises where live shellfish are being packed or handled for transport or transferral to shellfish processing premises; or\npremises that only sell pre-packaged food that is not potentially hazardous.\n(4) In this Part, words and meanings as defined in the Food Act 2003, Food Standards Code and Liquor Licensing Act 1990, Dairy Industry Act 1994 and Primary Produce Safety Act 2011 apply.","st":"TAS","base":"I4D1","g":"/ncc/tas-i4d1"},{"c":"TAS I4D2","t":"Deemed-to-Satisfy Provisions","p":"TAS Part I4 Food premises","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i4-food-premises#_84ee9881-e709-4768-87df-da889f088778","x":"Delete clause I4D2 and insert TAS I4D2 as follows:\nPerformance Requirements TAS I4P1 to TAS I4P13 are satisfied by complying with the relevant provisions of TAS I4D3 to TAS I4D18.","st":"TAS","base":"I4D2","g":"/ncc/tas-i4d2"},{"c":"TAS I4D3","t":"General requirements","p":"TAS Part I4 Food premises","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i4-food-premises#_bdf9bfba-8b14-4fb6-9dc0-8ce668c13d3a","x":"Delete clause I4D3 and insert TAS I4D3 as follows:\n(1) The provision of—\nclose-fitting windows and doors; and\nair intakes that do not draw in contaminated air; and\nair locks and self-closing doors to separate toilet areas, laundries and living areas from food handling areas; and\nmechanical ventilation that removes sources of contamination,\nsatisfies TAS I4P2(d)(i).\n(2) The provision of—\nself-closing or pest-screened external doors; and\nmesh screens at opening windows or other ventilation openings; and\nsealing to drains, grease traps and ventilation pipes; and\nsealing to openings where pipes pass through external walls; and\nthe installation of pest-proof flashings to doors,\nsatisfies TAS I4P2(d)(ii).\n(3) The provision of—\nvermin-proof sealing; or\nfilling; or\naccess for inspection and cleaning of boxed-in areas,\nsatisfies TAS I4P2(d)(iii).\n(4) The provision of a reticulated water supply from—\na regulated entity; or\na private water supply with on-site treatment,\nwhich meets the Australian Drinking Water Guidelines, satisfies TAS I4P3(2).\nNotes\n‘Regulated entity’ has the same meaning as Water and Sewerage Industry Act 2008.","st":"TAS","base":"I4D3","g":"/ncc/tas-i4d3"},{"c":"TAS I4D4","t":"Pests and contaminants","p":"TAS Part I4 Food premises","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i4-food-premises#_8e86f750-4c12-40eb-aa88-d6bab0a4fd45","x":"Delete clause I4D4 and insert TAS I4D4 as follows:\nPremises where customers are served outside the premises through an opening, that has an appliance for the elimination of flies and mechanical ventilation adequate to exhaust air through the opening at a rate of not less than 5 litres per second for each square metre of opening, satisfies TAS I4P2(d).","st":"TAS","base":"I4D4","g":"/ncc/tas-i4d4"},{"c":"TAS I4D5","t":"Drains and pipes","p":"TAS Part I4 Food premises","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i4-food-premises#_cfa7a9d9-c213-491e-a083-5a43d72ea231","x":"Delete clause I4D5 and insert TAS I4D5 as follows:\nPremises satisfy TAS I4P4 where—\na grease trap, an overflow (relief) gully or an untrapped opening connected directly with a drain or sewer, is not installed in a room used for preparation, processing, packing or storing of food for sale; and\nas far as is practicable, service pipes are concealed beneath the surface of walls, floors or ceilings, or are fixed clear of the wall, floor or ceiling, at such distance as to facilitate cleaning.","st":"TAS","base":"I4D5","g":"/ncc/tas-i4d5"},{"c":"TAS I4D6","t":"Offensive material and trade waste","p":"TAS Part I4 Food premises","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i4-food-premises#_eea5695b-50c0-4621-9efa-09af0019850d","x":"Delete clause I4D6 and insert TAS I4D6 as follows:\nWhere offensive material or trade waste is stored, a separate area or room which—\nis paved and easily cleanable; and\nis graded to drain to a suitable drainage system; and\nhas available a supply of water under pressure,\nsatisfies TAS I4P5.","st":"TAS","base":"I4D6","g":"/ncc/tas-i4d6"},{"c":"TAS I4D7","t":"Ventilation","p":"TAS Part I4 Food premises","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i4-food-premises#_1903f69e-25f0-4ec2-8f49-655f7fca4b24","x":"Delete clause I4D7 and insert TAS I4D7 as follows:\nA mechanical ventilating exhaust system complying with the requirements of AS/NZS 1668.1 and AS 1668.2 satisfies TAS I4P6.","st":"TAS","base":"I4D7","g":"/ncc/tas-i4d7"},{"c":"TAS I4D8","t":"Lighting","p":"TAS Part I4 Food premises","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i4-food-premises#_e2a823b4-750a-451e-b12b-72dfe013f8a2","x":"Delete clause I4D8 and insert TAS I4D8 as follows:\nA lighting system that—\ncomplies with AS 1680.1 and AS/NZS 1680.2.4; and\nin areas where open food is handled or stored, has light fittings which are—\ndesigned and constructed to prevent the contamination of food should the globe or tube shatter; and\nfree from any features that would harbour dirt, dust or insects or make the fitting difficult to clean,\nsatisfies TAS I4P7.","st":"TAS","base":"I4D8","g":"/ncc/tas-i4d8"},{"c":"TAS I4D9","t":"Floors, walls and ceilings","p":"TAS Part I4 Food premises","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i4-food-premises#_b911f434-8f09-4898-93a6-1a0af88098ef","x":"Delete clause I4D9 and insert TAS I4D9 as follows:\n(1) Floors, walls and ceilings constructed in accordance with Section 3 of AS 4674, satisfy TAS I4P8 and TAS I4P9.\n(2) The wall and ceiling provisions of (1) do not apply to areas in which all food for sale is completely enclosed and otherwise protected from contamination by processing plants, other appliances or other means.","st":"TAS","base":"I4D9","g":"/ncc/tas-i4d9"},{"c":"TAS I4D10","t":"Separation of work place","p":"TAS Part I4 Food premises","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i4-food-premises#_7a85664d-b191-4ebc-990b-95ab99fd8538","x":"Delete clause I4D10 and insert TAS I4D10 as follows:\n(1) A room where food for sale is processed, manufactured, prepared, deposited, treated, stored or packed, that does not have direct communication with a room containing sanitary facilities, living quarters, laundry, bathroom or garage or a room where animals are housed, satisfies TAS I4P9(b).\n(2) ‘Direct communication’ means a doorway, a window or other opening in a wall between a food preparation or storage area opening directly on to a room described in (1).\n(3) Access between the areas referred to in (2) via another room, a hallway, or an airlock, satisfies TAS I4P9(b).","st":"TAS","base":"I4D10","g":"/ncc/tas-i4d10"},{"c":"TAS I4D11","t":"Washbasins","p":"TAS Part I4 Food premises","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i4-food-premises#_703692b5-e681-4500-9201-6d3e0c562bd3","x":"Delete clause I4D11 and insert TAS I4D11 as follows:\n(1) Premises or places for preparation or storage of food for sale provided with not less than one washbasin complying with (2) within five metres of any activities where hands are likely to be a source of contamination of food, satisfies TAS I4P10.\n(2) Each washbasin must—\nhave hot and cold water through a common outlet; and\nhave a capacity of at least 11 litres; and\nprovide not less than 250 mm between the spout and the bottom of the basin; and\nbe in a position that is not obstructed.","st":"TAS","base":"I4D11","g":"/ncc/tas-i4d11"},{"c":"TAS I4D12","t":"Sinks","p":"TAS Part I4 Food premises","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i4-food-premises#_32245523-cf27-412d-802c-d0943f851964","x":"Delete clause I4D12 and insert TAS I4D12 as follows:\n(1) Where equipment and utensils are required to be manually cleaned and sanitised, or food preparation requires a sink, premises that are provided with a suitably sized double bowl sink for equipment washing and a separate suitably sized sink for food preparation of stainless steel supplied with—\nhot and cold water; and\nin integral drainer on at least one side or a third bowl,\nsatisfies TAS I4P11.\n(2) A sink installed adjacent to a wall or other vertical surface, that is fitted with an integral flashing to that wall or vertical surface to a height of not less than 150 mm, satisfies TAS I4P11.\n(3) A sink provided with an integral surround not less than 150 mm wide except on sides with an integral flashing as in (2), satisfies TAS I4P11.\n(4) A cleaner’s sink separated from food storage and handling areas provided for the emptying of cleaning water, satisfies TAS I4P11.","st":"TAS","base":"I4D12","g":"/ncc/tas-i4d12"},{"c":"TAS I4D13","t":"Design, construction and installation of fixtures, fittings and equipment","p":"TAS Part I4 Food premises","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i4-food-premises#_cb7eb75e-7413-49ba-81a9-b7b532bef9e9","x":"Delete clause I4D13 and insert TAS I4D13 as follows:\n(1) The provision of fixtures, fittings and equipment designed, constructed and installed in accordance with clause 4.2 and clause 4.3 of AS 4674 satisfies TAS I4P11.\n(2) The provision of—\nautomatic equipment that uses water to sanitise utensils or other equipment and only operate for the purposes of sanitation when the water is at a temperature that will sanitise the utensils or equipment; or\na sink that meets TAS I4D12,\nsatisfies TAS I4P11.","st":"TAS","base":"I4D13","g":"/ncc/tas-i4d13"},{"c":"TAS I4D14","t":"Storage of materials and equipment","p":"TAS Part I4 Food premises","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i4-food-premises#_153715d7-b4fa-4ec6-a7dd-fee4c5afa189","x":"Delete clause I4D14 and insert TAS I4D14 as follows:\n(1) Separate areas for the storage of fuel, cleaning compounds and general maintenance equipment provided so as to prevent contamination of the product in the event of a spillage of any other form of breakdown, satisfies TAS I4P12.\n(2) A separate area for the storage of staff clothing and personal effects, satisfies TAS I4P12.","st":"TAS","base":"I4D14","g":"/ncc/tas-i4d14"},{"c":"TAS I4D15","t":"Food store","p":"TAS Part I4 Food premises","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i4-food-premises#_ea750d01-76a6-4456-8b50-a55e57aff440","x":"Delete clause I4D15 and insert TAS I4D15 as follows:\nAn eating house provided with a dry-food store, satisfies TAS I4P12.","st":"TAS","base":"I4D15","g":"/ncc/tas-i4d15"},{"c":"TAS I4D16","t":"Meat premises","p":"TAS Part I4 Food premises","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i4-food-premises#_a1028819-1ab3-46d8-8acf-ee3d6ef27215","x":"Delete clause I4D16 and insert TAS I4D16 as follows:\nPremises used for the preparation or sale of red meat, other than those licensed under the Primary Produce Safety Act 2011, that comply with—\nTAS Part I6; or\nthe provisions of TAS I4D3 to TAS I4D14 and I4D18, satisfy in relation to building construction, the requirements of TAS I4P2 to TAS I4P13.","st":"TAS","base":"I4D16","g":"/ncc/tas-i4d16"},{"c":"TAS I4D17","t":"Dairy produce","p":"TAS Part I4 Food premises","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i4-food-premises#_ca4a59a2-0b24-40a2-92f0-b05251fd42be","x":"Delete clause I4D17 and insert TAS I4D17 as follows:\nDefinition:\nDairy produce products include milk, colostrum, liquid milk products, cream and thickened cream, butter, butter concentrate, buttermilk, concentrated buttermilk, dairy blend, ghee, anhydrous milk fat (butter oil), casein, caseinate, cheese, whey, whey cream, concentrated whey cream, cultured milk, yoghurt, ice cream, ice cream mix, buttermilk powder, lactose powder, milk sugar, powdered milk, skim milk powder, whey powder, milk protein powder and other milk concentrates.\nPremises designed and constructed in compliance with the Export Control (Milk and Dairy) Orders, satisfy the special requirements of this code for premises to be used for the manufacture of dairy produce.","st":"TAS","base":"I4D17","g":"/ncc/tas-i4d17"},{"c":"TAS I4D18","t":"Refrigerated and cooling chambers","p":"TAS Part I4 Food premises","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i4-food-premises#_53f77669-5748-4951-8fb5-d537eefec84a","x":"Delete clause I4D18 and insert TAS I4D18 as follows:\nThe construction of a refrigerated chamber or cooling chamber installed in premises for storage of food complying with the requirements for that premises, satisfies TAS I4P13 where they have—\ninternal and external panels adhered directly to the insulated core material to form an integral wall section with tight fitting edges resistant to penetration by liquids; and\nevery joint caulked with a water-resistant, flexible sealer and finished in such a manner as to prevent migration of liquids into the core; and\nevery intersection of walls with floors and walls with walls coved with a radius not less than 25 mm; and\nexposed slot-head screws or open-headed pop rivets filled with sealer; and\nservice pipes and conduits concealed in floors, walls or ceilings, if practicable, or fixed on brackets to provide clearances of not less than 25 mm between the pipe and a wall and 100 mm between the pipe and a floor; and\nfittings not fixed over exposed pipes nor in a position to make difficult the cleaning of the pipe and surrounding area; and\nrat proof construction, and any inaccessible spaces between the low temperature room and surrounding walls, ceilings and fixtures proof against rats an vermin; and\nfloor graded, as shown in Table TAS I4D18a, to drains located outside the chamber as near as practicable to the door opening; and\ndrainage from cooling units within the chamber constructed in accordance with Table TAS I4D18b, draining to a trapped outlet located outside the chamber.\nInsert TAS table (I4D18a) I4D18 as follows:\nTAS Table I4D18a: Floor drainage of refrigerated cooling chambers\nChiller type\nFloor slope\nActive chillers\nNot less than 1:50\nOther chambers\nNot less than 1:100\nInsert TAS table (I4D18b) I4D18 as follows:\nTAS Table I4D18b: Drainage from cooling units within refrigerated chambers or cooling chambers\nCooling unit type\nDrainage requirements\nWall-mounted\nDrain water must be contained and removed by either a wall-mounted channel or a spoon drain located under the coil.\nFloor-mounted\nDrain water must be confined by kerbs, of a height not less than 150 mm, and directed to a trapped drain outlet.\nCeiling-mounted\nDrain water must be confined by suitable insulated drip trays directly connected to the drainage system.","st":"TAS","base":"I4D18","g":"/ncc/tas-i4d18"},{"c":"TAS I5D1","t":"Application of Part","p":"TAS Part I5 Dining rooms and bar rooms","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i5-dining-rooms-and-bar-rooms#_0d70dcee-1643-4795-a40d-7623690b757a","x":"Delete clause I5D1 and insert TAS I5D1 as follows:\n(1) This Part applies to all dining rooms and bar rooms (excluding bar service areas) on licensed premises covered by the Liquor Licensing Act 1990.\n(2) Dining rooms and bar rooms must provide for the comfort, convenience and health of customers.","st":"TAS","base":"I5D1","g":"/ncc/tas-i5d1"},{"c":"TAS I5D2","t":"Sanitary facilities","p":"TAS Part I5 Dining rooms and bar rooms","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i5-dining-rooms-and-bar-rooms#_075e5605-ffa1-4648-b824-0de62f5b2a2c","x":"Delete clause I5D2 and insert TAS I5D2 as follows:\n(1) Separate sanitary facilities for male sand females must be provided in close proximity to each dining room and bar room in licensed premises.\n(2) Where the sanitary facilities are not accessed from within the dining room or bar room, reasonable fixed protection from the elements must be provided.","st":"TAS","base":"I5D2","g":"/ncc/tas-i5d2"},{"c":"TAS I5D3","t":"Separation from other areas","p":"TAS Part I5 Dining rooms and bar rooms","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i5-dining-rooms-and-bar-rooms#_4d2c11c1-ff4c-40f7-9c00-76f079a3c0b9","x":"Delete clause I5D3 and insert TAS I5D3 as follows:\nA dining room must not have a direct opening to living quarters, a laundry, bathroom or garage or a room where animals are housed.","st":"TAS","base":"I5D3","g":"/ncc/tas-i5d3"},{"c":"TAS I6D1","t":"Application of Part","p":"TAS Part I6 Meat premises","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i6-meat-premises#_3b4aa97e-836b-4aea-9aaf-3b498ccb44c9","x":"Delete clause I6D1 and insert TAS I6D1 as follows:\n(1) This Part is applicable to—\nmeat premises processing animals, including game and poultry, and producing meat and meat products for human consumption; and\npet food works licensed under the Primary Produce Safety Act 2011.\n(2) Meat premises must be constructed in such a manner that—\ndoes not jeopardise animal welfare; and\nprovides for hygienic processing of animals; and\nensures the wholesomeness of meat and meat products.","st":"TAS","base":"I6D1","g":"/ncc/tas-i6d1"},{"c":"TAS I6D2","t":"Premises processing animals and meat","p":"TAS Part I6 Meat premises","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i6-meat-premises#_b3633799-cc0a-4551-a9ad-03b3a948205d","x":"Delete clause I6D2 and insert TAS I6D2 as follows:\nPremises used for the processing of animals and meat for human consumption must comply with the relevant Parts and Sections of the Australian Standards listed below:\nHygienic Production and Transportation of Meat and Meat Products for Human Consumption, AS 4696 - Part 7, Sections 19 to 21.\nHygienic Production of Game Meat for Human Consumption, AS 4464 - Section 6.\nConstruction of Premises and Hygienic Production of Poultry Meat for Human Consumption, AS 4465 - Part A, Sections 3 to 12.\nHygienic Production of Rabbit Meat for Human Consumption, AS 4466 - Section 5.\nHygienic Rendering of Animal Products, AS 5008 - Section 3.\nHygienic Production of Ratite (Emu/Ostrich) Meat for Human Consumption, AS 5010 - Section 5.\nHygienic Production of Natural Casings for Human Consumption, AS 5011 - Section 4.\nHygienic Production of Pet Meat, PISC - Technical Report 88 - Sections, 6.1 to 6.7, 6.9 and 6.11.","st":"TAS","base":"I6D2","g":"/ncc/tas-i6d2"},{"c":"TAS I7D1","t":"Application of Part","p":"TAS Part I7 Farm dairy premises","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i7-farm-dairy-premises#_39f16da3-2c1d-424d-92ce-a4786bd873de","x":"Delete clause I7D1 and insert TAS I7D1 as follows:\n(1) This Part is applicable to every farm dairy as covered by the Dairy Industry Act 1994.\n(2) Dairies must be constructed in such a manner that contamination of milk can be avoided.","st":"TAS","base":"I7D1","g":"/ncc/tas-i7d1"},{"c":"TAS I7D2","t":"Milking sheds and holding yards","p":"TAS Part I7 Farm dairy premises","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i7-farm-dairy-premises#_17bf0a78-8923-45d9-aede-dfb175a331af","x":"Delete clause I7D2 and insert TAS I7D2 as follows:\n(1) The walls (including the walls of a pit of a herringbone design milking shed) must be non-absorbent and easy to clean.\n(2) The floor of a holding yard and a milking shed must be non-absorbent, easy to clean and free-draining.\n(3) The lighting of a holding yard and a milking shed must be adequate for proper milking.\n(4) The working space in a milking shed is to be sufficient to minimise the risk of contamination of milk during milking.\n(5) Effluent from a holding yard and a milking shed is to be drained to a suitable point for disposal.\n(6) The requirements of (1), (2) and (3) are satisfied if—\nthe walls are constructed of well-compacted smooth finish concrete or other material sealed to be impervious to moisture; and\nthe floors are constructed of well-compacted smooth finish concrete and are graded to a drain; and\njoints between wall sections and walls and walls and floors are sealed to prevent entry of water and pests; and\nartificial lighting is designed to comply with AS 1680.","st":"TAS","base":"I7D2","g":"/ncc/tas-i7d2"},{"c":"TAS I7D3","t":"Milk receiving area and milk storage room","p":"TAS Part I7 Farm dairy premises","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i7-farm-dairy-premises#_48a4a199-41fb-4694-ba1d-2d808a4e0709","x":"Delete clause I7D3 and insert TAS I7D3 as follows:\n(1) A Milk Receiving Area and Milk Storage Room must—\nhave internal surfaces that are smooth, non-absorbent, free-draining and easy to clean; and\nbe constructed so as to prevent the entry of dust, insects, pests, birds and animals; and\nhave adequate artificial lighting that—\nis located to provide a clear view of the milk for grading and measuring purposes; and\nthe lights over a bulk vat are to be protected to prevent glass entering the vat if the light is broken; and\nhave switches appropriately located in milk collection areas; and\nhave adequate ventilation to aid the drying of floors and walls between milkings.\n(2) The requirements of (1) are satisfied if—\nthe floors are constructed of well-compacted, smooth finish concrete and graded to a drain; and\nthe internal surfaces are smooth, sealed and washable; and\njoists between wall sections and walls and floors are sealed to prevent entry of water and pests; and\nartificial lighting is designed to comply with AS 1680; and\nall openings are fitted with doors, windows or screens; and\nventilation is provided in accordance with F6D6.","st":"TAS","base":"I7D3","g":"/ncc/tas-i7d3"},{"c":"TAS I7D4","t":"Water supply","p":"TAS Part I7 Farm dairy premises","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i7-farm-dairy-premises#_f1ef3b28-dcdd-4cac-a6d7-63ce5797748d","x":"Delete clause I7D4 and insert TAS I7D4 as follows:\nAn adequate and suitable supply of water must be available for plant sanitation, teat washing, milk cooling and vat rinsing.","st":"TAS","base":"I7D4","g":"/ncc/tas-i7d4"},{"c":"TAS I8D1","t":"Application of Part","p":"TAS Part I8 Pharmacies","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i8-pharmacies#_db213f56-c3a4-410a-892c-5eccd2d0a051","x":"Delete clause I8D1 and insert TAS I8D1 as follows:\n(1) This Part applies to all pharmacy business premises registered under the Pharmacy Control Act.\n(2) Pharmacies must be able to be secured against entry and the interior must be able to be supervised by a pharmacist.","st":"TAS","base":"I8D1","g":"/ncc/tas-i8d1"},{"c":"TAS I8D2","t":"Definition","p":"TAS Part I8 Pharmacies","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i8-pharmacies#_066af0a8-6ce5-4ee6-b0e3-4cc31fa52bc0","x":"Delete clause I8D2 and insert TAS I8D2 as follows:\nIn this Part the term “dispensary” means the room or area within a pharmacy or other premises which a registered pharmaceutical chemist uses for the compounding or dispensing of prescriptions, medicines or drugs.","st":"TAS","base":"I8D2","g":"/ncc/tas-i8d2"},{"c":"TAS I8D3","t":"Pharmacy premises","p":"TAS Part I8 Pharmacies","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i8-pharmacies#_62789290-feef-408a-9a05-b97d489f4b74","x":"Delete clause I8D3 and insert TAS I8D3 as follows:\n(1) Each premises used as a pharmacy must have—\na dispensary for the compounding or dispensing of drugs and for the storage of material used in dispensing; and\nspace for the storage of narcotic substances and poisons as required by the Poisons Regulations; and\na place for unpacking of containers or cases and goods; and\na room for storing merchandise not used in dispensing.\n(2) A pharmacy may have one area set aside for retailing merchandise that is not compounded or dispensed.","st":"TAS","base":"I8D3","g":"/ncc/tas-i8d3"},{"c":"TAS I8D4","t":"Dispensary","p":"TAS Part I8 Pharmacies","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i8-pharmacies#_e7dfce1a-a5c0-4d64-9c72-9a619a86d81e","x":"Delete clause I8D4 and insert TAS I8D4 as follows:\n(1) A dispensary must be located—\nwithin a pharmacy in a position to enable a person in the dispensary to supervise the dispensary, storage areas for narcotic substances and poisons, the entrances to unpacking areas and areas for storing other substances, and the retail area; and\nseparate from any place where goods are unpacked or where general merchandise, not used in dispensing, is stored.\n(2) Each dispensary must be provided with—\na sink and drainage board of impervious material moulded or manufactured in one piece; and\na reticulated supply of hot and cold water capable of providing to the sink adequate quantities of water for dispensing purposes; and\nspace for a dispensing bench with a working area not less than 1.4 m2.","st":"TAS","base":"I8D4","g":"/ncc/tas-i8d4"},{"c":"TAS I8D5","t":"Security of dispensary","p":"TAS Part I8 Pharmacies","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i8-pharmacies#_e9e5a560-d5bb-4246-9e80-c49d2ca2c49e","x":"Delete clause I8D5 and insert TAS I8D5 as follows:\n(1) Every dispensary and enclosure set aside for the storage of narcotic substances and poisons must be able to be secured against entry.\n(2) If a dispensary is located in a pharmacy that is capable of being secured against entry at all times while the dispensary is not in use, then the dispensary is deemed to be secured against entry.","st":"TAS","base":"I8D5","g":"/ncc/tas-i8d5"},{"c":"TAS I9D1","t":"Application of Part","p":"TAS Part I9 Health service establishments","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i9-health-service-establishments#_8d07ec48-6900-4233-ad02-817367cf109c","x":"Delete clause I9D1 and insert TAS I9D1 as follows:\n(1) This Part applies to health service establishments as defined in the Health Service Establishment Act 2006 including—\na day procedure centre; or\na private hospital; or\na residential care service building.\n(2) Health service establishments must be able to be easily cleaned and must have adequate space for patients.","st":"TAS","base":"I9D1","g":"/ncc/tas-i9d1"},{"c":"TAS I9D2","t":"Design and construction of health service establishments","p":"TAS Part I9 Health service establishments","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-i9-health-service-establishments#_b08998b5-75ab-4f90-b024-d6a4b98badab","x":"Delete clause I9D2 and insert TAS I9D2 as follows:\nEvery health service establishment must be constructed and maintained in accordance with the Australasian Health Facility Guidelines.","st":"TAS","base":"I9D2","g":"/ncc/tas-i9d2"},{"c":"TAS Part J3","t":"Elemental provisions for a Class 4 part of a building","p":"TAS Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/9-tasmania/tas-j3-elemental-provisions-class-4-part-building","x":"This Part has deliberately been left blank. This Part is deleted from the BCA in Tasmania. In Tasmania, for a Class 2 building and Class 4 part of a building, Section J is replaced with Section J of BCA 2019 Amendment 1.","st":"TAS","base":"Part J3","g":"/ncc/tas-part-j3"},{"c":"S1C1","t":"Scope","p":"Specification 1 Fire-resistance of building elements","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/1-fire-resistance-building-elements#S1C1","x":"This Specification sets out the procedures for determining the FRL of building elements.","g":"/ncc/s1c1","a19":["Sch. 5: 1"]},{"c":"Table S1C2a","t":"FRLs deemed to be achieved by walls — masonry","p":"Specification 1 Fire-resistance of building elements","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/1-fire-resistance-building-elements#_daccc233-53a6-43bf-bb27-6cdd3f8d356a","x":"Masonry type | Minimum thickness (mm) of principal material for FRLs\n60/60/60 | 90/90/90 | 120/120/120 | 180/180/180 | 240/240/240\nAshlar | - | - | - | - | 300\nCalcium silicate | See clause S1C2(d)(iv)\nConcrete\nFired clay\nTable Notes\nFor the purposes of this table, each element must meet the requirements of Specification 2.","tb":"S1C2","g":"/ncc/table-s1c2a"},{"c":"Table S1C2b","t":"FRLs deemed to be achieved by walls — concrete","p":"Specification 1 Fire-resistance of building elements","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/1-fire-resistance-building-elements#_2c7a54f6-6890-4add-8212-3fc3ca3bb9d2","x":"Concrete type | Minimum thickness (mm) of principal material for FRLs\n60/60/60 | 90/90/90 | 120/120/120 | 180/180/180 | 240/240/240\nNo fines | - | - | - | 150 | 300\nPrestressed | See clause S1C2(d)(iv)\nReinforced\nPlain | - | - | - | 150 | 170\nTable Notes\nFor the purposes of this table, each element must meet the requirements of Specification 2.","tb":"S1C2","g":"/ncc/table-s1c2b"},{"c":"Table S1C2c","t":"FRLs deemed to be achieved by walls — gypsum","p":"Specification 1 Fire-resistance of building elements","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/1-fire-resistance-building-elements#_e00aed9f-60e4-4fca-92c0-39f45a21b525","x":"Gypsum type | Minimum thickness (mm) of principal material for FRLs\n60/60/60 | 90/90/90 | 120/120/120 | 180/180/180 | 240/240/240\nSolid gypsum blocks | 75 | 90 | 100 | 110 | 125\nGypsum — perlite or gypsum vermiculite-plaster on metal lath and channel (non-load bearing walls only) | 50 | 50 | 65 | - | -\nTable Notes\nFor the purposes of this table, each element must meet the requirements of Specification 2.","tb":"S1C2","g":"/ncc/table-s1c2c"},{"c":"Table S1C2d","t":"FRLs deemed to be achieved by concrete columns","p":"Specification 1 Fire-resistance of building elements","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/1-fire-resistance-building-elements#_aded96c9-0efa-499a-9ca2-96868546dabc","x":"Column type | Minimum thickness (mm) of principal material for FRLs\n60/60/60 | 90/90/90 | 120/120/120 | 180/180/180 | 240/240/240\nPrestressed | See clause S1C2(d)(ii)\nReinforced","tb":"S1C2","g":"/ncc/table-s1c2d"},{"c":"Table S1C2e","t":"FRLs deemed to be achieved by hot-rolled steel columns (including a fabricated column) exposed on not more than 3 sides","p":"Specification 1 Fire-resistance of building elements","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/1-fire-resistance-building-elements#_86a6bb55-fabb-4a09-ba2e-a88ed4b7262c","x":"Fire protection | Minimum thickness (mm) of principal material for FRLs\n60/60/60 | 90/90/90 | 120/120/120 | 180/180/180 | 240/240/240\nConcrete cast in-situ — load bearing | 25 | 30 | 40 | 55 | 75\nConcrete cast in-situ — non-load bearing unplastered | 25 | 30 | 40 | 50 | 75\nConcrete cast in-situ — non-load bearing plastered 13 mm | 25 | 25 | 30 | 40 | 50\nGypsum cast in-situ | - | - | - | - | 50\nGypsum — perlite or gypsum-vermiculite plaster—sprayed to contour | 20 | 25 | 35 | 50 | 55\nGypsum — perlite or gypsum-vermiculite plaster—sprayed on metal lath | 20 | 20 | 25 | 35 | 45\nTable Notes\nFor the purposes of this table, each element must meet the requirements of Specification 2.","tb":"S1C2","g":"/ncc/table-s1c2e"},{"c":"Table S1C2f","t":"FRLs deemed to be achieved by hot-rolled steel columns (including a fabricated column) exposed on no more than 3 sides and with column spaces filled","p":"Specification 1 Fire-resistance of building elements","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/1-fire-resistance-building-elements#_a1c29a52-ba49-40ba-a135-f5c91d7cf6c5","x":"Fire protection | Minimum thickness (mm) of principal material for FRLs\n60/60/60 | 90/90/90 | 120/120/120 | 180/180/180 | 240/240/240\nSolid calcium-silicate masonry | 50 | 50 | 50 | 50 | 65\nSolid clay masonry | 50 | 50 | 50 | 65 | 90\nSolid concrete masonry | 50 | 50 | 50 | 65 | 90\nSolid gypsum blocks | 50 | 50 | 50 | 50 | 65\nHollow terracotta blocks — plastered 13 mm | 50 | 50 | 50 | 65 | 90\nTable Notes\nFor the purposes of this table, each element must meet the requirements of Specification 2.","tb":"S1C2","g":"/ncc/table-s1c2f"},{"c":"Table S1C2g","t":"FRLs deemed to be achieved by hot-rolled steel columns (including a fabricated column) exposed on no more than 3 sides and with column spaces unfilled","p":"Specification 1 Fire-resistance of building elements","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/1-fire-resistance-building-elements#_c7d3b3a8-1538-44ec-a7a5-5e971e6aa915","x":"Fire protection | Minimum thickness (mm) of principal material for FRLs\n60/60/60 | 90/90/90 | 120/120/120 | 180/180/180 | 240/240/240\nSolid calcium-silicate masonry | 50 | 50 | 50 | - | -\nSolid clay masonry | 50 | 50 | 65 | - | -\nSolid concrete masonry | 50 | 50 | 65 | - | -\nSolid gypsum blocks | 50 | 50 | 50 | - | -\nHollow terracotta blocks — plastered 13 mm | 50 | 50 | 65 | - | -\nTable Notes\nFor the purposes of this table, each element must meet the requirements of Specification 2.","tb":"S1C2","g":"/ncc/table-s1c2g"},{"c":"Table S1C2h","t":"FRLs deemed to be achieved by hot-rolled steel columns (including a fabricated column) exposed on no more than 4 sides","p":"Specification 1 Fire-resistance of building elements","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/1-fire-resistance-building-elements#_9a6e9c0d-671b-4a75-8c84-4f88cae52690","x":"Fire protection | Minimum thickness (mm) of principal material for FRLs\n60/–/– | 90/–/– | 120/–/– | 180/–/– | 240/–/–\nConcrete cast in-situ — load bearing | 25 | 40 | 45 | 65 | 90\nConcrete cast in-situ — non-load bearing unplastered | 25 | 30 | 40 | 50 | 65\nConcrete cast in-situ — non-load bearing plastered 13 mm | 25 | 25 | 30 | 40 | 50\nGypsum cast in-situ | - | - | - | - | 50\nGypsum — perlite or gypsum-vermiculite plaster — sprayed to contour | 25 | 30 | 40 | 55 | 65\nGypsum — perlite or gypsum-vermiculite plaster — sprayed on metal lath | 20 | 20 | 30 | 40 | 50\nTable Notes\nFor the purposes of this table, each element must meet the requirements of Specification 2.","tb":"S1C2","g":"/ncc/table-s1c2h"},{"c":"Table S1C2i","t":"FRLs deemed to be achieved by hot-rolled steel columns (including a fabricated column) exposed on no more than 4 sides and with column spaces filled","p":"Specification 1 Fire-resistance of building elements","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/1-fire-resistance-building-elements#_19ba2059-317d-4c69-88cd-746b98037e83","x":"Fire protection | Minimum thickness (mm) of principal material for FRLs\n60/–/– | 90/–/– | 120/–/– | 180/–/– | 240/–/–\nSolid calcium-silicate masonry | 50 | 50 | 50 | 65 | 75\nSolid clay masonry | 50 | 50 | 50 | 75 | 100\nSolid concrete masonry | 50 | 50 | 50 | 75 | 100\nSolid gypsum blocks | 50 | 50 | 50 | 65 | 75\nHollow terracotta blocks — plastered 13 mm | 50 | 50 | 50 | 75 | 100\nTable Notes\nFor the purposes of this table, each element must meet the requirements of Specification 2.","tb":"S1C2","g":"/ncc/table-s1c2i"},{"c":"Table S1C2j","t":"FRLs deemed to be achieved by hot-rolled steel columns (including a fabricated column) exposed on no more than 4 sides and with column spaces unfilled","p":"Specification 1 Fire-resistance of building elements","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/1-fire-resistance-building-elements#_550c8399-b9b7-411a-b5dd-6a1a07939fc7","x":"Fire protection | Minimum thickness (mm) of principal material for FRLs\n60/–/– | 90/–/– | 120/–/– | 180/–/– | 240/–/–\nSolid calcium-silicate masonry | 50 | 50 | 50 | - | -\nSolid clay masonry | 50 | 50 | 65 | - | -\nSolid concrete masonry | 50 | 50 | 65 | - | -\nSolid gypsum blocks | 50 | 50 | 50 | - | -\nHollow terracotta blocks — plastered 13 mm | 50 | 50 | 65 | - | -\nTable Notes\nFor the purposes of this table, each element must meet the requirements of Specification 2.","tb":"S1C2","g":"/ncc/table-s1c2j"},{"c":"Table S1C2k","t":"FRLs deemed to be achieved by concrete beams","p":"Specification 1 Fire-resistance of building elements","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/1-fire-resistance-building-elements#_9854dac4-51b2-4b31-b76a-f7101747e649","x":"Concrete type | Minimum thickness (mm) of principal material for FRLs\n60/–/– | 90/–/– | 120/–/– | 180/–/– | 240/–/–\nPrestressed | See clause S1C2(d)(ii)\nReinforced","tb":"S1C2","g":"/ncc/table-s1c2k"},{"c":"Table S1C2l","t":"FRLs deemed to be achieved by hot-rolled steel beams (including an open-web joist, girder, truss, etc.) exposed on no more than 3 sides","p":"Specification 1 Fire-resistance of building elements","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/1-fire-resistance-building-elements#_72be61a5-0a55-4742-900f-78919245c3f0","x":"Fire protection | Minimum thickness (mm) of principal material for FRLs\n60/–/– | 90/–/– | 120/–/– | 180/–/– | 240/–/–\nConcrete — cast in-situ | 25 | 30 | 40 | 50 | 65\nGypsum — perlite or gypsum-vermiculite plaster — sprayed to contour | 20 | 25 | 35 | 50 | 55\nGypsum — perlite or gypsum-vermiculite plaster — sprayed on metal lath | 20 | 20 | 25 | 35 | 45\nTable Notes\nFor the purposes of this table, each element must meet the requirements of Specification 2.","tb":"S1C2","g":"/ncc/table-s1c2l"},{"c":"Table S1C2m","t":"FRLs deemed to be achieved by hot-rolled steel beams (including an open-web joist, girder, truss, etc.) exposed on 4 sides","p":"Specification 1 Fire-resistance of building elements","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/1-fire-resistance-building-elements#_f2d7be78-d3e1-4ac4-85f7-73c814dad364","x":"Fire protection | Minimum thickness (mm) of principal material for FRLs\n60/–/– | 90/–/– | 120/–/– | 180/–/– | 240/–/–\nConcrete — cast in-situ | 25 | 40 | 45 | 60 | 90\nGypsum — perlite or gypsum-vermiculite plaster — sprayed to contour | 20 | 30 | 40 | 55 | 65\nGypsum — perlite or gypsum-vermiculite plaster — sprayed on metal lath | 20 | 20 | 35 | 40 | 50\nTable Notes\nFor the purposes of this table, each element must meet the requirements of Specification 2.","tb":"S1C2","g":"/ncc/table-s1c2m"},{"c":"Table S1C2n","t":"FRLs deemed to be achieved by floor, roof or ceiling","p":"Specification 1 Fire-resistance of building elements","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/1-fire-resistance-building-elements#_0bf991bc-6fd4-4c0f-95ed-2940dda9b0c6","x":"Floor, roof or ceiling type | Minimum thickness (mm) of principal material for FRLs\n60/60/60 | 90/90/90 | 120/120/120 | 180/180/180 | 240/240/240\nPrestressed | See clause S1C2(d)(ii)\nReinforced","tb":"S1C2","g":"/ncc/table-s1c2n"},{"c":"S1C2","t":"Rating","p":"Specification 1 Fire-resistance of building elements","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/1-fire-resistance-building-elements#S1C2","x":"A building element meets the requirements of this Specification if—\nit is listed in, and complies with Tables S1C2a, S1C2b, S1C2c, S1C2d, S1C2e, S1C2f, S1C2g, S1C2h, S1C2i, S1C2j, S1C2k, S1C2l, S1C2m or S1C2n of this Specification as applicable; or\nit is identical with a prototype that has been submitted to the Standard Fire Test, or an equivalent or more severe test, and the FRL achieved by the prototype without the assistance of an active fire suppression system is confirmed in a report from an Accredited Testing Laboratory which—\ndescribes the method and conditions of the test and the form of construction of the tested prototype in full; and\ncertifies that the application of restraint to the prototype complied with the Standard Fire Test; or\nit differs in only a minor degree from a prototype tested under (b) and the FRL attributed to the building element is confirmed in a report from an Accredited Testing Laboratory which—\ncertifies that the building element is capable of achieving the FRL despite the minor departures from the tested prototype; and\ndescribes the materials, construction and conditions of restraint which are necessary to achieve the FRL; or\nit is designed to achieve the FRL in accordance with—\nAS/NZS 2327, AS 4100 and AS/NZS 4600 if it is a steel or composite structure; or\nAS 3600 if it is a concrete structure; or\nAS 1720.4 if it is a timber element other than fire-protected timber; or\nAS 3700 if it is a masonry structure; or\nthe FRL is determined by calculation based on the performance of a prototype in the Standard Fire Test and confirmed in a report in accordance with S1C3; or\nfor fire-protected timber, it complies with Specification 10 where applicable.\nTable S1C2a FRLs deemed to be achieved by walls — masonry\nMasonry type\nMinimum thickness (mm) of principal material for FRLs\n60/60/60\n90/90/90\n120/120/120\n180/180/180\n240/240/240\nAshlar\n-\n-\n-\n-\n300\nCalcium silicate\nSee clause S1C2(d)(iv)\nConcrete\nFired clay\nTable Notes\nFor the purposes of this table, each element must meet the requirements of Specification 2.\nTable S1C2b FRLs deemed to be achieved by walls — concrete\nConcrete type\nMinimum thickness (mm) of principal material for FRLs\n60/60/60\n90/90/90\n120/120/120\n180/180/180\n240/240/240\nNo fines\n-\n-\n-\n150\n300\nPrestressed\nSee clause S1C2(d)(iv)\nReinforced\nPlain\n-\n-\n-\n150\n170\nTable Notes\nFor the purposes of this table, each element must meet the requirements of Specification 2.\nTable S1C2c FRLs deemed to be achieved by walls — gypsum\nGypsum type\nMinimum thickness (mm) of principal material for FRLs\n60/60/60\n90/90/90\n120/120/120\n180/180/180\n240/240/240\nSolid gypsum blocks\n75\n90\n100\n110\n125\nGypsum — perlite or gypsum vermiculite-plaster on metal lath and channel (non-load bearing walls only)\n50\n50\n65\n-\n-\nTable Notes\nFor the purposes of this table, each element must meet the requirements of Specification 2.\nTable S1C2d FRLs deemed to be achieved by concrete columns\nColumn type\nMinimum thickness (mm) of principal material for FRLs\n60/60/60\n90/90/90\n120/120/120\n180/180/180\n240/240/240\nPrestressed\nSee clause S1C2(d)(ii)\nReinforced\nTable S1C2e FRLs deemed to be achieved by hot-rolled steel columns (including a fabricated column) exposed on not more than 3 sides\nFire protection\nMinimum thickness (mm) of principal material for FRLs\n60/60/60\n90/90/90\n120/120/120\n180/180/180\n240/240/240\nConcrete cast in-situ — load bearing\n25\n30\n40\n55\n75\nConcrete cast in-situ — non-load bearing unplastered\n25\n30\n40\n50\n75\nConcrete cast in-situ — non-load bearing plastered 13 mm\n25\n25\n30\n40\n50\nGypsum cast in-situ\n-\n-\n-\n-\n50\nGypsum — perlite or gypsum-vermiculite plaster—sprayed to contour\n20\n25\n35\n50\n55\nGypsum — perlite or gypsum-vermiculite plaster—sprayed on metal lath\n20\n20\n25\n35\n45\nTable Notes\nFor the purposes of this table, each element must meet the requirements of Specification 2.\nTable S1C2f FRLs deemed to be achieved by hot-rolled steel columns (including a fabricated column) exposed on no more than 3 sides and with column spaces filled\nFire protection\nMinimum thickness (mm) of principal material for FRLs\n60/60/60\n90/90/90\n120/120/120\n180/180/180\n240/240/240\nSolid calcium-silicate masonry\n50\n50\n50\n50\n65\nSolid clay masonry\n50\n50\n50\n65\n90\nSolid concrete masonry\n50\n50\n50\n65\n90\nSolid gypsum blocks\n50\n50\n50\n50\n65\nHollow terracotta blocks — plastered 13 mm\n50\n50\n50\n65\n90\nTable Notes\nFor the purposes of this table, each element must meet the requirements of Specification 2.\nTable S1C2g FRLs deemed to be achieved by hot-rolled steel columns (including a fabricated column) exposed on no more than 3 sides and with column spaces unfilled\nFire protection\nMinimum thickness (mm) of principal material for FRLs\n60/60/60\n90/90/90\n120/120/120\n180/180/180\n240/240/240\nSolid calcium-silicate masonry\n50\n50\n50\n-\n-\nSolid clay masonry\n50\n50\n65\n-\n-\nSolid concrete masonry\n50\n50\n65\n-\n-\nSolid gypsum blocks\n50\n50\n50\n-\n-\nHollow terracotta blocks — plastered 13 mm\n50\n50\n65\n-\n-\nTable Notes\nFor the purposes of this table, each element must meet the requirements of Specification 2.\nTable S1C2h FRLs deemed to be achieved by hot-rolled steel columns (including a fabricated column) exposed on no more than 4 sides\nFire protection\nMinimum thickness (mm) of principal material for FRLs\n60/–/–\n90/–/–\n120/–/–\n180/–/–\n240/–/–\nConcrete cast in-situ — load bearing\n25\n40\n45\n65\n90\nConcrete cast in-situ — non-load bearing unplastered\n25\n30\n40\n50\n65\nConcrete cast in-situ — non-load bearing plastered 13 mm\n25\n25\n30\n40\n50\nGypsum cast in-situ\n-\n-\n-\n-\n50\nGypsum — perlite or gypsum-vermiculite plaster — sprayed to contour\n25\n30\n40\n55\n65\nGypsum — perlite or gypsum-vermiculite plaster — sprayed on metal lath\n20\n20\n30\n40\n50\nTable Notes\nFor the purposes of this table, each element must meet the requirements of Specification 2.\nTable S1C2i FRLs deemed to be achieved by hot-rolled steel columns (including a fabricated column) exposed on no more than 4 sides and with column spaces filled\nFire protection\nMinimum thickness (mm) of principal material for FRLs\n60/–/–\n90/–/–\n120/–/–\n180/–/–\n240/–/–\nSolid calcium-silicate masonry\n50\n50\n50\n65\n75\nSolid clay masonry\n50\n50\n50\n75\n100\nSolid concrete masonry\n50\n50\n50\n75\n100\nSolid gypsum blocks\n50\n50\n50\n65\n75\nHollow terracotta blocks — plastered 13 mm\n50\n50\n50\n75\n100\nTable Notes\nFor the purposes of this table, each element must meet the requirements of Specification 2.\nTable S1C2j FRLs deemed to be achieved by hot-rolled steel columns (including a fabricated column) exposed on no more than 4 sides and with column spaces unfilled\nFire protection\nMinimum thickness (mm) of principal material for FRLs\n60/–/–\n90/–/–\n120/–/–\n180/–/–\n240/–/–\nSolid calcium-silicate masonry\n50\n50\n50\n-\n-\nSolid clay masonry\n50\n50\n65\n-\n-\nSolid concrete masonry\n50\n50\n65\n-\n-\nSolid gypsum blocks\n50\n50\n50\n-\n-\nHollow terracotta blocks — plastered 13 mm\n50\n50\n65\n-\n-\nTable Notes\nFor the purposes of this table, each element must meet the requirements of Specification 2.\nTable S1C2k FRLs deemed to be achieved by concrete beams\nConcrete type\nMinimum thickness (mm) of principal material for FRLs\n60/–/–\n90/–/–\n120/–/–\n180/–/–\n240/–/–\nPrestressed\nSee clause S1C2(d)(ii)\nReinforced\nTable S1C2l FRLs deemed to be achieved by hot-rolled steel beams (including an open-web joist, girder, truss, etc.) exposed on no more than 3 sides\nFire protection\nMinimum thickness (mm) of principal material for FRLs\n60/–/–\n90/–/–\n120/–/–\n180/–/–\n240/–/–\nConcrete — cast in-situ\n25\n30\n40\n50\n65\nGypsum — perlite or gypsum-vermiculite plaster — sprayed to contour\n20\n25\n35\n50\n55\nGypsum — perlite or gypsum-vermiculite plaster — sprayed on metal lath\n20\n20\n25\n35\n45\nTable Notes\nFor the purposes of this table, each element must meet the requirements of Specification 2.\nTable S1C2m FRLs deemed to be achieved by hot-rolled steel beams (including an open-web joist, girder, truss, etc.) exposed on 4 sides\nFire protection\nMinimum thickness (mm) of principal material for FRLs\n60/–/–\n90/–/–\n120/–/–\n180/–/–\n240/–/–\nConcrete — cast in-situ\n25\n40\n45\n60\n90\nGyp","g":"/ncc/s1c2","a19":["Sch. 5: 2"]},{"c":"S1C3","t":"FRLs determined by calculation","p":"Specification 1 Fire-resistance of building elements","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/1-fire-resistance-building-elements#S1C3","x":"If the FRL of a building element is determined by calculation based on a tested prototype—\nthe building element may vary from the prototype in relation to—\nlength and height if it is a wall; and\nheight if it is a column; and\nspan if it is a floor, roof or beam; and\nconditions of support; and\nto a minor degree, cross-section and components; and\nthe report must demonstrate by calculation that the building element would achieve the FRL if it is subjected to the regime of the Standard Fire Test in relation to—\nstructural adequacy (including deflection); and\nintegrity; and\ninsulation; and\nthe calculations must take into account—\nthe temperature reached by the components of the prototype and their effects on strength and modulus of elasticity; and\nappropriate features of the building element such as support, restraint, cross-sectional shape, length, height, span, slenderness ratio, reinforcement, ratio of surface area to mass per unit length, and fire protection; and\nfeatures of the prototype that influenced its performance in the Standard Fire Test although these features may not have been taken into account in the design for dead and live load; and\nfeatures of the conditions of test, the manner of support and the position of the prototype during the test, that might not be reproduced in the building element if it is exposed to fire; and\nthe design load of the building element in comparison with the tested prototype.","g":"/ncc/s1c3","a19":["Sch. 5: 3"]},{"c":"S1C4","t":"Interchangeable materials","p":"Specification 1 Fire-resistance of building elements","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/1-fire-resistance-building-elements#S1C4","x":"(1) Concrete and plaster — An FRL achieved with any material of Group A, B, C, D or E as an ingredient in concrete or plaster, applies equally when any other material of the same group is used in the same proportions:\nGroup A: any portland cement.\nGroup B: any lime.\nGroup C: any dense sand.\nGroup D: any dense calcareous aggregate, including any limestone or any calcareous gravel.\nGroup E: any dense siliceous aggregate, including any basalt, diorite, dolerite, granite, granodiorite or trachyte.\n(2) Perlite and vermiculite — An FRL achieved with either gypsum-perlite plaster or gypsum-vermiculite plaster applies equally for each plaster.","g":"/ncc/s1c4","a19":["Sch. 5: 4"]},{"c":"S1C5","t":"Columns covered with lightweight construction","p":"Specification 1 Fire-resistance of building elements","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/1-fire-resistance-building-elements#S1C5","x":"If the fire-resisting covering of a steel column is lightweight construction, the construction must comply with Volume One C2D9 and C4D17.","g":"/ncc/s1c5","a19":["Sch. 5: 5"]},{"c":"S1C6","t":"Non-loadbearing elements","p":"Specification 1 Fire-resistance of building elements","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/1-fire-resistance-building-elements#S1C6","x":"If a non-load bearing element is able to be used for a purpose where the Deemed-to-Satisfy Provisions prescribe an FRL for structural adequacy, integrity and insulation, that non-load bearing element need not comply with the structural adequacy criteria.","g":"/ncc/s1c6","a19":["Sch. 5: 6"]},{"c":"S2C1","t":"Scope","p":"Specification 2 Descriptions of elements referred to in Specification 1","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/2-descriptions-elements-referred-specification-1#S2C1","x":"This Specification sets out the descriptions of elements referred to in Tables S1C2a, S1C2b, S1C2c, S1C2e, S1C2f, S1C2g, S1C2h, S1C2i, S1C2j, S1C2l and S1C2m of Specification 1.","g":"/ncc/s2c1"},{"c":"S2C2","t":"Mortar for masonry","p":"Specification 2 Descriptions of elements referred to in Specification 1","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/2-descriptions-elements-referred-specification-1#S2C2","x":"Masonry units of ashlar, calcium silicate, concrete or fired clay (including terracotta blocks) must be laid in cement mortar or composition mortar complying with the relevant provisions of AS 3700.","g":"/ncc/s2c2","a19":["Sch. 5 (Annex): 1.1"]},{"c":"S2C3","t":"Gypsum blocks","p":"Specification 2 Descriptions of elements referred to in Specification 1","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/2-descriptions-elements-referred-specification-1#S2C3","x":"Gypsum blocks must be laid in gypsum-sand mortar or lime mortar.","g":"/ncc/s2c3","a19":["Sch. 5 (Annex): 1.2"]},{"c":"S2C4","t":"Gypsum-sand mortar and plaster","p":"Specification 2 Descriptions of elements referred to in Specification 1","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/2-descriptions-elements-referred-specification-1#S2C4","x":"Gypsum-sand mortar and gypsum-sand plaster must consist of either—\nnot more than 3 parts by volume of sand to 1 part by volume of gypsum; or\nif lime putty is added, not more than 2.5 parts by volume of sand to 1 part by volume of gypsum and not more than 5% of lime putty by volume of the mixed ingredients.","g":"/ncc/s2c4","a19":["Sch. 5 (Annex): 1.3"]},{"c":"S2C5","t":"Gypsum-perlite and gypsum-vermiculite plaster","p":"Specification 2 Descriptions of elements referred to in Specification 1","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/2-descriptions-elements-referred-specification-1#S2C5","x":"Gypsum-perlite or gypsum-vermiculite plaster must be applied—\nin either one or 2 coats each in the proportions of 1 m3 of perlite or vermiculite to 640 kg of gypsum if the required thickness of the plaster is not more than 25 mm; and\nin 2 coats if the required thickness is more than 25 mm, the first in the proportions of 1 m3 of perlite or vermiculite to 800 kg of gypsum and the second in the proportions of 1 m3 of perlite or vermiculite to 530 kg of gypsum.","g":"/ncc/s2c5","a19":["Sch. 5 (Annex): 1.4"]},{"c":"S2C6","t":"Plaster of cement and sand or cement, lime and sand","p":"Specification 2 Descriptions of elements referred to in Specification 1","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/2-descriptions-elements-referred-specification-1#S2C6","x":"Plaster prescribed in Tables S1C2c, S1C2e, S1C2f, S1C2g, S1C2h, S1C2i, S1C2j, S1C2l and S1C2m —\nmust consist of cement and sand or cement, lime and sand; and\nmay be finished with gypsum, gypsum-sand, gypsum-perlite or gypsum-vermiculite plaster or with lime putty.","g":"/ncc/s2c6","a19":["Sch. 5 (Annex): 1.5"]},{"c":"S2C7","t":"Plaster reinforcement","p":"Specification 2 Descriptions of elements referred to in Specification 1","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/2-descriptions-elements-referred-specification-1#S2C7","x":"If plaster used as fire protection on walls is more than 19 mm thick—\nit must be reinforced with expanded metal lath that—\nhas a mass per unit area of not less than 1.84 kg/m2; and\nhas not fewer than 98 meshes per metre; and\nis protected against corrosion by galvanising or other suitable method; or\nit must be reinforced with 13 mm x 13 mm x 0.7 mm galvanised steel wire mesh securely fixed at a distance from the face of the wall of not less than ⅓ of the total thickness of the plaster.","g":"/ncc/s2c7","a19":["Sch. 5 (Annex): 1.6"]},{"c":"S2C8","t":"Ashlar stone masonry","p":"Specification 2 Descriptions of elements referred to in Specification 1","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/2-descriptions-elements-referred-specification-1#S2C8","x":"Ashlar masonry must not be used in a part of the building containing more than 2 storeys, and must not be of—\naplite, granite, granodiorite, quartz dacite, quartz diorite, quartz porphyrite or quartz porphyry; or\nconglomerate, quartzite or sandstone; or\nchert or flint; or\nlimestone or marble.","g":"/ncc/s2c8","a19":["Sch. 5 (Annex): 2"]},{"c":"S2C9","t":"Dimensions of masonry","p":"Specification 2 Descriptions of elements referred to in Specification 1","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/2-descriptions-elements-referred-specification-1#S2C9","x":"The thicknesses of masonry of calcium-silicate, concrete and fired clay are calculated as set out in S2C10 to S2C12.","g":"/ncc/s2c9","a19":["Sch. 5 (Annex): 3"]},{"c":"S2C10","t":"Solid units","p":"Specification 2 Descriptions of elements referred to in Specification 1","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/2-descriptions-elements-referred-specification-1#S2C10","x":"For masonry in which the amount of perforation or coring of the units does not exceed 25% by volume (based on the overall rectangular shape of the unit) the thickness of the wall must be calculated from the manufacturing dimensions of the units and the specified thickness of the joints between them as appropriate.","g":"/ncc/s2c10","a19":["Sch. 5 (Annex): 3.1"]},{"c":"S2C11","t":"Hollow units","p":"Specification 2 Descriptions of elements referred to in Specification 1","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/2-descriptions-elements-referred-specification-1#S2C11","x":"For masonry in which the amount of perforation or coring of the units exceeds 25% by volume (based on the overall rectangular shape of the unit) the thickness of the wall must be calculated from the equivalent thicknesses of the units and the specified thickness of the joints between them as appropriate.","g":"/ncc/s2c11","a19":["Sch. 5 (Annex): 3.2"]},{"c":"S2C12","t":"Equivalent thickness","p":"Specification 2 Descriptions of elements referred to in Specification 1","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/2-descriptions-elements-referred-specification-1#S2C12","x":"The equivalent thickness of a masonry unit is calculated by dividing the net volume by the area of one vertical face.","g":"/ncc/s2c12","a19":["Sch. 5 (Annex): 3.3"]},{"c":"S2C13","t":"Height-to-thickness ratio of certain walls","p":"Specification 2 Descriptions of elements referred to in Specification 1","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/2-descriptions-elements-referred-specification-1#S2C13","x":"The ratio of height between lateral supports to overall thickness of a wall of ashlar, no-fines concrete, unreinforced concrete, solid gypsum blocks, gypsum-perlite or gypsum-vermiculite plaster on metal lath and channel, must not exceed—\n20 for a load bearing wall; or\n27 for a non-load bearing wall.","g":"/ncc/s2c13","a19":["Sch. 5 (Annex): 5"]},{"c":"S2C14","t":"Increase in thickness by plastering — walls","p":"Specification 2 Descriptions of elements referred to in Specification 1","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/2-descriptions-elements-referred-specification-1#S2C14","x":"If a wall of ashlar, solid gypsum blocks or concrete is plastered on both sides to an equal thickness, the thickness of the wall for the purposes of Tables S1C2b and S1C2c (but not for the purposes of S2C5) may be increased by the thickness of the plaster on one side.","g":"/ncc/s2c14","a19":["Sch. 5 (Annex): 6.1"]},{"c":"S2C15","t":"Increase in thickness by plastering — columns","p":"Specification 2 Descriptions of elements referred to in Specification 1","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/2-descriptions-elements-referred-specification-1#S2C15","x":"(1) Where Tables S1C2e, S1C2f, S1C2g, S1C2h, S1C2i and S1C2j indicate that column-protection is to be plastered, the tabulated thicknesses are those of the principal material.\n(2) The thicknesses referred to in (1) do not include the thickness of plaster, which must be additional to the listed thickness of the material to which it is applied.","g":"/ncc/s2c15","a19":["Sch. 5 (Annex): 6.2"]},{"c":"S2C16","t":"Gypsum-perlite or gypsum-vermiculite plaster or metal lath — walls","p":"Specification 2 Descriptions of elements referred to in Specification 1","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/2-descriptions-elements-referred-specification-1#S2C16","x":"In walls fabricated of gypsum-perlite or gypsum-vermiculite plaster on metal lath and channel—\nthe lath must be securely wired to each side of 19 mm x 0.44 kg/m steel channels (used as studs) spaced at not more than 400 mm centres; and\nthe gypsum-perlite or gypsum-vermiculite plaster must be applied symmetrically to each exposed side of the lath.","g":"/ncc/s2c16","a19":["Sch. 5 (Annex): 7.1"]},{"c":"S2C17","t":"Gypsum-perlite or gypsum-vermiculite plaster or metal lath — columns","p":"Specification 2 Descriptions of elements referred to in Specification 1","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/2-descriptions-elements-referred-specification-1#S2C17","x":"(1) For the fire protection of steel columns with gypsum-perlite or gypsum-vermiculite on metal lath—\nthe lath must be fixed at not more than 600 mm centres vertically to steel furring channels, and—\nif the plaster is to be 35 mm thick or more — at least 12 mm clear of the column; or\nif the plaster is to be less than 35 mm thick — at least 6 mm clear of the column; or\nthe plaster may be applied to self-furring lath with furring dimples to hold it not less than 10 mm clear of the column.\n(2) For the purposes of (1), the thickness of the plaster must be measured from the back of the lath.","g":"/ncc/s2c17","a19":["Sch. 5 (Annex): 7.2"]},{"c":"S2C18","t":"Gypsum-perlite or gypsum-vermiculite plaster or metal lath — beams","p":"Specification 2 Descriptions of elements referred to in Specification 1","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/2-descriptions-elements-referred-specification-1#S2C18","x":"For the fire protection of steel beams with gypsum-perlite or gypsum-vermiculite on metal lath—\nthe lath must be fixed at not more than 600 mm centres to steel furring channels and at least 20 mm clear of the steel; and\nthe thickness of the plaster must be measured from the back of the lath.","g":"/ncc/s2c18","a19":["Sch. 5 (Annex): 7.3"]},{"c":"S2C19","t":"Exposure of columns","p":"Specification 2 Descriptions of elements referred to in Specification 1","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/2-descriptions-elements-referred-specification-1#S2C19","x":"A column incorporated in or in contact on one or more sides with a wall of solid masonry or concrete at least 100 mm thick may be considered to be exposed to fire on no more than 3 sides.","g":"/ncc/s2c19","a19":["Sch. 5 (Annex): 8.1"]},{"c":"S2C20","t":"Exposure of beams","p":"Specification 2 Descriptions of elements referred to in Specification 1","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/2-descriptions-elements-referred-specification-1#S2C20","x":"A beam, open-web joist, girder or truss in direct and continuous contact with a concrete slab or a hollow block floor or roof may be considered to be exposed to fire on no more than 3 sides.","g":"/ncc/s2c20","a19":["Sch. 5 (Annex): 8.2"]},{"c":"S2C21","t":"Filling of column spaces","p":"Specification 2 Descriptions of elements referred to in Specification 1","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/2-descriptions-elements-referred-specification-1#S2C21","x":"(1) The spaces between the fire-protective material and the steel (and any re-entrant parts of the column itself) must be filled solid with a fire-protective material like concrete, gypsum or grout.\n(2) The insides of hollow sections, including pipes, need not be filled.","g":"/ncc/s2c21","a19":["Sch. 5 (Annex): 9"]},{"c":"S2C22","t":"Hollow terracotta blocks","p":"Specification 2 Descriptions of elements referred to in Specification 1","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/2-descriptions-elements-referred-specification-1#S2C22","x":"The proportion of cored holes or perforations in a hollow terracotta block (based on the overall rectangular volume of the unit) must not exceed the following:\nFor blocks up to 75 mm thick — 35%.\nFor blocks more than 75 mm but not more than 100 mm thick — 40%.\nFor blocks more than 100 mm — 50%.","g":"/ncc/s2c22","a19":["Sch. 5 (Annex): 10"]},{"c":"S2C23","t":"Reinforcing for column and beam protection — masonry","p":"Specification 2 Descriptions of elements referred to in Specification 1","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/2-descriptions-elements-referred-specification-1#S2C23","x":"Masonry of calcium-silicate, fired clay and concrete for the protection of steel columns must have steel-wire or mesh reinforcement in every second course and lapped at the corners.","g":"/ncc/s2c23","a19":["Sch. 5 (Annex): 11.1"]},{"c":"S2C24","t":"Reinforcing for column and beam protection — gypsum blocks and hollow terracotta blocks","p":"Specification 2 Descriptions of elements referred to in Specification 1","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/2-descriptions-elements-referred-specification-1#S2C24","x":"Gypsum blocks and hollow terracotta blocks for the protection of steel columns must have steel-wire or mesh reinforcement in every course and lapped at corners.","g":"/ncc/s2c24","a19":["Sch. 5 (Annex): 11.2"]},{"c":"S2C25","t":"Reinforcing for column and beam protection — structural concrete and poured gypsum","p":"Specification 2 Descriptions of elements referred to in Specification 1","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/2-descriptions-elements-referred-specification-1#S2C25","x":"If a steel column or a steel beam is to be protected with structural concrete or poured gypsum, the concrete or gypsum must be reinforced with steel-wire mesh or steel-wire binding placed about 20 mm from its outer surface, and—\nfor concrete or gypsum less than 50 mm thick, the steel wire must be—\nat least 3.15 mm in diameter; and\nspaced at not more than 100 mm vertically; or\nfor concrete or gypsum not less than 50 mm thick, the steel wire must be either—\nof a diameter and spacing in accordance with (a); or\nat least 5 mm in diameter and spaced at not more than 150 mm vertically.","g":"/ncc/s2c25","a19":["Sch. 5 (Annex): 11.3"]},{"c":"Table S2C26a","t":"Reinforcement of gypsum-perlite or gypsum-vermiculite plaster sprayed to contour — vertical members with H or I cross-section","p":"Specification 2 Descriptions of elements referred to in Specification 1","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/2-descriptions-elements-referred-specification-1#_78e120e0-9318-4761-bd61-b8b09bd6c700","x":"Surface to be protected | Reinforcement required if smaller dimension of surface exceeds (mm) | Max spacing of fixings of the mesh to surface (mm)\nVertical | 450 | 450\nNon-vertical | 300 | 300\nUnderside | 300 | 300\nUpper side of a horizontal surface | Not required | N/A","tb":"S2C26","g":"/ncc/table-s2c26a"},{"c":"Table S2C26b","t":"Reinforcement of gypsum-perlite or gypsum-vermiculite plaster sprayed to contour — vertical members with other shapes","p":"Specification 2 Descriptions of elements referred to in Specification 1","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/2-descriptions-elements-referred-specification-1#_87cbd649-e98a-4d1f-914f-4611e83ad3f5","x":"Surface to be protected | Reinforcement required if smaller dimensions of surface exceeds (mm) | Max spacing of fixings of the mesh to surface (mm)\nVertical | Any size | 450\nNon-vertical | Any size | 300\nUndersize | Any size | 300\nUpper side of a horizontal surface | Not required | N/A","tb":"S2C26","g":"/ncc/table-s2c26b"},{"c":"S2C26","t":"Reinforcing for column and beam protection — gypsum-perlite or gypsum-vermiculite plaster sprayed to contour","p":"Specification 2 Descriptions of elements referred to in Specification 1","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/2-descriptions-elements-referred-specification-1#S2C26","x":"(1) If a steel column or steel beam is protected with either gypsum-perlite or gypsum-vermiculite plaster sprayed to contour and the construction falls within the limits of Table S2C26a or S2C26b, the plaster must be reinforced with—\nexpanded metal lath complying with S2C7; or\ngalvanised steel wire mesh complying with S2C7.\n(2) The reinforcement must be placed at a distance from the face of the plaster of at least 1/3 of the thickness of the plaster and must be securely fixed to the column or beam at intervals of not more than the relevant listing in Tables S2C26a and S2C26b.\n(3) For the purposes of Tables S2C26a and S2C26b —\n“vertical” includes a surface at not more than 10º to the vertical; and\n“horizontal” includes a surface at not more than 10º to the horizontal; and\n“underside” means the underside of any horizontal or non-vertical surface.\nTable S2C26a Reinforcement of gypsum-perlite or gypsum-vermiculite plaster sprayed to contour — vertical members with H or I cross-section\nSurface to be protected\nReinforcement required if smaller dimension of surface exceeds (mm)\nMax spacing of fixings of the mesh to surface (mm)\nVertical\n450\n450\nNon-vertical\n300\n300\nUnderside\n300\n300\nUpper side of a horizontal surface\nNot required\nN/A\nTable S2C26b Reinforcement of gypsum-perlite or gypsum-vermiculite plaster sprayed to contour — vertical members with other shapes\nSurface to be protected\nReinforcement required if smaller dimensions of surface exceeds (mm)\nMax spacing of fixings of the mesh to surface (mm)\nVertical\nAny size\n450\nNon-vertical\nAny size\n300\nUndersize\nAny size\n300\nUpper side of a horizontal surface\nNot required\nN/A","g":"/ncc/s2c26","a19":["Sch. 5 (Annex): 11.4"]},{"c":"S2C27","t":"Measurement of thickness of column and beam protection","p":"Specification 2 Descriptions of elements referred to in Specification 1","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/2-descriptions-elements-referred-specification-1#S2C27","x":"The thickness of the fire protection to steel columns and steel beams (other than fire protection of gypsum-perlite or gypsum-vermiculite plaster sprayed on metal lath or sprayed to contour) is to be measured from the face or edge of the steel, from the face of a splice plate or from the outer part of a rivet or bolt, whichever is the closest to the outside of the fire-protective construction, except that—\nif the thickness of the fire protection is 40 mm or more, rivet heads may be disregarded; and\nif the thickness of the fire protection is 50 mm or more—\nany part of a bolt (other than a high-tensile bolt) may be disregarded; and\na column splice plate within 900 mm of the floor may encroach upon the fire protection by up to a ¼ of the thickness of the fire protection; and\nthe flange of a column or beam may encroach by up to 12 mm upon the thickness of the fire protection at right angles to the web if—\nthe column or beam is intended to have an FRL of 240/240/240 or 240/–/–; and\nthe flange projects 65 mm or more from the web; and\nthe thickness of the edge of the flange (inclusive of any splice plate) is not more than 40 mm.","g":"/ncc/s2c27","a19":["Sch. 5 (Annex): 12.1"]},{"c":"S3C1","t":"Scope","p":"Specification 3 Fire hazard properties","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/3-fire-hazard-properties#S3C1","x":"This Specification sets out the procedures for determining the fire hazard properties of assemblies tested to AS/NZS 1530.3.","g":"/ncc/s3c1","a19":["Sch. 6: 1"]},{"c":"S3C2","t":"General requirement","p":"Specification 3 Fire hazard properties","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/3-fire-hazard-properties#S3C2","x":"The fire hazard properties of assemblies and their ability to screen their core materials as required under Specification 7 must be determined by testing in accordance with S3C3 to S3C6.","g":"/ncc/s3c2","a19":["Sch. 6: 2.1"]},{"c":"S3C3","t":"Form of test","p":"Specification 3 Fire hazard properties","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/3-fire-hazard-properties#S3C3","x":"Tests must be carried out in accordance with—\nfor the determination of the Spread-of-Flame Index and Smoke-Developed Index — AS/NZS 1530.3; and\nfor the determination of the ability to prevent ignition and to screen its core material from free air — AS 1530.4.","g":"/ncc/s3c3","a19":["Sch. 6: 2.2"]},{"c":"S3C4","t":"Test specimens","p":"Specification 3 Fire hazard properties","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/3-fire-hazard-properties#S3C4","x":"Test specimens must incorporate—\nall types of joints; and\nall types of perforations, recesses or the like for pipes, light switches or other fittings, which are proposed to be used for the member or assembly of members in the building.","g":"/ncc/s3c4","a19":["Sch. 6: 2.3"]},{"c":"S3C5","t":"Concession","p":"Specification 3 Fire hazard properties","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/3-fire-hazard-properties#S3C5","x":"S3C4 does not apply to joints, perforations, recesses or the like that are larger than those in the proposed application and have already been tested in the particular form of construction concerned and found to comply with the conditions of the test.","g":"/ncc/s3c5","a19":["Sch. 6: 2.4"]},{"c":"S3C6","t":"Smaller specimen permitted","p":"Specification 3 Fire hazard properties","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/3-fire-hazard-properties#S3C6","x":"A testing laboratory may carry out the test specified in S3C3(b) at pilot scale if a specimen (which must be not less than 900 mm x 900 mm) will adequately represent the proposed construction in the building, but the results of that test do not apply to construction larger than limits defined by the laboratory conducting the pilot examination.","g":"/ncc/s3c6","a19":["Sch. 6: 2.5"]},{"c":"A1G1","t":"Scope of NCC Volume One","p":"Part A1 Interpreting the NCC","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/part-a1-interpreting-ncc#A1G1","x":"NCC Volume One contains the requirements for—\nall Class 2 to 9 buildings; and\naccess requirements for people with a disability in Class 1b and 10a buildings; and\ncertain Class 10b structures including access requirements for people with a disability in Class 10b swimming pools.","g":"/ncc/a1g1"},{"c":"A1G2","t":"Scope of NCC Volume Two","p":"Part A1 Interpreting the NCC","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/part-a1-interpreting-ncc#A1G2","x":"NCC Volume Two contains the requirements for—\nClass 1 and 10a buildings (other than access requirements for people with a disability in Class 1b and 10a buildings); and\ncertain Class 10b structures (other than access requirements for people with a disability in Class 10b swimming pools); and\nClass 10c private bushfire shelters.","g":"/ncc/a1g2"},{"c":"A1G3","t":"Scope of NCC Volume Three","p":"Part A1 Interpreting the NCC","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/part-a1-interpreting-ncc#A1G3","x":"(1) NCC Volume Three contains technical requirements for the design, construction, installation, replacement, repair, alteration and maintenance for plumbing and drainage systems in new and existing buildings.\n(2) NCC Volume Three applies to these systems in all classes of buildings whenever plumbing and drainage work is carried out.\n(3) NCC Volume Three additionally applies to sites where services are designed, constructed, installed, replaced, repaired, altered and maintained independently of buildings.\n(4) NCC Volume Three applies from the point of connection to the point of discharge.","g":"/ncc/a1g3"},{"c":"A1G4","t":"Interpretation","p":"Part A1 Interpreting the NCC","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/part-a1-interpreting-ncc#A1G4","x":"(1) The following components of the NCC are non-mandatory and informative:\nContent identified as “explanatory information”.\nThe “Introduction” information, located at the beginning of each Volume, Section or Part.\n(2) Words in italics must be interpreted in accordance with─\ndefinitions provided in Schedule 1, unless the contrary intention appears; and\nadditional definitions in State or Territory appendices, as appropriate.\n(3) The NCC must be interpreted and applied in accordance with the following:\nA reference to a building is a reference to an entire building or part of a building (as the case requires).\nA reference to plumbing or drainage solution, or product in Volume Three is a reference to an entire installation, system or product, or part of an installation, system or product (as the case requires).\nA reference in a Performance Requirement to “the degree necessary” means─\nthat consideration of all the criteria referred to in the Performance Requirement will determine the outcome appropriate to the circumstances; and\nthat in certain cases it may not be necessary to incorporate any specific measures to meet the relevant Performance Requirement.\nAn “Application” statement is mandatory and is provided to specify where and when a requirement or provision applies.\nA “Limitation” statement is mandatory and is provided to specify where and when the application of a requirement or provision is limited to a certain circumstance.\nAn “Exemption” statement is mandatory and is provided to specify where or when a requirement or provision does not need to be complied with.\nA “Note” is part of a provision or requirement and provides additional mandatory instructions.\nFigures in the NCC─\nare used to illustrate specific issues referenced in the associated text; and\nare not to be construed as containing all design information that is required for that particular building element or situation.\nThe definitions, symbols and abbreviations listed in Schedule 1.\n(4) A reference to a building class is a reference to all the sub-classifications of that class.\n(5) The following sub-classifications apply:\nClasses 1a and 1b are sub-classifications of Class 1.\nClasses 7a and 7b are sub-classifications of Class 7.\nClasses 9a, 9b and 9c are sub-classifications of Class 9.\nClasses 10a, 10b and 10c are sub-classifications of Class 10.\n(6) A reference to a sub-classification is solely to that sub-classification.\nNotes\nFor Volume Three, if a word is not defined in Schedule 1, the meaning (if any) attributed to it under AS/NZS 3500.0 should be used unless the contrary intention appears.","g":"/ncc/a1g4","a19":["A1.0"]},{"c":"A2G1","t":"Compliance","p":"Part A2 Compliance with the NCC","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/part-a2-compliance-ncc#A2G1","x":"(1) Compliance with the NCC is achieved by complying with—\nthe Governing Requirements of the NCC; and\nthe Performance Requirements.\n(2) Performance Requirements are satisfied by one of the following, as shown in Figure A2G1:\nPerformance Solution.\nDeemed-to-Satisfy Solution.\nA combination of (a) and (b).\nFigure A2G1 NCC compliance structure","g":"/ncc/a2g1","a19":["A2.0","A2.1"]},{"c":"A2G2","t":"Performance Solution","p":"Part A2 Compliance with the NCC","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/part-a2-compliance-ncc#A2G2","x":"(1) Subject to (5), a Performance Solution is achieved by demonstrating—\ncompliance with all relevant Performance Requirements; or\nthe solution is at least equivalent to the Deemed-to-Satisfy Provisions.\n(2) Subject to (5), a Performance Solution must be shown to comply with the relevant Performance Requirements through one or a combination of the following Assessment Methods:\nEvidence of suitability in accordance with Part A5 that shows the use of a material, product, plumbing and drainage product, form of construction or design meets the relevant Performance Requirements.\nA Verification Method including the following:\nThe Verification Methods provided in the NCC.\nOther Verification Methods, accepted by the appropriate authority that show compliance with the relevant Performance Requirements.\nExpert Judgement.\nComparison with the Deemed-to-Satisfy Provisions.\n(3) Where a Performance Requirement is satisfied entirely by a Performance Solution, in order to comply with (1) the following method must be used to determine the Performance Requirement or Performance Requirements relevant to the Performance Solution:\nIdentify the relevant Performance Requirements from the Section or Part to which the Performance Solution applies.\nIdentify Performance Requirements from other Sections or Parts that are relevant to any aspects of the Performance Solution proposed or that are affected by the application of the Performance Solution.\n(4) Where a Performance Requirement is proposed to be satisfied by a Performance Solution, the following steps must be undertaken:\nPrepare a performance-based design brief in consultation with relevant stakeholders.\nCarry out analysis, as proposed by the performance-based design brief.\nEvaluate results from (4)(b) against the acceptance criteria in the performance-based design brief.\nPrepare a final report that includes—\nall Performance Requirements and/or Deemed-to-Satisfy Provisions identified through A2G2(3) or A2G4(3) as applicable; and\nidentification of all Assessment Methods used; and\ndetails of steps (4)(a) to (4)(c); and\nconfirmation that the Performance Requirement has been met; and\ndetails of conditions or limitations, if any exist, regarding the Performance Solution.\n(5) Where compliance with B1P1(2) or H1P1(2) is proposed to be satisfied by a Performance Solution for materials included in B1D4(a) to (f) or clauses 2.2.4(d) and 2.2.4(g) to (k) of the ABCB Housing Provisions, the Performance Solution must be achieved by demonstrating the solution is at least equivalent to the Deemed-to-Satisfy Provisions.\nLimitations\nA2G2(2)(c) does not apply to demonstrating compliance with Volume One Performance Requirements B1P1(2), C1P1, C1P2, C1P3, C1P4, C1P5, C1P6, C1P7, C1P8, C1P9, D1P1, D1P2, D1P3, D1P4, D1P5, D1P6, D1P7, D1P8, D1P9, D1P10, E1P1, E1P2, E1P3, E1P4, E1P5, E1P6, E2P1, E2P2, E3P1, E3P2, E3P3, E3P4, E4P1, E4P2, E4P3 and Volume Two Performance Requirement H1P1(2), to the extent they relate to structural or fire safety.\nNotes\nA2G2(5) does not take effect until 1 year after the adoption date for NCC 2025.","g":"/ncc/a2g2","a19":["A2.2"]},{"c":"A2G3","t":"Deemed-to-Satisfy Solution","p":"Part A2 Compliance with the NCC","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/part-a2-compliance-ncc#A2G3","x":"(1) A solution that complies with the Deemed-to-Satisfy Provisions is deemed to have met the Performance Requirements.\n(2) A Deemed-to-Satisfy Solution can show compliance with the Deemed-to-Satisfy Provisions through one or more of the following Assessment Methods:\nEvidence of suitability in accordance with Part A5 that shows the use of a material, product, plumbing and drainage product, form of construction or design meets a Deemed-to-Satisfy Provision.\nExpert Judgement.","g":"/ncc/a2g3","a19":["A2.3"]},{"c":"A2G4","t":"A combination of solutions","p":"Part A2 Compliance with the NCC","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/part-a2-compliance-ncc#A2G4","x":"(1) Performance Requirements may be satisfied by using a combination of Performance Solutions and Deemed-to-Satisfy Solutions.\n(2) When using a combination of solutions, compliance can be shown through the following, as appropriate:\nA2G2 for assessment against the relevant Performance Requirements.\nA2G3 for assessment against the relevant Deemed-to-Satisfy Provisions.\n(3) Where a Performance Requirement is satisfied by a Performance Solution in combination with a Deemed-to-Satisfy Solution, in order to comply with (1), the following method must be used to determine the Performance Requirement or Performance Requirements relevant to the Performance Solution:\nIdentify the relevant Deemed-to-Satisfy Provisions of each Section or Part that are to be the subject of the Performance Solution.\nIdentify the Performance Requirements from the same Sections or Parts that are relevant to the identified Deemed-to-Satisfy Provisions.\nIdentify Performance Requirements from other Sections or Parts that are relevant to any aspects of any Performance Solution proposed or that are affected by the application of the Deemed-to-Satisfy Provisions that are the subject of the Performance Solution.","g":"/ncc/a2g4","a19":["A2.4"]},{"c":"A3G1","t":"State and Territory compliance","p":"Part A3 Application of the NCC in States and Territories","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/part-a3-application-ncc-states-and-territories#A3G1","x":"(1) For application within a particular State or Territory, the volumes of the NCC comprise inclusively of—\nSections A to G, I and J and associated schedules of Volume One; and\nSections A and H and associated schedules of Volume Two; and\nSections A to E and associated schedules of Volume Three.\n(2) State and Territory variations, additions and deletions must be complied with in conjunction with the NCC.\n(3) The NCC is subject to, and may be overridden by, State or Territory legislation.\n(4) State and Territory variations, additions and deletions are contained in the following Schedules:\nSchedule 3: Commonwealth of Australia.\nSchedule 4: Australian Capital Territory.\nSchedule 5: New South Wales.\nSchedule 6: Northern Territory.\nSchedule 7: Queensland.\nSchedule 8: South Australia.\nSchedule 9: Tasmania.\nSchedule 10: Victoria.\nSchedule 11: Western Australia.\n(5) State and Territory variations and deletions are identified throughout the NCC.","g":"/ncc/a3g1","a19":["A3.0"]},{"c":"A5G1","t":"Suitability","p":"Part A5 Documentation of design and construction","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/part-a5-documentation-design-and-construction#A5G1","x":"(1) A building and plumbing or drainage installation must be constructed using materials, products, plumbing products, forms of construction and designs fit for their intended purpose to achieve the relevant requirements of the NCC.\n(2) For the purposes of (1), a material, product, plumbing product, form of construction or design is fit for purpose if it is—\nsupported by evidence of suitability in accordance with—\nA5G2; and\nA5G3 or A5G4 as appropriate; and\nconstructed or installed in an appropriate manner.","g":"/ncc/a5g1","a19":["A5.0"]},{"c":"A5G2","t":"Evidence of suitability ─ Volumes One, Two and Three","p":"Part A5 Documentation of design and construction","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/part-a5-documentation-design-and-construction#A5G2","x":"(1) The form of evidence used must be appropriate to the use of the material, product, plumbing product, form of construction or design to which it relates.\n(2) Any copy of documentary evidence submitted must be a complete copy of the original certificate, report or document.","g":"/ncc/a5g2","a19":["A5.1"]},{"c":"A5G3","t":"Evidence of suitability ─ Volumes One and Two (BCA)","p":"Part A5 Documentation of design and construction","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/part-a5-documentation-design-and-construction#A5G3","x":"(1) Subject to A5G5, A5G6, A5G7 and A5G9, evidence to support that the use of a material, product, form of construction or design meets a Performance Requirement or a Deemed-to-Satisfy Provision may be in the form of any one, or any combination of the following:\nA current CodeMark Australia or CodeMark Certificate of Conformity.\nA current Certificate of Accreditation.\nA current certificate, other than a certificate described in (a) and (b), issued by a certification body stating that the properties and performance of a material, product, form of construction or design fulfil specific requirements of the BCA.\nA report issued by an Accredited Testing Laboratory that—\ndemonstrates that a material, product or form of construction fulfils specific requirements of the BCA; and\nsets out the tests the material, product or form of construction has been subjected to and the results of those tests and any other relevant information that has been relied upon to demonstrate it fulfils specific requirements of the BCA.\nA certificate or report from a professional engineer or other appropriately qualified person that—\ncertifies that a material, product, form of construction or design fulfils specific requirements of the BCA; and\nsets out the basis on which it is given and the extent to which relevant standards, specifications, rules, codes of practice or other publications have been relied upon to demonstrate it fulfils specific requirements of the BCA.\nAnother form of documentary evidence, such as but not limited to a Product Technical Statement, that—\ndemonstrates that a material, product, form of construction or design fulfils specific requirements of the BCA; and\nsets out the basis on which it is given and the extent to which relevant standards, specifications, rules, codes of practice or other publications have been relied upon to demonstrate it fulfils specific requirements of the BCA.\n(2) Evidence to support that a calculation method complies with an ABCB protocol may be in the form of any one, or any combination of the following:\nA certificate from a professional engineer or other appropriately qualified person that—\ncertifies that the calculation method complies with a relevant ABCB protocol; and\nsets out the basis on which it is given and the extent to which relevant standards, specifications, rules, codes of practice and other publications have been relied upon.\nAnother form of documentary evidence that correctly describes how the calculation method complies with a relevant ABCB protocol.\nApplications\nA5G3 is only applicable to NCC Volumes One and Two (BCA).\nNotes\nCurrent documentary evidence, such as a certificate or report, containing references to NCC 2019 provisions remains valid despite amended provision references in NCC 2022 and subsequent editions, subject to technical requirements remaining the same between editions.","g":"/ncc/a5g3","a19":["A5.2"]},{"c":"A5G4","t":"Evidence of suitability ─ Volume Three (PCA)","p":"Part A5 Documentation of design and construction","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/part-a5-documentation-design-and-construction#A5G4","x":"(1) Any product that is intended for use in contact with drinking water must comply with the relevant requirements of AS/NZS 4020, verified in the form of either—\na test report provided by an Accredited Testing Laboratory, in accordance with AS/NZS 4020; or\na WaterMark Licence issued in accordance with (3), if it includes compliance with AS/NZS 4020.\n(2) Any product that contains copper alloy and is intended for use in contact with drinking water must have a weighted average lead content of not more than 0.25% verified in the form of either—\na test report provided by an Accredited Testing Laboratory, in accordance with NSF/ANSI/CAN 372; or\na WaterMark Licence issued in accordance with (3), if it includes compliance with NSF/ANSI/CAN 372.\n(3) A product of a type listed on the WaterMark Schedule of Products is deemed to be fit for its intended purpose if it has a WaterMark Licence issued in accordance with the WaterMark Scheme Rules.\n(4) A product of a type listed on the Watermark Schedule of Excluded Products requires evidence of suitability in the form of—\na current certificate issued by a certification body stating that the properties and performance of a product can meet the requirements of the PCA; or\na report issued by an Accredited Testing Laboratory that—\ndemonstrates that the product complies with the relevant requirements of the PCA; and\nsets out the tests the product has been submitted to and the results of those tests and any other relevant information that has been relied upon to demonstrate suitability for use in a plumbing or drainage installation.\n(5) Any product that is not covered by (3) or (4) must be subjected to a risk assessment in accordance with the WaterMark Scheme Rules.\n(6) Evidence to support that a design or system meets the relevant PCA Performance Requirements must be in the form of any one or any combination of the following:\nThe design or system complies with a Deemed-to-Satisfy Provision.\nThe design or system is a Performance Solution from a professional engineer or a recognised expert that—\ncertifies that the design or system complies with the relevant requirements of the PCA; and\nsets out the basis on which it is given and the extent to which relevant standards, specifications, rules, codes of practice or other publications have been relied upon.\nAny other form of documentary evidence that—\ndemonstrates that a design or system complies with the relevant requirements of the PCA; and\nsets out the basis on which it is given and the extent to which relevant standards, specifications, rules, codes of practice or other publications have been relied upon.\nNotes\nOn-site wastewater management systems larger than covered by the standards are exempt and a Performance Solution is required.\nNotes\nA5G4(2) does not take effect until the completion of the transition period specified by WaterMark Notice of Direction 2021/4.\nNote 1 does not prevent the use of products certified in accordance with A5G4(2) prior to the completion of the transition period specified by the WaterMark Notice of Direction 2021/4.\nApplications\nProducts subject to the requirements of A5G4(2) are specifically nominated in the WaterMark Schedule of Products and the WaterMark Schedule of Excluded Products.\nExemptions\nProducts that are used exclusively for non-drinking uses such as manufacturing, industrial processing, irrigation or any other uses where water is not anticipated to be used for human consumption are excluded from the requirements of A5G4(2).","g":"/ncc/a5g4","a19":["A5.3"]},{"c":"A5G5","t":"Fire-resistance of building elements","p":"Part A5 Documentation of design and construction","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/part-a5-documentation-design-and-construction#A5G5","x":"Where a Deemed-to-Satisfy Provision requires a building element to have an FRL, it must be determined in accordance with Specifications 1 and 2.","g":"/ncc/a5g5","a19":["A5.4"]},{"c":"A5G6","t":"Fire hazard properties and combustibility","p":"Part A5 Documentation of design and construction","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/part-a5-documentation-design-and-construction#A5G6","x":"(1) Subject to (3), where a Deemed-to-Satisfy Provision requires a building material, component, or assembly to have a fire hazard property it must be determined as follows:\nFor critical radiant flux and smoke development rate, in accordance with AS ISO 9239.1.\nFor Smoke-Developed Index and Spread-of-Flame Index, in accordance with AS/NZS 1530.3.\nFor group number, average specific extinction area and smoke growth rate index (SMOGRARC), in accordance with AS 5637.1.\nFor Flammability Index, in accordance with AS 1530.2.\n(2) Subject to (4) and (5), where a Deemed-to-Satisfy Provision requires a building material, component, or assembly to be non-combustible, its combustibility may be determined in accordance with AS 1530.1 or C2D10(5).\n(3) A building material, component, or assembly is deemed to have a fire hazard property if—\nit is identical with a prototype that has been tested in accordance with (1) and the fire hazard property achieved by the prototype is confirmed in a report issued from an Accredited Testing Laboratory that—\ndescribes the method and conditions of the test and form of construction of the tested prototype in full; and\nconfirms that the application of restraint to the prototype complies with the test standard; or\nit differs in only a minor degree from a prototype tested under (a) and a report from an Accredited Testing Laboratory —\nconfirms that the building product, component, or assembly can achieve the fire hazard property despite the minor departures from the tested prototype; and\ndescribes the materials, construction, conditions of restraint and other limitations which are necessary to achieve the fire hazard property.\n(4) A building material is deemed to be non-combustible if—\nit is identical with a material that has been tested in accordance with AS 1530.1 and has not been deemed combustible, as confirmed in a report issued from an Accredited Testing Laboratory; or\nit is deemed non-combustible in accordance with C2D10(5); or\nit differs in only a minor degree to a material tested under (a) and a report from an Accredited Testing Laboratory —\nconfirms that the material can achieve the attribute of being non-combustible despite the minor departures from the tested material; and\ndescribes any limitations which are necessary to achieve the attribute of being non-combustible.\n(5) A building component or assembly is deemed to be non-combustible if it is constructed wholly of materials that are deemed to be non-combustible.\nNotes\nUntil adoption of the next edition of the NCC, determination need not be undertaken by an Accredited Testing Laboratory.","g":"/ncc/a5g6","a19":["A5.5"]},{"c":"A5G7","t":"Resistance to the incipient spread of fire","p":"Part A5 Documentation of design and construction","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/part-a5-documentation-design-and-construction#A5G7","x":"A ceiling is deemed to have a resistance to the incipient spread of fire to the space above itself if—\nit is identical with a prototype that has been submitted to the Standard Fire Test and the resistance to the incipient spread of fire achieved by the prototype is confirmed in a report from an Accredited Testing Laboratory that—\ndescribes the method and conditions of the test and form of construction of the tested prototype in full; and\ncertifies that the application of restraint to the prototype complies with the Standard Fire Test; or\nit differs in only a minor degree from a prototype tested under (a) and the resistance to the incipient spread of fire attributed to the ceiling is confirmed in a report from an Accredited Testing Laboratory that—\ncertifies that the ceiling is capable of achieving the resistance to the incipient spread of fire despite the minor departures from the tested prototype; and\ndescribes the materials, construction and conditions of restraint that are necessary to achieve the resistance to the incipient spread of fire.","g":"/ncc/a5g7","a19":["A5.6"]},{"c":"A5G8","t":"Labelling of Aluminium Composite Panels","p":"Part A5 Documentation of design and construction","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/part-a5-documentation-design-and-construction#A5G8","x":"An Aluminium Composite Panel must be labelled in accordance with SA TS 5344.","g":"/ncc/a5g8","a19":["A5.7"]},{"c":"A5G9","t":"NatHERS","p":"Part A5 Documentation of design and construction","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/part-a5-documentation-design-and-construction#A5G9","x":"Where house energy rating software is required to be used, evidence of the house energy rating software output must be in the form of a NatHERS certificate issued in accordance with the NatHERS scheme.","g":"/ncc/a5g9"},{"c":"A6G1","t":"Determining a building classification","p":"Part A6 Building classification","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/part-a6-building-classification#A6G1","x":"(1) The classification of a building or part of a building is determined by the purpose for which it is designed, constructed or adapted to be used.\n(2) Each part of a building must be classified according to its purpose and comply with all the appropriate requirements for its classification.\n(3) A room that contains a mechanical, thermal or electrical facility or the like that serves the building must have the same classification as the major part or principal use of the building or fire compartment in which it is situated.\n(4) Unless another classification is more suitable, an occupiable outdoor area must have the same classification as the part of the building to which it is associated.\nExemptions\nFor A6G1(1) where a part of a building has been designed, constructed or adapted for a different purpose and is less than 10% of the floor area of the storey it is situated on, the classification of the other part of the storey may apply to the whole storey.\nA6G1(3) does not apply to an electricity network substation.\nLimitations\nExemption (1) does not apply where the minor use of a building is a laboratory, a Class 9b early childhood centre, or a Class 2, 3 or 4 part of a building.","g":"/ncc/a6g1","a19":["A6.0"]},{"c":"A6G2","t":"Class 1 buildings","p":"Part A6 Building classification","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/part-a6-building-classification#A6G2","x":"(1) A Class 1 building is a dwelling.\n(2) Class 1 includes the following sub-classifications:\nClass 1a is one or more buildings, which together form a single dwelling including the following:\nA detached house.\nOne of a group of two or more attached dwellings, each being a building, separated by a fire-resisting wall, including a row house, terrace house, town house or villa unit.\nClass 1b is one or more buildings which together constitute—\na boarding house, guest house, hostel or the like that—\nwould ordinarily accommodate not more than 12 people; and\nhave a total area of all floors not more than 300 m2 (measured over the enclosing walls of the building or buildings); or\nfour or more single dwellings located on one allotment and used for short-term holiday accommodation.\nFigure A6G2a Identification of Class 1 buildings\nFigure A6G2b Typical Class 1 building configurations\nFigure A6G2c Domestic allotment — classification of buildings and structures\nNotes\nFigures A6G2a, A6G2b and A6G2c illustrate requirements of this provision.\nLimitations\nFor A6G2, a Class 1 building cannot be located above or below another dwelling or another class of building, other than a private garage.","g":"/ncc/a6g2","a19":["A6.1"]},{"c":"A6G3","t":"Class 2 buildings","p":"Part A6 Building classification","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/part-a6-building-classification#A6G3","x":"(1) A Class 2 building is a building containing two or more sole-occupancy units.\n(2) Each sole-occupancy unit in a Class 2 building must be a separate dwelling.","g":"/ncc/a6g3","a19":["A6.2"]},{"c":"A6G4","t":"Class 3 buildings","p":"Part A6 Building classification","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/part-a6-building-classification#A6G4","x":"(1) A Class 3 building is a residential building providing long-term or transient accommodation for a number of unrelated persons.\n(2) Class 3 buildings include the following:\nA boarding house, guest house, hostel, lodging house or backpacker accommodation.\nA residential part of a hotel or motel.\nA residential part of a school.\nAccommodation for the aged, children, or people with disability.\nA residential part of a health-care building which accommodates members of staff.\nA residential part of a detention centre.\nA residential care building.\nLimitations\nFor A6G4, a Class 3 building is not a Class 1 or 2 building but may be a mixture of Class 3 and another class.","g":"/ncc/a6g4","a19":["A6.3"]},{"c":"A6G5","t":"Class 4 buildings","p":"Part A6 Building classification","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/part-a6-building-classification#A6G5","x":"Class 4 is a dwelling in a Class 5, 6, 7, 8 or 9 building if it is the only dwelling in the building.","g":"/ncc/a6g5","a19":["A6.4"]},{"c":"A6G6","t":"Class 5 buildings","p":"Part A6 Building classification","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/part-a6-building-classification#A6G6","x":"A Class 5 building is an office building used for professional or commercial purposes.","g":"/ncc/a6g6","a19":["A6.5"]},{"c":"A6G7","t":"Class 6 buildings","p":"Part A6 Building classification","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/part-a6-building-classification#A6G7","x":"(1) A Class 6 building is a shop or other building used for the sale of goods by retail or the supply of services direct to the public.\n(2) Class 6 buildings include the following:\nAn eating room, cafe, restaurant, milk or soft-drink bar.\nA dining room, bar area that is not an assembly building, shop or kiosk part of a hotel or motel.\nA hairdresser’s or barber’s shop, public laundry, or undertaker’s establishment.\nA supermarket or sale room, showroom, or service station.","g":"/ncc/a6g7","a19":["NSW A6.6","SA A6.6","A6.6"]},{"c":"A6G8","t":"Class 7 buildings","p":"Part A6 Building classification","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/part-a6-building-classification#A6G8","x":"(1) A Class 7 building is a storage-type building.\n(2) Class 7 includes the following sub-classifications:\nClass 7a — a carpark.\nClass 7b — a building that is used for storage, or display of goods or produce for sale by wholesale.","g":"/ncc/a6g8","a19":["A6.7"]},{"c":"A6G9","t":"Class 8 buildings","p":"Part A6 Building classification","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/part-a6-building-classification#A6G9","x":"(1) A Class 8 building is a process-type building.\n(2) Class 8 buildings include the following:\nA laboratory.\nA building in which the production, assembling, altering, repairing, packing, finishing, or cleaning of goods or produce for sale takes place.","g":"/ncc/a6g9","a19":["A6.8"]},{"c":"A6G10","t":"Class 9 buildings","p":"Part A6 Building classification","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/part-a6-building-classification#A6G10","x":"(1) A Class 9 building is a building of a public nature.\n(2) Class 9 includes the following sub-classifications:\nClass 9a — a health-care building including any parts of the building set aside as laboratories, and includes a health-care building used as a residential care building.\nClass 9b — an assembly building including a trade workshop or laboratory in a primary or secondary school.\nClass 9c — a residential care building.\nExemptions\nA6G10(2)(b) excludes any parts of the building that are of another Class.","g":"/ncc/a6g10","a19":["A6.9"]},{"c":"A6G11","t":"Class 10 buildings and structures","p":"Part A6 Building classification","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/part-a6-building-classification#A6G11","x":"(1) A Class 10 building or structure is non-habitable.\n(2) Class 10 includes the following sub-classifications:\nClass 10a is a non-habitable building including a private garage, carport, shed or the like.\nClass 10b is a structure that is a fence, mast, antenna, retaining wall or free-standing wall or swimming pool or the like.\nClass 10c is a private bushfire shelter.","g":"/ncc/a6g11","a19":["A6.10"]},{"c":"A6G12","t":"Multiple classifications","p":"Part A6 Building classification","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/part-a6-building-classification#A6G12","x":"A building (or part of a building) may be designed, constructed or adapted for multiple purposes and have more than one classification.\nApplications\nFor A6G12, a building (or part of a building) must comply with all the relevant requirements that apply to each of the classifications for that building (or part of a building).","g":"/ncc/a6g12","a19":["A6.11"]},{"c":"A7G1","t":"United buildings","p":"Part A7 United buildings","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/part-a7-united-buildings#A7G1","x":"Buildings are deemed united when two or more buildings adjoining each other are connected and used as one building.\nApplications\nFor A7G1, two or more buildings are a united building if they are connected through openings in the walls dividing them and together comply with all the requirements of the NCC as though they are a single building.\nA7G1 only applies to Class 2 to 9 buildings.","g":"/ncc/a7g1","a19":["A7.0"]},{"c":"A7G2","t":"Alterations in a united building","p":"Part A7 United buildings","u":"/editions/ncc-2025/adopted/volume-one/a-governing-requirements/part-a7-united-buildings#A7G2","x":"If, after alterations or any other building work, two or more of the buildings in A7G1 cease to be connected through openings in the dividing walls, each of those buildings not now connected must comply with all the requirements for a single building.","g":"/ncc/a7g2","a19":["A7.1"]},{"c":"S4C1","t":"Scope","p":"Specification 4 Design of buildings in cyclonic areas","u":"/editions/ncc-2025/adopted/volume-one/b-structure/4-design-buildings-cyclonic-areas#S4C1","x":"(1) This specification contains requirements for the design of buildings in cyclonic areas in addition to the requirements of AS/NZS 1170.2.\n(2) For the purposes of Specification 4, cyclonic areas are those determined as being located in wind regions B2, C and D in accordance with AS/NZS 1170.2.","g":"/ncc/s4c1","a19":["Spec B1.2: 1"]},{"c":"Table S4C2","t":"Low-high-low pressure sequence","p":"Specification 4 Design of buildings in cyclonic areas","u":"/editions/ncc-2025/adopted/volume-one/b-structure/4-design-buildings-cyclonic-areas#_daa66bf5-5480-4645-9ea0-c15aba4b739d","x":"Sequence | Number of cycles | Load\nA | 4500 | 0 to 0.45 Pt\nB | 600 | 0 to 0.6 Pt\nC | 80 | 0 to 0.8 Pt\nD | 1 | 0 to 1.0 Pt\nE | 80 | 0 to 0.8 Pt\nF | 600 | 0 to 0.6 Pt\nG | 4500 | 0 to 0.45 Pt\nTable Notes\nPt is the ultimate limit state wind pressure on internal and external surfaces as determined in accordance with AS/NZS 1170.2, modified by an appropriate factor for variability, as determined in accordance with Table B1 of AS/NZS 1170.0.\nThe rate of load cycling must be less than 3 Hz.\nThe single load cycle (sequence D) must be held for a minimum of 10 seconds.","tb":"S4C2","g":"/ncc/table-s4c2"},{"c":"S4C2","t":"Roof cladding","p":"Specification 4 Design of buildings in cyclonic areas","u":"/editions/ncc-2025/adopted/volume-one/b-structure/4-design-buildings-cyclonic-areas#S4C2","x":"Test for strength: Metal roof cladding, its connections and immediate supporting members must be capable of remaining in position notwithstanding any permanent distortion, fracture or damage that might occur in the sheet or fastenings under the pressure sequences A to G defined in Table S4C2.\nTable S4C2 Low-high-low pressure sequence\nSequence\nNumber of cycles\nLoad\nA\n4500\n0 to 0.45 Pt\nB\n600\n0 to 0.6 Pt\nC\n80\n0 to 0.8 Pt\nD\n1\n0 to 1.0 Pt\nE\n80\n0 to 0.8 Pt\nF\n600\n0 to 0.6 Pt\nG\n4500\n0 to 0.45 Pt\nTable Notes\nPt is the ultimate limit state wind pressure on internal and external surfaces as determined in accordance with AS/NZS 1170.2, modified by an appropriate factor for variability, as determined in accordance with Table B1 of AS/NZS 1170.0.\nThe rate of load cycling must be less than 3 Hz.\nThe single load cycle (sequence D) must be held for a minimum of 10 seconds.","g":"/ncc/s4c2","a19":["Spec B1.2: 2"]},{"c":"B1O1","t":"Objective","p":"Part B1 Structural provisions","u":"/editions/ncc-2025/adopted/volume-one/b-structure/part-b1-structural-provisions#B1O1","x":"The Objective of this Part is to—\nsafeguard people from injury caused by structural failure; and\nsafeguard people from loss of amenity caused by structural behaviour; and\nprotect other property from physical damage caused by structural failure; and\nsafeguard people from injury that may be caused by failure of, or impact with, glazing.","g":"/ncc/b1o1","a19":["BO1"]},{"c":"B1F1","t":"Structure","p":"Part B1 Structural provisions","u":"/editions/ncc-2025/adopted/volume-one/b-structure/part-b1-structural-provisions#B1F1","x":"A building or structure is to withstand the combination of loads and other actions to which it may be reasonably subjected.","g":"/ncc/b1f1","a19":["BF1.1"]},{"c":"B1F2","t":"Glazing","p":"Part B1 Structural provisions","u":"/editions/ncc-2025/adopted/volume-one/b-structure/part-b1-structural-provisions#B1F2","x":"(1) Glazing is to be installed in a building to avoid undue risk of injury to people.\n(2) Glazing in a building should not cause injury to people due to its failure or people impacting with it because they did not see it.","g":"/ncc/b1f2","a19":["BF1.2"]},{"c":"Table B1P1a","t":"Minimum annual reliability indices (β) for additive load combinations (gravity actions only)","p":"Part B1 Structural provisions","u":"/editions/ncc-2025/adopted/volume-one/b-structure/part-b1-structural-provisions#_4022ab56-ab3c-4927-ab33-c03017c7b902","x":"All Importance Levels\nβ = 4.30\nTable Notes\nThe annual reliability indices in Table B1P1a must be met for all components necessary to comply with B1P1(1) at the relevant Importance Level.\nAncillary components may have a reliability index appropriate to the component, but not less than that required for Importance Level 1, irrespective of the Importance Level of the whole building or structure.","tb":"B1P1","g":"/ncc/table-b1p1a"},{"c":"Table B1P1b","t":"Minimum annual reliability indices (β) for additive load combinations (combined gravity and other actions)","p":"Part B1 Structural provisions","u":"/editions/ncc-2025/adopted/volume-one/b-structure/part-b1-structural-provisions#_808b15d6-7c4c-4f1c-9beb-b2e2199a0957","x":"Importance Level 1 | Importance Level 2 | Importance Level 3 | Importance Level 4\nβ = 3.45 | β = 3.70 | β = 3.85 | β = 4.00\nTable Notes\nThe annual reliability indices in Table B1P1b must be met for all components necessary to comply with B1P1(1) at the relevant Importance Level.\nAncillary components may have a reliability index appropriate to the component, but not less than that required for Importance Level 1, irrespective of the Importance Level of the whole building or structure.","tb":"B1P1","g":"/ncc/table-b1p1b"},{"c":"Table B1P1c","t":"Minimum annual reliability indices (β) for action reversal and stability load combinations (combined gravity and other actions)","p":"Part B1 Structural provisions","u":"/editions/ncc-2025/adopted/volume-one/b-structure/part-b1-structural-provisions#_4712e95f-3c0c-47e2-8a8b-52658d6c3706","x":"Importance Level 1 | Importance Level 2 | Importance Level 3 | Importance Level 4\nβ = 3.00 | β = 3.35 | β = 3.55 | β = 3.65\nTable Notes\nThe annual reliability indices in Table B1P1c must be met for all components necessary to comply with B1P1(1) at the relevant Importance Level.\nAncillary components may have a reliability index appropriate to the component, but not less than that required for Importance Level 1, irrespective of the Importance Level of the whole building or structure.","tb":"B1P1","g":"/ncc/table-b1p1c"},{"c":"Table B1P1d","t":"Importance Levels of buildings and structures","p":"Part B1 Structural provisions","u":"/editions/ncc-2025/adopted/volume-one/b-structure/part-b1-structural-provisions#_a23f9d55-45f0-4d47-a96f-9d928f4b5471","x":"Importance Level | Building Types\n1 | Buildings or structures presenting a low degree of hazard to life and other property in the case of failure.\n2 | Buildings or structures not included in Importance Level 1, 3 and 4.\n3 | Buildings or structures that are designed to contain a large number of people.\n4 | Buildings or structures that are essential to post-disaster recovery or associated with hazardous facilities.","tb":"B1P1","g":"/ncc/table-b1p1d"},{"c":"B1P1","t":"Structural reliability","p":"Part B1 Structural provisions","u":"/editions/ncc-2025/adopted/volume-one/b-structure/part-b1-structural-provisions#B1P1","x":"(1) By resisting the actions to which it may reasonably be expected to be subjected, a building or structure, during construction and use, with appropriate levels of reliability, must—\nperform adequately under all reasonably expected design actions; and\nwithstand extreme or frequently repeated design actions; and\nbe designed to sustain local damage, with the structural system as a whole remaining stable and not being damaged to an extent disproportionate to the original local damage; and\navoid causing damage to other properties.\n(2) Each component of the building or structure must withstand all actions with the minimum levels of reliability specified in Tables B1P1a, B1P1b and B1P1c as determined in accordance with B1V1.\n(3) The actions to be considered to satisfy (1) and (2) include but are not limited to—\npermanent actions (dead loads) including, for a Class 7b building, an additional notional permanent roof load of not less than 0.15 kPa to support the addition of solar photovoltaic panels; and\nimposed actions (live loads arising from occupancy and use); and\nwind action; and\nearthquake action; and\nsnow action; and\nliquid pressure action; and\nground water action; and\nrainwater action (including ponding action); and\nearth pressure action; and\ndifferential movement; and\ntime dependent effects (including creep and shrinkage); and\nthermal effects; and\nground movement caused by—\nswelling, shrinkage or freezing of the subsoil; and\nlandslip or subsidence; and\nsiteworks associated with the building or structure; and\nconstruction activity actions; and\ntermite actions.\n(4) The structural resistance of materials and forms of construction must be determined using material properties with appropriate allowance for the type and use of the material and the degree of accuracy inherent in the methods used to assess the structural behaviour.\n(5) For the purposes of B1P1(2), Importance Level must be assigned in accordance with Table B1P1d.\nTable B1P1a Minimum annual reliability indices (β) for additive load combinations (gravity actions only)\nAll Importance Levels\nβ = 4.30\nTable Notes\nThe annual reliability indices in Table B1P1a must be met for all components necessary to comply with B1P1(1) at the relevant Importance Level.\nAncillary components may have a reliability index appropriate to the component, but not less than that required for Importance Level 1, irrespective of the Importance Level of the whole building or structure.\nTable B1P1b Minimum annual reliability indices (β) for additive load combinations (combined gravity and other actions)\nImportance Level 1\nImportance Level 2\nImportance Level 3\nImportance Level 4\nβ = 3.45\nβ = 3.70\nβ = 3.85\nβ = 4.00\nTable Notes\nThe annual reliability indices in Table B1P1b must be met for all components necessary to comply with B1P1(1) at the relevant Importance Level.\nAncillary components may have a reliability index appropriate to the component, but not less than that required for Importance Level 1, irrespective of the Importance Level of the whole building or structure.\nTable B1P1c Minimum annual reliability indices (β) for action reversal and stability load combinations (combined gravity and other actions)\nImportance Level 1\nImportance Level 2\nImportance Level 3\nImportance Level 4\nβ = 3.00\nβ = 3.35\nβ = 3.55\nβ = 3.65\nTable Notes\nThe annual reliability indices in Table B1P1c must be met for all components necessary to comply with B1P1(1) at the relevant Importance Level.\nAncillary components may have a reliability index appropriate to the component, but not less than that required for Importance Level 1, irrespective of the Importance Level of the whole building or structure.\nTable B1P1d Importance Levels of buildings and structures\nImportance Level\nBuilding Types\n1\nBuildings or structures presenting a low degree of hazard to life and other property in the case of failure.\n2\nBuildings or structures not included in Importance Level 1, 3 and 4.\n3\nBuildings or structures that are designed to contain a large number of people.\n4\nBuildings or structures that are essential to post-disaster recovery or associated with hazardous facilities.\nExemptions\nThe requirement for an additional notional permanent roof load to support photovoltaic panels in B1P1(3)(a) does not apply to a Class 7b building—\nwhere 100% of the roof area is shaded for more than 70% of daylight hours; or\nwith a roof area of not more than 55 m2; or\nwhere more than 50% of the roof area is used as a terrace, carpark, roof garden, roof light or the like.\nNotes\nB1P1(2) does not take effect until 1 year after the adoption date for NCC 2025.\nNotes\nWhen assessing compliance with B1P1(3)(a) to (e), the actions must include those from the relevant part of AS/NZS 1170 series of Standards.","g":"/ncc/b1p1","a19":["BP1.1"]},{"c":"B1P2","t":"Glass installations at risk of human impact","p":"Part B1 Structural provisions","u":"/editions/ncc-2025/adopted/volume-one/b-structure/part-b1-structural-provisions#B1P2","x":"Glass installations that are at risk of being subjected to human impact must have glazing that—\nif broken on impact, will break in a way that is not likely to cause injury to people; and\nresists a reasonably foreseeable human impact without breaking; and\nis protected or marked in a way that will reduce the likelihood of human impact.","g":"/ncc/b1p2","a19":["BP1.2"]},{"c":"B1P3","t":"Buildings in flood areas","p":"Part B1 Structural provisions","u":"/editions/ncc-2025/adopted/volume-one/b-structure/part-b1-structural-provisions#B1P3","x":"(1) A building in a flood hazard area, must be designed and constructed, to the degree necessary, to resist flotation, collapse or significant permanent movement resulting from the action of hydrostatic, hydrodynamic, erosion and scour, wind and other actions during the defined flood event.\n(2) The actions and requirements to be considered to satisfy (1) include but are not limited to—\nflood actions; and\nelevation requirements; and\nfoundation and footing requirements; and\nrequirements for enclosures below the flood hazard level; and\nrequirements for structural connections; and\nmaterial requirements; and\nrequirements for utilities; and\nrequirements for occupant egress.\nApplications\nB1P3 only applies to—\na Class 2 or 3 building or a Class 4 part of a building; and\na Class 9a health-care building; and\na Class 9c building.","g":"/ncc/b1p3","a19":["BP1.3"]},{"c":"Table B1V1a","t":"Annual action models","p":"Part B1 Structural provisions","u":"/editions/ncc-2025/adopted/volume-one/b-structure/part-b1-structural-provisions#_aa6f3007-22b7-4f7c-9119-2d0e3a69634d","x":"Design action | Ratio of mean action to nominal | Coefficient of variation of the action\nPermanent action | 1.05 | 0.10\nAnnual maximum imposed action | 0.35 | 0.45\nArbitrary-point-in-time imposed action | 0.25 | 0.78\nWind (non-cyclonic regions, Importance Level 1) | 0.37 | 0.47\nWind (non-cyclonic regions, Importance Level 2) | 0.31 | 0.47\nWind (non-cyclonic regions, Importance Level 3) | 0.29 | 0.47\nWind (non-cyclonic regions, Importance Level 4) | 0.27 | 0.47\nWind (cyclonic regions, Importance Level 1) | 0.19 | 0.76\nWind (cyclonic regions, Importance Level 2) | 0.16 | 0.76\nWind (cyclonic regions, Importance Level 3) | 0.14 | 0.76\nWind (cyclonic regions, Importance Level 4) | 0.13 | 0.76\nEarthquake (Importance Level 1) | 0.28 | 0.90\nEarthquake (Importance Level 2) | 0.15 | 0.90\nEarthquake (Importance Level 3) | 0.12 | 0.90\nEarthquake (Importance Level 4) | 0.084 | 0.90\nSnow | 0.29 | 0.57\nTable Notes\nActions not listed must be considered and derived on a case-by-case basis.\nNominal loads are based on AS/NZS 1170 series of standards.","tb":"B1V1","g":"/ncc/table-b1v1a"},{"c":"B1V1","t":"Structural reliability of components","p":"Part B1 Structural provisions","u":"/editions/ncc-2025/adopted/volume-one/b-structure/part-b1-structural-provisions#B1V1","x":"(1) This Verification Method is applicable to components with a resistance coefficient of variation of not more than 40%.\n(2) Where the calculated resistance coefficient of variation is less than 10%, then a minimum value of 10% must be used.\n(3) The resistance model for the component must be established by taking into account variability due to material properties, fabrication and construction processes, structural modelling and time dependent effects.\n(4) Annual action models must be determined for all reasonably expected actions and combinations of actions in accordance with Table B1V1a.\n(5) Compliance with B1P1(2) is verified for the design of a component where—\nthe calculated reliability index [formula] is not less than the applicable required values.\nthe reliability index [formula] is calculated in accordance with the equation: [formula] , where—\n[formula] ; and\n[formula] , where subject to (iii)—\n[formula] = means resistance; and\n[formula] = means action; and\n[formula] = coefficient of variation of the action; and\n[formula] = coefficient of variation of the resistance; and\nWhere the load action [formula] is due to the combination of multiple structural actions—\n[formula] ; and\nthe mean of the combined load action is calculated in accordance with the equation: [formula] , where [formula] is the mean of theith action [formula] ; and\nthe standard deviation of the combined load action is calculated in accordance with the equation: [formula] , where [formula] is the standard deviation of theith action [formula] ; and\nthe coefficient of the variation of the combined action [formula] is calculated in accordance with the equation [formula] .\nTable B1V1a Annual action models\nDesign action\nRatio of mean action to nominal\nCoefficient of variation of the action\nPermanent action\n1.05\n0.10\nAnnual maximum imposed action\n0.35\n0.45\nArbitrary-point-in-time imposed action\n0.25\n0.78\nWind (non-cyclonic regions, Importance Level 1)\n0.37\n0.47\nWind (non-cyclonic regions, Importance Level 2)\n0.31\n0.47\nWind (non-cyclonic regions, Importance Level 3)\n0.29\n0.47\nWind (non-cyclonic regions, Importance Level 4)\n0.27\n0.47\nWind (cyclonic regions, Importance Level 1)\n0.19\n0.76\nWind (cyclonic regions, Importance Level 2)\n0.16\n0.76\nWind (cyclonic regions, Importance Level 3)\n0.14\n0.76\nWind (cyclonic regions, Importance Level 4)\n0.13\n0.76\nEarthquake (Importance Level 1)\n0.28\n0.90\nEarthquake (Importance Level 2)\n0.15\n0.90\nEarthquake (Importance Level 3)\n0.12\n0.90\nEarthquake (Importance Level 4)\n0.084\n0.90\nSnow\n0.29\n0.57\nTable Notes\nActions not listed must be considered and derived on a case-by-case basis.\nNominal loads are based on AS/NZS 1170 series of standards.\nNotes\nB1V1 of NCC 2022 may apply instead of B1V1 of NCC 2025 until 1 year after the adoption date of NCC 2025.\nWhen determining appropriate combinations of actions to meet the requirements of B1V1(5)(b)(ii), consideration must be made for those given in AS/NZS 1170.\nB1V1 may be used for all materials and actions to determine compliance with B1P1(2).\nRequirements for values of 𝛽 can be found in Table B1P1a, Table B1P1b and Table B1P1c.","g":"/ncc/b1v1","a19":["BV1"]},{"c":"B1V2","t":"Structural robustness","p":"Part B1 Structural provisions","u":"/editions/ncc-2025/adopted/volume-one/b-structure/part-b1-structural-provisions#B1V2","x":"(1) Compliance with B1P1(1)(c) is verified for structural robustness if (2) and (3) are complied with.\n(2) The structure is assessed such that the building remains stable and the resulting collapse does not extend further than the immediately adjacent storeys upon the notional removal in isolation of—\nany supporting column; or\nany beam supporting one or more columns; or\nany segment of a load bearing wall of length equal to the height of the wall.\n(3) It is demonstrated that if a supporting structural component is relied upon to carry more than 25% of the total structure, a systematic risk assessment of the building is undertaken and critical high risk components are identified and designed to cope with the identified hazard or protective measures chosen to minimise the risk.","g":"/ncc/b1v2","a19":["BV2"]},{"c":"B1D1","t":"Deemed-to-Satisfy Provisions","p":"Part B1 Structural provisions","u":"/editions/ncc-2025/adopted/volume-one/b-structure/part-b1-structural-provisions#B1D1","x":"(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements B1P1 to B1P3 are satisfied by complying with B1D2 to B1D6.\n(2) Where a Performance Solution is proposed, the relevant Performance Requirements must be determined in accordance with A2G2(3) and A2G4(3) as applicable.","g":"/ncc/b1d1","a19":["B1.0"]},{"c":"B1D2","t":"Resistance to actions","p":"Part B1 Structural provisions","u":"/editions/ncc-2025/adopted/volume-one/b-structure/part-b1-structural-provisions#B1D2","x":"The resistance of a building or structure must be greater than the most critical action effect resulting from different combinations of actions, where—\nthe most critical action effect on a building or structure is determined in accordance with B1D3 and the general design procedures contained in AS/NZS 1170.0; and\ndesign for the actions in (a) accommodates expected 10-year deflection for structural substrates in Part F1; and\nthe resistance of a building or structure is determined in accordance with B1D4.","g":"/ncc/b1d2","a19":["B1.1"]},{"c":"Table B1D3a","t":"Importance Levels of buildings and structures","p":"Part B1 Structural provisions","u":"/editions/ncc-2025/adopted/volume-one/b-structure/part-b1-structural-provisions#_4c1dd6a6-8059-4f49-bc62-d12d250e962c","x":"Importance level | Building Types\n1 | Buildings or structures presenting a low degree of hazard to life and other property in the case of failure.\n2 | Buildings or structures not included in Importance Level 1, 3 and 4.\n3 | Buildings or structures that are designed to contain a large number of people.\n4 | Buildings or structures that are essential to post-disaster recovery or associated with hazardous facilities.","tb":"B1D3","g":"/ncc/table-b1d3a"},{"c":"Table B1D3b","t":"Design events for safety — Annual probability of exceedance","p":"Part B1 Structural provisions","u":"/editions/ncc-2025/adopted/volume-one/b-structure/part-b1-structural-provisions#_b7a95093-1d7c-469c-b13e-d37a5e650828","x":"Importance level | Non-cyclonic wind | Cyclonic wind (wind regions B2 and C) | Cyclonic wind (wind region D) | Snow | Earthquake\n1 | 1:100 | 1:200 | 1:250 | 1:100 | 1:250\n2 | 1:500 | 1:500 | 1:1000 | 1:150 | 1:500\n3 | 1:1000 | 1:1000 | 1:2000 | 1:200 | 1:1000\n4 | 1:2000 | 1:2000 | 1:5000 | 1:250 | 1:1500","tb":"B1D3","g":"/ncc/table-b1d3b"},{"c":"B1D3","t":"Determination of individual actions","p":"Part B1 Structural provisions","u":"/editions/ncc-2025/adopted/volume-one/b-structure/part-b1-structural-provisions#B1D3","x":"The magnitude of individual actions must be determined in accordance with the following:\nPermanent actions:\nthe design or known dimensions of the building or structure; and\nthe unit weight of the construction; and\nAS/NZS 1170.1; and\nfor a Class 7b building, a notional additional permanent roof load of not less than 0.15 kPa to support the addition of solar photovoltaic panels.\nImposed actions:\nthe known loads that will be imposed during the occupation or use of the building or structure; and\nconstruction activity actions; and\nAS/NZS 1170.1.\nWind, snow and ice and earthquake actions:\nthe applicable annual probability of design event for safety, determined by—\nassigning the building or structure an Importance Level in accordance with Table B1D3a; and\ndetermining the corresponding annual probability of exceedance in accordance with Table B1D3b; and\nAS/NZS 1170.2; and\nAS/NZS 1170.3 as appropriate; and\nAS 1170.4 as appropriate; and\nin cyclonic areas, metal roof cladding, its connections and immediate supporting members must comply with Specification 4; and\nfor the purposes of (v), cyclonic areas are those determined as being located in wind regions B2, C and D in accordance with AS/NZS 1170.2.\nActions not covered in (a), (b) and (c) above:\nthe nature of the action; and\nthe nature of the building or structure; and\nthe Importance Level of the building or structure determined in accordance with Table B1D3a; and\nAS/NZS 1170.1.\nFor the purposes of (d) the actions include but are not limited to—\nliquid pressure action; and\nground water action; and\nrainwater action (including ponding action); and\nearth pressure action; and\ndifferential movement; and\ntime dependent effects (including creep and shrinkage); and\nthermal effects; and\nground movement caused by—\nswelling, shrinkage or freezing of the subsoil; and\nlandslip or subsidence; and\nsiteworks associated with the building or structure; and\nconstruction activity actions.\nTable B1D3a Importance Levels of buildings and structures\nImportance level\nBuilding Types\n1\nBuildings or structures presenting a low degree of hazard to life and other property in the case of failure.\n2\nBuildings or structures not included in Importance Level 1, 3 and 4.\n3\nBuildings or structures that are designed to contain a large number of people.\n4\nBuildings or structures that are essential to post-disaster recovery or associated with hazardous facilities.\nTable B1D3b Design events for safety — Annual probability of exceedance\nImportance level\nNon-cyclonic wind\nCyclonic wind (wind regions B2 and C)\nCyclonic wind (wind region D)\nSnow\nEarthquake\n1\n1:100\n1:200\n1:250\n1:100\n1:250\n2\n1:500\n1:500\n1:1000\n1:150\n1:500\n3\n1:1000\n1:1000\n1:2000\n1:200\n1:1000\n4\n1:2000\n1:2000\n1:5000\n1:250\n1:1500\nExemptions\nB1D3(a)(iv) does not apply to a Class 7b building—\nwhere 100% of the roof area is shaded for more than 70% of daylight hours; or\nwith a roof area of not more than 55m2; or\nwhere more than 50% of the roof area is used as a terrace, carpark, roof garden, roof light or the like.","g":"/ncc/b1d3","a19":["B1.2"]},{"c":"Table B1D4","t":"Material and minimum thickness of glazing and polycarbonate sheet","p":"Part B1 Structural provisions","u":"/editions/ncc-2025/adopted/volume-one/b-structure/part-b1-structural-provisions#_815b1b3a-bc04-48f7-9f86-add5dfa48609","x":"Application | Lift shaft vision panels more than 65 000 mm2, door panels, and lift shafts | Lift shaft vision panels less than or equal to 65 000 mm2\nLaminated glass | 10 mm (0.76 mm interlayer) | 6 mm (0.76 mm interlayer)\nToughened/ laminated glass | 10 mm (0.76 mm interlayer) | 6 mm (0.76 mm interlayer)\nAnnealed glass with security polyester film coating | 10 mm | 6 mm\nSafety wire glass | Not applicable | Subject to fire test\nPolycarbonate sheet | 13 mm | 6 mm","tb":"B1D4","g":"/ncc/table-b1d4"},{"c":"B1D4","t":"Determination of structural resistance of materials and forms of construction","p":"Part B1 Structural provisions","u":"/editions/ncc-2025/adopted/volume-one/b-structure/part-b1-structural-provisions#B1D4","x":"The structural resistance of materials and forms of construction must be determined in accordance with the following, as appropriate:\nMasonry (including masonry-veneer, unreinforced masonry and reinforced masonry): AS 3700, except—\n‘(for piers—isolated or engaged)’ is removed from Clause 8.5.1(d); and\nwhere Clause 8.5.1 requires design as for unreinforced masonry in accordance with Section 7, the member must also be designed as unreinforced masonry in accordance with Tables 10.3 and 4.1(a)(i)(C) of AS 3700.\nConcrete:\nConcrete construction (including reinforced and prestressed concrete): AS 3600.\nAutoclaved aerated concrete: AS 5146.1 and AS 5146.3.\nPost-installed and cast-in fastenings: AS 5216.\nSteel construction:\nSteel structures: AS 4100.\nCold-formed steel structures: AS/NZS 4600.\nResidential and low-rise steel framing: NASH Standard – Residential and Low-Rise Steel Framing Part 1 or Part 2.\nComposite steel and concrete: AS/NZS 2327.\nAluminium construction: AS/NZS 1664.1 or AS/NZS 1664.2.\nTimber construction:\nDesign of timber structures: AS 1720.1.\nTimber structures: AS 1684.2, AS 1684.3 or AS 1684.4.\nNailplated timber roof trusses: AS 1720.5.\nPiling: AS 2159.\nGlazed assemblies:\nThe following glazed assemblies in an external wall must comply with AS 2047:\nWindows excluding those listed in (ii).\nSliding and swinging glazed doors with a frame, including french and bi-fold doors with a frame.\nAdjustable louvres.\nShopfronts.\nWindow walls with one piece framing.\nAll glazed assemblies not covered by (i) and the following glazed assemblies must comply with AS 1288:\nAll glazed assemblies not in an external wall.\nRevolving doors.\nFixed louvres.\nSkylights, roof lights and windows in other than the vertical plane.\nSliding and swinging doors without a frame.\nWindows constructed on site and architectural one-off windows, which are not design tested in accordance with AS 2047.\nSecond-hand windows, re-used windows and recycled windows.\nHeritage windows.\nGlazing used in balustrades and sloping overhead glazing.\nTermite Risk Management: Where a primary building element is subject to attack by subterranean termites: AS 3660.1, and—\nfor the purposes of this provision, a primary building element consisting entirely of, or a combination of, any of the following materials is considered not subject to termite attack:\nSteel, aluminium or other metals.\nConcrete.\nMasonry.\nFibre-reinforced cement.\nTimber — naturally termite resistant in accordance with Appendix C of AS 3660.1.\nTimber — preservative treated in accordance with Appendix D of AS 3660.1; and\na durable notice must be permanently fixed to the building in a prominent location, such as a meter box or the like, indicating—\nthe termite management system used; and\nthe date of installation of the system; and\nwhere a chemical is used, its life expectancy as listed on the appropriate authority’s pesticides register label; and\nthe installer’s or manufacturer’s recommendations for the scope and frequency of future inspections for termite activity.\nRoof construction (except in cyclonic areas):\nTerracotta, fibre-cement and timber slates and shingles: AS 4597.\nRoof tiling: AS 2050.\nCellulose cement corrugated sheets: AS/NZS 2908.1 with safety mesh installed in accordance with AS 1562.3 clause 2.4.3.2 except for sub-clause (c)(vii) for plastic sheeting.\nMetal roofing: AS 1562.1.\nRoof construction (cyclonic areas) — metal roofing: AS 1562.1 and Specification 4.\nParticleboard structural flooring: AS 1860.2.\nGarage doors and other large access doors in openings not more than 3 m in height in external walls of buildings determined as being located in wind region B2, C or D in accordance with AS/NZS 1170.2: AS/NZS 4505.\nLift shafts which are not required to have an FRL, must—\nexcept as required by (ii), be completely enclosed with non-perforated material between the bottom of the pit and the ceiling of the lift shaft, other than—\nat landing doors, emergency doors and pit access doors; and\nlow-rise, low-speed constant pressure lifts; and\nin atrium and observation areas, be protected with non-perforated material not less than 2.5 m in height—\nabove any places on which a person can stand, which are within 800 mm horizontal reach of any vertical moving lift component including ropes and counterweights; and\nat the lowest level of the atrium area that the lift serves, on all sides except the door opening, for not less than 2.5 m in height, by enclosure with non-perforated material; and\nbe of non-brittle material; and\nwhere glazing is used—\ncomply with Table B1D4; or\nnot fail the deflection criteria required by S6C11(c)(iii).\nTable B1D4 Material and minimum thickness of glazing and polycarbonate sheet\nApplication\nLift shaft vision panels more than 65 000 mm2, door panels, and lift shafts\nLift shaft vision panels less than or equal to 65 000 mm2\nLaminated glass\n10 mm (0.76 mm interlayer)\n6 mm (0.76 mm interlayer)\nToughened/ laminated glass\n10 mm (0.76 mm interlayer)\n6 mm (0.76 mm interlayer)\nAnnealed glass with security polyester film coating\n10 mm\n6 mm\nSafety wire glass\nNot applicable\nSubject to fire test\nPolycarbonate sheet\n13 mm\n6 mm","g":"/ncc/b1d4","a19":["B1.4","NT B1.4(i)","QLD B1.4(f)(v)"]},{"c":"B1D5","t":"Structural software","p":"Part B1 Structural provisions","u":"/editions/ncc-2025/adopted/volume-one/b-structure/part-b1-structural-provisions#B1D5","x":"(1) Structural software used in computer aided design of a building or structure, that uses design criteria based on the Deemed-to-Satisfy Provisions of the BCA, including its referenced documents, for the design of steel or timber trussed roof and floor systems and framed building systems, must comply with the ABCB Protocol for Structural Software.\n(2) Structural software referred to in (1) can only be used for buildings within the following geometric limits:\nThe distance from ground level to the underside of eaves must not exceed 6 m.\nThe distance from ground level to the highest point of the roof, neglecting chimneys, must not exceed 8.5 m.\nThe building width including roofed verandahs, excluding eaves, must not exceed 16 m.\nThe building length must not exceed five times the building width.\nThe roof pitch must not exceed 35 degrees.\n(3) The requirements of (1) do not apply to design software for individual frame members such as electronic tables similar to those provided in—\nAS 1684; or\nNASH Standard Residential and Low-Rise Steel Framing Part 2.","g":"/ncc/b1d5","a19":["B1.5"]},{"c":"B1D6","t":"Construction of buildings in flood hazard areas","p":"Part B1 Structural provisions","u":"/editions/ncc-2025/adopted/volume-one/b-structure/part-b1-structural-provisions#B1D6","x":"(1) A building in a flood hazard area must comply with the ABCB Standard for Construction of Buildings in Flood Hazard Areas.\n(2) The requirements of (1) only apply to a Class 2 or 3 building, Class 9a health-care building, Class 9c building or a Class 4 part of a building.","g":"/ncc/b1d6","a19":["VIC B1.6","B1.6"]},{"c":"S10C1","t":"Scope","p":"Specification 10 Fire-protected timber","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/10-fire-protected-timber#S10C1","x":"This Specification contains requirements for fire-protected timber and procedures for determining the time at which the temperature at the interface between the protection system and the timber is exceeded.","g":"/ncc/s10c1","a19":["Spec C1.13a: 1"]},{"c":"S10C2","t":"General requirements","p":"Specification 10 Fire-protected timber","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/10-fire-protected-timber#S10C2","x":"(1) Fire-protected timber must—\nutilise a non-combustible fire-protective covering fixed in accordance with the system requirements to achieve an FRL not less than that required for the building element; and\nhave a non-combustible fire-protective covering fixed in accordance with system requirements—\nto achieve a resistance to the incipient spread of fire of not less than 45 minutes when tested in accordance with—\nfor horizontal elements — Section 4 of AS 1530.4; and\nfor other elements — the relevant test procedures from Section 4 of AS 1530.4 applied to the element lining; or\nwhich consists of not less than 2 layers of 13 mm thick, fire-protective grade plasterboard.\n(2) For the purposes of (1), the non-combustible fire-protective covering provided under (1)(b) may form all or part of the non-combustible fire-protective covering provided under (1)(a).","g":"/ncc/s10c2","a19":["Spec C1.13a: 2.1"]},{"c":"Table S10C3","t":"Interface temperature and minimum fire protective grade plasterboard thickness","p":"Specification 10 Fire-protected timber","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/10-fire-protected-timber#_51e43184-1a58-4f7b-ab3c-919040fc8e40","x":"Application | Time – without timber interface exceeding 300°C (mins) | Minimum thickness of fire-grade plasterboard (mm)\nInside a fire-isolated stairway or lift shaft | 20 | 13\nExternal walls within 1 m of an allotment boundary or 2 m of a building on the same allotment | 45 | 2 x 13\nAll other applications | 30 | 16","tb":"S10C3","g":"/ncc/table-s10c3"},{"c":"S10C3","t":"Massive timber","p":"Specification 10 Fire-protected timber","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/10-fire-protected-timber#S10C3","x":"(1) Fire-protected timber, where the timber is massive timber, need not comply with S10C2 if the fire-protected timber —\nutilises a non-combustible fire-protective covering fixed in accordance with system requirements to achieve an FRL not less than that required for the building element; and\nhas a non-combustible fire-protective covering fixed in accordance with system requirements—\nso as the temperature at the interface between the protection system and the timber does not exceed 300°C during a fire resistance test performed in accordance with S10C4, S10C5 and S10C6 for the application and periods listed in Table S10C3; or\nnot less than that specified by Table S10C3; and\nhas any cavity filled with non-combustible insulation, or no cavity, between—\nthe surface of the timber and the fire-protective covering; or\ntimber elements within the fire-protective covering.\n(2) For the purposes of (1), the non-combustible fire-protective covering provided under (1)(b) may form all or part of the non-combustible fire-protective covering provided under (1)(a).\nTable S10C3 Interface temperature and minimum fire protective grade plasterboard thickness\nApplication\nTime – without timber interface exceeding 300°C (mins)\nMinimum thickness of fire-grade plasterboard (mm)\nInside a fire-isolated stairway or lift shaft\n20\n13\nExternal walls within 1 m of an allotment boundary or 2 m of a building on the same allotment\n45\n2 x 13\nAll other applications\n30\n16","g":"/ncc/s10c3","a19":["Spec C1.13a: 2.2"]},{"c":"S10C4","t":"Form of test","p":"Specification 10 Fire-protected timber","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/10-fire-protected-timber#S10C4","x":"(1) Tests must be carried out in accordance with the Standard Fire Test, or an equivalent or more severe test, on the timber element with the proposed non-combustible coverings fixed in a representative manner, with the time the timber interface temperatures exceeded 300°C confirmed in a report from an Accredited Testing Laboratory.\n(2) If a fire protection system incorporates joints, the test specimens must incorporate representative joints.\n(3) Interface temperatures must be measured over the following features by a minimum of two thermocouples:\nAt joint positions in the protection systems.\nAt least 200 mm from any joint.\nAt service penetrations.\nAt any other locations where, in the opinion of the Accredited Testing Laboratory, the interface temperature may be higher than the above positions.\n(4) The temperatures must be measured in accordance with Appendix C1 and Section 2 of AS 1530.4 as appropriate.","g":"/ncc/s10c4","a19":["Spec C1.13a: 3.1"]},{"c":"S10C5","t":"Smaller specimen permitted","p":"Specification 10 Fire-protected timber","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/10-fire-protected-timber#S10C5","x":"An Accredited Testing Laboratory may carry out the test specified in S10C4 at pilot scale provided—\na specimen (which must be not less than 1000 mm x 1000 mm) adequately represents the proposed construction in the building; and\nthe fire resistance of the specimen has already been determined in a full scale test performed in accordance with AS 1530.4 to demonstrate adequate retention of the fire protection system in conjunction with the timber elements being protected; and\nthe results of the test do not apply to construction larger than limits defined by the Accredited Testing Laboratory conducting the pilot examination.","g":"/ncc/s10c5","a19":["Spec C1.13a: 3.2"]},{"c":"S10C6","t":"Acceptance criteria","p":"Specification 10 Fire-protected timber","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/10-fire-protected-timber#S10C6","x":"The time the timber interface temperature exceeds 300°C must be taken as the minimum time any of the thermocouples specified in S10C4 exceeded 300°C.","g":"/ncc/s10c6","a19":["Spec C1.13a: 3.3"]},{"c":"S11C1","t":"Scope","p":"Specification 11 Smoke-proof walls in health-care and residential care buildings","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/11-smoke-proof-walls-health-care-and-residential-care-buildings#S11C1","x":"(1) This Specification sets out requirements for the construction of smoke-proof walls in Class 9a health-care buildings and Class 9c buildings.\n(2) Smoke proof walls required to have an FRL are to be in accordance with A5G5.","g":"/ncc/s11c1","a19":["Spec C2.5: 1"]},{"c":"S11C2","t":"Class 9a health-care buildings","p":"Specification 11 Smoke-proof walls in health-care and residential care buildings","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/11-smoke-proof-walls-health-care-and-residential-care-buildings#S11C2","x":"Smoke-proof walls required by C3D6 in Class 9a health-care buildings must comply with the following:\nBe lined on both sides.\nBe non-combustible and extend to the underside of—\nthe floor above; or\na non-combustible roof covering; or\na ceiling having a resistance to the incipient spread of fire to the space above itself of not less than 60 minutes.\nIf plasterboard is used as the lining on a wall, it must be minimum of 13 mm thick plasterboard.\nNot incorporate any glazed areas unless the glass is safety glass as defined in AS 1288.\nOnly have doorways which are fitted with smoke doors complying with Specification 12.\nHave all openings around penetrations and the junctions of the smoke-proof wall and the remainder of the building stopped with non-combustible material to prevent the free passage of smoke.\nIncorporate smoke dampers complying with AS 1668.1 where air-handling ducts penetrate the wall unless the duct forms part of a smoke hazard management system required to continue air movement through the duct during a fire.","g":"/ncc/s11c2","a19":["Spec C2.5: 2"]},{"c":"S11C3","t":"Class 9c buildings","p":"Specification 11 Smoke-proof walls in health-care and residential care buildings","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/11-smoke-proof-walls-health-care-and-residential-care-buildings#S11C3","x":"Smoke-proof walls required by C3D6 in Class 9c buildings must comply with the following:\nThe wall may be lined on one side only.\nLinings on the wall must be non-combustible and extend to the underside of—\nthe floor above; or\na non-combustible roof covering; or\na flush plasterboard ceiling lined with 13 mm standard grade plasterboard or a fire-protective covering, with all penetrations sealed against the free passage of smoke.\nIf plasterboard is used in the lining on a wall, it must be a minimum of 13 mm standard grade plasterboard.\nNot incorporate any glazed areas unless the glass is safety glass as defined in AS 1288.\nOnly have doorways which are fitted with smoke doors complying with Specification 12.\nHave all openings around penetrations and the junctions of the smoke-proof wall and the remainder of the building stopped with non-combustible material to prevent the free passage of smoke.\nIncorporate smoke dampers complying with AS 1668.1 where air-handling ducts penetrate the wall unless the duct forms part of a smoke hazard management system required to continue air movement through the duct during a fire.","g":"/ncc/s11c3","a19":["Spec C2.5: 3"]},{"c":"S11C4","t":"Doorways in smoke-proof walls","p":"Specification 11 Smoke-proof walls in health-care and residential care buildings","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/11-smoke-proof-walls-health-care-and-residential-care-buildings#S11C4","x":"A door required by C3D6 or this Specification to be smoke-proof or have an FRL must provide a smoke reservoir by not extending within 400 mm of the underside of—\na roof covering; or\nthe floor above; or\nan imperforate false ceiling that will prevent the free passage of smoke.","g":"/ncc/s11c4","a19":["Spec C2.5: 4"]},{"c":"S12C1","t":"Scope","p":"Specification 12 Fire doors, smoke doors, fire windows and shutters","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/12-fire-doors-smoke-doors-fire-windows-and-shutters#S12C1","x":"This Specification sets out requirements for the construction of fire doors, smoke doors, fire windows and fire shutters.","g":"/ncc/s12c1","a19":["Spec C3.4: 1"]},{"c":"S12C2","t":"Fire doors","p":"Specification 12 Fire doors, smoke doors, fire windows and shutters","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/12-fire-doors-smoke-doors-fire-windows-and-shutters#S12C2","x":"A required fire door must—\ncomply with AS 1905.1; and\nnot fail by radiation through any glazed part during the period specified for integrity in the required FRL.","g":"/ncc/s12c2","a19":["Spec C3.4: 2"]},{"c":"S12C3","t":"General requirements for smoke doors","p":"Specification 12 Fire doors, smoke doors, fire windows and shutters","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/12-fire-doors-smoke-doors-fire-windows-and-shutters#S12C3","x":"Smoke doors must be constructed so that smoke will not pass from one side of the doorway to the other and, if they are glazed, there is minimal danger of a person being injured by accidentally walking into them.","g":"/ncc/s12c3","a19":["Spec C3.4: 3.1"]},{"c":"S12C4","t":"Construction Deemed-to-Satisfy for smoke doors","p":"Specification 12 Fire doors, smoke doors, fire windows and shutters","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/12-fire-doors-smoke-doors-fire-windows-and-shutters#S12C4","x":"A smoke door of one or two leaves satisfies S12C3 if it is constructed as follows:\nThe leaves are side-hung to swing—\nin the direction of egress; or\nin both directions.\nThe leaves are solid-core and at least 35 mm thick, or are capable of resisting smoke at 200°C for 30 minutes.\nThe leaves are fitted with smoke seals.\nThe leaves—\nare normally in the closed position; or\noperate such that—\nthey are closed automatically with the automatic closing operation initiated by smoke detectors, installed in accordance with the relevant provisions of AS 1670.1, located on each side of the doorway not more than 1.5 m horizontal distance from the doorway; and\nin the event of power failure to the door, they will fail-safe in the closed position.\nThe leaves return to the fully closed position after each manual opening.\nAny glazing incorporated in the door complies with AS 1288.\nIf a glazed panel is capable of being mistaken for an unobstructed exit, the presence of the glass must be identified by an opaque mid-height band, mid-rail, crash-bar or other opaque construction.","g":"/ncc/s12c4","a19":["Spec C3.4: 3.2"]},{"c":"S12C5","t":"Fire shutters","p":"Specification 12 Fire doors, smoke doors, fire windows and shutters","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/12-fire-doors-smoke-doors-fire-windows-and-shutters#S12C5","x":"A required fire shutter must—\nbe a shutter that—\nis identical with a tested prototype that has achieved the required FRL; and\nis installed in the same manner and in an opening that is not larger than the tested prototype; and\ndid not have a rise in average temperature on the side remote from the furnace of more than 140 K during the first 30 minutes of the test; or\nbe a steel shutter complying with AS 1905.2 if a metallic fire shutter is not prohibited by C4D6.","g":"/ncc/s12c5","a19":["Spec C3.4: 4"]},{"c":"S12C6","t":"Fire windows","p":"Specification 12 Fire doors, smoke doors, fire windows and shutters","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/12-fire-doors-smoke-doors-fire-windows-and-shutters#S12C6","x":"A required fire window must be—\nidentical in construction with a prototype that has achieved the required FRL; and\ninstalled in the same manner and in an opening that is not larger than the tested prototype.","g":"/ncc/s12c6","a19":["Spec C3.4: 5"]},{"c":"S13C1","t":"Scope","p":"Specification 13 Penetration of walls, floors and ceilings by services","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/13-penetration-walls-floors-and-ceilings-services#S13C1","x":"This Specification prescribes materials and methods of installation for services that penetrate walls, floors and ceilings required to have an FRL.","g":"/ncc/s13c1","a19":["Spec C3.15: 1"]},{"c":"S13C2","t":"Application","p":"Specification 13 Penetration of walls, floors and ceilings by services","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/13-penetration-walls-floors-and-ceilings-services#S13C2","x":"(1) This Specification applies to installations permitted under the Deemed-to-Satisfy Provisions of the NCC as alternatives to systems that have been demonstrated by test to fulfil the requirements of C4D15(2)(a).\n(2) This Specification does not apply to installations in ceilings required to have a resistance to the incipient spread of fire nor to the installation of piping that contains or is intended to contain a flammable liquid or gas.","g":"/ncc/s13c2","a19":["Spec C3.15: 2"]},{"c":"S13C3","t":"Metal pipe systems","p":"Specification 13 Penetration of walls, floors and ceilings by services","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/13-penetration-walls-floors-and-ceilings-services#S13C3","x":"(1) A pipe system comprised entirely of metal (excluding pipe seals or the like) that is not normally filled with liquid must not be located within 100 mm, for a distance of 2 m from the penetration, of any combustible building element or a position where combustible material may be located, and must be constructed of—\ncopper alloy or stainless steel with a wall thickness of at least 1 mm; or\ncast iron or steel (other than stainless steel) with a wall thickness of at least 2 mm.\n(2) An opening for a pipe system comprised entirely of metal (excluding pipe seals or the like) must—\nbe neatly formed, cut or drilled; and\nbe no closer than 200 mm to any other service penetration; and\naccommodate only one pipe.\n(3) A pipe system comprised entirely of metal (excluding pipe seals or the like) must be wrapped but must not be lagged or enclosed in thermal insulation over the length of its penetration of a wall, floor or ceiling unless the lagging or thermal insulation fulfils the requirements of S13C7.\n(4) The gap between a metal pipe and the wall, floor or ceiling it penetrates must be fire-stopped in accordance with S13C7.","g":"/ncc/s13c3","a19":["Spec C3.15: 3"]},{"c":"S13C4","t":"Pipes penetrating sanitary compartments","p":"Specification 13 Penetration of walls, floors and ceilings by services","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/13-penetration-walls-floors-and-ceilings-services#S13C4","x":"If a pipe of metal or UPVC penetrates the floor of a sanitary compartment in accordance with C4D15(2)(c)(ii) —\nthe opening must be neatly formed and no larger than is necessary to accommodate the pipe or fitting; and\nthe gap between pipe and floor must be fire-stopped in accordance with S13C7.","g":"/ncc/s13c4","a19":["Spec C3.15: 4"]},{"c":"S13C5","t":"Wires and cables","p":"Specification 13 Penetration of walls, floors and ceilings by services","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/13-penetration-walls-floors-and-ceilings-services#S13C5","x":"If a wire or cable or cluster of wires or cables penetrates a floor, wall or ceiling—\nthe opening must be neatly formed, cut or drilled and no closer than 50 mm to any other service; and\nthe opening must be no larger in cross-sectional area than—\n2000 mm2 if only a single cable is accommodated and the gap between cable and wall, floor or ceiling is no wider than 15 mm; or\n500 mm2 in any other case; and\nthe gap between the service and the wall, floor or ceiling must be fire-stopped in accordance with S13C7.","g":"/ncc/s13c5","a19":["Spec C3.15: 5"]},{"c":"S13C6","t":"Electrical switches and outlets","p":"Specification 13 Penetration of walls, floors and ceilings by services","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/13-penetration-walls-floors-and-ceilings-services#S13C6","x":"If an electrical switch, outlet, socket or the like is accommodated in an opening or recess in a wall, floor or ceiling—\nthe opening or recess must not—\nbe located opposite any point within 300 mm horizontally or 600 mm vertically of any opening or recess on the opposite side of the wall; or\nextend beyond half the thickness of the wall; and\nthe gap between the service and the wall, floor or ceiling must be fire-stopped in accordance with S13C7.","g":"/ncc/s13c6","a19":["Spec C3.15: 6"]},{"c":"S13C7","t":"Fire-stopping","p":"Specification 13 Penetration of walls, floors and ceilings by services","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/13-penetration-walls-floors-and-ceilings-services#S13C7","x":"(1) Material: The material used for the fire-stopping of service penetrations must be concrete, high-temperature mineral fibre, high-temperature ceramic fibre or other material that does not flow at a temperature below 1120°C when tested in accordance with ISO 540, and must have—\ndemonstrated in a system tested in accordance with C4D15(2)(a) that it does not impair the fire-resisting performance of the building element in which it is installed; or\ndemonstrated in a test in accordance with (5) that it does not impair the fire-resisting performance of the test slab.\n(2) Installation: Fire-stopping material must be packed into the gap between the service and wall, floor or ceiling in a manner, and compressed to the same degree, as adopted for testing under (1)(a) or (b).\n(3) Hollow construction: If a pipe penetrates a hollow wall (such as a stud wall, a cavity wall or a wall of hollow blockwork) or a hollow floor/ceiling system, the cavity must be so framed and packed with fire-stopping material that is—\ninstalled in accordance with (2) to a thickness of 25 mm all round the service for the full length of the penetration; and\nrestrained, independently of the service, from moving or parting from the surfaces of the service and of the wall, floor or ceiling.\n(4) Recesses: If an electrical switch, socket, outlet or the like is accommodated in a recess in a hollow wall or hollow floor/ceiling system—\nthe cavity immediately behind the service must be framed and packed with fire-stopping material in accordance with (3); or\nthe back and sides of the service must be protected with refractory lining board identical with and to the same thickness as that in which the service is installed.\n(5) Test: The test to demonstrate compliance of a fire-stopping material with this Specification must be conducted as follows:\nThe test specimen must comprise a concrete slab not less than 1 m square and not more than 100 mm thick, and appropriately reinforced if necessary for structural adequacy during manufacture, transport and testing.\nThe slab must have a hole 50 mm in diameter through the centre and the hole must be packed with the fire-stopping material.\nThe slab must be conditioned in accordance with AS 1530.4.\nTwo thermocouples complying with AS 1530.4 must be attached to the upper surface of the packing each about 5 mm from its centre.\nThe slab must be tested on flat generally in accordance with Section 10 of AS 1530.4 and must achieve an FRL of 60/60/60 or as otherwise required.","g":"/ncc/s13c7","a19":["Spec C3.15: 7"]},{"c":"S5C1","t":"Scope","p":"Specification 5 Fire-resisting construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/5-fire-resisting-construction#S5C1","x":"This Specification contains requirements for the fire-resisting construction of building elements.","g":"/ncc/s5c1","a19":["Spec C1.1: 1"]},{"c":"S5C2","t":"Exposure to fire-source features","p":"Specification 5 Fire-resisting construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/5-fire-resisting-construction#S5C2","x":"(1) A part of a building element is exposed to a fire-source feature if any of the horizontal straight lines between that part and the fire-source feature, or vertical projection of the feature, is not obstructed by another part of the building that—\nhas an FRL of not less than 30/–/–; and\nis neither transparent nor translucent.\n(2) A part of a building element is not exposed to a fire-source feature if the fire-source feature is—\nan external wall of another building that stands on the allotment and the part concerned is more than 15 m above the highest part of that external wall; or\na side or rear boundary of the allotment and the part concerned is below the level of the finished ground at every relevant part of the boundary concerned.\n(3) If various distances apply for different parts of a building element—\nthe entire element must have the FRL applicable to that part having the least distance between itself and the relevant fire-source feature; or\neach part of the element must have the FRL applicable according to its individual distance from the relevant fire-source feature.\n(4) The requirements of (3) do not override or permit any exemption from S5C3.","g":"/ncc/s5c2","a19":["Spec C1.1: 2.1"]},{"c":"S5C3","t":"Fire protection for a support of another part","p":"Specification 5 Fire-resisting construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/5-fire-resisting-construction#S5C3","x":"(1) Where a part of a building required to have an FRL depends upon direct vertical or lateral support from another part to maintain its FRL, that supporting part, subject to (2), must—\nhave an FRL not less than that required by other provisions of this Specification; and\nif located within the same fire compartment as the part it supports have an FRL in respect of structural adequacy the greater of that required —\nfor the supporting part itself; and\nfor the part it supports; and\nbe non-combustible —\nif required by other provisions of this Specification; or\nif the part it supports is required to be non-combustible.\n(2) The following building elements need not comply with (1)(b) and (1)(c)(ii):\nAn element providing lateral support to an external wall complying with S5C24(1)(b) or C2D12.\nAn element providing support within a carpark and complying with S5C19, S5C22 or S5C25.\nA roof providing lateral support in a building—\nof Type A construction if it complies with S5C15(a), (b) or (d); and\nof Type B and C construction.\nA column providing lateral support to a wall where the column complies with S5C6(1) and (2).\nAn element providing lateral support to a fire wall or fire-resisting wall, provided the wall is supported on both sides and failure of the element on one side does not affect the fire performance of the wall.","g":"/ncc/s5c3","a19":["Spec C1.1: 2.2"]},{"c":"S5C4","t":"Lintels","p":"Specification 5 Fire-resisting construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/5-fire-resisting-construction#S5C4","x":"(1) A lintel must have the FRL required for the part of the building in which it is situated.\n(2) A lintel need not comply with (1) if it does not contribute to the support of a fire door, fire window or fire shutter, and—\nit spans an opening in—\na wall of a building containing only one storey; or\na non-load bearing wall of a Class 2 or 3 building; or\nit spans an opening in masonry which is not more than 150 mm thick and—\nnot more than 3 m wide if the masonry is non-load bearing; or\nnot more than 1.8 m wide if the masonry is load bearing and part of a solid wall or one of the leaves of a cavity wall.","g":"/ncc/s5c4","a19":["Spec C1.1: 2.3"]},{"c":"S5C5","t":"Method of attachment not to reduce the fire-resistance of building elements","p":"Specification 5 Fire-resisting construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/5-fire-resisting-construction#S5C5","x":"The method of attaching or installing a finish, lining, ancillary element or service installation to the building element must not reduce the fire-resistance of that element to below that required.","g":"/ncc/s5c5","a19":["Spec C1.1: 2.4"]},{"c":"S5C6","t":"General concessions","p":"Specification 5 Fire-resisting construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/5-fire-resisting-construction#S5C6","x":"(1) Steel columns — A steel column, other than one in a fire wall or common wall, need not have an FRL in a building that contains—\nonly 1 storey; or\n2 storeys in some of its parts and 1 storey only in its remaining parts if the sum of the floor areas of the upper storeys of its 2 storey parts does not exceed the lesser of—\n1/8 of the sum of the floor areas of the 1 storey parts; or\nin the case of a building to which one of the maximum floor areas specified in Table C3D3 is applicable — 1/10 of that area; or\nin the case of a building to which two or more of the maximum floor area specified in Table C3D3 is applicable — 1/10 of the lesser of those areas.\n(2) Timber columns — A timber column may be used in a single storey building if—\nin a fire wall or common wall the column has an FRL not less than that listed in Table S5C11d, S5C21d or S5C24c as appropriate; and\nin any other case where the column is required to have an FRL in accordance with Table S5C11a, S5C11c, S5C11g, S5C21a, S5C21c, S5C21g, S5C24a or S5C24b, it has an FRL of not less than 30/–/–.\n(3) Structures on roofs — A non-combustible structure situated on a roof need not comply with the other provisions of this Specification if it only contains—\nlift motor equipment; or\none or more of the following:\nHot water or other water tanks.\nVentilating ductwork, ventilating fans and their motors.\nAir-conditioning chillers.\nWindow cleaning equipment.\nOther service units that are non-combustible and do not contain flammable or combustible liquids or gases.\n(4) Curtain walls and panel walls — A requirement for an external wall to have an FRL does not apply to a curtain wall or panel wall which is of non-combustible construction and fully protected by automatic external wall-wetting sprinklers.\n(5) Balconies and verandahs — A balcony, verandah or the like and any incorporated supporting part, which is attached to or forms part of a building, need not comply with Table S5C11c, S5C11g, S5C21c, S5C21g, S5C24b or S5C24e if—\nit does not form part of the only path of travel to a required exit from the building; and\nin Type A construction—\nit is situated not more than 2 storeys above the lowest storey providing direct egress to a road or open space; and\nany supporting columns are of non-combustible construction.","g":"/ncc/s5c6","a19":["Spec C1.1: 2.5"]},{"c":"Table S5C7","t":"Increased FRLs — Construction surrounding mezzanines","p":"Specification 5 Fire-resisting construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/5-fire-resisting-construction#_9f201a0e-8218-4051-a198-49f0e6e8b368","x":"Level otherwise required  for any FRL criterion (mins) | Increase in level to not less than (mins)\n30 | 60\n60 | 90\n90 | 120\n120 | 180\n180 | 240\nTable Notes\nThe increase in level applies to each FRL criterion (structural adequacy, integrity or insulation) relevant to the building element concerned.","tb":"S5C7","g":"/ncc/table-s5c7"},{"c":"S5C7","t":"Mezzanine floors: Concession","p":"Specification 5 Fire-resisting construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/5-fire-resisting-construction#S5C7","x":"(1) This Clause does not apply to a Class 9b building that is a spectator stand or audience viewing area accommodating more than 100 persons as calculated according to D2D18.\n(2) A mezzanine and its supports need not have an FRL or be non-combustible provided—\nthe total floor area of all the mezzanines in the same room does not exceed 1/3 of the floor area of the room or 200 m2, whichever is the lesser; and\nthe FRL of each wall and column that supports any other part of the building within 6 m of the mezzanine is increased by the amount listed in Table S5C7.\nTable S5C7 Increased FRLs — Construction surrounding mezzanines\nLevel otherwise required  for any FRL criterion (mins)\nIncrease in level to not less than (mins)\n30\n60\n60\n90\n90\n120\n120\n180\n180\n240\nTable Notes\nThe increase in level applies to each FRL criterion (structural adequacy, integrity or insulation) relevant to the building element concerned.","g":"/ncc/s5c7","a19":["Spec C1.1: 2.6"]},{"c":"S5C8","t":"Enclosure of shafts","p":"Specification 5 Fire-resisting construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/5-fire-resisting-construction#S5C8","x":"(1) Shafts required to have an FRL must be enclosed at the top and bottom by construction having an FRL not less than that required for the walls of a non-load bearing shaft in the same building.\n(2) The provisions of (1) need not apply to—\nthe top of a shaft extending beyond the roof covering, other than one enclosing a fire-isolated stairway or ramp; or\nthe bottom of a shaft if it is non-combustible and laid directly on the ground.","g":"/ncc/s5c8","a19":["Spec C1.1: 2.7"]},{"c":"S5C9","t":"Carparks and ancillary uses for Class 2 and 3 buildings","p":"Specification 5 Fire-resisting construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/5-fire-resisting-construction#S5C9","x":"(1) A Class 7 part of a building may be regarded as Class 2 for the purpose of determining the relevant fire-resisting requirements of this Specification where—\nthe entire building—\nconsists only of Class 2 and Class 7; and\ncontains not more than 4 storeys; and\nthe Class 7 part—\nis wholly within the same storey; and\nhas a purpose that is ancillary to the building, such as carparking; and\nis the only Class 7 part within the entire building.\n(2) A Class 7 part of a building may be regarded as Class 3 for the purpose of determining the relevant fire-resisting requirements of this Specification where—\nthe entire building—\nconsists only of Class 3 and Class 7; and\ncontains not more than 3 storeys; and\nthe Class 7 part—\nis wholly within the same storey; and\nhas a purpose that is ancillary to the building, such as carparking; and\nis the only Class 7 part within the entire building.\nApplications\nFor S5C9(2), reference to ‘Class 3’ may include Class 2 parts in conjunction with Class 3 parts.","g":"/ncc/s5c9","a19":["Spec C1.1: 2.8"]},{"c":"S5C10","t":"Residential care building: Concession","p":"Specification 5 Fire-resisting construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/5-fire-resisting-construction#S5C10","x":"(1) In a Class 3 building protected with a sprinkler system complying with Specification 17 and used as a residential care building, any FRL criterion prescribed in Tables S5C11a, S5C11d, S5C11e, S5C11f, S5C11g, S5C21a, S5C21d, S5C21e, S5C21f, S5C21g, S5C24a, S5C24c or S5C24d —\nfor any floor and any load bearing wall, may be reduced to 60, except any FRL criterion of 90 for an external wall must be maintained when tested from the outside; and\nfor any non-load bearing internal wall, need not apply if—\nit is lined on each side with standard grade plasterboard not less than 13 mm thick or similar non-combustible material; and\nit extends—\nto the underside of the floor next above; or\nto the underside of a ceiling lined with standard grade plasterboard not less than 13 mm thick or a material with at least an equivalent level of fire protection; or\nto the underside of a non-combustible roof covering; and\nany insulation installed in the cavity of the wall is non-combustible; and\nany construction joint, space or the like between the top of the wall and the floor, ceiling or roof is smoke sealed with intumescent putty or other suitable material.\n(2) The concession described at (1) does not apply to fire-protected timber building elements.","g":"/ncc/s5c10","a19":["Spec C1.1: 2.9"]},{"c":"Table S5C11a","t":"Type A construction: FRL of loadbearing parts of external walls","p":"Specification 5 Fire-resisting construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/5-fire-resisting-construction#_6b657ade-f733-49f4-bed3-f24310d69902","x":"Distance from a fire-source feature | FRL (in minutes): Structural adequacy / Integrity / Insulation\nClass 2, 3 or 4 part | Class 5, 7a or 9 | Class 6 | Class 7b or 8\nLess than 1.5 m | 90/90/90 | 120/120/120 | 180/180/180 | 240/240/240\n1.5 to less than 3 m | 90/60/60 | 120/90/90 | 180/180/120 | 240/240/180\n3 m or more | 90/60/30 | 120/60/30 | 180/120/90 | 240/180/90","tb":"S5C11","g":"/ncc/table-s5c11a"},{"c":"Table S5C11b","t":"Type A construction: FRL of non-loadbearing parts of external walls","p":"Specification 5 Fire-resisting construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/5-fire-resisting-construction#_3481b164-4ce2-43aa-805d-23b4ffdbf6fe","x":"Distance from a fire-source feature | FRL (in minutes): Structural adequacy / Integrity / Insulation\nClass 2, 3 or 4 part | Class 5, 7a or 9 | Class 6 | Class 7b or 8\nLess than 1.5 m | –/90/90 | –/120/120 | –/180/180 | –/240/240\n1.5 to less than 3 m | –/60/60 | –/90/90 | –/180/120 | –/240/180\n3 m or more | –/–/– | –/–/– | –/–/– | –/–/–","tb":"S5C11","g":"/ncc/table-s5c11b"},{"c":"Table S5C11c","t":"Type A construction: FRL of external columns not incorporated in an external wall","p":"Specification 5 Fire-resisting construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/5-fire-resisting-construction#_62af2ea2-0b29-45de-b599-c07de6e68b37","x":"Column type | FRL (in minutes): Structural adequacy / Integrity / Insulation\nClass 2, 3 or 4 part | Class 5, 7a or 9 | Class 6 | Class 7b or 8\nLoad bearing | 90/–/– | 120/–/– | 180/–/– | 240/–/–\nNon-load bearing | –/–/– | –/–/– | –/–/– | –/–/–","tb":"S5C11","g":"/ncc/table-s5c11c"},{"c":"Table S5C11d","t":"Type A construction: FRL of common walls and fire walls","p":"Specification 5 Fire-resisting construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/5-fire-resisting-construction#_caa36997-3a3c-4468-9c0e-af6cbf20b2c1","x":"Wall type | FRL (in minutes): Structural adequacy / Integrity / Insulation\nClass 2, 3 or 4 part | Class 5, 7a or 9 | Class 6 | Class 7b or 8\nLoad bearing or non-load bearing | 90/90/90 | 120/120/120 | 180/180/180 | 240/240/240","tb":"S5C11","g":"/ncc/table-s5c11d"},{"c":"Table S5C11e","t":"Type A construction: FRL of loadbearing internal walls","p":"Specification 5 Fire-resisting construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/5-fire-resisting-construction#_5873ecd7-6bda-4041-8748-938d41a4ed99","x":"Location | FRL (in minutes): Structural adequacy / Integrity / Insulation\nClass 2, 3 or 4 part | Class 5, 7a or 9 | Class 6 | Class 7b or 8\nFire-resisting lift and stair shafts | 90/90/90 | 120/120/120 | 180/120/120 | 240/120/120\nBounding public corridors, public lobbies and the like | 90/90/90 | 120/–/– | 180/–/– | 240/–/–\nBetween or bounding sole-occupancy units | 90/90/90 | 120/–/– | 180/–/– | 240/–/–\nVentilating, pipe, garbage, and like shafts not used for the discharge of hot products of combustion | 90/90/90 | 120/90/90 | 180/120/120 | 240/120/120","tb":"S5C11","g":"/ncc/table-s5c11e"},{"c":"Table S5C11f","t":"Type A construction: FRL of non-loadbearing internal walls","p":"Specification 5 Fire-resisting construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/5-fire-resisting-construction#_07e7dda1-1428-4e17-b524-0d7d4fd10fa3","x":"Location | FRL (in minutes): Structural adequacy / Integrity / Insulation\nClass 2, 3 or 4 part | Class 5, 7a or 9 | Class 6 | Class 7b or 8\nFire-resisting lift and stair shafts | –/90/90 | –/120/120 | –120/120 | –/120/120\nBounding public corridors, public lobbies and the like | –/60/60 | –/–/– | –/–/– | –/–/–\nBetween or bounding sole-occupancy units | –/60/60 | –/–/– | –/–/– | –/–/–\nVentilating, pipe, garbage, and like shafts not used for the discharge of hot products of combustion | –/90/90 | –/90/90 | –/120/120 | –/120/120","tb":"S5C11","g":"/ncc/table-s5c11f"},{"c":"Table S5C11g","t":"Type A construction: FRL of other building elements not covered by Tables S5C11a to S5C11f","p":"Specification 5 Fire-resisting construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/5-fire-resisting-construction#_4dced6ad-b9b5-488a-bedc-5a9e626ea74a","x":"Building element | FRL (in minutes): Structural adequacy / Integrity / Insulation\nClass 2, 3 or 4 part | Class 5, 7a or 9 | Class 6 | Class 7b or 8\nOther load bearing internal walls, internal beams, trusses and columns | 90/–/– | 120/–/– | 180/–/– | 240/–/–\nFloors | 90/90/90 | 120/120/120 | 180/180/180 | 240/240/240\nRoofs | 90/60/30 | 120/60/30 | 180/60/30 | 240/90/60","tb":"S5C11","g":"/ncc/table-s5c11g"},{"c":"S5C11","t":"Type A fire-resisting construction — fire-resistance of building elements","p":"Specification 5 Fire-resisting construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/5-fire-resisting-construction#S5C11","x":"(1) In a building required to be of Type A construction—\neach building element listed in Tables S5C11a, S5C11b, S5C11c, S5C11d, S5C11e, S5C11f and S5C11g, and any beam or column incorporated in it, must have an FRL not less than that listed in those Tables for the particular class of building concerned; and\nany internal wall required to have an FRL with respect to integrity and insulation must extend to—\nthe underside of the floor next above; or\nthe underside of a roof complying with Table S5C11g; or\nif under S5C15 the roof is not required to comply with Table S5C11g, the underside of the non-combustible roof covering and, except for roof battens with dimensions of 75 mm x 50 mm or less or sarking-type material, must not be crossed by timber or other combustible building elements; or\na ceiling that is immediately below the roof and has a resistance to the incipient spread of fire to the roof space between the ceiling and the roof of not less than 60 minutes; and\na load bearing internal wall and a load bearing fire wall (including those that are part of a load bearing shaft) must be constructed from—\nconcrete; or\nmasonry; or\nsubject to (2), fire-protected timber; or\nsubject to (3), fire-protected steel; or\nany combination of (i) to (iv); and\nthe FRLs specified in Table S5C11c for an external column apply also to those parts of an internal column that face and are within 1.5 m of a window and are exposed through that window to a fire-source feature.\n(2) For the purposes of (1)(c)(iii), fire-protected timber may be used, provided that—\nthe building is—\na separate building; or\na part of a building—\nwhich only occupies part of a storey, and is separated from the remaining part by a fire wall; or\nwhich is located above or below a part not containing fire-protected timber and the floor between the adjoining parts is provided with an FRL not less than that prescribed for a fire wall for the lower storey; and\nthe building has an effective height of not more than 25 m; and\nthe building has a sprinkler system (other than a FPAA101D or FPAA101H system) throughout complying with Specification 17; and\nany insulation installed in the cavity of the timber building element required to have an FRL is non-combustible; and\ncavity barriers are provided in accordance with Specification 9.\n(3) For the purposes of (1)(c)(iv), fire-protected steel may be used in a Class 2 or 3 building or the uppermost storey of any other building classification, provided that—\nthe building is—\na separate building; or\na part of a building—\nwhich only occupies part of a storey, and is separate from the remaining part by a fire wall; or\nwhich is located above a part not containing fire-protected steel and the floor between adjoining parts is provided with an FRL, not less than that prescribed for a fire wall for the lower storey; and\nthe building has an effective height of not more than 25 m; and\nthe building has a sprinkler system (other than a FPAA101D or FPAA101H system) throughout complying with Specification 17; and\nany insulation installed in the cavity of walls required to have an FRL is non-combustible; and\nat each floor level, any cavity within a wall required to have an FRL that provides a vertically continuous gap to the level above is interrupted by a cavity barrier in the form of a steel member, steel sheet of 0.5 mm base metal thickness or greater, a 16 mm thick or greater fire-protective grade plasterboard or a 45 mm thick or greater mineral wool barrier.\n(4) For the purposes of Table S5C11a and Table S5C11b, external wall includes any column and other building element incorporated within it or other external building element.\nTable S5C11a Type A construction: FRL of loadbearing parts of external walls\nDistance from a fire-source feature\nFRL (in minutes): Structural adequacy / Integrity / Insulation\nClass 2, 3 or 4 part\nClass 5, 7a or 9\nClass 6\nClass 7b or 8\nLess than 1.5 m\n90/90/90\n120/120/120\n180/180/180\n240/240/240\n1.5 to less than 3 m\n90/60/60\n120/90/90\n180/180/120\n240/240/180\n3 m or more\n90/60/30\n120/60/30\n180/120/90\n240/180/90\nTable S5C11b Type A construction: FRL of non-loadbearing parts of external walls\nDistance from a fire-source feature\nFRL (in minutes): Structural adequacy / Integrity / Insulation\nClass 2, 3 or 4 part\nClass 5, 7a or 9\nClass 6\nClass 7b or 8\nLess than 1.5 m\n–/90/90\n–/120/120\n–/180/180\n–/240/240\n1.5 to less than 3 m\n–/60/60\n–/90/90\n–/180/120\n–/240/180\n3 m or more\n–/–/–\n–/–/–\n–/–/–\n–/–/–\nTable S5C11c Type A construction: FRL of external columns not incorporated in an external wall\nColumn type\nFRL (in minutes): Structural adequacy / Integrity / Insulation\nClass 2, 3 or 4 part\nClass 5, 7a or 9\nClass 6\nClass 7b or 8\nLoad bearing\n90/–/–\n120/–/–\n180/–/–\n240/–/–\nNon-load bearing\n–/–/–\n–/–/–\n–/–/–\n–/–/–\nTable S5C11d Type A construction: FRL of common walls and fire walls\nWall type\nFRL (in minutes): Structural adequacy / Integrity / Insulation\nClass 2, 3 or 4 part\nClass 5, 7a or 9\nClass 6\nClass 7b or 8\nLoad bearing or non-load bearing\n90/90/90\n120/120/120\n180/180/180\n240/240/240\nTable S5C11e Type A construction: FRL of loadbearing internal walls\nLocation\nFRL (in minutes): Structural adequacy / Integrity / Insulation\nClass 2, 3 or 4 part\nClass 5, 7a or 9\nClass 6\nClass 7b or 8\nFire-resisting lift and stair shafts\n90/90/90\n120/120/120\n180/120/120\n240/120/120\nBounding public corridors, public lobbies and the like\n90/90/90\n120/–/–\n180/–/–\n240/–/–\nBetween or bounding sole-occupancy units\n90/90/90\n120/–/–\n180/–/–\n240/–/–\nVentilating, pipe, garbage, and like shafts not used for the discharge of hot products of combustion\n90/90/90\n120/90/90\n180/120/120\n240/120/120\nTable S5C11f Type A construction: FRL of non-loadbearing internal walls\nLocation\nFRL (in minutes): Structural adequacy / Integrity / Insulation\nClass 2, 3 or 4 part\nClass 5, 7a or 9\nClass 6\nClass 7b or 8\nFire-resisting lift and stair shafts\n–/90/90\n–/120/120\n–120/120\n–/120/120\nBounding public corridors, public lobbies and the like\n–/60/60\n–/–/–\n–/–/–\n–/–/–\nBetween or bounding sole-occupancy units\n–/60/60\n–/–/–\n–/–/–\n–/–/–\nVentilating, pipe, garbage, and like shafts not used for the discharge of hot products of combustion\n–/90/90\n–/90/90\n–/120/120\n–/120/120\nTable S5C11g Type A construction: FRL of other building elements not covered by Tables S5C11a to S5C11f\nBuilding element\nFRL (in minutes): Structural adequacy / Integrity / Insulation\nClass 2, 3 or 4 part\nClass 5, 7a or 9\nClass 6\nClass 7b or 8\nOther load bearing internal walls, internal beams, trusses and columns\n90/–/–\n120/–/–\n180/–/–\n240/–/–\nFloors\n90/90/90\n120/120/120\n180/180/180\n240/240/240\nRoofs\n90/60/30\n120/60/30\n180/60/30\n240/90/60","g":"/ncc/s5c11","a19":["Spec C1.1: 3.1 and Table 3"]},{"c":"S5C12","t":"Type A fire-resisting construction — concessions for floors","p":"Specification 5 Fire-resisting construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/5-fire-resisting-construction#S5C12","x":"A floor need not comply with Table S5C11g if—\nit is laid directly on the ground; or\nin a Class 2, 3, 5 or 9 building, the space below is not a storey, does not accommodate motor vehicles, is not a storage or work area, and is not used for any other ancillary purpose; or\nit is a timber stage floor in a Class 9b building laid over a floor having the required FRL and the space below the stage is not used as a dressing room, store room, or the like; or\nit is within a sole-occupancy unit in a Class 2 or 3 building or Class 4 part of a building; or\nit is an open-access floor (for the accommodation of electrical and electronic services and the like) above a floor with the required FRL.","g":"/ncc/s5c12","a19":["Spec C1.1: 3.2"]},{"c":"S5C13","t":"Type A fire-resisting construction — floor loading of Class 5 and 9b buildings: Concession","p":"Specification 5 Fire-resisting construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/5-fire-resisting-construction#S5C13","x":"If a floor in a Class 5 or 9b building is designed for a live load not exceeding 3 kPa—\nthe floor next above (including floor beams) may have an FRL of 90/90/90; or\nthe roof, if that is next above (including roof beams), may have an FRL of 90/60/30.","g":"/ncc/s5c13","a19":["Spec C1.1: 3.3"]},{"c":"S5C14","t":"Type A fire-resisting construction — roof superimposed on concrete slab: Concession","p":"Specification 5 Fire-resisting construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/5-fire-resisting-construction#S5C14","x":"A roof superimposed on a concrete slab roof need not comply with S5C11 as to fire-resisting construction if—\nthe superimposed roof and any construction between it and the concrete slab roof are non-combustible throughout; and\nthe concrete slab roof complies with Table S5C11g.","g":"/ncc/s5c14","a19":["Spec C1.1: 3.4"]},{"c":"S5C15","t":"Type A fire-resisting construction — roof: Concession","p":"Specification 5 Fire-resisting construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/5-fire-resisting-construction#S5C15","x":"A roof need not comply with Table S5C11g if its covering is non-combustible and the building—\nhas a sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17 installed throughout; or\nhas a rise in storeys of 3 or less; or\nis of Class 2 or 3; or\nhas an effective height of not more than 25 m and the ceiling immediately below the roof has a resistance to the incipient spread of fire to the roof space of not less than 60 minutes.","g":"/ncc/s5c15","a19":["Spec C1.1: 3.5"]},{"c":"S5C16","t":"Type A fire-resisting construction — roof lights","p":"Specification 5 Fire-resisting construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/5-fire-resisting-construction#S5C16","x":"If a roof is required to have an FRL or its covering is required to be non-combustible, roof lights or the like installed in that roof must—\nhave an aggregate area of not more than 20% of the roof surface; and\nbe not less than 3 m from—\nany boundary of the allotment other than the boundary with a road or public place; and\nany part of the building which projects above the roof unless that part has the FRL required of a fire wall and any openings in that part of the wall for 6 m vertically above the roof light or the like are protected in accordance with C4D5; and\nany roof light or the like in an adjoining sole-occupancy unit if the walls bounding the unit are required to have an FRL; and\nany roof light or the like in an adjoining fire-separated section of the building; and\nif a ceiling with a resistance to the incipient spread of fire is required, be installed in a way that will maintain the level of protection provided by the ceiling to the roof space.","g":"/ncc/s5c16","a19":["Spec C1.1: 3.6"]},{"c":"S5C17","t":"Type A fire-resisting construction — internal columns and walls: Concession","p":"Specification 5 Fire-resisting construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/5-fire-resisting-construction#S5C17","x":"For a building with an effective height of not more than 25 m and having a roof without an FRL in accordance with S5C15, in the storey immediately below that roof, internal columns other than those referred to in S5C11(1)(d) and internal walls other than fire walls and shaft walls may have—\nin a Class 2 or 3 building: FRL 60/60/60; or\nin a Class 5, 6, 7, 8 or 9 building—\nwith rise in storeys exceeding 3: FRL 60/60/60; or\nwith rise in storeys not exceeding 3: no FRL.","g":"/ncc/s5c17","a19":["Spec C1.1:3.7"]},{"c":"S5C18","t":"Type A fire-resisting construction — open spectator stands and indoor sports stadiums: Concession","p":"Specification 5 Fire-resisting construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/5-fire-resisting-construction#S5C18","x":"In an open spectator stand or indoor sports stadium, the following building elements need not have the FRL specified in Tables S5C11a, S5C11b, S5C11c, S5C11e and S5C11g:\nThe roof if it is non-combustible.\nColumns and load bearing walls supporting only the roof if they are non-combustible.\nAny non-load bearing part of an external wall less than 3 m—\nfrom any fire-source feature to which it is exposed if it has an FRL of not less than –/60/60 and is non-combustible; or\nfrom an external wall of another open spectator stand if it is non-combustible.","g":"/ncc/s5c18","a19":["Spec C1.1: 3.8"]},{"c":"S5C19","t":"Type A fire-resisting construction — carparks","p":"Specification 5 Fire-resisting construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/5-fire-resisting-construction#S5C19","x":"(1) Notwithstanding S5C11, a carpark may comply with this clause if it is—\nan open-deck carpark which is a separate building; or\nprotected with a sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17 and is—\na separate building; or\na part of a building—\nwhich only occupies part of a storey, and is separated from the remaining part by a fire wall; or\nwhich is located above, but not below, another classification, and the floor separating the classifications complies with C3D10; or\nwhich is located above another Class 7 part of the building not used for carparking, and the floor separating the parts complies with Table S5C11g for a Class 7 part other than a carpark; or\nwhich is located below another Class 7 part of the building not used for carparking, and the floor separating the parts complies with this clause.\n(2) For the purposes of this clause, a carpark —\nincludes—\nan administration area associated with the functioning of the carpark; and\nwhere the carpark is sprinklered, is associated with a Class 2 or 3 building and provides carparking for separate sole-occupancy units, each carparking area with an area not greater than 10% of its floor area for purposes ancillary to the sole-occupancy units; but\nexcludes—\nexcept for (a), any area of another classification, or other part of a Class 7 building not used for carparking; and\na building or part of a building specifically intended for the parking of trucks, buses, vans and the like.\n(3) For building elements in a carpark as described in (1) and (2), the following minimum FRLs are applicable:\nExternal wall:\nLess than 3 m from a fire-source feature to which it is exposed:\nLoad bearing: 60/60/60.\nNon-load bearing: –/60/60.\n3 m or more from a fire-source feature to which it is exposed: –/–/–.\nInternal wall:\nLoad bearing, other than one supporting only the roof (not used for carparking): 60/–/–.\nSupporting only the roof (not used for carparking): –/–/–.\nNon-load bearing: –/–/–.\nFire wall:\nFrom the direction used as a carpark: 60/60/60.\nFrom the direction not used as a carpark: as required by Table S5C11d.\nColumns:\nSupporting only the roof (not used for carparking) and 3 m or more from a fire-source feature to which it is exposed: –/–/–.\nSteel column, other than one covered by (i) and one that does not support a part of a building that is not used as a carpark —\n60/–/–; or\nan ESA/M of not greater than 26m2/tonne.\nAny other column not covered by (i) or (ii): 60/–/–.\nBeams:\nSteel floor beam in continuous contact with a concrete floor slab—\n60/–/–; or\nan ESA/M of not greater than 30m2/tonne.\nAny other beam: 60/–/–.\nFire-resisting lift and stair shaft (within the carpark only): 60/60/60.\nFloor slab and vehicle ramp: 60/60/60.\nRoof (not used for carparking): –/–/–.\n(4) For the purposes of sub-clause (3):\nESA/M means the ratio of exposed surface area to mass per unit length.\nRefer to Specification 17 for special requirements for a sprinkler system in a carpark complying with (3) and located within a multi-classified building.","g":"/ncc/s5c19","a19":["Spec C1.1: 3.9 and Table 3.9"]},{"c":"S5C20","t":"Type A fire-resisting construction — Class 2 and 3 buildings: Concession","p":"Specification 5 Fire-resisting construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/5-fire-resisting-construction#S5C20","x":"(1) In a Class 2 or 3 building with a rise in storeys of not more than 3—\nnotwithstanding C2D10(1) and (2) and C3D7, timber framing may be used for—\nexternal walls; and\ncommon walls; and\nthe floor framing of lifts pits; and\nnon-load bearing internal walls which are required to be fire-resisting; and\nnon-load bearing shafts, except shafts used for the discharge of hot products of combustion; and\nspandrels or horizontal construction provided for the purposes of C3D7; and\nnotwithstanding S5C11(1)(c), for load bearing internal walls and load bearing fire walls —\ntimber framing may be used; and\nnon-combustible materials may be used; and\nnotwithstanding S5C3(1)(c), timber framing may be used for a part of a building that provides support to a part of a building constructed of timber framing or non-combustible material in accordance with (a) and (b).\n(2) A building having a rise in storeys of not more than 4 may have the top three storeys constructed in accordance with (1) provided—\nthe lowest storey is used solely for the purpose of parking motor vehicles or for some other ancillary purpose; and\nthe remaining storeys are Class 2 or 3; and\nthe lowest storey’s load bearing elements are constructed of concrete or masonry, including the floor between it and the Class 2 or 3 part of the building above; and\nthe lowest storey and the storey above are separated by construction having an FRL of not less than 90/90/90 with no openings or penetrations that would reduce the fire-resisting performance of that construction except that a doorway in that construction may be protected by a –/60/30 self-closing fire door.\n(3) In a Class 2 or 3 building complying with (1) or (2) and fitted with a sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17, any FRL criterion prescribed in Tables S5C11a, S5C11d, S5C11e, S5C11f and S5C11g —\nfor any floor and any load bearing wall, may be reduced to 60, except any FRL criterion of 90 for an external wall must be maintained when tested from the outside; and\nfor any non-load bearing internal wall, need not apply if—\nit is lined on each side with 13 mm standard grade plasterboard or similar non-combustible material; and\nit extends—\nto the underside of the floor next above; or\nto the underside of a ceiling with a resistance to the incipient spread of fire of 60 minutes; or\nto the underside of a non-combustible roof covering; and\nany insulation installed in the cavity of the wall is non-combustible; and\nany construction joint, space or the like between the top of the wall and the floor, ceiling or roof is smoke sealed with intumescent putty or other suitable material; and\nany doorway in the wall is protected by a self-closing, tight fitting, solid core door not less than 35 mm thick.","g":"/ncc/s5c20","a19":["Spec C1.1: 3.10"]},{"c":"Table S5C21a","t":"Type B construction: FRL of loadbearing parts of external walls","p":"Specification 5 Fire-resisting construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/5-fire-resisting-construction#_cfde28d1-ce19-4ec7-9c4d-10e56b5d5bab","x":"Distance from a fire-source feature | FRL (in minutes) Structural adequacy / Integrity / Insulation\nClass 2, 3 or 4 part | Class 5, 7a or 9 | Class 6 | Class 7b or 8\nLess than 1.5 m | 90/90/90 | 120/120/120 | 180/180/180 | 240/240/240\n1.5 to less than 3 m | 90/60/30 | 120/90/60 | 180/120/90 | 240/180/120\n3 m to less than 9 m | 90/30/30 | 120/30/30 | 180/90/60 | 240/90/60\n9 m to less than 18 m | 90/30/– | 120/30/– | 180/60/– | 240/60/–\n18 m or more | –/–/– | –/–/– | –/–/– | –/–/–","tb":"S5C21","g":"/ncc/table-s5c21a"},{"c":"Table S5C21b","t":"Type B construction: FRL of non-loadbearing parts of external walls","p":"Specification 5 Fire-resisting construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/5-fire-resisting-construction#_4da54f2d-ed18-4133-802e-f97b83f1aec7","x":"Distance from a fire-source feature | FRL (in minutes): Structural adequacy / Integrity / Insulation\nClass 2, 3 or 4 part | Class 5, 7a or 9 | Class 6 | Class 7b or 8\nLess than 1.5 m | –/90/90 | –/120/120 | –/180/180 | –/240/240\n1.5 m to less than 3 m | –/60/30 | –/90/60 | –/120/90 | –/180/120\n3 m or more | –/–/– | –/–/– | –/–/– | –/–/–","tb":"S5C21","g":"/ncc/table-s5c21b"},{"c":"Table S5C21c","t":"Type B construction: FRL of external columns not incorporated in an external wall","p":"Specification 5 Fire-resisting construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/5-fire-resisting-construction#_4737a83b-c3b6-48b6-beb8-1a08f0bcb807","x":"Distance from a fire-source feature | FRL (in minutes): Structural adequacy / Integrity / Insulation\nClass 2, 3 or 4 part | Class 5, 7a or 9 | Class 6 | Class 7b or 8\nLoad bearing column — less than 18 m | 90/–/– | 120/–/– | 180/–/– | 240/–/–\nLoad bearing column — 18 m or more | –/–/– | –/–/– | –/–/– | –/–/–\nNon-load bearing column | –/–/– | –/–/– | –/–/– | –/–/–","tb":"S5C21","g":"/ncc/table-s5c21c"},{"c":"Table S5C21d","t":"Type B construction: FRL of common walls and fire walls","p":"Specification 5 Fire-resisting construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/5-fire-resisting-construction#_a9047cc8-11d8-47d3-85ec-250ec243b002","x":"Wall type | FRL (in minutes): Structural adequacy / Integrity / Insulation\nClass 2, 3 or 4 part | Class 5, 7a or 9 | Class 6 | Class 7b or 8\nLoad bearing or non-load bearing | 90/90/90 | 120/120/120 | 180/180/180 | 240/240/240","tb":"S5C21","g":"/ncc/table-s5c21d"},{"c":"Table S5C21e","t":"Type B construction: FRL of loadbearing internal walls","p":"Specification 5 Fire-resisting construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/5-fire-resisting-construction#_257de7c8-0508-45de-9da3-4f6feef05a96","x":"Location | FRL (in minutes): Structural adequacy / Integrity / Insulation\nClass 2, 3 or 4 part | Class 5, 7a or 9 | Class 6 | Class 7b or 8\nFire-resisting lift and stair shafts | 90/90/90 | 120/120/120 | 180/120/120 | 240/120/120\nBounding public corridors, public lobbies and the like | 60/60/60 | 120/–/– | 180/–/– | 240/–/–\nBetween or bounding sole-occupancy units | 60/60/60 | 120/–/– | 180/–/– | 240/–/–","tb":"S5C21","g":"/ncc/table-s5c21e"},{"c":"Table S5C21f","t":"Type B construction: FRL of non-loadbearing internal walls","p":"Specification 5 Fire-resisting construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/5-fire-resisting-construction#_af5ef8c3-991b-4217-bc01-4ea40a096fce","x":"Location | FRL (in minutes): Structural adequacy / Integrity / Insulation\nClass 2, 3 or 4 part | Class 5, 7a or 9 | Class 6 | Class 7b or 8\nFire-resisting stair shafts | –/90/90 | –/120/120 | –/120/120 | –/120/120\nBounding public corridor, public lobbies and the like | –/60/60 | –/–/– | –/–/– | –/–/–\nBetween or bounding sole-occupancy units | –/60/60 | –/–/– | –/–/– | –/–/–","tb":"S5C21","g":"/ncc/table-s5c21f"},{"c":"Table S5C21g","t":"Type B construction: FRL of other building elements not covered by Tables S5C21a to S5C21f","p":"Specification 5 Fire-resisting construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/5-fire-resisting-construction#_6b4d4f3e-fd2a-435a-80c2-430be2d867f9","x":"Building element | FRL (in minutes): Structural adequacy / Integrity / Insulation\nClass 2, 3 or 4 part | Class 5, 7a or 9 | Class 6 | Class 7b or 8\nOther load bearing internal walls and columns | 60/–/– | 120/–/– | 180/–/– | 240/–/–\nRoofs | –/–/– | –/–/– | –/–/– | –/–/–","tb":"S5C21","g":"/ncc/table-s5c21g"},{"c":"S5C21","t":"Type B fire-resisting construction — fire-resistance of building elements","p":"Specification 5 Fire-resisting construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/5-fire-resisting-construction#S5C21","x":"(1) In a building required to be of Type B construction—\neach building element listed in Tables S5C21a, S5C21b, S5C21c, S5C21d, S5C21e, S5C21f and S5C21g, and any beam or column incorporated in it, must have an FRL not less than that listed in the Tables for the particular class of building concerned; and\nif a stair shaft supports any floor or a structural part of it—\nthe floor or part must have an FRL of 60/–/– or more; or\nthe junction of the stair shaft must be constructed so that the floor or part will be free to sag or fall in a fire without causing structural damage to the shaft; and\nany internal wall which is required to have an FRL with respect to integrity and insulation, except a wall that bounds a sole-occupancy unit in the topmost (or only) storey and there is only one unit in that storey, must extend to—\nthe underside of the floor next above if that floor has an FRL of at least 30/30/30; or\nthe underside of a ceiling having a resistance to the incipient spread of fire to the space above itself of not less than 60 minutes; or\nthe underside of the roof covering if it is non-combustible and, except for roof battens with dimensions of 75 mm x 50 mm or less or sarking-type material, must not be crossed by timber or other combustible building elements; or\n450 mm above the roof covering if it is combustible; and\na load bearing internal wall and a load bearing fire wall (including those that are part of a load bearing shaft) must be constructed from—\nconcrete; or\nmasonry; or\nsubject to (2), fire-protected timber; or\nany combination of (i) to (iii); and\nin a Class 5, 6, 7, 8 or 9 building, in the storey immediately below the roof, internal columns and internal walls other than fire walls and shaft walls, need not comply with Tables S5C21e, S5C21f and S5C21g; and\nin a Class 2 or 3 building, except where within the one sole-occupancy units, or a Class 9a health-care building or a Class 9b building, a floor separating storeys or above a space for the accommodation of motor vehicles or used for storage or any other ancillary purpose, must—\nbe constructed so that it is at least of the standard achieved by a floor/ceiling system incorporating a ceiling which has a resistance to the incipient spread of fire to the space above itself of not less than 60 minutes; or\nhave an FRL of at least 30/30/30; or\nhave a fire-protective covering on the underside of the floor, including beams incorporated in it, if the floor is combustible or of metal; and\nin a Class 9c building a floor above a space for the accommodation of motor vehicles or used for storage or any other ancillary purpose, and any column supporting the floor must—\nbe constructed so that it is at least of the standard achieved by a floor/ceiling system incorporating a ceiling which has a resistance to the incipient spread of fire to the space above itself of not less than 60 minutes; or\nhave an FRL of at least 30/30/30; or\nhave a fire-protective covering on the underside of the floor, including beams incorporated in it, if the floor is combustible or of metal.\n(2) For the purposes of (1)(d)(iii), fire-protected timber may be used, provided that—\nthe building is—\na separate building; or\na part of a building—\nwhich only occupies part of a storey, and is separated from the remaining part by a fire wall; or\nwhich is located above or below a part not containing fire-protected timber and the floor between the adjoining parts is provided with an FRL not less than that prescribed for a fire wall for the lower storey; and\nthe building has an effective height of not more than 25 m; and\nthe building has a sprinkler system (other than a FPAA101D or FPAA101H system) throughout complying with Specification 17; and\nany insulation installed in the cavity of the timber building element required to have an FRL is non-combustible; and\ncavity barriers are provided in accordance with Specification 9.\n(3) For the purposes of Table S5C21a and Table S5C21b, external wall includes any column and other building element incorporated within it or other external building element.\nTable S5C21a Type B construction: FRL of loadbearing parts of external walls\nDistance from a fire-source feature\nFRL (in minutes) Structural adequacy / Integrity / Insulation\nClass 2, 3 or 4 part\nClass 5, 7a or 9\nClass 6\nClass 7b or 8\nLess than 1.5 m\n90/90/90\n120/120/120\n180/180/180\n240/240/240\n1.5 to less than 3 m\n90/60/30\n120/90/60\n180/120/90\n240/180/120\n3 m to less than 9 m\n90/30/30\n120/30/30\n180/90/60\n240/90/60\n9 m to less than 18 m\n90/30/–\n120/30/–\n180/60/–\n240/60/–\n18 m or more\n–/–/–\n–/–/–\n–/–/–\n–/–/–\nTable S5C21b Type B construction: FRL of non-loadbearing parts of external walls\nDistance from a fire-source feature\nFRL (in minutes): Structural adequacy / Integrity / Insulation\nClass 2, 3 or 4 part\nClass 5, 7a or 9\nClass 6\nClass 7b or 8\nLess than 1.5 m\n–/90/90\n–/120/120\n–/180/180\n–/240/240\n1.5 m to less than 3 m\n–/60/30\n–/90/60\n–/120/90\n–/180/120\n3 m or more\n–/–/–\n–/–/–\n–/–/–\n–/–/–\nTable S5C21c Type B construction: FRL of external columns not incorporated in an external wall\nDistance from a fire-source feature\nFRL (in minutes): Structural adequacy / Integrity / Insulation\nClass 2, 3 or 4 part\nClass 5, 7a or 9\nClass 6\nClass 7b or 8\nLoad bearing column — less than 18 m\n90/–/–\n120/–/–\n180/–/–\n240/–/–\nLoad bearing column — 18 m or more\n–/–/–\n–/–/–\n–/–/–\n–/–/–\nNon-load bearing column\n–/–/–\n–/–/–\n–/–/–\n–/–/–\nTable S5C21d Type B construction: FRL of common walls and fire walls\nWall type\nFRL (in minutes): Structural adequacy / Integrity / Insulation\nClass 2, 3 or 4 part\nClass 5, 7a or 9\nClass 6\nClass 7b or 8\nLoad bearing or non-load bearing\n90/90/90\n120/120/120\n180/180/180\n240/240/240\nTable S5C21e Type B construction: FRL of loadbearing internal walls\nLocation\nFRL (in minutes): Structural adequacy / Integrity / Insulation\nClass 2, 3 or 4 part\nClass 5, 7a or 9\nClass 6\nClass 7b or 8\nFire-resisting lift and stair shafts\n90/90/90\n120/120/120\n180/120/120\n240/120/120\nBounding public corridors, public lobbies and the like\n60/60/60\n120/–/–\n180/–/–\n240/–/–\nBetween or bounding sole-occupancy units\n60/60/60\n120/–/–\n180/–/–\n240/–/–\nTable S5C21f Type B construction: FRL of non-loadbearing internal walls\nLocation\nFRL (in minutes): Structural adequacy / Integrity / Insulation\nClass 2, 3 or 4 part\nClass 5, 7a or 9\nClass 6\nClass 7b or 8\nFire-resisting stair shafts\n–/90/90\n–/120/120\n–/120/120\n–/120/120\nBounding public corridor, public lobbies and the like\n–/60/60\n–/–/–\n–/–/–\n–/–/–\nBetween or bounding sole-occupancy units\n–/60/60\n–/–/–\n–/–/–\n–/–/–\nTable S5C21g Type B construction: FRL of other building elements not covered by Tables S5C21a to S5C21f\nBuilding element\nFRL (in minutes): Structural adequacy / Integrity / Insulation\nClass 2, 3 or 4 part\nClass 5, 7a or 9\nClass 6\nClass 7b or 8\nOther load bearing internal walls and columns\n60/–/–\n120/–/–\n180/–/–\n240/–/–\nRoofs\n–/–/–\n–/–/–\n–/–/–\n–/–/–","g":"/ncc/s5c21","a19":["Spec C1.1: 4.1 and Table 4"]},{"c":"S5C22","t":"Type B fire-resisting construction — carparks","p":"Specification 5 Fire-resisting construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/5-fire-resisting-construction#S5C22","x":"(1) Notwithstanding S5C21, a carpark may comply with this clause if it is—\nan open-deck carpark which is a separate building; or\nprotected with a sprinkler system (other than FPAA101D or FPAA101H system) complying with Specification 17 and is—\na separate building; or\na part of a building, and if occupying only part of a storey, is separated from the remaining part by a fire wall.\n(2) For the purposes of this clause, a carpark —\nincludes—\nan administration area associated with the functioning of the carpark; and\nwhere the carpark is sprinklered, is associated with a Class 2 or 3 building and provides carparking for separate sole-occupancy units each carparking area with an area not greater than 10% of its floor area for purposes ancillary to the sole-occupancy units; but\nexcludes—\nexcept for (a), any area of another classification, or other part of a Class 7 building not used for carparking; and\na building or part of a building specifically intended for the parking of trucks, buses, vans and the like.\n(3) For building elements in a carpark as described in (1) and (2), the following minimum FRLs are applicable:\nExternal walls:\nLess than 3 m from a fire-source feature to which it is exposed:\nLoad bearing: 60/60/60.\nNon-load bearing: –/60/60.\n3 m or more from a fire-source feature to which it is exposed: –/–/–.\nInternal walls:\nLoad bearing, other than one supporting only the roof (not used for carparking): 60/–/–.\nSupporting only the roof (not used for carparking): –/–/–.\nNon-load bearing: –/–/–.\nFire walls:\nFrom the direction used as a carpark: 60/60/60.\nFrom the direction not used as a carpark: as required by Table S5C21d.\nColumns:\nSupporting only the roof (not used for carparking) and 3 m or more from a fire-source feature to which it is exposed: –/–/–.\nSteel column, other than one covered by (i) and one that does not support a part of a building that is not used as a carpark —\n60/–/–; or\nan ESA/M of not greater than 26 m2/tonne.\nAny other column not covered by (i) or (ii): 60/–/–.\nBeams:\nSteel floor beam less than 3 m from a fire-source feature in continuous contact with a concrete floor slab—\n60/–/–; or\nan ESA/M of not greater than 30 m2/tonne.\nAny other beam less than 3 m from a fire-source feature: 60/–/–.\nAny beam 3 m or more from a fire-source feature: –/–/–.\nLift shaft: –/–/–.\nFire-resisting stair shaft (within the carpark only): 60/60/60.\nRoof, floor slab and vehicle ramp: –/–/–.\n(4) For the purposes of (3), ESA/M means the ratio of exposed surface area to mass per unit length.","g":"/ncc/s5c22","a19":["Spec C1.1: 4.2 and Table 4.2"]},{"c":"S5C23","t":"Type B fire-resisting construction — Class 2 and 3 buildings: Concession","p":"Specification 5 Fire-resisting construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/5-fire-resisting-construction#S5C23","x":"(1) In a Class 2 or 3 building with a rise in storeys of not more than 2—\nnotwithstanding C2D10(1) and (2), timber framing may be used for—\nexternal walls; and\ncommon walls; and\nthe floor framing of lifts pits; and\nnon-load bearing internal walls which are required to be fire-resisting; and\nnon-load bearing shafts, except shafts used for the discharge of hot products of combustion; and\nnotwithstanding S5C21(1)(d), for load bearing internal walls and load bearing fire walls —\ntimber framing may be used; and\nnon-combustible materials may be used; and\nnotwithstanding S5C3(1)(c), timber framing may be used for a part of a building that provides support to a part of a building constructed of timber framing or non-combustible material in accordance with (a) and (b).\n(2) A building having a rise in storeys of not more than 2 may have the top storey constructed in accordance with (1) provided—\nthe lowest storey is used solely for the purpose of parking motor vehicles or for some other ancillary purpose; and\nthe remaining storeys are Class 2 or 3; and\nthe lowest storey’s load bearing elements are constructed of concrete or masonry, including the floor between it and the Class 2 or 3 part of the building above; and\nthe lowest storey and the storey above are separated by construction having an FRL of not less than 90/90/90 with no openings or penetrations that would reduce the fire-resisting performance of that construction except that a doorway in that construction may be protected by a –/60/30 self-closing fire door.\n(3) In a Class 2 or 3 building complying with (1) or (2) and fitted with a sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17, any FRL criterion prescribed in Tables S5C21a, S5C21d, S5C21e, S5C21f and S5C21g; and—\nfor any load bearing wall, may be reduced to 60, except any FRL criterion of 90 for an external wall must be maintained when tested from the outside; and\nfor any non-load bearing internal wall, need not apply, if—\nit is lined on both sides with 13 mm standard grade plasterboard or similar non-combustible material; and\nit extends—\nto the underside of the floor next above if that floor has an FRL of at least 30/30/30 or is lined on the underside with a fire-protective covering; or\nto the underside of a ceiling with a resistance to the incipient spread of fire of 60 minutes; or\nto the underside of a non-combustible roof covering; and\nany insulation installed in the cavity of the wall is non-combustible; and\nany construction joints, spaces and the like between the top of the wall and the floor, ceiling or roof is smoke sealed with intumescent putty or other suitable material.","g":"/ncc/s5c23","a19":["Spec C1.1: 4.3"]},{"c":"Table S5C24a","t":"Type C construction: FRL of parts of external walls","p":"Specification 5 Fire-resisting construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/5-fire-resisting-construction#_538e144c-77db-46d5-b349-2829045d4e17","x":"Distance from a fire-source feature | FRL (in minutes): Structural adequacy / Integrity / Insulation\nClass 2, 3 or 4 part | Class 5, 7a or 9 | Class 6 | Class 7b or 8\nLess than 1.5 m | 90/90/90 | 90/90/90 | 90/90/90 | 90/90/90\n1.5 to less than 3 m | –/–/– | 60/60/60 | 60/60/60 | 60/60/60\n3 m or more | –/–/– | –/–/– | –/–/– | –/–/–","tb":"S5C24","g":"/ncc/table-s5c24a"},{"c":"Table S5C24b","t":"Type C construction: FRL of external columns not incorporated into an external wall","p":"Specification 5 Fire-resisting construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/5-fire-resisting-construction#_fdc63684-4efe-4629-bc7b-a2a6fe3897d7","x":"Distance from a fire-source feature | FRL (in minutes): structural adequacy / Integrity / Insulation\nClass 2, 3 or 4 part | Class 5, 7a or 9 | Class 6 | Class 7b or 8\nLess than 1.5 m | 90/–/– | 90/–/– | 90/–/– | 90/–/–\n1.5 to less than 3 m | –/–/– | 60/–/– | 60/–/– | 60/–/–\n3 m or more | –/–/– | –/–/– | –/–/– | –/–/–","tb":"S5C24","g":"/ncc/table-s5c24b"},{"c":"Table S5C24c","t":"Type C construction: FRL of common walls and fire walls","p":"Specification 5 Fire-resisting construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/5-fire-resisting-construction#_07fffac1-9823-4200-85f1-11a6b31ecb3d","x":"Wall type | FRL (in minutes): Structural adequacy / Integrity / Insulation\nClass 2, 3 or 4 part | Class 5, 7a or 9 | Class 6 | Class 7b or 8\nLoad bearing or non-load bearing | 90/90/90 | 90/90/90 | 90/90/90 | 90/90/90","tb":"S5C24","g":"/ncc/table-s5c24c"},{"c":"Table S5C24d","t":"Type C construction: FRL of internal walls","p":"Specification 5 Fire-resisting construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/5-fire-resisting-construction#_686687a4-a758-4726-ae8c-121f0bf91592","x":"Location | FRL (in minutes): Structural adequacy / Integrity / Insulation\nClass 2, 3 or 4 part | Class 5, 7a or 9 | Class 6 | Class 7b or 8\nBounding public corridors, public lobbies and the like | 60/60/60 | –/–/– | –/–/– | –/–/–\nBetween or bounding sole-occupancy units | 60/60/60 | –/–/– | –/–/– | –/–/–\nBounding a stair if required to be rated | 60/60/60 | 60/60/60 | 60/60/60 | 60/60/60","tb":"S5C24","g":"/ncc/table-s5c24d"},{"c":"Table S5C24e","t":"Type C construction: FRL of roof","p":"Specification 5 Fire-resisting construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/5-fire-resisting-construction#_8699b152-5e1f-47ed-b055-4106c3951105","x":"Location | FRL (in minutes): Structural adequacy / Integrity / Insulation\nClass 2, 3 or 4 part | Class 5, 7a or 9 | Class 6 | Class 7b or 8\nRoofs | –/–/– | –/–/– | –/–/– | –/–/–","tb":"S5C24","g":"/ncc/table-s5c24e"},{"c":"S5C24","t":"Type C fire-resisting construction — fire-resistance of building elements","p":"Specification 5 Fire-resisting construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/5-fire-resisting-construction#S5C24","x":"(1) In a building required to be of Type C construction—\na building element listed in Tables S5C24a, S5C24b, S5C24c, S5C24d and S5C24e and any beam or column incorporated in it, must have an FRL not less than that listed in those Tables for the particular Class of building concerned; and\nan external wall that is required by Table S5C24a to have an FRL need only be tested from the outside to satisfy the requirement; and\na fire wall or an internal wall bounding a sole-occupancy unit or separating adjoining units must comply with Specification 6 if it is of lightweight construction and is required to have an FRL; and\nin a Class 2 or 3 building, an internal wall which is required by S5C24c or S5C24d to have an FRL must extend—\nto the underside of the floor next above if that floor has an FRL of at least 30/30/30 or a fire-protective covering on the underside of the floor; or\nto the underside of a ceiling having a resistance to the incipient spread of fire to the space above itself of not less than 60 minutes; or\nto the underside of the roof covering if it is non-combustible, and except for roof battens with dimensions of 75 mm x 50 mm or less or sarking-type material, must not be crossed by timber or other combustible building elements; or\n450 mm above the roof covering if it is combustible; and\nin a Class 2 or 3 building, except where within the one sole-occupancy unit, or a Class 9a health-care building, or a Class 9b building, a floor separating storeys, or above a space for the accommodation of motor vehicles or used for storage or any other ancillary purpose, and any column supporting the floor, must—\nhave an FRL of at least 30/30/30; or\nhave a fire-protective covering on the underside of the floor including beams incorporated in it and around the column, if the floor or column is combustible or of metal; and\nin a Class 9c building a floor above a space for the accommodation of motor vehicles or used for storage or any other ancillary purpose, and any column supporting the floor, must—\nhave an FRL of at least 30/30/30; or\nhave a fire-protective covering on the underside of the floor including beams incorporated in it and around the column, if the floor or column is combustible or of metal.\n(2) For the purposes of Table S5C24a and Table S5C24b, external wall includes any column and other building element incorporated within it or other external building element.\nTable S5C24a Type C construction: FRL of parts of external walls\nDistance from a fire-source feature\nFRL (in minutes): Structural adequacy / Integrity / Insulation\nClass 2, 3 or 4 part\nClass 5, 7a or 9\nClass 6\nClass 7b or 8\nLess than 1.5 m\n90/90/90\n90/90/90\n90/90/90\n90/90/90\n1.5 to less than 3 m\n–/–/–\n60/60/60\n60/60/60\n60/60/60\n3 m or more\n–/–/–\n–/–/–\n–/–/–\n–/–/–\nTable S5C24b Type C construction: FRL of external columns not incorporated into an external wall\nDistance from a fire-source feature\nFRL (in minutes): structural adequacy / Integrity / Insulation\nClass 2, 3 or 4 part\nClass 5, 7a or 9\nClass 6\nClass 7b or 8\nLess than 1.5 m\n90/–/–\n90/–/–\n90/–/–\n90/–/–\n1.5 to less than 3 m\n–/–/–\n60/–/–\n60/–/–\n60/–/–\n3 m or more\n–/–/–\n–/–/–\n–/–/–\n–/–/–\nTable S5C24c Type C construction: FRL of common walls and fire walls\nWall type\nFRL (in minutes): Structural adequacy / Integrity / Insulation\nClass 2, 3 or 4 part\nClass 5, 7a or 9\nClass 6\nClass 7b or 8\nLoad bearing or non-load bearing\n90/90/90\n90/90/90\n90/90/90\n90/90/90\nTable S5C24d Type C construction: FRL of internal walls\nLocation\nFRL (in minutes): Structural adequacy / Integrity / Insulation\nClass 2, 3 or 4 part\nClass 5, 7a or 9\nClass 6\nClass 7b or 8\nBounding public corridors, public lobbies and the like\n60/60/60\n–/–/–\n–/–/–\n–/–/–\nBetween or bounding sole-occupancy units\n60/60/60\n–/–/–\n–/–/–\n–/–/–\nBounding a stair if required to be rated\n60/60/60\n60/60/60\n60/60/60\n60/60/60\nTable S5C24e Type C construction: FRL of roof\nLocation\nFRL (in minutes): Structural adequacy / Integrity / Insulation\nClass 2, 3 or 4 part\nClass 5, 7a or 9\nClass 6\nClass 7b or 8\nRoofs\n–/–/–\n–/–/–\n–/–/–\n–/–/–","g":"/ncc/s5c24","a19":["Spec C1.1: 5.1 and Table 5"]},{"c":"S5C25","t":"Type C fire-resisting construction — carparks","p":"Specification 5 Fire-resisting construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/5-fire-resisting-construction#S5C25","x":"(1) Notwithstanding S5C24, a carpark may comply with this clause if it is an open-deck carpark or is protected with a sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17 and is—\na separate building; or\na part of a building, and if occupying only part of a storey, is separated from the remaining part by a fire wall.\n(2) For the purposes of this clause, a carpark —\nincludes—\nan administration area associated with the functioning of the carpark; and\nwhere the carpark is sprinklered, is associated with a Class 2 or 3 building and provides carparking for separate sole-occupancy units, each carparking area with an area not greater than 10% of its floor area for purposes ancillary to the sole-occupancy units; but\nexcludes—\nexcept for (a), any area of another classification, or other part of a Class 7 building not used for carparking; and\na building or part of a building specifically intended for the parking of trucks, buses, vans and the like.\n(3) For building elements in a carpark as described in (1) and (2), the following minimum FRLs are applicable:\nExternal walls:\nLess than 1.5 m from a fire-source feature to which it is exposed:\nLoad bearing: 60/60/60.\nNon-load bearing: –/60/60.\n1.5 m or more from a fire-source feature to which it is exposed: –/–/–.\nInternal walls: –/–/–.\nFire walls:\nFrom the direction used as a carpark: 60/60/60.\nFrom the direction not used as a carpark: 90/90/90.\nColumns:\nSteel column less than 1.5 m from a fire-source feature —\n60/–/–; or\nESA/M not greater than 26 m2/tonne.\nAny other column not less than 1.5 m from a fire-source feature: 60/–/–.\nAny other column not covered by (i) or (ii): –/–/–.\nBeams:\nSteel floor beam, less than 1.5 m from a fire-source feature, in continuous contact with a concrete floor slab—\n60/–/–; or\nan ESA/M of not greater than 30 m2/tonne.\nany other beam: 60/–/–.\nmore than 1.5 m from a fire-source feature: –/–/–.\nRoof, floor slab and vehicle ramp: –/–/–.\n(4) For the purposes of (3), ESA/M means the ratio of exposed surface area to mass per unit length.","g":"/ncc/s5c25","a19":["Spec C1.1: 5.2 and Table 5.2"]},{"c":"S6C1","t":"Scope","p":"Specification 6 Structural tests for lightweight construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/6-structural-tests-lightweight-construction#S6C1","x":"This Specification describes tests to be applied to and criteria to be satisfied by a wall system of lightweight construction.","g":"/ncc/s6c1","a19":["Spec C1.8: 1"]},{"c":"S6C2","t":"Application","p":"Specification 6 Structural tests for lightweight construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/6-structural-tests-lightweight-construction#S6C2","x":"A wall system need not be tested in accordance with this Specification for static pressure or impact if it is designed and constructed in accordance with the Deemed-to-Satisfy Provisions of Part B1 to resist the appropriate pressures and impacts defined in this Specification.","g":"/ncc/s6c2","a19":["Spec C1.8: 2"]},{"c":"S6C3","t":"Walls of certain Class 9b buildings","p":"Specification 6 Structural tests for lightweight construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/6-structural-tests-lightweight-construction#S6C3","x":"(1) Lightweight construction forming—\na wall of a lift shaft and stair s haft; and\nan external wall and internal wall bounding a public corridor, public lobby or the like, including a fire-isolated and non fire-isolated passageway or ramp,\nin spectator stand, sports stadium, cinema or theatre, railway or bus station or airport terminal, must be subjected to the tests and must fulfil the criteria set out in (2).\n(2) For the purposes of (1), the following tests and criteria apply:\nThe materials tests of S6C10(a) and the criteria of S6C11(a).\nA static test by the imposition of a uniformly distributed load of 1.0 kPa (or its equivalent) in accordance with S6C10(b) and the damage and deflection criteria of S6C11(b) and (c) respectively.\nA dynamic test by the fall of the impact bag through a height of 350 mm in accordance with S6C10(c) and the damage and deflection criteria of S6C11(b) and (d) respectively.\nThe surface indentation test of S6C10(d) and the surface indentation criterion of S6C11(e).","g":"/ncc/s6c3","a19":["Spec C1.8: 3.1"]},{"c":"S6C4","t":"Walls of shafts and fire-isolated exits generally","p":"Specification 6 Structural tests for lightweight construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/6-structural-tests-lightweight-construction#S6C4","x":"A wall of lightweight construction that is required to be fire-resisting and which bounds a lift shaft, stair shaft, or service shaft, fire-isolated passageway or fire-isolated ramp must be subjected to the following tests and must fulfil the following criteria:\nThe materials tests of S6C10(a) and the criteria of S6C11(a).\nA static test by the imposition of a uniformly distributed load of 0.35 kPa (or its equivalent) in accordance with S6C10(b) and the damage and deflection criteria of S6C11(b) and (c) respectively.\nA dynamic test by the fall of the impact bag through a height of 150 mm in accordance with S6C10(c) and the damage and deflection criteria of S6C11(b) and (d) respectively.\nThe surface indentation test of S6C10(d) and the surface indentation criterion of S6C11(e).","g":"/ncc/s6c4","a19":["Spec C1.8: 3.2"]},{"c":"S6C5","t":"Additional requirements for lift shafts","p":"Specification 6 Structural tests for lightweight construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/6-structural-tests-lightweight-construction#S6C5","x":"(1) In addition to the requirements of S6C3 and S6C4, a wall system for use in a lift shaft that is required to be fire-resisting must be subjected to dynamic test by the imposition of—\nwhere the lift car speed is 7 m/s or less — 106 cycles of a uniformly distributed load between 0 and 0.2 kPa (or its equivalent); or\nwhere the lift car speed is greater than 7 m/s — 106 cycles of a uniformly distributed load between 0 and 0.35 kPa (or its equivalent) in accordance with S6C10(e) and must fulfil the damage criteria of S6C11(b).\n(2) The wall system must be subjected to the static test in accordance with S6C4(b) after the successful conclusion of the dynamic test specified in (1).","g":"/ncc/s6c5","a19":["Spec C1.8: 3.3"]},{"c":"S6C6","t":"Walls generally","p":"Specification 6 Structural tests for lightweight construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/6-structural-tests-lightweight-construction#S6C6","x":"An external wall and internal wall of lightweight construction that is required to be fire-resisting, other than one covered by S6C3, S6C4 or S6C5, must be subjected to the following tests and must fulfil the following criteria:\nThe materials tests of S6C10(a) and the criteria of S6C11(a).\nA static test by the imposition of a uniformly distributed load of 0.25 kPa (or its equivalent) in accordance with S6C10(b) and the damage and deflection criteria of S6C11(b) and (c) respectively.\nA dynamic test by fall of the impact bag through a height of 100 mm in accordance with S6C10(c) and the damage and deflection criteria of S6C11(b) and (d) respectively.\nThe surface indentation test of S6C10(d) and the surface indentation criterion of S6C11(e).","g":"/ncc/s6c6","a19":["Spec C1.8: 3.4"]},{"c":"S6C7","t":"General requirements for testing","p":"Specification 6 Structural tests for lightweight construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/6-structural-tests-lightweight-construction#S6C7","x":"Testing must be carried out on either—\nconstruction in-situ; or\na laboratory specimen of the construction.","g":"/ncc/s6c7","a19":["Spec C1.8: 4.1"]},{"c":"S6C8","t":"Testing in-situ","p":"Specification 6 Structural tests for lightweight construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/6-structural-tests-lightweight-construction#S6C8","x":"If testing is carried out in-situ, it must be done on that part of the construction least likely, because of the particular combination of the height of the walls, the support conditions and other aspects of the construction, to resist the loads.","g":"/ncc/s6c8","a19":["Spec C1.8: 4.2"]},{"c":"S6C9","t":"Testing of specimens","p":"Specification 6 Structural tests for lightweight construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/6-structural-tests-lightweight-construction#S6C9","x":"If a laboratory specimen is tested, the specimen must span only in the direction corresponding to the height of the wall and testing must be done in accordance with either (a) or (b) below:\nThe test specimen—\nheight (or length, if the specimen is tested horizontally) must be identical with the height between supports in the actual construction; and\nmust be supported at the top and bottom (or at each end if tested horizontally) by components identical with, and in a manner identical with, the actual construction.\nIf the distance between supports of the actual construction is more than 3 m, then a smaller specimen may be tested but—\nthe distance between supports must be not less than 3 m; and\nforces, reactions and support conditions must be modelled so as to reproduce the behaviour of the actual construction if it were tested in-situ.","g":"/ncc/s6c9","a19":["Spec C1.8: 4.3"]},{"c":"S6C10","t":"Test methods","p":"Specification 6 Structural tests for lightweight construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/6-structural-tests-lightweight-construction#S6C10","x":"Tests must be carried out in accordance with the following:\nMaterial tests — The methods specified for the constituent materials of the construction of the standards adopted by reference in the NCC.\nFor resistance to static pressure — The provisions for testing walls under transverse load in ASTM E72-15, except that—\nsupport conditions must be as specified in S6C9; and\nequivalent load shall mean the quarter-point load that produces the same deflection or central moment as appropriate; and\nthe timber species nominated in that standard may be substituted with a different species.\nFor resistance to impact — The provisions for testing wall systems in ASTM E695-03, except that—\nthe point of impact must be set 1.5 m above finished floor level or 1.5 m above the part of the specimen that corresponds to finished floor level; and\nthe impact bag must be not less than 225 mm in diameter and not more than 260 mm in diameter and have a mass of not less than 27.2 kg or more than 27.3 kg; and\nthe mass must be achieved by putting loose, dry sand into the bag and must be adjusted before each series of impact tests; and\nwhere the impact bag and suspension cannot be vertical at the instant of impact on a curved surface or an inclined surface, the height of drop is the net height at the point of impact.\nFor resistance to surface indentation — The test for resistance to surface indentation must be carried out at three points on the surface of an undamaged sample sheet as follows:\nA steel ball of 10 mm diameter with a load of 150 N must be placed gently on the surface of the sheet and allowed to remain in position for 5 minutes.\nThe ball and load must then be removed and the diameter of each impression of the ball on the surface measured.\nFor resistance of lift shaft construction to repetitive load — As for (b) except that—\nit is sufficient to test one specimen with the pressure applied from the side of the construction on which the lift will operate; and\nthe load must be applied dynamically at a frequency not less than 1 Hz and not more than 3 Hz; and\nequivalent load shall mean the quarter-point load that produces the same central moment as the distributed load.","g":"/ncc/s6c10","a19":["Spec C1.8: 5"]},{"c":"S6C11","t":"Criteria for compliance","p":"Specification 6 Structural tests for lightweight construction","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/6-structural-tests-lightweight-construction#S6C11","x":"The wall system or the specimen of it must fulfil the following criteria:\nMaterials — Materials must comply with the applicable standard adopted by reference in the NCC.\nDamage — There must be no crack, penetration or permanent surface-deformation to a depth of more than 0.5 mm or any other non-elastic deformation or fastener failure.\nDeflection — Static pressure — Under static pressure the deflection must not be more than—\n1/240th of the height between supports; or\nfor construction other than a lift shaft — 30 mm; or\nfor a lift shaft — 20 mm.\nDeflection — Impact — Under impact the instantaneous deflection must not be more than—\n1/120th of the height of the wall between supports; or\nfor construction other than a lift shaft — 30 mm; or\nfor a lift shaft — 20 mm.\nSurface indentation — No impression must be more than 5 mm in diameter.","g":"/ncc/s6c11","a19":["Spec C1.8: 6"]},{"c":"S7C1","t":"Scope","p":"Specification 7 Fire hazard properties","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/7-fire-hazard-properties#S7C1","x":"This Specification sets out requirements in relation to the fire hazard properties of linings, materials and assemblies in Class 2 to 9 buildings as set out in Table S7C2.","g":"/ncc/s7c1","a19":["Spec C1.10: 1"]},{"c":"Table S7C2","t":"Fire hazard property requirements","p":"Specification 7 Fire hazard properties","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/7-fire-hazard-properties#_bc41460c-9b05-4aca-93cf-d7cda378ace8","x":"Lining, material or assembly | Requirement\nFloor linings and floor coverings | S7C3\nWall linings and ceiling linings | S7C4\nAir-handling ductwork | S7C5\nLift cars | S7C6\nIn fire control rooms subject to Specification 6 and fire isolated exits | S7C7\nIn Class 9b buildings used as a theatre, public hall or the like — fixed seating in the audience area or auditorium; and a proscenium curtain required by Specification 32 | S7C7\nEscalators, moving walkways and non-required non-fire-isolated stairways or pedestrian ramps subject to Specification 14 | S7C7\nSarking-type material | S7C7\nAttachments to internal floors, walls and ceilings | S7C7\nOther materials including insulation | S7C7","tb":"S7C2","g":"/ncc/table-s7c2"},{"c":"S7C2","t":"Application","p":"Specification 7 Fire hazard properties","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/7-fire-hazard-properties#S7C2","x":"Linings, materials and assemblies must comply with the appropriate requirement described in Table S7C2.\nTable S7C2 Fire hazard property requirements\nLining, material or assembly\nRequirement\nFloor linings and floor coverings\nS7C3\nWall linings and ceiling linings\nS7C4\nAir-handling ductwork\nS7C5\nLift cars\nS7C6\nIn fire control rooms subject to Specification 6 and fire isolated exits\nS7C7\nIn Class 9b buildings used as a theatre, public hall or the like — fixed seating in the audience area or auditorium; and a proscenium curtain required by Specification 32\nS7C7\nEscalators, moving walkways and non-required non-fire-isolated stairways or pedestrian ramps subject to Specification 14\nS7C7\nSarking-type material\nS7C7\nAttachments to internal floors, walls and ceilings\nS7C7\nOther materials including insulation\nS7C7","g":"/ncc/s7c2","a19":["Spec C1.10: 2"]},{"c":"Table S7C3","t":"Critical radiant flux (CHF in kW/m2) of floor linings and floor coverings","p":"Specification 7 Fire hazard properties","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/7-fire-hazard-properties#_744a4185-36b6-4379-bed9-1f8546bb5d74","x":"Class of building | Building not fitted with a sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17 | Building fitted with a sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17 | Fire-isolated exits and fire control rooms\nClass 2, 3, 5, 6, 7, 8 or 9b, excluding Class 3 accommodation for the aged and Class 9b as specified below | 2.2 kW/m2 | 1.2 kW/m2 | 2.2 kW/m2\nClass 3 accommodation for the aged | 4.5 kW/m2 | 2.2 kW/m2 | 4.5 kW/m2\nClass 9a patient care areas | 4.5 kW/m2 | 2.2 kW/m2 | 4.5 kW/m2\nClass 9a areas other than patient care areas | 2.2 kW/m2 | 1.2 kW/m2 | 4.5 kW/m2\nClass 9b auditorium or audience seating area used mainly for indoor swimming or ice skating | 1.2 kW/m2 | 1.2 kW/m2 | 2.2 kW/m2\nClass 9b auditorium or audience seating area used mainly for other sports or multi-purpose functions | 2.2 kW/m2 | 1.2 kW/m2 | 2.2 kW/m2\nClass 9c resident use area | N/A | 2.2 kW/m2 | 4.5 kW/m2\nClass 9c areas other than resident use areas | N/A | 1.2 kW/m2 | 4.5 kW/m2","tb":"S7C3","g":"/ncc/table-s7c3"},{"c":"S7C3","t":"Floor linings and floor coverings","p":"Specification 7 Fire hazard properties","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/7-fire-hazard-properties#S7C3","x":"A floor lining or floor covering must have—\na critical radiant flux not less than that listed in Table S7C3; and\nin a building not protected by a sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17, a maximum smoke development rate of 750 percent-minutes; and\na group number complying with S7C6(b), for any portion of the floor covering that is continued more than 150 mm up a wall.\nTable S7C3 Critical radiant flux (CHF in kW/m2) of floor linings and floor coverings\nClass of building\nBuilding not fitted with a sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17\nBuilding fitted with a sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17\nFire-isolated exits and fire control rooms\nClass 2, 3, 5, 6, 7, 8 or 9b, excluding Class 3 accommodation for the aged and Class 9b as specified below\n2.2 kW/m2\n1.2 kW/m2\n2.2 kW/m2\nClass 3 accommodation for the aged\n4.5 kW/m2\n2.2 kW/m2\n4.5 kW/m2\nClass 9a patient care areas\n4.5 kW/m2\n2.2 kW/m2\n4.5 kW/m2\nClass 9a areas other than patient care areas\n2.2 kW/m2\n1.2 kW/m2\n4.5 kW/m2\nClass 9b auditorium or audience seating area used mainly for indoor swimming or ice skating\n1.2 kW/m2\n1.2 kW/m2\n2.2 kW/m2\nClass 9b auditorium or audience seating area used mainly for other sports or multi-purpose functions\n2.2 kW/m2\n1.2 kW/m2\n2.2 kW/m2\nClass 9c resident use area\nN/A\n2.2 kW/m2\n4.5 kW/m2\nClass 9c areas other than resident use areas\nN/A\n1.2 kW/m2\n4.5 kW/m2","g":"/ncc/s7c3","a19":["Spec C1.10: 3"]},{"c":"Table S7C4","t":"Wall and ceiling lining materials (material groups permitted)","p":"Specification 7 Fire hazard properties","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/7-fire-hazard-properties#_bb5cf7b0-1c26-403c-b5d9-b2510679b011","x":"Class of building | Fire-isolated exits and fire control rooms | Public corridors | Specific areas | Other areas\nClass 2 or 3, unsprinklered, excluding accommodation for the aged, people with disabilities and children | Walls: 1 | Walls: 1, 2 | Walls: 1, 2, 3 | Walls: 1, 2, 3\nCeilings: 1 | Ceilings: 1, 2 | Ceilings: 1, 2, 3 | Ceilings: 1, 2, 3\nClass 2 or 3, sprinklered, excluding accommodation for the aged, people with disabilities and children | Walls: 1 | Walls: 1, 2, 3 | Walls: 1, 2, 3 | Walls: 1, 2, 3\nCeilings: 1 | Ceilings: 1, 2, 3 | Ceilings: 1, 2, 3 | Ceilings: 1, 2, 3\nClass 3 or 9a, unsprinklered, accommodation for the aged, people with a disability, children and health-care buildings | Walls: 1 | Walls: 1 | Walls: 1, 2 | Walls: 1, 2, 3\nCeilings: 1 | Ceilings: 1 | Ceilings: 1, 2 | Ceilings: 1, 2, 3\nClass 3 or 9a, sprinklered, accommodation for the aged, people with a disability, children and health-care buildings | Walls: 1 | Walls: 1, 2 | Walls: 1, 2, 3 | Walls: 1, 2, 3\nCeilings: 1 | Ceilings: 1, 2 | Ceilings: 1, 2, 3 | Ceilings: 1, 2, 3\nClass 5, 6, 7, 8 or 9b schools, unsprinklered | Walls: 1 | Walls: 1, 2 | Walls: 1, 2, 3 | Walls: 1, 2, 3\nCeilings: 1 | Ceilings: 1, 2 | Ceilings: 1, 2 | Ceilings: 1, 2, 3\nClass 5, 6, 7, 8 or 9b schools, sprinklered | Walls: 1 | Walls: 1, 2, 3 | Walls: 1, 2, 3 | Walls: 1, 2, 3\nCeilings: 1 | Ceilings: 1, 2, 3 | Ceilings: 1, 2, 3 | Ceilings: 1 ,2, 3\nClass 9b other than schools, unsprinklered | Walls: 1 | Walls: 1 | Walls: 1, 2 | Walls: 1, 2, 3\nCeilings: 1 | Ceilings: 1 | Ceilings: 1, 2 | Ceilings: 1, 2, 3\nClass 9b other than schools, sprinklered | Walls: 1 | Walls: 1, 2 | Walls: 1, 2, 3 | Walls: 1, 2, 3\nCeilings: 1 | Ceilings: 1, 2 | Ceilings: 1, 2, 3 | Ceilings: 1, 2, 3\nClass 9c, sprinklered | Walls: 1 | Walls: 1, 2 | Walls: 1, 2, 3 | Walls: 1, 2, 3\nCeilings: 1 | Ceilings: 1, 2 | Ceilings: 1, 2, 3 | Ceilings: 1, 2, 3\nTable Notes\n”Sprinklered” means a building fitted with a sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17.\n”Specific areas” means within—\nfor Class 2 and 3 buildings, a sole-occupancy unit; and\nfor Class 5 buildings, open plan offices with a minimum floor dimension/floor to ceiling height ratio > 5; and\nfor Class 6 buildings, shops or other building with a minimum floor dimension/floor to ceiling height ratio > 5; and\nfor Class 9a health-care buildings, patient care areas; and\nfor Class 9b theatres and halls, etc, an auditorium; and\nfor Class 9b schools, a classroom; and\nfor Class 9c buildings, resident use area.","tb":"S7C4","g":"/ncc/table-s7c4"},{"c":"S7C4","t":"Wall and ceiling linings","p":"Specification 7 Fire hazard properties","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/7-fire-hazard-properties#S7C4","x":"(1) A wall or ceiling lining system must comply with the group number specified in Table S7C4 and for buildings not fitted with a sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17 have—\na smoke growth rate index not more than 100; or\nan average specific extinction area less than 250 m2/kg.\n(2) A group number of a wall or ceiling lining and the smoke growth rate index or average specific extinction area must be determined by an Accredited Testing Laboratory in accordance with AS 5637.1.\nNotes\nUntil adoption of the next edition of the NCC, determination need not be undertaken by an Accredited Testing Laboratory.\nTable S7C4 Wall and ceiling lining materials (material groups permitted)\nClass of building\nFire-isolated exits and fire control rooms\nPublic corridors\nSpecific areas\nOther areas\nClass 2 or 3, unsprinklered, excluding accommodation for the aged, people with disabilities and children\nWalls: 1\nWalls: 1, 2\nWalls: 1, 2, 3\nWalls: 1, 2, 3\nCeilings: 1\nCeilings: 1, 2\nCeilings: 1, 2, 3\nCeilings: 1, 2, 3\nClass 2 or 3, sprinklered, excluding accommodation for the aged, people with disabilities and children\nWalls: 1\nWalls: 1, 2, 3\nWalls: 1, 2, 3\nWalls: 1, 2, 3\nCeilings: 1\nCeilings: 1, 2, 3\nCeilings: 1, 2, 3\nCeilings: 1, 2, 3\nClass 3 or 9a, unsprinklered, accommodation for the aged, people with a disability, children and health-care buildings\nWalls: 1\nWalls: 1\nWalls: 1, 2\nWalls: 1, 2, 3\nCeilings: 1\nCeilings: 1\nCeilings: 1, 2\nCeilings: 1, 2, 3\nClass 3 or 9a, sprinklered, accommodation for the aged, people with a disability, children and health-care buildings\nWalls: 1\nWalls: 1, 2\nWalls: 1, 2, 3\nWalls: 1, 2, 3\nCeilings: 1\nCeilings: 1, 2\nCeilings: 1, 2, 3\nCeilings: 1, 2, 3\nClass 5, 6, 7, 8 or 9b schools, unsprinklered\nWalls: 1\nWalls: 1, 2\nWalls: 1, 2, 3\nWalls: 1, 2, 3\nCeilings: 1\nCeilings: 1, 2\nCeilings: 1, 2\nCeilings: 1, 2, 3\nClass 5, 6, 7, 8 or 9b schools, sprinklered\nWalls: 1\nWalls: 1, 2, 3\nWalls: 1, 2, 3\nWalls: 1, 2, 3\nCeilings: 1\nCeilings: 1, 2, 3\nCeilings: 1, 2, 3\nCeilings: 1 ,2, 3\nClass 9b other than schools, unsprinklered\nWalls: 1\nWalls: 1\nWalls: 1, 2\nWalls: 1, 2, 3\nCeilings: 1\nCeilings: 1\nCeilings: 1, 2\nCeilings: 1, 2, 3\nClass 9b other than schools, sprinklered\nWalls: 1\nWalls: 1, 2\nWalls: 1, 2, 3\nWalls: 1, 2, 3\nCeilings: 1\nCeilings: 1, 2\nCeilings: 1, 2, 3\nCeilings: 1, 2, 3\nClass 9c, sprinklered\nWalls: 1\nWalls: 1, 2\nWalls: 1, 2, 3\nWalls: 1, 2, 3\nCeilings: 1\nCeilings: 1, 2\nCeilings: 1, 2, 3\nCeilings: 1, 2, 3\nTable Notes\n”Sprinklered” means a building fitted with a sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17.\n”Specific areas” means within—\nfor Class 2 and 3 buildings, a sole-occupancy unit; and\nfor Class 5 buildings, open plan offices with a minimum floor dimension/floor to ceiling height ratio > 5; and\nfor Class 6 buildings, shops or other building with a minimum floor dimension/floor to ceiling height ratio > 5; and\nfor Class 9a health-care buildings, patient care areas; and\nfor Class 9b theatres and halls, etc, an auditorium; and\nfor Class 9b schools, a classroom; and\nfor Class 9c buildings, resident use area.","g":"/ncc/s7c4","a19":["Spec C1.10: 4"]},{"c":"S7C5","t":"Air-handling ductwork","p":"Specification 7 Fire hazard properties","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/7-fire-hazard-properties#S7C5","x":"Rigid and flexible ductwork in a Class 2 to 9 building must comply with the fire hazard properties set out in AS 4254.1 and AS 4254.2.","g":"/ncc/s7c5","a19":["Spec C1.10: 5"]},{"c":"S7C6","t":"Lift cars","p":"Specification 7 Fire hazard properties","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/7-fire-hazard-properties#S7C6","x":"Materials used as—\nfloor linings and floor coverings must have a critical radiant flux not less than 2.2; and\nwall and ceiling linings must be a Group 1 material or a Group 2 material in accordance with AS 5637.1.","g":"/ncc/s7c6","a19":["Spec C1.10: 6"]},{"c":"Table S7C7","t":"Other materials","p":"Specification 7 Fire hazard properties","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/7-fire-hazard-properties#_28468033-eb96-4bfc-ab97-19dc91a68b28","x":"Material or assembly location | Flammability Index | Spread-of-Flame Index | Smoke-Developed Index\nFire control rooms subject to Specification 19 and fire-isolated exits, other than a sarking-type material used in a ceiling or used as an attachment or part of an attachment to a building element. Note 1 | N/A | 0 | 2\nClass 9b buildings used as a theatre, public hall or the like: Any part of fixed seating in the audience area or auditorium. | N/A | 0 | 5\nClass 9b buildings used as a theatre, public hall or the like: A proscenium curtain required by Specification 32. | N/A | 0 | 3\nEscalators, moving walkways or non-required non fire-isolated stairway or pedestrian ramps subject to Specification 14. | N/A | 0 | 5\nSarking-type materials: In a fire control room subject to Specification 19 or a fire-isolated exit or fire control room used in the form of an exposed wall or ceiling. | 0 | N/A | N/A\nSarking-type materials: In other locations. Note 2 | 5 | N/A | N/A\nOther materials or locations and insulation materials other than sarking-type material. Notes 2 and 3 | N/A | 9 | 8 if the Spread-of-Flame Index is more than 5\nTable Notes\nIn a fire control room or fire-isolated stairway, a material used as an attachment or part of an attachment to a building element must, if combustible, be attached directly to a non-combustible substrate and not exceed 1 mm finished thickness.\nA material, other than one located within a fire-isolated exit or fire control room, may be covered on all faces by concrete or masonry not less than 50 mm thick, as an alternative to meeting the specified indices.\nIn the case of a composite member or assembly, the member or assembly must be constructed so that when assembled as proposed in a building—\nany material which does not comply with this table is protected on all sides and edges from exposure to the air; and\nthe member or assembly, when tested in accordance with Specification 3, has Spread-of-Flame Index and Smoke-Developed Index not exceeding those prescribed in this table; and\nthe member or assembly retains the protection in position so that it prevents ignition of the material and continues to screen it from access to free air for a period of not less than 10 minutes.","tb":"S7C7","g":"/ncc/table-s7c7"},{"c":"S7C7","t":"Other materials","p":"Specification 7 Fire hazard properties","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/7-fire-hazard-properties#S7C7","x":"Materials and assemblies not included in S7C3, S7C4, S7C5 or S7C6 must not exceed the indices set out in Table S7C7.\nTable S7C7 Other materials\nMaterial or assembly location\nFlammability Index\nSpread-of-Flame Index\nSmoke-Developed Index\nFire control rooms subject to Specification 19 and fire-isolated exits, other than a sarking-type material used in a ceiling or used as an attachment or part of an attachment to a building element. Note 1\nN/A\n0\n2\nClass 9b buildings used as a theatre, public hall or the like: Any part of fixed seating in the audience area or auditorium.\nN/A\n0\n5\nClass 9b buildings used as a theatre, public hall or the like:\nA proscenium curtain required by Specification 32.\nN/A\n0\n3\nEscalators, moving walkways or non-required non fire-isolated stairway or pedestrian ramps subject to Specification 14.\nN/A\n0\n5\nSarking-type materials: In a fire control room subject to Specification 19 or a fire-isolated exit or fire control room used in the form of an exposed wall or ceiling.\n0\nN/A\nN/A\nSarking-type materials: In other locations. Note 2\n5\nN/A\nN/A\nOther materials or locations and insulation materials other than sarking-type material. Notes 2 and 3\nN/A\n9\n8 if the Spread-of-Flame Index is more than 5\nTable Notes\nIn a fire control room or fire-isolated stairway, a material used as an attachment or part of an attachment to a building element must, if combustible, be attached directly to a non-combustible substrate and not exceed 1 mm finished thickness.\nA material, other than one located within a fire-isolated exit or fire control room, may be covered on all faces by concrete or masonry not less than 50 mm thick, as an alternative to meeting the specified indices.\nIn the case of a composite member or assembly, the member or assembly must be constructed so that when assembled as proposed in a building—\nany material which does not comply with this table is protected on all sides and edges from exposure to the air; and\nthe member or assembly, when tested in accordance with Specification 3, has Spread-of-Flame Index and Smoke-Developed Index not exceeding those prescribed in this table; and\nthe member or assembly retains the protection in position so that it prevents ignition of the material and continues to screen it from access to free air for a period of not less than 10 minutes.","g":"/ncc/s7c7","a19":["Spec C1.10: 7"]},{"c":"S8C1","t":"Scope","p":"Specification 8 Performance of external walls in fire","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/8-performance-external-walls-fire#S8C1","x":"This Specification contains measures to minimise, in the event of fire, the likelihood of external walls covered by S8C2 collapsing outwards as complete panels and the likelihood of panels separating from supporting members.","g":"/ncc/s8c1","a19":["Spec C1.11: 1"]},{"c":"S8C2","t":"Application","p":"Specification 8 Performance of external walls in fire","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/8-performance-external-walls-fire#S8C2","x":"This Specification applies to buildings having a rise in storeys of not more than 2 with concrete external walls that could collapse as complete panels (e.g. tilt-up and precast concrete) which—\nconsist of either single or multiple panels attached by steel connections to lateral supporting members; and\ndepend on those connections to resist outward movement of the panels relative to the supporting members; and\nhave height to thickness ratio not greater than 50.","g":"/ncc/s8c2","a19":["Spec C1.11: 2"]},{"c":"S8C3","t":"General requirements for external wall panels","p":"Specification 8 Performance of external walls in fire","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/8-performance-external-walls-fire#S8C3","x":"(1) Cast-in inserts and fixings must be anchored into the panel with welded bars or be fixed to the panel reinforcement.\n(2) Cast-in inserts for top connections and fixings acting together must be able to resist an ultimate load of two times the larger of the forces required to develop—\nthe ultimate bending moment capacity of the panel at its base; or\nthe overturning moment at the base of the panel arising from an outwards lateral displacement at the top of the panel equal to one tenth of the panel height.\n(3) Top connections of the panel exposed to fire, such as clips and drilled-in inserts, acting together must be able to resist an ultimate load of six times the larger of the forces required to develop the moment specified in (2)(a) or (b).\n(4) Lateral supporting members and their connections must be designed to resist the connection forces specified in (2) and (3) and in the case of an eaves tie member the force in the member must be determined assuming that it deforms in a manner compatible with the lateral displacement of the wall panels, and that it acts in tension only.\n(5) External wall panels that span vertically must have at least two upper connections per panel to the supporting member, except that where a number of panels are designed to act as one unit, (e.g. tongue and groove hollow-core panels), only two upper connections are required for each unit.\n(6) External wall panels that span horizontally between columns must have at least two connections at each column.\n(7) Connections providing lateral support to a panel must be designed to remain engaged to the supported panel both before and during a fire.\nNotes\nThe increased forces specified by the multiplier of two or six in (2) and (3) above are to take account of the lower strength of the connections and members at the higher than ambient temperatures expected in a fire.","g":"/ncc/s8c3","a19":["Spec C1.11: 3"]},{"c":"S8C4","t":"Additional requirements for vertically spanning external wall panels adjacent to columns","p":"Specification 8 Performance of external walls in fire","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/8-performance-external-walls-fire#S8C4","x":"(1) Where vertically spanning external wall panels are located adjacent to columns, connections to the panels must be located and/or detailed to minimise forces that may develop between the panels and columns arising from the restraint of differential displacement.\n(2) The requirements of (1) are satisfied by—\ndetailing the connections and/or the supporting member to sustain a relative outward displacement of (d) between the panels and columns at the connection height where d(m) is calculated as—\nthe square of the connection height (m) divided by one hundred and twenty-five, when the connection height is less than 5 m; or\nthe connection height (m) divided by twenty-five, when the connection height (m) is greater than or equal to 5 m; or\nin situations where an eaves tie member is used to provide lateral support to external wall panels, the tie member is connected to the panels no closer than a distance (s) from the column where s(m) is taken as one quarter of the panel height (m).","g":"/ncc/s8c4","a19":["Spec C1.11: 4"]},{"c":"S9C1","t":"Scope","p":"Specification 9 Cavity barriers for fire-protected timber","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/9-cavity-barriers-fire-protected-timber#S9C1","x":"This Specification sets out requirements for cavity barriers in fire-protected timber construction.","g":"/ncc/s9c1","a19":["Spec C1.13: 1"]},{"c":"Table S9C2","t":"Cavity barrier requirements","p":"Specification 9 Cavity barriers for fire-protected timber","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/9-cavity-barriers-fire-protected-timber#_234a9e91-f87b-46a0-a6da-6a152d4cfd3d","x":"System required FRL | –/60/60 or –/90/90 | –/120/120, –/180/180 or –/240/240\nCavity barrier required FRL | –/45/45 | –/60/60\nTimber, required minimum thickness | 45 mm | 60 mm\nMineral wool, required minimum thickness | 45 mm | 60 mm\nTable Notes\nMinimum thicknesses are to be measured in the direction of heat flow.","tb":"S9C2","g":"/ncc/table-s9c2"},{"c":"S9C2","t":"Requirements","p":"Specification 9 Cavity barriers for fire-protected timber","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/9-cavity-barriers-fire-protected-timber#S9C2","x":"(1) Cavity barriers must be provided in the following locations where fire-protected timber is used in any of the listed elements:\nAt concealed cavities adjacent to junctions between fire-resisting floor/ceiling assemblies and fire-resisting walls.\nAt concealed cavities adjacent to junctions between fire-resisting floor/ceiling assemblies and fire-resisting or non-combustible external walls.\nAt concealed cavities adjacent to junctions between fire-resisting walls and fire-resisting or non-combustible external walls.\nAround the perimeter of door and window openings in fire-resisting construction.\n(2) Cavity barriers must be installed so they are tight fitting and are able to withstand thermal expansion and structural movement without the loss of seal against fire and smoke.\n(3) In addition to cavity barriers required by (1), horizontal and vertical cavity barriers are to be provided to wall cavities within, around or adjacent to fire-protected timber elements as follows:\nHorizontal cavity barriers — at not more than 5 m centres.\nVertical cavity barriers — at not more than 10 m centres.\n(4) Cavity barriers must—\nachieve the performance specified in Table S9C2 based on the highest FRL of the elements they are mounted within or seal against; or\nconsist of—\ntimber with the minimum thickness specified in Table S9C2; or\npolythene-sleeved mineral wool or mineral wool slabs or strips placed under compression to achieve the minimum thickness specified in Table S9C2.\n(5) Cavity barriers provided around openings may be formed by the window or door frame if—\nthe frame is constructed of steel or timber with the minimum thickness specified in Table S9C2 for timber; and\nthe frame is tightly fitted to rigid construction and mechanically fixed in position.\n(6) The FRL of cavity barriers in fire-protected timber construction must be determined in accordance with Specifications 1 and 2 applying the criteria for control joint systems specified in Section 10 of AS 1530.4 with the cavity barrier system fitted within an opening between timber members exposed directly to the furnace heating conditions.\n(7) Notwithstanding anything to the contrary in Specifications 1 and 2 or AS 1530.4, the test results from (6) may be used when the fire-protected timber is constructed from timber having a nominal density at least equal to the tested timber.\nTable S9C2 Cavity barrier requirements\nSystem required FRL\n–/60/60 or –/90/90\n–/120/120, –/180/180 or –/240/240\nCavity barrier required FRL\n–/45/45\n–/60/60\nTimber, required minimum thickness\n45 mm\n60 mm\nMineral wool, required minimum thickness\n45 mm\n60 mm\nTable Notes\nMinimum thicknesses are to be measured in the direction of heat flow.","g":"/ncc/s9c2","a19":["Spec C1.13: 2"]},{"c":"C1O1","t":"Objective","p":"Part C1 Fire resistance","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c1-fire-resistance#C1O1","x":"The Objective of Parts C1, C2, C3 and C4 is to—\nsafeguard people from illness or injury due to a fire in a building; and\nsafeguard occupants from illness or injury while evacuating a building during a fire; and\nfacilitate the activities of emergency services personnel; and\navoid the spread of fire between buildings; and\nprotect other property from physical damage caused by structural failure of a building as a result of fire","g":"/ncc/c1o1","a19":["CO1"]},{"c":"C1F1","t":"Structural stability during a fire","p":"Part C1 Fire resistance","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c1-fire-resistance#C1F1","x":"A building is to be constructed to maintain structural stability during fire to—\nallow occupants time to evacuate safely; and\nallow for fire brigade intervention; and\navoid damage to other property.","g":"/ncc/c1f1","a19":["CF1"]},{"c":"C1F2","t":"Prevention of fire spread","p":"Part C1 Fire resistance","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c1-fire-resistance#C1F2","x":"A building is to be provided with safeguards to prevent fire spread—\nso that occupants have time to evacuate safely without being overcome by the effects of fire; and\nto allow for fire brigade intervention; and\nto sole-occupancy units providing sleeping accommodation; and\nto adjoining fire compartments; and\nbetween buildings.\nApplications\nC1F2(c) only applies to a Class 2 or 3 building or Class 4 part of a building.","g":"/ncc/c1f2","a19":["CF2"]},{"c":"C1P1","t":"Structural stability during a fire","p":"Part C1 Fire resistance","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c1-fire-resistance#C1P1","x":"A building must have elements which will, to the degree necessary, maintain structural stability during a fire appropriate to—\nthe function or use of the building; and\nthe fire load; and\nthe potential fire intensity; and\nthe fire hazard; and\nthe height of the building; and\nits proximity to other property; and\nany active fire safety systems installed in the building; and\nthe size of any fire compartment; and\nfire brigade intervention; and\nother elements they support; and\nthe evacuation time.","g":"/ncc/c1p1","a19":["CP1"]},{"c":"C1P2","t":"Spread of fire","p":"Part C1 Fire resistance","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c1-fire-resistance#C1P2","x":"(1) A building must have elements which will, to the degree necessary, avoid the spread of fire—\nto exits; and\nto sole-occupancy units and public corridors; and\nbetween buildings; and\nin a building.\n(2) Avoidance of the spread of fire referred to in (1) must be appropriate to—\nthe function or use of the building; and\nthe fire load; and\nthe potential fire intensity; and\nthe fire hazard; and\nthe number of storeys in the building; and\nits proximity to other property; and\nany active fire safety systems installed in the building; and\nthe size of any fire compartment; and\nfire brigade intervention; and\nother elements they support; and\nthe evacuation time.\nApplications\nC1P2(1)(b) only applies to a Class 2 or 3 building or Class 4 part of a building.","g":"/ncc/c1p2","a19":["CP2"]},{"c":"C1P3","t":"Spread of fire and smoke in health and residential care buildings","p":"Part C1 Fire resistance","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c1-fire-resistance#C1P3","x":"A building must be protected from the spread of fire and smoke to allow sufficient time for the orderly evacuation of the building in an emergency.\nApplications\nC1P3 only applies to—\na patient care area of a Class 9a health-care building; and\na Class 9c building.","g":"/ncc/c1p3","a19":["CP3"]},{"c":"C1P4","t":"Safe conditions for evacuation","p":"Part C1 Fire resistance","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c1-fire-resistance#C1P4","x":"To maintain tenable conditions during occupant evacuation, a material and an assembly must, to the degree necessary, resist the spread of fire and limit the generation of smoke and heat, and any toxic gases likely to be produced, appropriate to—\nthe evacuation time; and\nthe number, mobility and other characteristics of occupants; and\nthe function or use of the building; and\nany active fire safety systems installed in the building.\nApplications\nC1P4 applies to linings, materials and assemblies in a Class 2 to 9 building.","g":"/ncc/c1p4","a19":["CP4"]},{"c":"C1P5","t":"Behaviour of concrete external walls in a fire","p":"Part C1 Fire resistance","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c1-fire-resistance#C1P5","x":"A concrete external wall that could collapse as a complete panel (e.g. tilt-up and pre-cast concrete) must be designed so that in the event of fire within the building the likelihood of outward collapse is avoided.\nLimitations\nC1P5 does not apply to a building having more than two storeys above ground level.","g":"/ncc/c1p5","a19":["CP5"]},{"c":"C1P6","t":"Fire protection of service equipment","p":"Part C1 Fire resistance","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c1-fire-resistance#C1P6","x":"A building must have elements, which will, to the degree necessary, avoid the spread of fire from service equipment having—\na high fire hazard; or\na potential for explosion resulting from a high fire hazard.","g":"/ncc/c1p6","a19":["CP6"]},{"c":"C1P7","t":"Fire protection of emergency equipment","p":"Part C1 Fire resistance","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c1-fire-resistance#C1P7","x":"A building must have elements, which will, to the degree necessary, avoid the spread of fire so that emergency equipment provided in a building will continue to operate for a period of time necessary to ensure that the intended function of the equipment is maintained during a fire.","g":"/ncc/c1p7","a19":["CP7"]},{"c":"C1P8","t":"Fire protection of openings and penetrations","p":"Part C1 Fire resistance","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c1-fire-resistance#C1P8","x":"Any building element provided to resist the spread of fire must be protected, to the degree necessary, so that an adequate level of performance is maintained—\nwhere openings, construction joints and the like occur; and\nwhere penetrations occur for building services.","g":"/ncc/c1p8","a19":["CP8"]},{"c":"C1P9","t":"Fire brigade access","p":"Part C1 Fire resistance","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c1-fire-resistance#C1P9","x":"Access must be provided to and around a building, to the degree necessary, for fire brigade vehicles and personnel to facilitate fire brigade intervention appropriate to—\nthe function or use of the building; and\nthe fire load; and\nthe potential fire intensity; and\nthe fire hazard; and\nany active fire safety systems installed in the building; and\nthe size of any fire compartment.","g":"/ncc/c1p9","a19":["CP9"]},{"c":"Table C1V1","t":"Fire spread between buildings on adjoining allotments","p":"Part C1 Fire resistance","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c1-fire-resistance#_a5d78775-6c85-468a-9050-3afa107f9cee","x":"Column 1 (Location) | Column 2 (Heat flux (kW/m2))\nOn boundary | 80\n1 m from boundary | 40\n3 m from boundary | 20\n6 m from boundary | 10","tb":"C1V1","g":"/ncc/table-c1v1"},{"c":"C1V1","t":"Fire spread between buildings on adjoining allotments","p":"Part C1 Fire resistance","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c1-fire-resistance#C1V1","x":"Compliance with C1P2(1)(c) to avoid the spread of fire between buildings on adjoining allotments is verified when it is calculated that—\na building will not cause heat flux in excess of those set out in Column 2 of Table C1V1 at the location on an adjoining property set out in Column 1 of Table C1V1; and\nwhen located at the distances from the allotment boundary set out in Column 1 of Table C1V1, a building is capable of withstanding the heat flux set out in Column 2 of Table C1V1 without ignition.\nTable C1V1 Fire spread between buildings on adjoining allotments\nColumn 1 (Location)\nColumn 2 (Heat flux (kW/m2))\nOn boundary\n80\n1 m from boundary\n40\n3 m from boundary\n20\n6 m from boundary\n10","g":"/ncc/c1v1","a19":["CV1"]},{"c":"Table C1V2","t":"Fire spread between buildings on the same allotment","p":"Part C1 Fire resistance","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c1-fire-resistance#_40e7623e-1ce0-4b7f-aee5-ca831e86dbc1","x":"Column 1 (Distance between buildings on the same allotment (m)) | Column 2 (Heat flux (kW/m2))\n0 | 80\n2 | 40\n6 | 20\n12 | 10","tb":"C1V2","g":"/ncc/table-c1v2"},{"c":"C1V2","t":"Fire spread between buildings on the same allotment","p":"Part C1 Fire resistance","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c1-fire-resistance#C1V2","x":"Compliance with C1P2(1)(c) to avoid the spread of fire between buildings on the same allotment is verified when, for the distances between buildings set out in Column 1 of Table C1V2, it is calculated that a building—\nis capable of withstanding the heat flux set out in Column 2 of Table C1V2 without ignition; and\nwill not cause heat flux in excess of those set out in Column 2 of Table C1V2.\nTable C1V2 Fire spread between buildings on the same allotment\nColumn 1 (Distance between buildings on the same allotment (m))\nColumn 2 (Heat flux (kW/m2))\n0\n80\n2\n40\n6\n20\n12\n10","g":"/ncc/c1v2","a19":["CV2"]},{"c":"C1V3","t":"Fire spread via external walls","p":"Part C1 Fire resistance","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c1-fire-resistance#C1V3","x":"Compliance with C1P2 to avoid the spread of fire via the external wall of a building is verified when—\ncompliance with C1P2(1)(c) to avoid the spread of fire between buildings, where applicable, is verified in accordance with C1V1 or C1V2, as appropriate; and\nthe external wall system—\nhas been tested for external wall (EW) performance by an Accredited Testing Laboratory in accordance with AS 5113; and\nhas achieved the classification EW; and\nif containing a cavity, incorporates cavity barriers and these cavity barriers have been included in the test performed under (i) at the perimeter of each floor; and\nin a building of Type A construction, the building is protected throughout by a sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17 and has—\nsprinkler protection to balconies, patios and terraces, and where overhead sprinkler coverage is not achieved alongside the external wall, sidewall sprinkler heads are provided at the external wall for the extent of the balcony, patio or terrace where overhead sprinkler coverage is not achieved; and\nfor a building with an effective height more than 25 m—\nmonitored stop valves provided at each floor level arranged to allow the isolation of the floor level containing the stop valve while maintaining protection to the remainder of the building; and\nthe sprinkler system being capable of providing sufficient flow to serve the design area required by AS 2118.1 for the relevant hazard class on each floor level plus the design area required by AS 2118.1 for the floor level above, except where the former level is either the floor level below the uppermost roof, or any floor level that is wholly below ground; and\nin a building of Type B construction, the building is—\na Class 5, 6, 7 or 8 building or Class 4 part of a building; or\na Class 2, 3 or 9 building that—\nis protected throughout by a sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17; or\nhas any openings in external walls separated by a slab or other horizontal construction complying with C3D7(1)(d) as if the building were of Type A construction.\nNotes\nUntil adoption of the next edition of the NCC, EW performance testing need not be undertaken by an Accredited Testing Laboratory.","g":"/ncc/c1v3","a19":["CV3"]},{"c":"C1V4","t":"Fire Safety Verification Method","p":"Part C1 Fire resistance","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c1-fire-resistance#C1V4","x":"(1) Compliance with C1P1, C1P2, C1P3, C1P4, C1P5, C1P6, C1P7, C1P8 and C1P9 is verified when a building is designed in accordance with—\nthe requirements of (2), (3), (4), (5) and (6); and\nthe Fire Safety Verification Method Standard.\n(2) Performance-based design brief (PBDB):\nWhen using this Verification Method, the fire safety engineer must undertake a performance-based design brief (PBDB) that must—\ninvolve all stakeholders relevant to the building design; and\noutline the fire strategy to be adopted.\nWhile full agreement on all aspects of the PBDB is the preferred outcome, it is acknowledged that in some instances this may not be possible to obtain.\nIn the event that full agreement cannot be achieved through the PBDB, dissenting views must be appropriately recorded and carried throughout the process and considered as part of the due processes of the appropriate authority when determining compliance and providing approval.\nConsideration of whether a peer review (by an independent fire safety engineer) of some or all of the proposed Performance Solutions and the supporting analysis is required or not, must be undertaken at this PBDB stage.\n(3) Fire strategy:\nThe PBDB must cover the fire safety strategy for the building, outlining the philosophy and approach that will be adopted to achieve the required level of performance.\nThe fire safety strategy must pay particular attention to the evacuation strategy to be used and the management regimes necessary.\n(4) Stakeholder involvement:\nThe PBDB must be developed collaboratively by the relevant stakeholders in the particular project.\nThe following parties must be involved:\nClient or client’s representative (such as project manager).\nFire engineer.\nArchitect or designer.\nVarious specialist consultants.\nFire service (public or private).\nAppropriate authority (Authority Having Jurisdiction – subject to state/territory legislation).\nTenants or tenants representative for the proposed building (if available)\nBuilding operations management (if available).\nConducting a simple stakeholder analysis can be used to determine who must be involved in the PBDB process.\nThis analysis must identify stakeholders with a high level of interest in the design process, and/or likely to be affected by the consequences of a fire should it occur in the building.\n(5) Required level of safety:\nGiven the absence of specific safety targets in the NCC and the qualitative nature of the NCC fire safety Performance Requirements, for this Verification Method to ensure the level of safety expected, the proposed building design must be at least equivalent to the relevant Deemed-to-Satisfy Provisions.\nAs the NCC Deemed-to-Satisfy Provisions evolved originally from State and Territory regulations and are regularly updated to reflect technical advances and experience they are commonly accepted as providing an acceptable benchmark.\nIt is accepted that the NCC Deemed-to-Satisfy Provisions reflect societal expectations in terms of fire safety, which address individual risk, societal risk and the robustness in the design by adopting a defence in depth approach.\nIn the majority of design scenarios the Verification Method requires a demonstration that the proposed level of safety is at least equivalent to the Deemed-to-Satisfy Provisions.\nIn relation to the required level of safety, the PBDB process must—\nidentify the relevant Deemed-to-Satisfy Provisions to be used in the equivalency process to determine whether the relevant Performance Requirements have been met; and\nconsider the specific size, complexity and use of the building with regards to the Deemed-to-Satisfy Provisions to be used in the equivalency process; and\nconsider the specific occupant profile of the building, paying particular attention to occupants with a disability and the vulnerable, in regards to the Deemed-to-Satisfy Provisions to be used in the equivalency process.\n(6) Final report: Once the analysis of all relevant design scenarios for all the required Performance Solutions has been completed, the fire safety engineer must prepare a final report that includes the following:\nThe agreed PBDB.\nAll modelling and analysis.\nAnalysis required to demonstrate that the proposed building provides a level of safety at least equivalent to the relevant Deemed-to-Satisfy Provisions.\nAny other information required to clearly demonstrate that the building and its fire safety system satisfies the relevant Performance Requirements as set out in the Fire Safety Verification Method Standard.","g":"/ncc/c1v4","a19":["CV4","Sch. 7 - cl. 1.3"]},{"c":"C2D1","t":"Deemed-to-Satisfy Provisions","p":"Part C2 Fire resistance and stability","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c2-fire-resistance-and-stability#C2D1","x":"(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements C1P1 to C1P9 are satisfied by complying with—\nC2D2 to C2D15, C3D2 to C3D15 and C4D2 to C4D17; and\nin a building containing an atrium, Part G3; and\nfor a building containing an occupiable outdoor area, Part G6; and\nfor additional requirements for Class 9b buildings, Part I1; and\nfor farm sheds, Part I3.\n(2) Where a Performance Solution is proposed, the relevant Performance Requirements must be determined in accordance with A2G2(3) and A2G4(3) as applicable.","g":"/ncc/c2d1","a19":["C1.0"]},{"c":"Table C2D2","t":"Type of construction required","p":"Part C2 Fire resistance and stability","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c2-fire-resistance-and-stability#_277b7bae-fe26-4d08-893c-0d9d7bde479d","x":"Rise in storeys | Class of building 2, 3, 9 | Class of building 5, 6, 7, 8\n4 or more | A | A\n3 | A | B\n2 | B | C\n1 | C | C","tb":"C2D2","g":"/ncc/table-c2d2"},{"c":"C2D2","t":"Type of construction required","p":"Part C2 Fire resistance and stability","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c2-fire-resistance-and-stability#C2D2","x":"(1) The minimum Type of fire-resisting construction of a building must be determined in accordance with Table C2D2, except as allowed for—\ncertain Class 2, 3 or 9c buildings, in C2D6; and\na Class 4 part of a building located on the top storey, in C2D4(2); and\nopen spectator stands and indoor sports stadiums, in C2D8.\n(2) Each building element must comply with Specification 5 as applicable.\nTable C2D2 Type of construction required\nRise in storeys\nClass of building 2, 3, 9\nClass of building 5, 6, 7, 8\n4 or more\nA\nA\n3\nA\nB\n2\nB\nC\n1\nC\nC","g":"/ncc/c2d2","a19":["C1.1"]},{"c":"C2D3","t":"Calculation of rise in storeys","p":"Part C2 Fire resistance and stability","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c2-fire-resistance-and-stability#C2D3","x":"(1) The rise in storeys is the sum of the greatest number of storeys at any part of the external walls of the building and any storeys within the roof space—\nabove the finished ground next to that part; or\nif part of the external wall is on the boundary of the allotment, above the natural ground level at the relevant part of the boundary.\n(2) A storey is not counted if—\nit is situated at the top of the building and contains only heating, ventilating or lift equipment, water tanks, or similar service units or equipment; or\nit is situated partly below the finished ground and the underside of the ceiling is not more than 1 m above the average finished level of the ground at the external wall, or if the external wall is more than 12 m long, the average for the 12 m part where the ground is lowest.\n(3) In a Class 7 or 8 building, a storey that has an average internal height of more than 6 m is counted as—\none storey if it is the only storey above the ground; or\n2 storeys in any other case.\n(4) For the purposes of calculating the rise in storeys of a building—\na mezzanine is regarded as a storey in that part of the building in which it is situated if its floor area is more than 200 m2 or more than ⅓ of the floor area of the room, whichever is the lesser; and\ntwo or more mezzanines are regarded as a storey in that part of the building in which they are situated if they are at or near the same level and have an aggregate floor area more than 200 m2 or more than ⅓ of the floor area of the room, whichever is the lesser.","g":"/ncc/c2d3","a19":["C1.2"]},{"c":"C2D4","t":"Buildings of multiple classification","p":"Part C2 Fire resistance and stability","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c2-fire-resistance-and-stability#C2D4","x":"(1) In a building of multiple classifications, the Type of construction required for the building is the most fire-resisting Type resulting from the application of Table C2D2 on the basis that the classification applying to the top storey applies to all storeys.\n(2) In a building containing a Class 4 part on the top storey, for the purpose of (1), the classification applying to the top storey must be—\nwhen the Class 4 part occupies the whole of the top storey, the classification applicable to the next highest storey; or\nwhen the Class 4 part occupies part of the top storey, the classification applicable to the adjacent part.","g":"/ncc/c2d4","a19":["C1.3"]},{"c":"C2D5","t":"Mixed types of construction","p":"Part C2 Fire resistance and stability","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c2-fire-resistance-and-stability#C2D5","x":"A building may be of mixed Types of construction where it is separated in accordance with C3D8 and the Type of construction is determined in accordance with C2D2 or C2D4.","g":"/ncc/c2d5","a19":["C1.4"]},{"c":"C2D6","t":"Two storey Class 2, 3 or 9c buildings","p":"Part C2 Fire resistance and stability","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c2-fire-resistance-and-stability#C2D6","x":"A building having a rise in storeys of 2 may be of Type C construction if—\nit is a Class 2 or 3 building or a mixture of these classes and each sole-occupancy unit has—\naccess to at least 2 exits; or\nits own direct access to a road or open space; or\nit is a Class 9c building protected throughout with a sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17 and complies with the maximum compartment size specified in Table C3D3 for Type C construction.","g":"/ncc/c2d6","a19":["C1.5"]},{"c":"C2D7","t":"Class 4 parts of buildings","p":"Part C2 Fire resistance and stability","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c2-fire-resistance-and-stability#C2D7","x":"For the Type of construction required by C2D4, a Class 4 part of a building requires the same FRL for building elements and the same construction separating the Class 4 part from the remainder of the building as a Class 2 part in the same Type of construction.","g":"/ncc/c2d7","a19":["C1.6"]},{"c":"C2D8","t":"Open spectator stands and indoor sports stadiums","p":"Part C2 Fire resistance and stability","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c2-fire-resistance-and-stability#C2D8","x":"(1) An open spectator stand or indoor sports stadium may be of Type C construction and need not comply with the other provisions of this Part if it contains not more than one tier of seating, is of non-combustible construction, and has only changing rooms, sanitary facilities or the like below the tiered seating.\n(2) In (1), one tier of seating means numerous rows of tiered seating incorporating cross-overs but within one viewing level.","g":"/ncc/c2d8","a19":["C1.7"]},{"c":"C2D9","t":"Lightweight construction","p":"Part C2 Fire resistance and stability","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c2-fire-resistance-and-stability#C2D9","x":"(1) Lightweight construction must comply with Specification 6 if it is used in a wall system—\nthat is required to have an FRL; or\nfor a lift shaft, stair shaft or service shaft or an external wall bounding a public corridor including a non fire-isolated passageway or non fire-isolated ramp, in a spectator stand, sports stadium, cinema or theatre, railway station, bus station or airport terminal.\n(2) If lightweight construction is used for the fire-resisting covering of a steel column or the like, and if—\nthe covering is not in continuous contact with the column, then the void must be filled solid, to a height of not less than 1.2 m above the floor to prevent indenting; and\nthe column is liable to be damaged from the movement of vehicles, materials or equipment, then the covering must be protected by steel or other suitable material.","g":"/ncc/c2d9","a19":["C1.8"]},{"c":"C2D10","t":"Non-combustible building elements","p":"Part C2 Fire resistance and stability","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c2-fire-resistance-and-stability#C2D10","x":"(1) In a building required to be of Type A or B construction, the following building elements and their components must be non-combustible:\nExternal walls and common walls, including all components incorporated in them including the facade covering, framing and insulation.\nThe flooring and floor framing of lift pits.\nNon-load bearing internal walls where they are required to be fire-resisting.\n(2) A shaft, being a lift, ventilating, pipe, garbage, or similar shaft that is not for the discharge of hot products of combustion, that is non-load bearing, must be of non-combustible construction in—\na building required to be of Type A construction; and\na building required to be of Type B construction, subject to C3D11, in—\na Class 2, 3 or 9 building; and\na Class 5, 6, 7 or 8 building if the shaft connects more than 2 storeys.\n(3) A load bearing internal wall and a load bearing fire wall, including those that are part of a load bearing shaft, must comply with Specification 5.\n(4) The requirements of (1) and (2) do not apply to the following:\nGaskets.\nCaulking.\nSealants.\nTermite management systems.\nGlass, including laminated glass, and associated adhesives, including tapes.\nThermal breaks associated with—\nglazing systems; or\nexternal wall systems, where the thermal breaks—\nare no larger than necessary to achieve thermal objectives; and\ndo not extend beyond one storey; and\ndo not extend beyond one fire compartment.\nDamp-proof courses.\nCompressible fillers and backing materials, including those associated with articulation joints, closing gaps not wider than 50 mm.\nIsolated—\nconstruction packers and shims; or\nblocking for fixing fixtures; or\nfixings, including fixing accessories; or\nacoustic mounts.\nWaterproofing materials applied to the external face, used below ground level and up to 250 mm above ground level.\nJoint trims and joint reinforcing tape and mesh of a width not greater than 50 mm.\nWeather sealing materials, applied to gaps not wider than 50 mm, used within and between concrete elements.\nWall ties and other masonry components complying with AS/NZS 2699 Part 1 and Part 3 as appropriate, and associated with masonry wall construction.\nReinforcing bars and associated minor elements that are wholly or predominately encased in concrete or grout.\nA paint, lacquer or a similar finish or coating.\nAdhesives, including tapes, associated with stiffeners for cladding systems.\nFire-protective materials and components required for the protection of penetrations.\n(5) The following materials, when entirely composed of itself, are non-combustible and may be used wherever a non-combustible material is required:\nConcrete.\nSteel, including metallic coated steel.\nMasonry, including mortar.\nAluminium, including aluminium alloy.\nAutoclaved aerated concrete, including mortar.\nIron.\nTerracotta.\nPorcelain.\nCeramic.\nNatural stone.\nCopper.\nZinc.\nLead.\nBronze.\nBrass.\n(6) The following materials may be used wherever a non-combustible material is required:\nPlasterboard.\nPerforated gypsum lath with a normal paper finish.\nFibrous-plaster sheet.\nFibre-reinforced cement sheeting.\nPre-finished metal sheeting having a combustible surface finish not exceeding 1 mm thickness and where the Spread-of-Flame Index of the product is not greater than 0.\nSarking-type materials that do not exceed 1 mm in thickness and have a Flammability Index not greater than 5.\nBonded laminated materials where—\neach lamina, including any core, is non-combustible; and\neach adhesive layer does not exceed 1 mm in thickness and the total thickness of the adhesive layers does not exceed 2 mm; and\nthe Spread-of-Flame Index and the Smoke-Developed Index of the bonded laminated material as a whole do not exceed 0 and 3 respectively; and\nwhen located externally, are fixed in accordance with C2D15.","g":"/ncc/c2d10","a19":["C1.9"]},{"c":"C2D11","t":"Fire hazard properties","p":"Part C2 Fire resistance and stability","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c2-fire-resistance-and-stability#C2D11","x":"(1) The fire hazard properties of the following internal linings, materials and assemblies within a Class 2 to 9 building must comply with Specification 7:\nFloor linings and floor coverings.\nWall linings and ceiling linings.\nAir-handling ductwork.\nLift cars.\nIn Class 9b buildings used as a theatre, public hall or the like—\nfixed seating in the audience area or auditorium; and\na proscenium curtain required by Specification 32.\nEscalators, moving walkways and non-required non fire-isolated stairways or pedestrian ramps subject to Specification 14.\nSarking-type materials.\nAttachments to floors, ceilings, internal walls, common walls, fire walls and to internal linings of external walls.\nOther materials including insulation materials other than sarking-type materials.\n(2) Paint or fire-retardant coatings must not be used to achieve compliance with the required fire hazard properties.\n(3) The requirements of (1) do not apply to a material or assembly if it is—\nplaster, cement render, concrete, terrazzo, ceramic tile or the like; or\na fire-protective covering; or\na timber-framed window; or\na solid timber handrail or skirting; or\na timber-faced door; or\nan electrical switch, socket-outlet, cover plate or the like; or\na material used for—\na roof insulating material applied in continuous contact with a substrate; or\nan adhesive; or\na damp-proof course, flashing, caulking, sealing, ground moisture barrier, or the like; or\na paint, varnish, lacquer or similar finish, other than nitro-cellulose lacquer; or\na clear or translucent roof light of glass fibre-reinforced polyester if—\nthe roof in which it is installed forms part of a single storey building required to be Type C construction; and\nthe material is used as part of the roof covering; and\nit is not closer than 1.5 m from another roof light of the same type; and\neach roof light is not more than 14 m2 in area; and\nthe area of the roof lights per 70 m2 of roof surface is not more than 14 m2; or\na face plate or neck adaptor of supply and return air outlets of an air handling system; or\na face plate or diffuser plate of light fitting and emergency exit signs and associated electrical wiring and electrical components; or\na joinery unit, cupboard, shelving, or the like; or\nan attached non-building fixture and fitting such as—\na curtain, blind, or similar decor, other than a proscenium curtain required by Specification 32; and\na whiteboard, window treatment or the like; or\ntimber treads, risers, landings and associated supporting framework installed in accordance with D3D30 where the Spread-of-Flame Index and the Smoke-Developed Index of the timber does not exceed 9 and 8 respectively; or\nany other material that does not significantly increase the hazards of fire.","g":"/ncc/c2d11","a19":["C1.10 and NSW C1.10","C1.10"]},{"c":"C2D12","t":"Performance of external walls in fire","p":"Part C2 Fire resistance and stability","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c2-fire-resistance-and-stability#C2D12","x":"Concrete external walls that could collapse as complete panels (e.g. tilt-up and pre-cast concrete), in a building having a rise in storeys of not more than 2, must comply with Specification 8.","g":"/ncc/c2d12","a19":["C1.11"]},{"c":"C2D13","t":"Fire-protected timber: Concession","p":"Part C2 Fire resistance and stability","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c2-fire-resistance-and-stability#C2D13","x":"Fire-protected timber may be used wherever an element is required to be non-combustible, provided—\nthe building is—\na separate building; or\na part of a building—\nwhich only occupies part of a storey, and is separated from the remaining part by a fire wall; or\nwhich is located above or below a part not containing fire-protected timber and the floor between the adjoining parts is provided with an FRL not less than that prescribed for a fire wall for the lower storey; and\nthe building has an effective height of not more than 25 m; and\nthe building has a sprinkler system (other than a FPAA101D or FPAA101H system) throughout complying with Specification 17; and\nany insulation installed in the cavity of the timber building element to have an FRL is non-combustible; and\ncavity barriers are provided in accordance with Specification 9.","g":"/ncc/c2d13","a19":["C1.13"]},{"c":"C2D14","t":"Ancillary elements","p":"Part C2 Fire resistance and stability","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c2-fire-resistance-and-stability#C2D14","x":"An ancillary element must not be fixed, installed, attached to or supported by the concealed internal parts or external face of an external wall that is required to be non-combustible unless it is one of the following:\nAn ancillary element that is non-combustible.\nA gutter, downpipe or other plumbing fixture or fitting.\nA flashing.\nA grate, grille or similar cover not more than 2 m2 in area associated with a building service.\nAn electrical switch, socket-outlet, cover plate or the like.\nA light fitting.\nA required sign.\nA sign other than one provided under (a) or (g) that—\nachieves a group number of 1 or 2; and\ndoes not extend beyond one storey; and\ndoes not extend beyond one fire compartment; and\nis separated vertically from other signs permitted under (h) by at least 2 storeys.\nAn awning, sunshade, canopy, blind or shading hood other than one provided under (a) that—\nmeets the relevant requirements of Table S7C7 as for an internal element; and\nserves a storey —\nat ground level; or\nimmediately above a storey at ground level; and\ndoes not serve an exit, where it would render the exit unusable in a fire.\nA part of a security, intercom or announcement system.\nWiring.\nWaterproofing material installed in accordance with AS 4654.2 and applied to an adjacent floor surface, including vertical upturn, or a roof surface.\nCollars, sleeves and insulation associated with service installations.\nScreens applied to vents, weepholes and gaps complying with AS 3959.\nWiper and brush seals associated with doors, windows or other openings.\nA gasket, caulking, sealant or adhesive directly associated with (a) to (o).\nLimitations\nC2D14 does not apply to ancillary elements fixed, installed or attached to the internal face or lining of an external wall.\nNotes\nC2D14 does not prevent the mounting of domestic air-conditioning condenser units on external walls.","g":"/ncc/c2d14","a19":["C1.14"]},{"c":"C2D15","t":"Fixing of bonded laminated cladding panels","p":"Part C2 Fire resistance and stability","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c2-fire-resistance-and-stability#C2D15","x":"(1) In a building required to be of Type A or B construction, externally located bonded laminated cladding panels must have all layers of cladding mechanically supported or restrained to the supporting frame.\n(2) An externally located bonded laminated cladding panel need not comply with (1) if it is one of the following:\nA laminated glass system.\nLayered plasterboard product.\nPerforated gypsum lath with a normal paper finish.\nFibrous-plaster sheet.\nFibre-reinforced cement sheeting.\nA component of a garage door.\nNotes\nFor C2D15(1), mechanical support or restraint means fixing that does not solely rely on chemical adhesive and includes concealed fixing systems such as cassette fixing, channel-type fixing and face fixing.","g":"/ncc/c2d15"},{"c":"C3D1","t":"Deemed-to-Satisfy Provisions","p":"Part C3 Compartmentation and separation","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c3-compartmentation-and-separation#C3D1","x":"(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements C1P1 to C1P9 are satisfied by complying with—\nC2D2 to C2D15, C3D2 to C3D15 and C4D2 to C4D17; and\nin a building containing an atrium, Part G3; and\nfor a building containing an occupiable outdoor area, Part G6; and\nfor additional requirements for Class 9b buildings, Part I1; and\nfor farm sheds, Part I3.\n(2) Where a Performance Solution is proposed, the relevant Performance Requirements must be determined in accordance with A2G2(3) and A2G4(3) as applicable.","g":"/ncc/c3d1","a19":["C2.0"]},{"c":"C3D2","t":"Application of Part","p":"Part C3 Compartmentation and separation","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c3-compartmentation-and-separation#C3D2","x":"(1) C3D3, C3D4 and C3D5 do not apply to a carpark provided with a sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17, an open-deck carpark or an open spectator stand.\n(2) C3D13(1)(e) does not apply to a Class 8 electricity network substation.","g":"/ncc/c3d2","a19":["C2.1"]},{"c":"Table C3D3","t":"Maximum size of fire compartments or atria","p":"Part C3 Compartmentation and separation","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c3-compartmentation-and-separation#_86bd2da3-19ae-4e94-9db2-89a69ab6604c","x":"Classification | Type A construction | Type B construction | Type C construction\n5, 9b or 9c | Max floor area —8 000 m2 | Max floor area —5 500 m2 | Max floor area —3 000 m2\nMax volume —48 000 m3 | Max volume —33 000 m3 | max volume —18 000 m3\n6, 7, 8 or 9a (except for patient care areas) | Max floor area —5 000 m2 | Max floor area —3 500 m2 | Max floor area —2 000 m2\nMax volume —30 000 m3 | Max volume —21 000 m3 | Max volume —12 000 m3\nTable Notes\nSee C3D6 for maximum size of compartments in patient care areas in Class 9a health-care buildings.","tb":"C3D3","g":"/ncc/table-c3d3"},{"c":"C3D3","t":"General floor area and volume limitations","p":"Part C3 Compartmentation and separation","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c3-compartmentation-and-separation#C3D3","x":"(1) The size of any fire compartment or atrium in a Class 5, 6, 7, 8 or 9 building must not exceed the relevant maximum floor area nor the relevant maximum volume set out in Table C3D3 and C3D6 except as permitted in C3D4.\n(2) A part of a building which contains only heating, ventilating, or lift equipment, water tanks, or similar service units is not counted in the floor area or volume of a fire compartment or atrium if it is situated at the top of the building.\n(3) In a building containing an atrium, the part of the atrium well bounded by the perimeter of the openings in the floors and extending from the level of the first floor above the atrium floor to the roof covering is not counted in the volume of the atrium for the purposes of this clause.\nTable C3D3 Maximum size of fire compartments or atria\nClassification\nType A construction\nType B construction\nType C construction\n5, 9b or 9c\nMax floor area —8 000 m2\nMax floor area —5 500 m2\nMax floor area —3 000 m2\nMax volume —48 000 m3\nMax volume —33 000 m3\nmax volume —18 000 m3\n6, 7, 8 or 9a (except for patient care areas)\nMax floor area —5 000 m2\nMax floor area —3 500 m2\nMax floor area —2 000 m2\nMax volume —30 000 m3\nMax volume —21 000 m3\nMax volume —12 000 m3\nTable Notes\nSee C3D6 for maximum size of compartments in patient care areas in Class 9a health-care buildings.","g":"/ncc/c3d3","a19":["C2.2"]},{"c":"C3D4","t":"Large isolated buildings","p":"Part C3 Compartmentation and separation","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c3-compartmentation-and-separation#C3D4","x":"The size of a fire compartment in a building may exceed that specified in Table C3D3 where—\nthe building does not exceed 18 000 m2 in floor area nor exceed 108 000 m3 in volume, if—\nthe building is Class 7 or 8 and—\ncontains not more than 2 storeys; and\nis provided with open space complying with C3D5(1) not less than 18 m wide around the building; or\nthe building is Class 5, 6, 7, 8 or 9 and is—\nprotected throughout with a sprinkler system complying with Specification 17; and\nprovided with a perimeter vehicular access complying with C3D5(2); or\nthe building is Class 5, 6, 7, 8 or 9 and exceeds 18 000 m2 in floor area or 108 000 m3 in volume, if it is—\nprotected throughout with a sprinkler system complying with Specification 17; and\nprovided with a perimeter vehicular access complying with C3D5(2); or\nthere is more than one building on the allotment and—\neach building complies with (a) or (b); or\nif the buildings are closer than 6 m to each other they are regarded as one building and collectively comply with (a) or (b).","g":"/ncc/c3d4"},{"c":"C3D5","t":"Requirements for open spaces and vehicular access","p":"Part C3 Compartmentation and separation","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c3-compartmentation-and-separation#C3D5","x":"(1) An open space required by C3D4 must—\nbe wholly within the allotment except that any road, river, or public place adjoining the allotment, but not the farthest 6 m of it may be included; and\ninclude vehicular access in accordance with (2); and\nnot be used for the storage or processing of materials; and\nnot be built upon, except for guard houses and service structures (such as electricity substations and pump houses) which may encroach upon the width of the space if they do not unduly impede fire-fighting at any part of the perimeter of the allotment or unduly add to the risk of spread of fire to any building on an adjoining allotment.\n(2) Vehicular access required by this Part—\nmust be capable of providing continuous access for emergency vehicles to enable travel in a forward direction from a public road around the entire building; and\nmust have a minimum unobstructed width of 6 m with no part of its furthest boundary more than 18 m from the building and in no part of the 6 m width be built upon or used for any purpose other than vehicular or pedestrian movement; and\nmust provide reasonable pedestrian access from the vehicular access to the building; and\nmust have a load bearing capacity and unobstructed height to permit the operation and passage of fire brigade vehicles; and\nmust be wholly within the allotment except that a public road complying with (a), (b), (c) and (d) may serve as the vehicular access or part thereof.","g":"/ncc/c3d5","a19":["C2.4"]},{"c":"C3D6","t":"Class 9 buildings","p":"Part C3 Compartmentation and separation","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c3-compartmentation-and-separation#C3D6","x":"(1) A Class 9a health-care building must comply with the following:\npatient care areas must be divided into fire compartments not exceeding 2000 m2.\nA fire compartment must be separated from the remainder of the building by fire walls and—\nin Type A construction—floors and roof or ceiling as required in Specification 5; and\nin Type B construction—floors with an FRL of not less than 120/120/120 and with the openings in external walls bounding patient care areas being vertically separated in accordance with the requirements of C3D7 as if the building were of Type A construction.\nWard areas —\nwhere the floor area exceeds 1000 m2, must be divided into floor areas not more than 1000 m2 by walls with an FRL of not less than 60/60/60; and\nwhere the floor area exceeds 500 m2, must be divided into floor areas not more than 500 m2 by smoke-proof walls complying with Specification 11; and\nwhere the floor area is not more than 500 m2, must be separated from the remainder of the patient care area by smoke-proof walls complying with Specification 11; and\nwhere division of ward areas by fire-resisting walls under (a) or (c)(i) is not required, any smoke-proof wall required under (c)(ii) or (iii) must have an FRL of not less than 60/60/60.\nTreatment areas —\nwhere the floor area exceeds 1000 m2, must be divided into floor areas not more than 1000 m2 by smoke-proof walls complying with Specification 11; and\nwhere the floor area is not more than 1000 m2, must be separated from the remainder of the patient care area by smoke-proof walls complying with Specification 11.\nAncillary use areas located within a patient care area and containing equipment or materials that are a high potential fire hazard, must be separated from the remainder of the patient care area by walls with an FRL of not less than 60/60/60.\nThe ancillary use areas referred to in (e) include, but are not limited to, the following:\nA kitchen and related food preparation areas having a combined floor area of more than 30 m2.\nA room containing a hyperbaric facility (pressure chamber).\nA room used predominantly for the storage of medical records having a floor area of more than 10 m2.\nA laundry, where items of equipment are of the type that are potential fire sources (e.g. gas fire dryers).\nA wall required by (e) to separate ancillary use areas from the remainder of the building must extend to the underside of—\nthe floor above; or\na non-combustible roof covering; or\na ceiling having a resistance to the incipient spread of fire to the space above itself of not less than 60 minutes.\nOpenings in walls required by (c) and (e) to have an FRL must be protected as follows:\nDoorways—self-closing or automatic closing –/60/30 fire doors.\nWindows—automatic or permanently fixed closed –/60/– fire windows or –/60/– automatic fire shutters.\nOther openings—construction having an FRL not less than –/60/–.\n(2) In a building containing a Class 9b early childhood centre —\nunless the Class 9b early childhood centre is the only use in the building, it must be separated from the remainder of the building by walls and/or floors with an FRL not less than that required for a fire wall; and\neach storey within the Class 9b early childhood centre must contain not less than 2 fire compartments.\n(3) A Class 9c building must comply with the following:\nA building must be divided into areas not more than 500 m2 by smoke-proof walls complying with Specification 11.\nA fire compartment must be separated from the remainder of the building by fire walls and, notwithstanding C3D8 and Specification 5, floors with an FRL of not less than 60/60/60.\nInternal walls (other than those bounding lift and stair shafts) supported by floors provided in accordance with (b) need not comply with Specification 5 if they have an FRL not less than 60/–/–.\nAncillary use areas containing equipment or materials that are a high potential fire hazard, must be separated from the sole-occupancy units by smoke-proof walls complying with Specification 11.\nThe ancillary use areas referred to in (d) include, but are not limited to, the following:\nA kitchen and related food preparation areas having a combined floor area of more than 30 m2.\nA laundry, where items of equipment are of the type that are potential fire sources (e.g. gas fired dryers).\nStorage rooms greater than 10 m2 used predominantly for the storage of administrative records.\nOpenings in fire walls must be protected as follows:\nDoorways —self-closing or automatic closing –/60/30 fire doors.\nWindows —automatic or permanently fixed closed –/60/– fire windows or –/60/– automatic fire shutters.\nOther openings — construction having an FRL not less than –/60/–.\nExemptions\nC3D6(2) does not apply to a Class 9b early childhood centre —\nwholly within a storey that provides direct egress to a road or open space; or\nwith a rise in storeys of not more than 2, where the Class 9b early childhood centre is the only use in the building.","g":"/ncc/c3d6","a19":["C2.5"]},{"c":"C3D7","t":"Vertical separation of openings in external walls","p":"Part C3 Compartmentation and separation","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c3-compartmentation-and-separation#C3D7","x":"(1) If in a building of Type A construction, any part of a window or other opening in an external wall is above another opening in the storey next below and its vertical projection falls no further than 450 mm outside the lower opening (measured horizontally), the openings must be separated by—\na spandrel which—\nis not less than 900 mm in height; and\nextends not less than 600 mm above the upper surface of the intervening floor; and\nis of non-combustible material having an FRL of not less than 60/60/60; or\npart of a curtain wall or panel wall that complies with (a); or\nconstruction that complies with (a) behind a curtain wall or panel wall and has any gaps packed with a non-combustible material that will withstand thermal expansion and structural movement of the walling without the loss of seal against fire and smoke; or\na slab or other horizontal construction that—\nprojects outwards from the external face of the wall not less than 1100 mm; and\nextends along the wall not less than 450 mm beyond the openings concerned; and\nis non-combustible and has an FRL of not less than 60/60/60.\n(2) The requirements of (1) do not apply to—\nan open-deck carpark; or\nan open spectator stand; or\na building which has a sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17 installed throughout; or\nopenings within the same stairway; or\nopenings in external walls where the floor separating the storeys does not require an FRL with respect to integrity and insulation.\n(3) For the purposes of C3D7, window or other opening means that part of the external wall of a building that does not have an FRL of 60/60/60 or greater.","g":"/ncc/c3d7","a19":["C2.6"]},{"c":"C3D8","t":"Separation by fire walls","p":"Part C3 Compartmentation and separation","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c3-compartmentation-and-separation#C3D8","x":"(1) Construction — A fire wall must be constructed in accordance with the following:\nThe fire wall has the relevant FRL prescribed by Specification 5 for each of the adjoining parts, and if these are different, the greater FRL, except where S5C19(3)(c)(i), S5C22(3)(c)(i) and S5C25(3)(c)(i) permit a lower FRL on the carpark side.\nAny openings in a fire wall must not reduce the FRL required by Specification 5 for the fire wall, except where permitted by the Deemed-to-Satisfy Provisions of Part C4.\nBuilding elements, other than roof battens with dimensions of 75 mm x 50 mm or less or sarking-type material, must not pass through or cross the fire wall unless the required fire-resisting performance of the fire wall is maintained.\n(2) Separation of buildings — A part of a building separated from the remainder of the building by a fire wall may be treated as a separate building for the purposes of the Deemed-to-Satisfy Provisions of Sections C, D and E if it is constructed in accordance with (1) and the following:\nThe fire wall extends through all storeys and spaces in the nature of storeys that are common to that part and any adjoining part of the building.\nThe fire wall is carried through to the underside of the roof covering.\nWhere the roof of one of the adjoining parts is lower than the roof of the other part, the fire wall extends to the underside of—\nthe covering of the higher roof, or not less than 6 m above the covering of the lower roof; or\nthe lower roof if it has an FRL not less than that of the fire wall and no openings closer than 3 m to any wall above the lower roof; or\nthe lower roof if its covering is non-combustible and the lower part has a sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17.\n(3) Separation of fire compartments — A part of a building separated from the remainder of the building by a fire wall may be treated as a separate fire compartment if it is constructed in accordance with (1) and the fire wall extends to the underside of—\na floor having an FRL required for a fire wall; or\nthe roof covering.","g":"/ncc/c3d8","a19":["C2.7"]},{"c":"C3D9","t":"Separation of classifications in the same storey","p":"Part C3 Compartmentation and separation","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c3-compartmentation-and-separation#C3D9","x":"(1) If a building has parts of different classifications located alongside one another in the same storey —\neach building element in that storey must have the higher FRL prescribed in Specification 5 for that element for the classifications concerned; or\nthe parts must be separated in that storey by a fire wall.\n(2) A fire wall required by (1)(b) must have the FRL prescribed in accordance with Specification 5 as applicable for that element for the Type of construction and the classifications concerned.\n(3) For the purposes of (2), the FRL in Specification 5 must be either—\nthe higher FRL prescribed in Table S5C11d or S5C21d; or\nthe FRL prescribed in Table S5C24c.\n(4) For the purposes of (1), where one part is a carpark complying with S5C19, S5C22 or S5C25, the parts may be separated by a fire wall complying with S5C19(3)(c), S5C22(3)(c) or S5C25(3)(c) as appropriate.","g":"/ncc/c3d9","a19":["C2.8"]},{"c":"C3D10","t":"Separation of classifications in different storeys","p":"Part C3 Compartmentation and separation","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c3-compartmentation-and-separation#C3D10","x":"If parts of different classification are situated one above the other in adjoining storeys they must be separated as follows:\nType A construction — The floor between the adjoining parts must have an FRL of not less than that prescribed in Specification 5 for the classification of the lower storey.\nType B or C construction — If one of the adjoining parts is of Class 2, 3 or 4, the floor separating the part from the storey below must—\nbe a floor/ceiling system incorporating a ceiling which has a resistance to the incipient spread of fire to the space above itself of not less than 60 minutes; or\nhave an FRL of at least 30/30/30; or\nhave a fire-protective covering on the underside of the floor, including beams incorporated in it, if the floor is combustible or of metal.","g":"/ncc/c3d10","a19":["C2.9"]},{"c":"C3D11","t":"Separation of lift shafts","p":"Part C3 Compartmentation and separation","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c3-compartmentation-and-separation#C3D11","x":"(1) Any lift connecting more than 2 storeys, or more than 3 storeys if the building is sprinklered, (other than lifts which are wholly within an atrium) must be separated from the remainder of the building by enclosure in a shaft in which—\nin a building required to be of Type A construction — the walls have the relevant FRL prescribed by Specification 5; and\nin a building required to be of Type B construction — the walls—\nif load bearing, have the relevant FRL prescribed by Table S5C21e; or\nif non-load bearing, be of non-combustible construction.\n(2) Any lift in a patient care area in a Class 9a health-care building or a resident use area in Class 9c building must be separated from the remainder of the building by a shaft having an FRL of not less than—\nin a building of Type A or B construction — 120/120/120; or\nin a building of Type C construction — 60/60/60.\n(3) An emergency lift must be contained within a fire-resisting shaft having an FRL of not less than 120/120/120.\n(4) Openings for lift landing doors and services must be protected in accordance with the Deemed-to-Satisfy Provisions of Part C4.","g":"/ncc/c3d11","a19":["C2.10"]},{"c":"C3D12","t":"Stairways and lifts in one shaft","p":"Part C3 Compartmentation and separation","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c3-compartmentation-and-separation#C3D12","x":"A stairway and lift must not be in the same shaft if either the stairway or the lift is required to be in a fire-resisting shaft.","g":"/ncc/c3d12","a19":["C2.11"]},{"c":"C3D13","t":"Separation of equipment","p":"Part C3 Compartmentation and separation","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c3-compartmentation-and-separation#C3D13","x":"(1) Equipment other than that described in (2) and (3) must be separated from the remainder of the building with construction complying with (4), if that equipment comprises—\nlift motors and lift control panels; or\nemergency generators used to sustain emergency equipment operating in the emergency mode; or\ncentral smoke control plant; or\nboilers; or\na battery system installed in the building that has a total voltage of 12 volts or more and a storage capacity of 200 kWh or more.\n(2) Equipment need not be separated in accordance with (1) if the equipment comprises—\nsmoke control exhaust fans located in the air stream which are constructed for high temperature operation in accordance with Specification 21; or\nexit pressurising equipment installed in compliance with the relevant provisions of AS 1668.1; or\na lift installation without a machine-room; or\nequipment otherwise adequately separated from the remainder of the building.\n(3) Separation of on-site fire pumps must comply with the requirements of AS 2419.1.\n(4) Separating construction must have—\nexcept as provided by (b)—\nan FRL as required by Specification 5, but not less than 120/120/120; and\nany doorway protected with a self-closing fire door having an FRL of not less than –/120/30; or\nwhen separating a lift shaft and lift motor room, an FRL not less than 120/–/–.","g":"/ncc/c3d13","a19":["C2.12"]},{"c":"C3D14","t":"Electricity supply system","p":"Part C3 Compartmentation and separation","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c3-compartmentation-and-separation#C3D14","x":"(1) An electricity substation located within a building must—\nbe separated from any other part of the building by construction having an FRL of not less than 120/120/120; and\nhave any doorway in that construction protected with a self-closing fire door having an FRL of not less than –/120/30.\n(2) A main switchboard located within the building which sustains emergency equipment operating in the emergency mode must—\nbe separated from any other part of the building by construction having an FRL of not less than 120/120/120; and\nhave any doorway in that construction protected with a self-closing fire door having an FRL of not less than –/120/30.\n(3) Subject to (4), electrical conductors must—\nhave a classification in accordance with AS/NZS 3013 of not less than—\nif located in a position that could be subject to damage by motor vehicles — WS53W; or\notherwise — WS52W; or\nbe enclosed or otherwise protected by construction having an FRL of not less than 120/120/120.\n(4) The requirements of (3) only apply to electrical conductors located within a building that supply—\na substation located within the building which supplies a main switchboard covered by (2); or\na main switchboard covered by (2).\n(5) Where emergency equipment is required in a building, all switchboards in the electrical installation, which sustain the electricity supply to the emergency equipment, must be constructed so that emergency equipment switchgear is separated from non-emergency equipment switchgear by metal partitions designed to minimise the spread of a fault from the non-emergency equipment switchgear.\n(6) For the purposes of (5), emergency equipment includes but is not limited to the following:\nFire hydrant booster pumps.\nPumps for automatic sprinkler systems, water spray, chemical fluid suppression systems or the like.\nPumps for fire hose reels where such pumps and fire hose reels form the sole means of fire protection in the building.\nAir handling systems designed to exhaust and control the spread of fire and smoke.\nEmergency lifts.\nControl and indicating equipment.\nEmergency warning and intercom systems.","g":"/ncc/c3d14","a19":["C2.13"]},{"c":"C3D15","t":"Public corridors in Class 2 and 3 buildings","p":"Part C3 Compartmentation and separation","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c3-compartmentation-and-separation#C3D15","x":"In a Class 2 or 3 building, a public corridor, if more than 40 m in length, must be divided at intervals of not more than 40 m with smoke-proof walls complying with S11C2.","g":"/ncc/c3d15","a19":["C2.14"]},{"c":"C4D1","t":"Deemed-to-Satisfy Provisions","p":"Part C4 Protection of openings","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c4-protection-openings#C4D1","x":"(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements C1P1 to C1P9 are satisfied by complying with—\nC2D2 to C2D15, C3D2 to C3D15 and C4D2 to C4D17; and\nin a building containing an atrium, Part G3; and\nfor a building containing an occupiable outdoor area, Part G6; and\nfor additional requirements for Class 9b buildings, Part I1; and\nfor farm sheds, Part I3.\n(2) Where a Performance Solution is proposed, the relevant Performance Requirements must be determined in accordance with A2G2(3) and A2G4(3) as applicable.","g":"/ncc/c4d1","a19":["C3.0"]},{"c":"C4D2","t":"Application of Part","p":"Part C4 Protection of openings","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c4-protection-openings#C4D2","x":"(1) The Deemed-to-Satisfy Provisions of this Part do not apply to the following:\nControl joints, weep holes and the like in external walls of masonry construction and joints between panels in external walls of pre-cast concrete panel construction if, in all cases they are not larger than necessary for the purpose.\nNon-combustible ventilators for subfloor or cavity ventilation, if each does not exceed 45 000 mm2 in face area and is spaced not less than 2 m from any other ventilator in the same wall.\nOpenings in the vertical plane formed between building elements at the construction edge or perimeter of a balcony or verandah, colonnade, terrace, or the like.\nIn a carpark floor other than a floor that separates a part not used as a carpark, and subject to (e), the following openings in a carpark floor:\nService penetrations.\nOpenings formed by a vehicle ramp.\nThe requirements of (d) only apply where the connected carpark levels comply as a single fire compartment for the purposes of all other requirements of the Deemed-to-Satisfy Provisions of Sections C, D and E.\n(2) For the purposes of the Deemed-to-Satisfy Provisions of this Part, openings in building elements required to be fire-resisting include doorways, windows (including any associated fanlight), infill panels and fixed or openable glazed areas that do not have the required FRL.\n(3) For the purposes of the Deemed-to-Satisfy Provisions of this Part, openings, other than those covered under (1)(c), between building elements such as columns, beams and the like, in the plane formed at the construction edge or perimeter of the building, are deemed to be openings in an external wall.","g":"/ncc/c4d2","a19":["C3.1"]},{"c":"C4D3","t":"Protection of openings in external walls","p":"Part C4 Protection of openings","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c4-protection-openings#C4D3","x":"(1) Subject to (2), openings in an external wall, or openings in part of an external wall, where that external wall or external wall part is required to have an FRL must be protected in accordance with C4D5, and if wall-wetting sprinklers are used, they must be located externally.\n(2) The requirements of (1) only apply if the distance between the opening and the fire-source feature to which it is exposed is less than—\n3 m from a side or rear boundary of the allotment; or\n6 m from the far boundary of a road, river, lake or the like adjoining the allotment, if not located in a storey at or near ground level; or\n6 m from another building on the allotment that is not Class 10.\n(3) Openings required to be protected under (1), must not occupy more than 1/3 of the area of the external wall of the storey in which they are located unless they are in a Class 9b building used as an open spectator stand.","g":"/ncc/c4d3","a19":["C3.2"]},{"c":"Table C4D4","t":"Distance between external walls and associated openings in different fire compartments","p":"Part C4 Protection of openings","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c4-protection-openings#_1fcb6234-ed10-4957-b2cb-83458bb42821","x":"Angle between walls | Minimum distance (m)\n0° (walls opposite) | 6\nmore than 0° to 45° | 5\nmore than 45° to 90° | 4\nmore than 90° to 135° | 3\nmore than 135° to less than 180° | 2\n180° or more | Nil","tb":"C4D4","g":"/ncc/table-c4d4"},{"c":"C4D4","t":"Separation of external walls and associated openings in different fire compartments","p":"Part C4 Protection of openings","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c4-protection-openings#C4D4","x":"The distance between parts of external walls and any openings within them in different fire compartments separated by a fire wall must not be less than that set out in Table C4D4, unless—\nthose parts of each wall have an FRL not less than 60/60/60; and\nany openings are protected in accordance with C4D5.\nTable C4D4 Distance between external walls and associated openings in different fire compartments\nAngle between walls\nMinimum distance (m)\n0° (walls opposite)\n6\nmore than 0° to 45°\n5\nmore than 45° to 90°\n4\nmore than 90° to 135°\n3\nmore than 135° to less than 180°\n2\n180° or more\nNil","g":"/ncc/c4d4","a19":["C3.3"]},{"c":"C4D5","t":"Acceptable methods of protection","p":"Part C4 Protection of openings","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c4-protection-openings#C4D5","x":"(1) Where protection is required, doorways, windows and other openings must be protected as follows:\nDoorways—\ninternal or external wall-wetting sprinklers as appropriate used with doors that are self-closing or automatic closing; or\n–/60/30 fire doors that are self-closing or automatic closing.\nWindows —\ninternal or external wall-wetting sprinklers as appropriate used with windows that are automatic closing or permanently fixed in the closed position; or\n–/60/– fire windows that are automatic closing or permanently fixed in the closed position; or\n–/60/– automatic closing fire shutters.\nOther openings—\nexcluding voids — internal or external wall-wetting sprinklers, as appropriate; or\nconstruction having an FRL not less than –/60/–.\n(2) Fire doors, fire windows and fire shutters must comply with Specification 12.","g":"/ncc/c4d5","a19":["C3.4"]},{"c":"C4D6","t":"Doorways in fire walls","p":"Part C4 Protection of openings","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c4-protection-openings#C4D6","x":"(1) The aggregate width of openings for doorways in a fire wall, which are not part of a horizontal exit, must not exceed ½ of the length of the fire wall, and each doorway must be protected by—\n2 fire doors or fire shutters, one on each side of the doorway, each of which has an FRL of not less than ½ that required by Specification 5 for the fire wall except that each door or shutter must have an insulation level of at least 30; or\na fire door on one side and a fire shutter on the other side of the doorway, each of which complies with (a); or\na single fire door or fire shutter which has an FRL of not less than that required by Specification 5 for the fire wall except that each door or shutter must have an insulation level of at least 30.\n(2) A fire door or fire shutter required by (1)(a), (b) or (c) must be self-closing, or automatic closing in accordance with (3) and (4).\n(3) The automatic closing operation required by (2) must be initiated by the activation of a smoke detector, or any other detector deemed suitable in accordance with AS 1670.1 if smoke detectors are unsuitable in the atmosphere, installed in accordance with the relevant provisions of AS 1670.1 and located on each side of the fire wall not more than 1.5 m horizontal distance from the opening.\n(4) Where any other required suitable fire alarm system, including a sprinkler system (other than a FPAA101D system) complying with Specification 17, is installed in the building, activation of the system in either fire compartment separated by the fire wall must also initiate the automatic closing operation.","g":"/ncc/c4d6","a19":["C3.5"]},{"c":"C4D7","t":"Sliding fire doors","p":"Part C4 Protection of openings","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c4-protection-openings#C4D7","x":"(1) If a doorway in a fire wall is fitted with a sliding fire door which is open when the building is in use—\nit must be held open with an electromagnetic device, which when de-activated in accordance with (2) and (3), allows the door to be fully closed in not less than 20 seconds and not more than 30 seconds after release; and\nin the event of power failure to the door — the door must fail safe in the closed position in accordance with (a); and\nan audible warning device must be located near the doorway and a red flashing warning light of adequate intensity on each side of the doorway must be activated in accordance with (2) and (3); and\nsigns must be installed on each side of the doorway located directly over the opening stating, in capital letters not less than 50 mm high in a colour contrasting with the background:\nWARNING — SLIDING FIRE DOOR\n(2) The electromagnetic device required by (1)(a) must be de-activated and the warning system activated by heat or smoke detectors, as appropriate, installed in accordance with AS 1905.1 and the relevant provisions of AS 1670.1.\n(3) Where any other required suitable fire alarm system, including a sprinkler system (other than a FPAA101D system) complying with Specification 17, is installed in the building, activation in either fire compartment separated by the fire wall must also de-activate the electromagnetic device and activate the warning system.","g":"/ncc/c4d7","a19":["C3.6"]},{"c":"C4D8","t":"Protection of doorways in horizontal exits","p":"Part C4 Protection of openings","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c4-protection-openings#C4D8","x":"(1) A doorway that is part of a horizontal exit must be protected by either—\na single fire door that has an FRL of not less than that required by Specification 5 for the fire wall except that the door must have an insulation level of at least 30; or\nin a Class 7 or 8 building — 2 fire doors, one on each side of the doorway, each with an FRL of not less than ½ that required by Specification 5 for the fire wall except that each door must have an insulation level of at least 30.\n(2) Each door required by (1) must be self-closing, or automatic -closing in accordance with the following:\nThe automatic -closing operation must be initiated by the activation of a smoke detector, or any other detector deemed suitable in accordance with AS 1670.1 if smoke detectors are unsuitable in the atmosphere, installed in accordance with the relevant provisions of AS 1670.1 and located on each side of the fire wall not more than 1.5 m horizontal distance from the opening.\nWhere any other required suitable fire alarm system, including a sprinkler system (other than a FPAA101D system) complying with Specification 17, is installed in the building, activation of the system in either fire compartment separated by the fire wall must also initiate the automatic -closing operation.","g":"/ncc/c4d8","a19":["C3.7"]},{"c":"C4D9","t":"Openings in fire-isolated exits","p":"Part C4 Protection of openings","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c4-protection-openings#C4D9","x":"(1) Doorways that open to fire-isolated stairways, fire-isolated passageways or fire-isolated ramps, and are not doorways opening to a road or open space, must be protected by –/60/30 fire doors that are self-closing, or automatic closing in accordance with (2) and (3).\n(2) The automatic -closing operation required by (1) must be initiated by the activation of a smoke detector, or any other detector deemed suitable in accordance with AS 1670.1 if smoke detectors are unsuitable in the atmosphere, installed in accordance with the relevant provisions of AS 1670.1 and located not more than 1.5 m horizontal distance from the approach side of the doorway.\n(3) Where any other required suitable fire alarm system, including a sprinkler system (other than a FPAA101D system) complying with Specification 17, is installed in the building, activation of the system must also initiate the automatic -closing operation.\n(4) A window in an external wall of a fire-isolated stairway, fire-isolated passageway or fire-isolated ramp must be protected in accordance with C4D5 if it is within 6 m of, and exposed to, a window or other opening in a wall of the same building, other than in the same fire-isolated enclosure.","g":"/ncc/c4d9","a19":["C3.8"]},{"c":"C4D10","t":"Service penetrations in fire-isolated exits","p":"Part C4 Protection of openings","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c4-protection-openings#C4D10","x":"Fire-isolated exits must not be penetrated by any services other than—\nelectrical wiring permitted by D3D8(6) to be installed within the exit; or\nducting associated with a pressurisation system if it—\nis constructed of material having an FRL of not less than –/120/60 where it passes through any other part of the building; and\ndoes not open into any other part of the building; or\nfor fire services, water supply and test drain pipes; or\nwiring, sensors and the like required for the function and performance of a pressurisation system serving the exit.","g":"/ncc/c4d10","a19":["C3.9"]},{"c":"C4D11","t":"Openings in fire-isolated lift shafts","p":"Part C4 Protection of openings","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c4-protection-openings#C4D11","x":"(1) Doorways — If a lift shaft is required to be fire-isolated, an entrance doorway to that shaft must be protected by –/60/– fire doors that—\ncomply with AS 1735.11; and\nare set to remain closed except when discharging or receiving passengers, goods or vehicles.\n(2) Lift indicator panels — A lift call panel, indicator panel or other panel in the wall of a fire-isolated lift shaft must be backed by construction having an FRL of not less than –/60/60 if it exceeds 35 000 mm2 in area.","g":"/ncc/c4d11","a19":["C3.10"]},{"c":"C4D12","t":"Bounding construction: Class 2 and 3 buildings and Class 4 parts","p":"Part C4 Protection of openings","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c4-protection-openings#C4D12","x":"(1) A doorway in a Class 2 or 3 building must be protected if it provides access from a sole-occupancy unit to—\na public corridor, public lobby, or the like; or\na room not within a sole-occupancy unit; or\nthe landing of an internal non fire-isolated stairway that serves as a required exit; or\nanother sole-occupancy unit.\n(2) A doorway in a Class 2 or 3 building must be protected if it provides access from a room not within a sole-occupancy unit to—\na public corridor, public lobby, or the like; or\nthe landing of an internal non fire-isolated stairway that serves as a required exit.\n(3) A doorway in a Class 4 part of a building must be protected if it provides access to any other internal part of the building.\n(4) Except as provided in (5), protection for a doorway must be at least—\nin a building of Type A construction — a self-closing –/60/30 fire door; and\nin a building of Type B or C construction — a self-closing, tight fitting, solid core door, not less than 35 mm thick.\n(5) In a Class 3 building used as a residential care building protected with a sprinkler system complying with Specification 17, protection for a doorway must be at least—\na tight fitting, solid core door not less than 35 mm thick if the building is divided into floor areas not exceeding 500 m2 with smoke proof walls complying with S11C2; or\na tight fitting, solid core door not less than 35 mm thick fitted with a self-closing device, a delayed closing device or an automatic closing device.\n(6) Other openings in internal walls which are required to have an FRL with respect to integrity and insulation must not reduce the fire-resisting performance of the wall.\n(7) A door required by (4) or (5) may be automatic -closing in accordance with the following:\nThe automatic -closing operation must be initiated by the activation of a smoke detector, or any other detector deemed suitable in accordance with AS 1670.1 if smoke detectors are unsuitable in the atmosphere, installed in accordance with the relevant provisions of AS 1670.1 and located not more than 1.5 m horizontal distance from the approach side of the doorway.\nWhere any other required suitable fire alarm system, including a sprinkler system (other than a FPAA101D system) complying with Specification 17, is installed in the building, activation of the system must also initiate the automatic -closing operation.\n(8) The requirements of (9) apply in a Class 2 or 3 building where a path of travel to an exit —\ndoes not provide a person seeking egress with a choice of travel in different directions to alternative exits; and\nis along an open balcony, landing or the like; and\npasses an external wall of—\nanother sole-occupancy unit; or\na room not within a sole-occupancy unit.\n(9) The external wall mentioned in (8)(c) must—\nbe constructed of concrete or masonry, or be lined internally with a fire-protective covering; and\nhave any doorway fitted with a self-closing, tight-fitting solid core door not less than 35 mm thick; and\nhave any windows or other openings—\nprotected internally in accordance with C4D5; or\nlocated at least 1.5 m above the floor of the balcony, landing or the like.","g":"/ncc/c4d12","a19":["C3.11"]},{"c":"C4D13","t":"Openings in floors and ceilings for services","p":"Part C4 Protection of openings","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c4-protection-openings#C4D13","x":"(1) Where a service passes through—\na floor that is required to have an FRL with respect to integrity and insulation; or\na ceiling required to have a resistance to the incipient spread of fire,\nthe service must be installed in accordance with (2).\n(2) A service must be protected—\nin a building of Type A construction, by a shaft complying with Specification 5; or\nin a building of Type B or C construction, by a shaft that will not reduce the fire performance of the building elements it penetrates; or\nin accordance with C4D15.\n(3) Where a service passes through a floor which is required to be protected by a fire-protective covering, the penetration must not reduce the fire performance of the covering.","g":"/ncc/c4d13","a19":["C3.12"]},{"c":"C4D14","t":"Openings in shafts","p":"Part C4 Protection of openings","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c4-protection-openings#C4D14","x":"In a building of Type A construction, an opening in a wall providing access to a ventilating, pipe, garbage or other service shaft must be protected by—\nif it is in a sanitary compartment — a door or panel which, together with its frame, is non-combustible or has an FRL of not less than –/30/30; or\na self-closing –/60/30 fire door or hopper; or\nan access panel having an FRL of not less than –/60/30; or\nif the shaft is a garbage shaft — a door or hopper of non-combustible construction.","g":"/ncc/c4d14","a19":["C3.13"]},{"c":"C4D15","t":"Openings for service installations","p":"Part C4 Protection of openings","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c4-protection-openings#C4D15","x":"(1) The requirements of (2) apply where an electrical, electronic, plumbing, mechanical ventilation, air-conditioning or other service penetrates a building element (other than an external wall or roof) that is required to have an FRL with respect to integrity or insulation or a resistance to the incipient spread of fire.\n(2) An installation mentioned in (1) must comply with any one of the following:\nTested systems — the following applies:\nThe service, building element and any protection method at the penetration—\nare identical with a prototype assembly of the service, building element and protection method which has been tested in accordance with AS 4072.1 and AS 1530.4 and has achieved the required FRL or resistance to the incipient spread of fire; or\ndiffer from a prototype assembly of the service, building element and protection method in accordance with Section 4 of AS 4072.1.\nIt complies with (i) except for the insulation criteria relating to the service if—\nthe service is a pipe system comprised entirely of metal (excluding pipe seals or the like); and\nany combustible building element is not located within 100 mm of the service for a distance of 2 m from the penetration; and\ncombustible material is not able to be located within 100 mm of the service for a distance of 2 m from the penetration; and\nit is not located in a required exit.\nThe determination of the required FRL must be confirmed in a report from an Accredited Testing Laboratory in accordance with Specifications 1 and 2.\nVentilation and air-conditioning — in the case of ventilating or air-conditioning ducts or equipment, the opening is protected in accordance with AS 1668.1.\nCompliance with Specification 13 — the following applies:\nThe service is a pipe system comprised entirely of metal (excluding pipe seals or the like) and is installed in accordance with Specification 13 and it—\npenetrates a wall, floor or ceiling, but not a ceiling required to have a resistance to the incipient spread of fire; and\nconnects not more than 2 fire compartments in addition to any fire-resisting service shafts; and\ndoes not contain a flammable or combustible liquid or gas.\nThe service is sanitary plumbing installed in accordance with Specification 13 and it—\nis of metal or UPVC pipe; and\npenetrates the floors of a Class 5, 6, 7, 8 or 9b building; and\nis in a sanitary compartment separated from other parts of the building by walls with the FRL required by Specification 5 for a stair shaft in the building and a self-closing –/60/30 fire door.\nThe service is a wire or cable, or a cluster of wires or cables installed in accordance with Specification 13 and it—\npenetrates a wall, floor or ceiling, but not a ceiling required to have a resistance to the incipient spread of fire; and\nconnects not more than 2 fire compartments in addition to any fire-resisting service shafts.\nThe service is an electrical switch, outlet, or the like, and it is installed in accordance with Specification 13.","g":"/ncc/c4d15","a19":["C3.15"]},{"c":"C4D16","t":"Construction joints","p":"Part C4 Protection of openings","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c4-protection-openings#C4D16","x":"(1) Construction joints, spaces and the like in and between building elements required to be fire-resisting with respect to integrity and insulation must be protected in a manner—\nidentical with a prototype tested in accordance with AS 4072.1 and AS 1530.4 to achieve the required FRL; or\nthat differs from a prototype in accordance with Section 4 of AS 4072.1 and achieves the required FRL.\n(2) The determination of the required FRL must be confirmed in a report from an Accredited Testing Laboratory in accordance with Specifications 1 and 2.\n(3) The requirements of (1) do not apply where joints, spaces and the like between fire-protected timber elements are provided with cavity barriers in accordance with Specification 9.","g":"/ncc/c4d16","a19":["C3.16"]},{"c":"C4D17","t":"Columns protected with lightweight construction to achieve an FRL","p":"Part C4 Protection of openings","u":"/editions/ncc-2025/adopted/volume-one/c-fire-resistance/part-c4-protection-openings#C4D17","x":"A column protected by lightweight construction to achieve an FRL which passes through a building element that is required to have an FRL or a resistance to the incipient spread of fire, must be installed using a method and materials identical with a prototype assembly of the construction which has achieved the required FRL or resistance to the incipient spread of fire.","g":"/ncc/c4d17","a19":["C3.17"]},{"c":"S14C1","t":"Scope","p":"Specification 14 Non-required stairways, ramps and escalators","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/14-non-required-stairways-ramps-and-escalators#S14C1","x":"(1) This Specification contains the requirements to allow non-required stairways, ramps or escalators to connect any number of storeys in a Class 5 or 6 building.\n(2) The requirements do not apply in an atrium or outside a building.","g":"/ncc/s14c1","a19":["Spec D1.12: 1"]},{"c":"S14C2","t":"Requirements","p":"Specification 14 Non-required stairways, ramps and escalators","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/14-non-required-stairways-ramps-and-escalators#S14C2","x":"An escalator, moving walkway or non-required non-fire-isolated stairway or pedestrian ramp must comply with the following:\nThe escalator, walkway, stairway or ramp must be bounded by a shaft of—\nconstruction with an FRL of not less than 120/120/120 if load bearing or –/120/120 if non-load bearing and, if of lightweight construction, must comply with Specification 6; or\nglazed construction with an FRL of not less than –/60/30 protected by a wall wetting system in accordance with S31C2 to S31C6.\nThe void of each non-required stairway, ramp or escalator must not connect more than 2 storeys.\nRising and descending escalators, walkways, stairways and ramps within one shaft must be separated by construction with an FRL of not less than –/60/30.\nOpenings into the shaft must be protected by fire doors with an FRL not less than –/60/30.\nWhen the fire door is in the closed position, the floor or any covering over the floor beneath the fire door must not be combustible.\nFire doors must be fitted with smoke seals and the assembly must be tested in accordance with AS 1530.4.\nFire doors must be—\nclosed and locked for security reasons; or\nheld open and be automatic closing.\nSmoke detectors must be installed on both sides of the opening, not more than 1.5 m horizontal distance from the opening.\nIn the closed position, fire doors must be openable on a single hand downward action or horizontal pushing action on a single device within the shaft and by key only from outside the shaft.\nA warning sign must be displayed where it can readily be seen outside the shaft near all fire doors opening to the shaft, and must comply with the details and dimensions of Figure S14C2.\nAll doors opening into the shaft must be within 20 m of a required exit.\nSigns showing the direction of the nearest required exit must be installed where they can be readily seen.\nMaterials attached to any wall, ceiling or floor within the shaft must comply with Specification 7.\nEmergency lighting must be installed in the shaft in accordance with E4D4.\nNo step or ramp may be closer to the threshold of the doorway than the width of the door leaf.\nFigure S14C2 Warning sign for non-required stairway, ramp or escalator","g":"/ncc/s14c2","a19":["Spec D1.12: 2"]},{"c":"S15C1","t":"Scope","p":"Specification 15 Braille and tactile signs","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/15-braille-and-tactile-signs#S15C1","x":"This Specification sets out the requirements for the design and installation of braille and tactile signage as required by D3D26, D4D7 and Specification 27.","g":"/ncc/s15c1","a19":["Spec D3.6: 1"]},{"c":"S15C2","t":"Location of braille and tactile signs","p":"Specification 15 Braille and tactile signs","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/15-braille-and-tactile-signs#S15C2","x":"Signs including symbols, numbering and lettering must be designed and installed as follows:\nBraille and tactile components of a sign must be located not less than 1200 mm and not higher than 1600 mm above the floor or ground surface.\nSigns with single lines of characters must have the line of tactile characters not less than 1250 mm and not higher than 1350 mm above the floor or ground surface.\nSigns identifying rooms containing features or facilities listed in D4D7 must be located—\non the wall on the latch side of the door with the leading edge of the sign located between 50 mm and 300 mm from the architrave; and\nwhere (i) is not possible, the sign may be placed on the door itself.\nSigns identifying a door required by E4D5 to be provided with an exit sign must be located—\non the side that faces a person seeking egress; and\non the wall on the latch side of the door with the leading edge of the sign located between 50 mm and 300 mm from the architrave; and\nwhere (ii) is not possible, the sign may be placed on the door itself.","g":"/ncc/s15c2","a19":["Spec D3.6: 2"]},{"c":"S15C3","t":"Braille and tactile sign specification","p":"Specification 15 Braille and tactile signs","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/15-braille-and-tactile-signs#S15C3","x":"(1) Tactile characters must be raised or embossed to a height of not less than 1 mm and not more than 1.5 mm.\n(2) Title case must be used for all tactile characters, and—\nupper case tactile characters must have a height of not less than 15 mm and not more than 55 mm, except that the upper case tactile characters on a sign identifying a door required by E4D5 to be provided with an exit sign must have a height of not less than 20 mm and not more than 55 mm; and\nlower case tactile characters must have a minimum height of 50% of the related upper case characters.\n(3) Tactile characters, symbols, and the like, must have rounded edges.\n(4) The entire sign, including any frame, must have all edges rounded.\n(5) The background, negative space or fill of signs must be of matt or low sheen finish.\n(6) The characters, symbols, logos and other features on signs must be matt or low sheen finish.\n(7) The minimum letter spacing of tactile characters on signs must be 2 mm.\n(8) The minimum word spacing of tactile characters on signs must be 10 mm.\n(9) The thickness of letter strokes must be not less than 2 mm and not more than 7 mm.\n(10) Tactile text must be left justified, except that single words may be centre justified.\n(11) Tactile text must be Arial typeface.","g":"/ncc/s15c3","a19":["Spec D3.6: 3"]},{"c":"S15C4","t":"Luminance contrast","p":"Specification 15 Braille and tactile signs","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/15-braille-and-tactile-signs#S15C4","x":"The following applies to luminance contrast:\nThe background, negative space, fill of a sign or border with a minimum width of 5 mm must have a luminance contrast with the surface on which it is mounted of not less than 30%.\nTactile characters, icons and symbols must have a minimum luminance contrast of 30% to the surface on which the characters are mounted.\nLuminance contrasts must be met under the lighting conditions in which the sign is to be located.","g":"/ncc/s15c4","a19":["Spec D3.6: 4"]},{"c":"S15C5","t":"Lighting","p":"Specification 15 Braille and tactile signs","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/15-braille-and-tactile-signs#S15C5","x":"Braille and tactile signs must be illuminated to ensure luminance contrast requirements are met at all times during which the sign is required to be read.","g":"/ncc/s15c5","a19":["Spec D3.6: 5"]},{"c":"S15C6","t":"Braille","p":"Specification 15 Braille and tactile signs","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/15-braille-and-tactile-signs#S15C6","x":"The following applies to braille:\nBraille must be grade 1 braille (uncontracted) in accordance with the criteria set out by the Australian Braille Authority.\nBraille must be raised and domed.\nBraille must be located 8 mm below the bottom line of text (not including descenders).\nBraille must be left justified.\nWhere an arrow is used in the tactile sign, a solid arrow must be provided for braille readers.\nOn signs with multiple lines of text and characters, a semicircular braille locator at the left margin must be horizontally aligned with the first line of braille text.","g":"/ncc/s15c6","a19":["Spec D3.6: 6"]},{"c":"S16C1","t":"Scope","p":"Specification 16 Accessible water entry/exit from swimming pools","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/16-accessible-water-entryexit-swimming-pools#S16C1","x":"This Specification sets out the requirements for types of accessible water entry/exit for swimming pools.","g":"/ncc/s16c1","a19":["Spec D3.10: 1"]},{"c":"S16C2","t":"Fixed or moveable ramp","p":"Specification 16 Accessible water entry/exit from swimming pools","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/16-accessible-water-entryexit-swimming-pools#S16C2","x":"A fixed or moveable ramp must—\nhave a slip-resistant surface; and\nhave a maximum gradient of 1:14; and\nhave handrails complying with the requirements for ramps in AS 1428.1, installed on both sides of the ramp; and\nhave kerbs in accordance with the requirements for ramps in AS 1428.1; and\nextend to a depth of not less than 900 mm and not more than 1100 mm below the stationary water level; and\nhave landings in accordance with the requirements for ramps in AS 1428.1, with a landing located at the bottom and top of each ramp and a landing must be located at a level between 900 mm and 1100 mm below the stationary water level.","g":"/ncc/s16c2","a19":["Spec D3.10: 2"]},{"c":"S16C3","t":"Zero depth entry","p":"Specification 16 Accessible water entry/exit from swimming pools","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/16-accessible-water-entryexit-swimming-pools#S16C3","x":"A zero depth entry must have—\na slip-resistant surface; and\na maximum gradient of 1:14; and\na single handrail complying with the requirements for handrails in AS 1428.1, from the top of the entry point continuous to the bottom level area; and\na level area—\n1500 mm long for the width of the zero depth entry at the entry point; and\nlocated at the bottom of the zero depth entry at a level between 900 mm and 1100 mm below the stationary water level.","g":"/ncc/s16c3","a19":["Spec D3.10: 3"]},{"c":"S16C4","t":"Platform swimming pool lift","p":"Specification 16 Accessible water entry/exit from swimming pools","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/16-accessible-water-entryexit-swimming-pools#S16C4","x":"A platform swimming pool lift must be—\ncapable of being operated from the swimming pool surround, within the swimming pool, and on the platform; and\nlocated where the water depth is not more than 1300 mm; and\ndesigned to withstand a weight capacity of not less than 160 kg and be capable of sustaining a static load of not less than 1.5 times the rated load.","g":"/ncc/s16c4","a19":["Spec D3.10: 4"]},{"c":"S16C5","t":"Sling-style swimming pool lift","p":"Specification 16 Accessible water entry/exit from swimming pools","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/16-accessible-water-entryexit-swimming-pools#S16C5","x":"A sling lift must comply with the following:\nA sling lift must be located where the water depth is not more than 1300 mm.\nWhen the sling is in the raised position and in the transfer position, the centreline of the sling must be located over the swimming pool surround and not less than 450 mm from the swimming pool edge.\nThe surface of the swimming pool surround between the centreline of the sling and the swimming pool edge must have a gradient of not more than 1:50 and must be slip-resistant.\nA clear space must be provided on the swimming pool surround parallel with the swimming pool edge on the side remote from the water (see Figure S16C5a and Figure S16C5b) and must—\nbe not less than 900 mm x 1300 mm; and\nhave a gradient of not more than 1:50; and\nhave a slip-resistant surface; and\nbe located so that the centreline of the space is directly below the lifting point for the sling.\nA sling lift must be capable of being operated from the swimming pool surround, within the swimming pool and from the sling.\nA sling must be designed so that it will submerge to a water depth of not less than 500 mm below the stationary water level.\nA sling lift must be designed to withstand a weight of not less than 136 kg and be capable of sustaining a static load not less than 1.5 times the rated load.\nFigure S16C5a Clear swimming pool surround space for sling lift in the transfer position — Plan view\nFigure S16C5b Clear swimming pool surround space for sling lift in the transfer position — Sectional elevation","g":"/ncc/s16c5","a19":["Spec D3.10: 5"]},{"c":"S16C6","t":"Aquatic wheelchair","p":"Specification 16 Accessible water entry/exit from swimming pools","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/16-accessible-water-entryexit-swimming-pools#S16C6","x":"An aquatic wheelchair must comply with the following:\nThe height of the top surface of the seat must be not less than 430 mm.\nThe seat width must not be not less than 480 mm.\nA footrest must be provided.\nArmrests must be located on both sides of the seat and must be capable of being moved away from the side of the chair to allow a person to transfer on and off the seat.","g":"/ncc/s16c6","a19":["Spec D3.10: 6"]},{"c":"D1O1","t":"Objective","p":"Part D1 Access and egress","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d1-access-and-egress#D1O1","x":"The Objective of this Section is to—\nprovide, as far as is reasonable, people with safe, equitable and dignified access to—\na building; and\nthe services and facilities within a building; and\nsafeguard occupants from illness or injury while evacuating in an emergency.","g":"/ncc/d1o1","a19":["DO1"]},{"c":"D1F1","t":"Access","p":"Part D1 Access and egress","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d1-access-and-egress#D1F1","x":"A building is to provide, as far as is reasonable—\nsafe; and\nequitable and dignified,\naccess for people to the services and facilities within.\nLimitations\nD1F1(b) does not apply to a Class 4 part of a building.","g":"/ncc/d1f1","a19":["DF1"]},{"c":"D1F2","t":"Egress","p":"Part D1 Access and egress","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d1-access-and-egress#D1F2","x":"A building is to be provided with means of evacuation which allow occupants time to evacuate safely without being overcome by the effects of an emergency.\nLimitations\nD1F2 does not apply to the internal parts of a sole-occupancy unit in a Class 2 or 3 building or Class 4 part of a building.","g":"/ncc/d1f2","a19":["DF2"]},{"c":"D1P1","t":"Access for people with a disability","p":"Part D1 Access and egress","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d1-access-and-egress#D1P1","x":"Access must be provided, to the degree necessary, to enable—\npeople to—\napproach the building from the road boundary and from any accessible carparking spaces associated with the building; and\napproach the building from any accessible associated building; and\naccess work and public spaces, accommodation and facilities for personal hygiene; and\nidentification of accessways at appropriate locations which are easy to find.\nLimitations\nD1P1 does not apply to a Class 4 part of a building.","g":"/ncc/d1p1","a19":["DP1"]},{"c":"D1P2","t":"Safe movement to and within a building","p":"Part D1 Access and egress","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d1-access-and-egress#D1P2","x":"So that people can move safely to and within a building, it must have—\nwalking surfaces with safe gradients; and\nany doors installed to avoid the risk of occupants—\nhaving their egress impeded; or\nbeing trapped in the building; and\nany stairways and ramps with—\nslip-resistant walking surfaces on—\nramps; and\nstairway treads or near the edge of the nosing; and\nsuitable handrails where necessary to assist and provide stability to people using the stairway or ramp; and\nsuitable landings to avoid undue fatigue; and\nlandings where a door opens from or onto the stairway or ramp so that the door does not create an obstruction; and\nin the case of a stairway, suitable safe passage in relation to the nature, volume and frequency of likely usage.\nLimitations\nD1P2(c) does not apply to threshold ramps, except D1P2(c)(i)(A) applies to threshold ramps provided for people with a disability.","g":"/ncc/d1p2","a19":["DP2"]},{"c":"D1P3","t":"Fall prevention barriers","p":"Part D1 Access and egress","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d1-access-and-egress#D1P3","x":"(1) A barrier must be provided where people could fall—\n1 m or more—\nfrom a floor or roof or through an opening (other than through an openable window) in the external wall of a building; or\ndue to a sudden change of level within or associated with a building; or\n2 m or more from a floor through an openable window—\nin a bedroom in a Class 2 or 3 building or a Class 4 part of a building; or\nin a Class 9b early childhood centre; or\n4 m or more from a floor through an openable window not covered by (b).\n(2) A barrier required by (1) must be—\ncontinuous and extend for the full extent of the hazard; and\nof a height to protect people from accidentally falling from the floor or roof or through the opening or openable window; and\nconstructed to prevent people from falling through the barrier; and\ncapable of restricting the passage of children; and\nof strength and rigidity to withstand—\nthe foreseeable impact of people; and\nwhere appropriate, the static pressure of people pressing against it.\nLimitations\nD1P3 does not apply where such barrier would be incompatible with the intended use of an area such as a stage, loading dock or the like.\nD1P3(2)(d) does not apply to—\nfire-isolated stairways, fire-isolated ramps, and other areas used primarily for emergency purposes, excluding external stairways and ramps; and\nClass 7 (other than carparks) and Class 8 buildings and parts of buildings containing those classifications.","g":"/ncc/d1p3","a19":["DP3"]},{"c":"D1P4","t":"Exits","p":"Part D1 Access and egress","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d1-access-and-egress#D1P4","x":"Exits must be provided from a building to allow occupants to evacuate safely, with their number, location and dimensions being appropriate to—\nthe travel distance; and\nthe number, mobility and other characteristics of occupants; and\nthe function or use of the building; and\nthe height of the building; and\nwhether the exit is from above or below ground level.","g":"/ncc/d1p4","a19":["DP4"]},{"c":"D1P5","t":"Fire-isolated exits","p":"Part D1 Access and egress","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d1-access-and-egress#D1P5","x":"To protect evacuating occupants from a fire in the building exits must be fire-isolated, to the degree necessary, appropriate to—\nthe number of storeys connected by the exits; and\nthe fire safety system installed in the building; and\nthe function or use of the building; and\nthe number of storeys passed through by the exits; and\nfire brigade intervention.","g":"/ncc/d1p5","a19":["DP5"]},{"c":"D1P6","t":"Paths of travel to exits","p":"Part D1 Access and egress","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d1-access-and-egress#D1P6","x":"So that occupants can safely evacuate the building, paths of travel to exits must have dimensions appropriate to—\nthe number, mobility and other characteristics of occupants; and\nthe function or use of the building.\nLimitations\nD1P6 does not apply to the internal parts of a sole-occupancy unit in a Class 2 or 3 building or Class 4 part of a building.","g":"/ncc/d1p6","a19":["DP6"]},{"c":"D1P7","t":"Evacuation lifts","p":"Part D1 Access and egress","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d1-access-and-egress#D1P7","x":"Where a lift is intended to be used in addition to the required exits to assist occupants to evacuate a building safely, the type, number, location and fire-isolation must be appropriate to—\nthe travel distance to the lift; and\nthe number, mobility and other characteristics of occupants; and\nthe function or use of the building; and\nthe number of storeys connected by the lift; and\nthe fire safety system installed in the building; and\nthe waiting time, travel time and capacity of the lift; and\nthe reliability and availability of the lift; and\nthe emergency procedures for the building.","g":"/ncc/d1p7","a19":["DP7"]},{"c":"D1P8","t":"Carparking for people with a disability","p":"Part D1 Access and egress","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d1-access-and-egress#D1P8","x":"Carparking spaces for use by people with a disability must be—\nprovided, to the degree necessary, to give equitable access for carparking; and\ndesignated and easy to find.\nLimitations\nD1P8 does not apply to a building where—\na parking service is provided; and\ndirect access to any carparking spaces by the general public or occupants is not available.","g":"/ncc/d1p8","a19":["DP8"]},{"c":"D1P9","t":"Communication systems for people with hearing impairment","p":"Part D1 Access and egress","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d1-access-and-egress#D1P9","x":"An inbuilt communication system for entry, information, entertainment, or for the provision of a service, must be suitable for occupants who are deaf or hearing impaired.\nLimitations\nD1P9 does not apply to—\na Class 4 part of a building; or\nan inbuilt communication system used only for emergency warning purposes.","g":"/ncc/d1p9","a19":["DP9"]},{"c":"D1P10","t":"Wayfinding","p":"Part D1 Access and egress","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d1-access-and-egress#D1P10","x":"Wayfinding signage must be provided in a building to the degree necessary to assist egress and emergency services personnel activities appropriate to—\nthe height of the building; and\nthe number of below ground storeys.","g":"/ncc/d1p10"},{"c":"D1V1","t":"Wire barriers","p":"Part D1 Access and egress","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d1-access-and-egress#D1V1","x":"Compliance with D1P3(2)(c) and (d) for wire barriers is verified when the wire barrier passes the test described below:\nApplication — the test must be carried out on either—\na prototype of a wire barrier that is identical to that proposed to be installed on-site; or\na wire barrier installed on-site.\nTest equipment — the test equipment must consist of the following:\nA horizontally suspended 125 mm diameter, 405 mm long cylinder of 1 mm thick steel having a highly polished 105 mm long cone at one end with a 20 mm diameter flat leading edge to which an eye bolt is fixed.\nA sufficiently flexible horizontal cable with mechanisms capable of applying and measuring a tension of 150 N (or a 15.3 kg weight suspended over a low friction pulley) is to be attached to the eye bolt (see Figure D1V1).\nA mechanism capable of measuring the tension force applied to each wire.\nTest procedure — the test procedure must be as follows:\nTension the wires, within their safe load, to the same tension in all wires and measure the tensions with a strain indicator.\nFor—\nhorizontal or near horizontal wires, position the cone against a pair of wires at the mid-span between supports, then apply the 150 N tension force to the cone; and\nvertical wires, position the cone against a pair of wires at the mid-span between supporting rails, then apply the 150 N tension force to the cone; and\nnear-vertical wires, position the cone against a pair of wires at the widest opening between the wires, then apply the 150 N tension force to the cone.\nAttempt to pull the cone through the gap between the wires under the 150 N load, and—\nincrease the tension in the wires and repeat (ii) until such time as the cone will not pull through; or\nif it does not pull through, reduce the tension in the wires and repeat step (ii); and\nWhen the cone is just prevented from pulling through the gap, the wires are at the correct tension in which case the cone is withdrawn and the tension recorded.\nReduce the tension in the wires and repeat steps (ii) to (iv) twice more, recording the tension in each case after the cone has been removed and then calculate the average of the three tensions as the required tension for each wire.\nFor prototype tests of horizontal or near horizontal wires, record the deflection of each wire at the average tension calculated in accordance with (v) when a 2 kg mass is hung at mid-span between supports.\nTest report — the test report must include the following information:\nThe name and address of the person supervising the test.\nThe test report number.\nThe date of the test.\nThe wire manufacturer’s name and address, and specifications of the wires used in the test including the safe load limit of the wires.\nThe construction details of the test specimen, including a description and drawings and details of the components including supports, post or railing spacings and wire spacings.\nFor a prototype test, the required tension calculated in accordance with (c)(v).\nFor prototype tests of horizontal or near horizontal wires, the deflection measured in accordance with (c)(vi).\nFigure D1V1 Apparatus for testing wire barriers","g":"/ncc/d1v1","a19":["DV1"]},{"c":"D1V2","t":"Access to and within a building","p":"Part D1 Access and egress","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d1-access-and-egress#D1V2","x":"Compliance with D1P1, D1P2, D1P6, E3P4 and/or F4P1, for access, is verified when it is determined that the proposed building provides an equivalent level of access as a reference building when using the following process:\nA performance-based design brief is completed to define the following:\nThe occupant profile and characteristics based on the type and use of the building.\nThe appropriate method for determining the level of access.\nThe appropriate modelling method and tool.\nThe measurable acceptance criteria.\nUsing the appropriate method, the level of access required is determined by first modelling a reference building using the relevant Deemed-to-Satisfy Provisions of Sections D, E and F and the occupant profile and characteristics to determine the—\nneeds of the occupants that the reference building addresses; and\nfacilities required to be accessed by each occupant profile; and\nbaseline measurable acceptance criteria.\nThe proposed building and access solution must be modelled using a modelling method and approach consistent with that used for the reference building, and the same critical features including the following:\nOccupant profile and characteristics.\nBuilding location and orientation.\nLocations of all entrances and exits.\nLocations of facilities important to the solution, including sanitary facilities, lifts, stairwells, etc.\nThe number and range of facilities.\nThe proposed solution’s level of access is assessed by modelling occupant performance using characteristics, whereby the proposed building provides for equivalent access appropriate to the needs of each occupant profile.","g":"/ncc/d1v2","a19":["DV2"]},{"c":"Table D1V3","t":"Ramp crossfall, surface profile and slip resistance","p":"Part D1 Access and egress","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d1-access-and-egress#_22be151f-c7c0-4382-a988-5d5c1f276665","x":"Gradient | Crossfall | Surface profile (mm) | Slip resistance\n1:14 | 1:40 | 2 | P4/R11\n1:12 | 1:50 | 2 | P5/R12\n1:10 | 1:100 | 1 | P5/R12\n1:8 | 1:100 | 0.5 | P5/R12","tb":"D1V3","g":"/ncc/table-d1v3"},{"c":"D1V3","t":"Ramp gradient, crossfall, surface profile and slip resistance for ramps used by wheelchairs","p":"Part D1 Access and egress","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d1-access-and-egress#D1V3","x":"(1) Compliance with Performance Requirement D1P2, relating to gradient, crossfall, surface profile and slip resistance of a ramp for the use of wheelchairs is verified when—\nthe ramp has a gradient that is not steeper than 1:8; and\nthe pushing force required to accelerate a wheelchair and user during ascent is in accordance with (2); and\nthe required braking force for a wheelchair and user during descent is in accordance with (3); and\nthe projected ascent time is in accordance with (4); and\nthe ramp crossfall, surface profile and slip resistance is in accordance with (5).\n(2) The pushing force during ascent must be in accordance with the formula:\n[formula] where—\n[formula] = the maximum force during ascent, equal to 40 N for ramps required to be usable by the general public; and\n[formula] = the design mass of the wheelchair and wheelchair user, equal to 127 kg for ramps required to be usable by the general public; and\n[formula] = the gravitational constant, equal to 9.8 m/s2; and\n[formula] = the angle of incline of the ramp; and\n[formula] = the coefficient of rolling resistance between the wheelchair wheel and the ramp surface, for the rear wheels and front wheels respectively; and\n[formula] = the normal force between the wheelchair wheels and ramp surface, for rear wheels and front wheels respectively.\n(3) The braking force during descent must be less than 9 N when calculated in accordance with the formula:\n[formula] where—\n[formula] = the braking force during descent; and\n[formula] = the design mass of the wheelchair and wheelchair user, equal to 127 kg for ramps required to be usable by the general public; and\n[formula] = the gravitational constant, equal to 9.8 m/s2; and\n[formula] = the angle of incline of the ramp; and\n[formula] = the coefficient of rolling resistance between the wheelchair wheel and ramp surface, for the rear wheels and front wheels respectively; and\n[formula] = the normal force between the wheelchair wheels and ramp surface, for the rear wheels and front wheels respectively.\n(4) The time taken to ascend the ramp must be less than 17 s when calculated in accordance with the formula:\n[formula] where—\n[formula] = the time taken to ascend the ramp in seconds; and\n[formula] = the length of the ramp in metres; and\n[formula] = the design mass of the wheelchair and wheelchair user, equal to 127 kg for ramps required to be useable by the general public; and\n[formula] = the time taken for the wheelchair to achieve maximum velocity, equal to 0.8 m/s; and\n[formula] = the maximum pushing force during ascent, equal to 40 N for ramps required to be usable by the general public; and\n[formula] = the gravitational constant, equal to 9.8 m/s2; and\n[formula] = the angle of incline of the ramp; and\n[formula] = the coefficient of rolling resistance between the wheelchair wheel and ramp surface, for the rear wheels and front wheels respectively; and\n[formula] = the normal force between wheelchair wheels and ramp surface, for the rear wheels and front wheels respectively.\n(5) The crossfall must be no steeper than, the surface profile must be no rougher than, and the slip resistance must be no less than, the values nominated in Table D1V3 for the gradient of the ramp.\nTable D1V3 Ramp crossfall, surface profile and slip resistance\nGradient\nCrossfall\nSurface profile (mm)\nSlip resistance\n1:14\n1:40\n2\nP4/R11\n1:12\n1:50\n2\nP5/R12\n1:10\n1:100\n1\nP5/R12\n1:8\n1:100\n0.5\nP5/R12","g":"/ncc/d1v3","a19":["DV3"]},{"c":"D1V4","t":"Fire Safety Verification Method","p":"Part D1 Access and egress","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d1-access-and-egress#D1V4","x":"Compliance with D1P4, D1P5, D1P6 and D1P7 is verified when a building is designed in accordance with C1V4.","g":"/ncc/d1v4","a19":["DV4"]},{"c":"D2D1","t":"Deemed-to-Satisfy Provisions","p":"Part D2 Provision for escape","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d2-provision-escape#D2D1","x":"(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements D1P1 to D1P6, D1P8 and D1P10 are satisfied by complying with—\nD2D2 to D2D23, D3D2 to D3D31 and D4D2 to D4D13; and\nin a building containing an atrium, Part G3; and\nin a building in an alpine area, Part G4; and\nfor a building containing an occupiable outdoor area, Part G6; and\nfor additional requirements for Class 9b buildings, Part I1; and\nfor public transport buildings, Part I2; and\nfor farm sheds, Part I3.\n(2) Where a Performance Solution is proposed, the relevant Performance Requirements must be determined in accordance with A2G2(3) and A2G4(3) as applicable.\n(3) Performance Requirement D1P7 must be complied with if lifts are to be used to assist occupants to evacuate a building.\nNotes\nThere are no Deemed-to-Satisfy Provisions for D1P7 in respect of using lifts to assist occupants to evacuate a building.","g":"/ncc/d2d1","a19":["D1.0"]},{"c":"D2D2","t":"Application of Part","p":"Part D2 Provision for escape","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d2-provision-escape#D2D2","x":"The Deemed-to-Satisfy Provisions of this Part do not apply to the internal parts of a sole-occupancy unit in a Class 2 or 3 building or a Class 4 part of a building.","g":"/ncc/d2d2","a19":["D1.1"]},{"c":"D2D3","t":"Number of exits required","p":"Part D2 Provision for escape","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d2-provision-escape#D2D3","x":"(1) All buildings — Every building must have at least one exit from each storey.\n(2) Class 2 to 8 buildings —\nIn addition to any horizontal exit, not less than 2 exits must be provided from the following:\nEach storey if the building has an effective height of more than 25 m.\nA Class 2 or 3 building subject to C2D6.\nThe requirements of (a)(i) do not apply to a part of a storey that—\nis provided with direct egress to a road or open space; and\nsatisfies D2D5 by the provision of 1 exit.\n(3) Basements — In addition to any horizontal exit, not less than 2 exits must be provided from any storey if egress from that storey involves a vertical rise within the building of more than 1.5 m, unless—\nthe floor area of the storey is not more than 50 m²; and\nthe distance of travel from any point on the floor to a single exit is not more than 20 m.\n(4) Class 9 buildings —\nIn addition to any horizontal exit, not less than 2 exits must be provided from the following:\nEach storey if the building has a rise in storeys of more than 6 or an effective height of more than 25 m.\nAny storey which includes a patient care area in a Class 9a health-care building.\nAny storey that contains sleeping areas in a Class 9c building.\nAny storey used as a Class 9b early childhood centre, or any Class 9b early childhood centre which forms part of a storey.\nEach storey in a primary or secondary school with a rise in storeys of 2 or more.\nAny storey or mezzanine that accommodates more than 50 persons, calculated under D2D18.\nThe requirements of (a) do not apply to a part of a storey that—\nis a plant room, machinery room, storeroom, lift-machine room or the like; and\nis provided with direct egress to a road, open space or a fire-isolated exit complying with D2D12(2); and\nsatisfies D2D5 by the provision of 1 exit.\n(5) Exits from Class 9c buildings and patient care areas in Class 9a health-care buildings — In a Class 9a health-care building and a Class 9c building, at least one exit must be provided from every part of a storey which has been divided into fire compartments in accordance with C3D3 or C3D6.\n(6) Exits in open spectator stands — In an open spectator stand containing more than one tier of seating, every tier must have not less than 2 stairways or ramps, each forming part of the path of travel to not less than 2 exits.\n(7) Access to exits — Without passing through another sole-occupancy unit every occupant of a storey or part of a storey must have access to—\nan exit; or\nat least 2 exits if 2 or more exits are required.","g":"/ncc/d2d3","a19":["D1.2"]},{"c":"D2D4","t":"When fire-isolated stairways and ramps are required","p":"Part D2 Provision for escape","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d2-provision-escape#D2D4","x":"(1) Class 2 and 3 buildings — The following applies:\nSubject to (b), every stairway or ramp serving as a required exit must be fire-isolated unless it connects, passes through or passes by not more than—\n3 consecutive storeys in a Class 2 building; or\n2 consecutive storeys in a Class 3 building.\nNotwithstanding (a), one extra storey of any classification may be included if—\nit is only for the accommodation of motor vehicles or for other ancillary purposes; or\nthe building has a sprinkler system (other than a FPAA101D system) complying with Specification 17 installed throughout; or\nthe required exit does not provide access to or egress for, and is separated from, the extra storey by construction having—\nan FRL of –/60/60, if non-load bearing; and\nan FRL of 90/90/90, if load bearing; and\nno opening that could permit the passage of fire or smoke.\n(2) Class 5, 6, 7, 8 or 9 buildings — Every stairway or ramp serving as a required exit must be fire-isolated unless—\nin a Class 9a health-care building — it connects, or passes through or passes by not more than 2 consecutive storeys in areas other than patient care areas; or\nit is part of an open spectator stand; or\nin any other case, except in a Class 9b early childhood centre or a Class 9c building, it connects, passes through or passes by not more than 2 consecutive storeys and one extra storey of any classification may be included if—\nthe building has a sprinkler system (other than a FPAA101D system) complying with Specification 17 installed throughout; or\nthe required exit does not provide access to or egress for, and is separated from, the extra storey by construction having—\nan FRL of –/60/60, if non-load bearing; and\nan FRL of 90/90/90 for Type A construction or 60/60/60 for Type B or C construction, if load bearing; and\nno opening that could permit the passage of fire or smoke.\nExemptions\nD2D4(2) does not apply to—\na Class 9b early childhood centre wholly within a storey that provides direct egress to a road or open space; or\na Class 9b early childhood centre with a rise in storeys of not more than 2, where the Class 9b early childhood centre is the only use in that building.","g":"/ncc/d2d4","a19":["D1.3"]},{"c":"D2D5","t":"Exit travel distances","p":"Part D2 Provision for escape","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d2-provision-escape#D2D5","x":"(1) Class 2 and 3 buildings —\nThe entrance doorway of any sole-occupancy unit must be not more than—\n6 m from an exit or from a point from which travel in different directions to 2 exits is available; or\n20 m from a single exit serving the storey at the level of egress to a road or open space; and\nno point on the floor of a room which is not in a sole-occupancy unit must be more than 20 m from an exit or from a point at which travel in different directions to 2 exits is available.\n(2) Class 4 parts of a building — The entrance doorway to any Class 4 part of a building must be not more than 6 m from an exit or a point from which travel in different directions to 2 exits is available.\n(3) Class 5, 6, 7, 8 or 9 buildings — Subject to (4), (5) and (6)—\nno point on a floor must be more than 20 m from an exit, or a point from which travel in different directions to 2 exits is available, in which case the maximum distance to one of those exits must not exceed 40 m; and\nin a Class 5 or 6 building, the distance to a single exit serving a storey at the level of access to a road or open space may be increased to 30 m.\n(4) Class 9a buildings — In a patient care area in a Class 9a building—\nno point on the floor must be more than 12 m from a point from which travel in different directions to 2 of the required exits is available; and\nthe maximum distance to one of those exits must not be more than 30 m from the starting point.\n(5) Open spectator stands — The distance of travel to an exit in a Class 9b building used as an open spectator stand must be not more than 60 m.\n(6) Assembly buildings — In a Class 9b building other than a school or early childhood centre, the distance to one of the exits may be 60 m if—\nthe path of travel from the room concerned to that exit is through another area which is a corridor, hallway, lobby, ramp or other circulation space; and\nthe room is smoke-separated from the circulation space by construction having an FRL of not less than 60/60/60 with every doorway in that construction protected by a tight fitting, self-closing, solid-core door not less than 35 mm thick; and\nthe maximum distance of travel does not exceed 40 m within the room and 20 m from the doorway to the room through the circulation space to the exit.","g":"/ncc/d2d5","a19":["D1.4"]},{"c":"D2D6","t":"Distance between alternative exits","p":"Part D2 Provision for escape","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d2-provision-escape#D2D6","x":"Exits that are required as alternative means of egress must be—\ndistributed as uniformly as practicable within or around the storey served and in positions where unobstructed access to at least 2 exits is readily available from all points on the floor including lift lobby areas; and\nnot less than 9 m apart; and\nnot more than—\nin a Class 2 or 3 building — 45 m apart; or\nin a Class 9a health-care building, if such required exit serves a patient care area — 45 m apart; or\nin all other cases — 60 m apart; and\nlocated so that alternative paths of travel do not converge such that they become less than 6 m apart.","g":"/ncc/d2d6","a19":["SA D1.5(e)","D1.5"]},{"c":"D2D7","t":"Height of exits, paths of travel to exits and doorways","p":"Part D2 Provision for escape","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d2-provision-escape#D2D7","x":"In a required exit or path of travel to an exit the unobstructed height throughout must be not less than 2 m, except the unobstructed height of any doorway may be reduced to not less than 1980 mm.","g":"/ncc/d2d7","a19":["D1.6(a)"]},{"c":"D2D8","t":"Width of exits and paths of travel to exits","p":"Part D2 Provision for escape","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d2-provision-escape#D2D8","x":"(1) The unobstructed width of each required exit or path of travel to an exit, except for ladders provided in accordance with D2D21, D3D23 or I3D5, and doorways, must be not less than—\n1 m; or\n1.8 m in a passageway, corridor or ramp normally used for the transportation of patients in beds within a treatment area or ward area; and\nin a public corridor in a Class 9c aged care building, notwithstanding (2) and (3)—\n1.5 m; and\n1.8 m for the full width of the doorway, providing access into a sole-occupancy unit or communal bathroom.\n(2) If a fire compartment relying on one or more horizontal exits, a storey, a mezzanine or an open spectator stand accommodates more than 100 persons but not more than 200 persons, the aggregate unobstructed width of required exits or paths of travel to an exit, except for doorways, must be not less than—\n1 m plus 250 mm for each 25 persons (or part) in excess of 100; or\n1.8 m in a passageway, corridor or ramp normally used for the transportation of patients in beds within a treatment area or ward area.\n(3) If a fire compartment relying on one or more horizontal exits, a storey, a mezzanine or an open spectator stand accommodates more than 200 persons, the aggregate unobstructed width of required exits or paths of travel to an exit, except for doorways, must be not less than—\n2 m plus 500 mm for every 60 persons (or part) in excess of 200 persons if egress involves a change in floor level by a stairway or ramp with a gradient steeper than 1 in 12; or\nin any other case, 2 m plus 500 mm for every 75 persons (or part) in excess of 200.\n(4) In an open spectator stand which accommodates more than 2000 persons, the aggregate unobstructed width of required exits or paths of travel to an exit, except for doorways, must be not less than 17 m plus a width (in metres) equal to the number in excess of 2000 divided by 600.","g":"/ncc/d2d8","a19":["D1.6(b)","(c)","(d) and (e)"]},{"c":"D2D9","t":"Width of doorways in exits or paths of travel to exits","p":"Part D2 Provision for escape","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d2-provision-escape#D2D9","x":"In a required exit or path of travel to an exit, the unobstructed width of a doorway must be not less than—\nin patient care areas through which patients would normally be transported in beds—\nif the doorway provides access to, or from, a corridor of width—\nless than 2.2 m — 1200 mm; or\n2.2 m or greater — 1070 mm; and\nwhere the doorway referred to in (i) is fitted with two leaves and one leaf is secured in the closed position in accordance with D3D26(3)(e), the other leaf must permit an unobstructed opening not less than 800 mm wide; or\nin patient care areas in a horizontal exit — 1250 mm; or\nthe unobstructed width of each exit provided to comply with D2D8, minus 250 mm; or\nin a Class 9c building, 800 mm, except—\nin resident use areas the minimum unobstructed width must be 870 mm; and\nfor doorways leading from a public corridor to a sole-occupancy unit the minimum unobstructed width must be 1070 mm; and\nwhere the doorway is fitted with two leaves and one leaf is secured in the closed position in accordance with D3D26(3)(e), the other leaf must permit an unobstructed opening not less than 870 mm wide in resident use areas and 800 mm wide in non-resident use area; or\nin any other case except where it opens to a sanitary compartment or bathroom — 750 mm wide.","g":"/ncc/d2d9","a19":["VIC D1.6(f)(iv)","D1.6","NSW D1.6(f)(vi)","D1.6(f)"]},{"c":"D2D10","t":"Exit width not to diminish in direction of travel","p":"Part D2 Provision for escape","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d2-provision-escape#D2D10","x":"The unobstructed width of a required exit must not diminish in the direction of travel to a road or open space, except where the width is increased in accordance with D2D8(1)(b) or D2D9(a)(i).","g":"/ncc/d2d10","a19":["D1.6(g)"]},{"c":"D2D11","t":"Determination and measurement of exits and paths of travel to exits","p":"Part D2 Provision for escape","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d2-provision-escape#D2D11","x":"For the purposes of D2D7 to D2D10 the following apply:\nThe required width of a stairway or ramp in a required exit or path of travel to an exit must—\nbe measured clear of all obstructions such as handrails, projecting parts of barriers and the like; and\nextend without interruption, except for ceiling cornices, to a height not less than 2 m vertically above a line along the nosings of the treads or the floor surface of the ramp or landing.\nTo determine the aggregate unobstructed width, the number of persons accommodated must be calculated according to D2D18.","g":"/ncc/d2d11","a19":["D1.6(h) and (i)"]},{"c":"D2D12","t":"Travel via fire-isolated exits","p":"Part D2 Provision for escape","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d2-provision-escape#D2D12","x":"(1) A doorway from a room must not open directly into a stairway, passageway or ramp that is required to be fire-isolated unless it is from—\na public corridor, public lobby or the like; or\na sole-occupancy unit occupying all of a storey; or\na sanitary compartment, airlock or the like.\n(2) Each fire-isolated stairway or fire-isolated ramp must provide independent egress from each storey served and discharge directly, or by way of its own fire-isolated passageway —\nto a road or open space; or\nto a point—\nin a storey or space, within the confines of the building, that is used only for pedestrian movement, car parking or the like and is open for at least ⅔ of its perimeter; and\nfrom which an unimpeded path of travel, not further than 20 m, is available to a road or open space; or\ninto a covered area that—\nadjoins a road or open space; and\nis open for at least ⅓ of its perimeter; and\nhas an unobstructed clear height throughout, including the perimeter openings, of not less than 3 m; and\nprovides an unimpeded path of travel from the point of discharge to the road or open space of not more than 6 m.\n(3) Where a path of travel from the point of discharge of a fire-isolated exit necessitates passing within 6 m of any part of an external wall of the same building, measured horizontally at right angles to the path of travel, the following applies:\nThat part of the wall must have—\nan FRL of not less than 60/60/60; and\nany openings protected internally in accordance with C4D5; and\nThe protection required by (a) must extend for a distance of 3 m above or below, as appropriate, the level of the path of travel, or for the height of the wall, whichever is the lesser.\n(4) If more than 2 access doorways, not from a sanitary compartment or the like, open to a required fire-isolated exit in the same storey —\na smoke lobby in accordance with D3D7 must be provided; or\nthe exit must be pressurised in accordance with AS 1668.1.\n(5) A ramp must be provided at any change in level less than 600 mm in a fire-isolated passageway in a Class 9 building.","g":"/ncc/d2d12","a19":["D1.7"]},{"c":"D2D13","t":"External stairways or ramps in lieu of fire-isolated exits","p":"Part D2 Provision for escape","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d2-provision-escape#D2D13","x":"(1) An external stairway or ramp may serve as a required exit in lieu of a fire-isolated exit serving a storey below an effective height of 25 m, if the stairway or ramp is—\nnon-combustible throughout; and\nprotected in accordance with (3) if it is within 6 m of, and exposed to, any part of the external wall of the building it serves.\n(2) For the purposes of this clause—\nexposure under (1)(b), is measured in accordance with S5C2, as if the exit was a building element and the external wall of the building was a fire-source feature to the exit, except that the FRL required in S5C2(1)(a) must not be less than 60/60/60; and\nthe plane formed at the construction edge or perimeter of an unenclosed building or part such as an open-deck carpark, open spectator stand or the like, is deemed to be an external wall; and\nopenings in an external wall and openings under (3) and (4), are determined in accordance with C4D2.\n(3) The protection referred to in (1)(b), must adequately protect occupants using the exit from exposure to a fire within the building, in accordance with one of the following methods:\nThe part of the external wall of the building to which the exit is exposed must have—\nan FRL of not less than 60/60/60; and\nno openings less than 3 m from the exit (except a doorway serving the exit protected by a –/60/30 fire door in accordance with C4D9(1)); and\nany opening 3 m or more but less than 6 m from the exit, protected in accordance with C4D5 and if wall wetting sprinklers are used, they are located internally.\nThe exit must be protected by construction of a wall, roof, floor or other shielding element as appropriate in accordance with (4) from—\nany part of the external wall of the building having an FRL of less than 60/60/60; and\nany openings in the external wall.\n(4) The wall, roof, floor or other shielding element required by (3)(b) must—\nhave an FRL of not less than 60/60/60; and\nhave no openings less than 3 m from the external wall of the building (except a doorway serving the exit protected by a –/60/30 fire door in accordance with C4D9(1)); and\nhave any opening 3 m or more but less than 6 m from any part of the external wall of the building protected in accordance with C4D5 and if wall wetting sprinklers are used, they are located on the side exposed to the external wall.","g":"/ncc/d2d13","a19":["D1.8"]},{"c":"D2D14","t":"Travel by non-fire-isolated stairways or ramps","p":"Part D2 Provision for escape","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d2-provision-escape#D2D14","x":"(1) A non-fire-isolated stairway or non-fire-isolated ramp serving as a required exit must provide a continuous means of travel by its own flights and landings from every storey served to the level at which egress to a road or open space is provided.\n(2) In a Class 2, 3 or 4 building, the distance between the doorway of a room or sole-occupancy unit and the point of egress to a road or open space by way of a stairway or ramp that is not fire-isolated and is required to serve that room or sole-occupancy unit must not exceed—\n30 m in a building of Type C construction; or\n60 m in all other cases.\n(3) In a Class 5, 6, 7, 8 or 9 building, the distance from any point on a floor to a point of egress to a road or open space by way of a required non-fire-isolated stairway or non-fire-isolated ramp must not exceed 80 m.\n(4) In a Class 2, 3 or 9a building, a required non-fire-isolated stairway or non-fire-isolated ramp must discharge at a point not more than—\n15 m from a doorway providing egress to a road or open space or from a fire-isolated passageway leading to a road or open space; or\n30 m from one of 2 such doorways or passageways if travel to each of them from the non-fire-isolated stairway or non-fire-isolated ramp is in opposite or approximately opposite directions.\n(5) In a Class 5 to 8 or 9b building, a required non-fire-isolated stairway or non-fire-isolated ramp must discharge at a point not more than—\n20 m from a doorway providing egress to a road or open space or from a fire-isolated passageway leading to a road or open space; or\n40 m from one of 2 such doorways or passageways if travel to each of them from the non-fire-isolated stairway or non-fire-isolated ramp is in opposite or approximately opposite directions.\n(6) In a Class 2 or 3 building, if 2 or more exits are required and are provided by means of internal non-fire-isolated stairways or non-fire-isolated ramps each exit must—\nprovide separate egress to a road or open space; and\nbe suitably smoke-separated from each other at the level of discharge.","g":"/ncc/d2d14","a19":["D1.9"]},{"c":"D2D15","t":"Discharge from exits","p":"Part D2 Provision for escape","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d2-provision-escape#D2D15","x":"(1) An exit must not be blocked at the point of discharge and where necessary, suitable barriers must be provided to prevent vehicles from blocking the exit, or access to it.\n(2) If a required exit leads to an open space, the path of travel to the road must have an unobstructed width throughout of not less than—\nthe minimum width of the required exit; or\n1 m,\nwhichever is the greater.\n(3) If an exit discharges to open space that is at a different level than the public road to which it is connected, the path of travel to the road must be by—\na ramp or other incline having a gradient not steeper than 1:8 at any part, or not steeper than 1:14 if required by the Deemed-to-Satisfy Provisions of Part D4; or\nexcept if the exit is from a Class 9a building, a stairway complying with the Deemed-to-Satisfy Provisions of the NCC.\n(4) The discharge point of alternative exits must be located as far apart as practical.\n(5) In a Class 9b building which is an open spectator stand that accommodates more than 500 persons, a required stairway or required ramp must not discharge to the ground in front of the stand.\n(6) In a Class 9b building containing an auditorium which accommodates more than 500 persons, not more than ⅔ of the required width of exits must be located in the main entrance foyer.\n(7) The number of persons accommodated must be calculated according to D2D18.","g":"/ncc/d2d15","a19":["D1.10"]},{"c":"D2D16","t":"Horizontal exits","p":"Part D2 Provision for escape","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d2-provision-escape#D2D16","x":"(1) Horizontal exits must not be counted as required exits —\nbetween sole-occupancy units; or\nin a Class 9b building used as an early childhood centre, primary or secondary school.\n(2) In a Class 9a health-care building or Class 9c building, horizontal exits may be counted as required exits if the path of travel from a fire compartment leads by one or more horizontal exits directly into another fire compartment which has at least one required exit which is not a horizontal exit.\n(3) In cases other than in (2), horizontal exits must not comprise more than half of the required exits from any part of a storey divided by a fire wall.\n(4) Horizontal exits must have a clear area on the side of the fire wall to which occupants are evacuating, to accommodate the total number of persons (calculated under D2D18) served by the horizontal exit of not less than—\n2.5 m2 per patient/resident in a Class 9a health-care building or Class 9c aged care building; and\n0.5 m2 per person in any other case.\n(5) Where a fire compartment is provided with only two exits, and one of those exits is a horizontal exit, the clear area required by (4) is to be of a size that accommodates all the occupants from the fire compartment being evacuated.\n(6) In a Class 9b early childhood centre, the clear area required by (4) must accommodate all occupants of the early childhood centre.\n(7) The clear area required by (4) must be connected to the horizontal exit by an unobstructed path that has at least the dimensions required for the horizontal exit and may include the area of the unobstructed path.\n(8) Each fire compartment required by C3D6(2) must be served by not less than 2 horizontal exits, each located not less than 9 m from—\nat least one other horizontal exit; and\nan exit other than a horizontal exit.","g":"/ncc/d2d16","a19":["D1.11"]},{"c":"D2D17","t":"Non-required stairways, ramps or escalators","p":"Part D2 Provision for escape","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d2-provision-escape#D2D17","x":"An escalator, moving walkway or non-required non fire-isolated stairway or pedestrian ramp—\nmust not be used between storeys in—\na patient care area in a Class 9a health-care building; or\na resident use area in a Class 9c building; and\nmay connect any number of storeys if it is—\nin an open spectator stand or indoor sports stadium; or\nin a carpark or an atrium; or\noutside a building; or\nin a Class 5 or 6 building that is sprinklered throughout, where the escalator, walkway, stairway or ramp complies with Specification 14; and\nexcept where permitted in (b) must not connect more than—\n3 storeys if—\neach of those storeys is provided with a sprinkler system (other than a FPAA101D system) complying with Specification 17 throughout; and\nat least one of those storeys is situated at a level at which there is a direct egress to a road or open space; or\n2 storeys, provided that those storeys are consecutive, and one of the storeys is situated at a level at which there is direct egress to a road or open space; and\nexcept where permitted in (b) or (c), must not connect, directly or indirectly, more than 2 storeys at any level in a Class 5, 6, 7, 8 or 9 building and those storeys must be consecutive.","g":"/ncc/d2d17","a19":["D1.12"]},{"c":"Table D2D18","t":"Area per person according to use","p":"Part D2 Provision for escape","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d2-provision-escape#_50139621-9a55-4f1d-915c-e01bef4288f8","x":"Type of use | Area per person\nArt gallery, exhibition area, museum | 4 m2\nBar — standing | 0.5m2\nBar — other | 1 m2\nBoard room | 2 m2\nBoarding house | 15 m2\nCafe, church, dining room | 1 m2\nCarpark | 30 m2\nComputer room | 25 m2\nCourt room — judicial area | 10 m2\nCourt room — public seating | 1 m2\nDance floor | 0.5 m2\nDormitory | 5 m2\nEarly childhood centre | 4 m2\nFactory — machine shop, fitting shop or like place for cutting, grading, finishing or fitting of metals or glass, except in the fabrication of structural steelwork or manufacture of vehicles or bulky products | 5 m2\nFactory — areas used for fabrication and processing other than a machine shop, fitting shop or the like. | 50 m2\nFactory — a space in which the layout and natural use of fixed plant or equipment determines the number of persons who will occupy the space during working hours | Area per person determined by the use of the plant or equipment\nGymnasium | 3 m2\nHostel, hotel, motel, guest house | 15 m2\nIndoor sports stadium—arena | 10 m2\nKiosk | 1 m2\nKitchen, laboratory, laundry | 10 m2\nLibrary — reading space | 2 m2\nLibrary — storage space | 30 m2\nOffice, including one for typewriting or document copying | 10 m2\nPatient care areas | 10 m2\nPlant room — ventilation, electrical or other service units | 30 m2\nPlant room — boilers or power plant | 50 m2\nReading room | 2 m2\nRestaurant | 1 m2\nSchool — general classroom | 2 m2\nSchool — multi-purpose hall | 1 m2\nSchool — staff room | 10 m2\nSchool — trade and practical area — primary | 4 m2\nSchool — trade and practical area — secondary | As for workshop\nShop — space for sale of goods — at a level entered direct from the open air or any lower level | 3 m2\nShop — space for sale of goods — all other levels | 5 m2\nShowroom — display area, covered mall or arcade | 5 m2\nSkating rink, based on rink area | 1.5 m2\nSpectator stand, audience viewing area — standing viewing area | 0.3 m2\nSpectator stand, audience viewing area — removable seating | 1 m2\nSpectator stand, audience viewing area — fixed seating | Per number of seats\nSpectator stand, audience viewing area — bench seating | 450 mm/person\nStorage space | 30 m2\nSwimming pool, based on pool area | 1.5 m2\nSwitch room, transformer room | 30 m2\nTelephone exchange — private | 30 m2\nTheatre and public hall | 1 m2\nTheatre dressing room | 4 m2\nTransport terminal | 2 m2\nWorkshop — for maintenance staff | 30 m2\nWorkshop — for manufacturing processes | As for factory\nTable Notes\nBar standing is an area used by the standing patrons and extends not less than 1.5 m wide from the outside edge of the bar top for the length of the serving area of the bar.","tb":"D2D18","g":"/ncc/table-d2d18"},{"c":"D2D18","t":"Number of persons accommodated","p":"Part D2 Provision for escape","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d2-provision-escape#D2D18","x":"For the purposes of the Deemed-to-Satisfy Provisions, the number of persons accommodated in a storey, room or mezzanine must be determined with consideration to the purpose for which it is used and the layout of the floor area by—\ncalculating the sum of the numbers obtained by dividing the floor area of each part of the storey by the number of square metres per person listed in Table D2D18 according to the use of that part, excluding spaces set aside for—\nlifts, stairways, ramps and escalators, corridors, hallways, lobbies and the like; and\nservice ducts and the like, sanitary compartments or other ancillary uses; or\nreference to the seating capacity in an assembly building or room; or\nany other suitable means of assessing its capacity.\nTable D2D18 Area per person according to use\nType of use\nArea per person\nArt gallery, exhibition area, museum\n4 m2\nBar — standing\n0.5m2\nBar — other\n1 m2\nBoard room\n2 m2\nBoarding house\n15 m2\nCafe, church, dining room\n1 m2\nCarpark\n30 m2\nComputer room\n25 m2\nCourt room — judicial area\n10 m2\nCourt room — public seating\n1 m2\nDance floor\n0.5 m2\nDormitory\n5 m2\nEarly childhood centre\n4 m2\nFactory — machine shop, fitting shop or like place for cutting, grading, finishing or fitting of metals or glass, except in the fabrication of structural steelwork or manufacture of vehicles or bulky products\n5 m2\nFactory — areas used for fabrication and processing other than a machine shop, fitting shop or the like.\n50 m2\nFactory — a space in which the layout and natural use of fixed plant or equipment determines the number of persons who will occupy the space during working hours\nArea per person determined by the use of the plant or equipment\nGymnasium\n3 m2\nHostel, hotel, motel, guest house\n15 m2\nIndoor sports stadium—arena\n10 m2\nKiosk\n1 m2\nKitchen, laboratory, laundry\n10 m2\nLibrary — reading space\n2 m2\nLibrary — storage space\n30 m2\nOffice, including one for typewriting or document copying\n10 m2\nPatient care areas\n10 m2\nPlant room — ventilation, electrical or other service units\n30 m2\nPlant room — boilers or power plant\n50 m2\nReading room\n2 m2\nRestaurant\n1 m2\nSchool — general classroom\n2 m2\nSchool — multi-purpose hall\n1 m2\nSchool — staff room\n10 m2\nSchool — trade and practical area — primary\n4 m2\nSchool — trade and practical area — secondary\nAs for workshop\nShop — space for sale of goods — at a level entered direct from the open air or any lower level\n3 m2\nShop — space for sale of goods — all other levels\n5 m2\nShowroom — display area, covered mall or arcade\n5 m2\nSkating rink, based on rink area\n1.5 m2\nSpectator stand, audience viewing area — standing viewing area\n0.3 m2\nSpectator stand, audience viewing area — removable seating\n1 m2\nSpectator stand, audience viewing area — fixed seating\nPer number of seats\nSpectator stand, audience viewing area — bench seating\n450 mm/person\nStorage space\n30 m2\nSwimming pool, based on pool area\n1.5 m2\nSwitch room, transformer room\n30 m2\nTelephone exchange — private\n30 m2\nTheatre and public hall\n1 m2\nTheatre dressing room\n4 m2\nTransport terminal\n2 m2\nWorkshop — for maintenance staff\n30 m2\nWorkshop — for manufacturing processes\nAs for factory\nTable Notes\nBar standing is an area used by the standing patrons and extends not less than 1.5 m wide from the outside edge of the bar top for the length of the serving area of the bar.","g":"/ncc/d2d18","a19":["D1.13"]},{"c":"D2D19","t":"Measurement of distances","p":"Part D2 Provision for escape","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d2-provision-escape#D2D19","x":"The nearest part of an exit means in the case of—\na fire-isolated stairway, fire-isolated passageway, or fire-isolated ramp, the nearest part of the doorway providing access to them; and\na non-fire-isolated stairway, the nearest part of the nearest riser; and\na non-fire-isolated ramp, the nearest part of the junction of the floor of the ramp and the floor of the storey; and\na doorway opening to a road or open space, the nearest part of the doorway; and\na horizontal exit, the nearest part of the doorway.","g":"/ncc/d2d19","a19":["D1.14"]},{"c":"D2D20","t":"Method of measurement","p":"Part D2 Provision for escape","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d2-provision-escape#D2D20","x":"The following rules apply:\nIn the case of a room that is not a sole-occupancy unit in a Class 2 or 3 building or Class 4 part of a building, the distance includes the straight-line measurement from any point on the floor of the room to the nearest part of a doorway leading from it, together with the distance from that part of the doorway to the single required exit or point from which travel in different directions to 2 required exits is available.\nSubject to (d), the distance from the doorway of a sole-occupancy unit in a Class 2 or 3 building or a Class 4 part of a building is measured in a straight line to the nearest part of the required single exit or point from which travel in different directions to 2 required exits is available.\nSubject to (d), the distance between exits is measured in a straight line between the nearest parts of those exits.\nOnly the shortest distance is taken along a corridor, hallway, external balcony or other path of travel that curves or changes direction.\nIf more than one corridor, hallway, or other internal path of travel connects required exits, for the purposes of D2D6(c) the measurement is along the path of travel through the point at which travel in different directions to those exits is available, as determined in accordance with D2D5.\nIf a wall (including a demountable internal wall) that does not bound a room, corridor, hallway or the like causes a change of direction in proceeding to a required exit, the distance is measured along the path of travel past that wall.\nIf permanent fixed seating is provided, the distance is measured along the path of travel between the rows of seats.\nIn the case of a non-fire-isolated stairway or non-fire-isolated ramp, the distance is measured along a line connecting the nosings of the treads, or along the slope of the ramp, together with the distance connecting those lines across any intermediate landings.","g":"/ncc/d2d20","a19":["D1.15"]},{"c":"D2D21","t":"Plant rooms, lift machine rooms and electricity network substations: Concession","p":"Part D2 Provision for escape","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d2-provision-escape#D2D21","x":"(1) A ladder may be used in lieu of a stairway to provide egress from—\na plant room with a floor area of not more than 100 m2; or\nall but one point of egress from a plant room, a lift machine room or a Class 8 electricity network substation with a floor area of not more than 200 m2.\n(2) A ladder permitted under (1)—\nmay—\nform part of an exit provided that in the case of a fire-isolated stairway it is contained within the shaft; or\ndischarge within a storey in which case it must be considered as forming part of the path of travel; and\nfor a plant room or a Class 8 electricity network substation, must comply with AS 1657; and\nfor a lift machine room, where access is provided from within a machine room to a secondary floor, a fixed rung type ladder complying with AS 1657 may be used, provided that—\nthe height between the floors is not more than 2800 mm; and\nthe ladder is inclined at an angle to the horizontal not less than 65 degrees nor more than 75 degrees; and\nthe distance between the front face of the ladder and any adjacent obstruction is not less than—\n960 mm, where the ladder is inclined 65 degrees to the horizontal; or\n760 mm, where the ladder is inclined 75 degrees to the horizontal; or\na distance that is determined by interpolating the values in (A) and (B), where the ladder is inclined at any angle between 65 degrees and 75 degrees to the horizontal; and\na clear space not less than 600 mm exists between the foot of the ladder and any equipment.","g":"/ncc/d2d21","a19":["D1.16"]},{"c":"D2D22","t":"Access to lift pits","p":"Part D2 Provision for escape","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d2-provision-escape#D2D22","x":"Access to lift pits must—\nwhere the pit depth is not more than 3 m, be through the lowest landing doors; or\nwhere the pit depth is more than 3 m, be provided through an access doorway complying with the following:\nIn lieu of D2D7 to D2D11, the doorway must be level with the pit floor and not be less than 600 mm wide by 1980 mm high clear opening, which may be reduced to 1500 mm where it is necessary to comply with (ii).\nNo part of the lift car or platform must encroach on the pit doorway entrance when the car is on a fully compressed buffer.\nAccess to the doorway must be by a stairway complying with AS 1657.\nIn lieu of D3D26, doors fitted to the doorway must be—\nof the horizontal sliding or outwards opening hinged type; and\nself-closing and self-locking from the outside; and\nmarked on the landing side with the letters not less than 35 mm high:\nDANGER LIFTWELL – ENTRY OF UNAUTHORIZED PERSONS PROHIBITED – KEEP CLEAR AT ALL TIMES","g":"/ncc/d2d22","a19":["D1.17"]},{"c":"D2D23","t":"Egress from primary schools","p":"Part D2 Provision for escape","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d2-provision-escape#D2D23","x":"(1) Every part of a Class 9b primary school must be wholly within a storey that provides direct egress to a road or open space.\n(2) The requirements of (1) do not apply to a building with a rise in storeys of 4 or less, where the primary school is the only use in that building.\nApplications\nFor D2D23(1), a primary school includes classrooms, offices, staffrooms, halls, canteens and the like within the primary school.\nFor D2D23(2), a primary school includes classrooms, offices, staffrooms, halls, canteens, carparks, end of trip facilities and the like provided solely for the primary school, or school which incorporates the primary school.","g":"/ncc/d2d23","a19":["D1.18"]},{"c":"D3D1","t":"Deemed-to-Satisfy Provisions","p":"Part D3 Construction of exits","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d3-construction-exits#D3D1","x":"(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements D1P1 to D1P6, D1P8 to D1P10 are satisfied by complying with—\nD2D2 to D2D23, D3D2 to D3D31 and D4D2 to D4D13; and\nin a building containing an atrium, Part G3; and\nin a building in an alpine area, Part G4; and\nfor a building containing an occupiable outdoor area, Part G6; and\nfor additional requirements for Class 9b buildings, Part I1; and\nfor public transport buildings, Part I2; and\nfor farm buildings and farm sheds, Part I3.\n(2) Where a Performance Solution is proposed the relevant Performance Requirements must be determined in accordance with A2G2(3) and A2G4(3) as applicable.\n(3) Performance Requirement D1P7 must be complied with if lifts are to be used to assist occupants to evacuate a building.\nNotes\nThere are no Deemed-to-Satisfy Provisions for D1P7 in respect of using lifts to assist occupants to evacuate a building.","g":"/ncc/d3d1","a19":["D2.0"]},{"c":"D3D2","t":"Application of Part","p":"Part D3 Construction of exits","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d3-construction-exits#D3D2","x":"Except for—\nD3D14, D3D15(a), D3D17, D3D18, D3D19, D3D20, D3D21, D3D22(5), D3D22(6), D3D26 and D3D29, the Deemed-to-Satisfy Provisions of this Part do not apply to the internal parts of a sole-occupancy unit in a Class 3 building; and\nD3D14, D3D15(a), D3D17, D3D18, D3D19, D3D20, D3D21, D3D22(5), D3D22(6), D3D23 and D3D29, the Deemed-to-Satisfy Provisions of this Part do not apply to the internal parts of a sole-occupancy unit in a Class 2 building or Class 4 part of a building.","g":"/ncc/d3d2","a19":["NSW D2.1(c)","D2.1"]},{"c":"D3D3","t":"Fire-isolated stairways and ramps","p":"Part D3 Construction of exits","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d3-construction-exits#D3D3","x":"A stairway or ramp (including any landings) that is required to be within a fire-resisting shaft must be constructed—\nof non-combustible materials; and\nso that if there is local failure it will not cause structural damage to, or impair the fire-resistance of, the shaft.","g":"/ncc/d3d3","a19":["D2.2"]},{"c":"D3D4","t":"Non-fire-isolated stairways and ramps","p":"Part D3 Construction of exits","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d3-construction-exits#D3D4","x":"In a building having a rise in storeys of more than 2, required stairs and ramps (including landings and any supporting building elements) which are not required to be within a fire-resisting shaft, must be constructed according to D3D3, or only of—\nreinforced or prestressed concrete; or\nsteel in no part less than 6 mm thick; or\ntimber that—\nhas a finished thickness of not less than 44 mm; and\nhas an average density of not less than 800 kg/m3 at a moisture content of 12%; and\nhas not been joined by means of glue unless it has been laminated and glued with resorcinol formaldehyde or resorcinol phenol formaldehyde glue.","g":"/ncc/d3d4","a19":["D2.3"]},{"c":"D3D5","t":"Separation of rising and descending stair flights","p":"Part D3 Construction of exits","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d3-construction-exits#D3D5","x":"If a stairway serving as an exit is required to be fire-isolated—\nthere must be no direct connection between—\na flight rising from a storey below the lowest level of access to a road or open space; and\na flight descending from a storey above that level; and\nany construction that separates or is common to the rising and descending flights must be—\nnon-combustible; and\nsmoke proof in accordance with S11C2.","g":"/ncc/d3d5","a19":["D2.4"]},{"c":"D3D6","t":"Open access ramps and balconies","p":"Part D3 Construction of exits","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d3-construction-exits#D3D6","x":"Where an open access ramp or balcony is provided to meet the smoke hazard management requirements of E2D4 to E2D13, it must—\nhave ventilation openings to the outside air which—\nhave a total unobstructed area not less than the floor area of the ramp or balcony; and\nare evenly distributed along the open sides of the ramp or balcony; and\nnot be enclosed on its open sides above a height of 1 m except by an open grille or the like having a free air space of not less than 75% of its area.","g":"/ncc/d3d6","a19":["D2.5"]},{"c":"D3D7","t":"Smoke lobbies","p":"Part D3 Construction of exits","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d3-construction-exits#D3D7","x":"A smoke lobby required by D2D12 must—\nhave a floor area not less than 6 m2; and\nbe separated from the occupied areas in the storey by walls which are impervious to smoke, and—\nhave an FRL of not less than 60/60/– (which may be fire-protective grade plasterboard, gypsum block with set plaster, face brickwork, glass blocks or glazing); and\nextend from slab to slab, or to the underside of a ceiling with a resistance to the incipient spread of fire of 60 minutes which covers the lobby; and\nany construction joints between the top of the walls and the floor slab, roof or ceiling must be smoke sealed with intumescent putty or other suitable material; and\nat any opening from the occupied areas, have smoke doors complying with S12C3 and S12C4 except that the smoke sensing device need only be located on the approach side of the opening; and\nbe pressurised as part of the exit if the exit is required to be pressurised under E2D4.","g":"/ncc/d3d7","a19":["D2.6"]},{"c":"D3D8","t":"Installations in exits and paths of travel","p":"Part D3 Construction of exits","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d3-construction-exits#D3D8","x":"(1) Access to service shafts and services other than to fire-fighting or detection equipment as permitted in the Deemed-to-Satisfy Provisions of Section E, must not be provided from a fire-isolated stairway, fire-isolated passageway or fire-isolated ramp.\n(2) An opening to any chute or duct intended to convey hot products of combustion from a boiler, incinerator, fireplace or the like, must not be located in any part of a required exit or any corridor, hallway, lobby or the like leading to a required exit.\n(3) Gas or other fuel services must not be installed in a required exit.\n(4) Except for in a fire-isolated exit specified in (1), services or equipment enclosed in accordance with (5) may be installed in a required exit, or in any corridor, hallway, lobby or the like leading to a required exit, where that service or equipment comprises—\nelectricity meters, distribution boards or ducts; or\ncentral telecommunications distribution boards or equipment; or\nelectrical motors or other motors serving equipment in the building.\n(5) An enclosure for the purposes of (4) must be suitably sealed against smoke spreading from the enclosure and be—\nnon-combustible construction; or\na fire-protective covering.\n(6) Electrical wiring may be installed in a fire-isolated exit if the wiring is associated with—\na lighting, detection, or pressurisation system serving the exit; or\na security, surveillance or management system serving the exit; or\nan intercommunication system or an audible or visual alarm system in accordance with D3D27; or\nthe monitoring of hydrant or sprinkler isolating valves.","g":"/ncc/d3d8","a19":["D2.7"]},{"c":"D3D9","t":"Enclosure of space under stairs and ramps","p":"Part D3 Construction of exits","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d3-construction-exits#D3D9","x":"(1) Fire-isolated stairways and ramps — If the space below a required fire-isolated stairway or fire-isolated ramp is within the fire-isolated shaft, it must not be enclosed to form a cupboard or similar enclosed space.\n(2) Non fire-isolated stairways and ramps — The space below a required non fire-isolated stairway (including an external stairway) or non fire-isolated ramp must not be enclosed to form a cupboard or other enclosed space unless—\nthe enclosing walls and ceilings have an FRL of not less than 60/60/60; and\nany access doorway to the enclosed space is fitted with a self-closing –/60/30 fire door.","g":"/ncc/d3d9","a19":["D2.8"]},{"c":"D3D10","t":"Width of required stairways and ramps","p":"Part D3 Construction of exits","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d3-construction-exits#D3D10","x":"A required stairway or ramp that exceeds 2 m in width is counted as having a width of only 2 m unless it is divided by a handrail or barrier continuous between landings and each division has a width of not more than 2 m.","g":"/ncc/d3d10","a19":["D2.9"]},{"c":"D3D11","t":"Pedestrian ramps","p":"Part D3 Construction of exits","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d3-construction-exits#D3D11","x":"(1) A fire-isolated ramp may be substituted for a fire-isolated stairway if the construction enclosing the ramp and the width and ceiling height comply with the requirements for a fire-isolated stairway.\n(2) A ramp serving as a required exit must—\nwhere the ramp is also serving as an accessible ramp under Part D4, be in accordance with AS 1428.1; or\nin any other case, have a gradient not steeper than 1:8.\n(3) The floor surface of a ramp, other than a threshold ramp, must have a slip-resistance classification not less than that listed in Table D3D15 when tested in accordance with AS 4586.","g":"/ncc/d3d11","a19":["D2.10"]},{"c":"D3D12","t":"Fire-isolated passageways","p":"Part D3 Construction of exits","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d3-construction-exits#D3D12","x":"(1) The enclosing construction of a fire-isolated passageway must have an FRL when tested for a fire outside the passageway in another part of the building of—\nif the passageway discharges from a fire-isolated stairway or ramp — not less than that required for the stairway or ramp shaft; or\nin any other case — not less than 60/60/60.\n(2) Notwithstanding (1)(b), the top construction of a fire-isolated passageway need not have an FRL if the walls of the fire-isolated passageway extend to the underside of—\na non-combustible roof covering; or\na ceiling having a resistance to the incipient spread of fire of not less than 60 minutes separating the roof space or ceiling space in all areas surrounding the passageway within the fire compartment.","g":"/ncc/d3d12","a19":["D2.11"]},{"c":"D3D13","t":"Roof as open space","p":"Part D3 Construction of exits","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d3-construction-exits#D3D13","x":"If an exit discharges to a roof of a building, the roof must—\nhave an FRL of not less than 120/120/120; and\nnot have any roof lights or other openings within 3 m of the path of travel of persons using the exit to reach a road or open space.","g":"/ncc/d3d13","a19":["D2.12"]},{"c":"Table D3D14","t":"Riser and going dimensions","p":"Part D3 Construction of exits","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d3-construction-exits#_259b5062-81ca-4d99-9d02-61f4941a1826","x":"Stairway location | Riser (R) | Going (G)Note 3 | Quantity (2R + G)\nMax | Min | Max | Min | Max | Min\nPublic | 190 | 115 | 355 | 250 | 700 | 550\nPrivate Note 1 | 190 | 115 | 355 | 240 | 700 | 550\nTable Notes\nPrivate stairways are—\nstairways in a sole-occupancy unit in a Class 2 building or Class 4 part of a building; and\nin any building, stairways which are not part of a required exit and to which the public do not normally have access.\nGoing and riser dimensions must be measured in accordance with Figure D3D14.\nThe going in tapered treads (except winders in lieu of a quarter or half landing) in a curved or spiral stairway is measured—\n270 mm in from the outer side of the unobstructed width of the stairway if the stairway is less than 1 m wide (applicable to a non-required stairway only); and\n270 mm from each side of the unobstructed width of the stairway if the stairway is 1 m wide or more.","tb":"D3D14","g":"/ncc/table-d3d14"},{"c":"D3D14","t":"Goings and risers","p":"Part D3 Construction of exits","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d3-construction-exits#D3D14","x":"(1) A stairway must have—\nnot more than 18 and not less than 2 risers in each flight; and\ngoing (G), riser (R) and quantity (2R + G) in accordance with Table D3D14, except as permitted by (2) and (3); and\nconstant goings and risers throughout each flight, except as permitted by (2) and (3), and the dimensions of goings (G) and risers (R) in accordance with (1)(b) are considered constant if the variation between—\nadjacent risers, or between adjacent goings, is no greater than 5 mm; and\nthe largest and smallest riser within a flight, or the largest and smallest going within a flight, does not exceed 10 mm; and\nrisers which do not have any openings that would allow a 125 mm sphere to pass through between the treads; and\ntreads which have—\na surface with a slip-resistance classification not less than that listed in Table D3D15 when tested in accordance with AS 4586; or\na nosing strip with a slip-resistance classification not less than that listed in Table D3D15 when tested in accordance with AS 4586; and\ntreads of solid construction (not mesh or other perforated material) if the stairway is more than 10 m high or connects more than 3 storeys; and\nin a Class 9b building, not more than 36 risers in consecutive flights without a change in direction of at least 30°; and\nin the case of a required stairway, no winders in lieu of a landing.\n(2) In the case of a non-required stairway—\nthe stairway must have—\nnot more than 3 winders in lieu of a quarter landing; and\nnot more than 6 winders in lieu of a half landing; and\nthe going of all straight treads must be constant throughout the same flight and the dimensions of goings (G) is considered constant if the variation between—\nadjacent goings, is no greater than 5 mm; and\nthe largest and smallest going within a flight, does not exceed 10 mm; and\nthe going of all winders in lieu of a quarter or half landing may vary from the going of the straight treads within the same flight provided that the going of all such winders is constant.\n(3) Where a stairway discharges to a sloping public walkway or public road—\nthe riser (R) may be reduced to account for the slope of the walkway or road; and\nthe quantity (2R+G) may vary at that location.\nTable D3D14 Riser and going dimensions\nStairway location\nRiser (R)\nGoing (G)Note 3\nQuantity (2R + G)\nMax\nMin\nMax\nMin\nMax\nMin\nPublic\n190\n115\n355\n250\n700\n550\nPrivate Note 1\n190\n115\n355\n240\n700\n550\nTable Notes\nPrivate stairways are—\nstairways in a sole-occupancy unit in a Class 2 building or Class 4 part of a building; and\nin any building, stairways which are not part of a required exit and to which the public do not normally have access.\nGoing and riser dimensions must be measured in accordance with Figure D3D14.\nThe going in tapered treads (except winders in lieu of a quarter or half landing) in a curved or spiral stairway is measured—\n270 mm in from the outer side of the unobstructed width of the stairway if the stairway is less than 1 m wide (applicable to a non-required stairway only); and\n270 mm from each side of the unobstructed width of the stairway if the stairway is 1 m wide or more.\nFigure D3D14 Riser and going dimensions","g":"/ncc/d3d14","a19":["D2.13"]},{"c":"Table D3D15","t":"Slip-resistance classification","p":"Part D3 Construction of exits","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d3-construction-exits#_c2646c60-7936-4fa3-9fc3-ad7616d1f842","x":"Application | Dry surface conditions | Wet surface conditions\nRamp steeper than 1:14 | P4 or R11 | P5 or R12\nRamp steeper than 1:20 but not steeper than 1:14 | P3 or R10 | P4 or R11\nTread or landing surface | P3 or R10 | P4 or R11\nNosing or landing edge strip | P3 | P4","tb":"D3D15","g":"/ncc/table-d3d15"},{"c":"D3D15","t":"Landings","p":"Part D3 Construction of exits","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d3-construction-exits#D3D15","x":"In a stairway—\nlandings having a maximum gradient of 1:50 may be used in any building to limit the number of risers in each flight and each landing must—\nbe not less than 750 mm long, and where this involves a change in direction, the length is measured 500 mm from the inside edge of the landing; and\nhave—\na surface with a slip-resistance classification not less than that listed in Table D3D15 when tested in accordance with AS 4586; or\na strip at the edge of the landing with a slip-resistance classification not less than that listed in Table D3D15 when tested in accordance with AS 4586, where the edge leads to a flight below; and\nin a Class 9a building—\nthe area of any landing must be sufficient to move a stretcher, 2 m long and 600 mm wide, at a gradient not more than the gradient of the stairs, with at least one end of the stretcher on the landing while changing direction between flights; or\nthe stair must have a change of direction of 180°, and the landing a clear width of not less than 1.6 m and a clear length of not less than 2.7 m.\nTable D3D15 Slip-resistance classification\nApplication\nDry surface conditions\nWet surface conditions\nRamp steeper than 1:14\nP4 or R11\nP5 or R12\nRamp steeper than 1:20 but not steeper than 1:14\nP3 or R10\nP4 or R11\nTread or landing surface\nP3 or R10\nP4 or R11\nNosing or landing edge strip\nP3\nP4","g":"/ncc/d3d15","a19":["D2.14"]},{"c":"D3D16","t":"Thresholds","p":"Part D3 Construction of exits","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d3-construction-exits#D3D16","x":"The threshold of a doorway must not incorporate a step or ramp at any point closer to the doorway than the width of the door leaf unless the doorway opens to an external space; and—\nwhere the doorway serves an area required to be accessible by Part D4, it is provided with a threshold ramp or step ramp in accordance with AS 1428.1; or\nwhere (a) does not apply, the door sill is not located below, and is not more than 190 mm above, the finished surface of the ground, balcony, or the like to which the doorway opens.\nExemptions\nD3D16 does not apply to a plant room, machinery room, or the like.","g":"/ncc/d3d16","a19":["D2.15","NSW D2.15(d)","(e)","SA D2.15(e)"]},{"c":"D3D17","t":"Barriers to prevent falls","p":"Part D3 Construction of exits","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d3-construction-exits#D3D17","x":"(1) A continuous barrier must be provided along the side of—\na roof to which general access is provided; and\na stairway or ramp; and\na floor, corridor, hallway, balcony, deck, verandah, mezzanine, access bridge or the like; and\nany delineated path of access to a building,\nif the trafficable surface is 1 m or more above the surface beneath.\n(2) The requirements of (1) do not apply to—\nthe perimeter of a stage, rigging loft, loading dock or the like; or\nareas referred to in D3D23; or\na retaining wall, unless the retaining wall forms part of, or is directly associated with, a delineated path of access to a building from the road, or a delineated path of access between buildings; or\na barrier provided to an openable window covered by D3D29.\n(3) A barrier required by (1) must be constructed in accordance with D3D18, D3D19, D3D20 and, if a wire barrier is used, D3D21.","g":"/ncc/d3d17","a19":["D2.16(a)","(b) and (c)"]},{"c":"D3D18","t":"Height of barriers","p":"Part D3 Construction of exits","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d3-construction-exits#D3D18","x":"(1) The height of a barrier required by D3D17 must be not less than the following:\nFor stairways or ramps with a gradient of 1:20 or steeper — 865 mm.\nFor landings to a stair or ramp where the barrier is provided along the inside edge of the landing and does not exceed 500 mm in length — 865 mm.\nIn front of fixed seating on a mezzanine or balcony within an auditorium in a Class 9b building, where the horizontal projection extends not less than 1 m outwards from the top of the barrier — 700 mm.\nFor all other locations — 1 m.\n(2) For a barrier provided under (1) —\nbarrier heights are measured vertically from the surface beneath, except that for stairways the height must be measured above the nosing line of the stair treads; and\na transition zone may be incorporated where the barrier height changes from 865 mm on a stair flight or ramp to 1 m at a landing or floor.","g":"/ncc/d3d18","a19":["Table D2.16a"]},{"c":"D3D19","t":"Openings in barriers","p":"Part D3 Construction of exits","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d3-construction-exits#D3D19","x":"(1) Except where allowed by (2), openings in a required barrier must not allow a 125 mm sphere to pass through.\n(2) In a fire-isolated stairway, fire-isolated ramp or other area used primarily for emergency purposes, openings in a required barrier—\nmust not allow a 300 mm sphere to pass through; or\nwhere rails are used—\na 150 mm sphere must not be able to pass through the opening between the nosing line of the stair treads and the rail or between the rail and the floor of the landing, balcony or the like; and\nthe opening between rails must not be more than 460 mm.\n(3) In Class 7 (other than carparks) and Class 8 buildings, openings in a required barrier—\nmust not allow a 300 mm sphere to pass through; or\nwhere rails are used—\na 150 mm sphere must not be able to pass through the opening between the nosing line of the stair treads and the rail or between the rail and the floor of the landing, balcony or the like; and\nthe opening between the rails must not be more than 460 mm.\n(4) The requirements of (2) do not apply to external stairways, external ramps, or fire-isolated stairways or fire-isolated ramps serving Class 9b early childhood centres.\n(5) For a barrier provided under (1), the maximum 125 mm barrier opening for a stairway, such as a non fire-isolated stairway, is measured above the nosing line of the stair treads.\n(6) Where a required barrier is fixed to the vertical face forming an edge of a landing, balcony, deck, stairway or the like, the opening formed between the barrier and the face must not exceed 40 mm.\n(7) For the purposes of (6), the opening is measured horizontally from the edge of the trafficable surface to the nearest internal face of the barrier.","g":"/ncc/d3d19","a19":["Table D2.16a"]},{"c":"D3D20","t":"Barrier climbability","p":"Part D3 Construction of exits","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d3-construction-exits#D3D20","x":"(1) A barrier required by D3D17, located on a floor more than 4 m above the surface beneath, must not incorporate horizontal or near horizontal elements that could facilitate climbing between 150 mm and 760 mm above the floor.\n(2) The requirements of (1) do not apply to—\nfire-isolated stairways, fire-isolated ramps and other areas used primarily for emergency purposes, other than—\nexternal stairways; and\nexternal ramps; and\nClass 7 (other than carparks) and Class 8 buildings.","g":"/ncc/d3d20","a19":["Table D2.16a"]},{"c":"Table D3D21a","t":"Wire barrier construction – minimum required tension (N) for stainless steel horizontal wires","p":"Part D3 Construction of exits","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d3-construction-exits#_5b6e54fb-7132-4426-b1e1-a6ffa439140b","x":"Wire dia. (mm) | Lay | Wire spacing (mm) | Clear distance between posts (mm)\n600 | 800 | 900 | 1000 | 1200 | 1500 | 1800 | 2000 | 2500\n2.5 | 7x7 | 60 | 55 | 190 | 263 | 415 | 478 | 823 | 1080 | 1139 | X\n80 | 382 | 630 | 730 | 824 | 1025 | 1288 | X | X | X\n100 | 869 | 1218 | 1368 | X | X | X | X | X | X\n2.5 | 1x19 | 60 | 35 | 218 | 310 | 402 | 585 | 810 | 1125 | 1325 | X\n80 | 420 | 630 | 735 | 840 | 1050 | 1400 | 1750 | X | X\n100 | 1140 | 1565 | X | X | X | X | X | X | X\n3.0 | 7x7 | 60 | 15 | 178 | 270 | 314 | 506 | 660 | 965 | 1168 | 1491\n80 | 250 | 413 | 500 | 741 | 818 | 1083 | 1370 | 1565 | X\n100 | 865 | 1278 | 1390 | 1639 | X | X | X | X | X\n3.0 | 1x19 | 60 | 25 | 183 | 261 | 340 | 520 | 790 | 1025 | 1180 | X\n80 | 325 | 555 | 670 | 785 | 1015 | 1330 | 1725 | 1980 | X\n100 | 1090 | 1500 | 1705 | 1910 | X | X | X | X | X\n4.0 | 7x7 | 60 | 5 | 73 | 97 | 122 | 235 | 440 | 664 | 813 | 1178\n80 | 196 | 422 | 480 | 524 | 760 | 1100 | 1358 | 1530 | 2130\n100 | 835 | 1182 | 1360 | 1528 | 1837 | 2381 | 2811 | 3098 | X\n4.0 | 1x19 | 60 | 5 | 5 | 10 | 15 | 20 | 147 | 593 | 890 | 1280\n80 | 30 | 192 | 300 | 415 | 593 | 1105 | 1303 | 1435 | 1844\n100 | 853 | 1308 | 1487 | 1610 | 2048 | 2608 | 3094 | 3418 | 3849\n4.0 | 7x19 | 60 | 155 | 290 | 358 | 425 | 599 | 860 | 1080 | 1285 | 1540\n80 | 394 | 654 | 785 | 915 | 1143 | 1485 | 1860 | 2105 | 2615\n100 | 1038 | 1412 | 1598 | 1785 | 2165 | 2735 | X | X | X\nTable Notes\nLay = number of strands by the number of individual wires in each strand. For example a lay of 7x19 consists of 7 strands with 19 individual wires in each strand.\nWhere a change of direction is made in a run of wire, the tensioning device is to be placed at the end of the longest span.\nIf a 3.2 mm wire is used the tension figures for 3.0 mm wire are applied.\nThis table may also be used for a set of non-continuous (single) vertical wires forming a barrier using the appropriate clear distance between posts as the vertical clear distance between the rails.\nX = Not allowed because the required tension would exceed the safe load of the wire.\nTension measured with a strain indicator.","tb":"D3D21","g":"/ncc/table-d3d21a"},{"c":"Table D3D21b","t":"Continuous wire barrier construction – minimum required tension (N) for vertical or near-vertical stainless steel wires where the maximum clear spacing between the rails is 900 mm","p":"Part D3 Construction of exits","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d3-construction-exits#_721f0ae7-4ac7-406c-9183-35cd353d2d85","x":"Wire dia. (mm) | Lay | Widest spacing between wires (mm) | Required tension (N)\n2.5 | 7x19 | 80 | 145\n100 | 310\n110 | 610\n2.5 | 7x7 | 80 | 130\n100 | 280\n110 | 500\nTable Notes\nLay = number of strands by the number of individual wires in each strand. For example a lay of 7x19 consists of 7 strands with 19 individual wires in each strand.\nVertical wires require two pulley blocks to each 180° change of direction in the wire.\nNear vertical wires may only require one pulley block for each change of direction.\nTension measured with a strain indicator.\nThe table only includes 7x7 and 7x19 wires due to other wires not having sufficient flexibility to make the necessary turns.","tb":"D3D21","g":"/ncc/table-d3d21b"},{"c":"Table D3D21c","t":"Wire barrier construction – maximum permissible deflection of each wire in mm when a 2 kg mass is suspended at mid-span for stainless steel wires","p":"Part D3 Construction of exits","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d3-construction-exits#_01fc4725-1074-4d00-a934-904d73dc3981","x":"Wire dia. (mm) | Wire spacing (mm) | Clear distance between posts (mm)\n600 | 900 | 1200 | 1500 | 1800 | 2000\n2.5 | 60 | 17 | 11 | 9 | 8 | 8 | 8\n80 | 7 | 5 | 5 | 5 | X | X\n3.0 | 60 | 19 | 13 | 8 | 7 | 7 | 7\n80 | 8 | 6 | 6 | 5 | 5 | 5\n4.0 | 60 | 18 | 12 | 8 | 8 | 7 | 7\n80 | 8 | 6 | 4 | 4 | 4 | 4\nTable Notes\nWhere a change of direction is made in a run of wire the 2 kg mass must be placed at the middle of the longest span.\nIf a 3.2 mm wire is used the deflection figures for 3.0 mm wire are applied.\nThis table may also be used for a set of non-continuous (single) vertical wires forming a barrier using the appropriate clear distance between posts as the vertical clear distance between the rails. The deflection (offset) is measured by hooking a standard spring scale to the mid span of each wire and pulling it horizontally until a force of 19.6 N is applied.\nX = Not allowed because the required tension would exceed the safe load of the wire.\nThis table has been limited to 60 mm and 80 mm spaces for 2.5 mm, 3 mm and 4 mm diameter wires because the required wire tensions at greater spacings would require the tension to be beyond the wire safe load limit, or the allowed deflection would be impractical to measure.","tb":"D3D21","g":"/ncc/table-d3d21c"},{"c":"D3D21","t":"Wire barriers","p":"Part D3 Construction of exits","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d3-construction-exits#D3D21","x":"Where a required barrier is constructed of wire, it is deemed to meet the requirements of D3D19(1) if it is constructed in accordance with the following:\nFor horizontal wire systems—\nwhen measured with a strain indicator, it must be in accordance with the tension values in Table D3D21a; or\nmust not exceed the maximum deflections in Table D3D21c.\nFor non-continuous vertical wire systems, when measured with a strain indicator, must be in accordance with the tension values in Table D3D21a (see Note 4).\nFor continuous vertical or continuous near vertical sloped wire systems—\nmust have wires of no more than 2.5 mm diameter with a lay of 7×7 or 7×19 construction; and\nchanges in direction at support rails must pass around a pulley block without causing permanent deformation to the wire; and\nmust have supporting rails, constructed with a spacing of not more than 900 mm, of a material that does not allow deflection that would decrease the tension of the wire under load; and\nwhen the wire tension is measured with a strain indicator, it must be in accordance with the tension values in Table D3D21b and measured in the furthermost span from the tensioning device.\nTable D3D21a Wire barrier construction – minimum required tension (N) for stainless steel horizontal wires\nWire dia. (mm)\nLay\nWire spacing (mm)\nClear distance between posts (mm)\n600\n800\n900\n1000\n1200\n1500\n1800\n2000\n2500\n2.5\n7x7\n60\n55\n190\n263\n415\n478\n823\n1080\n1139\nX\n80\n382\n630\n730\n824\n1025\n1288\nX\nX\nX\n100\n869\n1218\n1368\nX\nX\nX\nX\nX\nX\n2.5\n1x19\n60\n35\n218\n310\n402\n585\n810\n1125\n1325\nX\n80\n420\n630\n735\n840\n1050\n1400\n1750\nX\nX\n100\n1140\n1565\nX\nX\nX\nX\nX\nX\nX\n3.0\n7x7\n60\n15\n178\n270\n314\n506\n660\n965\n1168\n1491\n80\n250\n413\n500\n741\n818\n1083\n1370\n1565\nX\n100\n865\n1278\n1390\n1639\nX\nX\nX\nX\nX\n3.0\n1x19\n60\n25\n183\n261\n340\n520\n790\n1025\n1180\nX\n80\n325\n555\n670\n785\n1015\n1330\n1725\n1980\nX\n100\n1090\n1500\n1705\n1910\nX\nX\nX\nX\nX\n4.0\n7x7\n60\n5\n73\n97\n122\n235\n440\n664\n813\n1178\n80\n196\n422\n480\n524\n760\n1100\n1358\n1530\n2130\n100\n835\n1182\n1360\n1528\n1837\n2381\n2811\n3098\nX\n4.0\n1x19\n60\n5\n5\n10\n15\n20\n147\n593\n890\n1280\n80\n30\n192\n300\n415\n593\n1105\n1303\n1435\n1844\n100\n853\n1308\n1487\n1610\n2048\n2608\n3094\n3418\n3849\n4.0\n7x19\n60\n155\n290\n358\n425\n599\n860\n1080\n1285\n1540\n80\n394\n654\n785\n915\n1143\n1485\n1860\n2105\n2615\n100\n1038\n1412\n1598\n1785\n2165\n2735\nX\nX\nX\nTable Notes\nLay = number of strands by the number of individual wires in each strand. For example a lay of 7x19 consists of 7 strands with 19 individual wires in each strand.\nWhere a change of direction is made in a run of wire, the tensioning device is to be placed at the end of the longest span.\nIf a 3.2 mm wire is used the tension figures for 3.0 mm wire are applied.\nThis table may also be used for a set of non-continuous (single) vertical wires forming a barrier using the appropriate clear distance between posts as the vertical clear distance between the rails.\nX = Not allowed because the required tension would exceed the safe load of the wire.\nTension measured with a strain indicator.\nTable D3D21b Continuous wire barrier construction – minimum required tension (N) for vertical or near-vertical stainless steel wires where the maximum clear spacing between the rails is 900 mm\nWire dia. (mm)\nLay\nWidest spacing between wires (mm)\nRequired tension (N)\n2.5\n7x19\n80\n145\n100\n310\n110\n610\n2.5\n7x7\n80\n130\n100\n280\n110\n500\nTable Notes\nLay = number of strands by the number of individual wires in each strand. For example a lay of 7x19 consists of 7 strands with 19 individual wires in each strand.\nVertical wires require two pulley blocks to each 180° change of direction in the wire.\nNear vertical wires may only require one pulley block for each change of direction.\nTension measured with a strain indicator.\nThe table only includes 7x7 and 7x19 wires due to other wires not having sufficient flexibility to make the necessary turns.\nTable D3D21c Wire barrier construction – maximum permissible deflection of each wire in mm when a 2 kg mass is suspended at mid-span for stainless steel wires\nWire dia. (mm)\nWire spacing (mm)\nClear distance between posts (mm)\n600\n900\n1200\n1500\n1800\n2000\n2.5\n60\n17\n11\n9\n8\n8\n8\n80\n7\n5\n5\n5\nX\nX\n3.0\n60\n19\n13\n8\n7\n7\n7\n80\n8\n6\n6\n5\n5\n5\n4.0\n60\n18\n12\n8\n8\n7\n7\n80\n8\n6\n4\n4\n4\n4\nTable Notes\nWhere a change of direction is made in a run of wire the 2 kg mass must be placed at the middle of the longest span.\nIf a 3.2 mm wire is used the deflection figures for 3.0 mm wire are applied.\nThis table may also be used for a set of non-continuous (single) vertical wires forming a barrier using the appropriate clear distance between posts as the vertical clear distance between the rails. The deflection (offset) is measured by hooking a standard spring scale to the mid span of each wire and pulling it horizontally until a force of 19.6 N is applied.\nX = Not allowed because the required tension would exceed the safe load of the wire.\nThis table has been limited to 60 mm and 80 mm spaces for 2.5 mm, 3 mm and 4 mm diameter wires because the required wire tensions at greater spacings would require the tension to be beyond the wire safe load limit, or the allowed deflection would be impractical to measure.","g":"/ncc/d3d21","a19":["D2.16(d)"]},{"c":"D3D22","t":"Handrails","p":"Part D3 Construction of exits","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d3-construction-exits#D3D22","x":"(1) Subject to (2), handrails must—\nbe located along at least one side of the ramp or flight; and\nbe located along each side if the total width of the stairway or ramp is 2 m or more; and\nin a Class 9b building used as a primary school or a building that contains an early childhood centre —\nhave one handrail fixed at a height of not less than 865 mm; and\nin addition to (i), have a handrail—\nfixed at a height between 665 mm and 750 mm in a primary school; and\nwith a cross-sectional dimension not less than 16 mm and not greater than 45 mm as measured in any direction across its centre, fixed at a height between 450 mm and 700 mm in a Class 9b early childhood centre; and\nin any other case, be fixed at a height of not less than 865 mm; and\nbe continuous between stair flight landings and have no obstruction on or above them that will tend to break a hand-hold; and\nin a required exit serving an area required to be accessible, be designed and constructed to comply with clause 9 of AS 1428.1, except that clause 9(d) does not apply to a handrail required by (1)(c)(ii).\n(2) For the purposes of (1) the following applies.\n(1) does not apply to—\nhandrails referred to in D3D23; and\nstep ramps, threshold ramps and kerb ramps.\nThe height required by (1)(c) and (d) is measured above the nosings of stair treads and the floor surface of the ramp, landing or the like.\n(3) Handrails—\nin a Class 9a health-care building must be provided along at least one side of every passageway or corridor used by patients, and must be—\nfixed not less than 50 mm clear of the wall; and\nwhere practicable, continuous for their full length; and\nin a Class 9c aged care building must be provided along both sides of every passageway or corridor used by residents, and must be—\nfixed not less than 50 mm clear of the wall; and\nwhere practicable, continuous for their full length.\n(4) Handrails required to assist people with a disability must be provided in accordance with D4D4.\n(5) Handrails to a stairway or ramp within a sole-occupancy unit in a Class 2 or 3 building or Class 4 part of a building must—\nbe located along at least one side of the flight or ramp; and\nbe located along the full length of the flight or ramp, except in the case where a handrail is associated with a barrier, the handrail may terminate where the barrier terminates; and\nhave the top surface of the handrail not less than 865 mm vertically above the nosings of the stair treads or the floor surface of the ramp; and\nhave no obstruction on or above them that will tend to break a handhold, except for newel posts, ball type stanchions, or the like.\n(6) The requirements of (5) do not apply to—\nhandrails referred to in D3D23; or\na stairway or ramp providing a change in elevation of less than 1 m; or\na landing; or\na winder where a newel post is installed to provide a handhold.","g":"/ncc/d3d22","a19":["D2.17"]},{"c":"D3D23","t":"Fixed platforms, walkways, stairways and ladders","p":"Part D3 Construction of exits","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d3-construction-exits#D3D23","x":"A fixed platform, walkway, stairway, ladder and any going and riser, landing, handrail or barrier attached thereto may comply with AS 1657 in lieu of D3D14, D3D15, D3D17, D3D18, D3D19, D3D20, D3D21 and D3D22 if it only serves—\nmachinery rooms, boiler houses, lift-machine rooms, plant-rooms, and the like; or\nnon-habitable rooms, such as attics, storerooms and the like that are not used on a frequent or daily basis in the internal parts of a sole-occupancy unit in a Class 2 building or Class 4 part of a building.","g":"/ncc/d3d23","a19":["SA D2.18(c)","D2.18"]},{"c":"D3D24","t":"Doorways and doors","p":"Part D3 Construction of exits","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d3-construction-exits#D3D24","x":"(1) A doorway in a resident use area of a Class 9c building must not be fitted with—\na sliding fire door; or\na sliding smoke door; or\na revolving door; or\na roller shutter door; or\na tilt-up door.\n(2) A doorway serving as a required exit or forming part of a required exit, or a doorway in a patient care area of a Class 9a health-care building —\nmust not be fitted with a revolving door; and\nmust not be fitted with a roller shutter or tilt-up door unless—\nit serves a Class 6, 7 or 8 building or part with a floor area not more than 200 m2; and\nthe doorway is the only required exit from the building or part; and\nit is held in the open position while the building or part is lawfully occupied; and\nmust not be fitted with a sliding door unless—\nit leads directly to a road or open space; and\nthe door is able to be opened manually under a force of not more than 110 N; and\nif fitted with a door which is power-operated—\nit must be able to be opened manually under a force of not more than 110 N if there is a malfunction or failure of the power source; and\nif it leads directly to a road or open space it must open automatically if there is a power failure to the door or on the activation of a fire or smoke alarm anywhere in the fire compartment served by the door.\n(3) A power-operated door in a path of travel to a required exit, except for a door in a patient care area of a Class 9a health-care building as provided in (2), must be able to be opened manually under a force of not more than 110 N if there is a malfunction or failure of the power source.","g":"/ncc/d3d24","a19":["D2.19"]},{"c":"D3D25","t":"Swinging doors","p":"Part D3 Construction of exits","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d3-construction-exits#D3D25","x":"(1) A swinging door in a required exit or forming part of a required exit —\nmust not encroach—\nat any part of its swing by more than 500 mm on the required width (including any landings) of a required stairway, ramp or passageway if it is likely to impede the path of travel of the people already using the exit; and\nwhen fully open, by more than 100 mm on the required width of the required exit; and\nmust swing in the direction of egress unless—\nit serves a building or part with a floor area not more than 200 m2, it is the only required exit from the building or part and it is fitted with a device for holding it in the open position; or\nit serves a sanitary compartment or airlock (in which case it may swing in either direction); and\nmust not otherwise impede the path or direction of egress.\n(2) The measurement of encroachment referred to in (1)(a) in each case is to include door handles or other furniture or attachments to the door.","g":"/ncc/d3d25","a19":["D2.20"]},{"c":"D3D26","t":"Operation of latch","p":"Part D3 Construction of exits","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d3-construction-exits#D3D26","x":"(1) A door in a required exit, forming part of a required exit or in the path of travel to a required exit must be readily openable without a key from the side that faces a person seeking egress, by—\na single hand downward action on a single device which is located between 900 mm and 1.1 m from the floor and if serving an area required to be accessible by Part D4 —\nbe such that the hand of a person who cannot grip will not slip from the handle during the operation of the latch; and\nhave a clearance between the handle and the back plate or door face at the centre grip section of the handle of not less than 35 mm and not more than 45 mm; or\na single hand pushing action on a single device which is located between 900 mm and 1.2 m from the floor.\n(2) Where the latch operation device referred to in (1)(b) is not located on the door leaf itself—\nmanual controls to power-operated doors must be at least 25 mm wide, proud of the surrounding surface and located—\nnot less than 500 mm from an internal corner; and\nfor a hinged door, between 1 m and 2 m from the door leaf in any position; and\nfor a sliding door, within 2 m of the doorway and clear of a surface mounted door in the open position; and\nbraille and tactile signage complying with S15C3 and S15C6 must identify the latch operation device.\n(3) The requirements of (1) and (2) do not apply to a door that—\nserves a vault, strong-room, sanitary compartment, or the like; or\nserves only, or is within—\na sole-occupancy unit in a Class 2 building or a Class 4 part of a building; or\na sole-occupancy unit in a Class 3 building (other than an entry door to a sole-occupancy unit of a boarding house, guest house, hostel, lodging house or backpacker accommodation); or\na sole-occupancy unit with a floor area not more than 200 m2 in a Class 5, 6, 7 or 8 building; or\na space which is otherwise inaccessible to persons at all times when the door is locked; or\ncomplies with (4) and serves—\nAustralian Government Security Zones 4 or 5; or\nthe secure parts of a bank, detention centre, mental health facility, early childhood centre or the like; or\nis fitted with a fail-safe device which automatically unlocks the door upon the activation of any sprinkler system (other than a FPAA101D system) complying with Specification 17 or smoke, or any other detector system deemed suitable in accordance with AS 1670.1 installed throughout the building, and is readily openable when unlocked; or\nis in a Class 9a or 9c building and—\nis one leaf of a two-leaf door complying with D2D9(a) or D2D9(d) provided that it is not held closed by a locking mechanism and is readily openable; and\nthe door is not required to be a fire door or smoke door.\n(4) A door referred to in (3)(c) must be able to be immediately unlocked—\nby operating a fail-safe control switch, not contained within a protective enclosure, to actuate a device to unlock the door; or\nby hand by a person or persons, specifically nominated by the owner, properly instructed as to the duties and responsibilities involved and available at all times when the building is lawfully occupied so that persons in the building or part may immediately escape if there is a fire.\n(5) The requirements of (1) and (2) do not apply in a Class 9b building (other than a school, an early childhood centre or a building used for religious purposes) to a door in a required exit, forming part of a required exit or in the path of travel to a required exit serving a storey or room accommodating more than 100 persons, determined in accordance with D2D18, in which case it must be readily openable—\nwithout a key from the side that faces a person seeking egress; and\nby a single hand pushing action on a single device such as a panic bar located between 900 mm and 1.2 m from the floor; and\nwhere a two-leaf door is fitted, the provisions of (a) and (b) need only apply to one door leaf if the appropriate requirements of D2D9 are satisfied by the opening of that one leaf.","g":"/ncc/d3d26","a19":["D2.21"]},{"c":"D3D27","t":"Re-entry from fire-isolated exits","p":"Part D3 Construction of exits","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d3-construction-exits#D3D27","x":"(1) Doors of a fire-isolated exit must not be locked from the inside as follows:\nIn a Class 2 building.\nIn a Class 3 building.\nIn a Class 6 building.\nIn a Class 7a building.\nIn a Class 9 building.\nIn a fire-isolated exit serving any storey above an effective height of 25 m, throughout the exit.\n(2) The requirements of (1) do not apply to a door, other than a door in a Class 9b early childhood centre, fitted with a fail-safe device that automatically unlocks the door upon the activation of a fire alarm and—\nre-entry is facilitated by—\non at least every fourth storey, the doors are not able to be locked and a sign is fixed on such doors stating that re-entry is available; and\non at least every second storey where re-entry is not available, a sign is fixed to the wall within the fire-isolated exit within 1.5 m of the exit door stating the location of nearby re-entry; or\nan intercommunication system, or an audible or visual alarm system, operated from within the enclosure is provided near the doors on at least every fourth storey, and a sign is fixed adjacent to such doors explaining its purpose and method of operation, and on at least every second storey where re-entry is not available, a sign is fixed to the wall within the fire-isolated exit within 1.5 m of the exit door stating the location of a nearby intercommunication system.\n(3) The requirements of (1)(e) do not apply to a door in a Class 9b early childhood centre fitted with a fail-safe device that automatically unlocks the door upon the activation of a fire alarm.","g":"/ncc/d3d27","a19":["D2.22"]},{"c":"D3D28","t":"Signs on doors","p":"Part D3 Construction of exits","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d3-construction-exits#D3D28","x":"(1) A sign, to alert persons that the operation of certain doors must not be impaired, must be installed where it can readily be seen on, or adjacent to—\na required —\nfire door providing direct access to a fire-isolated exit, except a door providing direct egress from a sole-occupancy unit in a Class 2 or 3 building or Class 4 part of a building; and\nsmoke door; and\nany door which is a—\nfire door forming part of a horizontal exit; and\nsmoke door that swings in both directions; and\ndoor leading from a fire isolated exit to a road or open space.\n(2) A sign required by (1)(a) must be fixed on the side of the door that faces a person seeking egress and, if the door is fitted with a device for holding it in the open position, either a sign must be fixed on the wall adjacent to the doorway, or signs must be fixed to both sides of the door.\n(3) A sign required by (1)(b) must be fixed on each side of the door.\n(4) A sign referred to in (1) must be in capital letters not less than 20 mm high in a colour contrasting with the background and state the following:\nFor an automatic door held open by an automatic hold-open device—\nFIRE SAFETY DOOR — DO NOT OBSTRUCT\nFor a self-closing door—\nFIRE SAFETY DOOR\nDO NOT OBSTRUCT\nDO NOT KEEP OPEN\nFor a door discharging from a fire-isolated exit —\nFIRE SAFETY DOOR — DO NOT OBSTRUCT","g":"/ncc/d3d28","a19":["D2.23"]},{"c":"D3D29","t":"Protection of openable windows","p":"Part D3 Construction of exits","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d3-construction-exits#D3D29","x":"(1) A window opening must be provided with protection, if the floor below the window is 2 m or more above the surface beneath in—\na bedroom in a Class 2 or 3 building or Class 4 part of a building; or\na Class 9b early childhood centre.\n(2) Where the lowest level of the window opening is less than 1.7 m above the floor, a window opening covered by (1) must comply with the following:\nThe openable portion of the window must be protected with—\na device capable of restricting the window opening; or\na screen with secure fittings.\nA device or screen required by (a) must—\nnot permit a 125 mm sphere to pass through the window opening or screen; and\nresist an outward horizontal action of 250 N against the—\nwindow restrained by a device; or\nscreen protecting the opening; and\nhave a child resistant release mechanism if the screen or device is able to be removed, unlocked or overridden.\n(3) A barrier with a height not less than 865 mm above the floor is required to an openable window—\nin addition to window protection, when a child resistant release mechanism is required by (2)(b)(iii); and\nwhere the floor below the window is 4 m or more above the surface beneath if the window is not covered by (1).\n(4) A barrier covered by (3) except for (5) must not—\npermit a 125 mm sphere to pass through it; and\nhave any horizontal or near horizontal elements between 150 mm and 760 mm above the floor that facilitate climbing.\n(5) A barrier required by (3) to an openable window in—\nfire-isolated stairways, fire-isolated ramps and other areas used primarily for emergency purposes, excluding external stairways and external ramps; and\nClass 7 (other than carparks) and Class 8 buildings and parts of buildings containing those classes,\nmust not permit a 300 mm sphere to pass through it.","g":"/ncc/d3d29","a19":["D2.24"]},{"c":"D3D30","t":"Timber stairways: Concession","p":"Part D3 Construction of exits","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d3-construction-exits#D3D30","x":"(1) Notwithstanding D3D3(a), timber treads, risers, landings and associated supporting framework within a required fire-isolated stairway or fire-isolated passageway may be constructed from fire-protected timber in accordance with C2D13 —\nif the timber—\nhas a finished thickness of not less than 44 mm; and\nhas an average density of not less than 800 kg/m3 at a moisture content of 12%; and\nsubject to—\nthe building being protected throughout by a sprinkler system (other than a FPAA101D system) complying with Specification 17 which extends to within the fire-isolated enclosure; and\nfire protection being provided to the underside of stair flights and landings located immediately above a landing level which—\nis at or near the level of egress; or\nprovides direct access to a carpark.\n(2) Fire protection required by (1) must be not less than one layer of 13 mm fire-protective grade plasterboard fixed in accordance with the system requirements for a fire-protective covering.","g":"/ncc/d3d30","a19":["D2.25"]},{"c":"D3D31","t":"Wayfinding signage","p":"Part D3 Construction of exits","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d3-construction-exits#D3D31","x":"(1) Buildings with an effective height of more than 12 m or with more than 3 below ground storeys must be provided with stairway identification signs, floor level identification signs and sole-occupancy unit indicator signs in accordance with (2) to (6).\n(2) Stairway identification signs must—\nbe located external to the exit on or adjacent to all doors that provide access into required fire-isolated stairways, including discharge doors; and\nidentify the floor levels served where the required fire-isolated stairway does not serve all floor levels; and\nstate—\n“Stair”, or in the case of a scissor stair “Scissor Stair”, and\na unique stair descriptor; and\nuse text that—\nis not less than 50 mm high; and\ncontrasts with its background; and\nis legible in low level lighting conditions or when illuminated with a torch.\n(3) Floor level identification signs must—\nbe located—\nat every landing that is located at a floor level and is in a required fire-isolated stairway; and\nat every corridor or lobby into which an emergency lift or lift with a stretcher facility opens; and\nbe visible from the top step of the flight serving the relevant floor and, where possible, from inside the relevant lift where the lift car door open; and\nbe mounted between 1.7 m and 2 m above floor level and, as far as practicable, at the same height; and\nwhere within a required fire-isolated stairway, identify that required exit stairway in accordance with (2)(c); and\nstate—\n“Ground Floor” when identifying the ground floor level; or\n“Level”, or in the case of a basement level “Basement”, in conjunction with a floor level descriptor; and\nuse text that—\nis not less than 50 mm high, except the height of the character that designates the floor level descriptor must be at least 100 mm high; and\ncontrasts with the background, and\nis legible in low level lighting conditions or when illuminated with a torch.\n(4) The floor level descriptor required by (3)(e)(ii) must—\nfor floor levels above the ground floor, be numbered sequentially beginning with”1”, and\nfor basement levels below the ground floor, be numbered sequentially beginning with “1”.\n(5) Where a storey in a Class 2 or Class 3 building contains more than one sole-occupancy unit, sole-occupancy unit indicator signs must be provided that state the direction to sole-occupancy units accessed on that storey.\n(6) Sole-occupancy unit identification signs required by (5) must—\nbe located immediately below floor identification signs provided under (3)(a), such that the top edge of the sign is not more than 50 mm below the bottom edge of the floor identification sign; and\nstate—\n“Units” or another suitable descriptor such as “Rooms” or “Apartments”; and\na sequential descriptor of the range of sole-occupancy units in each direction relative to the location of the sign; and\nthe direction in which the range of sole-occupancy units are relative to the location of the sign, such as by an arrow symbol; and\nuse text and symbols that—\nare not less than 25 mm high; and\ncontrast with the background; and\nare legible in low level lighting conditions or when illuminated with a torch.\nNotes\nWhere a sole-occupancy unit is accessed from 2 or more storeys, the sole-occupancy unit need only be identified by a sole-occupancy unit identification sign on the primary access storey.\nStairway, floor level and sole-occupancy unit designations are to be consistent with designations used in block plans and other fire safety system documentation.\nNotwithstanding D3D31(3)(e) and D3D31(4)—\nabbreviations (such as ‘G’ for ‘Ground Floor’) may be used; and\nthe ground level may be identified as ‘Level 1’; and\nmezzanines, split levels (such as lower ground and upper ground) and the like may be identified accordingly.","g":"/ncc/d3d31"},{"c":"D4D1","t":"Deemed-to-Satisfy Provisions","p":"Part D4 Access for people with a disability","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d4-access-people-disability#D4D1","x":"(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements D1P1 to D1P6, D1P8 and D1P10 are satisfied by complying with—\nD2D2 to D2D23, D3D2 to D3D31 and D4D2 to D4D13; and\nin a building containing an atrium, Part G3; and\nin a building in an alpine area, Part G4; and\nfor additional requirements for Class 9b buildings, Part I1; and\nfor public transport buildings, Part I2.\n(2) Where a Performance Solution is proposed, the relevant Performance Requirements must be determined in accordance with A2G2(3) and A2G4(3) as applicable.\n(3) Performance Requirement D1P7 must be complied with if lifts are to be used to assist occupants to evacuate a building.","g":"/ncc/d4d1","a19":["D3.0"]},{"c":"Table D4D2a","t":"Requirements for access for people with a disability – sole-occupancy units in a Class 1b building","p":"Part D4 Access for people with a disability","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d4-access-people-disability#_e1aaf424-bb3a-490a-b431-8aace1ebca04","x":"Total number of dwellings | Number required to be accessible\n4 to 10 | 1\n11 to 40 | 2\n41 to 60 | 3\n61 to 80 | 4\n81 to 100 | 5\nMore than 100 | 5 dwellings plus 1 additional dwelling for each additional 30 dwellings or part thereof in excess of 100 dwellings.","tb":"D4D2","g":"/ncc/table-d4d2a"},{"c":"Table D4D2b","t":"Requirements for access for people with a disability – sole-occupancy units in a Class 3 or 9c building","p":"Part D4 Access for people with a disability","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d4-access-people-disability#_118a8046-d884-4cc9-baa8-75574a067127","x":"Total number of sole-occupancy units | Number required to be accessible\n1 to 10 | 1\n11 to 40 | 2\n41 to 60 | 3\n61 to 80 | 4\n81 to 100 | 5\n101 to 200 | 5 sole-occupancy units plus 1 additional sole-occupancy unit for each additional 25 units or part thereof in excess of 100.\n201 to 500 | 9 sole-occupancy units plus 1 additional sole-occupancy unit for each additional 30 units or part thereof in excess of 200.\nMore than 500 | 19 sole-occupancy units plus 1 additional sole-occupancy unit for each additional 50 units or part thereof in excess of 500.\nTable Notes\nIn a Class 3 building, not more than 2 required accessible sole-occupancy units may be located adjacent to each other.\nIn a Class 3 or 9c building where more than 2 accessible sole-occupancy units are required, they must be representative of the range of rooms available.","tb":"D4D2","g":"/ncc/table-d4d2b"},{"c":"D4D2","t":"General building access requirements","p":"Part D4 Access for people with a disability","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d4-access-people-disability#D4D2","x":"(1) Buildings and parts of buildings must be accessible as required by this clause, unless exempted by D4D5.\n(2) Access requirements for a Class 1b building are as follows:\nDwellings located on one allotment and used for short-term holiday accommodation — to and within a number of dwellings determined in accordance with Table D4D2a.\nA boarding house, bed and breakfast, guest house, hostel or the like, other than those described in (a) — to and within—\none bedroom and associated sanitary facilities; and\nnot less than one of each type of room or space for use in common by the residents or guests, including a cooking facility, sauna, gymnasium, swimming pool, laundry, games room, eating area, or the like; and\nrooms or spaces for use in common by all residents on a floor to which access by way of a ramp complying with AS 1428.1 or a passenger lift is provided.\n(3) For the purposes of (2)(a), a community or strata-type subdivision or development is considered to be on a single allotment.\n(4) For a Class 2 building, common areas are to be accessible as follows:\nFrom a pedestrian entrance required to be accessible to at least one floor containing sole-occupancy units and to the entrance doorway of each sole-occupancy unit located on that level.\nTo and within not less than one of each type of room or space for use in common by the residents, including a cooking facility, sauna, gymnasium, swimming pool, common laundry, games room, individual shop, eating area, or the like.\nWhere a ramp complying with AS 1428.1 or a passenger lift is installed—\nto the entrance doorway of each sole-occupancy unit; and\nto and within rooms or spaces for use in common by the residents.\nThe requirements of (c) only apply where the space referred to in (c)(i) or (ii) is located on the levels served by the lift or ramp.\n(5) For a Class 3 building, access requirements are as follows:\nCommon areas:\nFrom a pedestrian entrance required to be accessible to at least one floor containing sole-occupancy units and to the entrance doorway of each sole-occupancy unit located on that level.\nTo and within not less than one of each type of room or space for use in common by the residents, including a cooking facility, sauna, gymnasium, swimming pool, common laundry, games room, TV room, individual shop, dining room, public viewing area, ticket purchasing service, lunch room, lounge room, or the like.\nWhere a ramp complying with AS 1428.1 or a passenger lift is installed—\nto the entrance doorway of each sole-occupancy unit; and\nto and within rooms or spaces for use in common by the residents.\nThe requirements of (iii) only apply where the space referred to in (iii)(A) or (iii)(B) is located on the levels served by the lift or ramp.\nTo and within sole-occupancy units — in accordance with Table D4D2b.\n(6) For Class 5, 6, 7b, 8 and 9a buildings, access must be provided to and within all areas normally used by the occupants.\n(7) For a Class 7a building, access must be provided to and within any level containing accessible carparking spaces.\n(8) For a Class 9b building, access requirements are as follows:\nSchools and early childhood centres — to and within all areas normally used by the occupants.\nAn assembly building, not being a school or early childhood centre — to and within—\nwheelchair seating spaces provided in accordance with D4D10; and\nall other areas normally used by the occupants, except that access need not be provided to tiers or platforms of seating areas that do not contain wheelchair seating spaces.\n(9) For a Class 9c building, access requirements are as follows:\nCommon areas:\nFrom a pedestrian entrance required to be accessible to at least one floor containing sole-occupancy units and to the entrance doorway of each sole-occupancy unit located on that level.\nTo and within not less than one of each type of room or space for use in common by the residents, including a cooking facility, sauna, gymnasium, swimming pool, common laundry, games room, TV room, individual shop, dining room, public viewing area, ticket purchasing service, lunch room, lounge room, or the like.\nWhere a ramp complying with AS 1428.1 or a passenger lift is installed—\nto the entrance doorway of each sole-occupancy unit; and\nto and within rooms or spaces for use in common by the residents.\nThe requirements of (iii) only apply where the space referred to in (iii)(A) or (iii)(B) is located on the levels served by the lift or ramp.\nSole-occupancy units — to and within a number of sole-occupancy units determined in accordance with Table D4D2b.\n(10) For a Class 10 building, access requirements are as follows:\nFor a Class 10a non-habitable building located in an accessible area intended for use by the public and containing a sanitary facility, change room facility or shelter, to and within—\nan accessible sanitary facility; and\na change room facility; and\na public shelter or the like.\nFor Class 10b swimming pools, to and into swimming pools with a total perimeter greater than 40 m, associated with a Class 1b, 2, 3, 5, 6, 7, 8 or 9 building that is required to be accessible, but not swimming pools for the exclusive use of occupants of a Class 1b building or a sole-occupancy unit in a Class 2 or Class 3 building.\nTable D4D2a Requirements for access for people with a disability – sole-occupancy units in a Class 1b building\nTotal number of dwellings\nNumber required to be accessible\n4 to 10\n1\n11 to 40\n2\n41 to 60\n3\n61 to 80\n4\n81 to 100\n5\nMore than 100\n5 dwellings plus 1 additional dwelling for each additional 30 dwellings or part thereof in excess of 100 dwellings.\nTable D4D2b Requirements for access for people with a disability – sole-occupancy units in a Class 3 or 9c building\nTotal number of sole-occupancy units\nNumber required to be accessible\n1 to 10\n1\n11 to 40\n2\n41 to 60\n3\n61 to 80\n4\n81 to 100\n5\n101 to 200\n5 sole-occupancy units plus 1 additional sole-occupancy unit for each additional 25 units or part thereof in excess of 100.\n201 to 500\n9 sole-occupancy units plus 1 additional sole-occupancy unit for each additional 30 units or part thereof in excess of 200.\nMore than 500\n19 sole-occupancy units plus 1 additional sole-occupancy unit for each additional 50 units or part thereof in excess of 500.\nTable Notes\nIn a Class 3 building, not more than 2 required accessible sole-occupancy units may be located adjacent to each other.\nIn a Class 3 or 9c building where more than 2 accessible sole-occupancy units are required, they must be representative of the range of rooms available.","g":"/ncc/d4d2","a19":["D3.1","Table D3.1"]},{"c":"D4D3","t":"Access to buildings","p":"Part D4 Access for people with a disability","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d4-access-people-disability#D4D3","x":"(1) An accessway must be provided to a building required to be accessible —\nfrom the main points of a pedestrian entry at the allotment boundary; and\nfrom another accessible building connected by a pedestrian link; and\nfrom any required accessible carparking space on the allotment.\n(2) In a building required to be accessible, an accessway must be provided through the principal pedestrian entrance, and—\nthrough not less than 50% of all pedestrian entrances including the principal pedestrian entrance; and\nin a building with a total floor area more than 500 m2, a pedestrian entrance which is not accessible must not be located more than 50 m from an accessible pedestrian entrance,\nexcept for pedestrian entrances serving only areas exempted by D4D5.\n(3) Where a pedestrian entrance required to be accessible has multiple doorways—\nif the pedestrian entrance consists of not more than 3 doorways — not less than 1 of those doorways must be accessible; and\nif a pedestrian entrance consists of more than 3 doorways — not less than 50% of those doorways must be accessible.\n(4) For the purposes of (3)—\nan accessible pedestrian entrance with multiple doorways is considered to be one pedestrian entrance where—\nall doorways serve the same part or parts of the building; and\nthe distance between each doorway is not more than the width of the widest doorway at that pedestrian entrance (see Figure D4D3); and\na doorway is considered to be the clear, unobstructed opening created by the opening of one or more door leaves (see Figure D4D3).\n(5) Where a doorway on an accessway has multiple leaves (except an automatic opening door), one of those leaves must have a clear opening width of not less than 850 mm in accordance with AS 1428.1.\nFigure D4D3 Doorways and pedestrian entrances for access purposes","g":"/ncc/d4d3","a19":["D3.2"]},{"c":"D4D4","t":"Parts of buildings to be accessible","p":"Part D4 Access for people with a disability","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d4-access-people-disability#D4D4","x":"In a building required to be accessible —\nevery ramp and stairway, except for ramps and stairways in areas exempted by D4D5, must comply with—\nfor a ramp, except a fire-isolated ramp, clause 7 of AS 1428.1; and\nfor a stairway, except a fire-isolated stairway, clause 8 of AS 1428.1; and\nfor a fire-isolated stairway, clause 8.1(f) and (g) of AS 1428.1; and\nevery passenger lift must comply with E3D7 and E3D8; and\naccessways must have—\npassing spaces complying with AS 1428.1 at maximum 20 m intervals on those parts of an accessway where a direct line of sight is not available; and\nturning spaces complying with AS 1428.1—\nwithin 2 m of the end of accessways where it is not possible to continue travelling along the accessway; and\nat maximum 20 m intervals along the accessway; and\nan intersection of accessways satisfies the spatial requirements for a passing and turning space; and\na passing space may serve as a turning space; and\na ramp complying with AS 1428.1 or a passenger lift need not be provided to serve a storey or level other than the entrance storey in a Class 5, 6, 7b or 8 building—\ncontaining not more than 3 storeys; and\nwith a floor area for each storey, excluding the entrance storey, of not more than 200 m2.","g":"/ncc/d4d4","a19":["D3.3"]},{"c":"D4D5","t":"Exemptions","p":"Part D4 Access for people with a disability","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d4-access-people-disability#D4D5","x":"The following areas are not required to be accessible:\nAn area where access would be inappropriate because of the particular purpose for which the area is used.\nAn area that would pose a health or safety risk for people with a disability.\nAny path of travel providing access only to an area exempted by (a) or (b).","g":"/ncc/d4d5","a19":["SA D3.4(d)","TAS D3.4(d)","D3.4"]},{"c":"D4D6","t":"Accessible carparking","p":"Part D4 Access for people with a disability","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d4-access-people-disability#D4D6","x":"(1) Accessible carparking spaces—\nsubject to (b), must be provided in accordance with (2) in—\na Class 7a building required to be accessible; and\na carparking area on the same allotment as a building required to be accessible; and\nneed not be provided in a Class 7a building or a carparking area where a parking service is provided and direct access to any of the carparking spaces is not available to the public; and\nsubject to (d), must comply with AS/NZS 2890.6; and\nneed not be identified with signage where there is a total of not more than 5 carparking spaces, so as to restrict the use of the carparking space only for people with a disability.\n(2) For each class of building to which the carpark or carparking area is associated, the number of accessible carparking spaces required is as follows:\nClass 1b and 3 buildings:\nFor a boarding house, guest house, hostel, lodging house, backpackers’ accommodation or the residential part of a hotel or motel, the number of accessible carparking spaces required is to be calculated by multiplying the total number of carparking spaces by the percentage of —\naccessible sole-occupancy units to the total number of sole-occupancy units; or\naccessible bedrooms to the total number of bedrooms.\nFor the purposes of (i), the calculated number is taken to the next whole figure.\nFor a residential part of a school, accommodation for the aged, disabled or children, residential part of a health-care building which accommodates members of staff or the residential part of a detention centre — 1 accessible space for every 100 carparking spaces or part thereof.\nClass 5, 7, 8 or 9c buildings — 1 accessible space for every 100 carparking spaces or part thereof.\nClass 6 buildings—\nwith up to 1000 carparking spaces — 1 accessible space for every 50 carparking spaces or part thereof; and\nfor each additional 100 carparking spaces or part thereof in excess of 1000 carparking spaces — 1 accessible space.\nClass 9a buildings:\nFor a hospital (non-outpatient area) — 1 accessible space for every 100 carparking spaces or part thereof.\nFor a hospital (outpatient area)—\nwith up to 1000 carparking spaces — 1 accessible space for every 50 carparking spaces or part thereof; and\nfor each additional 100 carparking spaces or part thereof in excess of 1000 carparking spaces — 1 accessible space.\nFor a nursing home — 1 accessible space for every 100 carparking spaces or part thereof.\nFor a clinic or day surgery not forming part of a hospital — 1 accessible space for every 50 carparking spaces or part thereof.\nClass 9b buildings:\nFor a school — 1 accessible space for every 100 carparking spaces or part thereof.\nFor other assembly buildings —\nwith up to 1000 carparking spaces — 1 accessible space for every 50 carparking spaces or part thereof; and\nfor each additional 100 carparking spaces or part thereof in excess of 1000 carparking spaces — 1 accessible space.","g":"/ncc/d4d6","a19":["D3.5","Table D3.5"]},{"c":"D4D7","t":"Signage","p":"Part D4 Access for people with a disability","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d4-access-people-disability#D4D7","x":"(1) In a building required to be accessible —\nbraille and tactile signage complying with Specification 15 must—\nincorporate the international symbol of access or deafness, as appropriate, in accordance with AS 1428.1 and identify each—\nsanitary facility, except a sanitary facility associated with a bedroom in a Class 1b building or a sole-occupancy unit in a Class 3 or Class 9c building; and\nspace with a hearing augmentation system; and\nidentify each door required by E4D5 to be provided with an exit sign and state—\n“Exit”; and\n“Level”; and\nthe floor level number or floor level descriptor, or a combination of the two.\nsignage including the international symbol for deafness in accordance with AS 1428.1 must be provided within a room containing a hearing augmentation system identifying—\nthe type of hearing augmentation; and\nthe area covered within the room; and\nif receivers are being used and where the receivers can be obtained; and\nsignage in accordance with AS 1428.1 must be provided for accessible unisex sanitary facilities to identify if the facility is suitable for left or right handed use; and\nsignage to identify an ambulant accessible sanitary facility in accordance with AS 1428.1 must be located on the door of the facility; and\nwhere a pedestrian entrance is not accessible, directional signage incorporating the international symbol of access, in accordance with AS 1428.1, must be provided to direct a person to the location of the nearest accessible pedestrian entrance; and\nwhere a bank of sanitary facilities is not provided with an accessible unisex sanitary facility, directional signage incorporating the international symbol of access in accordance with AS 1428.1 must be placed at the location of the sanitary facilities that are not accessible, to direct a person to the location of the nearest accessible unisex sanitary facility.\n(2) In a building that is subject to F4D12 and is required to be accessible, directional signage complying with Specification 15 to direct a person to the location of the nearest accessible adult change facility within that building must be provided at the location of each—\nbank of sanitary facilities; and\naccessible unisex sanitary facility, other than one that incorporates an accessible adult change facility.","g":"/ncc/d4d7","a19":["D3.6"]},{"c":"D4D8","t":"Hearing augmentation","p":"Part D4 Access for people with a disability","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d4-access-people-disability#D4D8","x":"(1) A hearing augmentation system must be provided where an inbuilt amplification system, other than one used only for emergency warning, is installed—\nin a room in a Class 9b building; or\nin an auditorium, conference room, meeting room or room for judicatory purposes; or\nat any ticket office, teller’s booth, reception area or the like, where the public is screened from the service provider.\n(2) If a hearing augmentation system required by (1) is—\nan induction loop, it must be provided to not less than 80% of the floor area of the room or space served by the inbuilt amplification system; or\na system requiring the use of receivers or the like, it must be available to not less than 95% of the floor area of the room or space served by the inbuilt amplification system, and the number of receivers provided must not be less than—\nif the room or space accommodates up to 500 persons, 1 receiver for every 25 persons or part thereof, or 2 receivers, whichever is the greater; and\nif the room or space accommodates more than 500 persons but not more than 1000 persons, 20 receivers plus 1 receiver for every 33 persons or part thereof in excess of 500 persons; and\nif the room or space accommodates more than 1000 persons but not more than 2000 persons, 35 receivers plus 1 receiver for every 50 persons or part thereof in excess of 1000 persons; and\nif the room or space accommodates more than 2000 persons, 55 receivers plus 1 receiver for every 100 persons or part thereof in excess of 2000 persons.\n(3) The number of persons accommodated in the room or space served by an inbuilt amplification system must be calculated according to D2D18.\n(4) Any screen or scoreboard associated with a Class 9b building and capable of displaying public announcements must be capable of supplementing any public address system, other than a public address system used for emergency warning purposes only.","g":"/ncc/d4d8","a19":["D3.7"]},{"c":"D4D9","t":"Tactile indicators","p":"Part D4 Access for people with a disability","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d4-access-people-disability#D4D9","x":"(1) For a building required to be accessible, tactile ground surface indicators must be provided to warn people who are blind or have a vision impairment that they are approaching—\na stairway, other than a fire-isolated stairway; and\nan escalator; and\na passenger conveyor or moving walk; and\na ramp other than a fire-isolated ramp, step ramp, kerb ramp or swimming pool ramp; and\nin the absence of a suitable barrier—\nan overhead obstruction less than 2 m above floor level, other than a doorway; and\nan accessway meeting a vehicular way adjacent to any pedestrian entrance to a building, excluding a pedestrian entrance serving an area referred to in D4D5, if there is no kerb or kerb ramp at that point,\nexcept for areas exempted by D4D5.\n(2) Tactile ground surface indicators required by (1) must comply with sections 1 and 2 of AS/NZS 1428.4.1.\n(3) A hostel for the aged, nursing home for the aged, a residential aged care building, Class 3 accommodation for the aged, Class 9a health-care building or a Class 9c aged care building need not comply with (1)(a) and (d) if handrails incorporating a raised dome button in accordance with AS/NZS 1428.4.1 are provided to warn people who are blind or have a vision impairment that they are approaching a stairway or ramp.","g":"/ncc/d4d9","a19":["D3.8"]},{"c":"Table D4D10","t":"Wheelchair seating spaces in Class 9b assembly buildings","p":"Part D4 Access for people with a disability","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d4-access-people-disability#_3a77606a-c0d4-4f61-83e1-b600e7158414","x":"Fixed seats in a room or space | Wheelchair spaces Note 1 | Grouping and location | Spaces must represent range of seating provided Note 3\nMinimum spaces required | 1 additional space required per Note 2 | Min. single spaces | Min. groups of 2 spaces | Max. spaces in any other group\nUp to 150 | 3 | N/A | 1 | 1 | N/A | No\n151 to 800 | 3 | 50 seats in excess of 150 seats | 1 | 1 | 5 | No\n801 to 10 000 | 16 | 100 seats in excess of 800 seats | 2 | 2 | 5 | Yes\nMore than 10 000 | 108 | 200 seats in excess of 10 000 seats | 5 | 5 | 10 | Yes\nTable Notes\nThe total number of required wheelchair spaces is the sum of the minimum spaces required (left column) and the additional spaces required (right column).\nThe first number referred to includes any part of that number (e.g. 1 additional space required per 50 seats or part thereof).\nThis means that the location of required wheelchair spaces must be representative of the range of seating provided.","tb":"D4D10","g":"/ncc/table-d4d10"},{"c":"D4D10","t":"Wheelchair seating spaces in Class 9b assembly buildings","p":"Part D4 Access for people with a disability","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d4-access-people-disability#D4D10","x":"Where fixed seating is provided in a Class 9b assembly building, wheelchair seating spaces complying with AS 1428.1 must be provided in accordance with the following:\nThe number and grouping of wheelchair seating spaces must be in accordance with Table D4D10.\nIn a cinema—\nwith not more than 300 seats — wheelchair seating spaces must not be located in the front row of seats; and\nwith more than 300 seats — not less than 75% of required wheelchair seating spaces must be located in rows other than the front row of seats.\nTable D4D10 Wheelchair seating spaces in Class 9b assembly buildings\nFixed seats in a room or space\nWheelchair spaces Note 1\nGrouping and location\nSpaces must represent range of seating provided Note 3\nMinimum spaces required\n1 additional space required per Note 2\nMin. single spaces\nMin. groups of 2 spaces\nMax. spaces in any other group\nUp to 150\n3\nN/A\n1\n1\nN/A\nNo\n151 to 800\n3\n50 seats in excess of 150 seats\n1\n1\n5\nNo\n801 to 10 000\n16\n100 seats in excess of 800 seats\n2\n2\n5\nYes\nMore than 10 000\n108\n200 seats in excess of 10 000 seats\n5\n5\n10\nYes\nTable Notes\nThe total number of required wheelchair spaces is the sum of the minimum spaces required (left column) and the additional spaces required (right column).\nThe first number referred to includes any part of that number (e.g. 1 additional space required per 50 seats or part thereof).\nThis means that the location of required wheelchair spaces must be representative of the range of seating provided.","g":"/ncc/d4d10","a19":["D3.9"]},{"c":"D4D11","t":"Swimming pools","p":"Part D4 Access for people with a disability","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d4-access-people-disability#D4D11","x":"(1) Not less than 1 means of accessible water entry/exit in accordance with Specification 16 must be provided for each swimming pool required by D4D2 to be accessible.\n(2) An accessible entry/exit must be by means of—\na fixed or movable ramp and an aquatic wheelchair; or\na zero depth entry and an aquatic wheelchair; or\na platform swimming pool lift and an aquatic wheelchair; or\na sling-style swimming pool lift.\n(3) Where a swimming pool has a perimeter of more than 70 m, at least one accessible water entry/exit must be provided by a means specified in (2)(a), (b) or (c).\n(4) Latching devices on gates and doors forming part of a swimming pool safety barrier need not comply with AS 1428.1.","g":"/ncc/d4d11","a19":["D3.10"]},{"c":"D4D12","t":"Ramps","p":"Part D4 Access for people with a disability","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d4-access-people-disability#D4D12","x":"On an accessway —\na series of connected ramps must not have a combined vertical rise of more than 3.6 m; and\na landing for a step ramp must not overlap a landing for another step ramp or ramp.","g":"/ncc/d4d12","a19":["D3.11"]},{"c":"D4D13","t":"Glazing on an accessway","p":"Part D4 Access for people with a disability","u":"/editions/ncc-2025/adopted/volume-one/d-access-and-egress/part-d4-access-people-disability#D4D13","x":"On an accessway, where there is no chair rail, handrail or transom, all frameless or fully glazed doors, sidelights and any glazing capable of being mistaken for a doorway or opening, must be clearly marked in accordance with AS 1428.1.","g":"/ncc/d4d13","a19":["D3.12"]},{"c":"S17C1","t":"Scope","p":"Specification 17 Fire sprinkler systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/17-fire-sprinkler-systems#S17C1","x":"This Specification sets out requirements for the design and installation of fire sprinkler systems.","g":"/ncc/s17c1","a19":["Spec E1.5: 1"]},{"c":"S17C2","t":"Application of automatic fire sprinkler standards","p":"Specification 17 Fire sprinkler systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/17-fire-sprinkler-systems#S17C2","x":"Subject to this Specification, an automatic fire sprinkler system must comply with—\nfor all building classifications: AS 2118.1; or\nfor a Class 2 or 3 building with an effective height of not more than 25 m and a rise in storeys of 4 or more: Specification 18 and the relevant provisions of this Specification as applicable; or\nfor Class 5, 6, 7, 8, 9a (other than a residential care building) or 9b (other than a Class 9b early childhood centre) parts of a building with an effective height not more than 25 m, which also contains Class 2 or 3 parts: a sprinkler system in accordance with Specification 18 as for a Class 2 or 3 building and the relevant provisions of this Specification except—\na FPAA101D sprinkler system cannot be used where the Class 5, 6, 7, 8, 9a (other than a residential care building) or 9b parts—\ncontain more than 2 storeys; or\nare more than 25% of the total floor area of the building; or\nare located above the fourth storey; and\na FPAA101D or FPAA101H sprinkler system cannot be used where the Class 7a part accommodates more than 40 vehicles; or\nfor a combined sprinkler and fire hydrant system: AS 2118.6; or\nfor a Class 9a health-care building used as a residential care building: AS 2118.4 as applicable; or\nfor a Class 2, 3 or 9c building: AS 2118.4 as applicable.","g":"/ncc/s17c2","a19":["VIC Spec E1.5: 2","Spec E1.5: 2"]},{"c":"S17C3","t":"Separation of sprinklered and non-sprinklered areas","p":"Specification 17 Fire sprinkler systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/17-fire-sprinkler-systems#S17C3","x":"Where a part of a building is not protected with sprinklers, the sprinklered and non-sprinklered parts must be fire-separated with a wall or floor which must—\ncomply with any specific requirement of the Deemed-to-Satisfy Provisions of the BCA; or\nwhere there is no specific requirement, comply with the relevant part of AS 2118, FPAA101D or FPAA101H.","g":"/ncc/s17c3","a19":["Spec E1.5: 3"]},{"c":"S17C4","t":"Protection of openings","p":"Specification 17 Fire sprinkler systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/17-fire-sprinkler-systems#S17C4","x":"Any openings, including those for service penetrations, in construction separating sprinklered and non-sprinklered parts of a building, including the construction separating the areas nominated for omitted protection in AS 2118.1, must be protected in accordance with the Deemed-to-Satisfy Provisions of Part C4.","g":"/ncc/s17c4","a19":["Spec E1.5: 4"]},{"c":"S17C5","t":"Quick response sprinklers","p":"Specification 17 Fire sprinkler systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/17-fire-sprinkler-systems#S17C5","x":"Quick response sprinklers may be installed only if they are suitable for the type of application proposed and it is demonstrated that the sprinkler system is designed to accommodate their use.","g":"/ncc/s17c5","a19":["Spec E1.5: 5"]},{"c":"S17C6","t":"Sprinkler valve enclosures","p":"Specification 17 Fire sprinkler systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/17-fire-sprinkler-systems#S17C6","x":"(1) Sprinkler alarm valves must be located in a secure room or enclosure which has direct egress to a road or open space.\n(2) All sprinkler valve rooms and enclosures must be secured with a system suitable for use by the fire brigade.","g":"/ncc/s17c6","a19":["Spec E1.5: 6"]},{"c":"S17C7","t":"Water supply","p":"Specification 17 Fire sprinkler systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/17-fire-sprinkler-systems#S17C7","x":"(1) A required sprinkler system must be provided with at least one water supply.\n(2) A required sprinkler system in a building greater than 25 m in effective height must be provided with a dual water supply except that a secondary water supply storage capacity of 25,000 litres may be used if—\nthe storage tank is located at the topmost storey of the building; and\nthe building occupancy is classified as no more hazardous than Ordinary Hazard 2 (OH2) under AS 2118.1; and\nan operational fire brigade service is available to attend a building fire.","g":"/ncc/s17c7","a19":["Spec E1.5: 7"]},{"c":"S17C8","t":"Building occupant warning system","p":"Specification 17 Fire sprinkler systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/17-fire-sprinkler-systems#S17C8","x":"A required sprinkler system, except a FPAA101D sprinkler system, must be connected to and activate a building occupant warning system complying with S20C7.","g":"/ncc/s17c8","a19":["Spec E1.5: 8"]},{"c":"S17C9","t":"Connection to other systems","p":"Specification 17 Fire sprinkler systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/17-fire-sprinkler-systems#S17C9","x":"Where a smoke hazard management system is installed and is actuated by smoke detectors, the sprinkler system must, wherever practicable, be arranged to also activate the smoke hazard management system.","g":"/ncc/s17c9","a19":["Spec E1.5: 9"]},{"c":"S17C10","t":"Anti-tamper devices","p":"Specification 17 Fire sprinkler systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/17-fire-sprinkler-systems#S17C10","x":"(1) Where a sprinkler system is installed—\nover any stage area in a theatre, public hall or the like, visual and audible status indication of sprinkler valves must be provided at the location normally used by the stage manager; or\nin a space housing lift electrical and control equipment (including machine rooms, secondary floors and sheave rooms), any valves provided to control sprinklers in these spaces must be located adjacent to the space.\n(2) Any valves provided to control sprinklers required by (1) must be fitted with anti-tamper monitoring devices connected to a monitoring panel.","g":"/ncc/s17c10","a19":["Spec E1.5: 10"]},{"c":"S17C11","t":"Sprinkler systems in carparks","p":"Specification 17 Fire sprinkler systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/17-fire-sprinkler-systems#S17C11","x":"A sprinkler system protecting a carpark complying with S5C19(3) in a multi-classified building must—\nbe independent of the sprinkler system protecting any part of the building not used as a carpark; or\nif forming part of a sprinkler system protecting a part of the building not used as a carpark, be designed such that the section protecting the non-carpark part can be isolated without interrupting the water supply or otherwise affecting the effective operation of the section protecting the carpark.","g":"/ncc/s17c11","a19":["Spec E1.5: 11"]},{"c":"S17C12","t":"Residential care buildings","p":"Specification 17 Fire sprinkler systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/17-fire-sprinkler-systems#S17C12","x":"(1) In addition to the provisions of AS 2118.4, a sprinkler system in—\na Class 3 building used as a residential care building; or\na Class 9a health-care building used as a residential care building; or\na Class 9c building,\nmust comply with sub-clause (2).\n(2) Any sprinkler system referred to in (1) must—\nbe provided with a monitored main stop valve in accordance with AS 2118.1; and\nbe permanently connected with a direct data link or other approved monitoring system to a fire station or fire station dispatch centre.","g":"/ncc/s17c12","a19":["Spec E1.5: 12"]},{"c":"S17C13","t":"Sprinkler systems in lift installations","p":"Specification 17 Fire sprinkler systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/17-fire-sprinkler-systems#S17C13","x":"(1) Where sprinklers are installed in a space housing lift electrical and control equipment, including machine rooms, secondary floors and sheave rooms, sprinklers in these spaces must—\nhave heads protected from accidental damage by way of a guard that will not impair the performance of the head; and\nbe capable of being isolated and drained, either separately or collectively, without isolating any other sprinklers within the building.\n(2) Valves provided to control sprinklers referred to in (1) must be installed in accordance with S17C10(2).","g":"/ncc/s17c13","a19":["Spec E1.5: 13"]},{"c":"S17C14","t":"Early childhood centres","p":"Specification 17 Fire sprinkler systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/17-fire-sprinkler-systems#S17C14","x":"Quick response sprinklers must be provided to a Class 9b early childhood centre required to have an automatic fire sprinkler system.\nLimitations\nS17C14 does not apply to a Class 9b early childhood centre —\nwholly within a storey that provides direct egress to a road or open space; or\nwith a rise in storeys of not more than 2, where the Class 9b early childhood centre is the only use in that building.","g":"/ncc/s17c14"},{"c":"S18C1","t":"Scope","p":"Specification 18 Class 2 and 3 buildings not more than 25 m in effective height","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/18-class-2-and-3-buildings-not-more-25-m-effective-height#S18C1","x":"This Specification sets out requirements for the design and installation of fire sprinkler systems, and concessions for Class 2 and 3 buildings not more than 25 m in effective height with a rise in storeys of 4 or more.","g":"/ncc/s18c1","a19":["Spec E1.5a: 1"]},{"c":"S18C2","t":"Application","p":"Specification 18 Class 2 and 3 buildings not more than 25 m in effective height","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/18-class-2-and-3-buildings-not-more-25-m-effective-height#S18C2","x":"The Deemed-to-Satisfy Provisions of this Specification take precedence where there is a difference to the Deemed-to-Satisfy Provisions of Sections C, D and E.","g":"/ncc/s18c2","a19":["Spec E1.5a: 1"]},{"c":"S18C3","t":"System requirements","p":"Specification 18 Class 2 and 3 buildings not more than 25 m in effective height","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/18-class-2-and-3-buildings-not-more-25-m-effective-height#S18C3","x":"(1) A required automatic fire sprinkler system installed in a Class 2 or 3 building with an effective height of not more than 25 m and a rise in storeys of 4 or more must comply with—\nAS 2118.1; or\nAS 2118.4, as applicable; or\nFPAA101D, except for residential care buildings; or\nFPAA101H, except for residential care buildings.\n(2) A Class 2 or 3 building not more than 25 m in effective height with a rise in storeys of 4 or more provided with an automatic fire sprinkler system under (1)(a) or (1)(b) may be constructed in accordance with S18C4(1), as applicable, provided—\nthe automatic fire sprinkler system is permanently connected to a fire alarm monitoring system connected to a fire station or fire station dispatch centre in accordance with Specification 23 if—\nthe system has more than 100 sprinkler heads; or\nin the case of a residential care building, the building will accommodate more than 32 residents; and\nthe automatic fire sprinkler system is fitted with sprinklers complying with clauses 4.4, 4.5 and 5.5.2 of AS 2118.4 in bedrooms; and\nan automatic smoke detection and alarm system is installed in accordance with Specification 20 except that it need not be connected to a fire alarm monitoring system connected to a fire station or fire station dispatch centre, and in the case of a residential care building it must be installed in accordance with—\nS20C4; or\nboth—\nS20C3, provided S20C3(1)(b) is applied as if the building was not protected with a sprinkler system; and\nSpecification 23; and\nin a residential care building, the automatic smoke detection and alarm system and the automatic fire sprinkler system are connected to a local fire indicator panel provided in accordance with Specification 23; and\nfire orders are provided in a Class 3 building in accordance with G4D8 as for a building in an alpine area.","g":"/ncc/s18c3","a19":["Spec E1.5a: 2"]},{"c":"S18C4","t":"Permitted concessions","p":"Specification 18 Class 2 and 3 buildings not more than 25 m in effective height","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/18-class-2-and-3-buildings-not-more-25-m-effective-height#S18C4","x":"(1) The following concessions are permitted for Class 2 and 3 buildings provided with a required automatic fire sprinkler system in accordance with S18C3(1)(a) or (1)(b):\nThe FRL for self-closing fire doors, as required by C4D9 and C4D12, may be reduced to not less than –/30/30.\nThe FRL for—\nall non-load bearing internal walls and shafts constructed of fire-protected timber, as required by Specification 5 to have FRLs greater than –/60/60, may be reduced to –/60/60 and service penetrations through non-load bearing internal walls and shafts constructed of fire-protected timber, required by C4D15, may be reduced to not less than –/60/15; and\nall other non-load bearing internal walls, as required by Specification 5, may be reduced to –/45/45 and the FRL for service penetrations through non-load bearing internal walls and shafts, as required by C4D15, may be reduced to –/45/15.\nThe FRL for fire-isolated stairways enclosed with non-load bearing construction, as required by D2D4, may be reduced to –/45/45.\nExcept in a residential care building, the maximum distance of travel, as required by D2D5(1)(a)(i), may be increased from 6 m to 12 m.\nThe maximum distance of travel from a single exit serving the storey at the level of egress to a road or open space, as required by D2D5(1)(a)(ii), may be increased from 20 m to 30 m.\nThe maximum distance between alternative exits, as required by D2D6(c)(i), may be increased from 45 m to 60 m.\nInternal fire hydrants in accordance with E1D2 are not required where—\nthe building is served by external fire hydrants that provide compliant coverage installed in accordance with E1D2, except that in a residential care building the nozzle at the end of the length of hose need only reach the entry door of any sole-occupancy unit to be considered as covering the area within the sole-occupancy unit; or\na dry fire hydrant system that otherwise complies with AS 2419.1 is installed in the building and—\neach fire hydrant head is located in accordance with E1D2 and fitted with a blank end cap or plug; and\nthe pipework is installed in accordance with E1D2 (as for a required fire main) except that it need not be connected to a water supply; and\na hydrant booster inlet connection is provided in accordance with E1D2; and\nan external street or feed hydrant capable of providing the required system flow is located within 60 m of the hydrant booster connection.\nAn emergency warning and intercom system need not be provided in a residential care building in accordance with E4D9 if a warning system with an override public address facility is installed in accordance with Specification 23.\n(2) The following concessions are permitted for Class 2 and 3 buildings provided with a required automatic fire sprinkler system in accordance with S18C3(1)(c):\nWindow openings need not be protected in accordance with C4D12(8) provided the room served by the window is sprinkler protected.\nThe FRL for—\nservice penetrations through non-load bearing internal walls and shafts, as required by C4D15, may be reduced to –/60/15; and\nnon-load bearing fire-resisting lift and stair shafts, as required by Specification 5, may be reduced to –/60/60.\nThe maximum distance of travel, as required by D2D5(1)(a)(i), may be increased from 6 m to 12 m.\nThe maximum distance of travel from a single exit serving the storey at the level of egress to a road or open space, as required by D2D5(1)(a)(ii), may be increased from 20 m to 30 m.\nThe maximum distance between alternative exits, as required by D2D6(c)(i), may be increased from 45 m to 60 m.\nInternal fire hydrants in accordance with E1D2 are not required where—\nthe building is served by external fire hydrants that provide compliant coverage installed in accordance with E1D2; or\na dry fire hydrant system that otherwise complies with AS 2419.1 is installed in the building except—\nthe system pipework is not connected to the water supply; and\nan on-site fire pumpset is not required; and\nthe minimum fire hydrant outlet flow of 6 L/s may be achieved when boosted by a fire brigade pumping appliance; and\nthe minimum pipe sizes specified in AS 2419.1 do not apply.\nWhere a dry fire hydrant system is installed for the purposes of (f)—\neach fire hydrant head must be located in accordance with E1D2 and fitted with a blank end cap or plug; and\na hydrant booster inlet connection must be provided in accordance with E1D2; and\nan external street or feed hydrant capable of providing the required system flow must be located within 60 m of the hydrant booster connection.\n(3) The following concessions are permitted for Class 2 and 3 buildings provided with a required automatic fire sprinkler system in accordance with S18C3(1)(d):\nWindow openings need not be protected in accordance with C4D12(8) provided the room served by the window is sprinkler protected.\nThe FRL for—\nservice penetrations through non-load bearing internal walls and shafts, as required by C4D15, may be reduced to –/60/15; and\nnon-load bearing fire-resisting lift and stair shafts, as required by Specification 5, may be reduced to –/60/60.\nThe maximum distance of travel, as required by D2D5(1)(a)(i), may be increased from 6 m to 12 m.\nThe maximum distance of travel from a single exit serving the storey at the level of egress to a road or open space, as required by D2D5(1)(a)(ii), may be increased from 20 m to 30 m.\nThe maximum distance between alternative exits, as required by D2D6(c)(i), may be increased from 45 m to 60 m.","g":"/ncc/s18c4","a19":["Spec E1.5a: 3"]},{"c":"S19C1","t":"Scope","p":"Specification 19 Fire control centres","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/19-fire-control-centres#S19C1","x":"(1) This Specification describes the construction and content of required fire control centres and rooms.\n(2) A fire control room is a fire control centre in a dedicated room with additional specific requirements.","g":"/ncc/s19c1","a19":["Spec E1.8: 1"]},{"c":"S19C2","t":"Application","p":"Specification 19 Fire control centres","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/19-fire-control-centres#S19C2","x":"(1) S19C3 to S19C6 apply to fire control centres (including fire control rooms).\n(2) S19C7 to S19C13 apply additional requirements to fire control rooms.","g":"/ncc/s19c2","a19":["Spec E1.8: 1"]},{"c":"S19C3","t":"Purpose and content of fire control centre","p":"Specification 19 Fire control centres","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/19-fire-control-centres#S19C3","x":"A fire control centre must—\nprovide an area from which fire-fighting operations or other emergency procedures can be directed or controlled; and\ncontain controls, panels, telephones, furniture, equipment and the like associated with the required fire services in the building; and\nnot be used for any purpose other than the control of—\nfire-fighting activities; and\nother measures concerning the occupant safety or security.","g":"/ncc/s19c3","a19":["Spec E1.8: 2"]},{"c":"S19C4","t":"Location of fire control centre","p":"Specification 19 Fire control centres","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/19-fire-control-centres#S19C4","x":"A fire control centre must be so located in a building that egress from any part of its floor, to a road or open space, does not involve changes in level which in aggregate exceed 300 mm.","g":"/ncc/s19c4","a19":["Spec E1.8: 3"]},{"c":"S19C5","t":"Equipment not permitted within a fire control centre","p":"Specification 19 Fire control centres","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/19-fire-control-centres#S19C5","x":"An internal combustion engine, pumps, sprinkler control valves, pipes and pipe fittings must not be located in a fire control centre, but may be located in rooms accessed through the fire control centre.","g":"/ncc/s19c5","a19":["Spec E1.8: 4"]},{"c":"S19C6","t":"Ambient sound level for a fire control centre","p":"Specification 19 Fire control centres","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/19-fire-control-centres#S19C6","x":"(1) The ambient sound level within the fire control centre measured when all fire safety equipment is operating in the manner in which it operates in an emergency must not exceed 65 dB(A).\n(2) The measurement must be taken for a sufficient time to characterise the effects of all sound sources.\n(3) Where there is not a great variation in noise level, a measurement time of 60 seconds may be used.","g":"/ncc/s19c6","a19":["Spec E1.8: 5"]},{"c":"S19C7","t":"Construction of a fire control room","p":"Specification 19 Fire control centres","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/19-fire-control-centres#S19C7","x":"A fire control centre in a building more than 50 m in effective height must be in a separate room where—\nthe enclosing construction is of concrete, masonry or the like, sufficiently impact resistant to withstand the impact of any likely falling debris, and with an FRL of not less than 120/120/120; and\nany material used as a finish, surface, lining or the like within the room complies with the requirements of Specification 7; and\nservices, pipes, ducts and the like that are not directly required for the proper functioning of the fire control room do not pass through it; and\nopenings in the walls, floors or ceiling which separate the room from the interior of the building are confined to doorways, ventilation and other openings for services necessary for the proper functioning of the facility.","g":"/ncc/s19c7","a19":["Spec E1.8: 6"]},{"c":"S19C8","t":"Protection of openings in a fire control room","p":"Specification 19 Fire control centres","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/19-fire-control-centres#S19C8","x":"Openings permitted by S19C7 must be protected as follows:\nOpenings for windows, doorways, ventilation, service pipes, conduits and the like, in an external wall of the building that faces a road or open space, must be protected in accordance with the Deemed-to-Satisfy Provisions of Part C4.\nOpenings in the floors, ceilings and internal walls enclosing a fire control room must, except for doorways, be protected in accordance with the Deemed-to-Satisfy Provisions of Part C4.\nA door opening in the internal walls enclosing a fire-control room, must be fitted with a self-closing –/120/30 smoke sealed fire door.\nOpenings associated with natural or mechanical ventilation must—\nnot be made in any ceiling or floor immediately above or below the fire control room; and\nbe protected by a –/120/– fire damper if the opening is for a duct through a wall required to have an FRL, other than an external wall.","g":"/ncc/s19c8","a19":["Spec E1.8: 7"]},{"c":"S19C9","t":"Doors to a fire control room","p":"Specification 19 Fire control centres","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/19-fire-control-centres#S19C9","x":"(1) Required doors to a fire control room must open into the room, be lockable and located so that persons using escape routes from the building will not obstruct or hinder access to the room.\n(2) The fire control room must be accessible via two paths of travel—\none from the front entrance of the building; and\none direct from a public place or fire-isolated passageway which leads to a public place and has a door with an FRL of not less than –/120/30.","g":"/ncc/s19c9","a19":["Spec E1.8: 8"]},{"c":"S19C10","t":"Size and contents of a fire control room","p":"Specification 19 Fire control centres","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/19-fire-control-centres#S19C10","x":"(1) A fire control room must contain—\na Fire Indicator Panel and necessary control switches and visual status indication for all required fire pumps, smoke control fans and other required fire safety equipment installed in the building; and\na telephone connected to the telecommunications network; and\na blackboard or whiteboard not less than 1200 mm wide x 1000 mm high; and\na pin-up board not less than 1200 mm wide x 1000 mm high; and\na raked plan layout table of a size suitable for laying out the plans provided under (f); and\ncolour-coded, durable, tactical fire plans.\n(2) In addition, a fire control room may contain—\nmaster emergency control panels, lift annunciator panels, remote switching controls for gas or electrical supplies and emergency generator backup; and\nbuilding security, surveillance and management systems if they are completely segregated from all other systems.\n(3) A fire control room must—\nhave a floor area of not less than 10 m2 and the length of any internal side must be not less than 2.5 m; and\nif only the minimum prescribed equipment is installed — have a net floor area of not less than 8 m2 with a clear space of not less than 1.5 m2 in front of the Fire Indicator Panel; and\nif additional equipment is installed — have an additional area of not less than 2 m2 net floor area for each additional facility and a clear space of not less than 1.5 m2 in front of each additional control or indicator panel; and\nbe constructed such that the area required for any path of travel through the room to other areas is provided in addition to the requirements (b) and (c).","g":"/ncc/s19c10","a19":["Spec E1.8: 9"]},{"c":"S19C11","t":"Ventilation and power supply for a fire control room","p":"Specification 19 Fire control centres","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/19-fire-control-centres#S19C11","x":"(1) A fire control room must be ventilated by—\nnatural ventilation from a window or doorway in an external wall of the building which opens directly into the fire control room from a road or open space; or\na pressurisation system that only serves the fire control room, and—\nis installed in accordance with AS 1668.1, except airflow rates nominated by clause 10.3 are replaced with not less than 30 air changes per hour, as though the room is a fire-isolated stairway; and\nis activated automatically by operation of the fire alarm, or sprinkler system complying with Specification 17, installed in the building and manually by an over-riding control in the room; and\nhas fans, motors and ductwork that form part of the system but not contained within the fire control room protected by enclosing construction with an FRL of not less than 120/120/120; and\nhas any electrical supply to the fire control room or equipment necessary for its operation connected to the supply side of the main disconnection switch for the building.\n(2) No openable devices, other than necessary doorways, pressure controlled relief louvres and windows that are openable by a key, must be constructed in the fire control room.","g":"/ncc/s19c11","a19":["Spec E1.8: 10"]},{"c":"S19C12","t":"Sign for a fire control room","p":"Specification 19 Fire control centres","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/19-fire-control-centres#S19C12","x":"The external face of the door to the fire control room must have a sign with the words—\nFIRE CONTROL ROOM\nin letters not less than 50 mm high and of a colour which contrasts with that of the background.","g":"/ncc/s19c12","a19":["Spec E1.8: 11"]},{"c":"S19C13","t":"Lighting for a fire control room","p":"Specification 19 Fire control centres","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/19-fire-control-centres#S19C13","x":"Emergency lighting in accordance with the Deemed-to-Satisfy Provisions of Part E4 must be provided in a fire control room, except that an illumination level of not less than 400 lux must be maintained at the surface of the plan table.","g":"/ncc/s19c13","a19":["Spec E1.8: 12"]},{"c":"S20C1","t":"Scope","p":"Specification 20 Smoke detection and alarm systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/20-smoke-detection-and-alarm-systems#S20C1","x":"This Specification describes the installation and operation of automatic smoke detection and alarm systems.","g":"/ncc/s20c1","a19":["Spec E2.2a: 1"]},{"c":"S20C2","t":"Type of system","p":"Specification 20 Smoke detection and alarm systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/20-smoke-detection-and-alarm-systems#S20C2","x":"A required automatic smoke detection and alarm system must be provided in accordance with the following:\nClass 2 buildings and Class 4 parts of a building—\na smoke alarm system complying with S20C3; or\na smoke detection system complying with S20C4; or\na combination of a smoke alarm system and a smoke detection system complying with S20C5.\nClass 3 buildings—\nwith a Class 3 part located more than 2 storeys above ground level — a smoke detection system complying with S20C4; or\nwhich accommodate more than 20 residents and are the residential part of a school, accommodation for the aged, children or people with a disability — a smoke detection system complying with S20C4; or\nall other Class 3 buildings—\na smoke alarm system complying with S20C3; or\na smoke detection system complying with S20C4; or\na combination of a smoke alarm system and a smoke detection system complying with S20C5.\nClass 5, 6, 7, 8, 9b and 9c buildings — a smoke detection system complying with S20C4\nClass 9a health-care buildings —\nwhere more than 6 bed patients are accommodated — a smoke detection system complying with S20C4; or\nwhere 6 or less bed patients are accommodated—\na smoke alarm system complying with S20C3; or\na smoke detection system complying with S20C4.","g":"/ncc/s20c2","a19":["Spec E2.2a: 2"]},{"c":"S20C3","t":"Smoke alarm system","p":"Specification 20 Smoke detection and alarm systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/20-smoke-detection-and-alarm-systems#S20C3","x":"(1) In all Class 2 to 9 buildings provided with a smoke alarm system, the following applies:\nA smoke alarm system must—\nconsist of smoke alarms complying with AS 3786; and\nbe powered from the consumer mains source.\nIn kitchens and other areas where the use of the area is likely to result in smoke alarms causing spurious signals, subject to (c)—\nany other alarm deemed suitable in accordance with AS 1670.1 may be installed provided that smoke alarms are installed elsewhere in the sole-occupancy unit in accordance with (2)(a) and (2)(b); or\nan alarm acknowledgement facility may be installed.\nWhere a kitchen or other area referred to in (b) is in a building protected with a sprinkler system complying with Specification 17 (other than a FPAA101D system), alarms need not be installed in the kitchen or other area likely to result in spurious signals.\n(2) In a Class 2 or 3 building or Class 4 part of a building provided with a smoke alarm system, the following applies:\nAlarms must be installed within each sole-occupancy unit, and located on or near the ceiling in any storey —\ncontaining bedrooms—\nbetween each part of the sole-occupancy unit containing bedrooms and the remainder of the sole-occupancy unit; and\nwhere bedrooms are served by a hallway, in that hallway; and\nnot containing any bedrooms, in egress paths.\nWhere there is more than one alarm installed within a sole-occupancy unit, alarms must be interconnected within that sole-occupancy unit.\nSubject to (d), alarms must be—\ninstalled in public corridors and other internal public spaces, located in accordance with the requirements for smoke detectors in AS 1670.1; and\nconnected to activate a building occupant warning system in accordance with S20C7.\nIn a Class 2 or 3 building or Class 4 part of a building protected with a sprinkler system complying with Specification 17 (other than a FPAA101D system), alarms are not required in public corridors and other internal public spaces.\n(3) In a Class 9a building provided with a smoke alarm system, smoke alarms must be—\ninstalled in every room, public corridor and other internal public space; and\nlocated in accordance with the requirements for smoke detectors in AS 1670.1; and\ninterconnected to provide a common alarm; and\nhave manual call points installed in evacuation routes so that no point on a floor is more than 30 m from a manual call point.","g":"/ncc/s20c3","a19":["Spec E2.2a: 3"]},{"c":"S20C4","t":"Smoke detection system","p":"Specification 20 Smoke detection and alarm systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/20-smoke-detection-and-alarm-systems#S20C4","x":"(1) In all Class 2 to 9 buildings provided with a smoke detection system, the following applies:\nA smoke detection system must—\nsubject to (2), (3) and (4), comply with AS 1670.1; and\nactivate a building occupant warning system in accordance with S20C7.\nIn kitchens and other areas where the use of the area is likely to result in smoke detectors causing spurious signals, subject to (c)—\nany other detector deemed suitable in accordance with AS 1670.1 may be installed provided that smoke detectors are installed elsewhere in the sole-occupancy unit in accordance with the requirements for alarms in S20C3(2)(a) and (2)(b); or\nan alarm acknowledgement facility may be installed.\nWhere a kitchen or other area referred to in (b) is in a building protected with a sprinkler system complying with Specification 17 (other than a FPAA101D or FPAA101H system), detectors need not be installed in the kitchen or other areas likely to result in spurious signals.\n(2) In a Class 2 or 3 building or Class 4 part of a building provided with a smoke detection system, the following applies:\nSmoke detectors must be installed—\nwithin each sole-occupancy unit, in accordance with the requirements for alarms in S20C3(2)(a) and (2)(b); and\nsubject to (b), in public corridors and other internal public spaces.\nIn a Class 2 or 3 building or Class 4 part of a building protected with a sprinkler system complying with Specification 17 (other than a FPAA101D or FPAA101H system), smoke detectors are not required in public corridors and other internal public spaces.\n(3) In a Class 9a health-care building provided with a smoke detection system, the following applies:\nExcept as provided in (b)—\nphotoelectric type smoke detectors must be installed in patient care areas and in paths of travel to exits from patient care areas; and\nin areas other than patient care areas and paths of travel to exits from patient care areas, where the use of the area is likely to result in smoke detectors causing spurious signals, any other detector deemed suitable in accordance with AS 1670.1 may be installed in lieu of smoke detectors.\nThe requirements of (a) do not apply where an area is protected with a sprinkler system complying with Specification 17, smoke detectors need not be installed where the use of the area is likely to result in spurious signals.\nManual call points must be installed in evacuation routes so that no point on a floor is more than 30 m from a manual call point.\n(4) In a Class 9c building provided with a smoke detection system, the following applies:\nremote automatic indication of each zone must be given in each smoke compartment by means of—\nmimic panels with an illuminated display; or\nannunciator panels with alpha numeric display; and\nif the building accommodates more than 20 residents, manual call points must be installed in paths of travel so that no point on a floor is more than 30 m from a manual call point.","g":"/ncc/s20c4","a19":["Spec E2.2a: 4"]},{"c":"S20C5","t":"Combined smoke alarm and smoke detection system","p":"Specification 20 Smoke detection and alarm systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/20-smoke-detection-and-alarm-systems#S20C5","x":"(1) A Class 2 or 3 building or Class 4 part of a building provided with a combination of a smoke alarm system and smoke detection system in accordance with S20C2 must—\nbe provided with a smoke alarm system complying with S20C3 within sole-occupancy units; and\nsubject to (2), be provided with a smoke detection system complying with S20C4 in areas not within sole-occupancy units.\n(2) In a Class 2 or 3 building or Class 4 part of a building protected with a sprinkler system complying with Specification 17 (other than a FPAA101D or FPAA101H system), smoke detectors are not required in public corridors and other internal public spaces.","g":"/ncc/s20c5","a19":["Spec E2.2a: 5"]},{"c":"S20C6","t":"Smoke detection for smoke control systems","p":"Specification 20 Smoke detection and alarm systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/20-smoke-detection-and-alarm-systems#S20C6","x":"(1) Smoke detectors required to activate air pressurisation systems for fire-isolated exits and zone pressurisation systems must—\nbe installed in accordance with Section 7 of AS 1670.1; and\nhave additional smoke detectors installed adjacent to each bank of lift landing doors set back horizontally from the door openings by a distance of not more than 3 m.\n(2) Smoke detectors required to activate—\nautomatic shutdown of air-handling systems in accordance with E2D16, E2D17 or E2D19; or\na smoke exhaust system in accordance with Specification 21,\nmust comply with the requirements of (3).\n(3) Smoke detectors referred to in (2) must—\nbe spaced—\nnot more than 20 m apart and not more than 10 m from any wall, bulkhead or smoke curtain; and\nin enclosed malls and walkways in a Class 6 building not more than 15 m apart and not more than 7.5 m from any wall, bulkhead or curtain; and\nhave a sensitivity—\nin accordance with Section 7 of AS 1670.1 in areas other than a multi-storey walkway and mall in a Class 6 building; and\nnot exceeding 0.5% smoke obscuration per metre with compensation for external airborne contamination as necessary, in a multi-storey walkway and mall in a Class 6 building.\n(4) Smoke detectors provided to activate a smoke control system must—\neither—\nform part of a building fire or smoke detection system complying with AS 1670.1; or\nbe a separate dedicated system incorporating control and indicating equipment complying with AS 1670.1; and\nactivate a building occupant warning system complying with S20C7, except that smoke detectors provided solely to initiate automatic shutdown of air-handling systems in accordance with (2)(a) need not activate a building occupant warning system.","g":"/ncc/s20c6","a19":["Spec E2.2a: 6"]},{"c":"S20C7","t":"Building occupant warning system","p":"Specification 20 Smoke detection and alarm systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/20-smoke-detection-and-alarm-systems#S20C7","x":"Subject to E4D9, a building occupant warning system provided as part of a smoke hazard management system must comply with clause 3.17 of AS 1670.1 to sound through all occupied areas except—\nin a Class 2 and 3 building or Class 4 part of a building provided with a smoke alarm system in accordance with S20C3(2)(c) —\nthe sound pressure level need not be measured within a sole-occupancy unit if a level of not less than 85 dB(A) is provided at the door providing access to the sole-occupancy unit; and\nthe inbuilt sounders of the smoke alarms may be used to wholly or partially meet the requirements; and\nin a Class 2 and 3 building or Class 4 part of a building provided with a smoke detection system in accordance with S20C4(2), the sound pressure level from a building occupant warning system need not be measured within a sole-occupancy unit if a level of not less than 100 dB(A) is provided at the door providing access to the sole-occupancy unit; and\nin a Class 3 building used as a residential care building, the system—\nmust be arranged to provide a warning for occupants; and\nin areas used by residents, may have its alarm adjusted in volume and content to minimise trauma consistent with the type and condition of residents; and\nin a Class 9a health-care building, in a patient care area, the system—\nmust be arranged to provide a warning for occupants; and\nin a ward area, may have its alarm adjusted in volume and content to minimise trauma consistent with the type and condition of the patients; and\nin a Class 9c building, the system—\nmust be arranged to provide a warning for occupants; and\nmust notify staff caring for the residents of the building; and\nin areas used by residents, may have its alarm adjusted in volume and content to minimise trauma consistent with the type and condition of residents.","g":"/ncc/s20c7","a19":["Spec E2.2a: 7"]},{"c":"S20C8","t":"System monitoring","p":"Specification 20 Smoke detection and alarm systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/20-smoke-detection-and-alarm-systems#S20C8","x":"The following installations must be connected to a fire alarm monitoring system connected to a fire station or fire station dispatch centre in accordance with AS 1670.3:\nA smoke detection system in a Class 3 building provided in accordance with S20C2(b)(i) or S20C2(b)(ii).\nA smoke detection system in a Class 9a health-care building, if the building accommodates more than 20 patients.\nA smoke detection system in a Class 9c building.\nSmoke detection in accordance with S20C6 provided to activate—\na smoke exhaust system in accordance with Specification 21; or\nsmoke-and-heat vents in accordance with Specification 22.\nAn automatic fire detection and alarm system required by E2D10 for large isolated buildings subject to C3D4.","g":"/ncc/s20c8","a19":["VIC Spec E2.2a: 8","NSW Spec E2.2a: 8","Spec E2.2a: 8"]},{"c":"S21C1","t":"Scope","p":"Specification 21 Smoke exhaust systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/21-smoke-exhaust-systems#S21C1","x":"This Specification describes the requirements for mechanical smoke exhaust systems.","g":"/ncc/s21c1","a19":["Spec E2.2b: 1"]},{"c":"Table S21C2","t":"Fire load (MW)","p":"Specification 21 Smoke exhaust systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/21-smoke-exhaust-systems#_6b061710-5afc-4a6b-a0e0-1c6e58509d81","x":"Classification | Fire load (MW) for unsprinklered buildings | Fire load (MW) for sprinklered buildings\nClass 2, 3 or 5 | 5 | 1.5\nClass 6 | 10 | 5\nClass 7 or 8 | 15 | 5\nClass 9 — generally | 5 | 1.5\nClass 9b buildings covered by Part I1 (see Note) or exhibition halls | 10 | 5\nTable Notes\nIf the smoke reservoir above the stage is smoke separated from the audience area, the fire load specified applies to the stage area only and the fire load for the audience area is as per Class 9 generally.","tb":"S21C2","g":"/ncc/table-s21c2"},{"c":"S21C2","t":"Smoke exhaust capacity","p":"Specification 21 Smoke exhaust systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/21-smoke-exhaust-systems#S21C2","x":"(1) Smoke exhaust fans must have a sufficient capacity to contain the smoke layer—\nwithin a smoke reservoir formed in accordance with S21C4 and not less than 2 m above the highest floor level; and\nabove the top of any openings interconnecting different smoke reservoirs.\n(2) Exhaust rates must be determined in accordance with Figure S21C2, with the height measurement taken from the lowest floor level to the underside of the smoke layer and the fire load determined in accordance with Table S21C2.\nTable S21C2 Fire load (MW)\nClassification\nFire load (MW) for unsprinklered buildings\nFire load (MW) for sprinklered buildings\nClass 2, 3 or 5\n5\n1.5\nClass 6\n10\n5\nClass 7 or 8\n15\n5\nClass 9 — generally\n5\n1.5\nClass 9b buildings covered by Part I1 (see Note) or exhibition halls\n10\n5\nTable Notes\nIf the smoke reservoir above the stage is smoke separated from the audience area, the fire load specified applies to the stage area only and the fire load for the audience area is as per Class 9 generally.\nFigure S21C2 Smoke exhaust rate","g":"/ncc/s21c2","a19":["Spec E2.2b: 2"]},{"c":"S21C3","t":"Smoke exhaust fans","p":"Specification 21 Smoke exhaust systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/21-smoke-exhaust-systems#S21C3","x":"Each smoke exhaust fan, complete with its drive, flexible connections, control gear and wiring must—\nbe constructed and installed so that it is capable of continuous operation (exhausting the required volumetric flow rate at the installed system resistance) at a temperature of 200°C for a period of not less than 1 hour; and\nin a building not fitted with a sprinkler system, be capable of continuous operation at a temperature of 300°C for a period of not less than 30 minutes; and\nbe rated to handle the required volumetric flow rate at ambient temperature to be capable of exhausting cool smoke during the early stages of a fire and to allow routine testing; and\nhave any high temperature overload devices installed, automatically overridden during the smoke exhaust operation.","g":"/ncc/s21c3","a19":["Spec E2.2b: 3"]},{"c":"S21C4","t":"Smoke reservoirs","p":"Specification 21 Smoke exhaust systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/21-smoke-exhaust-systems#S21C4","x":"(1) A fire compartment must be divided at ceiling level into smoke reservoirs formed by smoke baffles/curtains of non-combustible and non-shatterable construction.\n(2) The horizontal area of a smoke reservoir must not exceed 2000 m2 and in enclosed walkways and malls of a Class 6 building must not exceed 60 m in length.\n(3) Smoke reservoirs must be of sufficient depth to contain the smoke layer and must not be less than 500 mm below an imperforate ceiling or roof.\n(4) Within a multi-storey fire compartment —\na non-combustible bulkhead or smoke baffle/curtain must be provided around the underside of each opening into a building void to minimise the spread of smoke to other storeys; and\nthe depth of the bulkhead or smoke baffle must be not less than the depth of the smoke reservoir provided under (3) plus an additional 400 mm.","g":"/ncc/s21c4","a19":["Spec E2.2b: 4"]},{"c":"S21C5","t":"Smoke exhaust fan and vent location","p":"Specification 21 Smoke exhaust systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/21-smoke-exhaust-systems#S21C5","x":"Smoke exhaust fans and vents must be located—\nsuch that each smoke reservoir is served by one or more fans with the maximum exhaust rate at any one point limited to avoid extracting air from below the smoke layer; and\nto prevent the formation of stagnant regions resulting in excessive cooling and downward mixing of smoke; and\nat natural collection points for the hot smoky gases within each smoke reservoir having due regard to the ceiling geometry and its effect on the migratory path of the smoke; and\naway from the intersection of walkways or malls; and\nto ensure that any voids containing escalators and/or stairs commonly used by the public are not used as a smoke exhaust path; and\nto discharge directly to outdoor with a velocity of not less than 5 m/s, at a suitable point not less than 6 m from any air intake point or exit.","g":"/ncc/s21c5","a19":["Spec E2.2b: 5"]},{"c":"S21C6","t":"Make-up air","p":"Specification 21 Smoke exhaust systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/21-smoke-exhaust-systems#S21C6","x":"(1) Low level make-up air must be provided either automatically or via permanent ventilation openings to replace the air exhausted so as to minimise—\nany disturbance of the smoke layer due to turbulence created by the incoming air; and\nthe risk of smoke migration to areas remote from the fire due to the effect of make-up air on the air balance of the total system.\n(2) The velocity of make-up air through doorways must not exceed 2.5 m/s.\n(3) Within a multi-storey fire compartment, make-up air must be provided across each vertical opening from a building void to the fire-affected storey at an average velocity of 1 m/s so as to minimise the spread of smoke from the fire-affected storey to other storeys.","g":"/ncc/s21c6","a19":["Spec E2.2b: 6"]},{"c":"S21C7","t":"Smoke exhaust system control","p":"Specification 21 Smoke exhaust systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/21-smoke-exhaust-systems#S21C7","x":"(1) Each smoke exhaust fan must be activated sequentially by smoke detectors complying with Specification 20 and arranged in zones to match the smoke reservoir served by the fan(s).\n(2) Subject to (3) and (4), an air handling system (other than individual room units less than 1000 L/s and ventilation systems installed in accordance with Sections 5 and 6 of AS 1668.1) which does not form part of the smoke hazard management system must be automatically shut down on the activation of the smoke exhaust system.\n(3) In a single storey fire compartment, air handling systems in all non fire-affected zones may operate on 100% outdoor air to provide make-up air to the fire-affected zone.\n(4) Within a multi-storey fire compartment, air handling systems in all non fire-affected zones and storeys must operate at 100% outdoor air to provide make-up air to the fire-affected storey via building voids connecting storeys.\n(5) Manual override control and indication together with operating instructions for use by emergency personnel must be provided adjacent to the fire indicator panel in accordance with the control and indication requirements and the smoke control operating instructions of AS 1668.1.\n(6) Manual control for the smoke exhaust system must also be provided at a location normally used by the stage manager in a theatre.\n(7) Electrical installations, including power supply wiring to exhaust fans together with detection, control indication circuits (and where necessary, automatic make-up air supply) must comply with the requirements of AS 1668.1.","g":"/ncc/s21c7","a19":["Spec E2.2b: 7"]},{"c":"S21C8","t":"Smoke detection","p":"Specification 21 Smoke exhaust systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/21-smoke-exhaust-systems#S21C8","x":"A smoke detection system must be installed in accordance with Specification 20 to activate the smoke exhaust system.","g":"/ncc/s21c8","a19":["Spec E2.2b: 8"]},{"c":"S22C1","t":"Scope","p":"Specification 22 Smoke-and-heat vents","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/22-smoke-and-heat-vents#S22C1","x":"This Specification contains requirements for automatic smoke-and-heat vents.","g":"/ncc/s22c1"},{"c":"S22C2","t":"Adoption of AS 2665","p":"Specification 22 Smoke-and-heat vents","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/22-smoke-and-heat-vents#S22C2","x":"Automatic smoke-and-heat vents must be installed as a system complying with AS 2665 except that permanently open vents may form part of the smoke/heat venting system provided they comply with the relevant criteria for automatic smoke-and-heat vents in AS 2665.","g":"/ncc/s22c2","a19":["Spec E2.2c: 1"]},{"c":"S22C3","t":"Controls","p":"Specification 22 Smoke-and-heat vents","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/22-smoke-and-heat-vents#S22C3","x":"Where a smoke-and-heat vent system is installed to comply with E2D14 to E2D20, then, in addition to thermally released link operation, smoke-and-heat vents must also be initiated by smoke detection complying with S20C6 and S20C8 and arranged in zones to match the smoke reservoirs.","g":"/ncc/s22c3","a19":["Spec E2.2c: 2"]},{"c":"S23C1","t":"Scope","p":"Specification 23 Residential fire safety systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/23-residential-fire-safety-systems#S23C1","x":"This Specification describes the requirements for residential fire safety systems referenced in Specification 18.","g":"/ncc/s23c1","a19":["Spec E2.2d: 1"]},{"c":"S23C2","t":"Application","p":"Specification 23 Residential fire safety systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/23-residential-fire-safety-systems#S23C2","x":"(1) Clauses S23C3 to S23C7 —\napply to Class 3 residential care buildings; and\ncover installation requirements for local fire indicator panels (or alarm panels) that provide information to staff when a fire alarm is activated.\n(2) Clauses S23C8 and S23C9 describe requirements for connecting residential sprinkler systems in Class 2 and 3 buildings, or a residential care building, to a fire station or other approved monitoring service.","g":"/ncc/s23c2","a19":["Spec E2.2d: 1"]},{"c":"S23C3","t":"General requirements","p":"Specification 23 Residential fire safety systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/23-residential-fire-safety-systems#S23C3","x":"(1) The installation of a residential local fire alarm system must consist of a system of smoke alarms powered either—\ndirectly from the low voltage supply mains; or\nfrom an extra-low voltage power source originating at a local fire indicator panel with a battery back-up facility.\n(2) A smoke detector complying with AS 1670.1 Clause 2.1.2(a)(ii), (xi) or (xv) may be substituted for a smoke alarm, provided an audible alarm device is associated with each detector.\n(3) The sound pressure level provided by a warning device must be equivalent to that required in Clause 3.22 of AS 1670.1, except that the sound pressure level need not be measured inside a sole-occupancy unit, provided that a level of not less than 85 dB(A) is attained at the access door to the unit.\n(4) The alarm system must be wired for low voltage or extra-low voltage wiring.\n(5) The system must be designed so—\nan audible alarm is given in the area in which the smoke alarm activates; and\nvisible and audible indication of an alarm is provided at the local fire indicator panel; and\nan audible alarm is given in any area (including sleeping quarters and staff outbuildings) set aside for staff use.\n(6) The maximum number of smoke alarms on any one alarm zone must—\nbe determined by the maximum current output rating of the system source; and\nnot exceed 10.\n(7) Each alarm zone must be located around a single central access passageway, corridor or similar thoroughfare, to enable staff to readily identify the source of the alarm.\n(8) Where the smoke alarm is functionally dependent on an external power source—\nan audible fault signal must sound at the local fire indicator panel if that power source fails; and\nthe local fire indicator panel must be permanently connected to a reliable 240 V separate low voltage final sub-circuit; and\nsource power must be protected by a separate circuit breaker, or fuse, supplied from the live side of the main switch.\n(9) The smoke alarm system is not required to be connected to a fire alarm monitoring system (refer to S18C3(2)(c)).","g":"/ncc/s23c3","a19":["Spec E2.2d: 2(a)"]},{"c":"S23C4","t":"Local fire indicator panel","p":"Specification 23 Residential fire safety systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/23-residential-fire-safety-systems#S23C4","x":"(1) The local fire indicator panel must be located in a central area, such as a reception area, so that it is readily accessible by staff at all times.\n(2) The local fire indicator panel must be fixed wired.\n(3) The local fire indicator panel must incorporate the following:\nA suitable mains power supply with battery back-up (capable of operating the system for 12 hours) for the local fire indicator panel and extra-low voltage smoke alarms supplied directly from the local fire indicator panel.\nTerminals for input signal conductors from the smoke alarm and residential sprinkler system and, if the signal source is from a low voltage smoke alarm, external isolation must be provided.\nVisible indication of the alarm zone in which the actuating device is located.\nAutomatic audible and visible indication of the following faults:\nA break in the wiring of any circuit between smoke alarms or sprinkler alarm switch and the local fire indicator panel.\nLow battery condition.\nAutomatic visible indication of mains power failure.\nInitiation of any ancillary control facilities such as smoke door release or air-conditioning shut-down.\nLocal operation of individual smoke alarms, in the event of alarm zone isolation at the local fire indicator panel.\n(4) If the local fire indicator panel is also used for other non-fire related purposes such as security, then these functions—\nmust be on separate and distinct circuits; and\nwhen disabled or isolated, must not interfere with the operation of fire alarm circuitry.\n(5) The local fire indicator panel must comply with AS 1670.1.\n(6) The local fire indicator panel must have the capacity to incorporate heat detectors deemed suitable in accordance with AS 1670.1 on either the same or separate alarm zones as the smoke alarms.","g":"/ncc/s23c4","a19":["Spec E2.2d: 2(b)"]},{"c":"S23C5","t":"Smoke alarms","p":"Specification 23 Residential fire safety systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/23-residential-fire-safety-systems#S23C5","x":"(1) Extra-low voltage smoke alarms must be compatible with the local fire indicator panel.\n(2) Low voltage smoke alarms must be configured to send an output alarm signal to the local fire indicator panel.\n(3) Unless there is internal isolation of the signal output conductors, they must at all times be treated as low voltage conductors.","g":"/ncc/s23c5","a19":["Spec E2.2d: 2(c)"]},{"c":"S23C6","t":"Signal isolation interface units","p":"Specification 23 Residential fire safety systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/23-residential-fire-safety-systems#S23C6","x":"(1) Signal isolation interface units must isolate any low voltage connected to the smoke alarms from the local fire indicator panel.\n(2) Signal isolation interface units must be certified by an Accredited Testing Laboratory as compatible with the specific types of smoke alarms used in the system.\n(3) Signal isolation interface units must be accepted by the electricity supply authority.\n(4) Units must be marked in a clearly visible location, with letters greater than or equal to 35 mm containing the following information:\nSMOKE ALARM SIGNAL ISOLATION UNIT WARNING – 240 V\nIsolate power supply before removing cover","g":"/ncc/s23c6","a19":["Spec E2.2d: 2(d)"]},{"c":"S23C7","t":"Wiring","p":"Specification 23 Residential fire safety systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/23-residential-fire-safety-systems#S23C7","x":"(1) Smoke alarms and associated equipment must be fixed wired for low voltage or extra-low voltage wiring systems, as applicable.\n(2) All extra-low voltage wiring must be red sheathed 0.6/1 kV stranded, with conductors having a cross sectional area of not less than 0.75 mm2.\n(3) Clear and concise \"as-installed\" single line drawings to a suitable scale, showing rooms, external and internal walls, fixed partitions, doorways etc., are to be provided for each installation at the local fire indicator panel.\n(4) Drawings must also include the actual location of fire alarms, smoke alarms, sprinkler flow switches (where installed), alarm connection points and local fire indicator panel, to enable easy identification of alarm system elements and their relationship to the building layout.\n(5) Symbols used in the drawings referred to in (4) must be as shown in Figures S23C7a, S23C7b, S23C7c, S23C7d, S23C7e or S23C7f.\nFigure S23C7a Flow switch symbol\nFigure S23C7b Heat detector symbol\nFigure S23C7c Smoke detector symbol\nFigure S23C7d End-of-line device symbol\nFigure S23C7e Fire indicator panel symbol\nFigure S23C7f Smoke alarm symbol","g":"/ncc/s23c7","a19":["Spec E2.2d: 2(e)"]},{"c":"S23C8","t":"Connection to monitoring service","p":"Specification 23 Residential fire safety systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/23-residential-fire-safety-systems#S23C8","x":"(1) Connection of a residential sprinkler system to a fire station or other approved monitoring service must be via a sprinkler alarm switch, connected to alarm signalling equipment.\n(2) The connection from the alarm signalling equipment must be in accordance with AS 1670.3.\n(3) The alarm signalling equipment must be installed—\nin a secure, accessible position; and\nin a weatherproof housing, if located externally; and\nnot more than 500 mm from the system flow switch.","g":"/ncc/s23c8","a19":["Spec E2.2d: 3(a)"]},{"c":"S23C9","t":"Indication at the fire indicator panel","p":"Specification 23 Residential fire safety systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/23-residential-fire-safety-systems#S23C9","x":"The fire signal from the alarm signalling equipment must be mimicked by an audible and visible signal at the fire indicator panel.","g":"/ncc/s23c9","a19":["Spec E2.2d: 3(b)"]},{"c":"S24C1","t":"Scope","p":"Specification 24 Lift installations","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/24-lift-installations#S24C1","x":"This Specification contains requirements for electric passenger lift installations and electrohydraulic passenger lift installations.","g":"/ncc/s24c1","a19":["Spec E3.1: 1"]},{"c":"S24C2","t":"Lift cars exposed to solar radiation","p":"Specification 24 Lift installations","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/24-lift-installations#S24C2","x":"(1) A lift car exposed to solar radiation directly, or indirectly by re-radiation, must have—\nmechanical ventilation at a rate of one air change per minute; or\nmechanical cooling.\n(2) A 2 hour alternative power source for ventilation or mechanical cooling at (1) must be provided in the event of normal power loss.","g":"/ncc/s24c2","a19":["Spec E3.1: 2"]},{"c":"S24C3","t":"Lift car emergency lighting","p":"Specification 24 Lift installations","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/24-lift-installations#S24C3","x":"A lift car must have an emergency lighting system designed—\nto come on automatically upon failure of the normal lighting supply; and\nto provide at least 20 lux of lighting for 2 hours on the alarm initiation button.","g":"/ncc/s24c3","a19":["Spec E3.1: 3"]},{"c":"S24C4","t":"Cooling of lift shaft","p":"Specification 24 Lift installations","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/24-lift-installations#S24C4","x":"While a lift in a lift shaft is in service, the cooling of the lift shaft must—\nensure that the dry bulb air temperature in the lift shaft does not exceed 40°C; and\nif the cooling is by a ventilation system, be provided with an air change rate determined using a temperature rise of no more than 5 K.","g":"/ncc/s24c4","a19":["Spec E3.1: 4"]},{"c":"S24C5","t":"Lift foyer access","p":"Specification 24 Lift installations","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/24-lift-installations#S24C5","x":"Where there is a security foyer in a building, access may be via locked security doors provided—\nsecurity doors revert to the unlocked state in the event of—\npower failure; or\nfire alarm; and\nlocked foyer areas are monitored by closed circuit television and intercom system to a 24 hour staffed location.","g":"/ncc/s24c5","a19":["Spec E3.1: 5"]},{"c":"S24C6","t":"Emergency access doors in enclosed lift shafts","p":"Specification 24 Lift installations","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/24-lift-installations#S24C6","x":"(1) Where lifts are installed in enclosed lift shafts, having a distance between normal landing entrances greater than 11 m, emergency access doors must be provided and constructed as follows:\nThe clear opening size of emergency doors must be not less than 600 mm wide x 2 m high.\nHinged doors must not open towards the interior of the lift shaft.\nDoors must be self-closing and self-locking.\nDoors must be marked on the landing side with the following words in letters not less than 35 mm high:\nDANGER LIFTWELL ACCESS\nKEEP FURNITURE AND FIXTURES CLEAR\nDoors from the landing side must only be openable by a tool.\nEach emergency door must be provided with a positive breaking electrical contact, wired into the control circuit to prevent movement of the lift until the emergency door is both closed and locked.\n(2) Emergency egress from the lift car must be provided in single enclosed lift shafts where—\nropes are installed; and\nthe vertical distance between the lift car sill and the landing door head is less than 600 mm; and\nthe counterweight is resting on its fully compressed buffer.\n(3) Emergency egress required by (2) must be in the form of an interlocked door with clear opening dimensions not less than 600 mm x 600 mm, accessible from the lift car entrance or the lift car roof (where the door is located in the wall of the lift shaft).","g":"/ncc/s24c6","a19":["Spec E3.1: 6"]},{"c":"S25C1","t":"Scope","p":"Specification 25 Passive photoluminescent exit signs","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/25-passive-photoluminescent-exit-signs#S25C1","x":"This Specification contains requirements for passive photoluminescent exit signs.","g":"/ncc/s25c1","a19":["Spec E4.8: 1"]},{"c":"S25C2","t":"Application","p":"Specification 25 Passive photoluminescent exit signs","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/25-passive-photoluminescent-exit-signs#S25C2","x":"A passive photoluminescent exit sign must comply with Section 5 and Appendix D of AS/NZS 2293.1, except where varied by this Specification.","g":"/ncc/s25c2","a19":["Spec E4.8: 2"]},{"c":"S25C3","t":"Illumination","p":"Specification 25 Passive photoluminescent exit signs","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/25-passive-photoluminescent-exit-signs#S25C3","x":"A passive photoluminescent exit sign must—\nbe maintained in a continuously charged state by a minimum illumination of 100 lux at the face of the sign by a dedicated light source with a colour temperature not less than 4000 K; and\nin the event of a power failure, continue to provide a minimum luminance of 30 mcd/m2 for not less than 90 minutes; and\nhave its performance verified by testing in accordance with ASTM E2073-10, except the activation illumination in clause 8.3 is replaced with 54 lux.","g":"/ncc/s25c3","a19":["Spec E4.8: 3"]},{"c":"S25C4","t":"Pictorial elements","p":"Specification 25 Passive photoluminescent exit signs","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/25-passive-photoluminescent-exit-signs#S25C4","x":"Pictorial elements on a passive photoluminescent exit sign must—\nwhere the colour white is used, be replaced with a photoluminescent material; and\nbe not less than 1.3 times larger than that specified in Table 5.1 of AS/NZS 2293.1; and\nhave a border of photoluminescent material that extends not less than 15 mm beyond the pictorial elements.","g":"/ncc/s25c4","a19":["Spec E4.8: 4"]},{"c":"S25C5","t":"Viewing distance","p":"Specification 25 Passive photoluminescent exit signs","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/25-passive-photoluminescent-exit-signs#S25C5","x":"The maximum viewing distance in clause 5.6 of AS/NZS 2293.1 must not be more than 24 m.","g":"/ncc/s25c5","a19":["Spec E4.8: 5"]},{"c":"S25C6","t":"Smoke control systems","p":"Specification 25 Passive photoluminescent exit signs","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/25-passive-photoluminescent-exit-signs#S25C6","x":"Smoke control systems required by clause 5.3 of AS/NZS 2293.1 do not apply to a passive photoluminescent exit sign.","g":"/ncc/s25c6","a19":["Spec E4.8: 6"]},{"c":"E1O1","t":"Objective","p":"Part E1 Fire fighting equipment","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e1-fire-fighting-equipment#E1O1","x":"The Objective of this Part is to—\nsafeguard occupants from illness or injury while evacuating during a fire; and\nprovide facilities for occupants and the fire brigade to undertake fire-fighting operations; and\nprevent the spread of fire between buildings.","g":"/ncc/e1o1","a19":["EO1"]},{"c":"E1F1","t":"Fire-fighting equipment","p":"Part E1 Fire fighting equipment","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e1-fire-fighting-equipment#E1F1","x":"A building is to be provided with fire-fighting equipment to safeguard against fire spread—\nto allow occupants time to evacuate safely without being overcome by the effects of fire; and\nso that occupants may undertake initial attack on a fire; and\nso that the fire brigade have the necessary equipment to undertake search, rescue and fire-fighting operations; and\nto other parts of the building; and\nbetween buildings.","g":"/ncc/e1f1","a19":["EF1.1"]},{"c":"E1P1","t":"Fire hose reels","p":"Part E1 Fire fighting equipment","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e1-fire-fighting-equipment#E1P1","x":"A fire hose reel system must be installed to the degree necessary to allow occupants to safely undertake initial attack on a fire appropriate to—\nthe size of the fire compartment; and\nthe function or use of the building; and\nany other fire safety systems installed in the building; and\nthe fire hazard.","g":"/ncc/e1p1","a19":["EP1.1"]},{"c":"E1P2","t":"Fire extinguishers","p":"Part E1 Fire fighting equipment","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e1-fire-fighting-equipment#E1P2","x":"Fire extinguishers must be installed to the degree necessary to allow occupants to undertake initial attack on a fire appropriate to—\nthe function or use of the building; and\nany other fire safety systems installed in the building; and\nthe fire hazard.","g":"/ncc/e1p2","a19":["EP1.2"]},{"c":"E1P3","t":"Fire hydrants","p":"Part E1 Fire fighting equipment","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e1-fire-fighting-equipment#E1P3","x":"A fire hydrant system must be provided to the degree necessary to facilitate the needs of the fire brigade appropriate to—\nfire-fighting operations; and\nthe floor area of the building; and\nthe fire hazard.\nApplications\nE1P3 only applies to a building where a fire brigade is available to attend.","g":"/ncc/e1p3","a19":["EP1.3"]},{"c":"E1P4","t":"Automatic fire suppression systems","p":"Part E1 Fire fighting equipment","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e1-fire-fighting-equipment#E1P4","x":"An automatic fire suppression system must be installed to the degree necessary to control the development and spread of fire appropriate to—\nthe size of the fire compartment; and\nthe function or use of the building; and\nthe fire hazard; and\nthe height of the building.","g":"/ncc/e1p4","a19":["EP1.4"]},{"c":"E1P5","t":"Fire-fighting services in buildings under construction","p":"Part E1 Fire fighting equipment","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e1-fire-fighting-equipment#E1P5","x":"Suitable means of fire-fighting must be installed to the degree necessary in a building under construction to allow initial fire attack by construction workers and for the fire brigade to undertake attack on the fire appropriate to—\nthe fire hazard; and\nthe height the building has reached during its construction.","g":"/ncc/e1p5","a19":["EP1.5"]},{"c":"E1P6","t":"Fire control centres","p":"Part E1 Fire fighting equipment","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e1-fire-fighting-equipment#E1P6","x":"Suitable facilities must be provided to the degree necessary in a building to co-ordinate fire brigade intervention during an emergency appropriate to—\nthe function or use of the building; and\nthe floor area of the building; and\nthe height of the building.","g":"/ncc/e1p6","a19":["EP1.6"]},{"c":"E1V1","t":"Fire Safety Verification Method","p":"Part E1 Fire fighting equipment","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e1-fire-fighting-equipment#E1V1","x":"Compliance with E1P1, E1P2, E1P3, E1P4 and E1P6 is verified when a building is designed in accordance with C1V4.","g":"/ncc/e1v1","a19":["EV1.1"]},{"c":"E1D1","t":"Deemed-to-Satisfy Provisions","p":"Part E1 Fire fighting equipment","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e1-fire-fighting-equipment#E1D1","x":"(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements E1P1 to E1P6 are satisfied by complying with—\nE1D2 to E1D17; and\nin a building containing an atrium, Part G3; and\nin a building in an alpine area, Part G4; and\nfor a building containing an occupiable outdoor area, Part G6; and\nfor additional requirements for Class 9b buildings, Part I1; and\nfor farm buildings and farm sheds, Part I3.\n(2) Where a Performance Solution is proposed, the relevant Performance Requirements must be determined in accordance with A2G2(3) and A2G4(3) as applicable.","g":"/ncc/e1d1","a19":["TAS E1.0","E1.0"]},{"c":"E1D2","t":"Fire hydrants","p":"Part E1 Fire fighting equipment","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e1-fire-fighting-equipment#E1D2","x":"(1) A fire hydrant system must be provided to serve a building—\nhaving a total floor area greater than 500 m2; and\nwhere a fire brigade station is—\nno more than 50 km from the building as measured along roads; and\nequipped with equipment capable of utilising a fire hydrant.\n(2) The fire hydrant system must be installed in accordance with—\nAS 2419.1; or\nAS 2118.6, where applicable; or\nFPAA101H, where applicable.\n(3) Notwithstanding—\n2(a), a Class 8 electricity network substation need not comply with clause 4.1.2 of AS 2419.1 if—\nit cannot be connected to a town main supply; and\none hour water storage is provided for fire-fighting; and\n2(b), plastic pipes and fittings must not be used above-ground in combined sprinkler and hydrant systems.\n(4) Where internal fire hydrants are provided, they must serve only the storey on which they are located except that a sole-occupancy unit —\nin a Class 2 or 3 building or Class 4 part of a building may be served by a single fire hydrant located at the level of egress from that sole-occupancy unit; or\nof not more than 2 storeys in a Class 5, 6, 7, 8 or 9 building may be served by a single fire hydrant located at the level of egress from that sole-occupancy unit provided the fire hydrant can provide coverage to the whole of the sole-occupancy unit.","g":"/ncc/e1d2","a19":["E1.3"]},{"c":"E1D3","t":"Fire hose reels","p":"Part E1 Fire fighting equipment","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e1-fire-fighting-equipment#E1D3","x":"(1) E1D3 does not apply to—\na Class 2, 3 or 5 building or Class 4 part of a building; or\na Class 8 electricity network substation; or\na Class 9c building; or\nclassrooms and associated corridors in a primary or secondary school; or\nareas less than 100m2—\nwhich are separated from other parts of the building by construction having an FRL of not less than 60/60/60; and\nwith any door in the construction required by (i) protected with a self-closing or automatic closing fire door having an FRL of not less than –/60/30; and\nwhich are provided with fire extinguishers in accordance with AS 2444 located on the egress side of an entry door to the space.\n(2) A fire hose reel system must be provided—\nto serve the whole building where one or more internal fire hydrants are installed; or\nwhere internal fire hydrants are not installed, to serve any fire compartment with a floor area greater than 500 m2.\n(3) The fire hose reel system must—\nhave fire hose reels installed in accordance with AS 2441; and\nprovide fire hose reels to serve only the storey at which they are located, except a sole-occupancy unit of not more than 2 storeys in a Class 6, 7, 8 or 9 building may be served by a single fire hose reel located at the level of egress from that sole-occupancy unit provided the fire hose reel can provide coverage to the whole of the sole-occupancy unit.\n(4) Fire hose reels must be located internally, externally or in combination, to achieve the system coverage specified in AS 2441.\n(5) In achieving system coverage, one or a combination of the following criteria for individual internally located fire hose reels must be met in determining the layout of any fire hose reel system:\nFire hose reels must be located adjacent to an internal fire hydrant (other than one within a fire-isolated exit), except that a fire hose reel need not be located adjacent to every fire hydrant, provided system coverage can be achieved.\nFire hose reels must be located within 4 m of an exit, except that a fire hose reel need not be located adjacent to every exit, provided system coverage can be achieved.\nWhere system coverage is not achieved by compliance with (a) and (b), additional fire hose reels may be located in paths of travel to an exit to achieve the required coverage.\n(6) Fire hose reels must be located so that the fire hose will not need to pass through doorways fitted with fire or smoke doors, except—\ndoorways in walls referred to in C3D6(1)(e) in a Class 9a building and C3D6(3)(d) in a Class 9c building, separating ancillary use areas of high potential fire hazard; and\ndoorways in walls referred to in C3D13 or C3D14 separating equipment or electrical supply systems; and\ndoorway openings to shafts referred to in C4D14.\n(7) Where the normal water supply cannot achieve the flow and pressures required by AS 2441, or is unreliable—\na pump; or\nwater storage facility; or\nboth a pump and water storage facility,\nmust be installed to provide the minimum flow and pressures required by clause 6.1 of AS 2441.","g":"/ncc/e1d3","a19":["E1.4"]},{"c":"E1D4","t":"Sprinklers","p":"Part E1 Fire fighting equipment","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e1-fire-fighting-equipment#E1D4","x":"A sprinkler system must—\nbe installed in a building or part of a building when required by E1D5 to E1D13 as applicable; and\ncomply with Specification 17 and Specification 18 as applicable.\nNotes\nSee Specification 5 for use of sprinklers in Class 2 buildings and carparks generally.\nSee Part E2 for use of sprinklers to satisfy smoke hazard management provisions.\nSee C2D13 and Specification 5 for use of sprinklers in buildings where C2D13 is applied.","g":"/ncc/e1d4","a19":["E1.5"]},{"c":"E1D5","t":"Where sprinklers are required: all classifications","p":"Part E1 Fire fighting equipment","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e1-fire-fighting-equipment#E1D5","x":"Sprinklers are required throughout the whole building if any part of the building has an effective height of more than 25 m.\nExemptions\nE1D5 does not apply to—\na class 7a open-deck carpark that is a separate building; or\na Class 8 electricity network substation with a floor area not more than 200 m2 located within a multi-classified building.","g":"/ncc/e1d5","a19":["Table E1.5"]},{"c":"E1D6","t":"Where sprinklers are required: Class 2 and 3 buildings other than residential care buildings","p":"Part E1 Fire fighting equipment","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e1-fire-fighting-equipment#E1D6","x":"(1) In a Class 2 or 3 building, or any multi-classified building containing a Class 2 or 3 part, sprinklers are required throughout the whole building if any part of the building has—\na rise in storeys of 4 or more; and\nan effective height of not more than 25 m.\n(2) The requirements of (1) do not apply to—\na residential care building; and\na Class 8 electricity network substation with a floor area not more than 200 m2 located within a multi-classified building.","g":"/ncc/e1d6","a19":["Table E1.5"]},{"c":"E1D7","t":"Where sprinklers are required: Class 3 building used as a residential care building","p":"Part E1 Fire fighting equipment","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e1-fire-fighting-equipment#E1D7","x":"Sprinklers are required throughout—\na Class 3 building used as a residential care building; and\nany fire compartment containing a Class 3 part used for residential care.","g":"/ncc/e1d7","a19":["VIC Table E1.5","Table E1.5"]},{"c":"E1D8","t":"Where sprinklers are required: Class 6 building","p":"Part E1 Fire fighting equipment","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e1-fire-fighting-equipment#E1D8","x":"In a Class 6 building, sprinklers are required in fire compartments where either of the following apply:\nA floor area of more than 3 500 m2.\nA volume of more than 21 000 m3.","g":"/ncc/e1d8","a19":["Table E1.5"]},{"c":"E1D9","t":"Where sprinklers are required: Class 7a building","p":"Part E1 Fire fighting equipment","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e1-fire-fighting-equipment#E1D9","x":"In a Class 7a building, other than an open-deck carpark which is a separate building, sprinklers are required in fire compartments where—\nmore than 40 vehicles are accommodated; or\na carstacker is installed.\nNotes\nA carstacker is a machine that stores 2 or more cars in a vertical arrangement such that one or more cars may not be accessible from floor level.","g":"/ncc/e1d9","a19":["Table E1.5"]},{"c":"E1D10","t":"Where sprinklers are required: Class 9a health-care building used as a residential care building and Class 9c buildings","p":"Part E1 Fire fighting equipment","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e1-fire-fighting-equipment#E1D10","x":"(1) In a Class 9a health-care building used as a residential care building, sprinklers are required throughout the building and in any fire compartment containing a Class 9a part used for residential care.\n(2) In a Class 9c building, sprinklers are required throughout the building and in any fire compartment containing a Class 9c part.","g":"/ncc/e1d10","a19":["NT Table E1.5","Table E1.5"]},{"c":"E1D11","t":"Where sprinklers are required: Class 9b buildings","p":"Part E1 Fire fighting equipment","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e1-fire-fighting-equipment#E1D11","x":"(1) In a Class 9b building, other than an early childhood centre, see Part I1.\n(2) In a Class 9b early childhood centre and in a building containing a Class 9b early childhood centre, sprinklers are required throughout the whole building, including any part of another class.\nExemptions\nE1D11(2) does not apply to a Class 9b early childhood centre —\nwholly within a storey that provides direct egress to a road or open space; or\nwith a rise in storeys of not more than 2, where the Class 9b early childhood centre is the only use in the building.","g":"/ncc/e1d11","a19":["Table E1.5"]},{"c":"E1D12","t":"Where sprinklers are required: additional requirements","p":"Part E1 Fire fighting equipment","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e1-fire-fighting-equipment#E1D12","x":"(1) For sprinkler requirements for atriums, see Part G3.\n(2) For sprinkler requirements for large isolated buildings, see C3D4.","g":"/ncc/e1d12","a19":["Table E1.5"]},{"c":"E1D13","t":"Where sprinklers are required: occupancies of excessive hazard","p":"Part E1 Fire fighting equipment","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e1-fire-fighting-equipment#E1D13","x":"(1) In occupancies of excessive hazard, sprinklers are required in fire compartments where either of the following apply:\nA floor area of more than 2 000 m2.\nA volume of more than 12 000 m3.\n(2) For the purposes of (1), occupancies of excessive fire hazard comprise buildings which contain—\nhazardous processes or storage including the following:\nAircraft hangars.\nCane furnishing manufacture, processing and storage.\nFire-lighter and fireworks manufacture and warehousing.\nFoam plastic and foam plastic goods manufacture, processing and warehousing e.g. furniture factory.\nHydrocarbon based sheet product, manufacture, processing and warehousing e.g. vinyl floor coverings.\nWoodwool and other flammable loose fibrous material manufacture.\ncombustible goods with an aggregate volume exceeding 1000 m3 and stored to a height greater than 4 m including the following:\nAerosol packs with flammable contents.\nCarpets and clothing.\nElectrical appliances.\nCombustible compressed fibreboards (low and high density) and plywoods.\nCombustible cartons, irrespective of content.\nEsparto and other fibrous combustible material.\nFurniture including timber, cane and composite, where foamed rubber or plastics are incorporated.\nPaper storage (all forms of new or waste) e.g. bales, sheet, horizontal or vertical rolls, waxed coated or processed.\nTextiles raw and finished, e.g. rolled cloth, clothing and manchester.\nTimber storage including sheets, planks, boards, joists and cut sizes.\nVinyl, plastic, foamed plastic, rubber and other combustible sheets, offcuts and random pieces and rolled material storage, e.g. carpet, tar paper, linoleum, wood veneer and foam mattresses.\nAll materials having wrappings or preformed containers of foamed plastics.","g":"/ncc/e1d13","a19":["Table E1.5 (Note 4)"]},{"c":"E1D14","t":"Portable fire extinguishers","p":"Part E1 Fire fighting equipment","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e1-fire-fighting-equipment#E1D14","x":"(1) Portable fire extinguishers must be—\nprovided as listed in (3) and (4); and\nfor a Class 2, 3 or 5 building or Class 4 part of a building, provided—\nto serve the whole Class 2, 3 or 5 building or Class 4 part of a building where one or more internal fire hydrants are installed; or\nwhere internal fire hydrants are not installed, to serve any fire compartment with a floor area greater than 500 m2, and for the purposes of this clause, a sole-occupancy unit in a Class 2 or 3 building or Class 4 part of a building is considered to be a fire compartment; and\nsubject to (2), selected, located and distributed in accordance with Sections 1, 2, 3 and 4 of AS 2444.\n(2) Portable fire extinguishers provided in a Class 2 or 3 building or Class 4 part of a building must be—\nan ABE type fire extinguisher; and\na minimum size of 2.5 kg; and\ndistributed outside a sole-occupancy unit —\nto serve only the storey at which they are located; and\nso that the travel distance from the entrance doorway of any sole-occupancy unit to the nearest fire extinguisher is not more than 10 m.\n(3) In Class 2 to 9 buildings (except within sole-occupancy units of a Class 9c building), portable fire extinguishers must be provided as follows:\nTo cover Class AE or E fire risks associated with emergency services switchboards.\nTo cover Class F fire risks involving cooking oils and fats in kitchens.\nTo cover Class B fire risks in locations where flammable liquids in excess of 50 litres are stored or used (not including that held in fuel tanks of vehicles).\nTo cover Class A fire risks in normally occupied fire compartments less than 500 m2 not provided with fire hose reels (excluding open-deck carparks).\nTo cover Class A fire risks in classrooms and associated corridors in primary and secondary schools not provided with fire hose reels.\nTo cover Class A fire risks associated with a Class 2, 3 or 5 building or Class 4 part of a building.\n(4) In addition to the requirements of (3), portable fire extinguishers must be provided to cover Class A and E fire risks in the following occupancies in buildings, or parts of a building:\nA Class 9a health-care building, including a Class 9a building used as a residential care building.\nClass 3 parts of detention and correctional occupancies.\nClass 3 accommodation for children, aged persons and people with disabilities, including a Class 3 building used as a residential care building.\nA Class 9c building.\n(5) For the purposes of (3) and (4):\nFire risks are defined in accordance with AS 2444.\nAn emergency services switchboard is one which sustains emergency equipment operating in the emergency mode.\nAdditional extinguishers may be required to cover fire risks in relation to special hazards provided for in E1D17.\nThe fire risks in a Class 2 or 3 building or Class 4 part of a building must include risks within any sole-occupancy units, however portable fire extinguishers are not required to be located within a sole-occupancy unit unless the sole-occupancy unit has a floor area greater than 500 m2.\n(6) For the purposes of (4), where applicable, a Class E fire extinguisher need only be located at each nurses’ station, supervisors’ station or the like.","g":"/ncc/e1d14","a19":["E1.6 and Table E1.6"]},{"c":"E1D15","t":"Fire control centres","p":"Part E1 Fire fighting equipment","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e1-fire-fighting-equipment#E1D15","x":"A fire control centre facility in accordance with Specification 19 must be provided for—\na building with an effective height of more than 25 m; and\na Class 6, 7, 8 or 9 building with a total floor area of more than 18 000 m2.","g":"/ncc/e1d15","a19":["E1.8"]},{"c":"E1D16","t":"Fire precautions during construction","p":"Part E1 Fire fighting equipment","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e1-fire-fighting-equipment#E1D16","x":"In a building under construction—\nnot less than one fire extinguisher to suit Class A, B and C fires and electrical fires must be provided at all times on each storey adjacent to each required exit or temporary stairway or exit; and\nafter the building has reached an effective height of 12 m—\nthe required fire hydrants and fire hose reels must be operational in at least every storey that is covered by the roof or the floor structure above, except the 2 uppermost storeys; and\nany required booster connections must be installed.","g":"/ncc/e1d16","a19":["E1.9"]},{"c":"E1D17","t":"Provision for special hazards","p":"Part E1 Fire fighting equipment","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e1-fire-fighting-equipment#E1D17","x":"Suitable additional provision must be made if special problems of fighting fire could arise because of—\nthe nature or quantity of materials stored, displayed or used in a building or on the allotment; or\nthe location of the building in relation to a water supply for fire-fighting purposes.","g":"/ncc/e1d17","a19":["E1.10"]},{"c":"E2O1","t":"Objective","p":"Part E2 Smoke hazard management","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e2-smoke-hazard-management#E2O1","x":"The Objective of this Part is to—\nsafeguard occupants from illness or injury by warning them of a fire so that they may safely evacuate; and\nsafeguard occupants from illness or injury while evacuating during a fire.","g":"/ncc/e2o1","a19":["EO2"]},{"c":"E2F1","t":"Adequate safeguards","p":"Part E2 Smoke hazard management","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e2-smoke-hazard-management#E2F1","x":"A building is to be provided with safeguards so that—\noccupants are warned of a fire in the building so that they may safely evacuate; and\noccupants have time to safely evacuate before the environment in any evacuation route becomes untenable from the effects of fire.","g":"/ncc/e2f1"},{"c":"E2P1","t":"Automatic warning for sleeping occupants","p":"Part E2 Smoke hazard management","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e2-smoke-hazard-management#E2P1","x":"In a building providing sleeping accommodation, occupants must be provided with automatic warning on the detection of smoke so they may evacuate in the event of a fire to a safe place.\nApplications\nE2P1 only applies to a Class 2, 3, 9a or 9c building or Class 4 part of a building.","g":"/ncc/e2p1","a19":["EP2.1"]},{"c":"E2P2","t":"Safe evacuation routes","p":"Part E2 Smoke hazard management","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e2-smoke-hazard-management#E2P2","x":"(1) In the event of a fire in a building the conditions in any evacuation route must be maintained for the period of time occupants take to evacuate the part of the building so that—\nthe temperature will not endanger human life; and\nthe level of visibility will enable the evacuation route to be determined; and\nthe level of toxicity will not endanger human life.\n(2) The period of time occupants take to evacuate referred to in (1) must be appropriate to—\nthe number, mobility and other characteristics of the occupants; and\nthe function or use of the building; and\nthe travel distance and other characteristics of the building; and\nthe fire load; and\nthe potential fire intensity; and\nthe fire hazard; and\nany active fire safety systems installed in the building; and\nfire brigade intervention.\nLimitations\nE2P2 does not apply to an open-deck carpark or open spectator stand.","g":"/ncc/e2p2","a19":["EP2.2"]},{"c":"E2V1","t":"Fire Safety Verification Method","p":"Part E2 Smoke hazard management","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e2-smoke-hazard-management#E2V1","x":"Compliance with E2P1 and E2P2 is verified when a building is designed in accordance with C1V4.","g":"/ncc/e2v1","a19":["EV2.1"]},{"c":"E2D1","t":"Deemed-to-Satisfy Provisions","p":"Part E2 Smoke hazard management","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e2-smoke-hazard-management#E2D1","x":"(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements E2P1 and E2P2 are satisfied by complying with—\nE2D2 to E2D21; and\nin a building containing an atrium, Part G3; and\nin a building in an alpine area, Part G4; and\nfor additional requirements for Class 9b buildings, Part I1.\n(2) Where a Performance Solution is proposed, the relevant Performance Requirements must be determined in accordance with A2G2(3) and A2G4(3) as applicable.","g":"/ncc/e2d1","a19":["E2.0"]},{"c":"E2D2","t":"Application of part","p":"Part E2 Smoke hazard management","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e2-smoke-hazard-management#E2D2","x":"(1) The Deemed-to-Satisfy Provisions of this Part do not apply to—\nan open-deck carpark; or\nan open spectator stand; or\na Class 8 electricity network substation with a floor area not more than 200 m2, located within a multi-classified building.\n(2) In addition to the Deemed-to-Satisfy Provisions of E2D3 to E2D13, the following specific Deemed-to-Satisfy Provisions apply to the following Class 6 and Class 9b buildings:\nFor Class 6 buildings, in fire compartments more than 2000 m2—\nnot containing an enclosed common walkway or mall serving more than one Class 6 sole-occupancy unit — must comply with E2D14; or\ncontaining an enclosed common walkway or mall serving more than one Class 6 sole-occupancy unit — must comply with E2D15.\nFor Class 9b assembly buildings —\nnightclubs, discotheques and the like — must comply with E2D16; and\nexhibition halls — must comply with E2D17; and\ntheatres and public halls — must comply with E2D18; and\ntheatres and public halls (not covered by E2D18) including lecture theatres and cinema/auditorium complexes — must comply with E2D19; and\nother assembly buildings (not listed in (i) to (iv)) excluding schools — must comply with E2D20.\n(3) The smoke exhaust and smoke-and-heat vent provisions of this Part do not apply to any area not used by occupants for an extended period of time such as a storeroom with a floor area less than 30 m2, sanitary compartment, plant room or the like.","g":"/ncc/e2d2","a19":["E2.1"]},{"c":"E2D3","t":"General requirements","p":"Part E2 Smoke hazard management","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e2-smoke-hazard-management#E2D3","x":"(1) An air-handling system which does not form part of a smoke hazard management system in accordance with E2D4 to E2D20 and which recycles air from one fire compartment to another fire compartment or operates in a manner that may unduly contribute to the spread of smoke from one fire compartment to another fire compartment must, subject to (2), be designed and installed—\nto operate as a shutdown system in accordance with AS 1668.1; or\nsuch that it—\nincorporates smoke dampers complying with AS 1668.1 where the air-handling ducts penetrate any elements separating the fire compartments served; and\nis arranged such that the air-handling system is shut down and the smoke dampers are activated to close automatically by smoke detectors complying with clause 7.5 of AS 1670.1.\n(2) For the purposes of (1), each sole-occupancy unit in a Class 2 or 3 building is treated as a separate fire compartment.\n(3) Miscellaneous air-handling systems covered by Sections 5 and 6 of AS 1668.1 serving more than one fire compartment (other than a carpark ventilation system) and not forming part of a smoke hazard management system must comply with these Sections of the Standard.\n(4) A smoke detection system must be installed in accordance with S20C6 to operate AS 1668.1 systems that are provided for zone pressurisation and automatic air pressurisation for fire-isolated exits.","g":"/ncc/e2d3","a19":["E2.2"]},{"c":"E2D4","t":"Fire-isolated exits","p":"Part E2 Smoke hazard management","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e2-smoke-hazard-management#E2D4","x":"(1) A part of a building listed in (2) must be provided with—\nan automatic air pressurisation system for fire-isolated exits in accordance with AS 1668.1; or\nopen access ramps or balconies in accordance with D3D6.\n(2) The requirements of (1) apply to—\na required fire-isolated stairway, including any associated fire-isolated passageway or fire-isolated ramp serving—\nany storey above an effective height of 25 m; or\nmore than 2 below ground storeys, not counted in the rise in storeys in accordance with C2D3; or\nan atrium to which Part G3 applies; or\na Class 9a building with a rise in storeys of more than 2; or\na Class 9c building with a rise in storeys of more than 2; or\na Class 3 building used as a residential care building with a rise in storeys of more than 2; and\na required fire-isolated passageway or fire-isolated ramp with a length of travel more than 60 m to a road or open space.\n(3) An automatic air pressurisation system for a fire-isolated exit must serve the entire exit.\nNotes\nRefer to D2D12(4) for pressurisation of a fire-isolated exit having more than 2 access doorways from within the same storey.","g":"/ncc/e2d4","a19":["Table E2.2a"]},{"c":"E2D5","t":"Buildings more than 25 m in effective height: Class 2 and 3 buildings and Class 4 parts of a building","p":"Part E2 Smoke hazard management","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e2-smoke-hazard-management#E2D5","x":"An automatic smoke detection and alarm system complying with Specification 20 must be provided to the following:\nA Class 2 or 3 building which is more than 25 m in effective height.\nA Class 2 or 3 part of a building, or a Class 4 part of a building, in a building which is more than 25 m in effective height.\nNotes\nRefer to C3D15 for division of public corridors greater than 40 m in length.","g":"/ncc/e2d5","a19":["Table E2.2a"]},{"c":"E2D6","t":"Buildings more than 25 m in effective height: Class 5, 6, 7b, 8 and 9b buildings","p":"Part E2 Smoke hazard management","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e2-smoke-hazard-management#E2D6","x":"(1) A Class 5, 6, 7b, 8 or 9b building or part of a building must be provided with a zone pressurisation system between vertically separated fire compartments in accordance with AS 1668.1, if the building is more than 25 m in effective height.\n(2) The requirements of (1) do not apply to a building that has a fire compartment containing a Class 5, 6, 7b, 8 or 9b part (or a combination of these classes in the same fire compartment) where there is only one fire compartment containing these classifications in an otherwise Class 2, 3, 9a or 9c building.\n(3) For the purposes of (1), ‘vertically separated fire compartments ’ are fire compartments above and below each other, and not fire compartments within the same storey.\nNotes\nRefer to E2D14 to E2D20 for specific provisions applicable to a Class 6 (in a fire compartment having a floor area of more than 2000 m2) and Class 9b building or part of a building.","g":"/ncc/e2d6","a19":["Table E2.2a"]},{"c":"E2D7","t":"Buildings more than 25 m in effective height: Class 9a buildings","p":"Part E2 Smoke hazard management","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e2-smoke-hazard-management#E2D7","x":"(1) A Class 9a building must be provided with—\nan automatic smoke detection and alarm system complying with Specification 20; and\na zone pressurisation system between vertically separated fire compartments in accordance with AS 1668.1,\nif the building is more than 25 m in effective height.\n(2) For the purposes of (1), ‘vertically separated fire compartments ’ are fire compartments above and below each other, and not fire compartments within the same storey.\nNotes\nA building more than 25 m in effective height requires a sprinkler system under E1D4.","g":"/ncc/e2d7","a19":["Table E2.2a"]},{"c":"E2D8","t":"Buildings not more than 25 m in effective height: Class 2 and 3 buildings and Class 4 part of a building","p":"Part E2 Smoke hazard management","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e2-smoke-hazard-management#E2D8","x":"In a Class 2 and 3 building or part of a building, or Class 4 part of a building, if the building is not more than 25 m in effective height —\nit must be provided with an automatic smoke detection and alarm system complying with Specification 20; and\nwhere a required fire-isolated stairway serving the Class 2 or 3 parts also serves one or more storeys of Class 5, 6, 7 (other than an open-deck carpark), 8 or 9b parts—\nthe fire-isolated stairway, including any associated fire-isolated passageway or fire-isolated ramp, must be provided with an automatic air pressurisation system for fire-isolated exits in accordance with AS 1668.1; or\nthe Class 5, 6, 7 (other than an open-deck carpark), 8 and 9b parts must be provided with—\nan automatic smoke detection and alarm system complying with Specification 20; or\na sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17; and\nwhere a required fire-isolated stairway serving the Class 4 part also serves one or more storeys of Class 5, 6, 7 (other than an open-deck carpark), 8 or 9b parts—\na system complying with (b)(i) or (b)(ii) must be installed; or\na smoke alarm or detector system complying with Specification 20 must be provided except that alarms or detectors need only be installed adjacent to each doorway into each fire-isolated stairway (set back horizontally from the doorway by a distance of not more than 1.5 m) to initiate a building occupant warning system for the Class 4 part.\nNotes\nRefer to C3D15 for division of public corridors greater than 40 m in length.\nRefer to E2D14 to E2D20 for specific provisions applicable to a Class 6 (in a fire compartment having a floor area of more than 2000 m2) and Class 9b building or part of a building.","g":"/ncc/e2d8","a19":["Table E2.2a"]},{"c":"E2D9","t":"Buildings not more than 25 m in effective height: Class 5, 6, 7b, 8 and 9b buildings","p":"Part E2 Smoke hazard management","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e2-smoke-hazard-management#E2D9","x":"(1) A building not more than 25 m in effective height that—\nis a Class 5 or 9b school building or part of a building having a rise in storeys of more than 3; or\nis a Class 6, 7b, 8 or 9b building (other than a school) or part of a building having a rise in storeys of more than 2; or\nhas a rise in storeys of more than 2 and contains—\na Class 5 or 9b school part; and\na Class 6, 7b, 8 or 9b (other than a school) part,\nmust meet the requirements of (2).\n(2) A building referred to in (1) must be provided with—\nin each required fire-isolated stairway, including any associated fire-isolated passageway or fire-isolated ramp, an automatic air pressurisation system for fire-isolated exits in accordance with AS 1668.1; or\na zone pressurisation system between vertically separated fire compartments in accordance with AS 1668.1, if the building has more than one fire compartment; or\nan automatic smoke detection and alarm system complying with Specification 20; or\na sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17.\n(3) For the purposes of (2), vertically separated fire compartments are fire compartments above and below each other, and not fire compartments within the same storey.","g":"/ncc/e2d9","a19":["Table E2.2a"]},{"c":"E2D10","t":"Buildings not more than 25 m in effective height: large isolated buildings subject to C3D4","p":"Part E2 Smoke hazard management","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e2-smoke-hazard-management#E2D10","x":"(1) In a Class 7 or 8 building of not more than 25 m in effective height, and which does not exceed 18 000 m2 in floor area nor exceed 108 000 m3 in volume, the building must be provided with—\na sprinkler system complying with Specification 17, and provided with perimeter vehicular access complying with C3D5(2); or\nan automatic fire detection and alarm system complying with AS 1670.1 and monitored in accordance with S20C8; or\nan automatic smoke exhaust system in accordance with Specification 21; or\nautomatic smoke-and-heat vents in accordance with Specification 22; or\nnatural smoke venting, with ventilation openings distributed as evenly as practicable and comprising permanent openings at roof level with a free area not less than 1.5% of floor area and low level openings which may be permanent or readily openable with a free area not less than 1.5% of floor area.\n(2) In a Class 5, 6, 7, 8 or 9 building of not more than 25 m in effective height, and which exceeds 18 000 m2 in floor area or 108 000 m3 in volume, the building must be provided with—\nif the ceiling height of the fire compartment is not more than 12 m—\nan automatic smoke exhaust system in accordance with Specification 21; or\nautomatic smoke-and-heat vents in accordance with Specification 22; or\nif the ceiling height of the fire compartment is more than 12 m, an automatic smoke exhaust system in accordance with Specification 21.\n(3) For the purposes of (1) and (2), reference to ‘the building’ being provided with specified measures, means to the nominated classes within the building.\nNotes\nRefer to E2D14 to E2D20 for specific provisions applicable to a Class 6 (in a fire compartment having a floor area of more than 2000 m2) and Class 9b building or part of a building.\nRefer to E2D5 and E2D8 where a Class 5, 6, 7b, 8 and 9b building contains a Class 2, 3 or 4 part.","g":"/ncc/e2d10","a19":["NSW Table E2.2a","Table E2.2a"]},{"c":"E2D11","t":"Buildings not more than 25 m in effective height: Class 9a and 9c buildings","p":"Part E2 Smoke hazard management","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e2-smoke-hazard-management#E2D11","x":"(1) A Class 9a health-care building or a Class 9c building, or a building containing a part thereof, which is not more than 25 m in effective height, must be provided throughout with—\nan automatic smoke detection and alarm system complying with Specification 20; and\nautomatic shutdown of any air-handling system which does not form part of a zone pressurisation system (other than individual room units with a capacity not more than 1000 L/s, systems serving critical treatment areas and ventilation systems installed in accordance with Sections 5 and 6 of AS 1668.1) on the activation of—\nsmoke detectors installed in accordance with (a); and\nany other installed fire detection and alarm system including a sprinkler system complying with Specification 17; and\nin a building having a rise in storeys of more than 2 and not more than 25 m effective height (not being a Class 9c building)—\na zone pressurisation system between vertically separated fire compartments in accordance with AS 1668.1; or\na sprinkler system complying with Specification 17 throughout with residential sprinkler heads in patient care areas.\n(2) For the purposes of (1), ‘vertically separated fire compartments ’ are fire compartments above and below each other, and not fire compartments within the same storey.\nNotes\nRefer to S11C2 for the provisions for smoke dampers.","g":"/ncc/e2d11","a19":["Table E2.2a"]},{"c":"E2D12","t":"Class 7a buildings","p":"Part E2 Smoke hazard management","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e2-smoke-hazard-management#E2D12","x":"In a Class 7a building, including a basement, provided with a mechanical ventilation system in accordance with AS 1668.2, the carpark ventilation system must be designed and installed as a carpark ventilation system in accordance with AS 1668.1.","g":"/ncc/e2d12","a19":["Table E2.2a"]},{"c":"E2D13","t":"Basements (other than Class 7a buildings)","p":"Part E2 Smoke hazard management","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e2-smoke-hazard-management#E2D13","x":"(1) A basement, other than a Class 7a basement, not counted in the rise in storeys in accordance with C2D3, must—\ncomply with measures in accordance with this Part applicable to the building generally; and\nwhere the basement has a total floor area of more than 2000 m2, be provided with—\nif not more than 2 below ground storeys —\na zone pressurisation system between vertically separated fire compartments in accordance with AS 1668.1, if the basement has more than one fire compartment; or\nan automatic smoke detection and alarm system complying with Specification 20; or\na sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17; or\nif more than 2 below ground storeys, a sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17.\n(2) For the purposes of (1), ‘vertically separated fire compartments ’ are fire compartments above and below each other, and not fire compartments within the same storey.\nNotes\nRefer to E2D14 to E2D20 for specific provisions applicable to a Class 6 (in a fire compartment having a floor area of more than 2000 m2) and Class 9b building or part of a building.\nBasements with more than 3 below ground storeys or containing Class 6 or 9b occupancies with a large number of occupants may require special consideration in accordance with E2D21.","g":"/ncc/e2d13","a19":["Table E2.2a"]},{"c":"E2D14","t":"Class 6 buildings – in fire compartments more than 2000 m2: Class 6 building (not containing an enclosed common walkway or mall serving more than one Class 6 sole-occupancy unit)","p":"Part E2 Smoke hazard management","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e2-smoke-hazard-management#E2D14","x":"(1) This clause applies to a Class 6 building not containing an enclosed common walkway or mall serving more than one Class 6 sole-occupancy unit, except for—\na Class 6 sole-occupancy unit that—\nhas a floor area of not more than 2000 m2; and\nis single storey with a main public entrance opening to a road or open space; and\nis separated from other parts of the fire compartment by construction, including openings, penetrations and junctions with other building elements, that prevents the free passage of smoke; and\nparts of any other classification that are smoke separated from a Class 6 part by construction complying with (a)(iii).\n(2) Where the floor area of a Class 6 part of a fire compartment referred to in (1) is more than 2000 m2, the fire compartment must be provided with—\nan automatic smoke exhaust system complying with Specification 21; or\nif the building is single storey, automatic smoke-and-heat vents complying with Specification 22; or\nif the floor area of the fire compartment is not more than 3500 m2 and the building—\nis single storey, an automatic smoke detection and alarm system complying with Specification 20; or\nhas a rise in storeys of not more than 2, a sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17.","g":"/ncc/e2d14","a19":["Table E2.2b"]},{"c":"E2D15","t":"Class 6 buildings – in fire compartments more than 2000 m2: Class 6 building (containing an enclosed common walkway or mall serving more than one Class 6 sole-occupancy unit)","p":"Part E2 Smoke hazard management","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e2-smoke-hazard-management#E2D15","x":"(1) This clause applies to a Class 6 building containing an enclosed common walkway or mall serving more than one Class 6 sole-occupancy unit, except for—\na Class 6 sole-occupancy unit that—\nopens onto the enclosed common walkway or mall if the Class 6 sole-occupancy unit has a floor area of not more than 1000 m2; or\ndoes not open onto the enclosed common walkway or mall if the Class 6 sole-occupancy unit —\nhas a floor area of not more than 2000 m2; and\nis single storey with a main entrance opening to a road or open space; and\nis separated from other parts of the fire compartment by construction, including openings, penetrations and junctions with other building elements, that prevents the free passage of smoke; and\nparts of any other classification that are smoke separated from a Class 6 part by construction complying with (a)(ii)(C).\n(2) Where the floor area of a Class 6 part of a fire compartment referred to in (1) is more than 2000 m2, the fire compartment, including the enclosed common walkway or mall, must be provided with—\nan automatic smoke exhaust system complying with Specification 21; or\nif the building is single storey, automatic smoke-and-heat vents complying with Specification 22; or\nif the floor area of the fire compartment is not more than 3500 m2 and the building has a rise in storeys of not more than 2, a sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17.\nNotes\nA fire compartment having a floor area of more than 3500 m2 in a Class 6 building requires a sprinkler system under E1D4.","g":"/ncc/e2d15","a19":["Table E2.2b"]},{"c":"E2D16","t":"Class 9b – assembly buildings: nightclubs, discotheques and the like","p":"Part E2 Smoke hazard management","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e2-smoke-hazard-management#E2D16","x":"A Class 9b assembly building which is a nightclub, discotheque or the like must be provided with—\nautomatic shutdown of any air-handling system (other than miscellaneous exhaust air systems installed in accordance with Sections 5 and 6 of AS 1668.1) which does not form part of the smoke hazard management system, on the activation of—\nsmoke detectors installed complying with S20C6; and\nany other installed fire detection and alarm system, including a sprinkler system complying with Specification 17; and\nat least one of the following:\nAn automatic smoke exhaust system complying with Specification 21.\nIf the building is single storey, automatic smoke-and-heat vents complying with Specification 22.\nA sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17 with quick response sprinkler heads.","g":"/ncc/e2d16","a19":["NSW Table E2.2b","Table E2.2b"]},{"c":"E2D17","t":"Class 9b – assembly buildings: exhibition halls","p":"Part E2 Smoke hazard management","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e2-smoke-hazard-management#E2D17","x":"A Class 9b assembly building which is an exhibition hall must be provided with—\nautomatic shutdown of any air-handling system (other than miscellaneous exhaust air systems installed in accordance with Sections 5 and 6 of AS 1668.1) which does not form part of the smoke hazard management system, on the activation of—\nsmoke detectors installed complying with Specification 20; and\nany other installed fire detection and alarm system, including a sprinkler system complying with Specification 17; and\nwhere the floor area is more than 2000 m2 and not more than 3500 m2—\nan automatic smoke exhaust system complying with Specification 21; or\nif the building is single storey, automatic smoke-and-heat vents complying with Specification 22; or\na sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17; and\nwhere the floor area is more than 3500 m2, a sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17 and—\nan automatic smoke exhaust system complying with Specification 21; or\nautomatic smoke-and-heat vents complying with Specification 22, if the building is single storey.","g":"/ncc/e2d17","a19":["NSW Table E2.2b","Table E2.2b"]},{"c":"E2D18","t":"Class 9b – assembly buildings: theatres and public halls","p":"Part E2 Smoke hazard management","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e2-smoke-hazard-management#E2D18","x":"(1) This clause applies to a Class 9b assembly building where the building or part of the building is used as a theatre or public hall which—\nis a school assembly, church or community hall, and has a stage and any backstage area with a total floor area of more than 300 m2; or\nis not a school assembly, church or community hall, and has a stage and any backstage area with a total floor area of more than 200 m2; or\nhas a stage with an associated rigging loft.\n(2) A building or part of a building referred to in (1) must be provided with—\nan automatic smoke exhaust system complying with Specification 21; or\nif the building is single storey, automatic smoke-and-heat vents complying with Specification 22.","g":"/ncc/e2d18","a19":["NSW Table E2.2b","Table E2.2b"]},{"c":"E2D19","t":"Class 9b – assembly buildings: theatres and public halls (not listed in E2D18) including lecture theatres and cinema/auditorium complexes","p":"Part E2 Smoke hazard management","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e2-smoke-hazard-management#E2D19","x":"(1) This clause applies to a Class 9b assembly building where the building or part of the building is used as a theatre or public hall not listed in E2D18 and includes lecture theatres and cinema/auditorium complexes.\n(2) A building or part of a building referred to in (1)—\nmust be provided with automatic shutdown of any air-handling system (other than ventilation systems installed in accordance with Sections 5 and 6 of AS 1668.1) which does not form part of the smoke hazard management system, on the activation of—\nsmoke detectors installed complying with Specification 20; and\nany other installed fire detection and alarm system, including a sprinkler system complying with Specification 17; and\nother than in the case of a school lecture theatre, where the floor area of the Class 9b part of a fire compartment is more than 2000 m2, the Class 9b building or part must be provided with—\nan automatic smoke exhaust system complying with Specification 21; or\nif the building is single storey, automatic smoke-and-heat vents complying with Specification 22; or\nif the floor area of the fire compartment is not more than 5000 m2 and the building has a rise in storeys of not more than 2—\nan automatic smoke detection and alarm system complying with Specification 20; or\na sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17.","g":"/ncc/e2d19","a19":["NSW Table E2.2b","Table E2.2b"]},{"c":"E2D20","t":"Class 9b assembly buildings: other assembly buildings (not listed in E2D16 to E2D19)","p":"Part E2 Smoke hazard management","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e2-smoke-hazard-management#E2D20","x":"(1) The requirements of (2)—\napply to a Class 9b assembly building where the building or part of the building is used for a purpose other than—\nas described in E2D16 to E2D19; or\na school; and\ndo not apply to—\nsporting complexes (including sports halls, gymnasiums, swimming pools, ice and roller rinks, and the like) other than an indoor sports stadium with total spectator seating for more than 1000; or\nchurches and other places used solely for religious worship.\n(2) Each fire compartment, other than one in a building referred to in (1)(b), where the floor area of the Class 9b part is more than 2000 m2 must be provided with—\nan automatic smoke exhaust system complying with Specification 21; or\nif the building is single storey, automatic smoke-and-heat vents complying with Specification 22; or\nif the floor area of the fire compartment is not more than 5000 m2 and the building has a rise in storeys of not more than 2—\nan automatic smoke detection and alarm system complying with Specification 20; or\na sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17.\n(3) A building containing a Class 9b early childhood centre must be provided with an automatic smoke detection and alarm system complying with Specification 20 throughout the whole building, including any part of another class.","g":"/ncc/e2d20","a19":["Table E2.2b"]},{"c":"E2D21","t":"Provision for special hazards","p":"Part E2 Smoke hazard management","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e2-smoke-hazard-management#E2D21","x":"Additional smoke hazard management measures may be necessary due to the—\nspecial characteristics of the building; or\nspecial function or use of the building; or\nspecial type or quantity of materials stored, displayed or used in a building; or\nspecial mix of classifications within a building or fire compartment,\nwhich are not addressed in E2D4 to E2D20.","g":"/ncc/e2d21","a19":["E2.3"]},{"c":"E3O1","t":"Objective","p":"Part E3 Lift installations","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e3-lift-installations#E3O1","x":"The Objective of this Part is to—\nfacilitate the safe movement of occupants; and\nfacilitate access for emergency services personnel to carry out emergency procedures and assist in the evacuation of occupants.","g":"/ncc/e3o1","a19":["EO3"]},{"c":"E3F1","t":"Passenger lifts","p":"Part E3 Lift installations","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e3-lift-installations#E3F1","x":"Where a passenger lift is provided, it is to facilitate safe and easy—\nmovement for occupants with a disability; and\nevacuation of occupants, who due to illness or injury need stretcher assistance.","g":"/ncc/e3f1","a19":["EF3.1"]},{"c":"E3F2","t":"Emergency lifts","p":"Part E3 Lift installations","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e3-lift-installations#E3F2","x":"A building is to be provided with one or more passenger lifts to facilitate—\nthe safe access for emergency services personnel; and\nsafe and easy evacuation of occupants who due to illness, injury or disability cannot use stairways in the event of an emergency.\nApplications\nE3F2 only applies to—\na building with an effective height of more than 25 m; and\na Class 9a building in which patient care area are located above a level with direct access to a road or open space.","g":"/ncc/e3f2","a19":["EF3.2"]},{"c":"E3F3","t":"Emergency alerts","p":"Part E3 Lift installations","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e3-lift-installations#E3F3","x":"A building having a passenger lift is to be provided with measures to alert occupants about the use of the lift in an emergency.","g":"/ncc/e3f3","a19":["EF3.3"]},{"c":"E3P1","t":"Stretcher facilities","p":"Part E3 Lift installations","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e3-lift-installations#E3P1","x":"Stretcher facilities must be provided, to the degree necessary—\nin at least one emergency lift required by E3P2; or\nwhere an emergency lift is not required and a passenger lift is provided, in at least one lift, to serve each floor in the building served by the passenger lift.","g":"/ncc/e3p1","a19":["EP3.1"]},{"c":"E3P2","t":"Emergency lifts","p":"Part E3 Lift installations","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e3-lift-installations#E3P2","x":"One or more passenger lifts fitted as emergency lifts to serve each floor served by the lifts in a building must be installed to facilitate the activities of the fire brigade and other emergency services personnel.\nApplications\nE3P2 only applies to—\na building with an effective height of more than 25 m; and\na Class 9a building in which patient care areas are located at a level that does not have direct access to a road or open space.","g":"/ncc/e3p2","a19":["EP3.2"]},{"c":"E3P3","t":"Emergency alerts","p":"Part E3 Lift installations","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e3-lift-installations#E3P3","x":"Signs or other means must be provided to alert occupants about the use of a lift during an emergency.","g":"/ncc/e3p3","a19":["EP3.3"]},{"c":"E3P4","t":"Lift access for people with a disability","p":"Part E3 Lift installations","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e3-lift-installations#E3P4","x":"When a passenger lift is provided in a building required to be accessible, it must be suitable for use by people with a disability.","g":"/ncc/e3p4","a19":["EP3.4"]},{"c":"E3V1","t":"Fire Safety Verification Method","p":"Part E3 Lift installations","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e3-lift-installations#E3V1","x":"Compliance with E3P2 is verified when a building is designed in accordance with C1V4.","g":"/ncc/e3v1","a19":["EV3.1"]},{"c":"E3V2","t":"Emergency alerts on the use of lifts","p":"Part E3 Lift installations","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e3-lift-installations#E3V2","x":"(1) Compliance with E3P3 is verified when building occupants are provided with automatic warning that lifts must not be used during a fire emergency.\n(2) The automatic warning must—\nbe initiated by a smoke hazard management system complying with Part E2; and\nbe provided via a sound system complying with the relevant provisions of AS 1670.4; and\nhave a flashing warning sign installed in accordance with AS 1670.4 displaying the words “do not use lift”.","g":"/ncc/e3v2","a19":["EV3.2"]},{"c":"E3D1","t":"Deemed-to-Satisfy Provisions","p":"Part E3 Lift installations","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e3-lift-installations#E3D1","x":"(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements E3P1 to E3P4 are satisfied by complying with—\nE3D2 to E3D12; and\nfor a building containing an occupiable outdoor area, Part G6; and\nfor public transport buildings, Part I2.\n(2) Where a Performance Solution is proposed, the relevant Performance Requirements must be determined in accordance with A2G2(3) and A2G4(3) as applicable.","g":"/ncc/e3d1","a19":["E3.0"]},{"c":"E3D2","t":"Lift installations","p":"Part E3 Lift installations","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e3-lift-installations#E3D2","x":"An electric passenger lift installation and an electrohydraulic passenger lift installation must comply with Specification 24.","g":"/ncc/e3d2","a19":["E3.1"]},{"c":"E3D3","t":"Stretcher facility in lifts","p":"Part E3 Lift installations","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e3-lift-installations#E3D3","x":"(1) A stretcher facility in accordance with (2) must be provided—\nin at least one emergency lift required by E3D5; or\nwhere an emergency lift is not required, if passenger lifts are installed to serve any storey above an effective height of 12 m, in at least one of those lifts to serve each floor served by the lifts.\n(2) A stretcher facility must accommodate a raised stretcher with a patient lying on it horizontally by providing a clear space not less than 600 mm wide x 2000 mm long x 1400 mm high above the floor level.","g":"/ncc/e3d3","a19":["E3.2"]},{"c":"E3D4","t":"Warning against use of lifts in fire","p":"Part E3 Lift installations","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e3-lift-installations#E3D4","x":"(1) A warning sign must be displayed where it can be readily seen near every call button for a passenger lift or group of lifts throughout a building.\n(2) The requirements of (1) do not apply to a small lift such as a dumb-waiter or the like that is for the transport of goods only.\n(3) Each warning sign required by (1) must comply with the details and dimensions of Figure E3D4 and consist of—\nincised, inlaid or embossed letters in a colour contrasting with the background on a metal, wood, plastic or similar plate securely and permanently attached to the wall; or\nLetters in a colour contrasting with the background incised or inlaid directly into the surface of the material forming the wall.\nFigure E3D4 Warning sign for passenger lifts","g":"/ncc/e3d4","a19":["E3.3"]},{"c":"Table E3D5","t":"Minimum emergency lift dimensions in Class 9a buildings","p":"Part E3 Lift installations","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e3-lift-installations#_38344f64-7429-4baf-b124-353f5ffa2d32","x":"Lift component | Minimum dimension (mm)\nMinimum depth of car | 2280\nMinimum width of car | 1600\nMinimum floor to ceiling height | 2300\nMinimum door height | 2100\nMinimum door width | 1300","tb":"E3D5","g":"/ncc/table-e3d5"},{"c":"E3D5","t":"Emergency lifts","p":"Part E3 Lift installations","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e3-lift-installations#E3D5","x":"(1) At least one emergency lift complying with (5) must be installed in—\na building which has an effective height of more than 25 m; and\na Class 9a building in which patient care areas are located at a level that does not have direct egress to a road or open space.\n(2) An emergency lift may be combined with a passenger lift and must serve those storeys served by the passenger lift so that all storeys of the building served by passenger lifts are served by at least one emergency lift.\n(3) Where a storey is served by two or more passenger lifts, that storey must be served by at least two emergency lifts.\n(4) Where a storey is served by two or more lift shafts, the emergency lifts required by (3) must not be provided in the same shaft.\n(5) An emergency lift must—\nbe contained within a fire-resisting shaft in accordance with C3D11; and\nin a Class 9a building serving a patient care area —\nhave minimum dimensions, measured clear of all obstructions, including handrails, etc complying with Table E3D5; and\nbe connected to a standby power supply system where installed; and\nif the building has an effective height of more than 75 m, have a rating of at least—\n600 kg if not provided with a stretcher facility; or\n900 kg if provided with a stretcher facility.\nTable E3D5 Minimum emergency lift dimensions in Class 9a buildings\nLift component\nMinimum dimension (mm)\nMinimum depth of car\n2280\nMinimum width of car\n1600\nMinimum floor to ceiling height\n2300\nMinimum door height\n2100\nMinimum door width\n1300","g":"/ncc/e3d5","a19":["E3.4"]},{"c":"E3D6","t":"Landings","p":"Part E3 Lift installations","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e3-lift-installations#E3D6","x":"Access and egress to and from lift well landings must comply with Parts D2, D3 and D4.","g":"/ncc/e3d6","a19":["E3.5"]},{"c":"E3D7","t":"Passenger lift types and their limitations","p":"Part E3 Lift installations","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e3-lift-installations#E3D7","x":"(1) In an accessible building, every passenger lift must be one of the following lift types, subject to the limitations (if any) of each lift type:\nThere are no limitations on the use of electric passenger lifts, electrohydraulic passenger lifts or inclined lifts.\nStairway platform lifts must not—\nbe used to serve a space in a building accommodating more than 100 persons calculated according to D2D18; or\nbe used in a high traffic public use area such as a theatre, cinema, auditorium, transport interchange, shopping centre or the like; or\nbe used where it is possible to install another type of passenger lift; or\nconnect more than 2 storeys; or\nwhere more than 1 stairway lift is installed, serve more than 2 consecutive storeys; or\nwhen in the folded position, encroach on the minimum width of a stairway required by D2D8 to D2D11.\nA low-rise platform lift must not travel more than 1000 mm.\nA low-rise, low-speed constant pressure lift must not—\nfor an enclosed type, travel more than 4 m; or\nfor an unenclosed type, travel more than 2 m; or\nbe used in a high traffic public use areas in buildings such as a theatre, cinema, auditorium, transport interchange, shopping complex or the like.\n(2) A passenger lift referred to in (1) must not rely on a constant pressure device for its operation if the lift car is fully enclosed.","g":"/ncc/e3d7","a19":["E3.6","Table E3.6a","Table E3.6b"]},{"c":"E3D8","t":"Accessible features required for passenger lifts","p":"Part E3 Lift installations","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e3-lift-installations#E3D8","x":"In an accessible building, every passenger lift must have the following features where applicable:\nA handrail complying with the provisions for a mandatory handrail in AS 1735.12 for all lifts except—\na stairway platform lift; and\na low-rise platform lift.\nLift floor dimensions of not less than 1400 mm wide x 1600 mm deep for all lifts which travel more than 12 m.\nLift floor dimensions of not less than 1100 mm wide x 1400 mm deep for all lifts which travel not more than 12 m, except a stairway platform lift.\nLift floor dimensions of not less than 810 mm wide x 1200 mm deep for a stairway platform lift.\nMinimum clear door opening complying with AS 1735.12 for all lifts except a stairway platform lift.\nPassenger protection system complying with AS 1735.12 for all lifts with power-operated doors.\nLift landing doors at the upper landing for all lifts except a stairway platform lift.\nLift car and landing control buttons complying with AS 1735.12 for all lifts except—\na stairway platform lift; and\na low-rise platform lift.\nLighting in accordance with AS 1735.12 for all enclosed lift cars.\nFor all lifts serving more than 2 levels—\nautomatic audible information within the lift car to identify the level each time the car stops; and\naudible and visual indication at each lift landing to indicate the arrival of the lift car; and\naudible information and audible indication required by (i) and (ii) is to be provided in a range of between 20 - 80 dB(A) at a maximum frequency of 1500 Hz.\nEmergency hands-free communication, including a button that alerts a call centre of a problem and a light to signal that the call has been received, for all lifts except a stairway platform lift.","g":"/ncc/e3d8","a19":["Table E3.6a","Table E3.6b"]},{"c":"E3D9","t":"Fire service controls","p":"Part E3 Lift installations","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e3-lift-installations#E3D9","x":"Where lifts serve any storey above an effective height of 12 m, the following must be provided:\nA fire service recall control switch complying with E3D11 for—\na group of lifts; or\na single lift not in a group that serves the storey.\nA lift car fire service drive control switch complying with E3D12 for every lift.","g":"/ncc/e3d9","a19":["E3.7"]},{"c":"E3D10","t":"Residential care buildings","p":"Part E3 Lift installations","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e3-lift-installations#E3D10","x":"(1) Where residents in a Class 9c residential care building are on levels which do not have direct access to a road or open space, the building must be provided with either—\nat least one lift to accommodate a stretcher in accordance with E3D3(2); or\na ramp in accordance with AS 1428.1.\n(2) The lift or ramp required by (1) must discharge at a level providing direct access to a road or open space.","g":"/ncc/e3d10","a19":["E3.8"]},{"c":"E3D11","t":"Fire service recall control switch","p":"Part E3 Lift installations","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e3-lift-installations#E3D11","x":"(1) Each group of lifts must be provided with a single fire service recall control switch required by E3D9 that activates the fire service recall operation at (6).\n(2) The switch required by (1) must—\nbe located at the landing nominated by the appropriate authority; and\nbe labelled “FIRE SERVICE” in indelible white lettering on a red background; and\nhave two positions with an “OFF” and an “ON” position identified; and\nbe operable only by the use of a key that is removable in either the “OFF” position or the “ON” position.\n(3) Adhesive labels must not be used for compliance with (2)(b) and (c).\n(4) The key in (2)(d) must be able to turn all fire service recall control switches in the building and must have a different key combination to other keys used for lifts in the building.\n(5) The fire service recall operation must be activated by—\nswitching the fire service recall control switch in (1) to “ON”; or\na signal from a fire management system approved by the appropriate authority.\n(6) The activation of the fire service recall operation at (5) must—\ncancel all registered car and landing calls; and\ninactivate all door reopening devices that may be affected by smoke; and\nensure lift cars travelling toward the nominated floor continue to the nominated floor without stopping; and\nensure lift cars travelling away from the nominated floor stop at or before the next available floor without opening the doors (either automatically or by the door open button), reverse direction and travel without stopping to the nominated floor; and\nfor lifts stopped at a floor other than the nominated floor, close the doors and travel without stopping to the nominated floor; and\nensure that lifts stay at the nominated floor with doors open; and\npermit all lifts to return to normal service if the fire service recall control switch at (1) is switched to the “OFF” position during or after the fire service recall operation.\n(7) The requirements of (6) do not apply to lifts on inspection service or when the lift car fire service control switch required by E3D12 is in the \"ON\" position.\n(8) Lifts having manual controls must signal an alert to the lift for the lift to return to the nominated floor containing the recall switch that activated the signal.\n(9) A key required by (2)(d) must be stored within a secure enclosure in accordance with (10) located—\nif there is FDCIE, beside the FDCIE; or\nif there is no FDCIE—\nwithin the fire control centre; or\nadjacent to the fire service recall switch.\n(10) The secure enclosure in (9) must—\nbe securely attached to the wall; and\nbe openable using a device suitable for use by the fire brigade; and\nbe labelled “FIRE SERVICE LIFT KEYS” in capital letters not less than 20 mm in height and in a colour contrasting with the background.","g":"/ncc/e3d11","a19":["E3.9"]},{"c":"E3D12","t":"Lift car fire service drive control switch","p":"Part E3 Lift installations","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e3-lift-installations#E3D12","x":"(1) The lift car fire service drive control switch required by E3D9 must be activated from within the lift car.\n(2) The switch must—\nbe located between 600 mm and 1500 mm above the lift car floor; and\nbe labelled “FIRE SERVICE” by indelible white lettering on a red background; and\nhave two positions with an “OFF” and an “ON” position identified; and\noperate only by the use of a key that is removable in either the “OFF” position or the “ON” position.\n(3) Adhesive labels must not be used for compliance with (2)(b) or (c).\n(4) When the lift car fire service drive control switch at (1) is turned to the \"ON\" position, the lift must—\nnot respond to the fire service recall control switch; and\ncancel all registered lift car and landing calls; and\noverride all lift car call access control systems; and\ninactivate all door reopening devices that may be affected by smoke; and\nallow the registration of lift car call by lift car call buttons, however the lift doors must not close in response to the registration of lift car calls; and\nactivate door closing by constant pressure being applied on the “door close” button unless the button is released before the doors are fully closed, in which case the doors must reopen and any registered lift car calls must be cancelled; and\nwhen the doors are closed, move the lift in response to registered lift car calls while allowing additional lift car calls to also be registered; and\ntravel to the first possible floor in response to registered lift car calls and cancel all registered lift car calls after the lift stops; and\nensure doors do not open automatically, rather by constant pressure being applied on the “door open” button unless the button is released before the doors are fully open, in which case the doors must re-close.\n(5) The requirements of (4) do not apply to a lift operating on inspection service.\n(6) A multi-deck lift installation must have systems in place that—\nare able to communicate to the fire officer that the fire service drive control switch will not operate until all decks have been cleared of passengers; and\nensure there is an appropriate method of clearing all deck landings of passengers; and\nmaintain all doors to deck landings not containing the fire service control switch closed and inoperative while the lift is on fire service drive control.\n(7) A key required by (2)(d) must be stored in the enclosure required by E3D11(9).","g":"/ncc/e3d12","a19":["E3.10"]},{"c":"E4O1","t":"Objective","p":"Part E4 Visibility in an emergency, exit signs and warning systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e4-visibility-emergency-exit-signs-and-warning-systems#E4O1","x":"The Objective of this Part is, in an emergency, to safeguard occupants from injury by—\nhaving adequate visibility; and\nhaving adequate identification of exits and paths of travel to exits; and\nbeing made aware of the emergency.","g":"/ncc/e4o1","a19":["EO4"]},{"c":"E4F1","t":"Visibility in an emergency, exit signs and warning systems","p":"Part E4 Visibility in an emergency, exit signs and warning systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e4-visibility-emergency-exit-signs-and-warning-systems#E4F1","x":"A building is to be provided with—\nadequate visibility upon failure of normal artificial lighting during an emergency; and\nadequate means—\nof warning occupants to evacuate; and\nto manage the evacuation process; and\nto identify exits and paths of travel to an exit.","g":"/ncc/e4f1","a19":["EF4.1"]},{"c":"E4P1","t":"Visibility in an emergency","p":"Part E4 Visibility in an emergency, exit signs and warning systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e4-visibility-emergency-exit-signs-and-warning-systems#E4P1","x":"To facilitate safe evacuation in an emergency, a building must be provided with a system that—\nensures a level of visibility sufficient to enable exits, paths of travel to exits and any obstacles along a path of travel to an exit to be identified; and\nactivates instantaneously upon the failure of an artificial lighting system, to the degree necessary, appropriate to—\nthe function or use of the building; and\nthe floor area of the building; and\nthe distance of travel to an exit.\nLimitations\nE4P1 does not apply to the internal parts of a sole-occupancy unit in a Class 2, 3 or 9c building or Class 4 part of a building.","g":"/ncc/e4p1","a19":["EP4.1"]},{"c":"E4P2","t":"Identification of exits","p":"Part E4 Visibility in an emergency, exit signs and warning systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e4-visibility-emergency-exit-signs-and-warning-systems#E4P2","x":"To facilitate evacuation, suitable signs or other means of identification must, to the degree necessary—\nbe provided to identify the location of exits; and\nguide occupants to exits; and\nbe clearly visible to occupants; and\noperate in the event of a power failure of the main lighting system for sufficient time for occupants to safely evacuate.\nLimitations\nE4P2 does not apply to the internal parts of a sole-occupancy unit in a Class 2 or 3 or Class 4 part of a building.","g":"/ncc/e4p2","a19":["EP4.2"]},{"c":"E4P3","t":"Emergency warning and intercom systems","p":"Part E4 Visibility in an emergency, exit signs and warning systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e4-visibility-emergency-exit-signs-and-warning-systems#E4P3","x":"To warn occupants of an emergency and assist evacuation of a building, an emergency warning and intercom system must be provided, to the degree necessary, appropriate to—\nthe floor area of the building; and\nthe function or use of the building; and\nthe height of the building.","g":"/ncc/e4p3","a19":["EP4.3"]},{"c":"E4V1","t":"Emergency lighting","p":"Part E4 Visibility in an emergency, exit signs and warning systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e4-visibility-emergency-exit-signs-and-warning-systems#E4V1","x":"(1) Compliance with E4P1 is verified for the level of visibility for safe evacuation in an emergency and instantaneous activation, when an emergency lighting system satisfies the requirements of (2) to (5).\n(2) The calculated horizontal illuminance is not less than—\n0.2 lux at floor level in the path of travel to an exit; and\n1 lux at each floor level or tread in every required —\nfire-isolated stairway; or\nfire-isolated passageway; or\nfire-isolated ramp; or\nnon-fire-isolated stairway; or\nnon-fire-isolated ramp.\n(3) The emergency lighting provides a level of illuminance not less than—\n10% of that required by (2) within 1 second of energisation; and\n80% of that required by (2) within 15 seconds of energisation.\n(4) The full level of illumination required by (2) must be achieved within 60 seconds of energisation.\n(5) An emergency lighting system must operate at not less than the minimum required level of illuminance for not less than 90 minutes.","g":"/ncc/e4v1","a19":["EV4.1"]},{"c":"E4V2","t":"Fire Safety Verification Method","p":"Part E4 Visibility in an emergency, exit signs and warning systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e4-visibility-emergency-exit-signs-and-warning-systems#E4V2","x":"Compliance with E4P1, E4P2 and E4P3 is verified when a building is designed in accordance with C1V4.","g":"/ncc/e4v2","a19":["EV4.2"]},{"c":"E4D1","t":"Deemed-to-Satisfy Provisions","p":"Part E4 Visibility in an emergency, exit signs and warning systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e4-visibility-emergency-exit-signs-and-warning-systems#E4D1","x":"(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements E4P1 to E4P3 are satisfied by complying with—\nE4D2 to E4D9; and\nin a building containing an atrium, Part G3; and\nin a building in an alpine area, Part G4; and\nfor a building containing an occupiable outdoor area, Part G6; and\nfor additional requirements for Class 9b buildings, Part I1; and\nfor farm buildings and farm sheds, Part I3.\n(2) Where a Performance Solution is proposed, the relevant Performance Requirements must be determined in accordance with A2G2(3) and A2G4(3) as applicable.","g":"/ncc/e4d1","a19":["E4.0"]},{"c":"E4D2","t":"Emergency lighting requirements","p":"Part E4 Visibility in an emergency, exit signs and warning systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e4-visibility-emergency-exit-signs-and-warning-systems#E4D2","x":"An emergency lighting system must be installed—\nin every fire-isolated stairway, fire-isolated passageway or fire-isolated ramp; and\nin every storey of a Class 5, 6, 7, 8 or 9 building where the storey has an area more than 300 m2—\nin every passageway, corridor, hallway, or the like, that is part of the path of travel to an exit; and\nin any room having a floor area more than 100 m2 that does not open to a corridor or space that has emergency lighting or to a road or open space; and\nin any room having a floor area more than 300 m2; and\nin every passageway, corridor, hallway, or the like, having a length of more than 6 m from the entrance doorway of any sole-occupancy unit in a Class 2 or 3 building or Class 4 part of a building to the nearest doorway opening directly to—\na fire-isolated stairway, fire-isolated passageway or fire-isolated ramp; or\nan external stairway serving instead of a fire-isolated stairway under D2D13; or\nan external balcony leading to a fire-isolated stairway, fire-isolated passageway or fire-isolated ramp; or\na road or open space; and\nin every required non-fire-isolated stairway; and\nin a sole-occupancy unit in a Class 5, 6 or 9 building if—\nthe floor area of the unit is more than 300 m2; and\nan exit from the unit does not open to a road or open space or to an external stairway, passageway, balcony or ramp, leading directly to a road or open space; and\nin every room or space to which there is public access in every storey in a Class 6 or 9b building if—\nthe floor area in that storey is more than 300 m2; or\nany point on the floor of that storey is more than 20 m from the nearest doorway leading directly to a stairway, ramp, passageway, road or open space; or\negress from that storey involves a vertical rise within the building of more than 1.5 m, or any vertical rise if the storey concerned does not admit sufficient light; or\nthe storey provides a path of travel from any other storey required by (i), (ii) or (iii) to have emergency lighting; and\nin a Class 9a health-care building —\nin every passageway, corridor, hallway, or the like, serving a treatment area or a ward area; and\nin every room having a floor area of more than 120 m2 in a patient care area; and\nin every Class 9c building excluding within sole-occupancy units; and\nin every required fire control centre.","g":"/ncc/e4d2","a19":["SA E4.2(b)(iii)","(j)","E4.2"]},{"c":"E4D3","t":"Measurement of distance","p":"Part E4 Visibility in an emergency, exit signs and warning systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e4-visibility-emergency-exit-signs-and-warning-systems#E4D3","x":"Distances, other than vertical rise, must be measured along the shortest path of travel whether by straight lines, curves or a combination of both.","g":"/ncc/e4d3","a19":["E4.3"]},{"c":"E4D4","t":"Design and operation of emergency lighting","p":"Part E4 Visibility in an emergency, exit signs and warning systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e4-visibility-emergency-exit-signs-and-warning-systems#E4D4","x":"Every required emergency lighting system must comply with AS/NZS 2293.1.","g":"/ncc/e4d4","a19":["E4.4"]},{"c":"E4D5","t":"Exit signs","p":"Part E4 Visibility in an emergency, exit signs and warning systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e4-visibility-emergency-exit-signs-and-warning-systems#E4D5","x":"An exit sign must be clearly visible to persons approaching the exit, and must be installed on, above or adjacent to each—\ndoor providing direct egress from a storey to—\nan enclosed stairway, passageway or ramp serving as a required exit; and\nan external stairway, passageway or ramp serving as a required exit; and\nan external access balcony leading to a required exit; and\ndoor from an enclosed stairway, passageway or ramp at every level of discharge to a road or open space; and\nhorizontal exit; and\ndoor serving as, or forming part of, a required exit in a storey required to be provided with emergency lighting in accordance with E4D2.","g":"/ncc/e4d5","a19":["SA E4.5(e)","E4.5"]},{"c":"E4D6","t":"Direction signs","p":"Part E4 Visibility in an emergency, exit signs and warning systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e4-visibility-emergency-exit-signs-and-warning-systems#E4D6","x":"If an exit is not readily apparent to persons occupying or visiting the building then exit signs must be installed in appropriate positions in corridors, hallways, lobbies, and the like, indicating the direction to a required exit.","g":"/ncc/e4d6","a19":["NSW E4.6","E4.6"]},{"c":"E4D7","t":"Class 2 and 3 buildings and Class 4 parts: exemptions","p":"Part E4 Visibility in an emergency, exit signs and warning systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e4-visibility-emergency-exit-signs-and-warning-systems#E4D7","x":"E4D5 does not apply to—\na Class 2 building in which every door referred to is clearly and legibly labelled on the side remote from the exit or balcony—\nwith the word “EXIT” in capital letters 25 mm high in a colour contrasting with that of the background; or\nby some other suitable method; and\nan entrance door of a sole-occupancy unit in a Class 2 or 3 building or Class 4 part of a building.","g":"/ncc/e4d7","a19":["E4.7"]},{"c":"E4D8","t":"Design and operation of exit signs","p":"Part E4 Visibility in an emergency, exit signs and warning systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e4-visibility-emergency-exit-signs-and-warning-systems#E4D8","x":"Every required exit sign must—\ncomply with—\nAS/NZS 2293.1; or\nfor a passive photoluminescent exit sign, Specification 25; or\nfor a hybrid photoluminescent exit sign, SA TS 5367; and\nbe clearly visible at all times when the building is occupied by any person having the right of legal entry to the building.","g":"/ncc/e4d8","a19":["SA E4.8(c)","E4.8"]},{"c":"E4D9","t":"Emergency warning and intercom systems","p":"Part E4 Visibility in an emergency, exit signs and warning systems","u":"/editions/ncc-2025/adopted/volume-one/e-services-and-equipment/part-e4-visibility-emergency-exit-signs-and-warning-systems#E4D9","x":"An emergency warning and intercom system complying, where applicable, with AS 1670.4 must be installed—\nin a building with an effective height of more than 25 m; and\nin a Class 3 building having a rise in storeys of more than 2 and used as—\nthe residential part of a primary or secondary school; or\naccommodation for the aged, children or people with a disability; and\nin a Class 3 building used as a residential care building, except that the system—\nmust be arranged to provide a warning for occupants; and\nin areas used by the residents, may have its alarm adjusted in volume and content to minimise trauma consistent with the type and condition of residents; and\nin a Class 9a building having a floor area of more than 1000 m2 or a rise in storeys of more than 2, and the system—\nmust be arranged to provide a warning for occupants; and\nin a ward area, may have its alarm adjusted in volume and content to minimise trauma consistent with the type and condition of patients; and\nin a Class 9b building—\nused as a school and having a rise in storeys of more than 3; or\nused as a theatre, public hall, or the like, having a floor area more than 1000 m2 or a rise in storeys of more than 2.","g":"/ncc/e4d9","a19":["E4.9"]},{"c":"S26C1","t":"Scope","p":"Specification 26 Waterproofing and water-resistance requirements for building elements in wet areas","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/26-waterproofing-and-water-resistance-requirements-building-elements-wet-areas#S26C1","x":"This Specification sets out requirements for building elements in wet areas that are required to be—\nwater resistant; or\nwaterproof.","g":"/ncc/s26c1","a19":["Table F1.7"]},{"c":"S26C2","t":"Application","p":"Specification 26 Waterproofing and water-resistance requirements for building elements in wet areas","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/26-waterproofing-and-water-resistance-requirements-building-elements-wet-areas#S26C2","x":"(1) The requirements of this Specification apply to—\nshower areas (enclosed and unenclosed); and\nareas outside a shower area; and\nareas adjacent to baths and spas; and\nother areas as set out in clause S26C6.\n(2) Where a shower is above a bath or spa, use requirements for a shower.","g":"/ncc/s26c2","a19":["Table F1.7"]},{"c":"S26C3","t":"Shower area (enclosed and unenclosed)","p":"Specification 26 Waterproofing and water-resistance requirements for building elements in wet areas","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/26-waterproofing-and-water-resistance-requirements-building-elements-wet-areas#S26C3","x":"(1) For a shower area with a hob, step-down or level threshold, the following applies:\nThe floor of the shower area must be waterproof, including any hob or step-down; and\nThe walls of the shower area must be waterproof not less than 1800 mm above the floor substrate.\nWall junctions and joints within the shower area must be waterproof.\nWall/floor junctions within the shower area must be waterproof.\nPenetrations within the shower area must be waterproof.\n(2) A shower with a preformed shower base must also comply with the requirements of (1), except for (a) which is not applicable.","g":"/ncc/s26c3","a19":["Table F1.7"]},{"c":"S26C4","t":"Area outside shower area","p":"Specification 26 Waterproofing and water-resistance requirements for building elements in wet areas","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/26-waterproofing-and-water-resistance-requirements-building-elements-wet-areas#S26C4","x":"(1) For concrete, compressed fibre-cement and fibre-cement sheet flooring, the floor of the room must be water resistant.\n(2) For timber floors including particleboard, plywood and other timber based flooring materials, the floor of the room must be waterproof.\n(3) Wall/floor junctions must be waterproof.","g":"/ncc/s26c4","a19":["Table F1.7"]},{"c":"S26C5","t":"Areas adjacent to baths and spas without showers","p":"Specification 26 Waterproofing and water-resistance requirements for building elements in wet areas","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/26-waterproofing-and-water-resistance-requirements-building-elements-wet-areas#S26C5","x":"(1) For areas adjacent to a bath and spa, the following applies:\nFor concrete, compressed fibre-cement and fibre-cement sheet flooring, the floor of the room must be water resistant.\nFor timber floors including particleboard, plywood and other timber based flooring materials, the floor of the room must be waterproof.\nTap and spout penetrations must be waterproof where they occur in horizontal surfaces.\n(2) For areas adjacent to a non-freestanding bath and spa, the following applies:\nWalls must be water resistant —\nto a height of not less than 150 mm above the vessel, for the extent of the vessel, where the vessel is within 75 mm of a wall; and\nat all exposed surfaces below vessel lip.\nWall junctions and joints must be water resistant within 150 mm above a vessel for the extent of the vessel.\nWall/floor junctions must be waterproof for the extent of the vessel.\n(3) For inserted baths and spas, the following applies:\nFor floors and horizontal surfaces:\nAny shelf area adjoining the bath or spa must be waterproof and include a waterstop under the vessel lip.\nThere are no requirements for the floor under a bath or spa.\nFor walls:\nWaterproof to not less than 150 mm above the lip of a bath or spa.\nThere are no requirements for walls beneath the lip of a bath or spa.\nFor wall junctions and joints:\nWaterproof junctions within 150 mm of a bath or spa.\nThere are no requirements for junctions and joints in walls beneath the lip of a bath or spa.\nTap and spout penetrations must be waterproof where they occur in horizontal surfaces.","g":"/ncc/s26c5","a19":["Table F1.7"]},{"c":"S26C6","t":"Other areas","p":"Specification 26 Waterproofing and water-resistance requirements for building elements in wet areas","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/26-waterproofing-and-water-resistance-requirements-building-elements-wet-areas#S26C6","x":"(1) For walls adjoining other types of vessels (e.g. sink, basin or laundry tub), the following applies:\nWalls must be water resistant to a height of not less than 150 mm above the vessel, for the extent of the vessel, where the vessel is within 75 mm of a wall.\nWaterproof wall junctions where a vessel is fixed to a wall.\nWaterproof tap and spout penetrations where they occur in surfaces required to be waterproof or water resistant.\n(2) For laundries and WCs, other than WCs as described in (3), the following applies:\nWater resistant floor of the room.\nWater resistant wall/floor junctions.\nWaterproof penetrations where they occur in surfaces required to be waterproof.\n(3) For WCs with a handheld bidet spray installation, the following applies:\nWaterproof floor of the room.\nWalls must be—\nwaterproof within a 1500 mm radius from the wall connection of the handheld bidet spray device to a height of not less than 150 mm above the floor substrate; and\nwater resistant within a 1500 mm radius from the wall connection of the handheld bidet spray device to a height of not less than 1200 mm above the finished floor level of the WC.\nWaterproof wall junctions within the WC area within 1500 mm radius from the wall connection of the handheld bidet spray device.\nWaterproof wall/floor junctions within the WC area within 1500 mm radius from the wall connection of the handheld bidet spray device.\nWaterproof penetrations in WC area.\n(4) For bathrooms and laundries required to be provided with a floor waste by F2D4, the following applies:\nWaterproof floor of the room.\nWaterproof wall/floor junctions.\nWaterproof penetrations where they occur through the floor.","g":"/ncc/s26c6","a19":["Table F1.7"]},{"c":"S27C1","t":"Scope","p":"Specification 27 Accessible adult change facilities","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/27-accessible-adult-change-facilities#S27C1","x":"This Specification contains the requirements for accessible adult change facilities.","g":"/ncc/s27c1","a19":["Spec F2.9: 1"]},{"c":"S27C2","t":"General requirements","p":"Specification 27 Accessible adult change facilities","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/27-accessible-adult-change-facilities#S27C2","x":"(1) Each accessible adult change facility must—\nbe constructed so that all required equipment and fixtures are contained within the same room; and\nif it is a unisex facility, be located such that it can be entered without crossing an area reserved for one sex only.\n(2) In each accessible adult change facility, the following must be provided:\nA hoist complying with S27C3.\nA toilet pan, seat, backrest and grabrails complying with S27C4.\nA washbasin and tap complying with S27C5.\nFixtures and fittings as specified in S27C6.\nA change table complying with S27C7.\nChanging rails complying with S27C8.\nAn automated sliding entrance door complying with S27C9.\nSignage complying with S27C10.\nOperating instructions for the hoist and change table in accordance with S27C11.\nCirculation spaces complying with Figures S27C2a, S27C2b and S27C2c.\n(3) The floor surface must have a slip resistance classification of not less than R10 or P3 when tested in accordance with AS 4586.\n(4) For the purposes of Figures S27C2a, S27C2b and S27C2c, the following applies:\nThe Roman numerals shown in Figures S27C2a, S27C2b and S27C2c indicate the following required circulation spaces:\nTurning space: a full circle of 1125 mm radius.\nEach side of the pan: 900 mm (measured from each edge of the pan).\nIn front of the pan: 2350 mm (measured from the wall behind the pan, and therefore includes the pan itself).\nFor a washbasin: the width of the basin (450 mm) increasing to a width of 1350 mm measured at a distance of 750 mm out from the wall against which the washbasin is mounted then continuing at that width for a further 800 mm (to a total of 1550 mm out from the wall).\nFor changing rails: the width of the rails increasing to a width of 1350 mm at a distance of 750 mm out from the wall to which the rails are fixed then continuing at that width for a further 800 mm (to a total of 1550 mm out from the wall).\nAll required circulation spaces must extend for a minimum height of 2000 mm above finished floor level.\nRequired circulation spaces may be overlapped.\nFigure S27C2a Required circulation spaces — Turning space, each side of the pan and in front of the pan\nFigure S27C2b Required circulation spaces — Turning space and circulation space for a washbasin\nFigure S27C2c Required circulation spaces — Turning space and circulation space for changing rails","g":"/ncc/s27c2","a19":["Spec F2.9: 2"]},{"c":"S27C3","t":"Hoist","p":"Specification 27 Accessible adult change facilities","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/27-accessible-adult-change-facilities#S27C3","x":"The hoist must—\nprovide a constant charge in-line room coverage hoist system (also known as an “XY” system or gantry) including 2 parallel fixed rails and a moving traverse rail; and\nprovide coverage over the entire room; and\nhave a maximum safe working load of not less than 180 kg; and\nbe capable of sustaining a static load of not less than 1.5 times the rated load; and\nhave a minimum lifting height of 2100 mm.","g":"/ncc/s27c3","a19":["Spec F2.9: 3"]},{"c":"S27C4","t":"Toilet pan, seat, backrest and grabrails","p":"Specification 27 Accessible adult change facilities","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/27-accessible-adult-change-facilities#S27C4","x":"(1) The toilet pan must be of the centrally located (\"peninsula-type\") design.\n(2) The toilet pan must be installed so that—\nthe front edge of the pan is 800 mm (±10 mm) from the rear wall; and\nthe top of the seat is between 460 mm and 480 mm above finished floor level; and\nthere is a minimum clearance of 900 mm, measured horizontally, between each side of the pan and any adjacent wall or privacy screen.\n(3) The toilet seat must—\nbe of the full-round type (not open-fronted) with minimal contours to the top surface; and\nbe securely fixed in position when in use; and\nhave seat fixings that provide lateral stability to the seat when the seat is in use; and\nbe load-rated to 150 kg; and\nhave a minimum luminance contrast of 30% against the pan, wall or floor; and\nremain in the fully upright position when raised.\n(4) A hand-operated flushing control must—\nbe located on the centreline of the toilet, at a height above finished floor level of—\nnot less than 600 mm; and\nnot more than 1100 mm; and\nnot be located within the area required for any grabrails or backrest; and\nhave the button mounted so that it is proud of the wall surface, and activates the flushing operation before the button becomes level with the surrounding surface.\n(5) An automatically activated flushing system need not comply with the requirements of (4).\n(6) The backrest must—\nbe capable of withstanding a force, in any direction, of not less than 1100 N; and\nhave a minimum height, between the lower edge of the backrest and the top of the seat, of between 120 mm and 150 mm; and\nhave a vertical height, between the upper and lower edges of the backrest, of between 150 mm and 200 mm; and\nhave a width of between 350 mm and 400 mm; and\nbe positioned such that the face of the backrest achieves an angle of between 95° and 100° back from the seat, when the seat is in use.\n(7) Grabrails must be installed adjacent to each side of the pan and must be—\nof the drop-down type; and\nlocated such that—\nthe top of each rail is between 800 mm and 810 mm above finished floor level; and\nthe rails are between 750 mm and 770 mm apart, measured centre-to-centre, and equidistant to the centreline of the pan; and\nat least 850 mm long; and\nwith a diameter of between 30 mm and 40 mm; and\nsecurely fixed to withstand a force, in any direction, of not less than 1100 N; and\nprovided with a toilet paper dispenser on one side; and\ncapable of being lifted up or swung away when not in use, so as to allow unimpeded access to the toilet pan.","g":"/ncc/s27c4","a19":["Spec F2.9: 4"]},{"c":"S27C5","t":"Washbasin and tap","p":"Specification 27 Accessible adult change facilities","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/27-accessible-adult-change-facilities#S27C5","x":"(1) The washbasin must be installed so that the rim of the basin is between 800 mm and 830 mm above finished floor level.\n(2) Exposed heated water supply pipes must be insulated or located so as not to pose a hazard.\n(3) Water supply or sanitary drainage pipes must not encroach on the space under the basin.\n(4) The washbasin must have an integrated shelf not less than 300 mm long.\n(5) Water taps must have a single lever flick-mixer handle or a sensor plate or the like.\n(6) Where lever handles are provided, they must be installed with a clear space of not less than 50 mm between the tap and any adjacent surface.\n(7) Heated water must be provided and temperature controlled in accordance with Part B2 of NCC Volume Three.","g":"/ncc/s27c5","a19":["Spec F2.9: 5"]},{"c":"S27C6","t":"Fixtures and fittings","p":"Specification 27 Accessible adult change facilities","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/27-accessible-adult-change-facilities#S27C6","x":"(1) A vertical mirror must be provided at the washbasin, with a reflective surface that—\nis not less than 600 mm wide; and\nhas its bottom edge not more than 900 mm above finished floor level; and\nhas its top edge not less than 1850 mm above finished floor level.\n(2) If a second vertical mirror is provided in the facility, it must have a reflective surface that—\nis not less than 600 mm wide; and\nhas its bottom edge not less than 600 mm above finished floor level; and\nhas its top edge not less than 1850 mm above finished floor level.\n(3) Towel dispensers, hand dryers, soap dispensers and the like must be operable using one hand, and must be installed with their output or operative components—\nbetween 900 mm and 1100 mm above finished floor level; and\nnot less than 500 mm from any internal corner.\n(4) A soap dispenser must be installed above the integrated shelf required by S27C5(4).\n(5) A clothing hook must be installed so that it is located—\nat a height of between 1200 mm and 1350 mm above finished floor level; and\nadjacent to the washbasin; and\nnot less than 500 mm from any internal corner.\n(6) A sling hook with a minimum projection of 50 mm from the wall must be installed beside the change table at a height of 1500 mm above finished floor level.\n(7) Disposal bins must be provided as follows:\nA sanitary disposal bin in the corner adjacent to the toilet pan.\nAn incontinence pad disposal bin in the corner adjacent to the change table.","g":"/ncc/s27c6","a19":["Spec F2.9: 6"]},{"c":"S27C7","t":"Change table","p":"Specification 27 Accessible adult change facilities","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/27-accessible-adult-change-facilities#S27C7","x":"(1) The change table must be—\npermanently installed, with one of the long edges up against a wall and with a retractable safety rail on the opposite side; and\nmotorised for the purposes of height adjustment; and\nheight adjustable between 450 mm and 900 mm above finished floor level; and\nnot less than 700 mm wide; and\nnot less than 1800 mm long.\n(2) The change table must have a maximum safe working load of not less than 180 kg, including when raising or lowering the table.\n(3) The change table must not encroach on any required circulation space.\n(4) A dispenser for sanitary wipes must be provided.\n(5) A shelf not less than 400 mm long and 150 mm wide must be provided.","g":"/ncc/s27c7","a19":["Spec F2.9: 7"]},{"c":"S27C8","t":"Changing rails","p":"Specification 27 Accessible adult change facilities","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/27-accessible-adult-change-facilities#S27C8","x":"Changing rails must be installed as two horizontal and parallel rails fixed to a wall, not less than 800 mm long, each with a diameter between 30 mm and 40 mm, and—\nthe lower rail must be installed between 800 mm and 810 mm above finished floor level; and\nthe upper rail must be installed between 1000 mm and 1010 mm above finished floor level; and\nthe rails must be able to withstand a force of not less than 1100 N in any direction.","g":"/ncc/s27c8","a19":["Spec F2.9: 8"]},{"c":"S27C9","t":"Door and door controls","p":"Specification 27 Accessible adult change facilities","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/27-accessible-adult-change-facilities#S27C9","x":"The entrance door and associated door controls must be automated and must comply with the following:\nThe threshold must incorporate a smooth transition without a step or lip.\nThe minimum clear opening width must be—\n1100 mm in locations where beach wheelchairs are likely to be used; or\n950 mm in all other locations.\nThe doorway must achieve a luminance contrast of at least 30% between—\ndoor leaf and door jamb; or\ndoor leaf and adjacent wall; or\narchitraves (where used) and adjacent wall; or\ndoor leaf and architrave (where used); or\ndoor jamb and adjacent wall.\nThe operation of the door must be calibrated such that—\nit has a gentle opening and closing movement; and\nthere is sufficient dwell time for a user to safely travel through the doorway.\nThe door must be fitted with a fail-safe opening mechanism that opens the door if an obstruction is detected during its closing movement.\nDoor controls must be located internally and externally—\nbetween 900 mm and 1200 mm above finished floor level; and\nnot less than 500 mm from any internal corner.\nDoor control buttons must—\nhave a minimum diameter of 25 mm; and\nbe proud of the surrounding surface; and\nactivate the door operation before the button becomes level with the surrounding surface; and\nbe of a contrasting colour to the surrounding plate.\nThe surrounding plates of both internal and external door controls must include the words “Push to Open”.\nThe following indicator lights must be provided:\n“Occupied” and “Vacant” on the external plate.\n“Locked” and “Unlocked” on the internal plate.\nBraille and tactile signage complying with Specification 15 must identify the door controls.","g":"/ncc/s27c9","a19":["Spec F2.9: 9"]},{"c":"S27C10","t":"Signage","p":"Specification 27 Accessible adult change facilities","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/27-accessible-adult-change-facilities#S27C10","x":"(1) External signage must incorporate—\nthe symbol shown in Figure S27C10; and\nthe words “Accessible Adult Change Facility”.\n(2) The symbol required by (1)(a) must have a blue (B21, ultramarine) background with the hoist and table elements shown in white.\n(3) Signage must be braille and tactile signage complying with Specification 15.\nFigure S27C10 Accessible adult change facility symbol","g":"/ncc/s27c10","a19":["Spec F2.9: 10"]},{"c":"S27C11","t":"Operating instructions","p":"Specification 27 Accessible adult change facilities","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/27-accessible-adult-change-facilities#S27C11","x":"Signage provided within the facility must include the following information for the hoist and change table:\nOperating instructions.\nSafe working load limits.","g":"/ncc/s27c11","a19":["Spec F2.9: 11"]},{"c":"S28C1","t":"Scope","p":"Specification 28 Sound insulation for building elements","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/28-sound-insulation-building-elements#S28C1","x":"This Specification lists the weighted sound reduction index RW for some common forms of construction.","g":"/ncc/s28c1","a19":["Spec F5.2: 1(a)"]},{"c":"S28C2","t":"Discontinuous construction","p":"Specification 28 Sound insulation for building elements","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/28-sound-insulation-building-elements#S28C2","x":"Wall systems listed in S28C4 to S28C7 having a minimum 20 mm cavity between 2 separate leaves are deemed to be discontinuous construction if—\nfor masonry, where wall ties are required to connect leaves, the ties are of the resilient type; and\nfor other than masonry, there is no mechanical linkage between leaves except at the periphery.","g":"/ncc/s28c2","a19":["NT Spec F5.2: 2","Spec F5.2: 1(b)"]},{"c":"S28C3","t":"Construction Deemed-to-Satisfy","p":"Specification 28 Sound insulation for building elements","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/28-sound-insulation-building-elements#S28C3","x":"(1) The forms of wall construction described in S28C4 to S28C7 and floor construction described in S28C8 to S28C10, are considered to have the Rw, Rw + Ctr and Ln,w stated in those clauses.\n(2) The forms of construction referred to in (1) must be installed as follows:\nMasonry units must be laid with all joints filled solid, including those between the masonry and any adjoining construction.\nJoints between concrete slabs or panels and any adjoining construction must be filled solid.\nFor sheeting materials—\nif one layer is required on both sides of a wall, it must be fastened to the studs with joints staggered on opposite sides; and\nif two layers are required, the second layer must be fastened over the first layer so that the joints do not coincide with those of the first layer; and\njoints between sheets or between sheets and any adjoining construction must be taped and filled solid.\nTimber or steel-framed construction — perimeter framing members must be securely fixed to the adjoining structure and—\nbedded in resilient compound; or\nthe joints must be caulked so that there are no voids between the framing members and the adjoining structure.\nServices must not be chased into concrete or masonry elements.\nA door or panel required to have a certain Rw + Ctr that provides access to a duct, pipe or other service must—\nnot open into any habitable room (other than a kitchen); and\nbe firmly fixed so as to overlap the frame or rebate of the frame by not less than 10 mm, be fitted with a sealing gasket along all edges and be constructed of—\nwood, particleboard or blockboard not less than 33 mm thick; or\ncompressed fibre-reinforced cement sheeting not less than 9 mm thick; or\nother suitable material with a mass per unit area not less than 24.4 kg/m2.\nA water supply pipe must—\nonly be installed in the cavity of discontinuous construction; and\nin the case of a pipe that serves only one sole-occupancy unit, not be fixed to the wall leaf on the side adjoining any other sole-occupancy unit and have a clearance not less than 10 mm to the other wall leaf.\nElectrical outlets must be offset from each other—\nin masonry walling, not less than 100 mm; and\nin timber or steel-framed walling, not less than 300 mm.","g":"/ncc/s28c3","a19":["NT Spec F5.2: Table 2","Spec F5.2: 2"]},{"c":"S28C4","t":"Acceptable forms of construction for walls — masonry","p":"Specification 28 Sound insulation for building elements","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/28-sound-insulation-building-elements#S28C4","x":"(1) Acceptable forms of construction for masonry walls are set out in (2) to (9).\n(2) Two leaves of 110 mm clay brick masonry with—\na cavity of not less than 50 mm between leaves; and\n50 mm thick glass wool insulation with a density of 11 kg/m3 or 50 mm thick polyester insulation with a density of 20 kg/m3 in the cavity,\nhas an Rw + Ctr of not less than 50 and an Rw of not less than 50, if constructed as shown in Figure S28C4a.\n(3) Two leaves of 110 mm clay brick masonry with—\na cavity of not less than 50 mm between leaves; and\n13 mm cement render on each outside face,\nhas an Rw + Ctr of not less than 50 and an Rw of not less than 50, when constructed as shown in Figure S28C4b.\n(4) A single leaf of 110 mm clay brick masonry with—\na row of 70 mm x 35 mm timber studs or 64 mm steel studs at 600 mm centres, spaced 20 mm from the masonry wall; and\n50 mm thick glass or mineral wool insulation with a density of 11 kg/m3 positioned between studs; and\none layer of 13 mm plasterboard fixed to outside face of studs and outside face of masonry,\nhas an Rw + Ctr of not less than 50 and an Rw of not less than 50, if constructed as shown in Figure S28C4c.\n(5) A single leaf of 90 mm clay brick masonry with—\na row of 70 mm x 35 mm timber studs or 64 mm steel studs at 600 mm centres, spaced 20 mm from each face of the masonry wall; and\n50 mm thick glass or mineral wool insulation with a density of 11 kg/m3 positioned between studs in each row; and\none layer of 13 mm plasterboard fixed to studs on each outside face,\nhas an Rw + Ctr of not less than 50 and an Rw of not less than 50, if constructed as shown in Figure S28C4d.\n(6) A single leaf of 150 mm brick masonry with 13 mm cement render on each face has an Rw of not less than 50 if constructed as shown in Figure S28C4e.\n(7) A single leaf of 220 mm brick masonry with 13 mm cement render on each face has an Rw + Ctr of not less than 50 and an Rw of not less than 50, if constructed as shown in Figure S28C4f.\n(8) 110 mm thick brick masonry with 13 mm cement render on each face has an Rw of not less than 45 if constructed as shown in Figure S28C4g.\n(9) 110 mm thick concrete brickwork has an Rw of not less than 45 if constructed as shown in Figure S28C4h.\nFigure S28C4a Two leaves of 110 mm clay brick masonry (method 1)\nFigure S28C4b Two leaves of 110 mm clay brick masonry (method 2)\nFigure S28C4c Single leaf of 110 mm clay brick masonry\nFigure S28C4d Single leaf of 90 mm clay brick masonry\nFigure S28C4e Single leaf of 150 mm brick masonry with 13 mm cement render on each face\nFigure S28C4f Single leaf of 220 mm brick masonry with 13 mm cement render on each face\nFigure S28C4g 110 mm thick brick masonry with 13 mm cement render on each face\nFigure S28C4h 110 mm thick concrete brickwork","g":"/ncc/s28c4","a19":["Spec F5.2: Table 2"]},{"c":"S28C5","t":"Acceptable forms of construction for walls — concrete","p":"Specification 28 Sound insulation for building elements","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/28-sound-insulation-building-elements#S28C5","x":"(1) Acceptable forms of construction for concrete walls are set out in (3) to (12).\n(2) For the purposes of this clause, the term ‘concrete panel’ is a reference to a solid in-situ concrete panel or solid pre-cast concrete panel.\n(3) A 150 mm thick concrete panel has an Rw + Ctr of not less than 50 and an Rw of not less than 50, if constructed as shown in Figure S28C5a.\n(4) A 150 mm thick concrete panel with one layer of 10 mm plasterboard fixed to 28 mm metal furring channels on each face, has an Rw of not less than 50, if constructed as shown in Figure S28C5b.\n(5) A 200 mm thick concrete panel with one layer of 13 mm plasterboard or 13 mm cement render on each face has an Rw + Ctr of not less than 50 and an Rw of not less than 50, if constructed as shown in Figure S28C5c.\n(6) A 100 mm thick concrete panel with—\na row of 64 mm steel studs at 600 mm centres, spaced 25 mm from the concrete panel; and\n80 mm thick polyester insulation or 50 mm thick glass wool insulation with a density of 11 kg/m3, positioned between studs; and\ntwo layers of 13 mm plasterboard fixed to outside face of studs and one layer of 13 mm plasterboard fixed to outside face of concrete panel,\nhas an with an Rw + Ctr of not less than 50 and an Rw of not less than 50, if constructed in accordance with Figure S28C5d.\n(7) A 125 mm thick concrete panel with—\na row of 64 mm steel studs at 600 mm centres, spaced 20 mm from the concrete panel; and\n70 mm polyester insulation with a density of 9 kg/m3, positioned between studs; and\none layer of 13 mm plasterboard fixed to the outside face of the studs,\nhas an with an Rw + Ctr of not less than 50 and an Rw of not less than 50, if constructed in accordance with Figure S28C5e.\n(8) A 125 mm thick concrete panel has an Rw of not less than 50, if constructed as shown in Figure S28C5f.\n(9) A 100 mm concrete panel with 13 mm cement render or one layer of 13 mm plasterboard on each face has an Rw of not less than 50, if constructed as shown in Figure S28C5g.\n(10) A 190 mm thick concrete blockwork has an Rw of not less than 45, if constructed as shown in Figure S28C5h.\n(11) 140 mm thick concrete blockwork, the face shell thickness of the blocks being not less than 44 mm and with—\n50 mm x 50 mm timber battens spaced at not more than 610 mm centres screw-fixed on one face of the blocks into resilient plugs with rubber inserts between battens and the wall; and\nthe face of the battens clad with 13 mm plasterboard,\nhas an Rw of not less than 45, if constructed as shown in Figure S28C5i.\n(12) A concrete panel, 100 mm thick, has an Rw of not less than 45, if constructed as shown in Figure S28C5j.\nFigure S28C5a 150 mm thick concrete panel\nFigure S28C5b 150 mm thick concrete panel with one layer of 10 mm plasterboard fixed to 28 mm metal furring channels on each face\nFigure S28C5c 200 mm thick concrete panel with one layer of 13 mm plasterboard or 13 mm cement render on each face\nFigure S28C5d 100 mm thick concrete panel with studs, insulation and plasterboard\nFigure S28C5e 125 mm thick concrete panel with studs, insulation and plasterboard\nFigure S28C5f 125 mm thick concrete panel\nFigure S28C5g 100 mm concrete panel with 13 mm cement render or one layer of 13 mm plasterboard on each face\nFigure S28C5h 190 mm thick concrete blockwork\nFigure S28C5i 140 mm thick concrete blockwork with timber battens and 13 mm plasterboard\nFigure S28C5j 100 mm thick concrete panel","g":"/ncc/s28c5","a19":["Spec F5.2: Table 2"]},{"c":"S28C6","t":"Acceptable forms of construction for walls — autoclaved aerated concrete","p":"Specification 28 Sound insulation for building elements","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/28-sound-insulation-building-elements#S28C6","x":"(1) Acceptable forms of construction for autoclaved aerated concrete walls are set out in (2) to (5).\n(2) A 75 mm thick autoclaved aerated concrete wall panel with—\na row of 64 mm steel studs at 600 mm centres, spaced 20 mm from the autoclaved aerated concrete wall panel; and\n75 mm thick glass wool insulation with a density of 11 kg/m3 positioned between studs; and\none layer of 10 mm moisture resistant plasterboard or 13 mm fire protective grade plasterboard fixed to outside face of studs and outside face of autoclaved aerated concrete wall panel,\nhas an Rw + Ctr of not less than 50 and an Rw of not less than 50, if constructed as shown in Figure S28C6a.\n(3) A 75 mm thick autoclaved aerated concrete wall panel with—\na row of 64 mm steel studs at 600 mm centres, spaced 35 mm from the autoclaved aerated concrete panel wall; and\n28 mm metal furring channels fixed to the outside face of the autoclaved aerated concrete wall panel, with 50 mm thick polyester insulation with a density of 9 kg/m3 positioned between furring channels and one layer of 13 mm fire protective grade plasterboard fixed to furring channels; and\n105 mm thick glass wool insulation with a density of 7 kg/m3 positioned between studs; and\none layer of 13 mm fire protective grade plasterboard fixed to the outside face of the studs,\nhas an Rw + Ctr of not less than 50 and an Rw of not less than 50, if constructed as shown in Figure S28C6b.\n(4) Two leaves of 75 mm autoclaved aerated concrete wall panel with—\na cavity not less than 30 mm between panels containing 50 mm glass wool insulation with a density of 11 kg/m3; and\none layer of 10 mm plasterboard fixed to outside face of each panel,\nhas an Rw + Ctr of not less than 50 and an Rw of not less than 50, if constructed as shown in Figure S28C6c.\n(5) A 75 mm thick autoclaved aerated concrete wall panel with—\none layer of 10 mm moisture resistant plasterboard on one face; and\n28 mm metal furring channels and resilient mounts, 75 mm polyester insulation with a density of 9 kg/m3 and 13 mm fire-protective grade plasterboard fixed to the other face,\nhas an Rw of not less than 50, if constructed as shown in Figure S28C6d.\nFigure S28C6a 75 mm thick autoclaved aerated concrete wall panel (method 1)\nFigure S28C6b 75 mm thick autoclaved aerated concrete wall panel (method 2)\nFigure S28C6c Two leaves of 75 mm autoclaved aerated concrete wall panel\nFigure S28C6d 75 mm thick autoclaved aerated concrete wall panel (method 3)","g":"/ncc/s28c6","a19":["Spec F5.2: Table 2"]},{"c":"S28C7","t":"Acceptable forms of construction for walls — timber and steel framing","p":"Specification 28 Sound insulation for building elements","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/28-sound-insulation-building-elements#S28C7","x":"(1) Acceptable forms of construction for timber and steel framing walls are set out in (2) to (11).\n(2) Two rows of 70 x 35 mm timber studs at 450 mm centres with—\nan air gap not less than 20 mm between the rows of studs; and\n75 mm thick glass or mineral wool insulation with a density of 8 kg/m³ or 60 mm thick polyester insulation with a density of 11 kg/m³ positioned between one row of studs; and\ntwo layers of 13 mm fire-protective grade plasterboard or one layer of 6 mm fibre-cement sheet and one layer of 13 mm fire-protective grade plasterboard, fixed to outside face of studs,\nhas an Rw + Ctr of not less than 50 and an Rw of not less than 50, if constructed as shown in Figure S28C7a.\n(3) One row of 70 mm x 35 mm staggered timber studs, without noggings between adjacent studs, at not less than 450 mm centres, fixed to 90 mm x 35 mm wall plates with—\n75 mm thick glass or mineral wool insulation with a minimum density of 8 kg/m³ positioned between studs; and\ntwo layers of 13 mm fire-protective grade plasterboard fixed to outside face of studs,\nhas an Rw of not less than 50, if constructed as shown in Figure S28C7b.\n(4) One row of 70 mm x 35 mm timber studs at not less than 600 mm centres with—\n75 mm thick glass or mineral wool insulation with a minimum density of 8 kg/m³ positioned between studs; and\ntwo layers of 13 mm fire-protective grade plasterboard fixed to outside face of studs,\nhas an Rw of not less than 45, if constructed as shown in Figure S28C7c.\n(5) One row of 70 mm x 35 mm timber studs at not less than 450 mm centres with—\n28 mm furring channels installed horizontally on one side; and\ntwo layers of 13 mm fire-protective plasterboard fixed on each face,\nhas an Rw of not less than 45, if constructed as shown in Figure S28C7d.\n(6) Two rows of 64 mm steel studs at 600 mm centres with—\nan air gap not less than 20 mm between the rows of studs; and\n50 mm thick glass wool insulation or 60 mm thick polyester insulation with a density of 11 kg/m³ positioned between one row of studs; and\ntwo layers of 13 mm fire-protective grade plasterboard or one layer of 6 mm fibre-cement sheet and one layer of 13 mm fire-protective grade plasterboard, fixed to outside face of studs,\nhas an Rw + Ctr of not less than 50 and an Rw of not less than 50, if constructed as shown in Figure S28C7e.\n(7) Two rows of 64 mm steel studs at 600 mm centres with—\nan air gap not less than 80 mm between the rows of studs; and\n200 mm thick polyester insulation with a density of 14 kg/m3 positioned between studs; and\none layer of 13 mm fire-protective grade plasterboard and one layer 13 mm plasterboard on one outside face and one layer of 13 mm fire-protective grade plasterboard on the other outside face,\nhas an Rw + Ctr of not less than 50 and an Rw of not less than 50, if constructed as shown in Figure S28C7f.\n(8) One row of 92 mm steel studs at 600 mm centres with—\n50 mm thick glass wool insulation with a density of 11 kg/m3 or 60 mm thick polyester insulation with a density of 8 kg/m3, positioned between studs; and\ntwo layers of 13 mm fire-protective grade plasterboard or one layer of 6 mm fibre-cement sheet and one layer of 13 mm fire-protective grade plasterboard, fixed to each face,\nhas an Rw of not less than 50, if constructed as shown in Figure S28C7g.\n(9) One row of 64 mm steel studs with 2 layers of 16 mm fire-protective grade plasterboard fixed to each face has an Rw of not less than 45, if constructed as shown in Figure S28C7h.\n(10) One row of 64 mm steel studs with—\none layer of 16 mm fire-protective grade plasterboard fixed to one face; and\n50 mm thick glass or mineral wool insulation with a density of 11 kg/m3 positioned between the studs; and\ntwo layers of fire-protective grade plasterboard fixed to the other face, the inner layer being 16 mm thick and the outer layer being 13 mm,\nhas an Rw of not less than 45, if constructed as shown in Figure S28C7i.\n(11) One row of 64 mm steel studs with two layers of 13 mm plasterboard on each face has an Rw of not less than 45, if constructed as shown in Figure S28C7j.\nFigure S28C7a Two rows of 70 mm x 35 mm timber studs\nFigure S28C7b One row of 70 mm x 35 mm staggered timber studs without noggings between adjacent studs\nFigure S28C7c One row of 70 mm x 35 mm timber studs at not less than 600 mm centres\nFigure S28C7d One row of 70 mm x 35 mm timber studs at not less than 450 mm centres\nFigure S28C7e Two rows of 64 mm steel studs at 600 mm centres (Method 1)\nFigure S28C7f Two rows of 64 mm steel studs at 600 mm centres (Method 2)\nFigure S28C7g One row of 92 mm steel studs\nFigure S28C7h One row of 64 mm steel studs with 2 layers of 16 mm fire-protective grade plasterboard\nFigure S28C7i One row of 64 mm steel studs\nFigure S28C7j One row of 64 mm steel studs with two layers of 13 mm plasterboard on each face","g":"/ncc/s28c7","a19":["Spec F5.2: Table 2"]},{"c":"S28C8","t":"Acceptable forms of construction for floors — concrete","p":"Specification 28 Sound insulation for building elements","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/28-sound-insulation-building-elements#S28C8","x":"(1) Acceptable forms of construction for concrete floors are set out in (2) to (4).\n(2) 150 mm thick concrete slab with—\n28 mm metal furring channels and isolation mounts fixed to underside of slab, at 600 mm centres; and\n65 mm thick polyester insulation with a density of 8 kg/m3, positioned between furring channels; and\none layer of 13 mm plasterboard fixed to furring channels,\nhas an Rw + Ctr of not less than 50, an Ln,w of not more than 62 and an Rw of not less than 50, if constructed as shown in Figure S28C8a.\n(3) 200 mm thick concrete slab with carpet on underlay has an Rw + Ctr of not less than 50, an Ln,w of not more than 62 and an Rw of not less than 50, if constructed as shown in Figure S28C8b.\n(4) 100 mm thick concrete slab has an Rw + Ctr of not less than 45 and an Rw of not less than 45, if constructed as shown in Figure S28C8c.\nFigure S28C8a 150 mm thick concrete slab\nFigure S28C8b 200 mm thick concrete slab with carpet on underlay\nFigure S28C8c 100 mm thick concrete slab","g":"/ncc/s28c8","a19":["Spec F5.2: Table 3"]},{"c":"S28C9","t":"Acceptable forms of construction for floors — autoclaved aerated concrete","p":"Specification 28 Sound insulation for building elements","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/28-sound-insulation-building-elements#S28C9","x":"(1) An acceptable form of construction for autoclaved aerated concrete floors is set out in (2).\n(2) 75 mm thick autoclaved aerated concrete floor panel with—\n8 mm ceramic tiles with flexible adhesive and waterproof membrane, located above the slab; and\ntimber joists at 600 mm centres; and\nR1.5 glass wool insulation positioned between timber joists; and\n28 mm metal furring channels and resilient mounts fixed to underside of joists; and\ntwo layers of 13 mm plasterboard fixed to furring channels,\nhas an Rw + Ctr of not less than 50, an Ln,w of not more than 62 and an Rw of not less than 50, if constructed as shown in Figure S28C9.\nFigure S28C9 75 mm thick autoclaved aerated concrete floor panel","g":"/ncc/s28c9","a19":["Spec F5.2: Table 3"]},{"c":"S28C10","t":"Acceptable forms of construction for floors — timber","p":"Specification 28 Sound insulation for building elements","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/28-sound-insulation-building-elements#S28C10","x":"(1) Acceptable forms of construction for timber floors are set out in (2) and (3).\n(2) 19 mm thick particleboard floor sheeting with—\n190 mm x 45 mm timber joists at 450 mm centres; and\nR2.5 glass or mineral wool insulation positioned between timber joists; and\n28 mm metal furring channels and isolation mounts fixed to underside of joists, isolation mounts to be of natural rubber with a dynamic factor of not more than 1.1 and static deflection of not less than 3 mm at actual operating load; and\ntwo layers of 16 mm fire-protective grade plasterboard fixed to furring channels,\nhas an Rw + Ctr of not less than 50, an Ln,w of not more than 62 and an Rw of not less than 50, if constructed as shown in Figure S28C10a.\n(3) Timber flooring with minimum 8.5 kg/m² mass, over 19 mm thick particleboard floor sheeting with—\n190 mm x 45 mm timber joists at not less than 450 mm centres; and\nR2.5 glass or mineral wool insulation positioned between timber joists; and\n28 mm metal furring channels fixed to underside of joists at 600 mm centres by clip or mount; and\none layer of 13 mm acoustic grade plasterboard fixed to furring channels,\nhas an Rw + C of not less than 45 and an Rw of not less than 45, if constructed as shown in Figure S28C10b.\nFigure S28C10a 19 mm thick particleboard floor sheeting\nFigure S28C10b Timber flooring with minimum 8.5kg/m² mass, over 19 mm thick particleboard floor sheeting","g":"/ncc/s28c10","a19":["Spec F5.2: Table 3"]},{"c":"S29C1","t":"Scope","p":"Specification 29 Impact sound – test of equivalence","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/29-impact-sound-test-equivalence#S29C1","x":"This Specification describes a method of test to determine the comparative resistance of walls to the transmission of impact sound.","g":"/ncc/s29c1","a19":["Spec F5.5: 1"]},{"c":"S29C2","t":"Construction to be tested","p":"Specification 29 Impact sound – test of equivalence","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/29-impact-sound-test-equivalence#S29C2","x":"(1) The test is conducted on a specimen of prototype wall construction and on a specimen of one or other of the constructions specified in S28C4 to S28C7.\n(2) The testing of a construction specified in S28C4 to S28C7 need not be repeated for subsequent comparisons provided complete records of the results, the test equipment and the technique of testing are kept so that identical equipment can be employed and an identical technique can be adopted in the testing of specimens of prototype wall construction.","g":"/ncc/s29c2","a19":["NT Spec F5.5: 2","Spec F5.5: 2"]},{"c":"S29C3","t":"Method","p":"Specification 29 Impact sound – test of equivalence","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/29-impact-sound-test-equivalence#S29C3","x":"(1) The wall constructions to be compared must be tested in accordance with AS 1191.\n(2) A horizontal steel platform 510 mm x 460 mm x 10 mm thick must be placed with one long edge in continuous and direct contact with the wall to be tested on the side of the wall on which the impact sound is to be generated.\n(3) A tapping machine complying with ISO 140/6 — 1998 (E) must be mounted centrally on the steel platform.\n(4) The sound transmission through the wall must be determined in accordance with AS 1191 except that the tapping machine as mounted on the steel platform must be used as the source of sound.\n(5) The impact sound pressure levels measured in the receiving room must be converted into normalised levels using a reference equivalent absorption area of 10 m2.","g":"/ncc/s29c3","a19":["Spec F5.5: 3"]},{"c":"F1O1","t":"Objective","p":"Part F1 Water management","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f1-water-management#F1O1","x":"The Objective of this Part is to—\nsafeguard occupants from illness or injury and protect the building from damage caused by the entry of water; and\nprotect other property from damage caused by redirected water.","g":"/ncc/f1o1","a19":["FO1"]},{"c":"F1F1","t":"Protection from water","p":"Part F1 Water management","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f1-water-management#F1F1","x":"A building, including any associated sitework, is to be constructed in a way that protects—\npeople from the adverse effects of water; and\nother property from the adverse effects of redirected water.","g":"/ncc/f1f1","a19":["FF1.1"]},{"c":"F1F2","t":"Resistance to rising damp and ground water","p":"Part F1 Water management","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f1-water-management#F1F2","x":"A building is to be resistant to the effects of water from the ground.","g":"/ncc/f1f2","a19":["FF1.2"]},{"c":"F1P1","t":"Managing rainwater impact on the building and adjoining properties","p":"Part F1 Water management","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f1-water-management#F1P1","x":"(1) Water, including water on the surface of the allotment that is collected by a building or associated sitework, must be redirected to a drainage system to prevent—\nunhealthy or unsafe conditions, or loss of amenity for occupants within the building; and\nundue damage to internal surfaces and other building elements; and\nundue damage or nuisance to other buildings and any other property.\n(2) Water, required to be drained and resulting from a rain event with an annual exceedance probability, with a five-minute duration period, of 5% satisfies (1) if it is—\ndisposed of in a way that avoids the likelihood of damage to the building; and\nconveyed through a drainage system to an appropriate outfall.\n(3) Water resulting from a rain event with an annual exceedance probability, with a five-minute duration period, of 1% collected or concentrated by building elements satisfies (1) if it is disposed of in a way that prevents—\nunhealthy or unsafe conditions, or loss of amenity for occupants within the building; and\nundue damage to internal surfaces and other building elements.\n(4) Water resulting from a rain event in (2) and (3), subject to wind action with an annual exceedance probability of 4%, collected or concentrated by a building satisfies (1) if it is disposed of in a way that prevents—\nunhealthy or unsafe conditions, or loss of amenity for occupants within the building; and\nundue damage to internal surfaces and other building elements.\nNotes\nFor the purposes of F1P1(3)—\nbuilding elements include external walls, openings around windows and external doors, roofs, balconies, podiums, attached awnings, similar horizontal surface parts of a building and stormwater overflow systems; and\nan annual exceedance probability of 5% can be applied to awnings and roofs with or without eaves gutters and where overflow, if applicable, is external to the building.\nExemptions\nF1P1(1), F1P1(3) and F1P1(4) do not apply to—\ncondensation; or\na private garage, tool shed, sanitary compartment or the like separate from, or forming part of, a building used for other purposes; or\nan open spectator stand or open-deck carpark.","g":"/ncc/f1p1","a19":["FP1.1"]},{"c":"Table F1V1a","t":"Risk factors and scores","p":"Part F1 Water management","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f1-water-management#_e79b6c14-b48d-4203-b106-30bd43ef4e51","x":"Risk factor | Category | Risk severity | Score\nWind region | Region A0-5 (AS/NZS 1170.2) | Low to medium | 0\nRegion B1-2 (AS/NZS 1170.2)\nRegion C (AS/NZS 1170.2) | High | 1\nRegion D (AS/NZS 1170.2) | Very high | 2\nNumber of storeys | One storey | Low | 0\nTwo storeys in part | Medium | 1\nTwo storeys | High | 2\nMore than two storeys | Very high | 4\nRoof/wall junctions | Roof-to-wall junctions fully protected | Low | 0\nRoof-to-wall junctions partially exposed | Medium | 1\nRoof-to-wall junctions fully exposed | High | 3\nRoof elements finishing within the boundaries formed by the external walls | Very high | 5\nEaves width | More than 600 mm for single storey | Low | 0\n451-600 mm for single storey | Medium | 1\nMore than 600 mm for two storey\n101-450 mm for single storey | High | 2\n451-600 mm for two storey\nMore than 600 mm for above two storey\n0-100 mm for single storey | Very high | 5\n0-450 mm for two storey\nLess than 600 mm for above two storey\nEnvelope complexity | Simple shape with single cladding type | Low | 0\nComplex shape with not more than two cladding types | Medium | 1\nComplex shape with more than two cladding types | High | 3\nAs for high risk but with fully exposed roof-to-wall junctions | Very high | 6\nDecks, porches and balconies | None | Low | 0\nTimber slat deck or porch at ground level\nFully covered in plan view by roof | Medium | 2\nTimber slat deck attached at first or second floor level\nBalcony exposed in plan view at first floor level | High | 4\nBalcony cantilevered at first floor level\nBalcony exposed in plan view at second floor level or above | Very high | 6\nBalcony cantilevered at second floor level or above\nTable Notes\nEaves width is measured horizontally from the external face of any wall cladding to the outer edge of any overhang, including fascia and external gutters.\nBarriers to prevent falling and parapets are considered as 0 mm eaves.","tb":"F1V1","g":"/ncc/table-f1v1a"},{"c":"Table F1V1b","t":"Cyclic pressure","p":"Part F1 Water management","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f1-water-management#_59375c0c-b027-43c0-b528-f9ba1ab605a6","x":"Stage number | Serviceability wind pressure (%)\nMin | Max\n1 | 15 | 30\n2 | 20 | 40\n3 | 30 | 60","tb":"F1V1","g":"/ncc/table-f1v1b"},{"c":"F1V1","t":"Weatherproofing","p":"Part F1 Water management","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f1-water-management#F1V1","x":"(1) Compliance with F1P1 for weatherproofing of an external wall is verified when—\na prototype passes the procedure described in (2); and\nthe external wall —\nhas a risk score of 20 or less, when the sum of all risk factor scores are determined in accordance with Table F1V1a; and\nincludes only windows that comply with AS 2047.\n(2) The test procedure referred to in (1)(a) must be as follows:\nThe test specimen is in accordance with the requirements of (3).\nThe test procedure is in accordance with the requirements of (4) or (5) as applicable.\nThe test specimen does not fail the criteria in (6).\nThe test is recorded in accordance with the requirements of (7).\n(3) Test specimen: The test specimen must be a minimum of 2.4 m high and 2.4 m wide and incorporate—\nrepresentative samples of openings and joints, including—\nvertical and horizontal control joints; and\nwall junctions; and\nwindows or doors; and\nelectrical boxes; and\nbalcony drainage and parapet flashings; and\nfooter and header termination systems; and\nfor a cavity wall —\na transparent material for a proportion of the internal wall lining (to provide an unobstructed view of the external wall cladding) with sufficient structural capability and similar air tightness to resist the applied wind pressures; and\na 15 mm diameter hole in the internal wall lining below a window.\n(4) The test procedure for a direct fix cladding wall or unique wall must be as follows:\nApply 100% positive and negative serviceability wind pressures to the external face of the test specimen for a period of not less than 1 minute each.\nApply static pressure of either 300 Pa or 30% serviceability wind pressure, whichever is higher, in accordance with the water penetration test procedure at clause 8.5.2 of AS/NZS 4284.\nApply cyclic pressure in accordance with—\nthe three stages of Table F1V1b; and\nthe water penetration test procedure at clause 8.6.2 of AS/NZS 4284.\n(5) The test procedure for a cavity wall must be as follows:\nApply 100% positive and negative serviceability wind pressures to the external face of the test specimen for a period of not less than 1 minute each.\nApply static pressure of either 300 Pa or 30% serviceability wind pressure, whichever is higher, in accordance with the water penetration test procedure at clause 8.5.2 of AS/NZS 4284.\nApply cyclic pressure in accordance with—\nstage 3 of Table F1V1b; and\nthe water penetration test procedure at clause 8.6.2 of AS/NZS 4284.\nTo simulate the failure of the primary weather-defence or sealing, the following procedure must be applied to the test specimen:\nInsert 6 mm diameter holes through the external face of the cavity wall in all places specified below:\nWall/window or wall/door junctions at ¾ height.\nImmediately above the head flashing.\nThrough external sealing of the horizontal and vertical joints.\nAbove any other penetration detail not covered by (A) to (C).\nRepeat the static and cyclic pressure tests of (b) and (c).\nWithin 30 minutes of the completion of (ii), remove the internal lining of the cavity wall and check for compliance with (6).\nWith the internal lining removed, apply a final static pressure test at 50 Pa for a period of 15 minutes and check for compliance with (6).\n(6) Compliance is determined as follows:\nA direct fix cladding wall and unique wall are verified for compliance with F1P1 if there is no presence of water on the inside surface of the facade.\nA cavity wall is verified for compliance with F1P1 if there is no presence of water on the removed surface of the cavity, except that during the simulation of the failure of the primary weather-defence or sealing, water may—\ntransfer to the removed surface of the cavity due to the introduced defects (6 mm holes); and\ncontact, but not pool on, battens and other cavity surfaces.\n(7) The test report must include the following information:\nName and address of the person supervising the test.\nTest report number.\nDate of the test.\nCladding manufacturer’s name and address.\nConstruction details of the test specimen, including a description, and drawings and details of the components, showing modifications, if any.\nTest sequence with the pressures used in all tests.\nFor each of the static and cyclic pressure tests, full details of all leakages, including position, extent and timing.\nTable F1V1a Risk factors and scores\nRisk factor\nCategory\nRisk severity\nScore\nWind region\nRegion A0-5 (AS/NZS 1170.2)\nLow to medium\n0\nRegion B1-2 (AS/NZS 1170.2)\nRegion C (AS/NZS 1170.2)\nHigh\n1\nRegion D (AS/NZS 1170.2)\nVery high\n2\nNumber of storeys\nOne storey\nLow\n0\nTwo storeys in part\nMedium\n1\nTwo storeys\nHigh\n2\nMore than two storeys\nVery high\n4\nRoof/wall junctions\nRoof-to-wall junctions fully protected\nLow\n0\nRoof-to-wall junctions partially exposed\nMedium\n1\nRoof-to-wall junctions fully exposed\nHigh\n3\nRoof elements finishing within the boundaries formed by the external walls\nVery high\n5\nEaves width\nMore than 600 mm for single storey\nLow\n0\n451-600 mm for single storey\nMedium\n1\nMore than 600 mm for two storey\n101-450 mm for single storey\nHigh\n2\n451-600 mm for two storey\nMore than 600 mm for above two storey\n0-100 mm for single storey\nVery high\n5\n0-450 mm for two storey\nLess than 600 mm for above two storey\nEnvelope complexity\nSimple shape with single cladding type\nLow\n0\nComplex shape with not more than two cladding types\nMedium\n1\nComplex shape with more than two cladding types\nHigh\n3\nAs for high risk but with fully exposed roof-to-wall junctions\nVery high\n6\nDecks, porches and balconies\nNone\nLow\n0\nTimber slat deck or porch at ground level\nFully covered in plan view by roof\nMedium\n2\nTimber slat deck attached at first or second floor level\nBalcony exposed in plan view at first floor level\nHigh\n4\nBalcony cantilevered at first floor level\nBalcony exposed in plan view at second floor level or above\nVery high\n6\nBalcony cantilevered at second floor level or above\nTable Notes\nEaves width is measured horizontally from the external face of any wall cladding to the outer edge of any overhang, including fascia and external gutters.\nBarriers to prevent falling and parapets are considered as 0 mm eaves.\nTable F1V1b Cyclic pressure\nStage number\nServiceability wind pressure (%)\nMin\nMax\n1\n15\n30\n2\n20\n40\n3\n30\n60","g":"/ncc/f1v1"},{"c":"F1D1","t":"Deemed-to-Satisfy Provisions","p":"Part F1 Water management","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f1-water-management#F1D1","x":"(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements F1P1 is satisfied by complying with F1D2 to F1D15.\n(2) Where a Performance Solution is proposed, the relevant Performance Requirements must be determined in accordance with A2G2(3) and A2G4(3) as applicable.","g":"/ncc/f1d1","a19":["F1.0"]},{"c":"F1D2","t":"Application of Part","p":"Part F1 Water management","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f1-water-management#F1D2","x":"(1) F1D4 to F1D7 and F1D10 do not apply to a roof with a covering complying with F1D12(a) to (d).\n(2) F1D3 to F1D7 and F1D10 do not apply to—\ntimber decking or other perforated flooring to a balcony, podium or similar horizontal surface part of a building; or\na balcony, podium or similar horizontal surface part of a building which is located directly above ground.\n(3) F1D3 to F1D15 do not apply to horizontal or near horizontal surfaces created by window hoods, spandrels, tops of parapets and other features.\n(4) For the purpose of this Part, reference to a horizontal element includes reference to a near horizontal element.","g":"/ncc/f1d2"},{"c":"F1D3","t":"Stormwater drainage","p":"Part F1 Water management","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f1-water-management#F1D3","x":"Stormwater drainage must be designed and constructed in accordance with AS/NZS 3500.3.","g":"/ncc/f1d3","a19":["F1.1"]},{"c":"F1D4","t":"Provision of drainage and grading to external areas","p":"Part F1 Water management","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f1-water-management#F1D4","x":"A concrete roof, balcony, podium or similar part of a building must have—\na drainage system complying with F1D3 that incorporates sufficient overflow provision: and\nits structural substrate graded with a minimum fall of 1:80 in the plane of the substrate to suit the drainage system required by (a); and\na minimum 70 mm step down from the surface level of the internal floor structural substrate to the adjacent surface level of the external structural substrate, where applicable; and\na monolithic hob that is integral with the structural substrate, at least 70 mm high, installed at the outer perimeter, except where the perimeter of the roof, balcony, podium or similar part of the building drains directly to a gutter.\nNotes\nThe invert level of overflow provision referred to in F1D4(a) must be installed not less than 20 mm below any adjacent internal floor structural substrate.\nFor the purposes of Section F, the plane of the floor or substrate is taken to mean the predominant fall of the surface in question, typically perpendicular to bounding walls and is not a reference to the diagonal intersection between planes.\nFor the purposes of this Part, a tile bed, screed, topping or similar component is not considered a structural substrate except within planter boxes where it can be used to achieve the minimum fall of 1:80.\nF1D4(d) does not prevent penetration of a hob for the provision of overflow.\nThe minimum 70 mm step down reference in F1D4(c) is not intended to refer to the minimum waterproofing termination height specified in AS 4654.2. Where AS 4654.2 requires a termination height greater than 70 mm, the waterproof membrane termination can be extended by suitable means above the 70 mm concrete set down.","g":"/ncc/f1d4"},{"c":"F1D5","t":"Substrate materials","p":"Part F1 Water management","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f1-water-management#F1D5","x":"(1) In a building or part of a building, where a roof, balcony, podium, or similar part of a building is constructed of concrete, it must comply with AS 3600.\n(2) The surface of structural substrates in (1) must be prepared in accordance with F1D7(1)(b) to be suitable for application of a membrane.","g":"/ncc/f1d5","a19":["F1.4"]},{"c":"F1D6","t":"Exposed joints","p":"Part F1 Water management","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f1-water-management#F1D6","x":"Exposed joints in the drainage surface on a roof, balcony, podium or similar horizontal surface part of a building must—\nbe located on the ridge line or high point of the structural substrate; and\nbe protected in accordance with Section 2.9 of AS 4654.2; and\nnot be located beneath or run through a planter box, water feature or similar part of the building.\nNotes\nFor the purposes of F1D6, an exposed joint is a construction joint, control joint, expansion joint, contraction joint or movement joint and includes an exposed joint which is directly below a drainage surface.","g":"/ncc/f1d6","a19":["F1.9"]},{"c":"F1D7","t":"External waterproofing membranes","p":"Part F1 Water management","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f1-water-management#F1D7","x":"(1) A roof, balcony, podium or similar horizontal surface part of a building must be provided with a waterproofing membrane —\nconsisting of materials complying with AS 4654.1; and\ndesigned and installed in accordance with AS 4654.2.\n(2) Where a membrane required by (1) is applied to a concrete roof, balcony, podium or similar horizontal surface, the membrane must be installed directly on a structural substrate complying with F1D5.","g":"/ncc/f1d7","a19":["SA F1.10","F1.10"]},{"c":"F1D8","t":"Damp-proofing","p":"Part F1 Water management","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f1-water-management#F1D8","x":"(1) Except for a building covered by (3), moisture from the ground must be prevented from reaching—\nthe lowest floor timbers and the walls above the lowest floor joists; and\nthe walls above the damp-proof course; and\nthe underside of a suspended floor constructed of a material other than timber, and the supporting beams or girders.\n(2) Where a damp-proof course is provided, it must consist of—\na material that complies with AS/NZS 2904; or\nimpervious sheet material in accordance with AS 3660.1.\n(3) The following buildings need not comply with (1):\nA private garage, tool shed, sanitary compartment, or the like, separate from or forming part of a building used for other purposes.\nAn open spectator stand or open-deck carpark.","g":"/ncc/f1d8","a19":["F1.12"]},{"c":"F1D9","t":"Damp-proofing of floors on the ground","p":"Part F1 Water management","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f1-water-management#F1D9","x":"(1) If a floor of a room is laid on the ground or on fill, moisture from the ground must be prevented from reaching the upper surface of the floor and adjacent walls by the insertion of a vapour barrier in accordance with AS 2870.\n(2) The requirements of (1) do not apply where—\nweatherproofing is not required; or\nthe floor is the base of a stair, lift or similar shaft which is adequately drained by gravitation or mechanical means.","g":"/ncc/f1d9"},{"c":"F1D10","t":"Surface finishes","p":"Part F1 Water management","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f1-water-management#F1D10","x":"In a building or part of a building, the flooring or surface finish of a roof, balcony, terrace, podium, or similar part of a building must be—\nself-draining; or\ndirectly fixed to a membrane complying with F1D7.\nLimitations\nF1D10(a) does not apply to areas subject to vehicular traffic or limited trafficability stone/pebble coverings (ballast) to roof membranes","g":"/ncc/f1d10"},{"c":"Table F1D11","t":"Subfloor openings and ground clearance","p":"Part F1 Water management","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f1-water-management#_ee294f41-cddf-4537-80e9-0f73c23df2d1","x":"Climatic zone (see Figure F1D11) | Minimum aggregate subfloor ventilation openings without a membrane (mm2/m of wall) | Minimum aggregate subfloor ventilation openings having the ground sealed with an impervious membrane (mm2/m of wall) | Minimum ground clearance height where termite inspection or management system is not required (mm) | Minimum ground clearance height where termite inspection is required (mm) Note 1\nA | 2000 | 1000 | 150 | 400\nB | 4000 | 2000 | 150 | 400\nC | 6000 | 3000 | 150 | 400\nTable Notes\n400 mm clearance required only where termite management systems are installed that need to be inspected (see B1D4).\nOn sloping sites, the 400 mm clearance required by (1) may be reduced to 150 mm within 2 m of external walls.\nIn situations where openings in external walls and internal subfloor walls are not able to be provided, additional measures must be provided to ensure that the overall level of ventilation of the subfloor space is maintained.\nAdditional measures referred to in (3) may include measures similar to those in F1D11(5), such as providing durability class timbers, or having the ground sealed in the subfloor space with an impervious membrane.","tb":"F1D11","g":"/ncc/table-f1d11"},{"c":"F1D11","t":"Subfloor ventilation","p":"Part F1 Water management","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f1-water-management#F1D11","x":"(1) Subfloor spaces must—\nbe provided with openings in external walls and internal subfloor walls in accordance with Table F1D11 for the climatic zones given in Figure F1D11; and\nhave clearance between the ground surface and the underside of the lowest horizontal member in the subfloor in accordance with Table F1D11.\n(2) In addition to (1), a subfloor space must—\nbe cleared of all building debris and vegetation; and\nhave the ground beneath the suspended floor graded to prevent water ponding under the building; and\ncontain no dead air spaces; and\nhave openings evenly spaced as far as practicable; and\nhave openings placed not more than 600 mm in from corners.\n(3) In double leaf masonry walls, openings specified in (1) must be provided in both leaves of the masonry, with openings being aligned to allow an unobstructed flow of air.\n(4) Openings in internal subfloor walls specified in (1) must have an unobstructed area equivalent to that required for the adjacent external openings.\n(5) Where the ground or subfloor space is excessively damp or subject to frequent flooding, in addition to the requirements of (1) to (4)—\nthe subfloor ventilation required in (1) must be increased by 50%; or\nthe ground within the subfloor space must be sealed with an impervious membrane; or\nsubfloor framing must be—\nwhere above ground, above-ground durability Class 1 or 2 timbers or H3 preservative treated timbers in accordance with AS 1684.2, AS 1684.3 or AS 1684.4; or\nwhere in ground, in-ground durability Class 1 or 2 timbers or H5 preservative treated timbers in accordance with AS 1684.2, AS 1684.3 or AS 1684.4; or\nsteel in accordance with NASH Standard ‘Residential and Low-Rise Steel Framing’ Part 2.\nTable F1D11 Subfloor openings and ground clearance\nClimatic zone (see Figure F1D11)\nMinimum aggregate subfloor ventilation openings without a membrane (mm2/m of wall)\nMinimum aggregate subfloor ventilation openings having the ground sealed with an impervious membrane (mm2/m of wall)\nMinimum ground clearance height where termite inspection or management system is not required (mm)\nMinimum ground clearance height where termite inspection is required (mm) Note 1\nA\n2000\n1000\n150\n400\nB\n4000\n2000\n150\n400\nC\n6000\n3000\n150\n400\nTable Notes\n400 mm clearance required only where termite management systems are installed that need to be inspected (see B1D4).\nOn sloping sites, the 400 mm clearance required by (1) may be reduced to 150 mm within 2 m of external walls.\nIn situations where openings in external walls and internal subfloor walls are not able to be provided, additional measures must be provided to ensure that the overall level of ventilation of the subfloor space is maintained.\nAdditional measures referred to in (3) may include measures similar to those in F1D11(5), such as providing durability class timbers, or having the ground sealed in the subfloor space with an impervious membrane.\nFigure F1D11 Climatic zones based on relative humidity\nFigure Notes\nThe season with the highest relative humidity is used. Generally this will be July for southern Australia and January for northern Australia.","g":"/ncc/f1d11"},{"c":"F1D12","t":"Roof coverings","p":"Part F1 Water management","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f1-water-management#F1D12","x":"A roof must be covered with—\nroof tiles complying with AS 2049, fixed in accordance with AS 2050; or\nmetal sheet roofing complying with AS 1562.1; or\nplastic sheet roofing designed and installed in accordance with AS 1562.3; or\nterracotta, fibre-cement and timber slates and shingles designed and installed in accordance with AS 4597, except in cyclonic areas; or\nan external waterproofing membrane complying with F1D7.","g":"/ncc/f1d12"},{"c":"F1D13","t":"Sarking","p":"Part F1 Water management","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f1-water-management#F1D13","x":"Sarking-type material used for weatherproofing of roofs and walls must comply with AS 4200.1 and AS 4200.2.","g":"/ncc/f1d13"},{"c":"F1D14","t":"Glazed assemblies","p":"Part F1 Water management","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f1-water-management#F1D14","x":"(1) Subject to (2) and (3), the following glazed assemblies in an external wall, must comply with AS 2047 requirements for resistance to water penetration:\nWindows.\nSliding and swinging glazed doors with a frame, including french and bi-fold doors with a frame.\nAdjustable louvres.\nShopfronts.\nWindow walls with one piece framing.\n(2) The following buildings need not comply with (1):\nA private garage, tool shed, sanitary compartment, or the like, forming part of a building used for other purposes, except where the construction of the garage, tool shed, sanitary compartment or the like contributes to the weatherproofing of the other part of the building.\nAn open spectator stand or open-deck carpark.\n(3) The following glazed assemblies need not comply with (1):\nAll glazed assemblies not in an external wall.\nRevolving doors.\nFixed louvres.\nSkylights, roof lights and windows in other than the vertical plane.\nSliding and swinging glazed doors without a frame.\nWindows constructed on site and architectural one-off windows, which are not design tested in accordance with AS 2047.\nSecond-hand windows, re-used windows and recycled windows.\nHeritage windows.","g":"/ncc/f1d14"},{"c":"F1D15","t":"Wall cladding","p":"Part F1 Water management","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f1-water-management#F1D15","x":"(1) External wall cladding must comply with one or a combination of the following:\nMasonry, including masonry veneer, unreinforced and reinforced masonry: AS 3700.\nAutoclaved aerated concrete: AS 5146.3.\nMetal wall cladding: AS 1562.1.\n(2) The following buildings need not comply with (1):\nA private garage, tool shed, sanitary compartment, or the like, forming part of a building used for other purposes, except where the construction of the garage, tool shed, sanitary compartment or the like contributes to the weatherproofing of another part of the building that is required to be weatherproofed.\nAn open spectator stand or open deck carpark.","g":"/ncc/f1d15"},{"c":"F2O1","t":"Objective","p":"Part F2 Wet areas and overflow protection","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f2-wet-areas-and-overflow-protection#F2O1","x":"The Objective of this Part is to—\nsafeguard occupants from illness or injury and protect buildings from damage caused by—\ninternal water from wet areas; and\nthe accumulation of internal moisture in the building; and\nprotect other property from damage caused by redirected internal water from wet areas.","g":"/ncc/f2o1"},{"c":"F2F1","t":"Wet areas","p":"Part F2 Wet areas and overflow protection","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f2-wet-areas-and-overflow-protection#F2F1","x":"A building including internal wet areas is to be constructed in a way that protects people, the building and other property from the adverse effects of internal water from wet areas.","g":"/ncc/f2f1"},{"c":"F2F2","t":"Overflow from bathrooms and laundries","p":"Part F2 Wet areas and overflow protection","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f2-wet-areas-and-overflow-protection#F2F2","x":"A building is to be constructed to avoid the likelihood of—\nthe creation of unhealthy or dangerous conditions; and\ndamage to building elements,\ncaused by dampness or water overflow from bathrooms, laundries and the like.","g":"/ncc/f2f2","a19":["FF1.3"]},{"c":"F2P1","t":"Wet area overflows","p":"Part F2 Wet areas and overflow protection","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f2-wet-areas-and-overflow-protection#F2P1","x":"Overflow from a bathroom, laundry facility or the like must be prevented from penetrating to—\nanother sole-occupancy unit used for sleeping accommodation; and\na public space,\nin a storey below in the same building.","g":"/ncc/f2p1","a19":["SA FP1.6","FP1.6"]},{"c":"F2P2","t":"Wet areas","p":"Part F2 Wet areas and overflow protection","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f2-wet-areas-and-overflow-protection#F2P2","x":"To protect the structure of the building and to maintain the amenity of the occupants, water must be prevented from penetrating—\nbehind fittings and linings; and\ninto concealed spaces,\nof sanitary compartments, bathrooms, laundries and the like.","g":"/ncc/f2p2","a19":["FP1.7"]},{"c":"F2V1","t":"Overflow protection","p":"Part F2 Wet areas and overflow protection","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f2-wet-areas-and-overflow-protection#F2V1","x":"Compliance with F2P1 is verified when the flow rate of the in-built overflow for all vessels in the room is greater than the flow rate of the source filling the vessel.\nApplications\nF2V1 only applies to bathrooms, laundries and the like in a Class 2 or 3 building or a Class 4 part of a building.","g":"/ncc/f2v1","a19":["FV1.2"]},{"c":"F2D1","t":"Deemed-to-Satisfy Provisions","p":"Part F2 Wet areas and overflow protection","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f2-wet-areas-and-overflow-protection#F2D1","x":"(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements F2P1 and F2P2 are satisfied by complying with F2D2 to F2D4.\n(2) Where a Performance Solution is proposed, the relevant Performance Requirements must be determined in accordance with A2G2(3) and A2G4(3) as applicable.","g":"/ncc/f2d1"},{"c":"F2D2","t":"Wet area construction","p":"Part F2 Wet areas and overflow protection","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f2-wet-areas-and-overflow-protection#F2D2","x":"(1) In a Class 2 and 3 building and a Class 4 part of a building, building elements in wet areas must—\nbe water resistant or waterproof in accordance with Specification 26; and\ncomply with AS 3740.\n(2) In a Class 5, 6, 7, 8 or 9 building, building elements in a bathroom or shower room, a slop hopper or sink compartment, a laundry or sanitary compartment must—\nbe water resistant or waterproof in accordance with Specification 26; and\ncomply with AS 3740,\nas if they were in a Class 2 or 3 building or a Class 4 part of a building.","g":"/ncc/f2d2","a19":["F1.7(a) and (b)"]},{"c":"F2D3","t":"Rooms containing urinals","p":"Part F2 Wet areas and overflow protection","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f2-wet-areas-and-overflow-protection#F2D3","x":"(1) Where a slab or stall type urinal is installed—\nthe floor surface of the room containing the urinal must be an impervious material; and\nwhere no step is installed, must—\nbe graded to the urinal channel for a distance of 1.5 m from the urinal channel; and\nhave the remainder of the floor graded to a floor waste; and\nwhere a step is installed—\nthe step must have an impervious surface and be graded to the urinal channel; and\nthe floor behind the step must be graded to a floor waste; and\nthe junction between the floor surface and the urinal channel must be impervious.\n(2) Where a wall hung urinal is installed—\nthe wall must be surfaced with impervious material extending from the floor to not less than 50 mm above the top of the urinal and not less than 225 mm on each side of the urinal; and\nthe floor must be surfaced with an impervious material and be graded to a floor waste.\n(3) In a room with timber or steel-framed walls and containing a urinal—\nthe wall must be surfaced with an impervious material extending from the floor to not less than 100 mm above the floor surface; and\nthe junction of the floor surface and the wall surface must be impervious.","g":"/ncc/f2d3","a19":["F1.7(c)","(d) and (e)"]},{"c":"F2D4","t":"Floor wastes","p":"Part F2 Wet areas and overflow protection","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f2-wet-areas-and-overflow-protection#F2D4","x":"(1) In a Class 2 or 3 building or Class 4 part of a building, a bathroom or laundry located at any level above a sole-occupancy unit or public space must have a floor waste.\n(2) Where a floor waste is installed—\nthe minimum continuous fall of a floor plane to the waste must be 1:80; and\nthe maximum continuous fall of a floor plane to the waste must be 1:50.","g":"/ncc/f2d4","a19":["SA F1.11","F1.11"]},{"c":"F4O1","t":"Objectives","p":"Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f4-sanitary-and-other-facilities#F4O1","x":"The Objective of this Part is to—\nsafeguard occupants from illness caused by infection; and\nsafeguard occupants from loss of amenity arising from the absence of adequate personal hygiene facilities; and\nenable occupants to carry out laundering; and\nprovide for facilities to enable food preparation; and\nenable unconscious occupants of sanitary compartments to be removed from the compartment.","g":"/ncc/f4o1","a19":["FO2"]},{"c":"F4F1","t":"Sanitary facilities","p":"Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f4-sanitary-and-other-facilities#F4F1","x":"A building is to be provided with—\nsuitable sanitary facilities and space and facilities for personal hygiene; and\nadequate means for the prevention of contaminants to hot water, warm water and cooling water systems.","g":"/ncc/f4f1","a19":["FF2.1"]},{"c":"F4F2","t":"Laundry facilities","p":"Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f4-sanitary-and-other-facilities#F4F2","x":"A building is to be provided with—\nspace or facilities for laundering; and\nsuitable means for the sanitary disposal of waste water.\nApplications\nF4F2 only applies to—\na Class 2 building or a Class 4 part of a building; and\na Class 9a health-care building; and\na Class 9b early childhood centre; and\na Class 9c building.","g":"/ncc/f4f2","a19":["FF2.2"]},{"c":"F4F3","t":"Food preparation facilities","p":"Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f4-sanitary-and-other-facilities#F4F3","x":"A building is to be provided with—\nspace and facilities for the preparation and cooking of food; and\nsuitable means for the sanitary disposal of associated waste water.\nApplications\nF4F3 only applies to—\na Class 2 building or a Class 4 part of a building; and\na Class 9a health-care building; and\na Class 9b early childhood centre; and\na Class 9c building.","g":"/ncc/f4f3","a19":["FF2.3"]},{"c":"F4F4","t":"Removal of unconscious occupant","p":"Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f4-sanitary-and-other-facilities#F4F4","x":"A sanitary compartment is to have sufficient space or other means to permit an unconscious occupant to be removed from the compartment.","g":"/ncc/f4f4","a19":["FF2.4"]},{"c":"F4P1","t":"Personal hygiene facilities","p":"Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f4-sanitary-and-other-facilities#F4P1","x":"Suitable sanitary facilities for personal hygiene must be provided in a convenient location within or associated with a building, to the degree necessary, appropriate to—\nthe function or use of the building; and\nthe number and gender of the occupants; and\nthe disability or other particular needs of the occupants.","g":"/ncc/f4p1","a19":["FP2.1"]},{"c":"F4P2","t":"Laundry facilities","p":"Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f4-sanitary-and-other-facilities#F4P2","x":"Laundering facilities or space for laundering facilities and the means for the sanitary disposal of waste water must be provided in a convenient location within or associated with a building appropriate to the function or use of the building.\nApplications\nF4P2 only applies to—\na Class 2 building or Class 4 part of a building; and\na Class 9a health-care building; and\na Class 9b early childhood centre; and\na Class 9c building.","g":"/ncc/f4p2","a19":["VIC FP2.2 Application","FP2.2"]},{"c":"F4P3","t":"Kitchen facilities","p":"Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f4-sanitary-and-other-facilities#F4P3","x":"A facility must be provided which includes—\na means for food rinsing, utensil washing and the sanitary disposal of associated waste water; and\na means for cooking food; and\na space for food preparation.\nApplications\nF4P3 only applies to—\na Class 2 building or Class 4 part of a building; and\na Class 9a health-care building; and\na Class 9b early childhood centre; and\na Class 9c building.","g":"/ncc/f4p3","a19":["FP2.3"]},{"c":"F4P4","t":"Disposal of contaminated water from containers","p":"Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f4-sanitary-and-other-facilities#F4P4","x":"Suitable means must be provided in a building containing wards or bedrooms to facilitate the emptying of sewage or dirty water from containers.\nApplications\nF4P4 only applies to a Class 9a or 9c building.","g":"/ncc/f4p4","a19":["FP2.4"]},{"c":"F4P5","t":"Construction of sanitary compartments to allow removal of unconscious people","p":"Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f4-sanitary-and-other-facilities#F4P5","x":"A sanitary compartment must be constructed with sufficient space or other means to permit an unconscious occupant to be removed from the compartment.","g":"/ncc/f4p5","a19":["FP2.5"]},{"c":"F4P6","t":"Microbial control for water systems","p":"Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f4-sanitary-and-other-facilities#F4P6","x":"Hot water, warm water and cooling water systems installed in a building must control the accumulation of harmful levels of micro-organisms.\nLimitations\nF4P6 does not apply to a system serving only a single sole-occupancy unit in a Class 2 or 3 building or Class 4 part of a building.","g":"/ncc/f4p6","a19":["FP2.6"]},{"c":"F4V1","t":"Sanitary facilities","p":"Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f4-sanitary-and-other-facilities#F4V1","x":"(1) Compliance with F4P1, for the number of sanitary facilities, is verified when queuing modelling predicts that occupant waiting time for sanitary facilities is at least equivalent to the waiting time predicted using the respective Deemed-to-Satisfy Provisions.\n(2) For calculations performed under (1), the occupant waiting time is determined as the 90th percentile wait time at maximum population.\n(3) Queuing modelling in (1) must reflect the following:\nFunction or use of the building.\nNumber and gender of occupants.\nThe disability or other particular needs of the occupants.\nOccupant usage patterns.","g":"/ncc/f4v1","a19":["FV2.1"]},{"c":"F4D1","t":"Deemed-to-Satisfy Provisions","p":"Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f4-sanitary-and-other-facilities#F4D1","x":"(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements F4P1 to F4P6 are satisfied by complying with—\nF4D2 to F4D12; and\nfor public transport buildings, Part I2; and\nfor farm sheds, Part I3.\n(2) Where a Performance Solution is proposed, the relevant Performance Requirements must be determined in accordance with A2G2(3) and A2G4(3) as applicable.","g":"/ncc/f4d1","a19":["F2.0"]},{"c":"F4D2","t":"Facilities in residential buildings","p":"Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f4-sanitary-and-other-facilities#F4D2","x":"(1) For facilities in Class 2 buildings, the following applies:\nWithin each sole-occupancy unit, provide—\na kitchen sink and facilities for the preparation and cooking of food; and\na bath or shower; and\na closet pan; and\na washbasin.\nFor laundry facilities, provide either—\nin each sole-occupancy unit —\nclothes washing facilities, comprising at least one washtub and a space for a washing machine; and\nclothes drying facilities comprising clothes line or a hoist with not less than 7.5 m of line, or space for one heat operated drying cabinet or appliance in the same room as the clothes washing facilities; or\na separate laundry for each 4 sole-occupancy units, or part thereof, that must comprise—\nclothes washing facilities, comprising at least one washtub and a space for a washing machine; and\nclothes drying facilities comprising clothes line or a hoist with not less than 7.5 m of line per sole-occupancy unit, or space for one heat operated drying cabinet or appliance.\nFor the purposes of (a) and (b), a kitchen sink or washbasin must not be counted as a laundry washtub.\n(2) For facilities in Class 3 buildings other than residential care buildings, the following applies:\nFor residents in each building or group of buildings, for each 10 residents for whom private facilities are not provided, provide—\na bath or shower; and\na closet pan; and\na washbasin.\nNotwithstanding (a), if one urinal is provided for each 25 males up to 50 and one additional urinal for each additional 50 males or part thereof, one closet pan for each 12 males may be provided.\nFacilities for employees must be provided in accordance with F4D4.\nFacilities required by (a), (b) or (c) need not be situated in the same building.\n(3) For facilities in Class 3 residential care buildings, the following applies:\nFor residents in each building or group of buildings, provide—\na shower, closet pan and wash basin for each 8 residents or part thereof where private facilities are not provided; and\na suitable bath for each 30 residents or part thereof.\nFor the purposes of (a), urinals must not be taken into consideration in calculating the number of facilities.\n(4) For facilities in a Class 4 part of a building, the following applies:\nFor the sole-occupancy unit, provide—\na kitchen sink and facilities for the preparation and cooking of food; and\na bath or shower; and\na closet pan; and\na washbasin; and\nclothes washing facilities, comprising a washtub and space in the same room for a washing machine; and\na clothes line or hoist, or space for a heat-operated drying cabinet or similar appliance for the exclusive use of the occupants.\nFor the purposes of (a), a kitchen sink or washbasin must not be counted as a laundry washtub.\n(5) For facilities in Class 9c buildings, the following applies:\nFor residents in each building or group of buildings, provide—\na closet pan and wash basin for each 6 residents or part thereof where private facilities are not provided; and\na shower for each 7 residents or part thereof for where private facilities are not provided; and\na suitable bath, fixed or mobile.\nIn addition to the facilities required by (a), provide—\none kitchen or other adequate facility for the preparation and cooking or reheating of food including a kitchen sink and washbasin; and\nlaundry facilities for the cleansing and drying of linen and clothing or adequate facilities for holding and dispatch or treatment of soiled linen and clothing and the like and the receipt and storage of clean linen; and\none clinical hand washing basin for each 16 residents or part thereof.\nFor the purposes of (a), urinals must not be taken into consideration in calculating the number of facilities.","g":"/ncc/f4d2","a19":["F2.1"]},{"c":"F4D3","t":"Calculation of number of occupants and facilities","p":"Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f4-sanitary-and-other-facilities#F4D3","x":"(1) The number of persons accommodated must be calculated according to D2D18 if it cannot be more accurately determined by other means.\n(2) Unless the premises are used predominantly by one sex, sanitary facilities must be provided on the basis of equal numbers of males and females.\n(3) In calculating the number of sanitary facilities to be provided under F4D2 and F4D4, a unisex facility required for people with a disability (other than a facility provided under F4D12) may be counted once for each sex.\n(4) For the purposes of this Part, a unisex facility comprises one closet pan, one washbasin and means for the disposal of sanitary products.","g":"/ncc/f4d3","a19":["F2.2"]},{"c":"Table F4D4a","t":"Sanitary facilities in Class 3, 5, 6 and 9 buildings other than schools","p":"Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f4-sanitary-and-other-facilities#_1a81ef10-9ea5-4722-957b-c1bbeacc23b5","x":"User group | Facility type | Design occupancy | Number\nMale employees | Closet pans | 1 - 20 | 1\n>20 | Add 1 per 20\nUrinals | 1 - 10 | 0\n11 - 25 | 1\n26 - 50 | 2\n>50 | Add 1 per 50\nWashbasins | 1 - 30 | 1\n>30 | Add 1 per 30\nFemale employees | Closet pans | 1 - 15 | 1\n>15 | Add 1 per 15\nWashbasins | 1 - 30 | 1\n>30 | Add 1 per 30","tb":"F4D4","g":"/ncc/table-f4d4a"},{"c":"Table F4D4b","t":"Sanitary facilities in Class 7 and 8 buildings","p":"Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f4-sanitary-and-other-facilities#_a01f7587-02cc-4dec-9ffa-0f16636ea132","x":"User group | Facility type | Design occupancy | Number\nMale employees | Closet pans | 1 - 20 | 1\n>20 | Add 1 per 20\nUrinals | 1 - 10 | 0\n11 - 25 | 1\n26 - 50 | 2\n>50 | Add 1 per 50\nWashbasins | 1 - 20 | 1\n>20 | Add 1 per 20\nFemale employees | Closet pans | 1 - 15 | 1\n>15 | Add 1 per 15\nWashbasins | 1 - 20 | 1\n>20 | Add 1 per 20\nTable Notes\nSanitary facilities need not be provided for a Class 8 electricity network substation.","tb":"F4D4","g":"/ncc/table-f4d4b"},{"c":"Table F4D4c","t":"Sanitary facilities in Class 6 buildings – department stores, shopping centres","p":"Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f4-sanitary-and-other-facilities#_33e3fae4-0a3f-4909-9ae8-049e29d940a3","x":"User group | Facility type | Design occupancy | Number\nMale patrons | Closet pans | 1 - 1200 | 1\n>1200 | Add 1 per 1200\nUrinals | 1 - 600 | 1\n>600 | Add 1 per 1200\nWashbasins | 1 - 600 | 1\n>600 | Add 1 per 1200\nFemale patrons | Closet pans | 1 - 300 | 1\n301 - 600 | 2\n>600 | Add 1 per 1200\nWashbasins | 1-600 | 1\n601 - 1200 | 2\n>1200 | Add 1 per 1200\nTable Notes\nSanitary facilities need not be provided for patrons if the total number of persons accommodated in the building is not more than 600.","tb":"F4D4","g":"/ncc/table-f4d4c"},{"c":"Table F4D4d","t":"Sanitary facilities in Class 6 buildings – restaurants, cafes, bars","p":"Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f4-sanitary-and-other-facilities#_accc0eca-2288-4364-84d5-4d08d161c3d2","x":"User group | Facility type | Design occupancy | Number\nMale patrons | Closet pans | 1 - 100 | 1\n101 - 300 | 2\n>300 | Add 1 per 200\nUrinals | 1 - 50 | 1\n51 - 100 | 2\n101 - 150 | 3\n151 - 200 | 4\n201 - 250 | 5\n>250 | Add 1 per 100\nWashbasins | 1 - 50 | 1\n51 - 200 | 2\n>200 | Add 1 per 200\nFemale patrons | Closet pans | 1 - 25 | 1\n26 - 50 | 2\n51 - 100 | 3\n101 - 150 | 4\n151 - 200 | 5\n201 - 250 | 6\n>250 | Add 1 per 100\nWashbasins | 1 - 50 | 1\n51 - 150 | 2\n>150 | Add 1 per 200\nTable Notes\nSanitary facilities need not be provided for patrons if the total number of persons accommodated in the building is not more than 20.","tb":"F4D4","g":"/ncc/table-f4d4d"},{"c":"Table F4D4e","t":"Sanitary facilities in Class 9a health-care buildings","p":"Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f4-sanitary-and-other-facilities#_1932e1a8-0fcd-412f-81ce-e5efc514163f","x":"User group | Facility type | Design occupancy | Number\nMale patients | Closet pans | 1 - 16 | 2\n>16 | Add 1 per 8\nWashbasins | 1 - 8 | 1\n>8 | Add 1 per 8\nFemale patients | Closet pans | 1 - 16 | 2\n>16 | Add 1 per 8\nWashbasins | 1 - 8 | 1\n>8 | Add 1 per 8\nTable Notes\nUrinals are not required for a Class 9a health-care building.","tb":"F4D4","g":"/ncc/table-f4d4e"},{"c":"Table F4D4f","t":"Sanitary facilities in Class 9b buildings – schools","p":"Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f4-sanitary-and-other-facilities#_70a82254-35b2-4d04-aa78-c4b60762d111","x":"User group | Facility type | Design occupancy | Number\nMale employees | Closet pans | 1 - 20 | 1\n>20 | Add 1 per 20\nUrinals | 1 - 10 | 0\n11 - 20 | 1\n21 - 45 | 2\n>45 | Add 1 per 30\nWashbasins | 1 -30 | 1\n>30 | Add 1 per 30\nFemale employees | Closet pans | 1 - 5 | 1\n>5 | Add 1 per 15\nWashbasins | 1 - 30 | 1\n>30 | Add 1 per 30\nMale students | Closet pans | 1 - 25 | 1\n26 - 75 | 2\n76 - 150 | 3\n151 - 200 | 4\n>200 | Add 1 per 100\nUrinals | 1 - 50 | 1\n51 - 100 | 2\n>100 | Add 1 per 100\nWashbasins | 1 - 10 | 1\n11 - 50 | 2\n51 - 100 | 3\n>100 | Add 1 per 75\nFemale students | Closet pans | 1 - 10 | 1\n11 - 25 | 2\n26 - 100 | Add 1 per 25\n>100 | Add 1 per 50\nWashbasins | 1 - 10 | 1\n11 - 50 | 2\n51 - 100 | 3\n>100 | Add 1 per 75","tb":"F4D4","g":"/ncc/table-f4d4f"},{"c":"Table F4D4g","t":"Sanitary facilities in Class 9b buildings – early childhood centres","p":"Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f4-sanitary-and-other-facilities#_f28beabc-98b5-4028-94a0-1ca8b222fd2d","x":"User group | Facility type | Design occupancy | Number\nChildren | Closet pans | 1 - 30 | 2\n>30 | Add 1 per 15\nWashbasins | 1 - 30 | 2\n>30 | Add 1 per 15\nTable Notes\nUrinals are not required for a Class 9b early childhood centre.\nFacilities for use by children must be—\njunior pans; and\nwashbasins with a rim height not exceeding 600 mm; and\naccessible from both indoor and outdoor play areas.","tb":"F4D4","g":"/ncc/table-f4d4g"},{"c":"Table F4D4h","t":"Sanitary facilities in Class 9b buildings – theatres and cinemas with multiple auditoria, art galleries and the like","p":"Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f4-sanitary-and-other-facilities#_05fa7420-e74b-4c6b-b075-205e9a7e68e4","x":"User group | Facility type | Design occupancy | Number\nMale participants | Closet pans | 1 - 20 | 1\n>20 | Add 1 per 20\nUrinals | 1 - 10 | 1\n>10 | Add 1 per 10\nWashbasins | 1 - 10 | 1\n>10 | Add 1 per 10\nFemale participants | Closet pans | 1 - 10 | 1\n>10 | Add 1 per 10\nWashbasins | 1 - 10 | 1\n>10 | Add 1 per 10\nMale spectators or patrons | Closet pans | 1 - 250 | 1\n251 - 500 | 2\n>500 | Add 1 per 500\nUrinals | 1 - 100 | 1\n>100 | Add 1 per 100\nWashbasins | 1 - 150 | 1\n>150 | Add 1 per 150\nFemale spectators or patrons | Closet pans | 1 - 10 | 1\n11 - 50 | 2\n>50 | Add 1 per 60\nWashbasins | 1 - 80 | 1\n81 - 250 | 2\n251 - 430 | 3\n>430 | Add 1 per 200","tb":"F4D4","g":"/ncc/table-f4d4h"},{"c":"Table F4D4i","t":"Sanitary facilities in Class 9b buildings – single auditorium theatres and cinemas","p":"Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f4-sanitary-and-other-facilities#_484acf27-f1a9-4548-9eb7-0597b921c873","x":"User group | Facility type | Design occupancy | Number\nMale patrons | Closet pans | 1 - 50 | 0\n51 - 250 | 1\n251 - 500 | 2\n>500 | Add 1 per 500\nUrinals | 1 - 50 | 0\n51 - 100 | 1\n>100 | Add 1 per 100\nWashbasins | 1 - 50 | 0\n51 - 150 | 1\n>150 | Add 1 per 150\nFemale patrons | Closet pans | 1 - 50 | 0\n51 - 75 | 4\n76 - 110 | 5\n111 - 170 | 6\n171 - 230 | 7\n231 - 250 | 9\n>250 | Add 1 per 60\nWashbasins | 1 - 50 | 0\n51 - 150 | 1\n>150 | Add 1 per 150","tb":"F4D4","g":"/ncc/table-f4d4i"},{"c":"Table F4D4j","t":"Sanitary facilities in Class 9b buildings – sports venues or the like","p":"Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f4-sanitary-and-other-facilities#_fe5244ab-3363-4e85-afcb-bfd9afdfa280","x":"User group | Facility type | Design occupancy | Number\nMale participants | Closet pans | 1 - 20 | 1\n>20 | Add 1 per 20\nUrinals | 1 - 10 | 1\n>10 | Add 1 per 10\nWashbasins | 1 - 10 | 1\n>10 | Add 1 per 10\nFemale participants | Closet pans | 1 - 10 | 1\n>10 | Add 1 per 10\nWashbasins | 1 - 10 | 1\n>10 | Add 1 per 10\nMale spectators or patrons | Closet pans | 1 - 250 | 1\n251 - 500 | 2\n>500 | Add 1 per 500\nUrinals | 1 - 100 | 1\n>100 | Add 1 per 100\nWashbasins | 1 - 150 | 1\n>150 | Add 1 per 150\nFemale spectators or patrons | Closet pans | 1 - 15 | 1\n16 - 60 | 2\n61 - 120 | 3\n>120 | Add 1 per 70\nWashbasins | 1 - 60 | 1\n61 - 200 | 2\n201 - 350 | 3\n>350 | Add 1 per 150","tb":"F4D4","g":"/ncc/table-f4d4j"},{"c":"Table F4D4k","t":"Sanitary facilities in Class 9b buildings – churches, chapels or the like","p":"Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f4-sanitary-and-other-facilities#_83986f7f-937e-42c2-bc89-fb35de2cd9bd","x":"User group | Facility type | Design occupancy | Number\nMale patrons | Closet pans | 1 - 300 | 1\n>300 | Add 1 per 500\nUrinals | 1 - 200 | 1\n>200 | Add 1 per 200\nWashbasins | 1 - 250 | 1\n>250 | Add 1 per 250\nFemale patrons | Closet pans | 1 - 150 | 1\n>150 | Add 1 per 150\nWashbasins | 1 - 250 | 1\n>250 | Add 1 per 250","tb":"F4D4","g":"/ncc/table-f4d4k"},{"c":"Table F4D4l","t":"Sanitary facilities in Class 9b buildings – public halls, function rooms or the like","p":"Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f4-sanitary-and-other-facilities#_413df910-5000-4a6b-bd15-1781f09cc92c","x":"User group | Facility type | Design occupancy | Number\nMale patrons | Closet pans | 1 - 100 | 1\n>100 | Add 1 per 200\nUrinals | 1 - 50 | 1\n51 - 100 | 2\n101 - 150 | 3\n151 - 200 | 4\n201 - 250 | 5\n>250 | Add 1 per 100\nWashbasins | 1 - 50 | 1\n51 - 200 | 2\n>200 | Add 1 per 200\nFemale patrons | Closet pans | 1 - 25 | 1\n26 - 50 | 2\n51 - 100 | 3\n101 - 150 | 4\n151 - 200 | 5\n201 - 250 | 6\n>250 | Add 1 per 100\nWashbasins | 1 - 50 | 1\n51 - 150 | 2\n>150 | Add 1 per 200\nTable Notes\nSanitary facilities need not be provided for patrons if the total number of persons accommodated in the building is not more than 20.","tb":"F4D4","g":"/ncc/table-f4d4l"},{"c":"F4D4","t":"Facilities in Class 3 to 9 buildings","p":"Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f4-sanitary-and-other-facilities#F4D4","x":"(1) Except where permitted by (3), (4), (7), (12), F4D5(a), F4D5(b) and F4D12(1), separate sanitary facilities for males and females must be provided for Class 3, 5, 6, 7, 8 or 9 buildings in accordance with Tables F4D4a, F4D4b, F4D4c, F4D4d, F4D4e, F4D4f, F4D4g, F4D4h, F4D4i, F4D4j, F4D4k and F4D4l, as appropriate.\n(2) In Tables F4D4a, F4D4b, F4D4c, F4D4d, F4D4e, F4D4f, F4D4g, F4D4h, F4D4i, F4D4j, F4D4k and F4D4l —\n‘Number’ means the number of facilities required; and\n‘>’ means greater than; and\na hyphen means no data (refer to the row above for the highest value applicable); and\n‘N/A’ means not applicable; and\na reference to—\n‘employees’ includes owners and managers using the building; and\n‘add 1 per 100 or 150, 250, 500, etc.’ includes any part thereof of that number.\n(3) If not more than 10 people are employed, a unisex facility may be provided instead of separate facilities for each sex.\n(4) If the majority of employees are of one sex, not more than 2 employees of the other sex may share toilet facilities if the facilities are separated by means of walls, partitions and doors to afford privacy.\n(5) Employees and the public may share the same facilities in a Class 6 and 9b building (other than a school or early childhood centre) provided the number of facilities provided is not less than the total number of facilities required for employees plus those required for the public.\n(6) Sanitary facilities must comply with the following:\nIn all sanitary facilities, adequate means of disposal of sanitary products must be provided.\nIn sanitary facilities for use by females, a dispenser for sanitary products must be provided.\n(7) Separate sanitary facilities for males and females need not be provided for patients in a ward area of a Class 9a building.\n(8) A Class 9a health-care building must be provided with—\none kitchen or other adequate facility for the preparation and cooking or reheating of food including a kitchen sink and washbasin; and\nlaundry facilities for the cleansing and drying of linen and clothing or adequate facilities for holding and dispatch or treatment of soiled linen and clothing, sanitary products and the like and the receipt and storage of clean linen; and\none shower for each 8 patients or part thereof; and\none island-type plunge bath in each storey containing a ward area.\n(9) A Class 9b early childhood centre must be provided with—\na kitchen or food preparation area with a kitchen sink, separate hand washing facilities, space for a refrigerator and space for cooking facilities, with—\nthe facilities protected by a door or gate with child proof latches to prevent unsupervised access to the facilities by children younger than 5 years old; and\nthe ability to facilitate supervision of children from the facilities if the early childhood centre accommodates children younger than 2 years old; and\none bath, shower or shower-bath; and\nif the centre accommodates children younger than 3 years old—\na laundry facility comprising a washtub and space in the same room for a washing machine; and\na bench type baby bath, which is within 1 m of the nappy change bench; and\na nappy changing bench which—\nis within 1 m of separate adult hand washing facilities and bench type baby bath; and\nmust be not less than 0.9 m2 in area and at a height of not less than 850 mm, but not more than 900 mm above the finished floor level; and\nmust have a space not less than 800 mm high, 500 mm wide and 800 mm deep for the storage of steps; and\nis positioned to permit a staff member changing a nappy to have visibility of the play area at all times.\n(10) Class 9b theatres and sporting venues must be provided with one shower for each 10 participants or part thereof.\n(11) Not less than one washbasin must be provided where closet pans or urinals are provided.\n(12) All gender sanitary facilities may be provided in lieu of sanitary facilities for males and females provided in accordance with (1) in accordance with the following:\nWhere (1) requires in total 1 closet pan for males and 1 closet pan for females — all required closet pans and washbasins may be provided in all gender facilities.\nWhere (1) requires in total 3 closet pans or urinals — 1 closet pan may be provided in an all-gender facility where 1 closet pan is provided for use by males and 1 closet pan is provided for use by females.\nWhere (1) requires in total 4 or more closet pans or urinals — up to half of required closet pans or urinals for use by males and up to half of required closet pans for use by females may be provided in all gender facilities where the proportion of facilities deducted from males and the proportion of facilities deducted from females is equal.\nWhere (c) is applied, the number of washbasins required by (1) for use by males and females may be reduced by the proportion applied to closet pans and urinals\n(13) For the purposes of this part, an all gender sanitary facility comprises 1 closet pan and 1 washbasin within the same compartment.\n(14) An all gender sanitary facility must—\nbe located so that it can be entered without crossing an area reserved for one sex only; and\nbe identified by signage that states “all gender”.\nTable F4D4a Sanitary facilities in Class 3, 5, 6 and 9 buildings other than schools\nUser group\nFacility type\nDesign occupancy\nNumber\nMale employees\nCloset pans\n1 - 20\n1\n>20\nAdd 1 per 20\nUrinals\n1 - 10\n0\n11 - 25\n1\n26 - 50\n2\n>50\nAdd 1 per 50\nWashbasins\n1 - 30\n1\n>30\nAdd 1 per 30\nFemale employees\nCloset pans\n1 - 15\n1\n>15\nAdd 1 per 15\nWashbasins\n1 - 30\n1\n>30\nAdd 1 per 30\nTable F4D4b Sanitary facilities in Class 7 and 8 buildings\nUser group\nFacility type\nDesign occupancy\nNumber\nMale employees\nCloset pans\n1 - 20\n1\n>20\nAdd 1 per 20\nUrinals\n1 - 10\n0\n11 - 25\n1\n26 - 50\n2\n>50\nAdd 1 per 50\nWashbasins\n1 - 20\n1\n>20\nAdd 1 per 20\nFemale employees\nCloset pans\n1 - 15\n1\n>15\nAdd 1 per 15\nWashbasins\n1 - 20\n1\n>20\nAdd 1 per 20\nTable Notes\nSanitary facilities need not be provided for a Class 8 electricity network substation.\nTable F4D4c Sanitary facilities in Class 6 buildings – department stores, shopping centres\nUser group\nFacility type\nDesign occupancy\nNumber\nMale patrons\nCloset pans\n1 - 1200\n1\n>1200\nAdd 1 per 1200\nUrinals\n1 - 600\n1\n>600\nAdd 1 per 1200\nWashbasins\n1 - 600\n1\n>600\nAdd 1 per 1200\nFemale patrons\nCloset pans\n1 - 300\n1\n301 - 600\n2\n>600\nAdd 1 per 1200\nWashbasins\n1-600\n1\n601 - 1200\n2\n>1200\nAdd 1 per 1200\nTable Notes\nSanitary facilities need not be provided for patrons if the total number of persons accommodated in the building is not more than 600.\nTable F4D4d Sanitary facilities in Class 6 buildings – restaurants, cafes, bars\nUser group\nFacility type\nDesign occupancy\nNumber\nMale patrons\nCloset pans\n1 - 100\n1\n101 - 300\n2\n>300\nAdd 1 per 200\nUrinals\n1 - 50\n1\n51 - 100\n2\n101 - 150\n3\n151 - 200\n4\n201 - 250\n5\n>250\nAdd 1 per 100\nWashbasins\n1 - 50\n1\n51 - 200\n2\n>200\nAdd 1 per 200\nFemale patrons\nCloset pans\n1 - 25\n1\n26 - 50\n2\n51 - 100\n3\n101 - 150\n4\n151 - 200\n5\n201 - 250\n6\n>250\nAdd 1 per 100\nWashbasins\n1 - 50\n1\n51 - 150\n2\n>150\nAdd 1 per 200\nTable Notes\nSanitary facilities need not be provided for patrons if the total number of persons accommodated in the building is not more than 20.\nTable F4D4e Sanitary facilities in Class 9a health-care buildings\nUser group\nFacility type\nDesign occupancy\nNumber\nMale patients\nCloset pans\n1 - 16\n2\n>16\nAdd 1 per 8\nWashbasins\n1 - 8\n1\n>8\nAdd 1 per 8\nFemale patients\nCloset pans\n1 - 16\n2\n>16\nAdd 1 per 8\nWashbasins\n1 - 8\n1\n>8\nAdd 1 per 8\nTable Notes\nUrinals are not required for a Class 9a health-care building.\nTable F4D4f Sanitary facilities in Class 9b buildings – schools\nUser group\nFacility type\nDesign occupancy\nNumber\nMale employees\nCloset pans\n1 - 20\n1\n>20\nAdd 1 per 20\nUrinals\n1 - 10\n0\n11 - 20\n1\n21 - 45\n2\n>45\nAdd 1 per 30\nWashbasins\n1 -30\n1\n>30\nAdd 1 per 30\nFemale employees\nCloset pans\n1 - 5\n1\n>5\nAdd 1 per 15\nWashbasins\n1 - 30\n1\n>30\nAdd 1 per 30\nMale students\nCloset pans\n1 - 25\n1\n26 - 75\n2\n76 - 150\n3\n151 - 200\n4\n>200\nAdd 1 per 100\nUrinals\n1 - 50\n1\n51 - 100\n2\n>100\nAdd 1 per ","g":"/ncc/f4d4","a19":["F2.3"]},{"c":"F4D5","t":"Accessible sanitary facilities","p":"Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f4-sanitary-and-other-facilities#F4D5","x":"In a building required to be accessible —\naccessible unisex sanitary compartments must be provided in accessible parts of the building in accordance with F4D6; and\naccessible unisex showers must be provided in accordance with F4D7; and\nat each bank of toilets where there is one or more toilets in addition to an accessible unisex sanitary compartment at that bank of toilets, not less than one sanitary compartment suitable for a person with an ambulant disability for use by males and not less than one sanitary compartment suitable for a person with an ambulant disability for use by females, each in accordance with AS 1428.1, must be provided; and\nan accessible unisex sanitary compartment must contain a closet pan, washbasin, shelf or bench top and adequate means of disposal of sanitary products; and\nthe circulation spaces, fixtures and fittings of all accessible sanitary facilities provided in accordance with F4D6 and F4D7 must comply with the requirements of AS 1428.1; and\nan accessible unisex sanitary facility must be located so that it can be entered without crossing an area reserved for one sex only; and\nwhere two or more of each type of accessible unisex sanitary facility are provided, the number of left and right handed mirror image facilities must be provided as evenly as possible; and\nwhere male sanitary facilities are provided at a separate location to female sanitary facilities, accessible unisex sanitary facilities are only required at one of those locations; and\nan accessible unisex sanitary compartment or an accessible unisex shower need not be provided on a storey or level that is not required by D4D4(f) to be provided with a passenger lift or ramp complying with AS 1428.1.","g":"/ncc/f4d5","a19":["F2.4"]},{"c":"F4D6","t":"Accessible unisex sanitary compartments","p":"Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f4-sanitary-and-other-facilities#F4D6","x":"(1) Where required by F4D5(a), the minimum number of accessible unisex sanitary compartments for each class of building is as follows:\nFor a Class 1b building—\nnot less than 1; and\nwhere private accessible unisex sanitary compartments are provided for every accessible bedroom, common accessible unisex sanitary compartments need not be provided.\nFor a Class 2 building, where sanitary compartments are provided in common areas, not less than 1.\nFor Class 3 and Class 9c buildings—\nin every accessible sole-occupancy unit provided with sanitary compartments within the accessible sole-occupancy unit, not less than 1; and\nat each bank of sanitary compartments provided in common areas containing 2 or more sanitary compartments, not less than 1.\nFor Class 5, 6, 7, 8 or 9 buildings, where F4D4 requires closet pans—\n1 on every storey containing sanitary compartments; and\nwhere a storey has more than 1 bank of sanitary compartments containing male and female sanitary compartments, at not less than 50% of those banks.\nFor a Class 10a building, at each bank of sanitary compartments containing 2 or more sanitary compartments, not less than 1.\n(2) The requirements of (1)(d) do not apply within a ward area of a Class 9a health-care building.\n(3) The requirements of (1)(e) do not apply to—\na Class 10a appurtenant to another class of building; or\na sanitary compartment dedicated to a single caravan/camping site.","g":"/ncc/f4d6","a19":["Table F2.4a"]},{"c":"F4D7","t":"Accessible unisex showers","p":"Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f4-sanitary-and-other-facilities#F4D7","x":"(1) Where required by F4D5(b), the minimum number of accessible unisex showers for each class of building is as follows:\nFor a Class 1b building—\nnot less than 1; and\nwhere private accessible unisex showers are provided for every accessible bedroom, common accessible unisex showers need not be provided.\nFor a Class 2 building, where showers are provided in common areas, not less than 1.\nFor Class 3 and 9c buildings—\nin every accessible sole-occupancy unit provided with showers within the accessible sole-occupancy unit, not less than 1; and\n1 for every 10 showers or part thereof provided in common areas.\nFor Class 5, 6, 7, 8 or 9 buildings, where F4D4 requires 1 or more showers, not less than 1 for every 10 showers or part thereof.\nFor a Class 10a building, where showers are provided, 1 for every 10 showers or part thereof.\n(2) The requirements of (1)(d) do not apply within a ward area of a Class 9a health-care building.\n(3) The requirements of (1)(e) do not apply to—\na Class 10a appurtenant to another class of building; and\na sanitary compartment dedicated to a single caravan/camping site.","g":"/ncc/f4d7","a19":["Table F2.4b"]},{"c":"F4D8","t":"Construction of sanitary compartments","p":"Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f4-sanitary-and-other-facilities#F4D8","x":"(1) Other than in an early childhood centre, sanitary compartments must have doors and partitions that separate adjacent compartments and extend—\nfrom floor level to the ceiling in the case of a unisex facility or all gender facility; or\nto a height of not less than 1.5 m above the floor if primary school children are the principal users; or\n1.8 m above the floor in all other cases.\n(2) Unless there is a clear space of at least 1.2 m, measured in accordance with Figure F4D8, between the closet pan within the sanitary compartment and the doorway, the door to a fully enclosed sanitary compartment must—\nopen outwards; or\nslide; or\nbe readily removable from the outside of the sanitary compartment.\n(3) In an early childhood centre, facilities for use by children must have each sanitary compartment screened by a partition which, except for the doorway, is opaque for a height of at least 900 mm but not more than 1200 mm above the floor level.\nFigure F4D8 Construction of sanitary compartments","g":"/ncc/f4d8","a19":["F2.5"]},{"c":"F4D9","t":"Interpretation: urinals and washbasins","p":"Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f4-sanitary-and-other-facilities#F4D9","x":"(1) A urinal may be—\nan individual stall or wall-hung urinal; or\neach 600 mm length of a continuous urinal trough; or\na closet pan used in place of a urinal.\n(2) A washbasin may be—\nan individual basin; or\na part of a hand washing trough served by a single water tap.","g":"/ncc/f4d9","a19":["F2.6"]},{"c":"F4D10","t":"Microbial (legionella) control","p":"Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f4-sanitary-and-other-facilities#F4D10","x":"Hot water, warm water and cooling water systems in a building other than a system serving only a single sole-occupancy unit in a Class 2 or 3 building or Class 4 part of a building must be installed in accordance with AS/NZS 3666.1.","g":"/ncc/f4d10","a19":["F2.7"]},{"c":"F4D11","t":"Waste management","p":"Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f4-sanitary-and-other-facilities#F4D11","x":"(1) In a Class 9a health-care building, at least one slop-hopper or other device, other than a water closet pan or urinal, must be provided—\non any storey containing ward areas or bedrooms to facilitate emptying of containers of sewage or dirty water; and\nwith a flushing apparatus, tap and grating.\n(2) In a Class 9c building, the following facilities must be provided for every 60 beds or part thereof on each storey containing resident use areas:\nOne slop-hopper or other device other than a water closet pan or urinal for the safe handling and disposal of liquid and solid wastes with a flushing apparatus, tap and grating.\nAn appliance for the disinfection of pans or an adequate means to dispose of receptacles.","g":"/ncc/f4d11","a19":["F2.8"]},{"c":"F4D12","t":"Accessible adult change facilities","p":"Part F4 Sanitary and other facilities","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f4-sanitary-and-other-facilities#F4D12","x":"(1) One unisex accessible adult change facility must be provided in an accessible part of a—\nClass 6 building that is a shopping centre having a design occupancy of not less than 3,500 people, calculated on the basis of the floor area and containing a minimum of 2 sole-occupancy units; and\nClass 9b sports venue or the like that—\nhas a design occupancy of not less than 35,000 spectators; or\ncontains a swimming pool that has a perimeter of not less than 70 m and that is required by D4D2 to be accessible; and\nmuseum, art gallery or the like having a design occupancy of not less than 1,500 patrons; and\ntheatre or the like having a design occupancy of not less than 1,500 patrons; and\npassenger use area of an airport terminal building within an airport that accepts domestic and/or international flights that are public transport services as defined in the Disability Standards for Accessible Public Transport 2002.\n(2) Accessible adult change facilities required by (1)—\nmust be constructed in accordance with Specification 27; and\ncannot be combined with another sanitary compartment.\n(3) For the purposes of (1), design occupancy must be calculated in accordance with D2D18, but excluding any area that—\ncan only be accessed by staff, employees, contractors, maintenance personnel and the like; or\nis subject to an exemption under D4D5.","g":"/ncc/f4d12","a19":["F2.9"]},{"c":"F5O1","t":"Objective","p":"Part F5 Room heights","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f5-room-heights#F5O1","x":"The Objective of this Part is to safeguard occupants from injury or loss of amenity caused by inadequate height of a room or space.","g":"/ncc/f5o1","a19":["FO3"]},{"c":"F5F1","t":"Room or space heights","p":"Part F5 Room heights","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f5-room-heights#F5F1","x":"A building is to be constructed to provide height in a room or space suitable for the intended use.","g":"/ncc/f5f1","a19":["FF3.1"]},{"c":"F5P1","t":"Room or space heights","p":"Part F5 Room heights","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f5-room-heights#F5P1","x":"A habitable room or space must have sufficient height that does not unduly interfere with its intended function.","g":"/ncc/f5p1","a19":["VIC FP3.1","FP3.1"]},{"c":"F5V1","t":"Room or space heights","p":"Part F5 Room heights","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f5-room-heights#F5V1","x":"(1) Compliance with F5P1 is verified where the height of a habitable room or space provides an appropriate activity support level that does not unduly interfere with its intended function.\n(2) For the purposes of (1), the activity support level must consider the dimensions of—\ndoors, required exits, ramps, barriers, stairs and windows; and\nfixed fittings and services; and\nfixed and moveable equipment or furniture; and\noccupant circulation spaces.","g":"/ncc/f5v1","a19":["FV3.1"]},{"c":"F5D1","t":"Deemed-to-Satisfy Provisions","p":"Part F5 Room heights","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f5-room-heights#F5D1","x":"(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirement F5P1 is satisfied by complying with—\nF5D2; and\nfor farm sheds, Part I3.\n(2) Where a Performance Solution is proposed, the relevant Performance Requirements must be determined in accordance with A2G2(3) and A2G4(3) as applicable.","g":"/ncc/f5d1","a19":["VIC F3.0","F3.0"]},{"c":"F5D2","t":"Height of rooms and other spaces","p":"Part F5 Room heights","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f5-room-heights#F5D2","x":"(1) The height of rooms and other spaces in a Class 2 or 3 building or Class 4 part of a building must be not less than—\nfor a kitchen, laundry, or the like — 2.1 m; and\nfor a corridor, passageway or the like — 2.1 m; and\nfor a habitable room excluding a kitchen — 2.4 m; and\nin a habitable room, or space within a habitable room, with a sloping ceiling or projections below the ceiling line—\nin an attic — a height of not less than 2.2 m for not less than two-thirds of the floor area of the room or space; and\nin other rooms — a height of not less than 2.4 m for not less than two-thirds of the floor area of the room or space; and\nin a non-habitable room, or space within a non-habitable room, with a sloping ceiling or projections below the ceiling line — a height of not less than 2.1 m for not less than two-thirds of the floor area of the room or space.\n(2) For the purposes of (1), when calculating the floor area of a room or space, any part that has a ceiling height of less than 1.5 m is not included.\n(3) The height of rooms and other spaces in a Class 5, 6, 7 or 8 building must be not less than—\nexcept as allowed in (b) and (8) — 2.4 m; and\nfor a corridor, passageway, or the like — 2.1 m.\n(4) The height of rooms and other spaces in a Class 9a health-care building must be not less than—\nfor a patient care area — 2.4 m; and\nfor an operating theatre or delivery room — 3 m; and\nfor a treatment room, clinic, waiting room, passageway, corridor, or the like — 2.4 m.\n(5) The height of rooms and other spaces in a Class 9b building must be not be less than—\nfor a school classroom or other assembly building or part that accommodates not more than 100 persons — 2.4 m; and\nfor a theatre, public hall or other assembly building or part that accommodates more than 100 persons — 2.7 m; and\nfor a corridor—\nthat serves an assembly building or part that accommodates not more than 100 persons — 2.4 m; or\nthat serves an assembly building or part that accommodates more than 100 persons — 2.7 m.\n(6) For the purposes of (5) the number of persons accommodated must be calculated according to D2D18.\n(7) The height of rooms and other spaces in a Class 9c building must be not be less than—\nfor a kitchen, laundry, or the like — 2.1 m; and\nfor a corridor, passageway or the like — 2.4 m; and\nfor a habitable room excluding a kitchen — 2.4 m.\n(8) The height of rooms and other spaces in any building must be not be less than—\nfor a bathroom, shower room, sanitary compartment, other than an accessible adult change facility, airlock, tea preparation room, pantry, store room, garage, car parking area, or the like — 2.1 m; and\nfor a commercial kitchen — 2.4 m; and\nabove a stairway, ramp (other than a threshold ramp), landing or the like — 2 m measured vertically above the nosing line of stairway treads or the floor surface of the ramp, landing or the like; and\nfor a required accessible adult change facility — 2.4 m.","g":"/ncc/f5d2","a19":["F3.1"]},{"c":"F6O1","t":"Objective","p":"Part F6 Light and ventilation","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f6-light-and-ventilation#F6O1","x":"The Objective of this Part is to—\nsafeguard occupants from injury, illness or loss of amenity due to—\nisolation from natural light; and\nlack of adequate artificial lighting; and\nsafeguard occupants from illness or loss of amenity due to lack of air freshness.","g":"/ncc/f6o1","a19":["FO4"]},{"c":"F6F1","t":"Natural light","p":"Part F6 Light and ventilation","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f6-light-and-ventilation#F6F1","x":"A space within a building used by occupants is to be provided with openings to admit natural light consistent with its function or use.","g":"/ncc/f6f1","a19":["FF4.1"]},{"c":"F6F2","t":"Artificial light","p":"Part F6 Light and ventilation","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f6-light-and-ventilation#F6F2","x":"A space within a building used by occupants is to be provided with artificial lighting consistent with its function or use which, when activated in the absence of suitable natural light, will enable safe movement.","g":"/ncc/f6f2","a19":["FF4.2"]},{"c":"F6F3","t":"Ventilation","p":"Part F6 Light and ventilation","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f6-light-and-ventilation#F6F3","x":"A space used by occupants within a building is to be provided with adequate ventilation consistent with its function or use.","g":"/ncc/f6f3","a19":["FF4.3"]},{"c":"F6P1","t":"Natural lighting","p":"Part F6 Light and ventilation","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f6-light-and-ventilation#F6P1","x":"Sufficient openings must be provided and distributed in a building, appropriate to the function or use of that part of the building so that natural light, when available, provides an average daylight factor of not less than 2%.\nApplications\nF6P1 only applies to a Class 2, 3 or 9 building, or a Class 4 part of a building.","g":"/ncc/f6p1","a19":["FP4.1"]},{"c":"F6P2","t":"Artificial lighting","p":"Part F6 Light and ventilation","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f6-light-and-ventilation#F6P2","x":"Artificial lighting must be installed to provide an illuminance of not less than 20 lux appropriate to the function or use of the building to enable safe movement by occupants.","g":"/ncc/f6p2","a19":["FP4.2"]},{"c":"F6P3","t":"Outdoor air supply","p":"Part F6 Light and ventilation","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f6-light-and-ventilation#F6P3","x":"A space in a building used by occupants must be provided with means of ventilation with outdoor air which will maintain adequate air quality.","g":"/ncc/f6p3","a19":["FP4.3"]},{"c":"F6P4","t":"Mechanical ventilation to control odours and contaminants","p":"Part F6 Light and ventilation","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f6-light-and-ventilation#F6P4","x":"A mechanical air-handling system installed in a building must control—\nthe circulation of objectionable odours; and\nthe accumulation of harmful contamination by micro-organisms, pathogens and toxins.","g":"/ncc/f6p4","a19":["FP4.4"]},{"c":"F6P5","t":"Disposal of contaminated air","p":"Part F6 Light and ventilation","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f6-light-and-ventilation#F6P5","x":"Contaminated air must be disposed of in a manner which does not unduly create a nuisance or hazard to people in the building or other property.","g":"/ncc/f6p5","a19":["FP4.5"]},{"c":"Table F6V1","t":"Maximum contaminant limits for acceptable indoor air quality","p":"Part F6 Light and ventilation","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f6-light-and-ventilation#_9e27c58a-1917-41fd-9afd-5fea78ba1d2c","x":"Pollutant | Averaging time | Maximum air quality value\nCarbon dioxide, CO2 | 8 hours | 850 ppm Note 1\nCarbon monoxide, CO | 15 minutes | 90 ppm\nCarbon monoxide, CO | 30 minutes | 50 ppm\nCarbon monoxide, CO | 1 hour | 25 ppm\nCarbon monoxide, CO | 8 hours | 10 ppm\nFormaldehyde, CH2O | 30 minutes | 0.1 mg/m3\nNitrogen dioxide, NO2 | 1 year | 40 μg/m3 (0.0197 ppm) Note 2\nNitrogen dioxide, NO2 | 1 hour | 200 μg/m3 (0.0987 ppm)\nOzone, O3 | 8 hour, daily maximum | 100 μg/m3 (0.0473 ppm)\nParticulate matter, PM2.5 | 1 year | 10 μg/m3\nParticulate matter, PM2.5 | 24 hour (99th percentile) | 25 μg/m3\nParticulate matter, PM10 | 1 year | 20 μg/m3\nParticulate matter, PM10 | 24 hour (99th percentile) | 50 μg/m3\nTotal volatile organic compounds | 1 hour | 500 μg/m3\nTable Notes\nBased on body odour metric (i.e. 450 ppm above ambient CO2 level of 400 ppm and demand control ventilation provisions in AS 1668.2).\nBased on pressure of 101.325 kPa and temperature of 25°C (i.e. the conversion is mg/m3 = ppm (molecular weight/24.4)).","tb":"F6V1","g":"/ncc/table-f6v1"},{"c":"F6V1","t":"Verification of suitable indoor air quality","p":"Part F6 Light and ventilation","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f6-light-and-ventilation#F6V1","x":"For a Class 2, 3, 5, 6, 9b or 9c building or Class 4 part of a building, compliance with F6P3 and F6P4(a) is verified when it is determined that the building under typical conditions in use is provided with sufficient ventilation with outdoor air such that contaminant levels do not exceed the limits specified in Table F6V1.\nTable F6V1 Maximum contaminant limits for acceptable indoor air quality\nPollutant\nAveraging time\nMaximum air quality value\nCarbon dioxide, CO2\n8 hours\n850 ppm Note 1\nCarbon monoxide, CO\n15 minutes\n90 ppm\nCarbon monoxide, CO\n30 minutes\n50 ppm\nCarbon monoxide, CO\n1 hour\n25 ppm\nCarbon monoxide, CO\n8 hours\n10 ppm\nFormaldehyde, CH2O\n30 minutes\n0.1 mg/m3\nNitrogen dioxide, NO2\n1 year\n40 μg/m3 (0.0197 ppm) Note 2\nNitrogen dioxide, NO2\n1 hour\n200 μg/m3 (0.0987 ppm)\nOzone, O3\n8 hour, daily maximum\n100 μg/m3 (0.0473 ppm)\nParticulate matter, PM2.5\n1 year\n10 μg/m3\nParticulate matter, PM2.5\n24 hour (99th percentile)\n25 μg/m3\nParticulate matter, PM10\n1 year\n20 μg/m3\nParticulate matter, PM10\n24 hour (99th percentile)\n50 μg/m3\nTotal volatile organic compounds\n1 hour\n500 μg/m3\nTable Notes\nBased on body odour metric (i.e. 450 ppm above ambient CO2 level of 400 ppm and demand control ventilation provisions in AS 1668.2).\nBased on pressure of 101.325 kPa and temperature of 25°C (i.e. the conversion is mg/m3 = ppm (molecular weight/24.4)).","g":"/ncc/f6v1","a19":["FV4.1"]},{"c":"Table F6V2","t":"Maximum carbon monoxide exposure for carparks","p":"Part F6 Light and ventilation","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f6-light-and-ventilation#_56d7dd23-bd8d-49dd-8166-2ded6b3e42e1","x":"Concentration (ppm) | Total exposure duration per day\n100 | Not to be exceeded\n90 | 15 minutes\n60 | 1 hour\n30 | 8 hours\nTable Notes\nVarious government work health and safety regulations specify workplace exposure limits for airborne contaminants in the workplace.","tb":"F6V2","g":"/ncc/table-f6v2"},{"c":"F6V2","t":"Verification of suitable indoor air quality for carparks","p":"Part F6 Light and ventilation","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f6-light-and-ventilation#F6V2","x":"For a Class 7a building, compliance with F6P3 and F6P4(a) is verified when it is determined that the building is provided with sufficient ventilation with outdoor air such that carbon monoxide exposure levels do not exceed the limits specified in Table F6V2.\nTable F6V2 Maximum carbon monoxide exposure for carparks\nConcentration (ppm)\nTotal exposure duration per day\n100\nNot to be exceeded\n90\n15 minutes\n60\n1 hour\n30\n8 hours\nTable Notes\nVarious government work health and safety regulations specify workplace exposure limits for airborne contaminants in the workplace.","g":"/ncc/f6v2","a19":["FV4.2"]},{"c":"F6V3","t":"Verification of suitable provision of natural light","p":"Part F6 Light and ventilation","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f6-light-and-ventilation#F6V3","x":"Compliance with F6P1 is verified for the provision of natural light when the average daylight factor for each window is determined in accordance with the formula: [formula] , where—\n[formula] = the net area of the light transmitting window (m2); and\n[formula] = the total area of the internal wall, floor and ceiling surfaces (m2); and\n[formula] = the diffuse light transmittance of the window; and\n[formula] = visible sky angle in degrees, measured in a vertical plane normal to and from the centre of the window; and\n[formula] = the area-weighted average reflectance of area [formula] .\nApplications\nF6V3 only applies to—\nhabitable rooms of Class 2 buildings and Class 4 parts of buildings; and\nbedrooms and dormitories of Class 3 buildings; and\nrooms used for sleeping purposes in Class 9a and 9c buildings; and\ngeneral purpose classrooms in primary and secondary school and playrooms or the like for the use of children in an early childhood centre in Class 9b buildings.","g":"/ncc/f6v3","a19":["FV4.3"]},{"c":"F6D1","t":"Deemed-to-Satisfy Provisions","p":"Part F6 Light and ventilation","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f6-light-and-ventilation#F6D1","x":"(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements F6P1 to F6P5 are satisfied by complying with—\nF6D2 to F6D12; and\nfor a building containing an occupiable outdoor area, Part G6; and\nfor farm buildings and farm sheds, Part I3.\n(2) Where a Performance Solution is proposed, the relevant Performance Requirements must be determined in accordance with A2G2(3) and A2G4(3) as applicable.","g":"/ncc/f6d1","a19":["F4.0"]},{"c":"F6D2","t":"Provision of natural light","p":"Part F6 Light and ventilation","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f6-light-and-ventilation#F6D2","x":"Natural light must be provided in:\nA Class 2 building and a Class 4 part of a building — to all habitable rooms.\nA Class 3 building — to all bedrooms and dormitories.\nClass 9a and 9c buildings — to all rooms used for sleeping purposes.\nA Class 9b building — to all general purpose classrooms in primary or secondary schools and all playrooms or the like for the use of children in an early childhood centre.","g":"/ncc/f6d2","a19":["F4.1"]},{"c":"F6D3","t":"Methods and extent of natural light","p":"Part F6 Light and ventilation","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f6-light-and-ventilation#F6D3","x":"(1) Required natural light must be provided by—\nwindows, excluding roof lights, that—\nhave an aggregate light transmitting area measured exclusive of framing members, glazing bars or other obstructions of not less than 10% of the floor area of the room; and\nare open to the sky or face a court or other space open to the sky or an open verandah, carport or the like; or\nroof lights, that—\nhave an aggregate light transmitting area measured exclusive of framing members, glazing bars or other obstructions of not less than 3% of the floor area of the room; and\nare open to the sky; or\na proportional combination of windows and roof lights required by (a) and (b).\n(2) Except in a Class 9c aged care building, in a Class 2, 3 or 9 building or Class 4 part of a building, a required window that faces a boundary of an adjoining allotment or a wall of the same building or another building on the allotment must not be less than a horizontal distance from that boundary or wall that is the greater of—\ngenerally — 1 m; and\nin a patient care area or other room used for sleeping purposes in a Class 9a building — 3 m; and\n50% of the square root of the exterior height of the wall in which the window is located, measured in metres from its sill.\n(3) In a Class 9c aged care building, a required window must be transparent and located—\nin an external wall with the window sill not more than 1 m above the floor level; and\nwhere the window faces an adjoining allotment, another building or another wall of the same building, it must not be less than a horizontal distance of 3 m from the adjoining allotment, other building or wall.\n(4) In a Class 9b early childhood centre, the sills of 50% of windows in children's rooms must be located not more than 500 mm above the floor level.","g":"/ncc/f6d3","a19":["F4.2"]},{"c":"F6D4","t":"Natural light borrowed from adjoining room","p":"Part F6 Light and ventilation","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f6-light-and-ventilation#F6D4","x":"(1) Natural light to a room in a Class 2 building or Class 4 part of a building or in a sole-occupancy unit of a Class 3 building, may come through one or more glazed panels or openings from an adjoining room (including an enclosed verandah) if—\nboth rooms are within the same sole-occupancy unit or the enclosed verandah is on common property; and\nthe glazed panels or openings have an aggregate light transmitting area of not less than 10% of the floor area of the room to which it provides light; and\nthe adjoining room has—\nwindows, excluding roof lights, that—\nhave an aggregate light transmitting area of not less than 10% of the combined floor areas of both rooms; and\nare open to the sky or face a court or other space open to the sky or an open verandah, carport or the like; or\nroof lights, that—\nhave an aggregate light transmitting area of not less than 3% of the combined floor areas of both rooms; and\nare open to the sky; or\na proportional combination of windows and roof lights required by (i) and (ii).\n(2) The areas specified in (1)(b) and (c) may be reduced as appropriate if direct natural light is provided from another source.","g":"/ncc/f6d4","a19":["F4.3"]},{"c":"F6D5","t":"Artificial lighting","p":"Part F6 Light and ventilation","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f6-light-and-ventilation#F6D5","x":"(1) Artificial lighting must be provided—\nin required stairways, passageways, and ramps; and\nif natural light of a standard equivalent to that required by F6D3 is not available, and the periods of occupation or use of the room or space will create undue hazard to occupants seeking egress in an emergency, in—\na Class 4 part of a building — to sanitary compartments, bathrooms, shower rooms, airlocks and laundries; and\na Class 2 building — to sanitary compartments, bathrooms, shower rooms, airlocks, laundries, common stairways and other spaces used in common by the occupants of the building; and\nClass 3, 5, 6, 7, 8 and 9 buildings — to all rooms that are frequently occupied, all spaces required to be accessible, all corridors, lobbies, internal stairways, other circulation spaces and paths of egress.\n(2) The artificial lighting system must comply with AS/NZS 1680.0.\n(3) The system may provide a lesser level of illumination to the following spaces during times when the level of lighting would be inappropriate for the use:\nA theatre, cinema or the like, when performances are in progress, with the exception of aisle lighting required by Part I1.\nA museum, gallery or the like, where sensitive displays require low lighting levels.\nA discotheque, nightclub or the like, where to create an ambience and character for the space, low lighting levels are used.","g":"/ncc/f6d5","a19":["F4.4"]},{"c":"F6D6","t":"Ventilation","p":"Part F6 Light and ventilation","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f6-light-and-ventilation#F6D6","x":"A habitable room, office, shop, factory, workroom, sanitary compartment, bathroom, shower room, laundry and any other room or space occupied by a person for any purpose must have—\nnatural ventilation complying with—\nF6D7; or\nAS 1668.4; or\na mechanical ventilation or air-conditioning system complying with AS 1668.2 and AS/NZS 3666.1.","g":"/ncc/f6d6","a19":["NSW F4.5(b)","SA F4.5(b) and (c)","F4.5"]},{"c":"F6D7","t":"Natural ventilation","p":"Part F6 Light and ventilation","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f6-light-and-ventilation#F6D7","x":"(1) Natural ventilation provided in accordance with F6D6(a) must consist of openings, windows, doors or other devices which can be opened—\nwith a ventilating area not less than 5% of the floor area of the room required to be ventilated; and\nopen to—\na suitably sized court, or space open to the sky; or\nan open verandah, carport, or the like; or\nan adjoining room in accordance with F6D8.\n(2) The requirements of (1)(a) do not apply to a Class 8 electricity network substation.","g":"/ncc/f6d7","a19":["F4.6"]},{"c":"F6D8","t":"Ventilation borrowed from adjoining room","p":"Part F6 Light and ventilation","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f6-light-and-ventilation#F6D8","x":"Natural ventilation to a room may come through a window, opening, door or other device from an adjoining room (including an enclosed verandah) if both rooms are within the same sole-occupancy unit or the enclosed verandah is common property, and—\nin a Class 2 building, a sole-occupancy unit of a Class 3 building or Class 4 part of a building—\nthe room to be ventilated is not a sanitary compartment; and\nthe window, opening, door or other device has a ventilating area of not less than 5% of the floor area of the room to be ventilated; and\nthe adjoining room has a window, opening, door or other device with a ventilating area of not less than 5% of the combined floor areas of both rooms; and\nin a Class 5, 6, 7, 8 (except a Class 8 electricity network substation) or 9 building—\nthe window, opening, door or other device has a ventilating area of not less than 10% of the floor area of the room to be ventilated, measured not more than 3.6 m above the floor; and\nthe adjoining room has a window, opening, door or other device with a ventilating area of not less than 10% of the combined floor areas of both rooms; and\nthe ventilating areas specified in (a) and (b) may be reduced as appropriate if direct natural ventilation is provided from another source.","g":"/ncc/f6d8","a19":["F4.7"]},{"c":"F6D9","t":"Restriction on location of sanitary compartments","p":"Part F6 Light and ventilation","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f6-light-and-ventilation#F6D9","x":"A sanitary compartment must not open directly into—\na kitchen or pantry; or\na public dining room or restaurant; or\na dormitory in a Class 3 building; or\na room used for public assembly (which is not an early childhood centre, primary school or open spectator stand); or\na workplace normally occupied by more than one person.","g":"/ncc/f6d9","a19":["F4.8"]},{"c":"F6D10","t":"Airlocks","p":"Part F6 Light and ventilation","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f6-light-and-ventilation#F6D10","x":"If a sanitary compartment is prohibited under F6D9 from opening directly to another room—\nin a sole-occupancy unit in a Class 2 or 3 building or Class 4 part of a building—\naccess must be by an airlock, hallway or other room; or\nthe sanitary compartment must be provided with mechanical exhaust ventilation; and\nin a Class 5, 6, 7, 8 or 9 building (which is not an early childhood centre, primary school or open spectator stand)—\naccess must be by an airlock, hallway or other room with a floor area of not less than 1.1 m2 and fitted with self-closing doors at all access doorways; or\nthe sanitary compartment must be provided with mechanical exhaust ventilation and the doorway to the room adequately screened from view.","g":"/ncc/f6d10","a19":["F4.9"]},{"c":"F6D11","t":"Carparks","p":"Part F6 Light and ventilation","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f6-light-and-ventilation#F6D11","x":"Every storey of a carpark, except an open-deck carpark, must have—\na system of mechanical ventilation complying with AS 1668.2; or\na system of natural ventilation complying with Section 4 of AS 1668.4.","g":"/ncc/f6d11","a19":["F4.11"]},{"c":"F6D12","t":"Kitchen local exhaust ventilation","p":"Part F6 Light and ventilation","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f6-light-and-ventilation#F6D12","x":"A kitchen must be provided with a kitchen exhaust hood system complying with AS 1668.1 and AS 1668.2 where—\nany cooking apparatus has—\na total maximum electrical power input exceeding 8 kW; or\na total gas power input exceeding 29 MJ/hour; or\nthe total maximum power input to more than one apparatus exceeds, per m2 of floor area of the room or enclosure—\n0.5 kW electrical power; or\n1.8 MJ/hour gas.","g":"/ncc/f6d12","a19":["F4.12"]},{"c":"F7O1","t":"Objective","p":"Part F7 Sound transmission and insulation","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f7-sound-transmission-and-insulation#F7O1","x":"The Objective of this Part is to safeguard occupants from illness or loss of amenity as a result of undue sound being transmitted—\nbetween adjoining sole-occupancy units; and\nfrom common spaces to sole-occupancy units; and\nfrom parts of different classifications to sole-occupancy units.\nApplications\nF7O1 only applies to a Class 2 or 3 building or a Class 9c building.","g":"/ncc/f7o1"},{"c":"F7F1","t":"Sound transmission and insulation","p":"Part F7 Sound transmission and insulation","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f7-sound-transmission-and-insulation#F7F1","x":"A part of a building that separates—\nsole-occupancy units; or\na sole-occupancy unit from a part of another classification in the building; or\na sole-occupancy unit from a common space,\nis to be constructed to prevent undue sound transmission.\nApplications\nF7F1 only applies to a Class 2 or 3 building or a Class 9c building.","g":"/ncc/f7f1","a19":["FF5.1"]},{"c":"F7P1","t":"Sound transmission through floors","p":"Part F7 Sound transmission and insulation","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f7-sound-transmission-and-insulation#F7P1","x":"A floor separating sole-occupancy units or a sole-occupancy unit from a plant room, lift shaft, stairway, public corridor, public lobby, or the like, or parts of a different classification, must minimise the transmission of airborne and impact generated sound such that the separating floor, including the effect of services and their penetrations, has—\na weighted standardised level difference with spectrum adaptation term (DnT,w + Ctr) not less than 45 for airborne sound; and\na weighted standardised impact sound pressure level (LnT,w) not more than 62 for impact generated sound.\nApplications\nF7P1 only applies to a Class 2 or 3 building.","g":"/ncc/f7p1","a19":["NT FP5.1","FP5.1"]},{"c":"F7P2","t":"Sound transmission through walls","p":"Part F7 Sound transmission and insulation","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f7-sound-transmission-and-insulation#F7P2","x":"A wall, including services and their penetrations, must minimise the transmission of sound such that—\nfor airborne sound—\na wall separating sole-occupancy units has a weighted standardised level difference with spectrum adaptation term (DnT,w + Ctr) not less than 45; and\na wall separating a sole-occupancy unit from a plant room, lift shaft, stairway, public corridor, public lobby, or the like, or parts of a different classification, has a weighted standardised level difference (DnT,w) not less than 45; and\nany door assembly located in a wall that separates a sole-occupancy unit from a stairway, public corridor, public lobby, or the like, has a weighted standardised level difference (DnT,w) not less than 25; and\nfor impact generated sound, a wall must have sufficient sound insulation to prevent illness or loss of amenity to the occupants if the wall separates—\na bathroom, sanitary compartment, laundry or kitchen in one sole-occupancy unit from a habitable room (other than a kitchen) in an adjoining sole-occupancy unit; or\na sole-occupancy unit from a plant room or lift shaft.\nApplications\nF7P2 only applies to a Class 2 or 3 building.","g":"/ncc/f7p2","a19":["NT FP5.2","FP5.2"]},{"c":"F7P3","t":"Sound transmission through floors in a residential care building","p":"Part F7 Sound transmission and insulation","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f7-sound-transmission-and-insulation#F7P3","x":"A floor separating sole-occupancy units must minimise the transmission of airborne and impact generated sound such that the separating floor, including the effect of services and their penetrations, has—\na weighted standardised level difference (DnT,w) not less than 40 for airborne sound; and\na weighted standardised impact sound pressure level (LnT,w) not more than 62 for impact generated sound.\nApplications\nF7P3 only applies to a Class 9c building.","g":"/ncc/f7p3","a19":["NT FP5.3","FP5.4"]},{"c":"F7P4","t":"Sound transmission through walls in a residential care building","p":"Part F7 Sound transmission and insulation","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f7-sound-transmission-and-insulation#F7P4","x":"(1) A wall separating sole-occupancy units, or a sole-occupancy unit from a kitchen, bathroom, sanitary compartment (not being an associated ensuite), laundry, plant room or utilities room, including the effect of services and their penetrations, must minimise the transmission of—\nairborne sound such that the wall has a weighted standardised level difference (DnT,w) not less than 40; and\nimpact generated sound, if the wall separates a sole-occupancy unit from a kitchen or laundry.\n(2) Sound insulation required by (1) must be sufficient to prevent illness or loss of amenity to the occupants.\nApplications\nF7P4 only applies to a Class 9c building.","g":"/ncc/f7p4","a19":["NT FP5.4","FP5.5"]},{"c":"F7V1","t":"Sound transmission through floors [F7P1]","p":"Part F7 Sound transmission and insulation","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f7-sound-transmission-and-insulation#F7V1","x":"Compliance with F7P1 to avoid the transmission of airborne and impact generated sound through floors is verified when it is measured in-situ that the separating floor has—\nairborne: a weighted standardised level difference with spectrum adaptation term (DnT,w + Ctr) not less than 45 when determined under AS ISO 717.1; and\nimpact: a weighted standardised impact sound pressure level (LnT,w) not more than 62 when determined under AS ISO 717.2.","g":"/ncc/f7v1","a19":["FV5.1"]},{"c":"F7V2","t":"Sound transmission through walls [F7P2(a)]","p":"Part F7 Sound transmission and insulation","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f7-sound-transmission-and-insulation#F7V2","x":"Compliance with F7P2(a) to avoid the transmission of airborne sound through walls is verified when it is measured in-situ that—\na wall separating sole-occupancy units has a weighted standardised level difference with spectrum adaptation term (DnT,w + Ctr) not less than 45 when determined under AS ISO 717.1; or\na wall separating a sole-occupancy unit from a plant room, lift shaft, stairway, public corridor, public lobby, or the like, or parts of a different classification, has a weighted standardised level difference (DnT,w) not less than 45 when determined under AS ISO 717.1; or\nany door assembly located in a wall that separates a sole-occupancy unit from a stairway, public corridor, public lobby, or the like, has a weighted standardised level difference (DnT,w) not less than 25 when determined under AS ISO 717.1.","g":"/ncc/f7v2","a19":["FV5.2"]},{"c":"F7V3","t":"Sound transmission through floors [F7P3]","p":"Part F7 Sound transmission and insulation","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f7-sound-transmission-and-insulation#F7V3","x":"Compliance with F7P3 to avoid the transmission of airborne and impact generated sound through floors is verified when it is measured in-situ that the separating floor has—\nairborne: a weighted standardised level difference (DnT,w) not less than 40 when determined under AS ISO 717.1; and\nimpact: a weighted standardised impact sound pressure level (LnT,w) not more than 62 when determined under AS ISO 717.2.","g":"/ncc/f7v3","a19":["FV5.3"]},{"c":"F7V4","t":"Sound transmission through walls [F7P4(1)(a) and (2)]","p":"Part F7 Sound transmission and insulation","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f7-sound-transmission-and-insulation#F7V4","x":"Compliance with F7P4(1)(a) and (2) to avoid the transmission of airborne sound through walls is verified when it is measured in-situ that—\na wall separating sole-occupancy units has a weighted standardised level difference (DnT,w) not less than 40 when determined under AS ISO 717.1; or\na wall separating a sole-occupancy unit from a kitchen, bathroom, sanitary compartment (not being an associated ensuite), laundry, plant room or utilities room has a weighted standardised level difference (DnT,w) not less than 40 when determined under AS ISO 717.1.","g":"/ncc/f7v4","a19":["FV5.4"]},{"c":"F7D1","t":"Deemed-to-Satisfy Provisions","p":"Part F7 Sound transmission and insulation","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f7-sound-transmission-and-insulation#F7D1","x":"(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements F7P1 to F7P4 are satisfied by complying with F7D2 to F7D8.\n(2) Where a Performance Solution is proposed, the relevant Performance Requirements must be determined in accordance with A2G2(3) and A2G4(3) as applicable.","g":"/ncc/f7d1","a19":["NT F5.0","F5.0"]},{"c":"F7D2","t":"Application of Part","p":"Part F7 Sound transmission and insulation","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f7-sound-transmission-and-insulation#F7D2","x":"The Deemed-to-Satisfy Provisions of this Part apply to Class 2 and 3 buildings and Class 9c buildings.","g":"/ncc/f7d2","a19":["NT F5.1","F5.1"]},{"c":"F7D3","t":"Determination of airborne sound insulation ratings","p":"Part F7 Sound transmission and insulation","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f7-sound-transmission-and-insulation#F7D3","x":"A form of construction required to have an airborne sound insulation rating must—\nhave the required value for weighted sound reduction index (Rw) or weighted sound reduction index with spectrum adaptation term (Rw + Ctr) determined in accordance with AS ISO 717.1 using results from laboratory measurements; or\ncomply with Specification 28.","g":"/ncc/f7d3","a19":["NT F5.2","F5.2"]},{"c":"F7D4","t":"Determination of impact sound insulation ratings","p":"Part F7 Sound transmission and insulation","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f7-sound-transmission-and-insulation#F7D4","x":"(1) A floor in a building required to have an impact sound insulation rating must—\nhave the required value for weighted normalised impact sound pressure level (Ln,w) determined in accordance with AS ISO 717.2 using results from laboratory measurements; or\ncomply with Specification 28.\n(2) A wall in a building required to have an impact sound insulation rating must—\nfor a Class 2 or 3 building be of discontinuous construction and\nfor a Class 9c building, must—\nfor other than masonry, be two or more separate leaves without rigid mechanical connection except at the periphery; or\nbe identical with a prototype that is no less resistant to the transmission of impact sound when tested in accordance with Specification 29 than a wall listed in S28C4 to S28C7.\n(3) For the purposes of this Part, discontinuous construction means a wall having a minimum 20 mm cavity between 2 separate leaves, and—\nfor masonry, where wall ties are required to connect leaves, the ties are of the resilient type; and\nfor other than masonry, there is no mechanical linkage between leaves except at the periphery.","g":"/ncc/f7d4","a19":["NT F5.3","F5.3"]},{"c":"F7D5","t":"Sound insulation rating of floors","p":"Part F7 Sound transmission and insulation","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f7-sound-transmission-and-insulation#F7D5","x":"(1) A floor in a Class 2 or 3 building must have an Rw + Ctr (airborne) not less than 50 and an Ln,w (impact) not more than 62 if it separates—\nsole-occupancy units; or\na sole-occupancy unit from a plant room, lift shaft, stairway, public corridor, public lobby or the like, or parts of a different classification.\n(2) A floor in a Class 9c building separating sole-occupancy units must have an Rw not less than 45.","g":"/ncc/f7d5","a19":["NT F5.4","F5.4"]},{"c":"F7D6","t":"Sound insulation rating of walls","p":"Part F7 Sound transmission and insulation","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f7-sound-transmission-and-insulation#F7D6","x":"(1) A wall in a Class 2 or 3 building must—\nhave an Rw + Ctr (airborne) not less than 50, if it separates sole-occupancy units; and\nhave an Rw (airborne) not less than 50, if it separates a sole-occupancy unit from a plant room, lift shaft, stairway, public corridor, public lobby or the like, or parts of a different classification; and\ncomply with F7D4(2) if it separates—\na bathroom, sanitary compartment, laundry or kitchen in one sole-occupancy unit from a habitable room (other than a kitchen) in an adjoining unit; or\na sole-occupancy unit from a plant room or lift shaft.\n(2) A door may be incorporated in a wall in a Class 2 or 3 building that separates a sole-occupancy unit from a stairway, public corridor, public lobby or the like, provided the door assembly has an Rw not less than 30.\n(3) A wall in a Class 9c building must have an Rw not less than 45 if it separates—\nsole-occupancy units; or\na sole-occupancy unit from a kitchen, bathroom, sanitary compartment (not being an associated ensuite), laundry, plant room or utilities room.\n(4) In addition to (3), a wall separating a sole-occupancy unit in a Class 9c building from a kitchen or laundry must comply with F7D4(2).\n(5) Where a wall required to have sound insulation has a floor above, the wall must continue to—\nthe underside of the floor above; or\na ceiling that provides the sound insulation required for the wall.\n(6) Where a wall required to have sound insulation has a roof above, the wall must continue to—\nthe underside of the roof above; or\na ceiling that provides the sound insulation required for the wall.","g":"/ncc/f7d6","a19":["NT F5.5 and NT Table F5.5","F5.5"]},{"c":"F7D7","t":"Sound insulation rating of internal services","p":"Part F7 Sound transmission and insulation","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f7-sound-transmission-and-insulation#F7D7","x":"(1) If a duct or soil, waste or water supply pipe, including a duct or pipe that is located in a wall or floor cavity, serves or passes through more than one sole-occupancy unit, the duct or pipe must be separated from the rooms of any sole-occupancy unit by construction with an Rw + Ctr (airborne) not less than—\n40 if the adjacent room is a habitable room (other than a kitchen); or\n25 if the adjacent room is a kitchen or non-habitable room.\n(2) If a stormwater pipe passes through a sole-occupancy unit, it must be separated in accordance with (1)(a) and (b).","g":"/ncc/f7d7","a19":["NT F5.6","F5.6"]},{"c":"F7D8","t":"Sound isolation of pumps","p":"Part F7 Sound transmission and insulation","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f7-sound-transmission-and-insulation#F7D8","x":"A flexible coupling must be used at the point of connection between the service pipes in a building and any circulating or other pump.","g":"/ncc/f7d8","a19":["NT F5.7","F5.7"]},{"c":"F8O1","t":"Objective","p":"Part F8 Condensation management","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f8-condensation-management#F8O1","x":"The Objective of this Part is to safeguard occupants from illness or loss of amenity as a result of excessive internal moisture.\nApplications\nF8O1 only applies to a sole-occupancy unit of a Class 2 building or Class 4 part of a building.","g":"/ncc/f8o1","a19":["FO6"]},{"c":"F8F1","t":"Condensation","p":"Part F8 Condensation management","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f8-condensation-management#F8F1","x":"A building is to be constructed to avoid the likelihood of excessive internal moisture accumulating within the building structure.\nApplications\nF8F1 only applies to a sole-occupancy unit of a Class 2 building or Class 4 part of a building.","g":"/ncc/f8f1","a19":["FF6.1"]},{"c":"F8P1","t":"Condensation and water vapour management","p":"Part F8 Condensation management","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f8-condensation-management#F8P1","x":"Risks associated with water vapour and condensation must be managed to minimise their impact on the health of occupants.\nApplications\nF8P1 only applies to a sole-occupancy unit of a Class 2 building or Class 4 part of a building.","g":"/ncc/f8p1","a19":["TAS FP6.1","FP6.1"]},{"c":"F8V1","t":"Condensation management","p":"Part F8 Condensation management","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f8-condensation-management#F8V1","x":"(1) Compliance with Performance Requirement F8P1 is verified for a roof or external wall assembly when it is determined that a mould index of greater than 3, as defined by Section 6 of AIRAH DA07, does not occur on—\nthe interior surface of the water control layer; or\nthe surfaces of building fabric components interior to the water control layer.\n(2) The calculation method for (1) must use—\ninput assumptions in accordance with AIRAH DA07; and\nthe intermediate method for calculating indoor design humidity in Section 4.3.2 of AIRAH DA07.","g":"/ncc/f8v1","a19":["FV6"]},{"c":"F8D1","t":"Deemed-to-Satisfy Provisions","p":"Part F8 Condensation management","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f8-condensation-management#F8D1","x":"(1) Compliance with Performance Requirement F8P1 is satisfied by complying with Deemed-to-Satisfy Provisions F8D2 to F8D6.\n(2) Where a Performance Solution is proposed, the relevant Performance Requirements must be determined in accordance with A2G2(3) and A2G4(3) as applicable.","g":"/ncc/f8d1","a19":["F6.0"]},{"c":"F8D2","t":"Application of Part","p":"Part F8 Condensation management","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f8-condensation-management#F8D2","x":"The Deemed-to-Satisfy Provisions of this Part only apply to a sole-occupancy unit of a Class 2 building and a Class 4 part of a building.","g":"/ncc/f8d2","a19":["F6.1"]},{"c":"Table F8D3","t":"Vapour permeance requirements","p":"Part F8 Condensation management","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f8-condensation-management#_de792b6c-f6bc-4559-9dd5-c9047e655ce6","x":"Climate zone | Wall construction | Vapour permeance (µg/N.s)\n1 | No cavity | ≥ 0.0022 to < 1.1403\nDrained and ventilated cavity | ≥ 0 to < 1.1403\n3 | No cavity | ≥ 0.1429\nDrained and ventilated cavity | ≥ 0.0022\n4, 5 | No cavity | ≥ 1.1403\nDrained and ventilated cavity | ≥ 0.1429\n6, 7, 8 | No cavity | X\nDrained and ventilated cavity | ≥ 1.1403\nTable Notes\nX = A cavity must be provided in climate zones 6, 7 and 8.","tb":"F8D3","g":"/ncc/table-f8d3"},{"c":"F8D3","t":"External wall construction","p":"Part F8 Condensation management","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f8-condensation-management#F8D3","x":"(1) Where a pliable building membrane or a sarking-type material is installed as a control layer in an external wall, it must—\ncomply with AS 4200.1; and\nbe installed in accordance with AS 4200.2.\n(2) Subject to (5), any control layer incorporated between the cladding and the exterior side of the primary insulation layer in an external wall must achieve the vapour permeance specified in Table F8D3.\n(3) Subject to (4) and (5), an external wall without a pliable building membrane or a water barrier between the cladding and the exterior side of the primary insulation layer, must incorporate a drained and ventilated cavity.\n(4) Subject to (5), for the purposes of (2) and (3), a drained and ventilated cavity must—\nbe located between the cladding and the external side of the primary insulation layer, or the outermost control layer; and\nconstructed from cavity battens, spacers or the like where applicable with a depth of at least 12 mm; and\nbe unobstructed by any control layer; and\nbe drained to the exterior, including where cavities are vertically compartmentalised in a multi-storey building; and\nhave openings with a free area of not less than 1,000 mm2/m of wall provided at—\nthe base and top of the cavity; or\neach storey or level to where the cavity is closed.\n(5) The requirements of (2), (3) and (4) do not apply to a—\nsingle skin masonry wall; or\nsingle skin concrete wall; or\nwall constructed from insulated sandwich panels for the full extent of the external wall; or\nwall that does not form part of the building envelope; or\nportion of the external wall below natural ground level.\nTable F8D3 Vapour permeance requirements\nClimate zone\nWall construction\nVapour permeance (µg/N.s)\n1\nNo cavity\n≥ 0.0022 to < 1.1403\nDrained and ventilated cavity\n≥ 0 to < 1.1403\n3\nNo cavity\n≥ 0.1429\nDrained and ventilated cavity\n≥ 0.0022\n4, 5\nNo cavity\n≥ 1.1403\nDrained and ventilated cavity\n≥ 0.1429\n6, 7, 8\nNo cavity\nX\nDrained and ventilated cavity\n≥ 1.1403\nTable Notes\nX = A cavity must be provided in climate zones 6, 7 and 8.","g":"/ncc/f8d3","a19":["F6.2"]},{"c":"F8D4","t":"Exhaust systems","p":"Part F8 Condensation management","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f8-condensation-management#F8D4","x":"(1) An exhaust system installed in a kitchen, bathroom, sanitary compartment or laundry must have a minimum flow rate of—\n25 L/s for a bathroom or sanitary compartment; and\n40 L/s for a kitchen or laundry.\n(2) Exhaust from a kitchen, kitchen range hood, bathroom, sanitary compartment or laundry must discharge directly or via a shaft or duct to outdoor air.\n(3) Where space for a clothes drying appliance is provided in accordance with F4D2(1)(b), space must also be provided for ducting from the clothes drying appliance to outdoor air.\n(4) (3) does not apply if a condensing-type clothes drying appliance is installed.\n(5) An exhaust system that is not run continuously and is serving a bathroom or sanitary compartment that is not ventilated in accordance with F6D7 must—\nbe interlocked with the room’s light switch; and\ninclude a run-on timer so that the exhaust system continues to operate for 10 minutes after the light switch is turned off.\n(6) Except for rooms that are ventilated in accordance with F6D7, a room with space for ducting a clothes drying appliance to outdoor air in accordance with (3) must be provided with make-up air in accordance with AS 1668.2.","g":"/ncc/f8d4","a19":["F6.3"]},{"c":"Table F8D5","t":"Roof space ventilation requirements","p":"Part F8 Condensation management","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f8-condensation-management#_2b38ca54-a45e-4311-b0f9-f1119cf060af","x":"Roof pitch | Ventilation openings\n<10° | 20,000 mm2/m provided at eaves or low level, or at each of two opposing ends for gable roofs\nFor roofs less than 10 m2, 7,000 mm2/m provided at eaves or low level roof perimeter and 5,000 mm2/m provided at ridge or high level for skillion roofs\n20,000 mm2/m provided at the eaves or low level and 5,000 mm2/m provided at ridge or high level for skillion roofs\n≥10° and <75° | 7,000 mm2/m provided at the eaves or low level and 5,000 mm2/m provided at high level or ridge\nTable Notes\nVentilation openings are specified as a minimum free open area per metre length. The longest total plan dimension is based on the roof length irrespective of the number of storeys beneath.\nTotal low level ventilation openings are calculated based on twice the longest total plan dimension of the roof, except for mono pitch or skillion roofs that are calculated based on the longest total plan dimension of the roof. Total high level ventilation is calculated based on the longest total plan dimension of the roof.\nHigh level openings are openings provided at the ridge or not more than 900 mm below the ridge or highest point of the roof space, measured vertically or 1/3 of the height of the roof below highest point of the roof, whichever is least.","tb":"F8D5","g":"/ncc/table-f8d5"},{"c":"F8D5","t":"Ventilation of a roof space with the primary insulation layer not parallel to the roof plane","p":"Part F8 Condensation management","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f8-condensation-management#F8D5","x":"(1) In climate zones 6, 7 and 8, a roof with the primary insulation layer not parallel to the roof plane must have a roof space that—\nhas a height not less than 18 mm at any point between the primary insulation layer and the underside of the roof or a control layer; and\nis located immediately above the primary insulation layer; and\nis ventilated to outdoor air, in accordance with Table F8D5.\n(2) The requirements of (1) do not apply to a—\nconcrete roof; or\nroof that is made of insulated sandwich panels; or\nroof that is subject to Bushfire Attack Level FZ requirements in accordance with AS 3959.\ntiled roof without a control layer.\nTable F8D5 Roof space ventilation requirements\nRoof pitch\nVentilation openings\n<10°\n20,000 mm2/m provided at eaves or low level, or at each of two opposing ends for gable roofs\nFor roofs less than 10 m2, 7,000 mm2/m provided at eaves or low level roof perimeter and 5,000 mm2/m provided at ridge or high level for skillion roofs\n20,000 mm2/m provided at the eaves or low level and 5,000 mm2/m provided at ridge or high level for skillion roofs\n≥10° and <75°\n7,000 mm2/m provided at the eaves or low level and 5,000 mm2/m provided at high level or ridge\nTable Notes\nVentilation openings are specified as a minimum free open area per metre length. The longest total plan dimension is based on the roof length irrespective of the number of storeys beneath.\nTotal low level ventilation openings are calculated based on twice the longest total plan dimension of the roof, except for mono pitch or skillion roofs that are calculated based on the longest total plan dimension of the roof. Total high level ventilation is calculated based on the longest total plan dimension of the roof.\nHigh level openings are openings provided at the ridge or not more than 900 mm below the ridge or highest point of the roof space, measured vertically or 1/3 of the height of the roof below highest point of the roof, whichever is least.","g":"/ncc/f8d5","a19":["F6.4"]},{"c":"F8D6","t":"Ventilation of a roof space with the primary insulation layer parallel to the roof plane","p":"Part F8 Condensation management","u":"/editions/ncc-2025/adopted/volume-one/f-health-and-amenity/part-f8-condensation-management#F8D6","x":"(1) In climate zones 6, 7 and 8, a roof system with the primary insulation layer installed parallel to the roof plane must have a roof space that—\nis located immediately above—\nthe primary insulation layer; or\nany control layer installed immediately above the primary insulation layer; and\nis not obstructed by insulation; and\nhas a height not less than 18 mm, as measured perpendicular to the plane of the roof; and\nfor roofs less than 10 m2, is ventilated to outdoor air through openings not less than—\n7,000 mm2/m provided at eaves or low level; and\n5,000 mm2/m at the high level or ridge; and\nfor all other roofs, is ventilated to outdoor air through openings not less than—\n20,000 mm2/m provided at the eaves or low level; and\n5,000 mm2/m provided at the high level or ridge.\n(2) Where a control layer is installed immediately above the primary insulation layer in climate zone s 6, 7 and 8, it must have a vapour permeance of not less than 1.14 μg/N.s.\n(3) The requirements of (1) do not apply to a—\nconcrete roof; or\nroof that is made of insulated sandwich panels with or without an additional ceiling linings; or\nroof that is subject to Bushfire Attack Level FZ requirement in accordance with AS 3959; or\ntiled roof without a control layer located above the primary insulation layer.\nFigure F8D6c (explanatory) Example of a roof space in accordance with F8D6(1)(a)(ii)\nFigure Notes\nRoof space above the control layer, water barrier or sheathing.\nControl layers immediately above primary insulation layer must have a vapour permeance of 1.14μg/N.s.","g":"/ncc/f8d6"},{"c":"S30C1","t":"Scope","p":"Specification 30 Installation of boilers and pressure vessels","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/30-installation-boilers-and-pressure-vessels#S30C1","x":"This Specification sets out the requirements for the installation of boilers and pressure vessels in buildings.","g":"/ncc/s30c1","a19":["Spec G2.2: 1"]},{"c":"Table S30C2","t":"Minimum clearances for explosion relief","p":"Specification 30 Installation of boilers and pressure vessels","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/30-installation-boilers-and-pressure-vessels#_2104148b-c242-43a3-b77c-8f13aefe1a96","x":"Clearance from | Minimum clearance (metres)\nAdjacent wall or ceiling/roof | or 0.4 m, whichever is the greater\nTwo walls at right angles; or one wall and a ceiling/roof | or 0.6 m, whichever is the greater\nTable Notes\nFor the purposes of this table, is the internal volume of the boiler or pressure vessel being vented up to the connection of the flue.","tb":"S30C2","g":"/ncc/table-s30c2"},{"c":"S30C2","t":"Explosion relief","p":"Specification 30 Installation of boilers and pressure vessels","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/30-installation-boilers-and-pressure-vessels#S30C2","x":"The distance between the vent of any explosion relief device for a boiler or pressure vessel and any adjacent wall, roof, ceiling or other solid construction shall be calculated in accordance with Table S30C2.\nTable S30C2 Minimum clearances for explosion relief\nClearance from\nMinimum clearance (metres)\nAdjacent wall or ceiling/roof\n[formula] or 0.4 m, whichever is the greater\nTwo walls at right angles; or one wall and a ceiling/roof\n[formula] or 0.6 m, whichever is the greater\nTable Notes\nFor the purposes of this table, [formula] is the internal volume of the boiler or pressure vessel being vented up to the connection of the flue.","g":"/ncc/s30c2","a19":["Spec G2.2: 2.1"]},{"c":"S30C3","t":"Floors and drainage","p":"Specification 30 Installation of boilers and pressure vessels","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/30-installation-boilers-and-pressure-vessels#S30C3","x":"(1) Floor surfaces beneath boilers and pressure vessels shall be water resistant and formed to drain away from supports and structural building elements.\n(2) Where a safe tray is provided to trap liquids, it must be manufactured from a material resistant to corrosion from the contents of the boiler or pressure vessel.","g":"/ncc/s30c3","a19":["Spec G2.2: 2.2"]},{"c":"S30C4","t":"Protection from heat","p":"Specification 30 Installation of boilers and pressure vessels","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/30-installation-boilers-and-pressure-vessels#S30C4","x":"Building elements surrounding a boiler must be protected from any surface heat by refractory material or effective air spaces so that—\nsteel elements do not exceed a temperature of more than 300°C; and\nconcrete elements do not exceed a temperature of more than 200°C; and\ntimber elements do not exceed a temperature of more than 150°C.","g":"/ncc/s30c4","a19":["Spec G2.2: 2.3"]},{"c":"S31C1","t":"Scope","p":"Specification 31 Fire and smoke control systems in buildings containing atriums","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/31-fire-and-smoke-control-systems-buildings-containing-atriums#S31C1","x":"This Specification sets out the requirements for the design and operation of systems of fire and smoke control in buildings containing an atrium.","g":"/ncc/s31c1","a19":["Spec G3.8: 1"]},{"c":"S31C2","t":"General requirement — automatic fire sprinkler system","p":"Specification 31 Fire and smoke control systems in buildings containing atriums","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/31-fire-and-smoke-control-systems-buildings-containing-atriums#S31C2","x":"A sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17 must be installed in every building containing an atrium, except where varied or superseded by this Specification.","g":"/ncc/s31c2","a19":["Spec G3.8: 2.1"]},{"c":"S31C3","t":"Roof protection","p":"Specification 31 Fire and smoke control systems in buildings containing atriums","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/31-fire-and-smoke-control-systems-buildings-containing-atriums#S31C3","x":"(1) A roof of an atrium which does not have the FRL prescribed in Specification 5 or the Deemed-to-Satisfy Provisions of Part C3 must be protected by automatic sprinklers arranged to wet both the covering membrane and supporting structure if the roof is—\nless than 12 m above the floor of the atrium or the floor of the highest storey where the bounding construction is set back more than 3.5 m from the atrium well if a Class 2, 3, 5 or 9 part of a building is open to the atrium; or\nless than 20 m above the floor of the atrium or the floor of the highest storey where the bounding construction is set back more than 3.5 m from the atrium well if a Class 6, 7 or 8 part of a building is open to the atrium.\n(2) The temperature rating of sprinkler heads required by (1) must be within the range 79°C – 100°C","g":"/ncc/s31c3","a19":["Spec G3.8: 2.2"]},{"c":"S31C4","t":"Atrium floor protection","p":"Specification 31 Fire and smoke control systems in buildings containing atriums","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/31-fire-and-smoke-control-systems-buildings-containing-atriums#S31C4","x":"The floor of the atrium must be protected by sprinklers with—\nthe use of sidewall pattern sprinkler heads together with overhead sprinklers where dictated by the dimensions of the atrium; and\nsprinkler heads of the quick response type.","g":"/ncc/s31c4","a19":["Spec G3.8: 2.3"]},{"c":"S31C5","t":"Sprinkler systems to glazed walls","p":"Specification 31 Fire and smoke control systems in buildings containing atriums","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/31-fire-and-smoke-control-systems-buildings-containing-atriums#S31C5","x":"(1) Where an atrium is separated from the remainder of the building by walls or doors incorporating glazing, a wall wetting system must be provided to protect the glazing as follows:\nOn the atrium side of the glazing — to all glazed walls which are set back more than 3.5 m from the atrium well.\nOn the atrium side of the glazing — to all glazed walls which are not set back, or are set back 3.5 m or less, from the atrium well, for all levels which are less than—\n12 m above the floor of an atrium or the floor of the highest storey where the bounding wall is set back more than 3.5 m from the atrium well if a Class 2, 3, 5 or 9 part of the building is open to the atrium; or\n20 m above the floor of an atrium or the floor of the highest storey where the bounding wall is set back more than 3.5 m from the atrium well if a Class 6, 7 or 8 part of the building is open to the atrium.\nOn the side of the glazing away from the atrium well — to all glazing forming part of the bounding wall at each storey.\n(2) Sprinklers must be located in positions allowing full wetting of the glazing surfaces without wetting adjacent sprinkler heads.\n(3) Sprinkler heads must be of the quick response type and have a maximum temperature rating of 74°C.\n(4) The rate of water discharge to protect glazing must be not less than—\non the atrium side of the glazing—\n0.25 L/s.m2 where glazing is not set back from the atrium well; or\n0.167 L/s.m2 where glazing is set back from the atrium well; and\non the side away from the atrium well — 0.167 L/s.m2.\n(5) In addition to that of the basic sprinkler protection for the building, the water supply to required wall wetting systems must be of adequate capacity to accommodate the following on the atrium side of the glazing:\nWhere the bounding walls are set back less than 3.5 m from the atrium well — wall wetting of a part not less than 6 m long for a height of not less than—\n12 m above the floor of an atrium or the floor of the highest storey where the bounding wall is set back more than 3.5 m from the atrium well if a Class 2, 3, 5 or 9 part of the building is open to the atrium; or\n20 m above the floor of an atrium or the floor of the highest storey where the bounding wall is set back more than 3.5 m from the atrium well if a Class 6, 7 or 8 part of the building is open to the atrium.\nWhere the walls are set back 3.5 m or more from the atrium well — wetting of a part not less than 12 m long on one storey.","g":"/ncc/s31c5","a19":["Spec G3.8: 2.4.1 – 2.4.5"]},{"c":"S31C6","t":"Stop valves","p":"Specification 31 Fire and smoke control systems in buildings containing atriums","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/31-fire-and-smoke-control-systems-buildings-containing-atriums#S31C6","x":"(1) Basic sprinkler and wall wetting systems protecting a building containing an atrium must be provided with easily accessible and identified stop valves.\n(2) Sprinkler and wall wetting systems must be provided with independent stop valves.\n(3) Sprinkler heads protecting the roof of the atrium must be provided with a stop valve.\n(4) Stop valves to wall wetting and roof sprinklers may be of the gate type.\n(5) All sprinkler and wall wetting stop valves must be monitored to detect unauthorised closure.","g":"/ncc/s31c6","a19":["Spec G3.8: 2.5"]},{"c":"S31C7","t":"General requirements — smoke control system","p":"Specification 31 Fire and smoke control systems in buildings containing atriums","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/31-fire-and-smoke-control-systems-buildings-containing-atriums#S31C7","x":"Except where varied or superseded by this Specification, mechanical air handling systems in a building containing an atrium must comply with AS 1668.1.","g":"/ncc/s31c7","a19":["Spec G3.8: 3.1"]},{"c":"S31C8","t":"Operation of atrium mechanical air-handling systems","p":"Specification 31 Fire and smoke control systems in buildings containing atriums","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/31-fire-and-smoke-control-systems-buildings-containing-atriums#S31C8","x":"Mechanical air-handling systems serving an atrium must be designed to operate so that during a fire—\na tenable atmosphere is maintained in all paths of travel along balconies to required exits during the period of evacuation; and\nsmoke exhaust fans serving the atrium are only activated when smoke enters the atrium; and\ncentral plant systems do not use the atrium as a return air path; and\ncentral plant systems which use return air paths remote from the atrium —\ncycle to the full outside air mode; and\nstop supply air to the fire affected storey or fire compartment; and\ncontinue to fully exhaust the fire affected storey or fire compartment and reduce the exhaust from other storeys or fire compartments by at least 75%; and\ncontinue to supply air to fire compartments or storeys other than the fire affected storey or fire compartment; and\nfans performing relief or exhaust duty from the atrium stop normal operation; and\nfloor by floor, or unitary, air-handling plant serving a single fire compartment or storey —\nceases normal operation in the fire affected storey or fire compartment; and\ncommences full relief or exhaust from that fire affected storey or fire compartment; and\ncontinue to supply air to fire compartments or storeys other than the fire affected storey or fire compartment.","g":"/ncc/s31c8","a19":["Spec G3.8: 3.2"]},{"c":"S31C9","t":"Activation of smoke control system","p":"Specification 31 Fire and smoke control systems in buildings containing atriums","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/31-fire-and-smoke-control-systems-buildings-containing-atriums#S31C9","x":"(1) The smoke control system must be activated by—\noperation of an automatic fire alarm; or\noperation of the sprinkler system; or\na manual start switch.\n(2) All controls for the smoke control system must be located—\nin the fire control room; or\nin the emergency control centre (if any); or\nadjacent to the sprinkler control valves; or\nincorporated in the Fire Indicator Panel.","g":"/ncc/s31c9","a19":["Spec G3.8: 3.3"]},{"c":"S31C10","t":"Smoke exhaust system","p":"Specification 31 Fire and smoke control systems in buildings containing atriums","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/31-fire-and-smoke-control-systems-buildings-containing-atriums#S31C10","x":"A smoke exhaust system serving an atrium must be designed on the basis of—\nthe sprinkler system limiting the size of a fire to—\na heat output of 1.5 MW and perimeter of 7.5 m if a Class 2, 3, 5 or 9 part of the building is open to the atrium; or\na heat output of 5 MW and perimeter of 12 m if a Class 6, 7 or 8 part of the building is open to the atrium; and\na smoke plume reaching a level 3 m above the highest storey having a path of travel to a required exit along a balcony bounding the atrium well, and not less than—\n12 m above the floor of an atrium or the floor of the highest storey where the bounding wall is set back more than 3.5 m from the atrium well if a Class 2, 3, 5 or 9 part of the building is open to the atrium; or\n20 m above the floor of an atrium or the floor of the highest storey where the bounding construction is set back more than 3.5 m from the atrium well if a Class 6, 7 or 8 part of the building is open to the atrium; and\nthe smoke exhaust system discharging smoke at a rate of not less than that shown in Figure S31C10 for the appropriate height of smoke plume and fire size—\nfrom the top of the atrium; or\nhorizontally, where calculations of wind velocity induced pressure profiles for the building verify that the exhaust system will operate effectively for all wind directions.\nFigure S31C10 Smoke exhaust rate","g":"/ncc/s31c10","a19":["Spec G3.8: 3.4"]},{"c":"S31C11","t":"Upward air velocity","p":"Specification 31 Fire and smoke control systems in buildings containing atriums","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/31-fire-and-smoke-control-systems-buildings-containing-atriums#S31C11","x":"Notwithstanding S31C10(c), the average upward air velocity in the atrium, due to the required smoke exhaust quantity must—\nbe not less than 0.2 m/s at any level over an 18 m height above the floor of the atrium; and\nnot exceed the following maximum velocities in atriums of constant cross sectional plan area:\nFor occupancy classification qualifying for 1.5 MW fire size — 3.5 m/s.\nFor occupancy classifications qualifying for 5 MW fire size — 5 m/s.","g":"/ncc/s31c11","a19":["Spec G3.8: 3.5"]},{"c":"S31C12","t":"Exhaust fans","p":"Specification 31 Fire and smoke control systems in buildings containing atriums","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/31-fire-and-smoke-control-systems-buildings-containing-atriums#S31C12","x":"(1) Smoke exhaust must be provided by fans capable of continuous and required operation for a period of not less than 1 hour when handling exhaust gases at 200°C.\n(2) Where a Class 2, 3 or 9 part of a building adjoins an atrium, the atrium must be provided with a minimum of 3 fans each capable of 50% of the total required smoke exhaust capacity.\n(3) Atriums other than those referred to in (2) must be provided with a minimum of 2 fans each capable of 50% of the total required smoke exhaust capacity.","g":"/ncc/s31c12","a19":["Spec G3.8: 3.6"]},{"c":"S31C13","t":"Smoke-and-heat vents","p":"Specification 31 Fire and smoke control systems in buildings containing atriums","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/31-fire-and-smoke-control-systems-buildings-containing-atriums#S31C13","x":"Notwithstanding S31C12, automatic vents complying with AS 2665 may be used, except where a Class 6 part of a building adjoins the atrium, in lieu of exhaust fans provided that—\nthe height from the atrium floor to the bottom of the highest vent is not more than 12 m; and\nthe vents are fitted with a remote manual operation switch located adjacent to the sprinkler control valves or incorporated in the Fire Indicator Panel.","g":"/ncc/s31c13","a19":["Spec G3.8: 3.7"]},{"c":"S31C14","t":"Make-up air supply","p":"Specification 31 Fire and smoke control systems in buildings containing atriums","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/31-fire-and-smoke-control-systems-buildings-containing-atriums#S31C14","x":"(1) Uniformly distributed make-up air must be provided to the atrium exhaust system from—\noutside the atrium at or near the lowest storey level; and\nrelief air from non-fire storeys.\n(2) A discharge volume sufficient to maintain a velocity of not less than 0.1 m/s towards the atrium well must be provided on all storeys where the bounding wall is set back from the atrium well.\n(3) The requirements of (1)(a) are satisfied if make-up air is provided to the atrium exhaust system in such a manner as to prevent, as far as possible, disturbance of the smoke layer due to turbulence created by the incoming air, through—\nopenings directly from the outside air to the atrium and located as close as practicable to the lowest level of the atrium; or\nducts from the outside air to the atrium which deliver air as close as practicable to the lowest level of the atrium and, where passing through any other fire compartment having an FRL of at least 60/60/60; or\na combination of (a) or (b).","g":"/ncc/s31c14","a19":["Spec G3.8: 3.8"]},{"c":"S31C15","t":"General requirements—fire detection and alarm system","p":"Specification 31 Fire and smoke control systems in buildings containing atriums","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/31-fire-and-smoke-control-systems-buildings-containing-atriums#S31C15","x":"Except where superseded by this Specification, automatic fire detection and alarm systems in a building containing an atrium must comply with AS 1670.1.","g":"/ncc/s31c15","a19":["Spec G3.8: 4.1"]},{"c":"S31C16","t":"Smoke detection system","p":"Specification 31 Fire and smoke control systems in buildings containing atriums","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/31-fire-and-smoke-control-systems-buildings-containing-atriums#S31C16","x":"Smoke detection within an atrium —\nmust be provided within all outside air intakes and at individual floor return air intakes of all air-handling systems to initiate automatic fire mode operation, and where applicable, comply with the restart facilities in AS 1668.1; and\nmust operate at an obscuration level not greater than 0.5% per metre with compensation for external airborne contamination as necessary; and\nmust sample air within the atrium and in storeys where the bounding wall is set back more than 3.5 m from the atrium well; and\nmust be calibrated to compensate for smoke dilution where sampling occurs within return air path common to more than one room; and\nmay incorporate beam type detectors to sense smoke in an atrium in a Class 5, 6, 7 or 8 building with an effective height of not more than 25 m if the beam detectors are—\nlocated at intervals of not more than 3 storeys; and\narranged to scan at 90 degrees orientation to adjacent beam units.","g":"/ncc/s31c16","a19":["Spec G3.8: 4.2"]},{"c":"S31C17","t":"Smoke detection in spaces separated from the atrium by bounding walls","p":"Specification 31 Fire and smoke control systems in buildings containing atriums","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/31-fire-and-smoke-control-systems-buildings-containing-atriums#S31C17","x":"Smoke detection systems must be located at all return and relief air openings associated with the building air-handling systems and be—\nof the sampling type system as required in S31C16; or\nof the point type photoelectric smoke detector.","g":"/ncc/s31c17","a19":["Spec G3.8: 4.3"]},{"c":"S31C18","t":"Alarm systems","p":"Specification 31 Fire and smoke control systems in buildings containing atriums","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/31-fire-and-smoke-control-systems-buildings-containing-atriums#S31C18","x":"(1) A break-glass fire alarm point must be provided at each door to a fire-isolated stairway, fire-isolated ramp or fire-isolated passageway.\n(2) A staged alarm must be provided where an air sampling type smoke detection system is provided for the atrium, and must operate as follows:\nAlert building management when abnormal smoke levels of 0.03% obscuration per metre are detected.\nInitiate a second alarm to management and start all smoke control systems including pressurisation of escape routes when smoke levels of 0.07% obscuration per metre are detected.\nAutomatically call the fire brigade, activate the emergency warning and intercom system, and de-activate all plant not necessary for fire safety within the building when smoke levels of 0.09% obscuration per metre are detected.\n(3) Beam and point type smoke detectors required must simultaneously operate all functions referred to above and activate at the level set out in AS 1670.1.","g":"/ncc/s31c18","a19":["Spec G3.8: 4.4"]},{"c":"S31C19","t":"Emergency warning and intercom systems","p":"Specification 31 Fire and smoke control systems in buildings containing atriums","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/31-fire-and-smoke-control-systems-buildings-containing-atriums#S31C19","x":"A building containing an atrium must be provided with an emergency warning and intercom system which—\ncomplies with AS 1670.4; and\nincorporates visual warning devices that—\noperate upon the evacuation signal; and\ndisplay the word “EVACUATE” in red with letters conforming with the requirements of the Deemed-to-Satisfy Provisions of Part E4 for exit signs.","g":"/ncc/s31c19","a19":["Spec G3.8: 5"]},{"c":"S31C20","t":"Standby power system","p":"Specification 31 Fire and smoke control systems in buildings containing atriums","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/31-fire-and-smoke-control-systems-buildings-containing-atriums#S31C20","x":"(1) If a required path of travel to an exit is within an atrium, a suitable alternative power supply must be provided to operate required safety systems, including sprinkler systems and fire hydrant pumps, air handling systems, alarms, warning and communication systems and emergency lighting circuits.\n(2) The alternative power supply must—\nbe connected automatically if the normal power supply fails; and\nif located within the building, be separated from the remainder of the building by an enclosure with an FRL of at least 120/120/120; and\nbe connected to the safety systems by means of cabling complying with C3D14(3).\n(3) The requirements of (1) are satisfied by—\na single medium voltage supply taken from an electricity substation situated within, or adjacent to, the building concerned where the power supply to the substation consists of two or more high voltage cables each taking electricity from separate transformers; or\ntwo or more medium voltage supplies each taking electricity from separate electricity substations situated—\noutside the building concerned; and\nat a suitable distance from each other; or\na single medium voltage supply taken from an electricity substation together with an electricity generating plant capable of—\ngenerating a medium voltage supply; and\nstarting and taking the required electrical load within a period of not more than 30 seconds from the time of normal supply failure.","g":"/ncc/s31c20","a19":["Spec G3.8: 6"]},{"c":"S31C21","t":"System for excluding smoke from fire-isolated exits","p":"Specification 31 Fire and smoke control systems in buildings containing atriums","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/31-fire-and-smoke-control-systems-buildings-containing-atriums#S31C21","x":"Required fire-isolated exits in a building containing an atrium must be protected from the entry of smoke in accordance with E2D3.","g":"/ncc/s31c21","a19":["Spec G3.8: 7"]},{"c":"S43C1","t":"Scope","p":"Specification 43 Bushfire protection for certain Class 9 buildings","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/43-bushfire-protection-certain-class-9-buildings#S43C1","x":"(1) This Specification sets out bushfire protection measures for buildings described in G5D4.\n(2) Compliance with this Specification does not guarantee the safety of building occupants or the maintenance of tenable conditions within a building during a bushfire event.","g":"/ncc/s43c1"},{"c":"Table S43C2","t":"Minimum distance of building to classified vegetation","p":"Specification 43 Bushfire protection for certain Class 9 buildings","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/43-bushfire-protection-certain-class-9-buildings#_b50ca146-dff8-4e48-96a1-73265bf618f1","x":"Vegetation classification | Slope | Minimum distance (m) of the building to classified vegetation\nHigh risk | Upslope and flat land | 60\nHigh risk | Downslope max 20 degrees | 110\nMedium risk | Upslope and flat land | 40\nMedium risk | Downslope max 20 degrees | 80\nLow risk | Upslope and flat land | 30\nLow risk | Downslope max 20 degrees | 50\nTable Notes\nTable values are based on a Fire Danger Index of 100 in accordance with AS 3959.\nHigh risk equates to vegetation classification of forest and woodland in accordance with AS 3959.\nMedium risk equates to vegetation classification of scrub and rainforest in accordance with AS 3959.\nLow risk equates to vegetation classification of shrubland, mallee/mulga and grassland in accordance with AS 3959.","tb":"S43C2","g":"/ncc/table-s43c2"},{"c":"S43C2","t":"Separation from classified vegetation","p":"Specification 43 Bushfire protection for certain Class 9 buildings","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/43-bushfire-protection-certain-class-9-buildings#S43C2","x":"(1) The building must be separated from classified vegetation—\nby not less than the minimum distances specified in Table S43C2; or\nsuch that radiant heat flux on exposed building elements will not exceed 10kW/m².\n(2) For the purposes of (1), the term ‘classified vegetation’ has the meaning that it has in AS 3959.\nTable S43C2 Minimum distance of building to classified vegetation\nVegetation classification\nSlope\nMinimum distance (m) of the building to classified vegetation\nHigh risk\nUpslope and flat land\n60\nHigh risk\nDownslope max 20 degrees\n110\nMedium risk\nUpslope and flat land\n40\nMedium risk\nDownslope max 20 degrees\n80\nLow risk\nUpslope and flat land\n30\nLow risk\nDownslope max 20 degrees\n50\nTable Notes\nTable values are based on a Fire Danger Index of 100 in accordance with AS 3959.\nHigh risk equates to vegetation classification of forest and woodland in accordance with AS 3959.\nMedium risk equates to vegetation classification of scrub and rainforest in accordance with AS 3959.\nLow risk equates to vegetation classification of shrubland, mallee/mulga and grassland in accordance with AS 3959.","g":"/ncc/s43c2"},{"c":"S43C3","t":"Separation between buildings","p":"Specification 43 Bushfire protection for certain Class 9 buildings","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/43-bushfire-protection-certain-class-9-buildings#S43C3","x":"(1) The building must be located not less than 12 m from any other building.\n(2) The separation distance required by (1) need not be complied with if the building is constructed—\nwith external walls that have an FRL of not less than 60/60/60 when tested from the outside, including any openings protected in accordance with AS 3959 for BAL—19 or greater; or\nfor external walls and roof, using a material or system that satisfies the test criteria of AS 1530.8.1 for a radiant heat flux of 10 kW/m² or greater.","g":"/ncc/s43c3"},{"c":"S43C4","t":"Separation from allotment boundaries and carparking areas","p":"Specification 43 Bushfire protection for certain Class 9 buildings","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/43-bushfire-protection-certain-class-9-buildings#S43C4","x":"(1) The building must be located not less than 10 m from any allotment boundary or open carparking area/spots.\n(2) The separation distance required by (1) need not be complied with if the building is constructed—\nwith external walls that have an FRL of not less than 60/60/60 when tested from the outside, including any openings protected in accordance with AS 3959 for BAL—19 or greater; or\nfor external walls and roof, using a material or system that satisfies the test criteria of AS 1530.8.1 for a radiant heat flux of 10 kW/m² or greater.","g":"/ncc/s43c4"},{"c":"S43C5","t":"Separation from hazards","p":"Specification 43 Bushfire protection for certain Class 9 buildings","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/43-bushfire-protection-certain-class-9-buildings#S43C5","x":"The external walls and roof of the building must be protected from potential hazards on the site such as liquefied petroleum gas bottles, fuel storage, storage of combustible materials, waste bins, vehicles, machinery, and the like, by—\na separation distance of not less than 10 m; or\nwhere within the 10 m separation distance described in (a), constructed with external walls that have an FRL of not less than 60/60/60 when tested from the outside, including any openings protected in accordance with AS 3959 for BAL—19 or greater; or\nfor external walls and roof, using a material or system that satisfies the test criteria of AS 1530.8.1 for a radiant heat flux of 10 kW/m² or greater.","g":"/ncc/s43c5"},{"c":"S43C6","t":"Non-combustible path around building","p":"Specification 43 Bushfire protection for certain Class 9 buildings","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/43-bushfire-protection-certain-class-9-buildings#S43C6","x":"A non-combustible pathway directly adjacent to the building and not less than 1.5 m wide must be provided around the perimeter of the building.","g":"/ncc/s43c6"},{"c":"S43C7","t":"Access pathways","p":"Specification 43 Bushfire protection for certain Class 9 buildings","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/43-bushfire-protection-certain-class-9-buildings#S43C7","x":"(1) Access pathways that lead to a road or open space must—\nbe readily identifiable; and\nhave an even surface; and\nhave a minimum clear width of not less than 1 m.\n(2) If the access pathway is an accessway that is required to comply with Part D4, the requirements of Part D4 override (1) to the extent of any inconsistency.","g":"/ncc/s43c7"},{"c":"S43C8","t":"Exposed external areas","p":"Specification 43 Bushfire protection for certain Class 9 buildings","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/43-bushfire-protection-certain-class-9-buildings#S43C8","x":"An external area designed to hold people unable to be safely accommodated within the building, that may be exposed to radiant heat flux from a fire front during a bushfire event, must not be exposed to an incident radiant heat flux from the fire front exceeding 1 kW/m2 above background solar radiant heat flux.","g":"/ncc/s43c8"},{"c":"S43C9","t":"Internal tenability","p":"Specification 43 Bushfire protection for certain Class 9 buildings","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/43-bushfire-protection-certain-class-9-buildings#S43C9","x":"To maintain internal tenability throughout the duration of occupancy during a bushfire event, the building must comply with the following:\nAn air handling system must be provided that is capable of—\nbeing adjusted for full recycling of internal air for a period of not less than 4 hours to avoid the introduction of smoke into the building; and\nmaintaining an internal air temperature of not more than 25°C.\nThe building envelope must be designed such that if an air handling system required by (a) fails, then—\ninternal air temperatures can be maintained below 39°C; and\ninternal surface temperatures can be maintained below 60°C.\nIf the building is divided into separate compartments then, for the purposes of (a), each compartment must have a separate air handling system.\nEach air handling system required by (a) must be designed to account for the activation of smoke detectors from low concentrations of smoke from external sources, so as to ensure that air-conditioning and other essential systems remain operational.","g":"/ncc/s43c9"},{"c":"S43C10","t":"Building envelope","p":"Specification 43 Bushfire protection for certain Class 9 buildings","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/43-bushfire-protection-certain-class-9-buildings#S43C10","x":"The building envelope must be constructed in accordance with AS 3959 – BAL 19 or greater, except that where the use of combustible materials is permitted by AS 3959, they are not to be used unless permitted by C2D10(4), (5) or (6).","g":"/ncc/s43c10"},{"c":"S43C11","t":"Supply of water for fire-fighting purposes","p":"Specification 43 Bushfire protection for certain Class 9 buildings","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/43-bushfire-protection-certain-class-9-buildings#S43C11","x":"Water for fire-fighting purposes must be available and consist of—\na fire hydrant system complying with E1D2, or\na static water supply consisting of tanks, swimming pools, dams or the like, or a combination of these, together with suitable pumps, hoses and fittings, capable of providing the required flow rate for a period of not less than 4 hours, determined in consultation with the relevant fire brigade.","g":"/ncc/s43c11"},{"c":"S43C12","t":"Emergency power supply","p":"Specification 43 Bushfire protection for certain Class 9 buildings","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/43-bushfire-protection-certain-class-9-buildings#S43C12","x":"(1) Emergency power must be provided to support, for not less than 4 hours before and 2 hours after the passing of the fire front during a bushfire event, the ongoing operation of—\nair handling systems to maintain internal tenability; and\nany pumps for fire-fighting; and\nany emergency lighting and exit signs; and\nany other emergency equipment listed in C3D14(6) and required to be provided.\n(2) Manual control for emergency back-up power supply must be provided to facilitate manual intervention where the power supply fails or runs out.","g":"/ncc/s43c12"},{"c":"S43C13","t":"Signage","p":"Specification 43 Bushfire protection for certain Class 9 buildings","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/43-bushfire-protection-certain-class-9-buildings#S43C13","x":"Signage must be provided to warn building occupants against storing combustible materials under or adjacent to the building.","g":"/ncc/s43c13"},{"c":"S43C14","t":"Vehicular access","p":"Specification 43 Bushfire protection for certain Class 9 buildings","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/43-bushfire-protection-certain-class-9-buildings#S43C14","x":"Vehicular access to the building must be provided in accordance C3D5(2), as if the building were a large isolated building for the purposes of C3D4.","g":"/ncc/s43c14"},{"c":"G1O1","t":"Objective","p":"Part G1 Minor structures and components","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g1-minor-structures-and-components#G1O1","x":"The Objective of this Part is to—\nsafeguard people from illness caused by the discharge of swimming pool waste water; and\nprotect other property from damage caused by the discharge of swimming pool waste water; and\nsafeguard young children from drowning or injury in a swimming pool; and\nsafeguard people from drowning or injury due to suction by a swimming pool water recirculation system; and\nsafeguard occupants from illness or injury resulting from being accidentally locked inside spaces which are designed to be entered for short periods of time only and in which occupation for longer periods may be hazardous; and\nsafeguard young children in outdoor play spaces.\nApplications\nG1O1(d) only applies to a swimming pool with a depth of water more than 300 mm.\nG1O1(f) only applies to a Class 9b early childhood centre.","g":"/ncc/g1o1","a19":["GO1"]},{"c":"G1F1","t":"Swimming pool drainage","p":"Part G1 Minor structures and components","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g1-minor-structures-and-components#G1F1","x":"Adequate means for the disposal of swimming pool water and drainage is to be provided to a swimming pool.","g":"/ncc/g1f1","a19":["GF1.1"]},{"c":"G1F2","t":"Swimming pools — access by young children and safety of recirculation systems","p":"Part G1 Minor structures and components","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g1-minor-structures-and-components#G1F2","x":"A swimming pool is to be provided with—\nmeans of restricting access by young children to it; and\nmeans to reduce the possibility of a person being entrapped or injured due to suction by a water recirculation system.\nApplications\nG1F2(b) only applies to a swimming pool with a depth of water more than 300 mm.","g":"/ncc/g1f2","a19":["GF1.2"]},{"c":"G1F3","t":"Accidental locking in small spaces","p":"Part G1 Minor structures and components","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g1-minor-structures-and-components#G1F3","x":"Any refrigerated or cooling chamber, strong-room and vault or the like that is capable of accommodating a person is to have safety measures to facilitate escape and for alerting people outside such a space in the event of an emergency.","g":"/ncc/g1f3","a19":["GF1.3"]},{"c":"G1F4","t":"Early childhood centres","p":"Part G1 Minor structures and components","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g1-minor-structures-and-components#G1F4","x":"An outdoor play space is to be provided with a means of restricting the passage of children to outside of the play space.\nApplications\nG1F4 only applies to a Class 9b early childhood centre.","g":"/ncc/g1f4","a19":["GF1.4"]},{"c":"G1P1","t":"Swimming pool drainage","p":"Part G1 Minor structures and components","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g1-minor-structures-and-components#G1P1","x":"A swimming pool must have adequate means of draining the pool in a manner which will not—\ncause illness to people; or\naffect other property.","g":"/ncc/g1p1","a19":["GP1.1"]},{"c":"G1P2","t":"Swimming pool access and water recirculation systems","p":"Part G1 Minor structures and components","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g1-minor-structures-and-components#G1P2","x":"(1) A barrier must be provided to a swimming pool and must—\nbe continuous for the full extent of the hazard; and\nbe of a strength and rigidity to withstand the foreseeable impact of people; and\nrestrict the access of young children to the pool and the immediate pool surrounds; and\nhave any gates and doors fitted with latching devices not readily operated by young children, and constructed to automatically close and latch.\n(2) A swimming pool water recirculation system must incorporate safety measures to avoid entrapment of, or injury to, a person.\nApplications\nG1P2(2) only applies to a swimming pool with a depth of water more than 300 mm.","g":"/ncc/g1p2","a19":["VIC GP1.2","NSW GP1.2","NT GP1.2","QLD GP1.2","SA GP1.2","TAS GP1.2","GP1.2"]},{"c":"G1P3","t":"Cool rooms","p":"Part G1 Minor structures and components","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g1-minor-structures-and-components#G1P3","x":"Any refrigerated or cooling chamber, or the like which is of sufficient size for a person to enter must—\nhave adequate means of communicating with or alerting other occupants in the building in the case of an emergency; and\nhave a door which is—\nof adequate dimensions to allow occupants to readily escape; and\nopenable from inside without a key at all times.","g":"/ncc/g1p3","a19":["GP1.3"]},{"c":"G1P4","t":"Vaults","p":"Part G1 Minor structures and components","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g1-minor-structures-and-components#G1P4","x":"Any strong-room, vault or the like which is of sufficient size for a person to enter must—\nhave adequate means of communicating with or alerting other occupants in the building in the case of an emergency; and\nhave internal lighting controllable only from within the room; and\nhave an external indicator that the room is occupied.","g":"/ncc/g1p4","a19":["GP1.4"]},{"c":"G1P5","t":"Outdoor play spaces in early childhood centres","p":"Part G1 Minor structures and components","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g1-minor-structures-and-components#G1P5","x":"Fencing or other barriers must be provided around any outdoor play space, in which the design and height of the fencing or other barriers, including the—\ndesign of gates and fittings; and\nproximity of the barriers to any permanent structure on the property,\nmust ensure that children cannot go through, over or under the fencing or other barriers.\nApplications\nG1P5 only applies to a Class 9b early childhood centre.","g":"/ncc/g1p5","a19":["GP1.5"]},{"c":"G1D1","t":"Deemed-to-Satisfy Provisions","p":"Part G1 Minor structures and components","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g1-minor-structures-and-components#G1D1","x":"(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements G1P1 to G1P5 are satisfied by complying with G1D2 to G1D5.\n(2) Where a Performance Solution is proposed, the relevant Performance Requirements must be determined in accordance with A2G2(3) and A2G4(3) as applicable.","g":"/ncc/g1d1","a19":["G1.0"]},{"c":"G1D2","t":"Swimming pools","p":"Part G1 Minor structures and components","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g1-minor-structures-and-components#G1D2","x":"(1) A swimming pool with a depth of water more than 300 mm and which is associated with a Class 2 or 3 building or Class 4 part of a building, must have suitable barriers to restrict access by young children to the immediate pool surrounds in accordance with—\nAS 1926.1, except ‘This clause shall not apply to boundary barriers.’ in clause 2.3.1 is replaced with ‘This clause shall apply to boundary barriers.’; and\nAS 1926.2.\n(2) A water recirculation system in a swimming pool with a depth of water more than 300 mm must comply with AS 1926.3.","g":"/ncc/g1d2","a19":["VIC G1.1","NSW G1.1","SA G1.1","TAS G1.1","G1.1"]},{"c":"G1D3","t":"Refrigerated chambers, strong-rooms and vaults","p":"Part G1 Minor structures and components","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g1-minor-structures-and-components#G1D3","x":"(1) A refrigerated or cooling chamber, strongroom or vault that is of sufficient size for a person to enter must have—\na door which is capable of being opened by hand from inside without a key; and\ninternal lighting controlled only by a switch which is located adjacent to the entrance doorway inside the chamber, strongroom or vault; and\nan indicator lamp positioned outside the chamber, strongroom or vault which is illuminated when the interior lights required by (b) are switched on; and\nan alarm that is—\nlocated outside but controllable only from within the chamber, strongroom or vault; and\nable to achieve a sound pressure level outside the chamber, strongroom or vault of 90 dB(A) when measured 3 m from the sounding device.\n(2) A door required by (1)(a) in a refrigerated or cooling chamber must have a doorway with a clear width of not less than 600 mm and a clear height not less than 1.5 m.","g":"/ncc/g1d3","a19":["G1.2"]},{"c":"G1D4","t":"Outdoor play spaces","p":"Part G1 Minor structures and components","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g1-minor-structures-and-components#G1D4","x":"(1) Any outdoor play space in a Class 9b early childhood centre must be enclosed on all sides with a barrier which—\nwhere the edge of the trafficable surface of the outdoor play space is at the same level or less than 2 m above the surface beneath — complies with AS 1926.1, except ‘This clause shall not apply to boundary barriers.’ in clause 2.3.1 is replaced with ‘This clause shall apply to boundary barriers.’; and\nwhere the edge of the trafficable surface of the outdoor play space is 2 m or more above the surface beneath—\nis not less than 1.8 m high, as measured from above the trafficable surface; and\nis non-climbable and does not contain horizontal or other elements that could facilitate climbing; and\ndoes not have any openings or apertures through which a 100 mm or greater sphere could pass; and\nis not within 1.8 m, as measured directly from the top of the barrier, of any elements within the outdoor play space that facilitate climbing; and\nis not within 900 mm of elements in a wall that facilitate climbing; and\nhas strength and rigidity complying with AS 1926.1.\n(2) For the purposes of (1)(a), AS 1926.1 is applied as if there is a swimming pool located outside the outdoor play space, so that the barrier restricts children from exiting the premises without the knowledge of staff in the centre.\n(3) The requirements of (1) do not apply to a wall, including doors and windows, which form part of the Class 9b early childhood centre, except where the wall is within a non-climbable zone for a barrier provided under (1)(a).","g":"/ncc/g1d4","a19":["G1.3"]},{"c":"G1D5","t":"Swimming pool drainage","p":"Part G1 Minor structures and components","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g1-minor-structures-and-components#G1D5","x":"A swimming pool's pumped discharge must be discharged to the sanitary drainage system in accordance with AS/NZS 3500.2.","g":"/ncc/g1d5"},{"c":"G2O1","t":"Objective","p":"Part G2 Boilers, pressure vessels, heating appliances, fireplaces, chimneys and flues","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g2-boilers-pressure-vessels-heating-appliances-fireplaces-chimneys-and-flues#G2O1","x":"The Objective of this Part is to—\nsafeguard occupants from illness or injury caused by—\nfire from combustion appliances installed within a building; and\nmalfunction of a boiler or pressure vessel installed within a building; and\nprotect a building from damage caused by the malfunction of a boiler or pressure vessel installed within.","g":"/ncc/g2o1","a19":["GO2"]},{"c":"G2F1","t":"Combustion appliances","p":"Part G2 Boilers, pressure vessels, heating appliances, fireplaces, chimneys and flues","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g2-boilers-pressure-vessels-heating-appliances-fireplaces-chimneys-and-flues#G2F1","x":"Combustion appliances using controlled combustion located in a building are to be installed in a way which reduces the likelihood of fire spreading beyond the appliance.","g":"/ncc/g2f1","a19":["GF2.1"]},{"c":"G2F2","t":"Boilers and pressure vessels","p":"Part G2 Boilers, pressure vessels, heating appliances, fireplaces, chimneys and flues","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g2-boilers-pressure-vessels-heating-appliances-fireplaces-chimneys-and-flues#G2F2","x":"Boilers and pressure vessels located in a building are to be installed in a manner which will provide adequate safety for occupants.","g":"/ncc/g2f2","a19":["GF2.2"]},{"c":"G2P1","t":"Combustion heating appliances","p":"Part G2 Boilers, pressure vessels, heating appliances, fireplaces, chimneys and flues","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g2-boilers-pressure-vessels-heating-appliances-fireplaces-chimneys-and-flues#G2P1","x":"Where provided in a building, a combustion appliance and its associated components, including an open fire-place, chimney, flue, chute, hopper or the like, must be installed—\nto withstand the temperatures likely to be generated by the appliance; and\nso that it does not raise the temperature of any building element to a level that would adversely affect the element’s physical or mechanical properties or function; and\nso that hot products of combustion will not—\nescape through the walls of the associated components; and\ndischarge in a position that will cause fire to spread to nearby combustible materials or allow smoke to penetrate through nearby windows, ventilation inlets, or the like.","g":"/ncc/g2p1","a19":["GP2.1"]},{"c":"G2P2","t":"Boilers and pressure vessels","p":"Part G2 Boilers, pressure vessels, heating appliances, fireplaces, chimneys and flues","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g2-boilers-pressure-vessels-heating-appliances-fireplaces-chimneys-and-flues#G2P2","x":"When located in a building, boilers and pressure vessels must be installed to avoid, during reasonably foreseeable conditions, the likelihood of—\nleakage from the vessel which could cause damage to the building; and\nrupture or other mechanical damage of the vessel which could cause damage to the building or injury to occupants.","g":"/ncc/g2p2","a19":["GP2.2"]},{"c":"G2V1","t":"Combustion appliances","p":"Part G2 Boilers, pressure vessels, heating appliances, fireplaces, chimneys and flues","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g2-boilers-pressure-vessels-heating-appliances-fireplaces-chimneys-and-flues#G2V1","x":"Compliance with G2P1(a) and G2P1(b) is verified when—\ncomponents used within an appliance and its installation are constructed from—\nheat-resistant materials for maximum operating temperatures not less than 600℃, where the material complies with (c); or\nheat-tolerant materials for maximum operating temperatures more than 150℃ and less than 600℃, where the material complies with (c); and\nthe building elements surrounding the appliance maintain their designed function and material properties inclusive of a full range of thermal movements when exposed to the heat effects of the appliance; and\na sample of the material is tested to the maximum operating temperature, specified in (a)(i) or (a)(ii) for a minimum of 96 hours; and\nthe tested sample, when allowed to cool, is free from—\nvisible cracks and fractures; and\nvisible indication of de-lamination; and\nlinear distortion in excess of the equivalent of 10 mm per metre, and\ndeterioration of the appearance of any surface finish, when compared to an unheated sample.","g":"/ncc/g2v1","a19":["GV2"]},{"c":"G2D1","t":"Deemed-to-Satisfy Provisions","p":"Part G2 Boilers, pressure vessels, heating appliances, fireplaces, chimneys and flues","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g2-boilers-pressure-vessels-heating-appliances-fireplaces-chimneys-and-flues#G2D1","x":"(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements G2P1 and G2P2 are satisfied by complying with G2D2 to G2D4.\n(2) Where a Performance Solution is proposed, the relevant Performance Requirements must be determined in accordance with A2G2(3) and A2G4(3) as applicable.","g":"/ncc/g2d1","a19":["G2.0"]},{"c":"G2D2","t":"Installation of appliances","p":"Part G2 Boilers, pressure vessels, heating appliances, fireplaces, chimneys and flues","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g2-boilers-pressure-vessels-heating-appliances-fireplaces-chimneys-and-flues#G2D2","x":"The installation of a stove, heater or similar appliance in a building must comply with:\nDomestic solid-fuel burning appliances — installation: AS/NZS 2918.\nFor boilers and pressure vessels: Specification 30.","g":"/ncc/g2d2","a19":["G2.2"]},{"c":"G2D3","t":"Open fireplaces","p":"Part G2 Boilers, pressure vessels, heating appliances, fireplaces, chimneys and flues","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g2-boilers-pressure-vessels-heating-appliances-fireplaces-chimneys-and-flues#G2D3","x":"An open fireplace, or solid-fuel burning appliance in which the fuel-burning compartment is not enclosed, must have—\na hearth constructed of stone, concrete, masonry or similar non-combustible material so that—\nit extends not less than 300 mm beyond the front of the fireplace opening and not less than 150 mm beyond each side of that opening; and\nit extends beyond the limits of the fireplace or appliance not less than 300 mm if the fireplace or appliance is free-standing from any wall of the room; and\nits upper surface does not slope away from the grate or appliance; and\ncombustible material situated below or around the external edge of the hearth, but not below that part required to extend beyond the fireplace opening or the limits of the fireplace, is not less than 150 mm from the upper surface of the hearth; and\nwalls forming the sides and back of the fireplace up to not less than 300 mm above the underside of the arch or lintel which—\nare constructed in 2 separate leaves of solid masonry with a total combined thickness not less than 180 mm, excluding any cavity; and\ndo not consist of concrete block masonry in the construction of the inner leaf; and\nwalls of the chimney above the level referred to in (b)—\nconstructed of masonry units with a net volume, excluding cored and similar holes, not less than 75% of their gross volume, measured on the overall rectangular shape of the units, and with an actual thickness of not less than 100 mm; and\nlined internally to a thickness of not less than 12 mm with rendering consisting of 1 part cement, 3 parts lime, and 10 parts sand by volume, or other suitable material; and\nsuitable damp-proof courses or flashings to maintain weatherproofing.","g":"/ncc/g2d3","a19":["G2.3"]},{"c":"G2D4","t":"Incinerator rooms","p":"Part G2 Boilers, pressure vessels, heating appliances, fireplaces, chimneys and flues","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g2-boilers-pressure-vessels-heating-appliances-fireplaces-chimneys-and-flues#G2D4","x":"(1) If an incinerator is installed in a building, any hopper giving access to a charging chute must be—\nnon-combustible; and\ngas-tight when closed; and\ndesigned to return to the closed position after use; and\nnot attached to a chute that connects directly to a flue unless the hopper is located in the open air; and\nnot located in a required exit.\n(2) A room containing an incinerator must be separated from other parts of the building by construction with an FRL of not less than 60/60/60.","g":"/ncc/g2d4","a19":["G2.4"]},{"c":"G3D1","t":"Application of Part","p":"Part G3 Atrium construction","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g3-atrium-construction#G3D1","x":"This Part does not apply to an atrium which—\nconnects only 2 storeys; or\nconnects only 3 storeys if—\neach storey is provided with a sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17 throughout; and\none of those storeys is situated at a level at which there is direct egress to a road or open space.","g":"/ncc/g3d1","a19":["G3.1"]},{"c":"G3D2","t":"Dimensions of atrium well","p":"Part G3 Atrium construction","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g3-atrium-construction#G3D2","x":"An atrium well must have a width throughout the well that is able to contain a cylinder having a horizontal diameter of not less than 6 m.","g":"/ncc/g3d2","a19":["G3.2"]},{"c":"G3D3","t":"Separation of atrium by bounding walls","p":"Part G3 Atrium construction","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g3-atrium-construction#G3D3","x":"An atrium must be separated from the remainder of the building at each storey by bounding walls set back not more than 3.5 m from the perimeter of the atrium well except in the case of the walls at not more than 3 consecutive storeys if—\none of those storeys is at a level at which direct egress to a road or open space is provided; and\nthe sum of the floor areas of those storeys that are contained within the atrium is not more than the maximum area that is permitted in Table C3D3.","g":"/ncc/g3d3","a19":["G3.3"]},{"c":"G3D4","t":"Construction of bounding walls","p":"Part G3 Atrium construction","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g3-atrium-construction#G3D4","x":"Bounding walls must—\nhave an FRL of not less than 60/60/60, and—\nextend from the floor of the storey to the underside of the floor next above or to the underside of the roof; and\nhave any door openings protected with self-closing or automatic –/60/30 fire doors; or\nbe constructed of fixed toughened safety glass, or wired safety glass in non-combustible frames, with—\nany door openings fitted with a self-closing smoke door complying with Specification 12; and\nthe walls and doors protected with wall-wetting systems in accordance with Specification 31; and\na fire barrier with an FRL of not less than –/60/30 installed in any ceiling spaces above the wall.","g":"/ncc/g3d4","a19":["G3.4"]},{"c":"G3D5","t":"Construction at balconies","p":"Part G3 Atrium construction","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g3-atrium-construction#G3D5","x":"If a bounding wall separating an atrium from the remainder of the building is set back from the perimeter of the atrium well, a barrier that is imperforate, non-combustible, and not less than 1 m high, must be provided.","g":"/ncc/g3d5","a19":["G3.5"]},{"c":"G3D6","t":"Separation at roof","p":"Part G3 Atrium construction","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g3-atrium-construction#G3D6","x":"In an atrium —\nthe roof must have the FRL prescribed in Table S5C11g; or\nthe roof structure and membrane must be protected by a sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17.","g":"/ncc/g3d6","a19":["G3.6"]},{"c":"G3D7","t":"Means of egress","p":"Part G3 Atrium construction","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g3-atrium-construction#G3D7","x":"All areas within an atrium must have access to at least 2 exits.","g":"/ncc/g3d7","a19":["G3.7"]},{"c":"G3D8","t":"Fire and smoke control systems","p":"Part G3 Atrium construction","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g3-atrium-construction#G3D8","x":"Sprinkler systems, smoke control systems, fire detection and alarm systems, and emergency warning and intercom systems must be installed in compliance with Specification 31.","g":"/ncc/g3d8","a19":["G3.8"]},{"c":"G4O1","t":"Objective","p":"Part G4 Construction in alpine areas","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g4-construction-alpine-areas#G4O1","x":"The Objective of this Part is to safeguard occupants in alpine areas from illness or injury from an emergency while evacuating a building.\nApplications\nG4O1 applies to a building constructed in an alpine area.","g":"/ncc/g4o1","a19":["GO4"]},{"c":"G4F1","t":"Construction in alpine areas","p":"Part G4 Construction in alpine areas","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g4-construction-alpine-areas#G4F1","x":"A building in an alpine area is to be provided with additional measures in view of the increased difficulties in fire-fighting and maintaining access and means of egress in snow conditions.\nApplications\nG4F1 only applies to a building constructed in an alpine area.","g":"/ncc/g4f1","a19":["GF4.1"]},{"c":"G4P1","t":"External doorways","p":"Part G4 Construction in alpine areas","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g4-construction-alpine-areas#G4P1","x":"An external doorway from a building in an alpine area must be installed so that opening the door is not obstructed by snow or ice.\nApplications\nG4P1 applies to a building constructed in an alpine area and overrules other Performance Requirements of NCC Volume One.","g":"/ncc/g4p1","a19":["GP4.1"]},{"c":"G4P2","t":"Structures forming pathways in snow conditions","p":"Part G4 Construction in alpine areas","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g4-construction-alpine-areas#G4P2","x":"A building in an alpine area containing external trafficable structures forming part of the means of egress must be constructed so that those structures remain, as far as practicable, useable under snow conditions.\nApplications\nG4P2 applies to a building constructed in an alpine area and overrules other Performance Requirements of NCC Volume One.","g":"/ncc/g4p2","a19":["GP4.2"]},{"c":"G4P3","t":"Control of falling ice and snow","p":"Part G4 Construction in alpine areas","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g4-construction-alpine-areas#G4P3","x":"A building in an alpine area must be constructed so that snow or ice is not shed from the building onto the allotment, any adjoining allotment, road or public space in a location or manner that will—\nobstruct a means of egress from any building to a road or open space; or\notherwise endanger people.\nApplications\nG4P3 applies to a building constructed in an alpine area and overrules other Performance Requirements of NCC Volume One.","g":"/ncc/g4p3","a19":["GP4.3"]},{"c":"G4P4","t":"Fire safety systems in alpine areas","p":"Part G4 Construction in alpine areas","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g4-construction-alpine-areas#G4P4","x":"A building in an alpine area must have a fire safety system installed to—\nfacilitate fire-fighting operations; and\nalert occupants in the event of an emergency.\nApplications\nG4P4 applies to a building constructed in an alpine area and overrules other Performance Requirements of NCC Volume One.","g":"/ncc/g4p4","a19":["GP4.4"]},{"c":"G4D1","t":"Deemed-to-Satisfy Provisions","p":"Part G4 Construction in alpine areas","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g4-construction-alpine-areas#G4D1","x":"(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements G4P1 to G4P4 are satisfied by complying with—\nG4D2 to G4D8; and\nfor a building containing an occupiable outdoor area, Part G6.\n(2) Where a Performance Solution is proposed, the relevant Performance Requirements must be determined in accordance with A2G2(3) and A2G4(3) as applicable.","g":"/ncc/g4d1","a19":["G4.0"]},{"c":"G4D2","t":"Application of Part","p":"Part G4 Construction in alpine areas","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g4-construction-alpine-areas#G4D2","x":"(1) The Deemed-to-Satisfy Provisions of this Part apply to any building constructed in an alpine area in addition to other Deemed-to-Satisfy Provisions of NCC Volume One.\n(2) Where any Deemed-to-Satisfy Provisions are in conflict, the provisions of this Part take precedence.","g":"/ncc/g4d2","a19":["G4.1"]},{"c":"G4D3","t":"External doors","p":"Part G4 Construction in alpine areas","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g4-construction-alpine-areas#G4D3","x":"External doors which may be subject to the build-up of snow must—\nopen inwards or slide; and\nif inward opening, be marked “OPEN INWARDS” on the inside face of the door in letters not less than 75 mm high in a colour contrasting with that of the background; and\nbe constructed so that the threshold is not less than 900 mm above the adjoining surface; and\nif it serves a corridor or stairway, be positioned in an alcove or recess with—\nno horizontal dimensions of the alcove or recess less than twice the width of the door; and\nthe door positioned to open against a wall such that the distance from any part of its swing to the nearest point of entry of the stairway or corridor is not less than the width of the door.","g":"/ncc/g4d3","a19":["G4.3"]},{"c":"G4D4","t":"Emergency lighting","p":"Part G4 Construction in alpine areas","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g4-construction-alpine-areas#G4D4","x":"In a Class 2, 3, 5, 6, 7, 8 or 9 building or Class 4 part of a building, a system of emergency lighting must be installed in accordance with the Deemed-to-Satisfy Provisions of Part E4 —\nin every stairway (other than those within a sole-occupancy unit in a Class 2 or 3 building or Class 4 part of a building); and\nin every public corridor or the like leading to an exit; and\nexternally above every doorway opening to a road or open space; and\nin any storey of the building if illumination sufficient for safe egress will not be available under conditions of emergency.","g":"/ncc/g4d4","a19":["G4.4"]},{"c":"Table G4D5","t":"Alternate stair riser and going dimensions","p":"Part G4 Construction in alpine areas","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g4-construction-alpine-areas#_17217a1b-88a0-4092-b530-55d814a4c7b3","x":"Riser (R) | Going (G) | Slope relationship (2R + G)\nMax | Min | Max | Min | Max | Min\n150 | 115 | 375 | 355 | 675 | 605\nTable Notes\nDimensions are in mm.","tb":"G4D5","g":"/ncc/table-g4d5"},{"c":"G4D5","t":"External trafficable structures","p":"Part G4 Construction in alpine areas","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g4-construction-alpine-areas#G4D5","x":"External stairways, ramps, access bridges or other trafficable structures serving the building must—\nhave a floor surface that consists of expanded mesh if it is used as a means of egress; and\nhave any required barrier designed so that its sides are not less than 75% open; and\nfor a stairway, have goings (G), risers (R) and slope relationship quantity (2R + G) in accordance with—\nTable D3D14; or\nTable G4D5; and\nfor a ramp serving as an exit and not serving as an accessible ramp, have a gradient not steeper than 1:12; and\nwhere a ramp is also serving as an accessible ramp under Part D4, be in accordance with AS 1428.1.\nTable G4D5 Alternate stair riser and going dimensions\nRiser (R)\nGoing (G)\nSlope relationship (2R + G)\nMax\nMin\nMax\nMin\nMax\nMin\n150\n115\n375\n355\n675\n605\nTable Notes\nDimensions are in mm.","g":"/ncc/g4d5","a19":["G4.5"]},{"c":"G4D6","t":"Clear space around buildings","p":"Part G4 Construction in alpine areas","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g4-construction-alpine-areas#G4D6","x":"A building must be so constructed that—\nif any part of an external wall is more than 3.6 m above the natural ground level — the distance of that part from a boundary other than a road alignment is not less than 2.5 m plus an additional 100 mm for each 300 mm or part thereof by which that part of the wall exceeds a height of 3.6 m; and\nif an exit doorway discharges into a court between wings of a building and that area may be used for vehicle access to the building, the distance between wings must be not less than 4 m; and\nwhere an exit doorway discharges opposite a feature that could entrap snow or an embankment that is more than 900 mm above the threshold of the doorway, a distance of not less than 4 m must be provided between the doorway and the feature.","g":"/ncc/g4d6","a19":["G4.6"]},{"c":"G4D7","t":"Fire-fighting services and equipment","p":"Part G4 Construction in alpine areas","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g4-construction-alpine-areas#G4D7","x":"(1) Every Class 2, 3, 5, 6, 7, 8 or 9 building must have—\na manually operated fire alarm system with call-points complying with AS 1670.1; and\nfire hydrants installed in accordance with E1D2(2); and\nfire hose reels installed in accordance with E1D3(2) to (7), except that in a Class 2 or 3 building—\nfor the purpose of E1D3(2), a sole-occupancy unit is considered to be a fire compartment; and\nfor the purpose of E1D3(3)(b), a sole-occupancy unit may be served by a single fire hose reel located at the level of egress from that sole-occupancy unit; and\nfor the purpose of E1D3(6), a fire hose may pass through a doorway in bounding construction referred to in C4D12.\n(2) The requirements of (1)(c) do not apply to a Class 8 electricity network substation.","g":"/ncc/g4d7","a19":["G4.8"]},{"c":"G4D8","t":"Fire orders","p":"Part G4 Construction in alpine areas","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g4-construction-alpine-areas#G4D8","x":"Every Class 2, 3 or 9 building must display a notice clearly marked “FIRE ORDERS” in suitable locations near the main entrance and on each storey, explaining—\nthe method of operation of the fire alarm system and the location of all call-points; and\nthe location and methods of operation of all fire-fighting equipment; and\nthe location of all exits; and\nthe procedure for evacuation of the building.","g":"/ncc/g4d8","a19":["G4.9"]},{"c":"G5O1","t":"Objective","p":"Part G5 Construction in bushfire prone areas","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g5-construction-bushfire-prone-areas#G5O1","x":"The Objective of this Part is to—\nsafeguard occupants from injury from the effects of a bushfire; and\nprotect buildings from the effects of a bushfire; and\nfacilitate temporary shelter for building occupants who may be unable to readily evacuate the building prior to a bushfire.\nApplications\nG5O1(a) and (b) apply in a designated bushfire prone area to—\na Class 2 or 3 building; or\na Class 10a building or deck associated with a Class 2 or 3 building.\nG5O1(a), (b) and (c) apply in a designated bushfire prone area to—\na Class 9a health-care building; and\na Class 9b—\nearly childhood centre; and\nprimary or secondary school; and\na Class 9c residential care building; and\na Class 10a building or deck immediately adjacent or connected to a building of a type listed in (a) to (c).","g":"/ncc/g5o1","a19":["GO5"]},{"c":"G5F1","t":"Construction in bushfire prone areas","p":"Part G5 Construction in bushfire prone areas","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g5-construction-bushfire-prone-areas#G5F1","x":"A building constructed in a designated bushfire prone area —\nis to provide a resistance to bushfires in order to reduce the danger to life and minimise the risk of the loss of the building; and\nif occupied by people who may be unable to readily evacuate the building prior to a bushfire, is to be constructed so as to provide its occupants shelter from the direct and indirect actions of a bushfire.\nApplications\nG5F1(a) applies in a designated bushfire prone area to—\na Class 2 or 3 building; or\na Class 10a building or deck associated with a Class 2 or 3 building; or\na Class 10a building or deck immediately adjacent or connected to a building of a type listed in (2)(a), (b) or (c)\nG5F1(a) and (b) apply in a designated bushfire prone area to—\na Class 9a health-care building; and\na Class 9b—\nearly childhood centre; and\nprimary or secondary school; and\na Class 9c residential care building.","g":"/ncc/g5f1","a19":["GF5.1"]},{"c":"G5P1","t":"Bushfire resistance","p":"Part G5 Construction in bushfire prone areas","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g5-construction-bushfire-prone-areas#G5P1","x":"A building that is constructed in a designated bushfire prone area must be designed and constructed to—\nreduce the risk of ignition from a design bushfire with an annual exceedance probability not more than 1:100 years, or 1:200 years for a Class 9 building; and\ntake account of the assessed duration and intensity of the fire actions of the design bushfire; and\nbe designed to prevent internal ignition of the building and its contents; and\nmaintain the structural integrity of the building for the duration of the design bushfire.\nApplications\nG5P1 applies in a designated bushfire prone area to—\na Class 2 or 3 building; and\na Class 9a health-care building; and\na Class 9b—\nearly childhood centre; and\nprimary or secondary school; and\na Class 9c residential care building; and\na Class 10a building or deck immediately adjacent or connected to a building of a type listed in (a) to (d).","g":"/ncc/g5p1","a19":["GP5.1","NSW GP5.1","QLD GP5.1"]},{"c":"G5P2","t":"Additional bushfire requirements for certain Class 9 buildings","p":"Part G5 Construction in bushfire prone areas","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g5-construction-bushfire-prone-areas#G5P2","x":"A building that is constructed in a designated bushfire prone area and occupied by people who may be unable to readily evacuate the building prior to a bushfire must, to the degree necessary—\nreduce the risk of an untenable indoor environment for occupants during a bushfire event, appropriate to the—\nlocation of the building relative to fire hazards, including—\nclassified vegetation; and\nadjacent buildings, structures and movable objects; and\ncarparking areas and allotment boundaries; and\nother combustible materials; and\nnumber of occupants to be accommodated within the building; and\nintensity of bushfire attack on the building; and\nduration of occupancy; and\nintensity of potential consequential fires; and\noccupant tenability within the building before, during and after the bushfire event; and\ncombined effects of structural, fire exposure and other effects to which the building may reasonably be subjected; and\nprovision of fire fighting equipment and water supply to facilitate protection of the building; and\nbe provided with vehicular access to the site to enable firefighting and emergency personnel to defend or evacuate the building; and\nhave access to a sufficient supply of water for firefighting purposes on the site; and\nprovide safe access within the site to the building (including carparking areas), as well as safe egress after the bushfire event.\nApplications\nG5P2 applies to the following buildings located in a designated bushfire prone area —\na Class 9a health-care building; and\na Class 9b—\nearly childhood centre; and\nprimary or secondary school; and\na Class 9c residential care building.\nNotes\nG5P2 does not guarantee the safety of building occupants or the maintenance of tenable conditions within a building during a bushfire event.","g":"/ncc/g5p2"},{"c":"Table G5V1","t":"Annual Probability of Exceedance (APE) for design bushfire actions","p":"Part G5 Construction in bushfire prone areas","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g5-construction-bushfire-prone-areas#_829453d0-b058-4b2f-adb8-0ec84dc0435d","x":"Importance Level | Complex analysis APE for bushfire exposure | Simple analysis APE for weather conditions (design bushfire)\n1 | No requirement | No requirement\n2 | 1:500 | 1:50\n3 | 1:1000 | 1:100\n4 | 1:2000 | 1:200\nTable Notes\nComplex analysis must consider the probability of ignition, fire spread to the urban interface and penetration of the urban interface coincident with fire weather conditions.","tb":"G5V1","g":"/ncc/table-g5v1"},{"c":"G5V1","t":"Buildings in bushfire prone areas","p":"Part G5 Construction in bushfire prone areas","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g5-construction-bushfire-prone-areas#G5V1","x":"(1) Compliance with Performance Requirement G5P1 is verified if the ignition probability for a building exposed to a design bushfire does not exceed 10%.\n(2) Bushfire design actions must be determined in consideration of the annual probability of a design bushfire derived from—\nassigning the building or structure with an Importance Level in accordance with (3); and\ndetermining the corresponding annual probability of exceedance in accordance with Table G5V1.\n(3) A building or structure's Importance Level must be identified as one of the following:\nImportance Level 1 — where the building or structure presents a low degree of hazard to life and other property in the case of failure.\nImportance Level 2 — where the building or structure is not of Importance Level 1, 3 or 4 or is a Class 2 building accommodating 12 people or less.\nImportance Level 3 — where the building is designed to contain a large number of people and is a—\nClass 2 building accommodating more than 12 people; or\nClass 3 boarding house, guest house, hostel, lodging house or backpackers accommodation; or\nClass 3 residential part of a hotel or motel; or\nClass 3 residential part of a school.\nImportance Level 4 — where the building or structure is—\nessential to emergency management or post-disaster recovery; or\nassociated with hazardous facilities; or\nsubject to a necessary ‘defend in place’ strategy and is a—\nClass 3 accommodation building for the aged, children or people with disabilities; or\nClass 3 residential part of a health-care building which accommodates members of staff; or\nClass 3 residential part of a detention centre; or\nbuilding that operates in the event of a bushfire emergency, such as a public bushfire shelter or a bushfire emergency control centre.\n(4) The ignition probability for a building must be assessed by application of the following:\nAn event tree analysis of relevant bushfire scenarios.\nDesign bushfire conditions that include combinations of the following actions appropriate to the distance between the building and the bushfire hazard:\nDirect attack from airborne burning embers.\nBurning debris and accumulated embers adjacent to a building element.\nRadiant heat from a bushfire front.\nDirect flame attack from a bushfire front.\n(5) Applied fire actions must allow for reasonable variations in—\nfire weather; and\nvegetation, including fuel load, burning behaviour of vegetation (including the potential for crown fires); and\nthe distance of the building from vegetation; and\ntopography, including slopes and features that may shield; and\nignition of adjacent buildings, building elements, plants, mulch and other materials; and\neffective size of fire front; and\nduration of exposure; and\nflame height; and\nflame tilt; and\nflame adhesion to sloping land; and\nthe height of the building and its elements.\n(6) The assessment process must include consideration of—\nthe probability of non-complying construction of critical aspects of an approved design; and\nthe probability of critical aspects of an approved design being fully functional during the life of the building; and\ninclusion of safety factors; and\nsensitivity analysis of critical aspects of a proposed design.\nLimitations\nG5V1 does not apply to a Class 9 building.\nNotes\nFor a building that is subject to G5P2, and therefore outside the scope of G5V1, the building would need to comply with either—\nPerformance Requirement G5P2 by means of a Performance Solution; or\nthe Deemed-to-Satisfy Provisions of G5D4 if the building is located in an area subject to a Bushfire Attack Level (BAL) not exceeding BAL – 12.5.\nTable G5V1 Annual Probability of Exceedance (APE) for design bushfire actions\nImportance Level\nComplex analysis APE for bushfire exposure\nSimple analysis APE for weather conditions (design bushfire)\n1\nNo requirement\nNo requirement\n2\n1:500\n1:50\n3\n1:1000\n1:100\n4\n1:2000\n1:200\nTable Notes\nComplex analysis must consider the probability of ignition, fire spread to the urban interface and penetration of the urban interface coincident with fire weather conditions.","g":"/ncc/g5v1","a19":["GV5"]},{"c":"G5D1","t":"Deemed-to-Satisfy Provisions","p":"Part G5 Construction in bushfire prone areas","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g5-construction-bushfire-prone-areas#G5D1","x":"(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements G5P1 and subject to G5D2, G5P2, are satisfied by complying with G5D3 and G5D4.\n(2) Where a Performance Solution is proposed, the relevant Performance Requirements must be determined in accordance with A2G2(3) and A2G4(3) as applicable.","g":"/ncc/g5d1","a19":["G5.0"]},{"c":"G5D2","t":"Application of Part","p":"Part G5 Construction in bushfire prone areas","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g5-construction-bushfire-prone-areas#G5D2","x":"The Deemed-to-Satisfy Provisions of this Part apply in a designated bushfire prone area to—\na Class 2 or 3 building; or\na building located in an area subject to a Bushfire Attack Level (BAL) not exceeding BAL—12.5, determined in accordance with AS 3959 that is—\na Class 9a health-care building; or\na Class 9b—\nearly childhood centre; or\nprimary or secondary school; or\na Class 9c residential care building; or\na Class 10a building or deck immediately adjacent or connected to a—\nClass 2 or 3 building; or\na building of a type listed in (b).\nNotes\nIf a building of a type listed in (b) or (c)(ii) is subject to a BAL exceeding BAL—12.5, the building would need to comply with Performance Requirement G5P2 by means of a Performance Solution. There are no Deemed-to-Satisfy Provisions for these buildings.","g":"/ncc/g5d2","a19":["G5.1","NSW G5.1","QLD G5.1"]},{"c":"G5D3","t":"Protection — residential buildings","p":"Part G5 Construction in bushfire prone areas","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g5-construction-bushfire-prone-areas#G5D3","x":"In a designated bushfire prone area the following must comply with AS 3959:\nA Class 2 or 3 building.\nA Class 10a building or deck immediately adjacent or connected to a Class 2 or 3 building.","g":"/ncc/g5d3","a19":["NSW G5.2","G5.2"]},{"c":"G5D4","t":"Protection — certain Class 9 buildings","p":"Part G5 Construction in bushfire prone areas","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g5-construction-bushfire-prone-areas#G5D4","x":"(1) In a designated bushfire prone area the following must comply with Specification 43:\nA Class 9a health-care building.\nA Class 9b—\nearly childhood centre; or\nprimary or secondary school.\nA Class 9c residential care building.\n(2) In a designated bushfire prone area, a Class 10a building or deck immediately adjacent or connected to a building of a type listed in (1) must comply with S43C2 and S43C13.","g":"/ncc/g5d4"},{"c":"G6D1","t":"Application of Part","p":"Part G6 Occupiable outdoor areas","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g6-occupiable-outdoor-areas#G6D1","x":"(1) The Deemed-to-Satisfy Provisions of this Part apply to buildings containing an occupiable outdoor area in addition to the other Deemed-to-Satisfy Provisions of NCC Volume One.\n(2) The Deemed-to-Satisfy Provisions of this Part take precedence where there is a difference to the Deemed-to-Satisfy Provisions of Sections C, D, E, F and G.\n(3) Except for G6D2, the Deemed-to-Satisfy Provisions of this Part do not apply to—\nan occupiable outdoor area of a sole-occupancy unit in a Class 2 or 3 building, Class 9c building or Class 4 part of a building; or\nan occupiable outdoor area with an area less than 10m2.","g":"/ncc/g6d1","a19":["G6.1"]},{"c":"G6D2","t":"Fire hazard properties","p":"Part G6 Occupiable outdoor areas","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g6-occupiable-outdoor-areas#G6D2","x":"(1) Subject to (2), a lining, material or assembly in an occupiable outdoor area must comply with C2D11 as for an internal element.\n(2) The following fire hazard properties of a lining, material or assembly in an occupiable outdoor area are not required to comply with C2D11:\nAverage specific extinction area.\nSmoke-Developed Index.\nSmoke development rate.\nSmoke growth rate index (SMOGRARC).","g":"/ncc/g6d2","a19":["G6.2"]},{"c":"G6D3","t":"Fire separation","p":"Part G6 Occupiable outdoor areas","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g6-occupiable-outdoor-areas#G6D3","x":"For the purposes of the Deemed-to-Satisfy Provisions of C3D8, C3D9 and C3D10, a reference to a storey includes an occupiable outdoor area, however a fire wall cannot be used to separate an occupiable outdoor area into different fire compartments.","g":"/ncc/g6d3","a19":["G6.3"]},{"c":"G6D4","t":"Provision for escape","p":"Part G6 Occupiable outdoor areas","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g6-occupiable-outdoor-areas#G6D4","x":"For the purposes of the Deemed-to-Satisfy Provisions of Part D2, a reference to a storey or room includes an occupiable outdoor area.","g":"/ncc/g6d4","a19":["G6.4"]},{"c":"G6D5","t":"Construction of exits","p":"Part G6 Occupiable outdoor areas","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g6-occupiable-outdoor-areas#G6D5","x":"For the purposes of the Deemed-to-Satisfy Provisions of Part D3, a reference to a storey or room includes an occupiable outdoor area.","g":"/ncc/g6d5","a19":["G6.5"]},{"c":"G6D6","t":"Fire fighting equipment","p":"Part G6 Occupiable outdoor areas","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g6-occupiable-outdoor-areas#G6D6","x":"Except for S17C7(2)(a), for the purposes of the Deemed-to-Satisfy Provisions of Part E1, a reference to a storey includes an occupiable outdoor area.\nNotes\nAn occupiable outdoor area is not a storey for the purposes of Schedule 1 of the NCC and therefore is not included in the determination of rise in storeys.","g":"/ncc/g6d6","a19":["G6.6"]},{"c":"G6D7","t":"Lift installations","p":"Part G6 Occupiable outdoor areas","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g6-occupiable-outdoor-areas#G6D7","x":"For the purposes of the Deemed-to-Satisfy Provisions of Part E3, a reference to a storey includes an occupiable outdoor area.","g":"/ncc/g6d7","a19":["G6.7"]},{"c":"G6D8","t":"Visibility in an emergency, exit signs and warning systems","p":"Part G6 Occupiable outdoor areas","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g6-occupiable-outdoor-areas#G6D8","x":"For the purposes of the Deemed-to-Satisfy Provisions of Part E4, a reference to a storey includes an occupiable outdoor area.","g":"/ncc/g6d8","a19":["G6.8"]},{"c":"G6D9","t":"Light and ventilation","p":"Part G6 Occupiable outdoor areas","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g6-occupiable-outdoor-areas#G6D9","x":"For the purposes of the Deemed-to-Satisfy Provisions of F6D5, F6D9 and F6D10, a reference to a room includes an occupiable outdoor area.","g":"/ncc/g6d9","a19":["G6.9"]},{"c":"G6D10","t":"Fire orders","p":"Part G6 Occupiable outdoor areas","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g6-occupiable-outdoor-areas#G6D10","x":"For the purposes of the Deemed-to-Satisfy Provisions of G4D8, a reference to a storey includes an occupiable outdoor area.","g":"/ncc/g6d10","a19":["G6.10"]},{"c":"G7O1","t":"Objective","p":"Part G7 Livable housing design","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g7-livable-housing-design#G7O1","x":"The Objective of this Part is to ensure that housing is designed to meet the needs of the community, including older people and those with a mobility-related disability.\nApplications\nG7O1 only applies to a Class 2 sole-occupancy unit.","g":"/ncc/g7o1"},{"c":"G7F1","t":"Livable housing design","p":"Part G7 Livable housing design","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g7-livable-housing-design#G7F1","x":"A Class 2 sole-occupancy unit is to be designed such that it is—\neasy to enter; and\neasy to navigate in and around; and\ncapable of easy and cost effective adaptation; and\nresponsive to the changing needs of occupants.\nApplications\nG7F1 only applies to a Class 2 sole-occupancy unit.","g":"/ncc/g7f1"},{"c":"G7P1","t":"Livable housing design","p":"Part G7 Livable housing design","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g7-livable-housing-design#G7P1","x":"Each sole-occupancy unit in a Class 2 building must be provided with—\nat least one level and step-free entrance door into the sole-occupancy unit from an accessible part of the floor on which it is located; and\ninternal doors and corridors which facilitate unimpeded movement between spaces; and\na sanitary compartment that—\nfacilitates independent access and use; and\nis located on the entry level of the sole-occupancy unit; and\na shower that facilitates independent access and use; and\nthe walls of a sanitary compartment referred to in (c), the shower referred to in (d) and a bath (where installed, other than a freestanding bath) constructed so as to facilitate future installation of grabrails, or the like, in a way that minimises the removal of existing wall linings.\nApplications\nG7P1(a) only applies to a sole-occupancy unit that is located on an accessible floor.","g":"/ncc/g7p1"},{"c":"G7D1","t":"Deemed-to-Satisfy Provisions","p":"Part G7 Livable housing design","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g7-livable-housing-design#G7D1","x":"(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirement G7P1 is satisfied by complying with G7D2.\n(2) Where a Performance Solution is proposed, the relevant Performance Requirements must be determined in accordance with A2G2(3) and A2G4(3) as applicable.","g":"/ncc/g7d1"},{"c":"G7D2","t":"Livable housing design","p":"Part G7 Livable housing design","u":"/editions/ncc-2025/adopted/volume-one/g-ancillary-provisions/part-g7-livable-housing-design#G7D2","x":"Each sole-occupancy unit in a Class 2 building must comply with the ABCB Standard for Livable Housing Design, except for Part 1.","g":"/ncc/g7d2"},{"c":"S32C1","t":"Scope","p":"Specification 32 Construction of proscenium walls","u":"/editions/ncc-2025/adopted/volume-one/i-special-use-buildings/32-construction-proscenium-walls#S32C1","x":"This Specification contains the requirements for the construction of proscenium walls for theatres, public halls, or the like.","g":"/ncc/s32c1","a19":["Spec H1.3: 1"]},{"c":"S32C2","t":"Separation of stage areas, etc","p":"Specification 32 Construction of proscenium walls","u":"/editions/ncc-2025/adopted/volume-one/i-special-use-buildings/32-construction-proscenium-walls#S32C2","x":"(1) Dressing rooms, scene docks, property rooms, workshops, associated store rooms and other ancillary areas must be—\nlocated on the stage side of the proscenium wall; and\nseparated from corridors and the like by construction having an FRL of not less than 60/60/60, and if of lightweight construction, complying with Specification 6.\n(2) The stage and backstage must be separated from other parts of the building other than the audience seating area by construction having an FRL of not less than 60/60/60, and if of lightweight construction, complying with Specification 6.\n(3) Any doorway in the construction referred to in (1) and (2) must be protected by a self-closing –/60/30 fire door.","g":"/ncc/s32c2","a19":["Spec H1.3: 2"]},{"c":"S32C3","t":"Proscenium wall construction","p":"Specification 32 Construction of proscenium walls","u":"/editions/ncc-2025/adopted/volume-one/i-special-use-buildings/32-construction-proscenium-walls#S32C3","x":"A proscenium wall must—\nextend to the underside of the roof covering or the underside of the structural floor next above; and\nhave an FRL of not less than 60/60/60, and if of lightweight construction, comply with Specification 6.","g":"/ncc/s32c3","a19":["Spec H1.3: 3"]},{"c":"S32C4","t":"Combustible materials not to cross proscenium wall","p":"Specification 32 Construction of proscenium walls","u":"/editions/ncc-2025/adopted/volume-one/i-special-use-buildings/32-construction-proscenium-walls#S32C4","x":"Timber purlins or other combustible material must not pass through or cross any proscenium wall.","g":"/ncc/s32c4","a19":["Spec H1.3: 4"]},{"c":"S32C5","t":"Protection of openings in proscenium wall","p":"Specification 32 Construction of proscenium walls","u":"/editions/ncc-2025/adopted/volume-one/i-special-use-buildings/32-construction-proscenium-walls#S32C5","x":"Every opening in a proscenium wall must be protected—\nat the principal opening, by a curtain in accordance with S32C6 which is—\ncapable of closing the proscenium opening within 35 seconds either by gravity slide or motor assisted mechanisms; and\noperated by a system of automatic heat activated devices, manually operated devices or push button emergency devices; and\nable to be operated from either the stage side or the audience side of the curtain; and\nat any doorway in the wall, by a self-closing –/60/30 fire door.","g":"/ncc/s32c5","a19":["Spec H1.3: 5"]},{"c":"S32C6","t":"Proscenium curtains","p":"Specification 32 Construction of proscenium walls","u":"/editions/ncc-2025/adopted/volume-one/i-special-use-buildings/32-construction-proscenium-walls#S32C6","x":"A curtain required by S32C5 must be—\na fire safety curtain—\nmade of non-combustible material; and\ncapable of withstanding a pressure differential of 0.5 kPa over its entire surface area; and\nso fitted that when fully lowered it inhibits the penetration of smoke around the perimeter of the opening, from the stage; or\na curtain—\nhaving fire hazard properties complying with Specification 7; and\nprotected by a deluge system of open sprinklers installed along the full width of the curtain.","g":"/ncc/s32c6","a19":["Spec H1.3: 6"]},{"c":"I1D1","t":"Application of Part","p":"Part I1 Class 9b buildings","u":"/editions/ncc-2025/adopted/volume-one/i-special-use-buildings/part-i1-class-9b-buildings#I1D1","x":"(1) The Deemed-to-Satisfy Provisions of this Part apply to every enclosed Class 9b building or part of a building which—\nis a school assembly, church or community hall with a stage and any backstage area with a total floor area of more than 300 m2; or\notherwise, has a stage and any backstage area with a total floor area of more than 200 m2; or\nhas a stage with an associated rigging loft.\n(2) Notwithstanding (1)—\nI1D4 applies to every open or enclosed Class 9b building; and\nI1D7 applies to every enclosed Class 9b building.","g":"/ncc/i1d1","a19":["NSW H1.1","H1.1"]},{"c":"I1D2","t":"Separation","p":"Part I1 Class 9b buildings","u":"/editions/ncc-2025/adopted/volume-one/i-special-use-buildings/part-i1-class-9b-buildings#I1D2","x":"A theatre, public hall or the like must—\nhave a sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17; or\nhave the stage, backstage area and accessible under stage area separated from the audience by a proscenium wall in accordance with I1D3.","g":"/ncc/i1d2","a19":["H1.2"]},{"c":"I1D3","t":"Proscenium wall construction","p":"Part I1 Class 9b buildings","u":"/editions/ncc-2025/adopted/volume-one/i-special-use-buildings/part-i1-class-9b-buildings#I1D3","x":"A proscenium wall must comply with Specification 32.","g":"/ncc/i1d3","a19":["H1.3"]},{"c":"I1D4","t":"Seating area","p":"Part I1 Class 9b buildings","u":"/editions/ncc-2025/adopted/volume-one/i-special-use-buildings/part-i1-class-9b-buildings#I1D4","x":"In a seating area—\nthe gradient of the floor surface must not be steeper than 1 in 8, or the floor must be stepped so that—\na line joining the nosings of consecutive steps does not exceed an angle of 30° to the horizontal; and\nthe height of each step in the stepped floor is not more than 600 mm; and\nthe height of any opening in such a step is not more than 125 mm; and\nif an aisle divides the stepped floor and the difference in level between any 2 consecutive steps—\nexceeds 230 mm but not 400 mm — an intermediate step must be provided in the aisle; and\nexceeds 400 mm — 2 equally spaced intermediate steps must be provided in the aisle; and\nthe going of intermediate steps must be not less than 270 mm and such as to provide as nearly as practicable equal treads throughout the length of the aisle; and\nthe clearance between rows of fixed seats used for viewing performing arts, sport or recreational activities must be not less than—\n300 mm if the distance to an aisle is not more than 3.5 m; or\n500 mm if the distance to an aisle is more than 3.5 m.","g":"/ncc/i1d4","a19":["H1.4"]},{"c":"I1D5","t":"Exits from stages","p":"Part I1 Class 9b buildings","u":"/editions/ncc-2025/adopted/volume-one/i-special-use-buildings/part-i1-class-9b-buildings#I1D5","x":"(1) The path of travel to an exit from a stage or performing area must not pass through the proscenium wall if the stage area is separated from the audience area with a proscenium wall.\n(2) Required exits from backstage and under-stage areas must be independent of those provided for the audience area.","g":"/ncc/i1d5","a19":["H1.5"]},{"c":"I1D6","t":"Access to platforms and lofts","p":"Part I1 Class 9b buildings","u":"/editions/ncc-2025/adopted/volume-one/i-special-use-buildings/part-i1-class-9b-buildings#I1D6","x":"A stairway that provides access to a service platform, rigging loft, or the like, must comply with AS 1657.","g":"/ncc/i1d6","a19":["H1.6"]},{"c":"I1D7","t":"Aisle lights","p":"Part I1 Class 9b buildings","u":"/editions/ncc-2025/adopted/volume-one/i-special-use-buildings/part-i1-class-9b-buildings#I1D7","x":"In every enclosed Class 9b building, where in any part of the auditorium, the general lighting is dimmed or extinguished during public occupation and the floor is stepped or is inclined at a slope steeper than 1 in 12, aisle lights must be provided to illuminate the full length of the aisle and tread of each step.","g":"/ncc/i1d7","a19":["H1.7"]},{"c":"I2D1","t":"Application of Part","p":"Part I2 Public transport buildings","u":"/editions/ncc-2025/adopted/volume-one/i-special-use-buildings/part-i2-public-transport-buildings#I2D1","x":"(1) The Deemed-to-Satisfy Provisions of this Part apply to the passenger use areas of a Class 9b or Class 10 building used for public transport.\n(2) The Deemed-to-Satisfy Provisions of this Part take precedence where there is a difference to the Deemed-to-Satisfy Provisions of Parts D4, E3 and F4.\n(3) For an airport that does not accept regular public transport services, as defined in the Disability Standards for Accessible Public Transport 2002, only I2D8, I2D9, I2D10, I2D11, I2D12 and I2D13 of this Part apply.\n(4) Exemption (1) to A6G1(1) does not apply to this Part.","g":"/ncc/i2d1","a19":["H2.1"]},{"c":"I2D2","t":"Accessways","p":"Part I2 Public transport buildings","u":"/editions/ncc-2025/adopted/volume-one/i-special-use-buildings/part-i2-public-transport-buildings#I2D2","x":"(1) An accessway must comply with AS 1428.2.\n(2) If an accessway branches into 2 or more parallel tracks—\nthe ends of each track must be on the main pedestrian traffic routes; and\nthe parallel tracks must have equal convenience and be located as close as practicable to the main pedestrian branch.\n(3) The minimum unobstructed width of an accessway must be 1.2 m, except that—\nthe minimum unobstructed width of a moving walkway forming part of an accessway may be not less than 850 mm; and\nthe minimum unobstructed width of a doorway in an accessway may be not less than 850 mm.\n(4) Poles, columns, stanchions, bollards and fixtures must not project into an accessway.\n(5) Obstacles that abut an accessway must have a luminance contrast with a background of not less than 30%.\n(6) Manoeuvring areas that allow a 180 degree wheelchair turn must comply with clause 6.2 of AS 1428.2.\n(7) A passing area must be provided at least every 6 m along any two-way accessway that is less than 1800 mm wide.\n(8) Ground and floor surfaces must comply with clause 9 of AS 1428.2 and AS 1428.1 Supplement 1 provides criteria for the selection of floor surfaces.\n(9) The requirements of D4D4(c)(ii) do not apply to Class 9b or Class 10 public transport buildings.","g":"/ncc/i2d2","a19":["H2.2"]},{"c":"I2D3","t":"Ramps","p":"Part I2 Public transport buildings","u":"/editions/ncc-2025/adopted/volume-one/i-special-use-buildings/part-i2-public-transport-buildings#I2D3","x":"(1) A ramp forming part of an accessway must comply with clause 8 of AS 1428.2.\n(2) The requirements of D4D12(a) do not apply to Class 9b or Class 10 public transport buildings.","g":"/ncc/i2d3","a19":["H2.3"]},{"c":"I2D4","t":"Handrails and grabrails","p":"Part I2 Public transport buildings","u":"/editions/ncc-2025/adopted/volume-one/i-special-use-buildings/part-i2-public-transport-buildings#I2D4","x":"(1) A handrail must comply with clause 10.1 of AS 1428.2.\n(2) Handrails must be placed along an accessway wherever passengers are likely to require additional support or passive guidance.\n(3) A grabrail must comply with clause 10.2 of AS 1428.2.\n(4) A grabrail or handrail must be provided at fixed locations where passengers are required to pay fares.","g":"/ncc/i2d4","a19":["H2.4"]},{"c":"I2D5","t":"Doorways and doors","p":"Part I2 Public transport buildings","u":"/editions/ncc-2025/adopted/volume-one/i-special-use-buildings/part-i2-public-transport-buildings#I2D5","x":"Doorways and doors must comply with clause 11 (except clause 11.5.2) of AS 1428.2.","g":"/ncc/i2d5","a19":["H2.5"]},{"c":"I2D6","t":"Lifts","p":"Part I2 Public transport buildings","u":"/editions/ncc-2025/adopted/volume-one/i-special-use-buildings/part-i2-public-transport-buildings#I2D6","x":"Lift facilities must comply with AS 1735.12.","g":"/ncc/i2d6","a19":["H2.6"]},{"c":"I2D7","t":"Stairways","p":"Part I2 Public transport buildings","u":"/editions/ncc-2025/adopted/volume-one/i-special-use-buildings/part-i2-public-transport-buildings#I2D7","x":"Stairs must comply with—\nclause 9.1 of AS 1428.1, including the notes; and\nclause 9.2 of AS 1428.1; and\nclauses 13.2, 13.3 and Figures 8 and 9 of AS 1428.2.","g":"/ncc/i2d7","a19":["H2.7"]},{"c":"I2D8","t":"Unisex accessible toilet","p":"Part I2 Public transport buildings","u":"/editions/ncc-2025/adopted/volume-one/i-special-use-buildings/part-i2-public-transport-buildings#I2D8","x":"If toilets are provided, there must be at least one unisex accessible toilet without an airlock that complies with AS 1428.1 clause 10, sanitary facilities.","g":"/ncc/i2d8","a19":["H2.8"]},{"c":"I2D9","t":"Location of accessible toilets","p":"Part I2 Public transport buildings","u":"/editions/ncc-2025/adopted/volume-one/i-special-use-buildings/part-i2-public-transport-buildings#I2D9","x":"Accessible toilets must be in the same location as other toilets.","g":"/ncc/i2d9","a19":["H2.9"]},{"c":"I2D10","t":"Symbols and signs","p":"Part I2 Public transport buildings","u":"/editions/ncc-2025/adopted/volume-one/i-special-use-buildings/part-i2-public-transport-buildings#I2D10","x":"(1) The international symbols for accessibility and deafness in accordance with clauses 14.2 and 14.3 of AS 1428.1 must be used to identify an accessway and which facilities and boarding points are accessible.\n(2) Signs must be placed in accordance with clause 17.4 of AS 1428.2.\n(3) The size of accessibility symbols must comply with Table 1 of AS 1428.2.\n(4) The symbol for accessibility must incorporate directional arrows and words or, if possible, pictograms, to show passengers the way to accessible facilities such as toilets.\n(5) Signs must comply with clause 17.1 and Figure 30 of AS 1428.2.\n(6) If a sign incorporates raised lettering or symbols, they must be at least 0.8 mm above the surface of the sign.\n(7) If an operator or provider supplements a notice with braille characters, they must be placed to the left of the raised characters.","g":"/ncc/i2d10","a19":["H2.10"]},{"c":"I2D11","t":"Tactile ground surface indicators","p":"Part I2 Public transport buildings","u":"/editions/ncc-2025/adopted/volume-one/i-special-use-buildings/part-i2-public-transport-buildings#I2D11","x":"Tactile ground surface indicators must be installed in accordance with AS 1428.4 on an accessway and must indicate changes of direction in accordance with clause 18.1 of AS 1428.2.","g":"/ncc/i2d11","a19":["H2.11"]},{"c":"I2D12","t":"Lighting","p":"Part I2 Public transport buildings","u":"/editions/ncc-2025/adopted/volume-one/i-special-use-buildings/part-i2-public-transport-buildings#I2D12","x":"Any lighting provided must comply with minimum levels of maintenance illumination for various situations shown in the notes to clause 19.1 of AS 1428.2.","g":"/ncc/i2d12","a19":["H2.12"]},{"c":"I2D13","t":"Hearing augmentation","p":"Part I2 Public transport buildings","u":"/editions/ncc-2025/adopted/volume-one/i-special-use-buildings/part-i2-public-transport-buildings#I2D13","x":"If a public address system is installed, it must comply with clause 21.1 of AS 1428.2.","g":"/ncc/i2d13","a19":["H2.13"]},{"c":"I2D14","t":"Emergency warning systems","p":"Part I2 Public transport buildings","u":"/editions/ncc-2025/adopted/volume-one/i-special-use-buildings/part-i2-public-transport-buildings#I2D14","x":"(1) If an emergency warning system is installed, it must comply with clauses 18.2.1, 18.2.2 and 18.2.3 of AS 1428.2.\n(2) In the event of an emergency, provision must be made for people with vision impairment to locate the exit path.","g":"/ncc/i2d14","a19":["H2.14"]},{"c":"I2D15","t":"Controls","p":"Part I2 Public transport buildings","u":"/editions/ncc-2025/adopted/volume-one/i-special-use-buildings/part-i2-public-transport-buildings#I2D15","x":"Controls must comply with clause 11 of AS 1428.1.","g":"/ncc/i2d15","a19":["H2.15"]},{"c":"I3D1","t":"Application of Part","p":"Part I3 Farm buildings and farm sheds","u":"/editions/ncc-2025/adopted/volume-one/i-special-use-buildings/part-i3-farm-buildings-and-farm-sheds#I3D1","x":"(1) The Deemed-to-Satisfy Provisions of this Part apply to farm buildings and farm sheds.\n(2) The Deemed-to-Satisfy Provisions of this Part take precedence where there is a difference to the Deemed-to-Satisfy Provisions of Sections C, D, E, and F.\n(3) I3D1 to I3D5, I3D8 and I3D11 to I3D18 apply to a farm shed.\n(4) I3D1, I3D3, I3D5 to I3D7, I3D9 to I3D12, I3D14, I3D15 and I3D18 apply to a farm building.","g":"/ncc/i3d1","a19":["SA H3.1","H3.1"]},{"c":"I3D2","t":"Fire resistance and separation","p":"Part I3 Farm buildings and farm sheds","u":"/editions/ncc-2025/adopted/volume-one/i-special-use-buildings/part-i3-farm-buildings-and-farm-sheds#I3D2","x":"A farm shed need not comply with the provisions of Parts C2, C3 and C4, except for C2D12, if it is separated from any other building or allotment boundary by a distance of not less than 6 m.","g":"/ncc/i3d2","a19":["H3.2"]},{"c":"I3D3","t":"Provision for escape","p":"Part I3 Farm buildings and farm sheds","u":"/editions/ncc-2025/adopted/volume-one/i-special-use-buildings/part-i3-farm-buildings-and-farm-sheds#I3D3","x":"(1) Except for D2D3, D2D5 to D2D11, D2D14, D2D15(1), D2D18(c), D2D19 and D2D20, the Deemed-to-Satisfy Provisions of Part D2 do not apply to a farm shed.\n(2) An open space adjacent to a farm building or a farm shed need not be directly connected with a public road.","g":"/ncc/i3d3","a19":["H3.3"]},{"c":"I3D4","t":"Construction of exits","p":"Part I3 Farm buildings and farm sheds","u":"/editions/ncc-2025/adopted/volume-one/i-special-use-buildings/part-i3-farm-buildings-and-farm-sheds#I3D4","x":"Except for D3D14, D3D15, D3D17 to D3D21, D3D22 and D3D29, the Deemed-to-Satisfy Provisions of Part D3 do not apply to a farm shed.","g":"/ncc/i3d4","a19":["H3.4"]},{"c":"I3D5","t":"Fixed platforms, walkways, stairways and ladders","p":"Part I3 Farm buildings and farm sheds","u":"/editions/ncc-2025/adopted/volume-one/i-special-use-buildings/part-i3-farm-buildings-and-farm-sheds#I3D5","x":"A fixed platform, stairway, ladder and any going and riser, landing, handrail or barrier may comply with AS 1657 in lieu of D3D14, D3D15, D3D17 to D3D21 and D3D22 where it serves a farm building or a farm shed.","g":"/ncc/i3d5","a19":["H3.5"]},{"c":"I3D6","t":"Thresholds","p":"Part I3 Farm buildings and farm sheds","u":"/editions/ncc-2025/adopted/volume-one/i-special-use-buildings/part-i3-farm-buildings-and-farm-sheds#I3D6","x":"The threshold of a doorway that serves an area not required to be accessible by D4D2 in a farm building need not comply with D3D16 where the door sill is not more than 700 mm above the finished surface of the ground, floor or the like, to which the doorway opens.","g":"/ncc/i3d6","a19":["H3.6"]},{"c":"I3D7","t":"Swinging doors","p":"Part I3 Farm buildings and farm sheds","u":"/editions/ncc-2025/adopted/volume-one/i-special-use-buildings/part-i3-farm-buildings-and-farm-sheds#I3D7","x":"A swinging door in a required exit or forming part of a required exit need not swing in the direction of egress if it serves a farm building.","g":"/ncc/i3d7","a19":["H3.7"]},{"c":"I3D8","t":"Fire fighting equipment","p":"Part I3 Farm buildings and farm sheds","u":"/editions/ncc-2025/adopted/volume-one/i-special-use-buildings/part-i3-farm-buildings-and-farm-sheds#I3D8","x":"The Deemed-to-Satisfy Provisions of Part E1 do not apply to a farm shed.","g":"/ncc/i3d8","a19":["H3.8"]},{"c":"I3D9","t":"Fire hydrants and water supplies","p":"Part I3 Farm buildings and farm sheds","u":"/editions/ncc-2025/adopted/volume-one/i-special-use-buildings/part-i3-farm-buildings-and-farm-sheds#I3D9","x":"(1) This provision applies to a farm building —\nwith a total floor area greater than 500 m2; and\nlocated where a fire brigade station is—\nnot more than 50 km from the building as measured along roads; and\nequipped with equipment capable of utilising a fire hydrant.\n(2) A farm building referred to in (1) must be—\nprovided with a fire hydrant system installed in accordance with AS 2419.1, except reference to ‘4 hours’ water supply in clause 4.2 is replaced with ‘2 hours’; or\nlocated on the same allotment as an access point to a water supply which—\nhas a minimum total capacity of 144,000 litres; and\nis situated so as to enable emergency services vehicles access to within 4 m; and\nis located within 60 m of the building and not more than 90 m from any part of the building.\n(3) For the purposes of (2)(b), water supply for a farm building must consist of one or any number of the following:\nA water storage tank.\nA dam.\nA reservoir.\nA river.\nA lake.\nA bore.\nA sea.\n(4) If the whole or part of the water supply referred to in (2)(b) is contained in a water storage tank, it must be—\nlocated not less than 10 m from the building; and\nfitted with at least one small bore suction connection and one large bore suction connection where—\neach suction connection is located in a position so as to enable emergency service vehicles access to within 4 m; and\nthe suction connections are located not less than 10 m from the building; and\n‘small bore suction connection’ and ‘large bore suction connection’ have the meanings contained in AS 2419.1.","g":"/ncc/i3d9","a19":["H3.9"]},{"c":"I3D10","t":"Fire hose reels","p":"Part I3 Farm buildings and farm sheds","u":"/editions/ncc-2025/adopted/volume-one/i-special-use-buildings/part-i3-farm-buildings-and-farm-sheds#I3D10","x":"A fire hose reel system need not be provided to serve a farm building where portable fire extinguishers are installed in accordance with I3D11.","g":"/ncc/i3d10","a19":["H3.10"]},{"c":"I3D11","t":"Portable fire extinguishers","p":"Part I3 Farm buildings and farm sheds","u":"/editions/ncc-2025/adopted/volume-one/i-special-use-buildings/part-i3-farm-buildings-and-farm-sheds#I3D11","x":"(1) A farm building not provided with a fire hose reel system in accordance with E1D3 must be provided with—\none portable fire extinguisher rated at not less than 5ABE in each room containing flammable materials or electrical equipment; and\none portable fire extinguisher rated at not less than 4A60BE adjacent to every required exit door; and\nlocation signs complying with clauses 3.3 to 3.9 of AS 2444 above each required portable fire extinguisher.\n(2) A farm shed must be provided with not less than one portable fire extinguisher for every 500 m2 of floor area or part thereof, distributed as evenly as practicable throughout the building.\n(3) A portable fire extinguisher required by (2) must be—\nof ABE type; and\nnot less than 4.5 kg in size; and\ninstalled in accordance with Section 3 of AS 2444.","g":"/ncc/i3d11","a19":["H3.11"]},{"c":"I3D12","t":"Emergency lighting requirements","p":"Part I3 Farm buildings and farm sheds","u":"/editions/ncc-2025/adopted/volume-one/i-special-use-buildings/part-i3-farm-buildings-and-farm-sheds#I3D12","x":"(1) An emergency lighting system need not be installed in a farm building —\nwith no artificial lighting as permitted by I3D18; or\nwith artificial lighting where, if that lighting fails due to an emergency, automatic power supply to the building is provided by a fuel-driven generator.\n(2) An emergency lighting system need not be installed in a farm shed.","g":"/ncc/i3d12","a19":["H3.12"]},{"c":"I3D13","t":"Exit signs","p":"Part I3 Farm buildings and farm sheds","u":"/editions/ncc-2025/adopted/volume-one/i-special-use-buildings/part-i3-farm-buildings-and-farm-sheds#I3D13","x":"An exit serving a farm shed need not be provided with an exit sign where the exit is a permanent opening not less than 2 m wide.","g":"/ncc/i3d13","a19":["H3.13"]},{"c":"I3D14","t":"Direction signs","p":"Part I3 Farm buildings and farm sheds","u":"/editions/ncc-2025/adopted/volume-one/i-special-use-buildings/part-i3-farm-buildings-and-farm-sheds#I3D14","x":"In a farm building or a farm shed, if an exit is not readily apparent to persons occupying or visiting the building, exit signs complying with I3D15 must be installed in appropriate positions in corridors, hallways, lobbies and the like, indicating the direction to a required exit.","g":"/ncc/i3d14","a19":["H3.14"]},{"c":"I3D15","t":"Design and operation of exit signs","p":"Part I3 Farm buildings and farm sheds","u":"/editions/ncc-2025/adopted/volume-one/i-special-use-buildings/part-i3-farm-buildings-and-farm-sheds#I3D15","x":"(1) In a farm building, each required exit sign provided under E4D5 and I3D14 need not comply with E4D8 if—\nthe use of illuminated exit signs may adversely impact the behaviour or welfare of animals being kept in the building; and\nnon-illuminated exit signs are installed in accordance with the requirements of Appendix D of AS/NZS 2293.1 as for an externally illuminated exit sign, and clauses 5.6 and 5.8 of AS/NZS 2293.1.\n(2) In a farm shed, each required exit sign provided under E4D5 and I3D14 need not comply with E4D8 if—\nnon-illuminated exit signs are installed in accordance with the requirements of Appendix D of AS/NZS 2293.1 as for an externally illuminated exit sign, and clauses 5.6 and 5.8 of AS/NZS 2293.1; and\nthe maximum viewing distance in clause 5.6 of AS/NZS 2293.1 is not more than 24 m.","g":"/ncc/i3d15","a19":["H3.15"]},{"c":"I3D16","t":"Sanitary facilities","p":"Part I3 Farm buildings and farm sheds","u":"/editions/ncc-2025/adopted/volume-one/i-special-use-buildings/part-i3-farm-buildings-and-farm-sheds#I3D16","x":"F4D4 does not apply to a farm shed.","g":"/ncc/i3d16","a19":["H3.16"]},{"c":"I3D17","t":"Height of rooms and other spaces","p":"Part I3 Farm buildings and farm sheds","u":"/editions/ncc-2025/adopted/volume-one/i-special-use-buildings/part-i3-farm-buildings-and-farm-sheds#I3D17","x":"F5D2 does not apply to a farm shed which has ceiling heights not less than—\nin a room, corridor, passageway or the like — 2.1 m; and\nin a room or space with a sloping ceiling or projections — a height of not less than 2.1 m for at least two-thirds of the floor area of the room or space, and when calculating the floor area of the room or space, any part that has a ceiling height of less than 1.5 m is not included; and\nin a stairway, ramp, landing or the like — 2.0 m measured vertically above the nosing line of stairway treads or the floor surface of the ramp, landing or the like.","g":"/ncc/i3d17","a19":["H3.17"]},{"c":"I3D18","t":"Artificial lighting","p":"Part I3 Farm buildings and farm sheds","u":"/editions/ncc-2025/adopted/volume-one/i-special-use-buildings/part-i3-farm-buildings-and-farm-sheds#I3D18","x":"(1) An artificial lighting system need not be provided in a farm building where—\noccupants are provided with visibility sufficient for safe movement through suitable alternative means; and\nthe use of artificial lighting could adversely affect the function of the building including, but not limited to—\nthe behaviour or welfare of animals being kept in the building; or\nthe cultivating or propagating of plants or fungi.\n(2) An artificial lighting system need not be provided in a farm shed.","g":"/ncc/i3d18","a19":["H3.18"]},{"c":"S33C1","t":"Scope","p":"Specification 33 Additional requirements","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/33-additional-requirements#S33C1","x":"This Specification contains requirements that must be complied with in addition to the modelling requirements of J1V1, J1V2 and J1V3.","g":"/ncc/s33c1","a19":["Spec JVa: 1"]},{"c":"S33C2","t":"Additional requirements — general","p":"Specification 33 Additional requirements","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/33-additional-requirements#S33C2","x":"(1) In addition to the modelling requirements for J1V1, J1V2, and J1V3, a building must comply with—\nfor general thermal construction, J4D3; and\nfor floor edge insulation, J4D7(3) and J4D7(4); and\nfor building sealing, J1V4 or J5; and\nfor deactivation, control and insulation of air-conditioning and mechanical ventilation systems—\nJ6D3(1)(a); and\nJ6D3(1)(b); and\nJ6D3(1)(c)(i)\nJ6D3(1)(e); and\nJ6D3(2); and\nJ6D3(3); and\nJ6D3(4)\nJ6D3(5)\nJ6D4(3); and\nJ6D4(4); and\nJ6D4(5)\nJ6D4(6)\nJ6D4(7)\nJ6D5; and\nJ6D6; and\nJ6D9; and\nfor testing water-to-air package air-conditioning equipment not less than 65 kW, AS/NZS ISO 13256.1 at test condition C3; and\nfor testing a refrigeration chiller, AHRI 551/591; and\nfor interior artificial lighting and power control, J7D4; and\nfor interior decorative and display lighting, J7D5; and\nfor artificial lighting around the exterior of a building, J7D6; and\nfor boiling water and chilled water storage units, J7D7; and\nfor deactivation of swimming pool heating and pumping, J8D4(2)(b) and J8D4(3); and\nfor deactivation of spa pool heating and pumping, J8D5(2)(b) and J8D5(3); and\nfor facilities for energy monitoring, Part J9; and\nfor deactivation of fixed outdoor space heating appliances, clause J6D10(3).\nfor facilitating the future replacement of gas-powered appliances with electrically-powered appliances—\nJ6D10 (5), (6) and (7); and\nJ8D3(3) and (4); and\nJ8D4 (6) and (7); and\nJ8D5(6) and (7).\n(2) In addition to the requirements of (1), a building using J1V1 must comply with J9D5(2) to (4) for facilities for solar photovoltaic panels.","g":"/ncc/s33c2","a19":["Spec JVa: 2"]},{"c":"S33C3","t":"Additional requirements — Green Star","p":"Specification 33 Additional requirements","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/33-additional-requirements#S33C3","x":"Where not included in the building energy simulation to satisfy J1V2(1), compliance must be achieved with—\nfor heating, cooling and ventilation equipment outside the scope of the Green Star model, Part J6; and\nfor artificial lighting outside the scope of the Green Star model, Part J7.","g":"/ncc/s33c3","a19":["Spec JVa: 4"]},{"c":"S34C1","t":"Scope","p":"Specification 34 Modelling parameters for J1V3","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/34-modelling-parameters-j1v3#S34C1","x":"This Specification contains the required modelling parameters for J1V3.","g":"/ncc/s34c1","a19":["Spec JVb: 1"]},{"c":"S34C2","t":"Reference building","p":"Specification 34 Modelling parameters for J1V3","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/34-modelling-parameters-j1v3#S34C2","x":"The annual greenhouse gas emissions must be calculated for the reference building in accordance with the following:\nThe reference building must—\nsubject to (b), (c) and (d), comply with Deemed-to-Satisfy Provisions in Parts J4 to J8; and\nhave the minimum amount of mechanical ventilation required by Part F6; and\nbe provided with a solar photovoltaic system that complies with—\nJ9D5(2)(a), J9D5(3) and J9D5(4) with PV panels modelled as parallel to the roof and assuming an average solar photovoltaic panel power rating of 225 W/m2; or\nJ9D5(2)(b), J9D5(3) and J9D5(4).\nThe external walls must have a solar absorptance of 0.6.\nThe U-Value of the wall-glazing construction must be calculated according to S37C3.\nThe solar admittance of the wall-glazing construction must be calculated according to S37C5.\nWhere J1V3(1)(b)(i) or J1V3(1)(b)(ii) applies, the air-conditioning must—\nfor 95% of the annual hours of operation, achieve dry bulb temperatures between—\n18°C to 25°C for conditioned spaces with transitory occupancy; and\nsubject to (ii), 21°C to 24°C in all other conditioned spaces; and\nif the proposed building has no mechanically provided cooling or has mixed mode cooling, have the same method of control and control set points for non-mechanical cooling as the proposed building.\nThe infiltration rate in each zone must be—\n0.7 air changes per hour throughout all zones when there is no mechanically supplied outdoor air; and\n0.35 air changes per hour throughout all zones at all other times.\nThe artificial lighting must achieve the required maximum illumination power density in Part J7 without applying the control device adjustment factors.\nMinimum Energy Performance Standards must be applied to services not covered by Parts J6 to J8.","g":"/ncc/s34c2","a19":["Spec JVb: 2"]},{"c":"Table S34C3","t":"Greenhouse gas emissions factors (kgCO2-e/GJ)","p":"Specification 34 Modelling parameters for J1V3","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/34-modelling-parameters-j1v3#_ec4006ea-721c-467f-917f-a7ace2f658e1","x":"Energy Source | ACT | NSW | NT | QLD | SA | TAS | VIC | WA\nElectricity | - | 51 | 110 | 120 | 22.5 | 9 | 135 | 83\nGas | - | 51.53 | 51.53 | 51.53 | 51.53 | 51.53 | 51.53 | 51.53\nTable Notes\nNational emissions factors are not applicable to calculations for buildings in the ACT as they do not take into account investments in renewable electricity generation in the national electricity market made by the ACT.\nValues for the ACT can be found in the ACT Appendix.","tb":"S34C3","g":"/ncc/table-s34c3"},{"c":"S34C3","t":"Proposed building and reference building","p":"Specification 34 Modelling parameters for J1V3","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/34-modelling-parameters-j1v3#S34C3","x":"(1) The annual greenhouse gas emissions must be calculated for the proposed building and the reference building using the same—\nannual greenhouse gas emissions calculation method; and\ngreenhouse gas emissions factors in accordance with (2); and\nlocation in accordance with (3); and\nclimatic data, using a projection at year 2050 made under a Representative Concentration Pathway with an 8.5 W/m² increase in radiative forcing; and\nadjacent structures and features; and\norientation; and\nbuilding form in accordance with (4); and\ntesting standards including for insulation, glazing, water heater and unitary air-conditioning equipment; and\nfabric and glazing in accordance with (5); and\nservices in accordance with (6) and S34C4; and\ntarget for thermal comfort minimums as per J1V3(1)(b).\n(2) For the purposes of (1)(b), greenhouse gas emissions factors must be based on the factors in Table S34C3.\n(3) For the purposes of (1)(c), location must be either—\nthe location where the building is to be constructed if appropriate climatic data is available; or\nthe nearest location with similar climatic conditions, for which climatic data is available.\n(4) For the purposes of (1)(g), building form must include the same—\nroof geometry; and\nfloor plan; and\nnumber of storeys; and\nlocation, extent and configuration of ground floors and basements; and\nsize and location of glazing; and\nexternal doors.\n(5) For the purposes of (1)(i), fabric and glazing must include the same—\nthermal resistance of air films including any adjustment factors, moisture content of materials and the like; and\ndimensions of external, internal and separating walls; and\ninternal shading devices, including their colour and their criteria for operation; and\nlocation and extent of thermal mass.\n(6) For the purposes of (1)(j), services must include the same—\nrange and type of services and energy sources including the same proportions and functions of air-cooled and water-cooled air-conditioning equipment; and\nair-conditioning zones including—\nseparate zones for each storey; and\nseparate zones for each sole-occupancy unit; and\nin spaces larger than 20 m², separate perimeter zones, no deeper than 4 m adjacent to external walls with windows facing—\nwithin 45° of true north; and\nwithin 45° of true south; and\nwithin 45° of true east; and\nwithin 45° of true west; and\nseparate centre zones comprising the remainder of each sole-occupancy unit within each storey; and\nthe same method of calculating the temperature difference across air-conditioning zone boundaries; and\nthe same method of combining zones with similar heating and cooling requirements, where necessary to simplify the simulation; and\nfloor coverings and furniture and fittings density; and\ninternal artificial lighting illumination levels; and\ninternal heat gains including people, lighting, appliances, meals and other electric power loads; and\nair-conditioning, including chiller, fan and boiler equipment, system configuration; and\nprofiles for occupancy, air-conditioning, lighting and internal heat gains from people, hot meals, appliances, equipment and heated water supply systems based on—\nSpecification 35; or\nNABERS Energy simulation requirements; or\nGreen Star simulation requirements; or\nthe actual building if—\nthe operating hours per year are not less than 2,500; or\nthe daily operating profiles are not listed in Specification 35; and\nsupply heated water temperature and rate of use; and\ninfiltration values, subject to (7); and\nsequencing for water heaters, refrigeration chillers and heat rejection equipment such as cooling towers; and\nwhere J1V3(1)(b)(i) applies, representation of clothing and metabolic rate of the occupants, and air speed from mechanical services; and\ncontrol of air-conditioning, in accordance with the requirements of Part J6, except if the controls for the proposed building are not adequately specified or cannot be simulated, the sample control specifications in Appendix B of AIRAH-DA28 must be used; and\nenvironmental conditions such as ground reflectivity, form factors for topography and built environment, temperature of external bounding surfaces, air velocities across external surfaces, vegetation and the like; and\nnumber, sizes, floors and traffic served by lifts and escalators; and\nloss factors for solar PV installation.\n(7) For the purposes of (6)(i), the intended building leakage at 50 Pa may be converted into a whole building infiltration value for the proposed building infiltration using Tables 4.16 to 4.24 of CIBSE Guide A if all of the following have been specified:\nAdditional sealing provisions to those required by Part J5.\nAn intended building leakage of less than 10 m3/hr.m2 at 50 Pa.\nPressure testing to verify achievement of the intended building leakage.\n(8) Where J1V3(1)(b)(iii), (iv) or (v) applies, the air-conditioning must—\nsubject to (b), for 95% of the annual hours of operation, achieve dry bulb temperatures between—\n18°C to 25°C for conditioned spaces with transitory occupancy; and\n21°C to 24°C in all other conditioned spaces; and\nif the proposed building has no mechanically provided cooling or has mixed mode cooling, the proposed building and reference building must have the same method of control and control set points for non-mechanical cooling.\nTable S34C3 Greenhouse gas emissions factors (kgCO2-e/GJ)\nEnergy Source\nACT\nNSW\nNT\nQLD\nSA\nTAS\nVIC\nWA\nElectricity\n-\n51\n110\n120\n22.5\n9\n135\n83\nGas\n-\n51.53\n51.53\n51.53\n51.53\n51.53\n51.53\n51.53\nTable Notes\nNational emissions factors are not applicable to calculations for buildings in the ACT as they do not take into account investments in renewable electricity generation in the national electricity market made by the ACT.\nValues for the ACT can be found in the ACT Appendix.","g":"/ncc/s34c3","a19":["Spec JVb: 3"]},{"c":"S34C4","t":"Services — proposed and reference building","p":"Specification 34 Modelling parameters for J1V3","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/34-modelling-parameters-j1v3#S34C4","x":"For the modelling of services for the purposes of calculating annual greenhouse gas emissions —\nsystem demand and response for all items of plant must be calculated on a not less frequent than hourly basis; and\nenergy usage of all items of plant must be calculated with allowances for—\npart load performance; and\nstaging to meet system demand; and\nenergy usage of cooling plant must be calculated with allowances for—\nthe impact of chilled water temperature on chiller efficiency; and\nthe impact of condenser water temperature on water-cooled plant efficiency; and\nthe impact of ambient temperature on air-cooled plant efficiency; and\nthe energy use of primary pumps serving individual chillers; and\nthe energy use of auxiliary equipment, including controls and oil heating for chillers; and\nthermal losses in the chilled water system; and\nthe impact of chilled water temperature on thermal losses in the chilled water system; and\nenergy usage of water heating systems for space heating must be calculated with allowances for—\nthe impact of water temperature on water heater efficiency; and\nthe energy use of primary or feedwater pumps serving individual water heaters; and\nthermal losses in water heating systems; and\nthe thermal mass of water heating systems, accounting for thermal losses during periods when the system is not operating; and\nenergy usage of fan and pump systems must be calculated with allowances for—\nthe method of capacity regulation; and\nthe use of either fixed or variable pressure control; and\nenergy usage of pump systems must be calculated with allowances for the system fixed static pressure head; and\nenergy usage of auxiliary equipment associated with co-generation and tri-generation systems, including pumps, cooling towers and jacket heaters, must be calculated; and\nif energy usage for each is the same in the proposed building and the reference building, omission from the calculation for both the proposed building and reference building may be made for—\nheated water supply for food preparation and sanitary purposes; and\nlifts; and\nescalators; and\nelectric vehicle charging; and\nenergy use of a lift in a building with more than one classification may be apportioned according to the number of storeys of the part for which the annual greenhouse gas emissions are being calculated.","g":"/ncc/s34c4","a19":["Spec JVb: 4"]},{"c":"S35C1","t":"Scope","p":"Specification 35 Modelling profiles for J1V3","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/35-modelling-profiles-j1v3#S35C1","x":"This Specification contains modelling profiles as referenced in S34C3(6)(g).","g":"/ncc/s35c1","a19":["Spec JVc: 1"]},{"c":"Table * * * * * ","t":"This table reference has been deliberately left blank","p":"Specification 35 Modelling profiles for J1V3","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/35-modelling-profiles-j1v3#_c6ebf231-aa8d-413e-a15a-fdeb10c394ff","x":"","tb":"S35C2","g":"/ncc/table"},{"c":"Table S35C2b","t":"Occupancy and operation profiles of a Class 3 hotel","p":"Specification 35 Modelling profiles for J1V3","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/35-modelling-profiles-j1v3#_7ee35644-909b-4fd7-a34c-62f32dfc666d","x":"Time period (local standard time) | Occupancy (Daily) | Artificial lighting (Daily) | Appliances and equipment (Daily) | Air-conditioning (Daily)\n12:00am to 1:00am | 90% | 5% | 20% | On\n1:00am to 2:00am | 90% | 5% | 20% | On\n2:00am to 3:00am | 90% | 5% | 15% | On\n3:00am to 4:00am | 90% | 5% | 15% | On\n4:00am to 5:00am | 90% | 5% | 15% | On\n5:00am to 6:00am | 80% | 25% | 15% | On\n6:00am to 7:00am | 70% | 80% | 40% | On\n7:00am to 8:00am | 60% | 80% | 80% | On\n8:00am to 9:00am | 60% | 50% | 50% | On\n9:00am to 10:00am | 30% | 20% | 30% | On\n10:00am to 11:00am | 10% | 20% | 20% | Off\n11:00am to 12:00pm | 10% | 20% | 20% | Off\n12:00pm to 1:00pm | 10% | 20% | 20% | Off\n1:00pm to 2:00pm | 10% | 20% | 20% | Off\n2:00pm to 3:00pm | 10% | 20% | 20% | Off\n3:00pm to 4:00pm | 10% | 20% | 20% | Off\n4:00pm to 5:00pm | 20% | 20% | 20% | On\n5:00pm to 6:00pm | 30% | 50% | 40% | On\n6:00pm to 7:00pm | 40% | 50% | 40% | On\n7:00pm to 8:00pm | 50% | 50% | 50% | On\n8:00pm to 9:00pm | 60% | 50% | 60% | On\n9:00pm to 10:00pm | 70% | 50% | 60% | On\n10:00pm to 11:00pm | 70% | 50% | 40% | On\n11:00pm to 12:00am | 90% | 50% | 20% | On\nTable Notes\nThe occupancy profile is expressed as a percentage of the maximum number of people that can be accommodated in the Class 3 building.\nThe artificial lighting profile is expressed as a percentage of the maximum illumination power density permitted under Part J7.\nThe air-conditioning profile is expressed as the plant status.","tb":"S35C2","g":"/ncc/table-s35c2b"},{"c":"Table S35C2c","t":"Weekday occupancy and operation profiles of a Class 5 building, a Class 7 warehouse, a Class 8 Laboratory or a Class 9a clinic, day surgery or procedure unit","p":"Specification 35 Modelling profiles for J1V3","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/35-modelling-profiles-j1v3#_6cdb33f3-7b1f-4b51-9791-4739e4392562","x":"Time period (local standard time) | Occupancy (Monday to Friday) | Artificial lighting (Monday to Friday) | Appliances and equipment (Monday to Friday) | Air-conditioning (Monday to Friday)\n12:00am to 1:00am | 0% | 0% | 25% | Off\n1:00am to 2:00am | 0% | 0% | 25% | Off\n2:00am to 3:00am | 0% | 0% | 25% | Off\n3:00am to 4:00am | 0% | 0% | 25% | Off\n4:00am to 5:00am | 0% | 0% | 25% | Off\n5:00am to 6:00am | 0% | 0% | 25% | Off\n6:00am to 7:00am | 0% | 0% | 25% | Off\n7:00am to 8:00am | 10% | 40% | 65% | On\n8:00am to 9:00am | 20% | 90% | 80% | On\n9:00am to 10:00am | 70% | 100% | 100% | On\n10:00am to 11:00am | 70% | 100% | 100% | On\n11:00am to 12:00pm | 70% | 100% | 100% | On\n12:00pm to 1:00pm | 70% | 100% | 100% | On\n1:00pm to 2:00pm | 70% | 100% | 100% | On\n2:00pm to 3:00pm | 70% | 100% | 100% | On\n3:00pm to 4:00pm | 70% | 100% | 100% | On\n4:00pm to 5:00pm | 70% | 100% | 100% | On\n5:00pm to 6:00pm | 35% | 80% | 80% | On\n6:00pm to 7:00pm | 10% | 60% | 65% | Off\n7:00pm to 8:00pm | 5% | 60% | 55% | Off\n8:00pm to 9:00pm | 5% | 50% | 25% | Off\n9:00pm to 10:00pm | 0% | 0% | 25% | Off\n10:00pm to 11:00pm | 0% | 0% | 25% | Off\n11:00pm to 12:00am | 0% | 0% | 25% | Off\nTable Notes\nThe occupancy profile is expressed as a percentage of the maximum number of people that can be accommodated in the building.\nThe artificial lighting profile is expressed as a percentage of the maximum illumination power density permitted under Part J7.\nThe appliances and equipment profile is expressed as a percentage of the maximum internal heat gain in Table S35C2l.\nThe air-conditioning profile is expressed as the plant status.","tb":"S35C2","g":"/ncc/table-s35c2c"},{"c":"Table S35C2d","t":"Weekend occupancy and operation profiles of a Class 5 building, a Class 7 warehouse, a Class 8 Laboratory or a Class 9a clinic, day surgery or procedure unit","p":"Specification 35 Modelling profiles for J1V3","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/35-modelling-profiles-j1v3#_82b1bce5-e8a9-4d8d-9989-dc5e09179061","x":"Time period (local standard time) | Occupancy (Saturday, Sunday and holidays) | Artificial lighting (Saturday, Sunday and holidays) | Appliances and equipment (Saturday, Sunday and holidays) | Air-conditioning (Saturday, Sunday and holidays)\n12:00am to 1:00am | 0% | 0% | 25% | Off\n1:00am to 2:00am | 0% | 0% | 25% | Off\n2:00am to 3:00am | 0% | 0% | 25% | Off\n3:00am to 4:00am | 0% | 0% | 25% | Off\n4:00am to 5:00am | 0% | 0% | 25% | Off\n5:00am to 6:00am | 0% | 0% | 25% | Off\n6:00am to 7:00am | 0% | 0% | 25% | Off\n7:00am to 8:00am | 0% | 0% | 25% | Off\n8:00am to 9:00am | 5% | 15% | 25% | Off\n9:00am to 10:00am | 5% | 15% | 25% | Off\n10:00am to 11:00am | 5% | 15% | 25% | Off\n11:00am to 12:00pm | 5% | 15% | 25% | Off\n12:00pm to 1:00pm | 5% | 15% | 25% | Off\n1:00pm to 2:00pm | 5% | 15% | 25% | Off\n2:00pm to 3:00pm | 5% | 15% | 25% | Off\n3:00pm to 4:00pm | 5% | 15% | 25% | Off\n4:00pm to 5:00pm | 5% | 15% | 25% | Off\n5:00pm to 6:00pm | 0% | 0% | 25% | Off\n6:00pm to 7:00pm | 0% | 0% | 25% | Off\n7:00pm to 8:00pm | 0% | 0% | 25% | Off\n8:00pm to 9:00pm | 0% | 0% | 25% | Off\n9:00pm to 10:00pm | 0% | 0% | 25% | Off\n10:00pm to 11:00pm | 0% | 0% | 25% | Off\n11:00pm to 12:00am | 0% | 0% | 25% | Off\nTable Notes\nThe occupancy profile is expressed as a percentage of the maximum number of people that can be accommodated in the building.\nThe artificial lighting profile is expressed as a percentage of the maximum illumination power density permitted under Part J7.\nThe appliances and equipment profile is expressed as a percentage of the maximum internal heat gain in Table S35C2l.\nThe air-conditioning profile is expressed as the plant status.","tb":"S35C2","g":"/ncc/table-s35c2d"},{"c":"Table S35C2e","t":"Occupancy and operation profiles of a Class 6 shop or shopping centre","p":"Specification 35 Modelling profiles for J1V3","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/35-modelling-profiles-j1v3#_d51fb770-84da-40fa-bb93-b08e4fc7a464","x":"Time period (local standard time) | Occupancy (Daily) | Artificial lighting (Daily) | Appliances and equipment (Daily) | Air-conditioning (Daily)\n12:00am to 1:00am | 0% | 0% | 25% | Off\n1:00am to 2:00am | 0% | 0% | 25% | Off\n2:00am to 3:00am | 0% | 0% | 25% | Off\n3:00am to 4:00am | 0% | 0% | 25% | Off\n4:00am to 5:00am | 0% | 0% | 25% | Off\n5:00am to 6:00am | 0% | 0% | 25% | Off\n6:00am to 7:00am | 0% | 0% | 25% | Off\n7:00am to 8:00am | 10% | 100% | 70% | On\n8:00am to 9:00am | 20% | 100% | 70% | On\n9:00am to 10:00am | 20% | 100% | 70% | On\n10:00am to 11:00am | 15% | 100% | 70% | On\n11:00am to 12:00pm | 25% | 100% | 70% | On\n12:00pm to 1:00pm | 25% | 100% | 70% | On\n1:00pm to 2:00pm | 20% | 100% | 70% | On\n2:00pm to 3:00pm | 20% | 100% | 70% | On\n3:00pm to 4:00pm | 20% | 100% | 70% | On\n4:00pm to 5:00pm | 20% | 100% | 70% | On\n5:00pm to 6:00pm | 5% | 100% | 70% | On\n6:00pm to 7:00pm | 5% | 100% | 70% | Off\n7:00pm to 8:00pm | 0% | 0% | 10% | Off\n8:00pm to 9:00pm | 0% | 0% | 10% | Off\n9:00pm to 10:00pm | 0% | 0% | 10% | Off\n10:00pm to 11:00pm | 0% | 0% | 10% | Off\n11:00pm to 12:00am | 0% | 0% | 10% | Off\nTable Notes\nThe occupancy profile is expressed as a percentage of the maximum number of people that can be accommodated in the building.\nThe artificial lighting profile is expressed as a percentage of the maximum illumination power density permitted under Part J7.\nThe appliances and equipment profile is expressed as a percentage of the maximum internal heat gain in S35C2l.\nThe air-conditioning profile is expressed as the plant status.","tb":"S35C2","g":"/ncc/table-s35c2e"},{"c":"Table S35C2f","t":"Occupancy and operation profiles of a Class 6 restaurant or cafe","p":"Specification 35 Modelling profiles for J1V3","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/35-modelling-profiles-j1v3#_d8e14281-fd9b-4d91-94b4-5c974f26612d","x":"Time period (local standard time) | Occupancy (Monday to Saturday) | Artificial lighting (Monday to Saturday) | Appliances and equipment (Monday to Saturday) | Air-conditioning (Monday to Saturday)\n12:00am to 1:00am | 0% | 5% | 15% | Off\n1:00am to 2:00am | 0% | 5% | 15% | Off\n2:00am to 3:00am | 0% | 5% | 15% | Off\n3:00am to 4:00am | 0% | 5% | 15% | Off\n4:00am to 5:00am | 0% | 5% | 15% | Off\n5:00am to 6:00am | 0% | 5% | 15% | Off\n6:00am to 7:00am | 5% | 40% | 40% | Off\n7:00am to 8:00am | 5% | 40% | 40% | On\n8:00am to 9:00am | 5% | 60% | 60% | On\n9:00am to 10:00am | 5% | 60% | 60% | On\n10:00am to 11:00am | 20% | 90% | 90% | On\n11:00am to 12:00pm | 50% | 90% | 90% | On\n12:00pm to 1:00pm | 80% | 90% | 90% | On\n1:00pm to 2:00pm | 70% | 90% | 90% | On\n2:00pm to 3:00pm | 40% | 90% | 90% | On\n3:00pm to 4:00pm | 20% | 90% | 90% | On\n4:00pm to 5:00pm | 25% | 90% | 90% | On\n5:00pm to 6:00pm | 50% | 90% | 90% | On\n6:00pm to 7:00pm | 80% | 90% | 90% | On\n7:00pm to 8:00pm | 80% | 90% | 90% | On\n8:00pm to 9:00pm | 80% | 90% | 90% | On\n9:00pm to 10:00pm | 50% | 90% | 90% | On\n10:00pm to 11:00pm | 35% | 50% | 50% | On\n11:00pm to 12:00am | 20% | 30% | 30% | On\nTable Notes\nThe occupancy profile is expressed as a percentage of the maximum number of people that can be accommodated in the building.\nThe artificial lighting profile is expressed as a percentage of the maximum illumination power density permitted under Part J7.\nThe appliances and equipment profile is expressed as a percentage of the maximum internal heat gain in S35C2l.\nThe air-conditioning profile is expressed as the plant status.\nSunday profile is 5% continuous artificial lighting and 5% continuous appliances and equipment where there is no occupancy and the air-conditioning is “off”.","tb":"S35C2","g":"/ncc/table-s35c2f"},{"c":"Table S35C2g","t":"Occupancy and operation profiles of a Class 9a ward area","p":"Specification 35 Modelling profiles for J1V3","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/35-modelling-profiles-j1v3#_b99593e5-fc68-426f-807d-594100be985f","x":"Time period (local standard time) | Occupancy (Daily) | Artificial lighting (Daily) | Air-conditioning (Daily)\n12:00am to 1:00am | 70% | 5% | On\n1:00am to 2:00am | 70% | 5% | On\n2:00am to 3:00am | 70% | 5% | On\n3:00am to 4:00am | 70% | 5% | On\n4:00am to 5:00am | 70% | 5% | On\n5:00am to 6:00am | 70% | 25% | On\n6:00am to 7:00am | 70% | 80% | On\n7:00am to 8:00am | 70% | 80% | On\n8:00am to 9:00am | 70% | 50% | On\n9:00am to 10:00am | 70% | 20% | On\n10:00am to 11:00am | 70% | 20% | On\n11:00am to 12:00pm | 70% | 20% | On\n12:00pm to 1:00pm | 70% | 20% | On\n1:00pm to 2:00pm | 70% | 20% | On\n2:00pm to 3:00pm | 70% | 20% | On\n3:00pm to 4:00pm | 70% | 20% | On\n4:00pm to 5:00pm | 70% | 20% | On\n5:00pm to 6:00pm | 70% | 50% | On\n6:00pm to 7:00pm | 70% | 50% | On\n7:00pm to 8:00pm | 70% | 50% | On\n8:00pm to 9:00pm | 70% | 50% | On\n9:00pm to 10:00pm | 70% | 50% | On\n10:00pm to 11:00pm | 70% | 50% | On\n11:00pm to 12:00am | 70% | 5% | On\nTable Notes\nThe occupancy profile is expressed as a percentage of the maximum number of people that can be accommodated in the building.\nThe artificial lighting profile is expressed as a percentage of the maximum illumination power density permitted under Part J7.\nThe air-conditioning profile is expressed as the plant status.","tb":"S35C2","g":"/ncc/table-s35c2g"},{"c":"Table S35C2h","t":"Occupancy and operation profiles of a Class 9b theatre or cinema","p":"Specification 35 Modelling profiles for J1V3","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/35-modelling-profiles-j1v3#_6ecc85f0-19de-408a-830c-abe2db9b15e9","x":"Time period (local standard time) | Occupancy (Monday to Friday) | Occupancy (Saturday and Sunday) | Artificial lighting (Monday to Friday) | Artificial lighting (Saturday and Sunday) | Air-conditioning (Monday to Friday) | Air-conditioning (Saturday and Sunday)\n12:00am to 1:00am | 0% | 0% | 5% | 5% | Off | Off\n1:00am to 2:00am | 0% | 0% | 5% | 5% | Off | Off\n2:00am to 3:00am | 0% | 0% | 5% | 5% | Off | Off\n3:00am to 4:00am | 0% | 0% | 5% | 5% | Off | Off\n4:00am to 5:00am | 0% | 0% | 5% | 5% | Off | Off\n5:00am to 6:00am | 0% | 0% | 5% | 5% | Off | Off\n6:00am to 7:00am | 0% | 0% | 5% | 5% | Off | Off\n7:00am to 8:00am | 0% | 0% | 5% | 5% | Off | On\n8:00am to 9:00am | 0% | 20% | 100% | 100% | Off | On\n9:00am to 10:00am | 0% | 70% | 10% | 10% | Off | On\n10:00am to 11:00am | 0% | 70% | 10% | 10% | Off | On\n11:00am to 12:00pm | 0% | 70% | 10% | 10% | On | On\n12:00pm to 1:00pm | 20% | 20% | 100% | 100% | On | On\n1:00pm to 2:00pm | 70% | 70% | 5% | 5% | On | On\n2:00pm to 3:00pm | 70% | 70% | 5% | 5% | On | On\n3:00pm to 4:00pm | 70% | 70% | 5% | 5% | On | On\n4:00pm to 5:00pm | 70% | 70% | 5% | 5% | On | On\n5:00pm to 6:00pm | 20% | 20% | 100% | 100% | On | On\n6:00pm to 7:00pm | 20% | 20% | 100% | 100% | On | On\n7:00pm to 8:00pm | 70% | 70% | 100% | 100% | On | On\n8:00pm to 9:00pm | 70% | 70% | 5% | 5% | On | On\n9:00pm to 10:00pm | 70% | 70% | 5% | 5% | On | On\n10:00pm to 11:00pm | 70% | 70% | 5% | 5% | On | On\n11:00pm to 12:00am | 10% | 10% | 100% | 100% | On | On\nTable Notes\nThe occupancy profile is expressed as a percentage of the maximum number of people that can be accommodated in the building.\nThe artificial lighting profile is expressed as a percentage of the maximum illumination power density permitted under Part J7.\nThe air-conditioning profile is expressed as the plant status.","tb":"S35C2","g":"/ncc/table-s35c2h"},{"c":"Table S35C2i","t":"Occupancy and operation profiles of a Class 9b conference facility","p":"Specification 35 Modelling profiles for J1V3","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/35-modelling-profiles-j1v3#_9d449705-1791-444b-a2b4-bfc9ef485e67","x":"Hour | Occupancy (Daily) | Artificial lighting and equipment (Daily) | Air-conditioning (Daily)\n12:00am to 1:00am | 0% | 15% | Off\n1:00am to 2:00am | 0% | 15% | Off\n2:00am to 3:00am | 0% | 15% | Off\n3:00am to 4:00am | 0% | 15% | Off\n4:00am to 5:00am | 0% | 15% | Off\n5:00am to 6:00am | 0% | 15% | Off\n6:00am to 7:00am | 5% | 25% | On\n7:00am to 8:00am | 10% | 45% | On\n8:00am to 9:00am | 20% | 45% | On\n9:00am to 10:00am | 20% | 45% | On\n10:00am to 11:00am | 25% | 60% | On\n11:00am to 12:00pm | 30% | 60% | On\n12:00pm to 1:00pm | 30% | 60% | On\n1:00pm to 2:00pm | 35% | 60% | On\n2:00pm to 3:00pm | 30% | 45% | On\n3:00pm to 4:00pm | 30% | 60% | On\n4:00pm to 5:00pm | 35% | 60% | On\n5:00pm to 6:00pm | 25% | 60% | On\n6:00pm to 7:00pm | 20% | 60% | On\n7:00pm to 8:00pm | 15% | 25% | On\n8:00pm to 9:00pm | 10% | 25% | On\n9:00pm to 10:00pm | 10% | 25% | On\n10:00pm to 11:00pm | 10% | 25% | On\n11:00pm to 12:00am | 5% | 25% | Off\nTable Notes\nThe occupancy profile is expressed as a percentage of the maximum number of people that can be accommodated in the building.\nThe artificial lighting profile is expressed as a percentage of the maximum illumination power density permitted under Part J7.\nThe appliances and equipment profile is expressed as a percentage of the maximum internal heat gain in S35C2l.\nThe air-conditioning profile is expressed as the plant status.","tb":"S35C2","g":"/ncc/table-s35c2i"},{"c":"Table S35C2j","t":"Occupancy and operation profiles of a Class 9b school","p":"Specification 35 Modelling profiles for J1V3","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/35-modelling-profiles-j1v3#_d40c07f0-9acb-42cb-ace2-7ebda767de38","x":"Time period (local standard time) | Occupancy (Monday to Friday) | Artificial lighting (Monday to Friday) | Appliances and equipment (Monday to Friday) | Air-conditioning (Monday to Friday)\n12:00am to 1:00am | 0% | 0% | 5% | Off\n1:00am to 2:00am | 0% | 0% | 5% | Off\n2:00am to 3:00am | 0% | 0% | 5% | Off\n3:00am to 4:00am | 0% | 0% | 5% | Off\n4:00am to 5:00am | 0% | 0% | 5% | Off\n5:00am to 6:00am | 0% | 0% | 5% | Off\n6:00am to 7:00am | 0% | 0% | 5% | Off\n7:00am to 8:00am | 5% | 20% | 30% | On\n8:00am to 9:00am | 75% | 85% | 85% | On\n9:00am to 10:00am | 90% | 95% | 95% | On\n10:00am to 11:00am | 90% | 95% | 95% | On\n11:00am to 12:00pm | 90% | 95% | 95% | On\n12:00pm to 1:00pm | 50% | 60% | 70% | On\n1:00pm to 2:00pm | 50% | 60% | 70% | On\n2:00pm to 3:00pm | 90% | 95% | 95% | On\n3:00pm to 4:00pm | 70% | 90% | 80% | On\n4:00pm to 5:00pm | 50% | 70% | 60% | On\n5:00pm to 6:00pm | 20% | 20% | 20% | Off\n6:00pm to 7:00pm | 20% | 20% | 20% | Off\n7:00pm to 8:00pm | 20% | 20% | 20% | Off\n8:00pm to 9:00pm | 10% | 5% | 10% | Off\n9:00pm to 10:00pm | 5% | 0% | 5% | Off\n10:00pm to 11:00pm | 5% | 0% | 5% | Off\n11:00pm to 12:00am | 5% | 0% | 5% | Off\nTable Notes\nThe occupancy profile is expressed as a percentage of the maximum number of people that can be accommodated in the building.\nThe artificial lighting profile is expressed as a percentage of the maximum illumination power density permitted under Part J7.\nThe appliances and equipment profile is expressed as a percentage of the maximum internal heat gain in S35C2l.\nThe air-conditioning profile is expressed as the plant status.\nSaturday and Sunday profiles are 5% continuous artificial lighting and 5% continuous appliances and equipment, where there is no occupancy and the air-conditioning is “off”.","tb":"S35C2","g":"/ncc/table-s35c2j"},{"c":"Table S35C2k","t":"Occupancy and operation profiles of a Class 9c aged care facility","p":"Specification 35 Modelling profiles for J1V3","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/35-modelling-profiles-j1v3#_3475a9a2-45c7-4bb3-8066-1f956ab26747","x":"Time period (local standard time) | Occupancy (Monday to Friday) | Occupancy (Saturday, Sunday and holidays) | Artificial lighting (Daily) | Air-conditioning (Monday to Friday) | Air-conditioning (Saturday, Sunday and holidays)\n12:00am to 1:00am | 85% | 85% | 5% | On | On\n1:00am to 2:00am | 85% | 85% | 5% | On | On\n2:00am to 3:00am | 85% | 85% | 5% | On | On\n3:00am to 4:00am | 85% | 85% | 5% | On | On\n4:00am to 5:00am | 85% | 85% | 5% | On | On\n5:00am to 6:00am | 85% | 85% | 25% | On | On\n6:00am to 7:00am | 85% | 85% | 80% | On | On\n7:00am to 8:00am | 80% | 85% | 80% | On | On\n8:00am to 9:00am | 50% | 50% | 50% | On | On\n9:00am to 10:00am | 50% | 50% | 20% | Off | On\n10:00am to 11:00am | 50% | 50% | 20% | Off | On\n11:00am to 12:00pm | 50% | 50% | 20% | Off | On\n12:00pm to 1:00pm | 50%5 | 50% | 20% | Off | On\n1:00pm to 2:00pm | 50% | 50% | 20% | Off | On\n2:00pm to 3:00pm | 50% | 50% | 20% | Off | On\n3:00pm to 4:00pm | 50% | 50% | 20% | Off | On\n4:00pm to 5:00pm | 50% | 50% | 20% | On | On\n5:00pm to 6:00pm | 50% | 50% | 50% | On | On\n6:00pm to 7:00pm | 70% | 50% | 50% | On | On\n7:00pm to 8:00pm | 70% | 70% | 50% | On | On\n8:00pm to 9:00pm | 80% | 80% | 50% | On | On\n9:00pm to 10:00pm | 85% | 80% | 50% | On | On\n10:00pm to 11:00pm | 85% | 85% | 50% | On | On\n11:00pm to 12:00am | 85% | 85% | 5% | On | On\nTable Notes\nThe occupancy profile is expressed as a percentage of the maximum number of people that can be accommodated in the Class 9c building.\nThe artificial lighting profile is expressed as a percentage of the maximum illumination power density permitted under Part J7.\nThe air-conditioning profile is expressed as the plant status.","tb":"S35C2","g":"/ncc/table-s35c2k"},{"c":"Table S35C2l","t":"Internal heat gains for appliances and equipment","p":"Specification 35 Modelling profiles for J1V3","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/35-modelling-profiles-j1v3#_7dad389f-a0e9-42bb-ad33-9ac62783bbda","x":"Application | Internal sensible heat gain rate\nClass 9a building ward area | 5 W/m2 averaged for 24 hours per day, 7 days per week, continuous operation\nClass 8 laboratory and a Class 9a clinic, day surgery and a procedure unit | 15 W/m2\nClass 6 shop and shopping centre, Class 6 cafe and restaurant and Class 9b school | 5 W/m2\nOther applications | No load\nClass 3 (sole-occupancy unit) | 160 W per room\nClass 3 dormitories | No load\nClass 5 building | 11 W/m2\nClass 9c building | 160 W per room\nClass 9b (conference facilities only) | 150 W per room plus 10 W per person","tb":"S35C2","g":"/ncc/table-s35c2l"},{"c":"Table S35C2m","t":"Heated water supply consumption rates","p":"Specification 35 Modelling profiles for J1V3","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/35-modelling-profiles-j1v3#_77c6fd1d-50e2-4f15-a97c-c7d460450591","x":"Application | Daily consumption rate at 60°C\nResidential part of a hotel or motel | 100 L/sole-occupancy unit\nDormitory, boarding house, guest house, hostel, lodging house and backpackers accommodation | 50 L/person\nResidential part of a school, accommodation for the aged, children or people with a disability and a detention centre or a health-care building which accommodates members of staff\nClass 9c building\nOffice, laboratory, shop and assembly building | 4 L/person\nDining room, restaurant and cafe | 9 L/meal\nHealth-care building, ward area | 70 L/patient\nSchool | 7 L/person\nOther applications | 4 L/person","tb":"S35C2","g":"/ncc/table-s35c2m"},{"c":"Table S35C2n","t":"Internal heat gains for occupants and hot meals","p":"Specification 35 Modelling profiles for J1V3","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/35-modelling-profiles-j1v3#_7d319f4b-75b5-4a1f-9f5d-f05d21195931","x":"Application | Internal heat gains per person\nDining room, restaurant or cafe | 80 W sensible heat gain and 80 W latent heat gain\nThe average adjusted metabolic rate for sedentary work from Table 45 of AIRAH-DA09\nThe heat emission rate for sedentary work from Table 6.3 of CIBSE Guide A\nOther applications | 75 W sensible heat gain and 55 W latent heat gain\nAn average adjusted metabolic rate from Table 45 of AIRAH-DA09\nA heat emission rate from Table 6.3 of CIBSE Guide A\nTable Notes\nThe number of people must be calculated in accordance with D2D18.\nFor a dining room, restaurant or cafe, the internal heat gains per person account for heat gains from both occupants and hot meals.\nFor other applications, the internal heat gains per person only account for heat gains from occupants.","tb":"S35C2","g":"/ncc/table-s35c2n"},{"c":"S35C2","t":"Modelling profiles","p":"Specification 35 Modelling profiles for J1V3","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/35-modelling-profiles-j1v3#S35C2","x":"(1) The air-conditioning, must be modelled on the basis of—\nthe daily occupancy and operation profiles in Tables S35C2b, S35C2c, S35C2d, S35C2e, S35C2f, S35C2g, S35C2h, S35C2i, S35C2j and S35C2k; and\nthe internal heat gains in a building—\nfrom occupants and hot meals, in accordance with one of the options in Table S35C2n; and\nfrom appliances and equipment, in accordance with Table S35C2l; and\nfrom artificial lighting, determined in accordance with (2).\n(2) The artificial lighting, must be modelled on the basis of the proposed level of artificial lighting in the building with the daily profile in Tables S35C2b, S35C2c, S35C2d, S35C2e, S35C2f, S35C2g, S35C2h, S35C2i, S35C2j and S35C2k.\n(3) The heated water supply, must be modelled on the basis of the consumption rates of Table S35C2m.\nTable * * * * * This table reference has been deliberately left blank\nTable S35C2b Occupancy and operation profiles of a Class 3 hotel\nTime period (local standard time)\nOccupancy (Daily)\nArtificial lighting (Daily)\nAppliances and equipment (Daily)\nAir-conditioning (Daily)\n12:00am to 1:00am\n90%\n5%\n20%\nOn\n1:00am to 2:00am\n90%\n5%\n20%\nOn\n2:00am to 3:00am\n90%\n5%\n15%\nOn\n3:00am to 4:00am\n90%\n5%\n15%\nOn\n4:00am to 5:00am\n90%\n5%\n15%\nOn\n5:00am to 6:00am\n80%\n25%\n15%\nOn\n6:00am to 7:00am\n70%\n80%\n40%\nOn\n7:00am to 8:00am\n60%\n80%\n80%\nOn\n8:00am to 9:00am\n60%\n50%\n50%\nOn\n9:00am to 10:00am\n30%\n20%\n30%\nOn\n10:00am to 11:00am\n10%\n20%\n20%\nOff\n11:00am to 12:00pm\n10%\n20%\n20%\nOff\n12:00pm to 1:00pm\n10%\n20%\n20%\nOff\n1:00pm to 2:00pm\n10%\n20%\n20%\nOff\n2:00pm to 3:00pm\n10%\n20%\n20%\nOff\n3:00pm to 4:00pm\n10%\n20%\n20%\nOff\n4:00pm to 5:00pm\n20%\n20%\n20%\nOn\n5:00pm to 6:00pm\n30%\n50%\n40%\nOn\n6:00pm to 7:00pm\n40%\n50%\n40%\nOn\n7:00pm to 8:00pm\n50%\n50%\n50%\nOn\n8:00pm to 9:00pm\n60%\n50%\n60%\nOn\n9:00pm to 10:00pm\n70%\n50%\n60%\nOn\n10:00pm to 11:00pm\n70%\n50%\n40%\nOn\n11:00pm to 12:00am\n90%\n50%\n20%\nOn\nTable Notes\nThe occupancy profile is expressed as a percentage of the maximum number of people that can be accommodated in the Class 3 building.\nThe artificial lighting profile is expressed as a percentage of the maximum illumination power density permitted under Part J7.\nThe air-conditioning profile is expressed as the plant status.\nTable S35C2c Weekday occupancy and operation profiles of a Class 5 building, a Class 7 warehouse, a Class 8 Laboratory or a Class 9a clinic, day surgery or procedure unit\nTime period (local standard time)\nOccupancy (Monday to Friday)\nArtificial lighting (Monday to Friday)\nAppliances and equipment (Monday to Friday)\nAir-conditioning (Monday to Friday)\n12:00am to 1:00am\n0%\n0%\n25%\nOff\n1:00am to 2:00am\n0%\n0%\n25%\nOff\n2:00am to 3:00am\n0%\n0%\n25%\nOff\n3:00am to 4:00am\n0%\n0%\n25%\nOff\n4:00am to 5:00am\n0%\n0%\n25%\nOff\n5:00am to 6:00am\n0%\n0%\n25%\nOff\n6:00am to 7:00am\n0%\n0%\n25%\nOff\n7:00am to 8:00am\n10%\n40%\n65%\nOn\n8:00am to 9:00am\n20%\n90%\n80%\nOn\n9:00am to 10:00am\n70%\n100%\n100%\nOn\n10:00am to 11:00am\n70%\n100%\n100%\nOn\n11:00am to 12:00pm\n70%\n100%\n100%\nOn\n12:00pm to 1:00pm\n70%\n100%\n100%\nOn\n1:00pm to 2:00pm\n70%\n100%\n100%\nOn\n2:00pm to 3:00pm\n70%\n100%\n100%\nOn\n3:00pm to 4:00pm\n70%\n100%\n100%\nOn\n4:00pm to 5:00pm\n70%\n100%\n100%\nOn\n5:00pm to 6:00pm\n35%\n80%\n80%\nOn\n6:00pm to 7:00pm\n10%\n60%\n65%\nOff\n7:00pm to 8:00pm\n5%\n60%\n55%\nOff\n8:00pm to 9:00pm\n5%\n50%\n25%\nOff\n9:00pm to 10:00pm\n0%\n0%\n25%\nOff\n10:00pm to 11:00pm\n0%\n0%\n25%\nOff\n11:00pm to 12:00am\n0%\n0%\n25%\nOff\nTable Notes\nThe occupancy profile is expressed as a percentage of the maximum number of people that can be accommodated in the building.\nThe artificial lighting profile is expressed as a percentage of the maximum illumination power density permitted under Part J7.\nThe appliances and equipment profile is expressed as a percentage of the maximum internal heat gain in Table S35C2l.\nThe air-conditioning profile is expressed as the plant status.\nTable S35C2d Weekend occupancy and operation profiles of a Class 5 building, a Class 7 warehouse, a Class 8 Laboratory or a Class 9a clinic, day surgery or procedure unit\nTime period (local standard time)\nOccupancy (Saturday, Sunday and holidays)\nArtificial lighting (Saturday, Sunday and holidays)\nAppliances and equipment (Saturday, Sunday and holidays)\nAir-conditioning (Saturday, Sunday and holidays)\n12:00am to 1:00am\n0%\n0%\n25%\nOff\n1:00am to 2:00am\n0%\n0%\n25%\nOff\n2:00am to 3:00am\n0%\n0%\n25%\nOff\n3:00am to 4:00am\n0%\n0%\n25%\nOff\n4:00am to 5:00am\n0%\n0%\n25%\nOff\n5:00am to 6:00am\n0%\n0%\n25%\nOff\n6:00am to 7:00am\n0%\n0%\n25%\nOff\n7:00am to 8:00am\n0%\n0%\n25%\nOff\n8:00am to 9:00am\n5%\n15%\n25%\nOff\n9:00am to 10:00am\n5%\n15%\n25%\nOff\n10:00am to 11:00am\n5%\n15%\n25%\nOff\n11:00am to 12:00pm\n5%\n15%\n25%\nOff\n12:00pm to 1:00pm\n5%\n15%\n25%\nOff\n1:00pm to 2:00pm\n5%\n15%\n25%\nOff\n2:00pm to 3:00pm\n5%\n15%\n25%\nOff\n3:00pm to 4:00pm\n5%\n15%\n25%\nOff\n4:00pm to 5:00pm\n5%\n15%\n25%\nOff\n5:00pm to 6:00pm\n0%\n0%\n25%\nOff\n6:00pm to 7:00pm\n0%\n0%\n25%\nOff\n7:00pm to 8:00pm\n0%\n0%\n25%\nOff\n8:00pm to 9:00pm\n0%\n0%\n25%\nOff\n9:00pm to 10:00pm\n0%\n0%\n25%\nOff\n10:00pm to 11:00pm\n0%\n0%\n25%\nOff\n11:00pm to 12:00am\n0%\n0%\n25%\nOff\nTable Notes\nThe occupancy profile is expressed as a percentage of the maximum number of people that can be accommodated in the building.\nThe artificial lighting profile is expressed as a percentage of the maximum illumination power density permitted under Part J7.\nThe appliances and equipment profile is expressed as a percentage of the maximum internal heat gain in Table S35C2l.\nThe air-conditioning profile is expressed as the plant status.\nTable S35C2e Occupancy and operation profiles of a Class 6 shop or shopping centre\nTime period (local standard time)\nOccupancy (Daily)\nArtificial lighting (Daily)\nAppliances and equipment (Daily)\nAir-conditioning (Daily)\n12:00am to 1:00am\n0%\n0%\n25%\nOff\n1:00am to 2:00am\n0%\n0%\n25%\nOff\n2:00am to 3:00am\n0%\n0%\n25%\nOff\n3:00am to 4:00am\n0%\n0%\n25%\nOff\n4:00am to 5:00am\n0%\n0%\n25%\nOff\n5:00am to 6:00am\n0%\n0%\n25%\nOff\n6:00am to 7:00am\n0%\n0%\n25%\nOff\n7:00am to 8:00am\n10%\n100%\n70%\nOn\n8:00am to 9:00am\n20%\n100%\n70%\nOn\n9:00am to 10:00am\n20%\n100%\n70%\nOn\n10:00am to 11:00am\n15%\n100%\n70%\nOn\n11:00am to 12:00pm\n25%\n100%\n70%\nOn\n12:00pm to 1:00pm\n25%\n100%\n70%\nOn\n1:00pm to 2:00pm\n20%\n100%\n70%\nOn\n2:00pm to 3:00pm\n20%\n100%\n70%\nOn\n3:00pm to 4:00pm\n20%\n100%\n70%\nOn\n4:00pm to 5:00pm\n20%\n100%\n70%\nOn\n5:00pm to 6:00pm\n5%\n100%\n70%\nOn\n6:00pm to 7:00pm\n5%\n100%\n70%\nOff\n7:00pm to 8:00pm\n0%\n0%\n10%\nOff\n8:00pm to 9:00pm\n0%\n0%\n10%\nOff\n9:00pm to 10:00pm\n0%\n0%\n10%\nOff\n10:00pm to 11:00pm\n0%\n0%\n10%\nOff\n11:00pm to 12:00am\n0%\n0%\n10%\nOff\nTable Notes\nThe occupancy profile is expressed as a percentage of the maximum number of people that can be accommodated in the building.\nThe artificial lighting profile is expressed as a percentage of the maximum illumination power density permitted under Part J7.\nThe appliances and equipment profile is expressed as a percentage of the maximum internal heat gain in S35C2l.\nThe air-conditioning profile is expressed as the plant status.\nTable S35C2f Occupancy and operation profiles of a Class 6 restaurant or cafe\nTime period (local standard time)\nOccupancy (Monday to Saturday)\nArtificial lighting (Monday to Saturday)\nAppliances and equipment (Monday to Saturday)\nAir-conditioning (Monday to Saturday)\n12:00am to 1:00am\n0%\n5%\n15%\nOff\n1:00am to 2:00am\n0%\n5%\n15%\nOff\n2:00am to 3:00am\n0%\n5%\n15%\nOff\n3:00am to 4:00am\n0%\n5%\n15%\nOff\n4:00am to 5:00am\n0%\n5%\n15%\nOff\n5:00am to 6:00am\n0%\n5%\n15%\nOff\n6:00am to 7:00am\n5%\n40%\n40%\nOff\n7:00am to 8:00am\n5%\n40%\n40%\nOn\n8:00am to 9:00am\n5%\n60%\n60%\nOn\n9:00am to 10:00am\n5%\n60%\n60%\nOn\n10:00am to 11:00am\n20%\n90%\n90%\nOn\n11:00am to 12:00pm\n50%\n90%\n90%\nOn\n12:00pm to 1:00pm\n80%\n90%\n90%\nOn\n1:00pm to 2:00pm\n70%\n90%\n90%\nOn\n2:00pm to 3:00pm\n40%\n90%\n90%\nOn\n3:00pm to 4:00pm\n20%\n90%\n90%\nOn\n4:00pm to 5:00pm\n25%\n90%\n90%\nOn\n5:00pm to 6:00pm\n50%\n90%\n90%\nOn\n6:00pm to 7:00pm\n80%\n90%\n90%\nOn\n7:00pm to 8:00pm\n80%\n90%\n90%\nOn\n8:00pm to 9:00pm\n80%\n90%\n90%\nOn\n9:00pm to 10:00pm\n50%\n90%\n90%\nOn\n10:00pm to 11:00pm\n35%\n50%\n50%\nOn\n11:00pm to 12:00am\n20%\n30%\n30%\nOn\nTable Notes\nThe occupancy profile is expressed as a percentage of the maximum number of people that can be accommodated in the building.\nT","g":"/ncc/s35c2","a19":["Spec JVc: 2"]},{"c":"S36C1","t":"Scope","p":"Specification 36 Material properties","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/36-material-properties#S36C1","x":"This Specification lists the thermal properties of some common construction materials.","g":"/ncc/s36c1","a19":["Spec J1.2: 1"]},{"c":"Table S36C2a","t":"Thermal conductivity of typical framing materials","p":"Specification 36 Material properties","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/36-material-properties#_ad6e16f7-5fb5-41b6-ae6d-c77ef0c94fc9","x":"Description | Density (kg/m3) | Thermal conductivity (Wm-1K-1)\nSteel | 7850 | 47.5\nTimber – kiln dried hardwood (across the grain) | 677 | 0.16\nTimber – Radiata pine (across the grain) | 506 | 0.12","tb":"S36C2","g":"/ncc/table-s36c2a"},{"c":"Table S36C2b","t":"Thermal conductivity of typical roof cladding materials","p":"Specification 36 Material properties","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/36-material-properties#_f3afd519-3336-4f0d-970f-935cd3064966","x":"Description | Density (kg/m3) | Thermal conductivity (Wm-1K-1)\nAluminium sheeting | 2680 | 210\nConcrete or terra cotta tiles | 1922 | 0.81\nSteel sheeting | 7850 | 47.5","tb":"S36C2","g":"/ncc/table-s36c2b"},{"c":"Table S36C2c","t":"Thermal conductivity of typical wall cladding materials","p":"Specification 36 Material properties","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/36-material-properties#_ab4ef5b5-8c4f-4772-87a4-4786a5162545","x":"Description | Density (kg/m3) | Thermal conductivity (Wm-1K-1)\nAluminium sheeting | 2680 | 210\nAutoclaved aerated concrete | 350 | 0.10\n510 | 0.15\n900 | 0.27\nCement render (1 part cement to 4 parts sand) | 1570 | 0.53\nClay brick: 2.75 kg | 1430 | 0.55\nClay brick: 3.25 kg | 1690 | 0.65\nClay brick: 3.75 kg | 1950 | 0.78\nConcrete block: 190 mm dense or 90 mm dense solid | 1100/2200 | 1.1\nConcrete block: 140 mm dense or 190 mm lightweight | 1250/910 | 0.85\nConcrete block: 90 mm dense hollow or 90 mm lightweight solid | 1650 / 1800 | 0.75\nConcrete block: 140 mm lightweight | 1050 | 0.67\nConcrete block: 90 mm lightweight | 1360 | 0.55\nFibre-cement | 1360 | 0.25\nGypsum plasterboard | 880 | 0.17\nPine weatherboards | 506 | 0.10\nPlywood | 530 | 0.14\nSolid concrete | 2400 | 1.44\nSteel sheeting | 7850 | 47.5\nPrestressed hollow core concrete panel | 1680 | 0.80","tb":"S36C2","g":"/ncc/table-s36c2c"},{"c":"Table S36C2d","t":"Thermal conductivity of typical flooring materials","p":"Specification 36 Material properties","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/36-material-properties#_783dd476-5586-4200-b1ce-aa48d584770c","x":"Description | Density (kg/m3) | Thermal conductivity (Wm-1K-1)\nCarpet underlay | - | 0.04\nCarpet | - | 0.05\nPrestressed hollow core concrete planks | 1680 | 0.80\nParticleboard | 640 | 0.12\nPlywood | 530 | 0.14\nTimber – kiln dried hardwood (across the grain) | 677 | 0.16\nTimber – Radiata pine (across the grain) | 506 | 0.10\nSolid concrete | 2400 | 1.44\nVinyl floor tiles | 2050 | 0.79","tb":"S36C2","g":"/ncc/table-s36c2d"},{"c":"Table S36C2e","t":"Thermal conductivity of other materials not listed in Tables S36C2a to S36C2d","p":"Specification 36 Material properties","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/36-material-properties#_19784359-07c0-4689-9889-36ea0b118a46","x":"Description | Density (kg/m3) | Thermal conductivity (Wm-1K-1)\nClay soil (10% moisture content) | 1300 | 0.6\nPMMA (polymethylmethacrylate) | 1180 | 1.0\nPolycarbonates | 1200 | 0.2\nSand (6% moisture content) | 1800 | 1.64\nSoda lime glass | 2500 | 1.0","tb":"S36C2","g":"/ncc/table-s36c2e"},{"c":"Table S36C2f","t":"Typical R-Values for air films: surfaces other than outdoor surfaces","p":"Specification 36 Material properties","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/36-material-properties#_c8b5aa7f-abd4-4f4e-9274-42898045db39","x":"Position of air film | Direction of heat flow | R-Value\nOn a surface with a pitch of not more than 5° | Up | 0.11\nDown | 0.16\nOn a surface with a pitch of more than 5° but not more than 30° | Up | 0.11\nDown | 0.15\nOn a surface with a pitch of more than 30° but not more than 45° | Up | 0.11\nDown | 0.13\nOn a wall | Horizontal | 0.12","tb":"S36C2","g":"/ncc/table-s36c2f"},{"c":"Table S36C2g","t":"Typical R-Values for air films: outdoor surfaces","p":"Specification 36 Material properties","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/36-material-properties#_62da9abe-1120-4bcb-ba38-5eaece610e24","x":"Position of air film | Direction of heat flow | R-Value\nAny | Any | 0.03","tb":"S36C2","g":"/ncc/table-s36c2g"},{"c":"Table S36C2h","t":"Typical R-Values for airspaces: non-reflective non-ventilated","p":"Specification 36 Material properties","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/36-material-properties#_cc51d1dc-0a2d-4d6e-bcff-6bb2823559c8","x":"Position of airspace | Direction of heat flow | R-Value\nIn a roof with a pitch not more than 5° or cathedral ceiling with a 20 mm to 50 mm thick roof airspace | Up | 0.15\nDown | 0.15\nIn a roof with a pitch not more than 5° or cathedral ceiling with a more than 50 mm to 300 mm thick roof airspace | Up | 0.15\nDown | 0.17\nIn a roof airspace greater than 300 mm thick or with a horizontal ceiling and a roof pitch more than 5° | Up | 0.18\nDown | 0.28\nIn a wall | Horizontal | 0.16\nTable Notes\nLinear interpolation may be used to calculate the R-Value of the airspace in a roof with an intermediate pitch.\nA non-ventilated airspace in a roof is one with continuous cover, such as metal or sarked tiles, and no specific provision for ventilation.\nR-Values are calculated using AS/NZS 4859.2 based on the following:\nsummer temperatures of 24°C internally and 36°C externally for heat transfer down; and\nwinter temperatures of 18°C internally and 12°C externally for heat transfer up; and\naverage of summer and winter results for horizontal heat transfer (e.g. in walls).\nA non-ventilated airspace in a wall is one where there is no express provision for airflow through it and openings to the external environment do not exceed more than 500 mm2 per metre of length in the horizontal direction.\nA non-ventilated airspace in a wall for the purposes of Note (4) includes a wall with drainage openings or weepholes that are open vertical joints in the outer leaf of a cavity masonry wall, which are not regarded as ventilation openings.","tb":"S36C2","g":"/ncc/table-s36c2h"},{"c":"Table S36C2i","t":"Typical R-Values for airspaces: reflective non-ventilated","p":"Specification 36 Material properties","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/36-material-properties#_e118e8c6-a3bf-4dff-bf0a-b4a913499cf0","x":"Position of airspace | Direction of heat flow | R-Value\nIn a wall with an inner reflective surface of 0.05 emittance and a 20 mm to 100 mm airspace to the wall lining | Horizontal | 0.61\nIn a wall with a central reflective membrane with an inner surface emittance of 0.05 and a 20 mm to 100 mm airspace from the membrane to the wall lining, and an outer anti-glare emittance of 0.08 and a 20 mm to 100 mm airspace to the wall cladding | Horizontal | 1.1\nIn a wall with an outer anti-glare reflective surface of 0.08 emittance and a 20 mm to 100 mm airspace to the wall cladding | Horizontal | 0.53\nTable Notes\nA non-ventilated airspace in a wall is one where there is no express provision for airflow through it and openings to the external environment do not exceed 500 mm2 per metre of length in the horizontal direction.\nA non-ventilated airspace in a wall for the purposes of Note (1) includes a wall with drainage openings or weepholes that are open vertical joints in the outer leaf of a cavity masonry wall, which are not regarded as ventilation openings.\nR-Values are calculated using AS/NZS 4859.2 based on the following:\nsummer temperatures of 24°C internally and 36°C externally for heat transfer down; and\nwinter temperatures of 18°C internally and 12°C externally for heat transfer up; and\naverage of summer and winter results for horizontal heat transfer (e.g. in walls); and\nemittances are normal emittances of bounding surfaces in accordance with AS 4200.1.","tb":"S36C2","g":"/ncc/table-s36c2i"},{"c":"Table S36C2j","t":"Typical R-Values for airspaces: non-reflective ventilated","p":"Specification 36 Material properties","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/36-material-properties#_d18c6b9a-61f1-4718-8a4d-e09504aa61fc","x":"Position of airspace | Direction of heat flow | R-Value\nIn a roof airspace greater than 300 mm thick or with a horizontal ceiling and a pitch more than 5° | Up | Nil\nDown | 0.46","tb":"S36C2","g":"/ncc/table-s36c2j"},{"c":"Table S36C2k","t":"Typical R-Values for roof spaces with a reflective surface: Roof space > 300 mm thick or pitched roof with a horizontal ceiling","p":"Specification 36 Material properties","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/36-material-properties#_823b259b-3ff5-4ff2-8b24-706d1928f01f","x":"Direction of heat flow | R-Value of reflective airspace\nVentilated roof space | Non-ventilated roof space\nUp | 0.34 | 0.56\nDown | 1.36 | 1.09\nTable Notes\nA non-ventilated airspace in a roof is one with continuous cover, such as metal or sarked tiles, and no specific provision for ventilation.\nA reflective surface is a surface with normal emittance of 0.05 or less, in accordance with AS 4200.1.","tb":"S36C2","g":"/ncc/table-s36c2k"},{"c":"Table S36C2l","t":"Typical R-Values for non-ventilated roof spaces with a reflective surface: Flat, skillion or pitched roof (≤5°) with horizontal ceiling, roof space not more than 300 mm thick","p":"Specification 36 Material properties","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/36-material-properties#_adcf4e1d-853e-42fe-af93-de0380bebb1f","x":"Emittance of airspace bounding surfaces | Thickness of roof space | Direction of heat flow | R-Value of reflective airspace\nSurface 1 emittance 0.9, Surface 2 emittance 0.05 | ≤ 300 mm | Up | 0.43\nSurface 1 emittance 0.9, Surface 2 emittance 0.05 | 20 mm | Down | 0.60\nSurface 1 emittance 0.9, Surface 2 emittance 0.05 | 60 mm | Down | 1.16\nSurface 1 emittance 0.9, Surface 2 emittance 0.05 | 100 mm to ≤ 300 mm | Down | 1.30\nTable Notes\nA non-ventilated airspace in a roof is one with continuous cover, such as metal, and no specific provision for ventilation.\nLinear interpolation may be used to calculate the R-Value of an airspace of intermediate thickness.\nR-Values are calculated using AS/NZS 4859.2 based on the following:\nsummer temperatures of 24°C internally and 36°C externally for heat transfer down; and\nwinter temperatures of 18°C internally and 12°C externally for heat transfer up; and\nemittances are normal emittances of bounding surfaces in accordance with AS 4200.1.","tb":"S36C2","g":"/ncc/table-s36c2l"},{"c":"Table S36C2m","t":"Typical R-Values for non-ventilated roof spaces with a reflective surface: Pitched roof with cathedral ceiling, roof space not more than 300 mm thick","p":"Specification 36 Material properties","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/36-material-properties#_3b3d1306-30a3-4f22-ab2c-6aca0dac6cbd","x":"Emittance of airspace bounding surfaces | Thickness of roof space | Direction of heat flow | R-Value of reflective airspace\n15° to not more than 25° pitch | more than 25° to not more than 35° pitch | more than 35° to not more than 45° pitch\nSurface 1 emittance 0.9, Surface 2 emittance 0.05 | ≤ 300 mm | Up | 0.43 | 0.43 | 0.43\nSurface 1 emittance 0.9, Surface 2 emittance 0.05 | 20 mm | Down | 0.59 | 0.59 | 0.59\nSurface 1 emittance 0.9, Surface 2 emittance 0.05 | 60 mm | Down | 0.91 | 0.82 | 0.75\nSurface 1 emittance 0.9, Surface 2 emittance 0.05 | 100 mm to ≤ 300 mm | Down | 0.96 | 0.85 | 0.76\nTable Notes\nA non-ventilated airspace in a roof is one with continuous cover, such as metal or sarked tiles, and no specific provision for ventilation.\nLinear interpolation may be used to calculate the R-Value of the airspace in a roof with an intermediate pitch and thickness.\nR-Values are calculated using AS/NZS 4859.2 based on the following:\nsummer temperatures of 24°C internally and 36°C externally for heat transfer down; and\nwinter temperatures of 18°C internally and 12°C externally for heat transfer up; and\nemittances are normal emittances of bounding surfaces in accordance with AS 4200.1.","tb":"S36C2","g":"/ncc/table-s36c2m"},{"c":"S36C2","t":"Construction Deemed-to-Satisfy","p":"Specification 36 Material properties","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/36-material-properties#S36C2","x":"(1) Tables S36C2a, S36C2b, S36C2c, S36C2d and S36C2e list the thermal conductivity considered to be achieved by some common construction materials.\n(2) For the purposes of Tables S36C2a, S36C2b, S36C2c, S36C2d and S36C2e:\nFor materials which incorporate cores or hollows in regular patterns (such as cored brickwork, hollow blockwork and cored floor or wall panels), the tabulated material densities and thermal conductivities are based on the gross density (mass divided by external dimensions).\nThe R-Value of a material is determined by dividing the thickness of the material in metres by the thermal conductivity in Wm-1K-1.\n(3) Tables S36C2f, S36C2g, S36C2h, S36C2i, S36C2j, S36C2k, S36C2l and S36C2m list the R-Value considered to be achieved by air films and airspaces.\n(4) For an envelope that contains a ventilated airspace, the Total R-Value of the building fabric must be reduced based on the area of ventilation openings in accordance with clause 6.3 of AS/NZS 4859.2.\n(5) The requirements of (4) do not apply to a roof with an airspace greater than 300 mm or a pitched roof greater than 5° with a horizontal ceiling.\nTable S36C2a Thermal conductivity of typical framing materials\nDescription\nDensity (kg/m3)\nThermal conductivity (Wm-1K-1)\nSteel\n7850\n47.5\nTimber – kiln dried hardwood (across the grain)\n677\n0.16\nTimber – Radiata pine (across the grain)\n506\n0.12\nTable S36C2b Thermal conductivity of typical roof cladding materials\nDescription\nDensity (kg/m3)\nThermal conductivity (Wm-1K-1)\nAluminium sheeting\n2680\n210\nConcrete or terra cotta tiles\n1922\n0.81\nSteel sheeting\n7850\n47.5\nTable S36C2c Thermal conductivity of typical wall cladding materials\nDescription\nDensity (kg/m3)\nThermal conductivity (Wm-1K-1)\nAluminium sheeting\n2680\n210\nAutoclaved aerated concrete\n350\n0.10\n510\n0.15\n900\n0.27\nCement render (1 part cement to 4 parts sand)\n1570\n0.53\nClay brick: 2.75 kg\n1430\n0.55\nClay brick: 3.25 kg\n1690\n0.65\nClay brick: 3.75 kg\n1950\n0.78\nConcrete block: 190 mm dense or 90 mm dense solid\n1100/2200\n1.1\nConcrete block: 140 mm dense or 190 mm lightweight\n1250/910\n0.85\nConcrete block: 90 mm dense hollow or 90 mm lightweight solid\n1650 / 1800\n0.75\nConcrete block: 140 mm lightweight\n1050\n0.67\nConcrete block: 90 mm lightweight\n1360\n0.55\nFibre-cement\n1360\n0.25\nGypsum plasterboard\n880\n0.17\nPine weatherboards\n506\n0.10\nPlywood\n530\n0.14\nSolid concrete\n2400\n1.44\nSteel sheeting\n7850\n47.5\nPrestressed hollow core concrete panel\n1680\n0.80\nTable S36C2d Thermal conductivity of typical flooring materials\nDescription\nDensity (kg/m3)\nThermal conductivity (Wm-1K-1)\nCarpet underlay\n-\n0.04\nCarpet\n-\n0.05\nPrestressed hollow core concrete planks\n1680\n0.80\nParticleboard\n640\n0.12\nPlywood\n530\n0.14\nTimber – kiln dried hardwood (across the grain)\n677\n0.16\nTimber – Radiata pine (across the grain)\n506\n0.10\nSolid concrete\n2400\n1.44\nVinyl floor tiles\n2050\n0.79\nTable S36C2e Thermal conductivity of other materials not listed in Tables S36C2a to S36C2d\nDescription\nDensity (kg/m3)\nThermal conductivity (Wm-1K-1)\nClay soil (10% moisture content)\n1300\n0.6\nPMMA (polymethylmethacrylate)\n1180\n1.0\nPolycarbonates\n1200\n0.2\nSand (6% moisture content)\n1800\n1.64\nSoda lime glass\n2500\n1.0\nTable S36C2f Typical R-Values for air films: surfaces other than outdoor surfaces\nPosition of air film\nDirection of heat flow\nR-Value\nOn a surface with a pitch of not more than 5°\nUp\n0.11\nDown\n0.16\nOn a surface with a pitch of more than 5° but not more than 30°\nUp\n0.11\nDown\n0.15\nOn a surface with a pitch of more than 30° but not more than 45°\nUp\n0.11\nDown\n0.13\nOn a wall\nHorizontal\n0.12\nTable S36C2g Typical R-Values for air films: outdoor surfaces\nPosition of air film\nDirection of heat flow\nR-Value\nAny\nAny\n0.03\nTable S36C2h Typical R-Values for airspaces: non-reflective non-ventilated\nPosition of airspace\nDirection of heat flow\nR-Value\nIn a roof with a pitch not more than 5° or cathedral ceiling with a 20 mm to 50 mm thick roof airspace\nUp\n0.15\nDown\n0.15\nIn a roof with a pitch not more than 5° or cathedral ceiling with a more than 50 mm to 300 mm thick roof airspace\nUp\n0.15\nDown\n0.17\nIn a roof airspace greater than 300 mm thick or with a horizontal ceiling and a roof pitch more than 5°\nUp\n0.18\nDown\n0.28\nIn a wall\nHorizontal\n0.16\nTable Notes\nLinear interpolation may be used to calculate the R-Value of the airspace in a roof with an intermediate pitch.\nA non-ventilated airspace in a roof is one with continuous cover, such as metal or sarked tiles, and no specific provision for ventilation.\nR-Values are calculated using AS/NZS 4859.2 based on the following:\nsummer temperatures of 24°C internally and 36°C externally for heat transfer down; and\nwinter temperatures of 18°C internally and 12°C externally for heat transfer up; and\naverage of summer and winter results for horizontal heat transfer (e.g. in walls).\nA non-ventilated airspace in a wall is one where there is no express provision for airflow through it and openings to the external environment do not exceed more than 500 mm2 per metre of length in the horizontal direction.\nA non-ventilated airspace in a wall for the purposes of Note (4) includes a wall with drainage openings or weepholes that are open vertical joints in the outer leaf of a cavity masonry wall, which are not regarded as ventilation openings.\nTable S36C2i Typical R-Values for airspaces: reflective non-ventilated\nPosition of airspace\nDirection of heat flow\nR-Value\nIn a wall with an inner reflective surface of 0.05 emittance and a 20 mm to 100 mm airspace to the wall lining\nHorizontal\n0.61\nIn a wall with a central reflective membrane with an inner surface emittance of 0.05 and a 20 mm to 100 mm airspace from the membrane to the wall lining, and an outer anti-glare emittance of 0.08 and a 20 mm to 100 mm airspace to the wall cladding\nHorizontal\n1.1\nIn a wall with an outer anti-glare reflective surface of 0.08 emittance and a 20 mm to 100 mm airspace to the wall cladding\nHorizontal\n0.53\nTable Notes\nA non-ventilated airspace in a wall is one where there is no express provision for airflow through it and openings to the external environment do not exceed 500 mm2 per metre of length in the horizontal direction.\nA non-ventilated airspace in a wall for the purposes of Note (1) includes a wall with drainage openings or weepholes that are open vertical joints in the outer leaf of a cavity masonry wall, which are not regarded as ventilation openings.\nR-Values are calculated using AS/NZS 4859.2 based on the following:\nsummer temperatures of 24°C internally and 36°C externally for heat transfer down; and\nwinter temperatures of 18°C internally and 12°C externally for heat transfer up; and\naverage of summer and winter results for horizontal heat transfer (e.g. in walls); and\nemittances are normal emittances of bounding surfaces in accordance with AS 4200.1.\nTable S36C2j Typical R-Values for airspaces: non-reflective ventilated\nPosition of airspace\nDirection of heat flow\nR-Value\nIn a roof airspace greater than 300 mm thick or with a horizontal ceiling and a pitch more than 5°\nUp\nNil\nDown\n0.46\nTable S36C2k Typical R-Values for roof spaces with a reflective surface: Roof space > 300 mm thick or pitched roof with a horizontal ceiling\nDirection of heat flow\nR-Value of reflective airspace\nVentilated roof space\nNon-ventilated roof space\nUp\n0.34\n0.56\nDown\n1.36\n1.09\nTable Notes\nA non-ventilated airspace in a roof is one with continuous cover, such as metal or sarked tiles, and no specific provision for ventilation.\nA reflective surface is a surface with normal emittance of 0.05 or less, in accordance with AS 4200.1.\nTable S36C2l Typical R-Values for non-ventilated roof spaces with a reflective surface: Flat, skillion or pitched roof (≤5°) with horizontal ceiling, roof space not more than 300 mm thick\nEmittance of airspace bounding surfaces\nThickness of roof space\nDirection of heat flow\nR-Value of reflective airspace\nSurface 1 emittance 0.9, Surface 2 emittance 0.05\n≤ 300 mm\nUp\n0.43\nSurface 1 emittance 0.9, Surface 2 emittance 0.05\n20 mm\nDown\n0.60\n","g":"/ncc/s36c2","a19":["Spec J1.2: 2"]},{"c":"S37C1","t":"Scope","p":"Specification 37 Calculation of U-Value and solar admittance","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/37-calculation-u-value-and-solar-admittance#S37C1","x":"This specification describes the methods of calculating the U-Value and solar admittance of a wall-glazing construction.","g":"/ncc/s37c1","a19":["Spec J1.5a: 1"]},{"c":"S37C2","t":"General","p":"Specification 37 Calculation of U-Value and solar admittance","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/37-calculation-u-value-and-solar-admittance#S37C2","x":"For determining the aspect of a wall-glazing construction —\nthe northern aspect is within 45° of true north; and\nthe southern aspect is within 45° of true south; and\nthe eastern aspect is within 45° of true east; and\nthe western aspect is within 45° of true west.","g":"/ncc/s37c2","a19":["Spec J1.5a: 2"]},{"c":"S37C3","t":"U-Value — Method 1 (Single Aspect)","p":"Specification 37 Calculation of U-Value and solar admittance","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/37-calculation-u-value-and-solar-admittance#S37C3","x":"(1) For the purposes of this method, a wall-glazing construction only includes the walls and glazing facing a single aspect.\n(2) The Total System U-Value of the wall component of a wall-glazing construction must be calculated as the inverse of the Total R-Value, including allowance for thermal bridging, in accordance with—\nAS/NZS 4859.2; or\nSpecification 38 for spandrel panels.\n(3) The Total System U-Value of a wall-glazing construction must be calculated as the area-weighted average of the Total System U-Value of each of the components of the wall-glazing construction.","g":"/ncc/s37c3","a19":["Spec J1.5a: 3"]},{"c":"S37C4","t":"U-Value — Method 2 (Multiple Aspects)","p":"Specification 37 Calculation of U-Value and solar admittance","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/37-calculation-u-value-and-solar-admittance#S37C4","x":"(1) For the purposes of this method, a wall-glazing construction only includes the walls and glazing facing multiple aspects.\n(2) The Total System U-Value of the wall component of a wall-glazing construction must be calculated as the inverse of the Total R-Value, including allowance for thermal bridging, in accordance with—\nAS/NZS 4859.2; or\nSpecification 38 for spandrel panels.\n(3) The Total System U-Value of a wall-glazing construction must be calculated as the area-weighted average of the Total System U-Value of each of the components of the wall-glazing construction.","g":"/ncc/s37c4","a19":["Spec J1.5a: 4"]},{"c":"S37C5","t":"Solar admittance — Method 1 (Single Aspect)","p":"Specification 37 Calculation of U-Value and solar admittance","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/37-calculation-u-value-and-solar-admittance#S37C5","x":"(1) The solar admittance of a wall-glazing construction must be calculated in accordance with the following formula:\n[formula] (2) In the formula at (1)—\n[formula] = the wall-glazing construction solar admittance; and\n[formula] = the area of each glazing element; and\n[formula] = the shading multiplier for each glazing element in accordance with S37C7; and\n[formula] = the total system SHGC of each glazing element; and\n[formula] = the total wall-glazing construction area.","g":"/ncc/s37c5","a19":["Spec J1.5a: 5"]},{"c":"Table S37C6a","t":"Solar admittance weighting coefficient — Class 5, 6, 7, 8 or 9b building or Class 9a building other than a ward area","p":"Specification 37 Calculation of U-Value and solar admittance","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/37-calculation-u-value-and-solar-admittance#_e63fe87c-aaa2-42e3-8316-0865d17f9e25","x":"Aspect | Climate zone 1 | Climate zone 2 | Climate zone 3 | Climate zone 4 | Climate zone 5 | Climate zone 6 | Climate zone 7 | Climate zone 8\nNorthern | 1.47 | 1.95 | 1.95 | 2.05 | 2.28 | 2.12 | 2.40 | 1.88\nSouthern | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00\nEastern | 1.39 | 1.58 | 1.63 | 1.72 | 1.72 | 1.62 | 1.84 | 1.92\nWestern | 1.41 | 1.68 | 1.65 | 1.69 | 1.75 | 1.67 | 1.92 | 1.25","tb":"S37C6","g":"/ncc/table-s37c6a"},{"c":"Table S37C6b","t":"Solar admittance weighting coefficient — Class 3 or 9c building or Class 9a ward area","p":"Specification 37 Calculation of U-Value and solar admittance","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/37-calculation-u-value-and-solar-admittance#_065c7a30-1b1a-482b-ba38-89b69bf5cad0","x":"Aspect | Climate zone 1 | Climate zone 2 | Climate zone 3 | Climate zone 4 | Climate zone 5 | Climate zone 6 | Climate zone 7 | Climate zone 8\nNorthern | 1.42 | 1.77 | 1.72 | 1.55 | 1.88 | 1.52 | 1.60 | 1.24\nSouthern | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00\nEastern | 1.30 | 1.49 | 1.48 | 1.37 | 1.48 | 1.28 | 1.35 | 1.26\nWestern | 1.37 | 1.54 | 1.50 | 1.36 | 1.52 | 1.33 | 1.40 | 1.05","tb":"S37C6","g":"/ncc/table-s37c6b"},{"c":"S37C6","t":"Solar admittance — Method 2 (Multiple Aspects)","p":"Specification 37 Calculation of U-Value and solar admittance","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/37-calculation-u-value-and-solar-admittance#S37C6","x":"(1) The solar admittance of wall-glazing construction must achieve a representative air-conditioning energy value less than that achieved by the reference solar admittance, when using the following formula:\n[formula] (2) In the formula at (1)—\n[formula] = the representative air-conditioning energy value; and\n[formula] = the area of the wall-glazing construction facing each aspect; and\n[formula] = the solar admittance weighting coefficient of each aspect equal to—\nwhere the glazing area on an aspect is less than 20% of the wall-glazing construction area, 0; and\nthe values in Table S37C6a and Table S37C6b; and\n[formula] = the wall-glazing construction solar admittance of each aspect—\nequal to the applicable value in J4D6(5) in the reference case; and\ncalculated in accordance with S37C5(1) in the proposed case.\nTable S37C6a Solar admittance weighting coefficient — Class 5, 6, 7, 8 or 9b building or Class 9a building other than a ward area\nAspect\nClimate zone 1\nClimate zone 2\nClimate zone 3\nClimate zone 4\nClimate zone 5\nClimate zone 6\nClimate zone 7\nClimate zone 8\nNorthern\n1.47\n1.95\n1.95\n2.05\n2.28\n2.12\n2.40\n1.88\nSouthern\n1.00\n1.00\n1.00\n1.00\n1.00\n1.00\n1.00\n1.00\nEastern\n1.39\n1.58\n1.63\n1.72\n1.72\n1.62\n1.84\n1.92\nWestern\n1.41\n1.68\n1.65\n1.69\n1.75\n1.67\n1.92\n1.25\nTable S37C6b Solar admittance weighting coefficient — Class 3 or 9c building or Class 9a ward area\nAspect\nClimate zone 1\nClimate zone 2\nClimate zone 3\nClimate zone 4\nClimate zone 5\nClimate zone 6\nClimate zone 7\nClimate zone 8\nNorthern\n1.42\n1.77\n1.72\n1.55\n1.88\n1.52\n1.60\n1.24\nSouthern\n1.00\n1.00\n1.00\n1.00\n1.00\n1.00\n1.00\n1.00\nEastern\n1.30\n1.49\n1.48\n1.37\n1.48\n1.28\n1.35\n1.26\nWestern\n1.37\n1.54\n1.50\n1.36\n1.52\n1.33\n1.40\n1.05","g":"/ncc/s37c6","a19":["Spec J1.5a: 6"]},{"c":"Table S37C7a","t":"Horizontal shading multipliers — Northern, eastern and western aspects","p":"Specification 37 Calculation of U-Value and solar admittance","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/37-calculation-u-value-and-solar-admittance#_d70d6719-2248-4c9e-95ce-f8c09d7734ac","x":"G/H | P/H = 0 | P/H = 0.1 | P/H = 0.2 | P/H = 0.3 | P/H = 0.4 | P/H = 0.5 | P/H = 0.6 | P/H = 0.7 | P/H = 0.8 | P/H = 0.9 | P/H = 1\n0 | 1.00 | 0.90 | 0.80 | 0.72 | 0.64 | 0.57 | 0.51 | 0.46 | 0.41 | 0.38 | 0.35\n0.1 | 1.00 | 0.95 | 0.89 | 0.81 | 0.74 | 0.66 | 0.59 | 0.52 | 0.47 | 0.42 | 0.40\n0.2 | 1.00 | 0.98 | 0.94 | 0.89 | 0.82 | 0.75 | 0.68 | 0.62 | 0.56 | 0.51 | 0.47\n0.3 | 1.00 | 1.00 | 0.97 | 0.94 | 0.89 | 0.84 | 0.78 | 0.72 | 0.66 | 0.61 | 0.57\n0.4 | 1.00 | 1.00 | 0.99 | 0.97 | 0.94 | 0.90 | 0.86 | 0.82 | 0.77 | 0.73 | 0.68\n0.5 | 1.00 | 1.00 | 1.00 | 0.99 | 0.97 | 0.95 | 0.92 | 0.90 | 0.86 | 0.83 | 0.79","tb":"S37C7","g":"/ncc/table-s37c7a"},{"c":"Table S37C7b","t":"Horizontal shading multipliers — Southern aspect","p":"Specification 37 Calculation of U-Value and solar admittance","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/37-calculation-u-value-and-solar-admittance#_a8660d13-6c90-46d8-9764-5bf15ac0b1c0","x":"G/H | P/H = 0 | P/H = 0.1 | P/H = 0.2 | P/H = 0.3 | P/H = 0.4 | P/H = 0.5 | P/H = 0.6 | P/H = 0.7 | P/H = 0.8 | P/H = 0.9 | P/H = 1\n0 | 1.00 | 0.93 | 0.87 | 0.82 | 0.77 | 0.73 | 0.69 | 0.65 | 0.62 | 0.60 | 0.58\n0.1 | 1.00 | 0.97 | 0.93 | 0.88 | 0.84 | 0.79 | 0.75 | 0.71 | 0.67 | 0.64 | 0.62\n0.2 | 1.00 | 0.98 | 0.96 | 0.93 | 0.89 | 0.85 | 0.81 | 0.77 | 0.73 | 0.70 | 0.68\n0.3 | 1.00 | 0.99 | 0.98 | 0.96 | 0.93 | 0.90 | 0.87 | 0.83 | 0.80 | 0.77 | 0.74\n0.4 | 1.00 | 1.00 | 0.99 | 0.98 | 0.96 | 0.94 | 0.91 | 0.89 | 0.86 | 0.84 | 0.81\n0.5 | 1.00 | 1.00 | 0.99 | 0.99 | 0.98 | 0.96 | 0.95 | 0.93 | 0.91 | 0.90 | 0.88","tb":"S37C7","g":"/ncc/table-s37c7b"},{"c":"Table S37C7c","t":"Vertical shading multipliers — Northern aspect","p":"Specification 37 Calculation of U-Value and solar admittance","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/37-calculation-u-value-and-solar-admittance#_35057608-b8a2-406a-a50a-034005c14a58","x":"Climate zone | D | W = 1.7 H | W = H | W = 0.7 H | W = 0.5 H\n1, 2, 3, 5, 6 | 0.1 W | 0.91 | 0.90 | 0.90 | 0.90\n1, 2, 3, 5, 6 | 0.3 W | 0.85 | 0.83 | 0.82 | 0.81\n1, 2, 3, 5, 6 | 0.5 W | 0.82 | 0.78 | 0.76 | 0.74\n1, 2, 3, 5, 6 | 0.7 W | 0.81 | 0.76 | 0.73 | 0.70\n4 | 0.1 W | 0.91 | 0.91 | 0.90 | 0.90\n4 | 0.3 W | 0.87 | 0.84 | 0.83 | 0.82\n4 | 0.5 W | 0.84 | 0.80 | 0.78 | 0.76\n4 | 0.7 W | 0.83 | 0.78 | 0.75 | 0.73\n7 | 0.1 W | 0.92 | 0.91 | 0.91 | 0.90\n7 | 0.3 W | 0.87 | 0.85 | 0.83 | 0.82\n7 | 0.5 W | 0.86 | 0.82 | 0.79 | 0.78\n7 | 0.7 W | 0.85 | 0.80 | 0.78 | 0.75\n8 | 0.1 W | 0.92 | 0.92 | 0.91 | 0.91\n8 | 0.3 W | 0.90 | 0.88 | 0.86 | 0.85\n8 | 0.5 W | 0.91 | 0.87 | 0.85 | 0.83\n8 | 0.7 W | 0.91 | 0.88 | 0.86 | 0.84","tb":"S37C7","g":"/ncc/table-s37c7c"},{"c":"Table S37C7d","t":"Vertical shading multipliers — Western aspect","p":"Specification 37 Calculation of U-Value and solar admittance","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/37-calculation-u-value-and-solar-admittance#_98a4b592-93e1-4300-9d3d-518686fbe92e","x":"Climate zone | D | W = 1.7 H | W = H | W = 0.7 H | W = 0.5 H\n1, 2, 3, 5, 6 | 0.1 W | 0.93 | 0.91 | 0.90 | 0.90\n1, 2, 3, 5, 6 | 0.3 W | 0.87 | 0.85 | 0.84 | 0.84\n1, 2, 3, 5, 6 | 0.5 W | 0.85 | 0.82 | 0.80 | 0.79\n1, 2, 3, 5, 6 | 0.7 W | 0.83 | 0.79 | 0.77 | 0.75\n4 | 0.1 W | 0.93 | 0.90 | 0.90 | 0.89\n4 | 0.3 W | 0.88 | 0.86 | 0.85 | 0.84\n4 | 0.5 W | 0.87 | 0.84 | 0.82 | 0.81\n4 | 0.7 W | 0.86 | 0.83 | 0.81 | 0.79\n7 | 0.1 W | 0.96 | 0.95 | 0.95 | 0.95\n7 | 0.3 W | 0.94 | 0.94 | 0.94 | 0.93\n7 | 0.5 W | 0.94 | 0.93 | 0.93 | 0.93\n7 | 0.7 W | 0.94 | 0.93 | 0.93 | 0.92\n8 | 0.1 W | 0.93 | 0.90 | 0.89 | 0.89\n8 | 0.3 W | 0.90 | 0.88 | 0.87 | 0.87\n8 | 0.5 W | 0.90 | 0.88 | 0.87 | 0.86\n8 | 0.7 W | 0.90 | 0.89 | 0.87 | 0.86","tb":"S37C7","g":"/ncc/table-s37c7d"},{"c":"Table S37C7e","t":"Vertical shading multipliers — Eastern aspect","p":"Specification 37 Calculation of U-Value and solar admittance","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/37-calculation-u-value-and-solar-admittance#_70ef062c-9131-4472-929a-94dc78d5ce63","x":"Climate zone | D | W = 1.7 H | W = H | W = 0.7 H | W = 0.5 H\n1, 2, 3, 5, 6 | 0.1 W | 0.94 | 0.94 | 0.93 | 0.93\n1, 2, 3, 5, 6 | 0.3 W | 0.90 | 0.89 | 0.88 | 0.87\n1, 2, 3, 5, 6 | 0.5 W | 0.88 | 0.85 | 0.84 | 0.83\n1, 2, 3, 5, 6 | 0.7 W | 0.87 | 0.83 | 0.81 | 0.79\n4 | 0.1 W | 0.94 | 0.93 | 0.92 | 0.92\n4 | 0.3 W | 0.91 | 0.89 | 0.89 | 0.88\n4 | 0.5 W | 0.90 | 0.88 | 0.86 | 0.85\n4 | 0.7 W | 0.89 | 0.87 | 0.85 | 0.83\n7 | 0.1 W | 0.95 | 0.94 | 0.94 | 0.93\n7 | 0.3 W | 0.91 | 0.92 | 0.91 | 0.91\n7 | 0.5 W | 0.93 | 0.91 | 0.90 | 0.89\n7 | 0.7 W | 0.93 | 0.91 | 0.90 | 0.88\n8 | 0.1 W | 0.94 | 0.93 | 0.93 | 0.92\n8 | 0.3 W | 0.94 | 0.93 | 0.93 | 0.92\n8 | 0.5 W | 0.95 | 0.94 | 0.93 | 0.92\n8 | 0.7 W | 0.95 | 0.95 | 0.94 | 0.93","tb":"S37C7","g":"/ncc/table-s37c7e"},{"c":"S37C7","t":"Shading","p":"Specification 37 Calculation of U-Value and solar admittance","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/37-calculation-u-value-and-solar-admittance#S37C7","x":"For the purpose of calculating solar admittance, the shading multiplier for each glazing element is the lesser of—\nfor shading provided by an external permanent projection that extends horizontally on both sides of the glazing for the same project distance P, as shown in Figure S37C7a —\nthe value in Table S37C7a for shading on the northern, eastern or western aspects; or\nthe value in Table S37C7b for shading on the southern aspect; or\nfor shading provided by an external permanent projection that extends vertically for the height of the glazing for the same projection distance D, as shown in Figure S37C7b —\nthe value in Table S37C7c for shading on the northern aspect; or\nthe value in Table S37C7d for shading on the western aspect; or\nthe value in Table S37C7e for shading on the eastern aspect; or\n1.0 for shading on the southern aspect; or\n0.35 for shading that is provided by an external shading device such as a shutter, blind, vertical or horizontal building screen with blades, battens or slats, which—\nis capable of restricting at least 80% of summer solar radiation; and\nif adjustable, will operate automatically in response to the level of solar radiation.\nTable S37C7a Horizontal shading multipliers — Northern, eastern and western aspects\nG/H\nP/H = 0\nP/H = 0.1\nP/H = 0.2\nP/H = 0.3\nP/H = 0.4\nP/H = 0.5\nP/H = 0.6\nP/H = 0.7\nP/H = 0.8\nP/H = 0.9\nP/H = 1\n0\n1.00\n0.90\n0.80\n0.72\n0.64\n0.57\n0.51\n0.46\n0.41\n0.38\n0.35\n0.1\n1.00\n0.95\n0.89\n0.81\n0.74\n0.66\n0.59\n0.52\n0.47\n0.42\n0.40\n0.2\n1.00\n0.98\n0.94\n0.89\n0.82\n0.75\n0.68\n0.62\n0.56\n0.51\n0.47\n0.3\n1.00\n1.00\n0.97\n0.94\n0.89\n0.84\n0.78\n0.72\n0.66\n0.61\n0.57\n0.4\n1.00\n1.00\n0.99\n0.97\n0.94\n0.90\n0.86\n0.82\n0.77\n0.73\n0.68\n0.5\n1.00\n1.00\n1.00\n0.99\n0.97\n0.95\n0.92\n0.90\n0.86\n0.83\n0.79\nTable S37C7b Horizontal shading multipliers — Southern aspect\nG/H\nP/H = 0\nP/H = 0.1\nP/H = 0.2\nP/H = 0.3\nP/H = 0.4\nP/H = 0.5\nP/H = 0.6\nP/H = 0.7\nP/H = 0.8\nP/H = 0.9\nP/H = 1\n0\n1.00\n0.93\n0.87\n0.82\n0.77\n0.73\n0.69\n0.65\n0.62\n0.60\n0.58\n0.1\n1.00\n0.97\n0.93\n0.88\n0.84\n0.79\n0.75\n0.71\n0.67\n0.64\n0.62\n0.2\n1.00\n0.98\n0.96\n0.93\n0.89\n0.85\n0.81\n0.77\n0.73\n0.70\n0.68\n0.3\n1.00\n0.99\n0.98\n0.96\n0.93\n0.90\n0.87\n0.83\n0.80\n0.77\n0.74\n0.4\n1.00\n1.00\n0.99\n0.98\n0.96\n0.94\n0.91\n0.89\n0.86\n0.84\n0.81\n0.5\n1.00\n1.00\n0.99\n0.99\n0.98\n0.96\n0.95\n0.93\n0.91\n0.90\n0.88\nTable S37C7c Vertical shading multipliers — Northern aspect\nClimate zone\nD\nW = 1.7 H\nW = H\nW = 0.7 H\nW = 0.5 H\n1, 2, 3, 5, 6\n0.1 W\n0.91\n0.90\n0.90\n0.90\n1, 2, 3, 5, 6\n0.3 W\n0.85\n0.83\n0.82\n0.81\n1, 2, 3, 5, 6\n0.5 W\n0.82\n0.78\n0.76\n0.74\n1, 2, 3, 5, 6\n0.7 W\n0.81\n0.76\n0.73\n0.70\n4\n0.1 W\n0.91\n0.91\n0.90\n0.90\n4\n0.3 W\n0.87\n0.84\n0.83\n0.82\n4\n0.5 W\n0.84\n0.80\n0.78\n0.76\n4\n0.7 W\n0.83\n0.78\n0.75\n0.73\n7\n0.1 W\n0.92\n0.91\n0.91\n0.90\n7\n0.3 W\n0.87\n0.85\n0.83\n0.82\n7\n0.5 W\n0.86\n0.82\n0.79\n0.78\n7\n0.7 W\n0.85\n0.80\n0.78\n0.75\n8\n0.1 W\n0.92\n0.92\n0.91\n0.91\n8\n0.3 W\n0.90\n0.88\n0.86\n0.85\n8\n0.5 W\n0.91\n0.87\n0.85\n0.83\n8\n0.7 W\n0.91\n0.88\n0.86\n0.84\nTable S37C7d Vertical shading multipliers — Western aspect\nClimate zone\nD\nW = 1.7 H\nW = H\nW = 0.7 H\nW = 0.5 H\n1, 2, 3, 5, 6\n0.1 W\n0.93\n0.91\n0.90\n0.90\n1, 2, 3, 5, 6\n0.3 W\n0.87\n0.85\n0.84\n0.84\n1, 2, 3, 5, 6\n0.5 W\n0.85\n0.82\n0.80\n0.79\n1, 2, 3, 5, 6\n0.7 W\n0.83\n0.79\n0.77\n0.75\n4\n0.1 W\n0.93\n0.90\n0.90\n0.89\n4\n0.3 W\n0.88\n0.86\n0.85\n0.84\n4\n0.5 W\n0.87\n0.84\n0.82\n0.81\n4\n0.7 W\n0.86\n0.83\n0.81\n0.79\n7\n0.1 W\n0.96\n0.95\n0.95\n0.95\n7\n0.3 W\n0.94\n0.94\n0.94\n0.93\n7\n0.5 W\n0.94\n0.93\n0.93\n0.93\n7\n0.7 W\n0.94\n0.93\n0.93\n0.92\n8\n0.1 W\n0.93\n0.90\n0.89\n0.89\n8\n0.3 W\n0.90\n0.88\n0.87\n0.87\n8\n0.5 W\n0.90\n0.88\n0.87\n0.86\n8\n0.7 W\n0.90\n0.89\n0.87\n0.86\nTable S37C7e Vertical shading multipliers — Eastern aspect\nClimate zone\nD\nW = 1.7 H\nW = H\nW = 0.7 H\nW = 0.5 H\n1, 2, 3, 5, 6\n0.1 W\n0.94\n0.94\n0.93\n0.93\n1, 2, 3, 5, 6\n0.3 W\n0.90\n0.89\n0.88\n0.87\n1, 2, 3, 5, 6\n0.5 W\n0.88\n0.85\n0.84\n0.83\n1, 2, 3, 5, 6\n0.7 W\n0.87\n0.83\n0.81\n0.79\n4\n0.1 W\n0.94\n0.93\n0.92\n0.92\n4\n0.3 W\n0.91\n0.89\n0.89\n0.88\n4\n0.5 W\n0.90\n0.88\n0.86\n0.85\n4\n0.7 W\n0.89\n0.87\n0.85\n0.83\n7\n0.1 W\n0.95\n0.94\n0.94\n0.93\n7\n0.3 W\n0.91\n0.92\n0.91\n0.91\n7\n0.5 W\n0.93\n0.91\n0.90\n0.89\n7\n0.7 W\n0.93\n0.91\n0.90\n0.88\n8\n0.1 W\n0.94\n0.93\n0.93\n0.92\n8\n0.3 W\n0.94\n0.93\n0.93\n0.92\n8\n0.5 W\n0.95\n0.94\n0.93\n0.92\n8\n0.7 W\n0.95\n0.95\n0.94\n0.93\nFigure S37C7a Permanent external horizontal shading – measurement of P, G and H\nFigure S37C7b Permanent external vertical shading – measurement of D, W and H","g":"/ncc/s37c7","a19":["Spec J1.5a: 7"]},{"c":"S38C1","t":"Scope","p":"Specification 38 Spandrel panel thermal performance","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/38-spandrel-panel-thermal-performance#S38C1","x":"This Specification describes methods of determining the thermal performance of spandrel panels.","g":"/ncc/s38c1","a19":["Spec J1.5b: 1"]},{"c":"Table S38C2","t":"Achieved Total R-Value of spandrel panels","p":"Specification 38 Spandrel panel thermal performance","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/38-spandrel-panel-thermal-performance#_187c829d-8d5a-4162-b173-70998f4bb850","x":"Type | No insulation | R0.5 insulation | R1.0 insulation | R1.5 insulation | R2.0 insulation\nConfiguration 1 | 0.3 | 0.39 | 0.42 | 0.44 | 0.45\nConfiguration 2 | 0.35 | 0.41 | 0.43 | 0.44 | 0.45\nConfiguration 3 | 0.84 | 0.96 | 1.03 | 1.07 | 1.09\nConfiguration 4 | 0.91 | 1.00 | 1.05 | 1.09 | 1.11","tb":"S38C2","g":"/ncc/table-s38c2"},{"c":"S38C2","t":"Spandrel panel R-Value: Calculation method 1","p":"Specification 38 Spandrel panel thermal performance","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/38-spandrel-panel-thermal-performance#S38C2","x":"Spandrel panels are deemed to have the thermal properties nominated in Table S38C2, where—\nConfiguration 1 consists of—\na thermally unbroken (bridged) frame; and\na centre of spandrel panel consisting of—\na single-glazed opaque or clear face; and\na 100 mm air gap; and\na 3 mm aluminium, 0.8 mm galvanised steel or zinc back pan; and\nConfiguration 2 consists of—\na thermally unbroken (bridged) frame; and\na centre of spandrel panel consisting of—\na double-glazed opaque face; and\na 50 mm air gap; and\na 3 mm aluminium, 0.8 mm galvanised steel or zinc back pan; and\nConfiguration 3 consists of—\na thermally broken (unbridged) frame; and\na centre of spandrel panel consisting of—\na double-glazed clear face; and\na 50 mm air gap; and\na 3 mm aluminium, 0.8 mm galvanised steel or zinc back pan; and\nConfiguration 4 consists of—\na thermally broken (unbridged) frame; and\na centre of spandrel panel consisting of—\na double-glazed low-e clear face; and\na 50 mm air gap; and\na 3 mm aluminium, 0.8 mm galvanised steel or zinc back pan.\nTable S38C2 Achieved Total R-Value of spandrel panels\nType\nNo insulation\nR0.5 insulation\nR1.0 insulation\nR1.5 insulation\nR2.0 insulation\nConfiguration 1\n0.3\n0.39\n0.42\n0.44\n0.45\nConfiguration 2\n0.35\n0.41\n0.43\n0.44\n0.45\nConfiguration 3\n0.84\n0.96\n1.03\n1.07\n1.09\nConfiguration 4\n0.91\n1.00\n1.05\n1.09\n1.11","g":"/ncc/s38c2","a19":["Spec J1.5b: 2"]},{"c":"S38C3","t":"Spandrel panel R-Value: Calculation method 2","p":"Specification 38 Spandrel panel thermal performance","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/38-spandrel-panel-thermal-performance#S38C3","x":"(1) The Total R-Value of a spandrel panel is determined in accordance with the following formula:\n[formula] (2) In the formula at (1)—\n[formula] = the area of the centre region of the spandrel panel; and\n[formula] = the area of the edge region of the spandrel panel, where the edge has a defined width of 127 mm; and\n[formula] = the area of the frame region of the spandrel panel; and\n[formula] = the U-value of the centre region of the spandrel panel; and\n[formula] = the U-value of the edge region of the spandrel panel, where the edge has a defined width of 127 mm; and\n[formula] = the U-value of the frame region of the spandrel panel; and\n[formula] = the Total R-Value of the spandrel panel.","g":"/ncc/s38c3","a19":["Spec J1.5b: 3"]},{"c":"S39C1","t":"Scope","p":"Specification 39 Sub-floor and soil thermal performance","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/39-sub-floor-and-soil-thermal-performance#S39C1","x":"This Specification describes the thermal performance of sub-floor spaces and soil in direct contact with a floor for the purposes of calculating the Total R-Value of a floor.","g":"/ncc/s39c1","a19":["Spec J1.6: 1"]},{"c":"Table S39C2a","t":"R-Value of sub-floor spaces","p":"Specification 39 Sub-floor and soil thermal performance","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/39-sub-floor-and-soil-thermal-performance#_14cbdc87-3078-452d-918a-ac58959d876f","x":"Ratio of floor area (m2) to floor perimeter (m) | Sub-floor space R-Value\n1.0 | 0.10\n1.5 | 0.15\n2.0 | 0.20\n2.5 | 0.25\n3.0 | 0.30\n3.5 | 0.35\n4.0 | 0.40\n4.5 | 0.45\n5.0 | 0.50\n5.5 | 0.55\n6.0 | 0.60\n6.5 | 0.65\n7.0 | 0.70\nTable Notes\nWhere the ratio of floor area to floor perimeter is between the values stated, interpolation may be used to determine the sub-floor space R-Values.","tb":"S39C2","g":"/ncc/table-s39c2a"},{"c":"Table S39C2b","t":"R-Value of soil in contact with a floor","p":"Specification 39 Sub-floor and soil thermal performance","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/39-sub-floor-and-soil-thermal-performance#_aec93b66-5735-4d7b-9f39-a3d2f7def0a1","x":"Ratio of floor area (m2)  to floor perimeter (m) | Wall thickness of 50 mm | Wall thickness of 100 mm | Wall thickness of 150 mm | Wall thickness of 200 mm | Wall thickness of 250 mm | Wall thickness of 300 mm\n1.0 | 0.4 | 0.5 | 0.5 | 0.6 | 0.7 | 0.8\n1.5 | 0.6 | 0.7 | 0.7 | 0.8 | 0.9 | 1.0\n2.0 | 0.7 | 0.8 | 0.9 | 1.0 | 1.1 | 1.3\n2.5 | 0.9 | 1.0 | 1.1 | 1.2 | 1.3 | 1.5\n3.0 | 1.0 | 1.2 | 1.3 | 1.4 | 1.5 | 1.7\n3.5 | 1.2 | 1.3 | 1.5 | 1.6 | 1.7 | 1.9\n4.0 | 1.3 | 1.5 | 1.6 | 1.7 | 1.9 | 2.2\n4.5 | 1.5 | 1.7 | 1.8 | 1.9 | 2.1 | 2.4\n5.0 | 1.6 | 1.8 | 2.0 | 2.1 | 2.3 | 2.6\n5.5 | 1.8 | 2.0 | 2.1 | 2.2 | 2.4 | 2.8\n6.0 | 1.9 | 2.1 | 2.3 | 2.4 | 2.6 | 2.9\n6.5 | 2.0 | 2.3 | 2.4 | 2.6 | 2.8 | 3.1\n7.0 | 2.2 | 2.4 | 2.6 | 2.7 | 3.0 | 3.3\nTable Notes\nWhere a wall thickness or ratio of floor area to floor perimeter is between the values stated, interpolation may be used to determine the soil R-Value.\nWall thickness means the thickness of the envelope wall that sits on or around the slab.","tb":"S39C2","g":"/ncc/table-s39c2b"},{"c":"S39C2","t":"Sub-floor space and soil thermal performance","p":"Specification 39 Sub-floor and soil thermal performance","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/39-sub-floor-and-soil-thermal-performance#S39C2","x":"(1) Table S39C2a details the R-Values considered to be achieved by enclosed sub-floor spaces that are—\nmechanically ventilated by not more than 1.5 air changes per hour; or\nprovided with not more than 150% of the aggregate sub-floor ventilation area required by Part F1 and are not mechanically ventilated.\n(2) Table S39C2b details the R-Values considered to be achieved by the soil for floors that are in direct contact with the ground.\nTable S39C2a R-Value of sub-floor spaces\nRatio of floor area (m2) to floor perimeter (m)\nSub-floor space R-Value\n1.0\n0.10\n1.5\n0.15\n2.0\n0.20\n2.5\n0.25\n3.0\n0.30\n3.5\n0.35\n4.0\n0.40\n4.5\n0.45\n5.0\n0.50\n5.5\n0.55\n6.0\n0.60\n6.5\n0.65\n7.0\n0.70\nTable Notes\nWhere the ratio of floor area to floor perimeter is between the values stated, interpolation may be used to determine the sub-floor space R-Values.\nTable S39C2b R-Value of soil in contact with a floor\nRatio of floor area (m2)  to floor perimeter (m)\nWall thickness of 50 mm\nWall thickness of 100 mm\nWall thickness of 150 mm\nWall thickness of 200 mm\nWall thickness of 250 mm\nWall thickness of 300 mm\n1.0\n0.4\n0.5\n0.5\n0.6\n0.7\n0.8\n1.5\n0.6\n0.7\n0.7\n0.8\n0.9\n1.0\n2.0\n0.7\n0.8\n0.9\n1.0\n1.1\n1.3\n2.5\n0.9\n1.0\n1.1\n1.2\n1.3\n1.5\n3.0\n1.0\n1.2\n1.3\n1.4\n1.5\n1.7\n3.5\n1.2\n1.3\n1.5\n1.6\n1.7\n1.9\n4.0\n1.3\n1.5\n1.6\n1.7\n1.9\n2.2\n4.5\n1.5\n1.7\n1.8\n1.9\n2.1\n2.4\n5.0\n1.6\n1.8\n2.0\n2.1\n2.3\n2.6\n5.5\n1.8\n2.0\n2.1\n2.2\n2.4\n2.8\n6.0\n1.9\n2.1\n2.3\n2.4\n2.6\n2.9\n6.5\n2.0\n2.3\n2.4\n2.6\n2.8\n3.1\n7.0\n2.2\n2.4\n2.6\n2.7\n3.0\n3.3\nTable Notes\nWhere a wall thickness or ratio of floor area to floor perimeter is between the values stated, interpolation may be used to determine the soil R-Value.\nWall thickness means the thickness of the envelope wall that sits on or around the slab.","g":"/ncc/s39c2","a19":["Spec J1.6: 2"]},{"c":"S40C1","t":"Scope","p":"Specification 40 Lighting and power control devices","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/40-lighting-and-power-control-devices#S40C1","x":"This Specification contains the requirements for lighting and power control devices including manual switches, time switches, demand-operated controls and daylight control devices.","g":"/ncc/s40c1","a19":["Spec J6: 1"]},{"c":"S40C2","t":"Manual switch","p":"Specification 40 Lighting and power control devices","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/40-lighting-and-power-control-devices#S40C2","x":"An artificial lighting manual switch must be located in a visible and easily accessed position—\nin the room or space being switched; or\nin an adjacent room or space from where at least 90% of the lighting being controlled is visible.","g":"/ncc/s40c2","a19":["Spec J6: 2"]},{"c":"S40C3","t":"Time switch","p":"Specification 40 Lighting and power control devices","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/40-lighting-and-power-control-devices#S40C3","x":"(1) A time switch must—\nbe capable of switching on and off electric power at variable pre-programmed times and on variable pre-programmed days; and\nhave the ability to program public holidays at least 1 year ahead.\n(2) A time switch for internal lighting must be capable of being overridden by—\na demand-operated control; or\na manual switch.\n(3) A time switch for external lighting must be capable of being configured to limit the period the system is switched on to between 30 minutes before sunset and 30 minutes after sunrise.\n(4) A time switch for boiling water or chilled water storage units must be capable of being overridden for a maximum period of 2 hours outside normal operating hours.","g":"/ncc/s40c3","a19":["Spec J6: 3"]},{"c":"S40C4","t":"Demand-operated control","p":"Specification 40 Lighting and power control devices","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/40-lighting-and-power-control-devices#S40C4","x":"(1) A demand-operated control must—\nactivate artificial lighting upon detecting the presence or movement of an occupant; and\ndeactivate artificial lighting immediately or after a run-on period not more than 15 minutes after the space is vacated.\n(2) A demand-operated control in a fire-isolated stairway, fire-isolated passageway or fire-isolated ramp must be configured so that a minimum of 30% of the full design illumination is provided when deactivation required by (1)(b) has occurred.\nNotes\nFor the purposes of S40C4, demand-operated controls may detect the presence or movement of an occupant via a motion detector, key card, security system or the like.","g":"/ncc/s40c4","a19":["Spec J6: 4"]},{"c":"S40C5","t":"Daylight sensor and dynamic lighting control device","p":"Specification 40 Lighting and power control devices","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/40-lighting-and-power-control-devices#S40C5","x":"A daylight sensor and dynamic control device for artificial lighting must, in response to the measured level of available daylight in the range 50–1000 lux—\nfor high pressure discharge lights, switch lights on and off with a programmable delay and switching differential; and\nfor all other lights, dim continuously or step lighting output down in not less than 4 steps so that the lowest power setting is less than 50% of full power.","g":"/ncc/s40c5","a19":["Spec J6: 5"]},{"c":"S44C1","t":"Scope","p":"Specification 44 Calculation of heating load limit, cooling load limit and thermal energy load limit","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/44-calculation-heating-load-limit-cooling-load-limit-and-thermal-energy-load-limit#S44C1","x":"This Specification contains the method of calculating the heating load limit, cooling load limit and thermal energy load limit for compliance with J1P2 and H6P1.","g":"/ncc/s44c1"},{"c":"Table S44C2","t":"Area adjustment factors for the heating load limit","p":"Specification 44 Calculation of heating load limit, cooling load limit and thermal energy load limit","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/44-calculation-heating-load-limit-cooling-load-limit-and-thermal-energy-load-limit#_8e234e2a-d550-4019-a5d0-f8dd7fc09f72","x":"Total area of habitable rooms (AH) | Area adjustment factor (FH)\n≤ 50 m2 | 1.37\n> 50 m2 to ≤ 350 m2 |\n> 350 m2 | 0.84","tb":"S44C2","g":"/ncc/table-s44c2"},{"c":"S44C2","t":"Heating load limit","p":"Specification 44 Calculation of heating load limit, cooling load limit and thermal energy load limit","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/44-calculation-heating-load-limit-cooling-load-limit-and-thermal-energy-load-limit#S44C2","x":"The heating load limit of a space, measured in MJ/m2.annum, is equal to the greater of—\n4; and\n[formula] , where—\n[formula] = the total annual heating degree hours of the building location; and\n[formula] = the area adjustment factor for the heating load limit, determined in accordance with Table S44C2.\nTable S44C2 Area adjustment factors for the heating load limit\nTotal area of habitable rooms (AH)\nArea adjustment factor (FH)\n≤ 50 m2\n1.37\n> 50 m2 to ≤ 350 m2\n[formula] | > 350 m2\n0.84","g":"/ncc/s44c2"},{"c":"Table S44C3","t":"Area adjustment factors for the cooling load limit","p":"Specification 44 Calculation of heating load limit, cooling load limit and thermal energy load limit","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/44-calculation-heating-load-limit-cooling-load-limit-and-thermal-energy-load-limit#_4b605271-345a-41d3-a4d1-5e1cc7addc21","x":"Total area of the habitable rooms (AH) | Area adjustment factor (FC)\n≤ 50 m2 | 1.34\n> 50 m2 and ≤ 200 m2 |\n> 200 m2 and ≤ 1000 m2 |\n> 1000 m2 | 0.71","tb":"S44C3","g":"/ncc/table-s44c3"},{"c":"S44C3","t":"Cooling load limit","p":"Specification 44 Calculation of heating load limit, cooling load limit and thermal energy load limit","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/44-calculation-heating-load-limit-cooling-load-limit-and-thermal-energy-load-limit#S44C3","x":"(1) The cooling load limit of a space, measured in MJ/m2.annum, is calculated in accordance with the following formula:\n[formula] (2) In the formula at (1)—\n[formula] = the cooling load limit (MJ/m2.annum); and\n[formula] = the total annual cooling degree hours of the building location; and\n[formula] = the total annual dehumidification gram hours of the building location; and\n[formula] = the area adjustment factor for the cooling load limit, determined in accordance with Table S44C3.\nTable S44C3 Area adjustment factors for the cooling load limit\nTotal area of the habitable rooms (AH)\nArea adjustment factor (FC)\n≤ 50 m2\n1.34\n> 50 m2 and ≤ 200 m2\n[formula] | > 200 m2 and ≤ 1000 m2\n[formula] | > 1000 m2\n0.71","g":"/ncc/s44c3"},{"c":"S44C4","t":"Thermal energy load limit","p":"Specification 44 Calculation of heating load limit, cooling load limit and thermal energy load limit","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/44-calculation-heating-load-limit-cooling-load-limit-and-thermal-energy-load-limit#S44C4","x":"(1) The thermal energy load limit of a space, measured in MJ/m2.annum, is calculated in accordance with the following formula:\n[formula] (2) In the formula at (1)—\n[formula] = the thermal energy load limit; and\n[formula] = the heating load limit; and\n[formula] = the cooling load limit; and\n[formula] = the annual average daily outdoor temperature range.","g":"/ncc/s44c4"},{"c":"S46C1","t":"Scope","p":"Specification 46 Determination of peak efficiency and fan power ratio","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/46-determination-peak-efficiency-and-fan-power-ratio#S46C1","x":"This Specification contains the method of calculating fan power ratio for the purpose of assessing compliance with J6D5.","g":"/ncc/s46c1"},{"c":"S46C2","t":"Determination of peak efficiency and fan power ratio","p":"Specification 46 Determination of peak efficiency and fan power ratio","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/46-determination-peak-efficiency-and-fan-power-ratio#S46C2","x":"(1) The efficiency of a selected fan is the product of its impeller efficiency (including any casing), motor efficiency and the integrated motor control equipment multiplier in (2).\n(2) The value of the integrated motor control equipment multiplier—\nwhere the fan motor is not capable of variable speed operation or has an external variable speed control device, is 1; or\nwhere the fan motor has integrated variable speed control capability and the motor input power at peak efficiency point is less than 5 kW, [formula] , where—\n[formula] = the motor input power of the fan (kW) at peak efficiency point; and\n[formula] = natural logarithm; or\nwhere the fan motor has integrated variable speed control capability and the motor input power at peak efficiency point is greater than or equal to 5 KW, is 1.04.\n(3) The fan power ratio of an individual fan must be calculated in accordance with the following formula:\n[formula] where—\n[formula] = the fan power ratio of the fan; and\n[formula] = the efficiency calculated using the equation at J6D5(2) or J6D5(3) as applicable, with electrical input power [formula] , as determined at (5); and\n[formula] = the static efficiency of the selected fan at the duty point for installation type A or C, or the total efficiency at the duty point for installation type B or D.\n(4) The average fan power ratio of multiple fans must be calculated in accordance with the following formula:\n[formula] where—\n[formula] = the average fan power ratio of multiple fans; and\n[formula] = the electrical input power of each selected fan at duty point, calculated in accordance with (5); and\n[formula] = the electrical input power of each reference fan at duty point, calculated in accordance with (6).\n(5)\n[formula] must be calculated in accordance with the following:\n[formula] where—\n[formula] = the static pressure (Pa) at the duty point for installation type A or C or the total pressure (Pa) at the duty point for installation type B or D; and\n[formula] = the flow (m3/s) at the duty point; and\n[formula] = the static efficiency at the duty point for installation type A or C or the total efficiency at the duty point for installation type B or D.\n(6)\n[formula] must be calculated in accordance with the following formula:\n[formula] where—\n[formula] = the static pressure (Pa) at the duty point for installation type A or C or total pressure (Pa) at the duty point for installation type B or D; and\n[formula] = the flow (m3/s) at the duty point; and\n[formula] = the efficiency calculated using the equation at J6D5(2) or (3) as applicable with electrical input power [formula] .","g":"/ncc/s46c2"},{"c":"S47C1","t":"Scope","p":"Specification 47 Calculation of climate specific part load value for chillers","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/47-calculation-climate-specific-part-load-value-chillers#S47C1","x":"This Specification contains the method to calculate the climate specific part load value for a connected group of chillers that serves a common load, for the purposes of assessing compliance with J6D11.","g":"/ncc/s47c1"},{"c":"Table S47C2a","t":"Load weighting factors - Class 5, 6, 7, 8 or 9b building or Class 9a building other than a ward area","p":"Specification 47 Calculation of climate specific part load value for chillers","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/47-calculation-climate-specific-part-load-value-chillers#_7b31113c-8c42-4a73-af85-1d7540dcc5c1","x":"Load | CZ 1 | CZ 2 | CZ 3 | CZ 4 | CZ 5 | CZ 6 | CZ 7 | CZ 8\n25% | 7% | 25% | 23% | 25% | 24% | 42% | 28% | 20%\n50% | 48% | 43% | 48% | 35% | 46% | 31% | 36% | 27%\n75% | 43% | 31% | 28% | 37% | 30% | 26% | 34% | 42%\n100% | 2% | 1% | 1% | 3% | 0% | 1% | 2% | 11%\nTable Notes\nLoad is the proportion of the total design load served by a connected group of chillers.\nCZ = climate zone.","tb":"S47C2","g":"/ncc/table-s47c2a"},{"c":"Table S47C2b","t":"Load weighting factors - Class 3 or 9c building or Class 9a ward area","p":"Specification 47 Calculation of climate specific part load value for chillers","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/47-calculation-climate-specific-part-load-value-chillers#_e317ae46-50bd-4703-8e85-ad9cf84e7080","x":"Load | CZ 1 | CZ 2 | CZ 3 | CZ 4 | CZ 5 | CZ 6 | CZ 7 | CZ 8\n25% | 7% | 31% | 23% | 43% | 41% | 60% | 40% | 16%\n50% | 31% | 39% | 44% | 39% | 35% | 24% | 31% | 32%\n75% | 61% | 28% | 32% | 18% | 23% | 15% | 26% | 49%\n100% | 1% | 2% | 1% | 0% | 1% | 1% | 3% | 3%\nTable Notes\nLoad is the proportion of the total design load served by a connected group of chillers.\nCZ = climate zone.","tb":"S47C2","g":"/ncc/table-s47c2b"},{"c":"Table S47C2c","t":"Part load evaluation points - outdoor wet bulb temperature (°C), Class 5, 6, 7, 8 or 9b building or Class 9a building other than a ward area","p":"Specification 47 Calculation of climate specific part load value for chillers","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/47-calculation-climate-specific-part-load-value-chillers#_a38d90f5-a1fb-49dc-b02d-41511dc87ae0","x":"Load | CZ 1 | CZ 2 | CZ 3 | CZ 4 | CZ 5 | CZ 6 | CZ 7 | CZ 8\n25% | 17 | 16 | 12 | 12 | 14 | 12 | 12 | 10\n50% | 24 | 22 | 17 | 17 | 20 | 18 | 17 | 13\n75% | 27 | 25 | 21 | 20 | 23 | 20 | 19 | 15\n100% | 28 | 27 | 23 | 22 | 25 | 24 | 21 | 14\nTable Notes\nLoad is the proportion of the total design load served by a connected group of chillers.\nCZ = climate zone.","tb":"S47C2","g":"/ncc/table-s47c2c"},{"c":"Table S47C2d","t":"Part load evaluation points - outdoor wet bulb temperature (°C), Class 3 or 9c building or Class 9a ward area","p":"Specification 47 Calculation of climate specific part load value for chillers","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/47-calculation-climate-specific-part-load-value-chillers#_758d0195-055a-48ca-ba58-cc12e1f35f87","x":"Load | CZ 1 | CZ 2 | CZ 3 | CZ 4 | CZ 5 | CZ 6 | CZ 7 | CZ 8\n25% | 19 | 18 | 12 | 14 | 17 | 14 | 14 | 10\n50% | 24 | 22 | 17 | 18 | 21 | 19 | 17 | 13\n75% | 27 | 25 | 20 | 20 | 23 | 21 | 19 | 14\n100% | 29 | 27 | 24 | 23 | 26 | 23 | 20 | 17\nTable Notes\nLoad is proportion of the total design load served by a connected group of chillers.\nCZ = climate zone.","tb":"S47C2","g":"/ncc/table-s47c2d"},{"c":"Table S47C2e","t":"Part load evaluation points - outdoor dry bulb temperature (°C), Class 5, 6, 7, 8 or 9b building or Class 9a building other than a ward area","p":"Specification 47 Calculation of climate specific part load value for chillers","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/47-calculation-climate-specific-part-load-value-chillers#_94e90838-9023-40f2-a460-b866d0a2e0f9","x":"Load | CZ 1 | CZ 2 | CZ 3 | CZ 4 | CZ 5 | CZ 6 | CZ 7 | CZ 8\n25% | 27 | 21 | 21 | 18 | 19 | 17 | 17 | 14\n50% | 31 | 27 | 32 | 27 | 25 | 26 | 25 | 20\n75% | 32 | 29 | 34 | 31 | 28 | 31 | 29 | 23\n100% | 29 | 29 | 28 | 32 | 27 | 36 | 32 | 25\nTable Notes\nLoad is the proportion of the total design load served by a connected group of chillers.\nCZ = climate zone.","tb":"S47C2","g":"/ncc/table-s47c2e"},{"c":"Table S47C2f","t":"Part load evaluation points - outdoor dry bulb temperature (°C), Class 3 or 9c building or Class 9a ward area","p":"Specification 47 Calculation of climate specific part load value for chillers","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/47-calculation-climate-specific-part-load-value-chillers#_39439549-b597-49d6-bf09-ae89c75ff786","x":"Load | CZ 1 | CZ 2 | CZ 3 | CZ 4 | CZ 5 | CZ 6 | CZ 7 | CZ 8\n25% | 24 | 22 | 21 | 20 | 21 | 19 | 18 | 14\n50% | 29 | 27 | 31 | 29 | 26 | 27 | 26 | 17\n75% | 31 | 29 | 36 | 34 | 29 | 33 | 31 | 22\n100% | 34 | 32 | 39 | 41 | 32 | 41 | 36 | 27\nTable Notes\nLoad is the proportion of the total design load served by a connected group of chillers.\nCZ = climate zone.","tb":"S47C2","g":"/ncc/table-s47c2f"},{"c":"S47C2","t":"Calculation of climate specific part load value for chillers","p":"Specification 47 Calculation of climate specific part load value for chillers","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/47-calculation-climate-specific-part-load-value-chillers#S47C2","x":"(1) The climate specific part load value for a group of one or more chillers must be calculated in accordance with the following formula:\n[formula] where—\n[formula] = climate specific part load value; and\n[formula] = the weighted average energy efficiency ratio of the chillers that operate to provide n% of the design cooling load under the staging strategy to be deployed, determined in accordance with (2) and (3); and\n[formula] = load weighting factors specified in—\nTable S47C2a for chillers serving a Class 5, 6, 7, 8 or 9b building or a Class 9a building other than a ward area; or\nTable S47C2b for chillers serving a Class 3 or 9c building or a Class 9a ward area.\n(2)\n[formula] is determined as the weighted average energy efficiency ratio of the chillers operating to meet n% of the design cooling load under the staging strategy to be deployed, allowing for the part load efficiencies at—\na chilled water leaving temperature of 7°C; and\na chilled water flow rate that corresponds to a 6°C difference between entering and leaving temperatures at the rated cooling capacity, when determined in accordance with AHRI 551/591; and\nfor water-cooled chillers—\na condenser water entering temperature that is determined by adding the design approach temperature to the outside wet bulb temperature listed in—\nTable S47C2c for chillers serving a Class 5, 6, 7, 8 or 9b building or a Class 9a building other than a ward area; or\nTable S47C2d for chillers serving a Class 3 or 9c building or a Class 9a ward area; and\na condenser water flow rate that corresponds to a 6°C difference between entering and leaving temperature at the rated cooling capacity, when determined in accordance with AHRI 551/591; and\nfor air-cooled chillers, the outside dry bulb temperature listed in—\nTable S47C2e for chillers serving a Class 5, 6, 7, 8 or 9b building or a Class 9a building other than a ward area; or\nTable S47C2f for a Class 3 or 9c building or a Class 9a ward area.\n(3)\nThe [formula] values in (2) must be determined using test measurements and calculations performed in accordance with the procedures of AHRI 551/591.\nTable S47C2a Load weighting factors - Class 5, 6, 7, 8 or 9b building or Class 9a building other than a ward area\nLoad\nCZ 1\nCZ 2\nCZ 3\nCZ 4\nCZ 5\nCZ 6\nCZ 7\nCZ 8\n25%\n7%\n25%\n23%\n25%\n24%\n42%\n28%\n20%\n50%\n48%\n43%\n48%\n35%\n46%\n31%\n36%\n27%\n75%\n43%\n31%\n28%\n37%\n30%\n26%\n34%\n42%\n100%\n2%\n1%\n1%\n3%\n0%\n1%\n2%\n11%\nTable Notes\nLoad is the proportion of the total design load served by a connected group of chillers.\nCZ = climate zone.\nTable S47C2b Load weighting factors - Class 3 or 9c building or Class 9a ward area\nLoad\nCZ 1\nCZ 2\nCZ 3\nCZ 4\nCZ 5\nCZ 6\nCZ 7\nCZ 8\n25%\n7%\n31%\n23%\n43%\n41%\n60%\n40%\n16%\n50%\n31%\n39%\n44%\n39%\n35%\n24%\n31%\n32%\n75%\n61%\n28%\n32%\n18%\n23%\n15%\n26%\n49%\n100%\n1%\n2%\n1%\n0%\n1%\n1%\n3%\n3%\nTable Notes\nLoad is the proportion of the total design load served by a connected group of chillers.\nCZ = climate zone.\nTable S47C2c Part load evaluation points - outdoor wet bulb temperature (°C), Class 5, 6, 7, 8 or 9b building or Class 9a building other than a ward area\nLoad\nCZ 1\nCZ 2\nCZ 3\nCZ 4\nCZ 5\nCZ 6\nCZ 7\nCZ 8\n25%\n17\n16\n12\n12\n14\n12\n12\n10\n50%\n24\n22\n17\n17\n20\n18\n17\n13\n75%\n27\n25\n21\n20\n23\n20\n19\n15\n100%\n28\n27\n23\n22\n25\n24\n21\n14\nTable Notes\nLoad is the proportion of the total design load served by a connected group of chillers.\nCZ = climate zone.\nTable S47C2d Part load evaluation points - outdoor wet bulb temperature (°C), Class 3 or 9c building or Class 9a ward area\nLoad\nCZ 1\nCZ 2\nCZ 3\nCZ 4\nCZ 5\nCZ 6\nCZ 7\nCZ 8\n25%\n19\n18\n12\n14\n17\n14\n14\n10\n50%\n24\n22\n17\n18\n21\n19\n17\n13\n75%\n27\n25\n20\n20\n23\n21\n19\n14\n100%\n29\n27\n24\n23\n26\n23\n20\n17\nTable Notes\nLoad is proportion of the total design load served by a connected group of chillers.\nCZ = climate zone.\nTable S47C2e Part load evaluation points - outdoor dry bulb temperature (°C), Class 5, 6, 7, 8 or 9b building or Class 9a building other than a ward area\nLoad\nCZ 1\nCZ 2\nCZ 3\nCZ 4\nCZ 5\nCZ 6\nCZ 7\nCZ 8\n25%\n27\n21\n21\n18\n19\n17\n17\n14\n50%\n31\n27\n32\n27\n25\n26\n25\n20\n75%\n32\n29\n34\n31\n28\n31\n29\n23\n100%\n29\n29\n28\n32\n27\n36\n32\n25\nTable Notes\nLoad is the proportion of the total design load served by a connected group of chillers.\nCZ = climate zone.\nTable S47C2f Part load evaluation points - outdoor dry bulb temperature (°C), Class 3 or 9c building or Class 9a ward area\nLoad\nCZ 1\nCZ 2\nCZ 3\nCZ 4\nCZ 5\nCZ 6\nCZ 7\nCZ 8\n25%\n24\n22\n21\n20\n21\n19\n18\n14\n50%\n29\n27\n31\n29\n26\n27\n26\n17\n75%\n31\n29\n36\n34\n29\n33\n31\n22\n100%\n34\n32\n39\n41\n32\n41\n36\n27\nTable Notes\nLoad is the proportion of the total design load served by a connected group of chillers.\nCZ = climate zone.","g":"/ncc/s47c2"},{"c":"S48C1","t":"Scope","p":"Specification 48 Comparison of zone loads in proposed building and reference building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/48-comparison-zone-loads-proposed-building-and-reference-building#S48C1","x":"This Specification contains the requirements for comparing sensible heating and cooling loads for each assessable zone in the proposed building with the corresponding zones in the reference building.","g":"/ncc/s48c1"},{"c":"S48C2","t":"Comparison of zone loads in proposed building and reference building","p":"Specification 48 Comparison of zone loads in proposed building and reference building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/48-comparison-zone-loads-proposed-building-and-reference-building#S48C2","x":"(1) The zone load is the sensible heating or cooling effect required to maintain the temperature in each zone within the range specified in S34C3(8).\n(2) The loads for each zone in the proposed building and the reference building must be calculated in accordance with the modelling parameters of Specification 34.\n(3) A zone of the proposed building is assessable under J1V3(1)(b)(iii) to (v) if it has—\na 98th percentile heating load of at least 10 W/m2: or\na 98th percentile cooling load of at least 40 W/m2.","g":"/ncc/s48c2"},{"c":"J1O1","t":"Objective","p":"Part J1 Energy efficiency performance requirements","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j1-energy-efficiency-performance-requirements#J1O1","x":"The Objective of this Section is to—\nreduce energy consumption and energy peak demand; and\nreduce greenhouse gas emissions; and\nimprove occupant health and amenity.","g":"/ncc/j1o1","a19":["JO1"]},{"c":"J1F1","t":"Energy efficiency","p":"Part J1 Energy efficiency performance requirements","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j1-energy-efficiency-performance-requirements#J1F1","x":"A building must—\nreduce the energy consumption and energy peak demand of key energy using equipment; and\nreduce the greenhouse gas emissions that occur as a result of a building’s energy consumption and energy source; and\nfor a Class 4 part of a building, improve occupant health and amenity by mitigating the impact of extreme hot and cold weather events and energy blackouts; and\nfor other than in a Class 4 part of a building, protect occupant health and amenity by ensuring the building envelope assists in the maintenance of acceptable internal conditions while the building is occupied; and\nbe able to accommodate the installation of distributed energy resources.","g":"/ncc/j1f1","a19":["JF1"]},{"c":"J1P1","t":"Operational energy use and greenhouse gas emissions","p":"Part J1 Energy efficiency performance requirements","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j1-energy-efficiency-performance-requirements#J1P1","x":"A building, other than a Class 4 part of a building, including its services, must have features that—\nfacilitate the efficient use of energy and near zero operational greenhouse gas emissions appropriate to—\nthe function and use of the building; and\nthe level of human comfort required for the building use; and\nfor the conditioned space, achieve an hourly regulated energy consumption and associated greenhouse gas emission, averaged over the annual hours of operation, of not more than—\nfor a Class 6 building, 40 kJ/m².hr and 4 g of CO2-e/m2.hr; and\nfor a Class 5, 7b, 8 or 9a building other than a ward area, or a Class 9b school, 22 kJ/m².hr and 2.2 g of CO2-e/m2.hr; and\nfor all other building classifications, 8 kJ/m².hr and 1 g of CO2-e/m2.hr.","g":"/ncc/j1p1","a19":["JP1"]},{"c":"J1P2","t":"Thermal performance of a Class 4 part of a building","p":"Part J1 Energy efficiency performance requirements","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j1-energy-efficiency-performance-requirements#J1P2","x":"(1) The total heating load of the habitable rooms and conditioned spaces in a Class 4 part of a building must not exceed the heating load limit in Specification 44.\n(2) The total cooling load of the habitable rooms and conditioned spaces in a Class 4 part of a building must not exceed the cooling load limit in Specification 44.\n(3) The total thermal energy load of the habitable rooms and conditioned spaces in a Class 4 part of a building must not exceed the thermal energy load limit in Specification 44.","g":"/ncc/j1p2"},{"c":"J1P3","t":"Energy usage of a Class 4 part of a building","p":"Part J1 Energy efficiency performance requirements","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j1-energy-efficiency-performance-requirements#J1P3","x":"(1) The energy value of the domestic services of a Class 4 part of a building must not exceed the energy value with—\na 3-star ducted heat pump, rated under the 2019 GEMS determination, heating all spaces that are provided with heating; and\na 3-star ducted heat pump, rated under the 2019 GEMS determination, cooling all spaces that are provided with cooling; and\na 5-star instantaneous gas water heater, rated under the 2017 GEMS determination, providing all domestic hot water; and\na lighting power density of 4 W/m2 serving all internal spaces that are provided with artificial lighting.\n(2) Domestic services, including any associated distribution system and components must, to the degree necessary, have features that facilitate the efficient use of energy appropriate to—\nthe domestic service and its usage; and\nthe geographic location of the building; and\nthe location of the domestic service; and\nthe energy source.","g":"/ncc/j1p3"},{"c":"J1P4","t":"Renewable energy, energy storage and electric vehicle charging","p":"Part J1 Energy efficiency performance requirements","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j1-energy-efficiency-performance-requirements#J1P4","x":"A building must have features that facilitate the future installation of on-site renewable energy generation and energy storage equipment, except where this is already installed to the maximum practicable extent, and electric vehicle charging equipment.","g":"/ncc/j1p4"},{"c":"J1V1","t":"NABERS Energy","p":"Part J1 Energy efficiency performance requirements","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j1-energy-efficiency-performance-requirements#J1V1","x":"(1) For a Class 5 building, compliance with J1P1 is verified when—\na minimum 6-star NABERS Energy for Offices base building Commitment Agreement is obtained; and\nthe energy model required for (a) demonstrates that the base building’s regulated energy greenhouse gas emissions are equivalent to at least 6.6-star when excluding—\ntenant supplementary heating and cooling systems; and\nexternal lighting; and\ncarpark services; and\nthe energy model required for (a) demonstrates either—\na thermal comfort level of between a Predicted Mean Vote of -1 to +1 is achieved across not less than 95% of the floor area of all occupied zones for not less than 98% of the annual hours of operation of the building; or\na dry bulb room temperature is maintained across not less than 95% of the floor area of all occupied zones, other than any room containing an indoor swimming pool, for not less than 95% of the annual hours of operation between—\n18°C and 25°C for conditioned spaces with transitory occupancy; and\n21°C and 24°C for all other conditioned spaces; and\nthe building complies with the additional requirements in Specification 33.\n(2) For a Class 3 building, compliance with J1P1 is verified when—\na minimum 4-star NABERS Energy for Hotels Commitment Agreement is obtained; and\nthe operating hours of the services are not less than 12 hours per day in bedrooms, dining rooms and conference facilities, 24 hours per day in corridors and foyers and 18 hours per day in back-of-house areas; and\nthe energy model required for (a) demonstrates that—\nthe regulated energy greenhouse gas emissions are equivalent to at least 5.3-stars; and\na dry bulb room temperature is maintained across not less than 95% of the floor area of all occupied zones, other than any room containing an indoor swimming pool, for not less than 95% of the annual hours of operation between—\n18°C and 25°C for conditioned spaces with transitory occupancy and food preparation areas; and\n21°C and 24°C for all other conditioned spaces; and\nthe space temperature in any indoor swimming pool chamber is maintained at 2°C above the pool temperature during occupied hours of not less than 12 hours per day; and\nthe building complies with the additional requirements in Specification 33.\n(3) For a Class 6 shopping centre, compliance with J1P1 is verified when—\na minimum 6-stars NABERS Energy for Shopping Centres Commitment Agreement is obtained; and\nthe building has:\nan air-conditioned common area of not less than 20% of the gross lettable area; and\na gross lettable area greater than 15 000 m2; and\nthe energy model required for (a) demonstrates—\nthe regulated energy greenhouse gas emissions of the services covered within the scope of NABERS Energy for Shopping Centres ratings are equivalent to at least 6.7-stars when—\nexcluding carpark services and carpark numbers from NABERS Energy calculation; and\ncalculating solar photovoltaic export based on the reduced site energy use arising from (A); and\na dry bulb room temperature is maintained across not less than 95% of the floor area of all occupied zones, other than any room containing an indoor swimming pool, for not less than 95% of the annual hours of operation between—\n18°C and 25°C for conditioned spaces with transitory occupancy and food preparation areas; and\n21°C and 24°C for all other conditioned spaces; and\nthe building complies with the additional requirements in Specification 33.\n(4) The calculation method for (1), (2), and (3) must comply with ANSI/ASHRAE Standard 140.","g":"/ncc/j1v1","a19":["JV1"]},{"c":"J1V2","t":"Green Star","p":"Part J1 Energy efficiency performance requirements","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j1-energy-efficiency-performance-requirements#J1V2","x":"(1) For a Class 3, 5, 6, 7, 8 or 9 building, compliance with J1P1 is verified when—\nthe building complies with the simulation requirements, and is registered, for a Green Star Buildings rating; and\nthe annual greenhouse gas emissions of the proposed building are less than 90% of the annual greenhouse gas emissions of the reference building; and\nin the proposed building, a thermal comfort level of between a Predicted Mean Vote of -1 to +1 is achieved across not less than 95% of the floor area of all occupied zones for not less than 98% of the annual hours of operation of the building; and\nthe building complies with the additional requirements in Specification 33.\n(2) The calculation method used for (1) must comply with ANSI/ASHRAE Standard 140.","g":"/ncc/j1v2","a19":["JV2"]},{"c":"J1V3","t":"Verification using a reference building","p":"Part J1 Energy efficiency performance requirements","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j1-energy-efficiency-performance-requirements#J1V3","x":"(1) For a Class 3, 5, 6, 7, 8 or 9 building, compliance with J1P1 is verified when—\nit is determined that—\nthe annual greenhouse gas emissions of the proposed building are not more than 97% of the annual greenhouse gas emissions of a reference building when the proposed building is modelled with the proposed services; and\nthe annual greenhouse gas emissions of the services of the proposed building are not more than the annual greenhouse gas emissions of the services of the reference building when the proposed building is modelled with the same services as the reference building; and\nin the proposed building—\nif a Class 5 building, a thermal comfort level of between a Predicted Mean Vote of -1 to +1 is achieved across not less than 95% of the floor area of all occupied zones for not less than 98% of the annual hours of operation of the building; or\na dry bulb room temperature is maintained across not less than 95% of the floor area of all occupied zones, other than any room containing an indoor swimming pool, for not less than 95% of the annual hours of operation between—\n18°C and 25°C for conditioned spaces with transitory occupancy; and\n21°C and 24°C for all other conditioned spaces; or\nin climate zone 1, the 98th percentile zone cooling load across the hours of operation does not exceed 110% of the 98th percentile load in the corresponding zone of the reference building, across 95% of the assessable floor area; or\nin climate zone 8, the 98th percentile zone heating load across the hours of operation does not exceed 110% of the 98th percentile load in the corresponding zone of the reference building, across 95% of the assessable floor area; or\nin climate zones 2 to 7—\nthe 98th percentile zone cooling load across the annual hours of operation does not exceed 120% of the 98th percentile load of the corresponding zone of the reference building, across 95% of the assessable floor area; and\nthe 98th percentile zone heating load across the annual hours of operation does not exceed 120% of the 98th percentile load of the corresponding zone of the reference building, across 95% of the assessable floor area; and\nthe building complies with the additional requirements in Specification 33.\n(2) The calculation method used for (1) must comply with—\nANSI/ASHRAE Standard 140; and\nSpecification 34; and\nSpecification 48.","g":"/ncc/j1v3","a19":["JV3"]},{"c":"J1V4","t":"Verification of building envelope sealing","p":"Part J1 Energy efficiency performance requirements","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j1-energy-efficiency-performance-requirements#J1V4","x":"(1) Compliance with J1P1(a) and J1P2 is verified for building envelope sealing when the envelope is sealed at an air permeability rate, tested in accordance with Method 1 of AS/NZS ISO 9972, of not more than—\nfor a Class 4 part of a building, 10 m³/hr.m² at 50 Pa reference pressure; or\nfor a Class 5, 6, 8, 9a or 9b building, other than a ward area, in climate zones 1, 7 and 8, 5 m³/hr.m² at 50 Pa reference pressure; or\nfor a Class 3 or 9c building, or a Class 9a ward area in climate zones 1, 3, 4, 6, 7 and 8, 5 m³/hr.m² at 50 Pa reference pressure.\n(2) In a Class 4 part of a building, where an air permeability rate of not more than 5 m3/hr.m2 at 50 Pa reference pressure is achieved—\na mechanical ventilation system must be provided that—\ncan be manually overridden; and\nprovides outdoor air, either—\ncontinuously; or\nintermittently, where the system has controls that enable operation for not less than 25% of each 4 hour segment; and\nprovides a flow rate not less than that achieved with the following formula: [formula] , where—\n[formula] = the required air flow rate (L/s); and\n[formula] = the total area of the Class 4 part of a building (m2); and\n[formula] = the number of bedrooms in the Class 4 part of a building; and\n[formula] = the fraction of time within each 4 hour segment that the system is operational; and\nany space with a solid-fuel burning combustion appliance must be ventilated with permanent openings directly to outside with a free area of not less than half of the cross-sectional area of the appliance’s flue; and\nany space with a gas-fueled combustion appliance must be ventilated in accordance with—\nclause 6.4 of AS/NZS 5601.1; and\nclause 6.4.5 of AS/NZS 5601.1.\n(3) For the purposes of (2)(c), the volume of the space is considered to be 1 m3 for determining ventilation requirements.","g":"/ncc/j1v4","a19":["JV4"]},{"c":"J2D1","t":"Deemed-to-Satisfy Provisions","p":"Part J2 Energy efficiency","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j2-energy-efficiency#J2D1","x":"(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements J1P1 to J1P4 are satisfied by complying with—\nJ2D2; and\nJ3D2 to J3D15; and\nJ4D2 to J4D7; and\nJ5D2 to J5D8; and\nJ6D2 to J6D13; and\nJ7D2 to J7D9; and\nJ8D2 to J8D5; and\nJ9D2 to J9D5.\n(2) Where a Performance Solution is proposed, the relevant Performance Requirements must be determined in accordance with A2G2(3) and A2G4(3) as applicable.","g":"/ncc/j2d1","a19":["J0.0"]},{"c":"J2D2","t":"Application of Section J","p":"Part J2 Energy efficiency","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j2-energy-efficiency#J2D2","x":"(1) For a Class 3 to 9 building, other than a Class 4 part of a building, Performance Requirement J1P1 is satisfied by complying with—\nPart J4, for the building fabric; and\nPart J5, for building sealing; and\nPart J6, for air-conditioning and ventilation; and\nPart J7, for artificial lighting and power; and\nPart J8, for heated water supply and swimming pool and spa pool plant; and\nJ9D3, for facilities for energy monitoring; and\nJ9D5(2) to (4), for onsite renewable energy systems.\n(2) For a Class 4 part of a building, Performance Requirement J1P2 is satisfied by complying with—\nJ3D3, using house energy rating software; or\nthe following—\nJ3D4, for ceiling fans; and\nJ3D5, J4D3(1) to (4), and Part J5, for general thermal construction; and\nJ3D7, for roofs; and\nJ3D8 and J3D11 to J3D13, or J3D9, for walls and glazing; and\nJ3D10, for floors.\n(3) For a Class 4 part of a building, Performance Requirement J1P3 is satisfied by complying with—\nfor the net equivalent energy usage—\nJ3D14, for a Class 4 part of a building with a total floor area not greater than 500 m2; or\nJ3D15, using house energy rating software; and\nPart J6, for air-conditioning and ventilation; and\nPart J7, for artificial lighting and power.\n(4) For a Class 3 to 9 building, Performance Requirement J1P4 is satisfied by complying with J9D4(1), J9D4(2) and J9D5(1).","g":"/ncc/j2d2","a19":["J0.1"]},{"c":"J3D1","t":"Deemed-to-Satisfy Provisions","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#J3D1","x":"(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements J1P1 to J1P4 are satisfied by complying with—\nJ2D2; and\nJ3D2 to J3D15; and\nJ4D2 to J4D7; and\nJ5D2 to J5D8; and\nJ6D2 to J6D13; and\nJ7D2 to J7D9; and\nJ8D2 to J8D5; and\nJ9D2 to J9D5.\n(2) Where a Performance Solution is proposed, the relevant Performance Requirements must be determined in accordance with A2G2(3) and A2G4(3) as applicable.","g":"/ncc/j3d1"},{"c":"J3D2","t":"Application of Part","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#J3D2","x":"The Deemed-to-Satisfy Provisions of this Part apply to building elements forming the external building fabric and domestic services of a Class 4 part of a building.","g":"/ncc/j3d2"},{"c":"J3D3","t":"Reducing heating and cooling loads of a Class 4 part of a building using house energy rating software","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#J3D3","x":"(1) The Class 4 part of a building must—\nfor reducing the heating or cooling loads—\ncollectively achieve an average energy rating of not less than 7 stars, including the separate heating and cooling load limits; and\nindividually achieve an energy rating of not less than 6 stars, including the separate heating and cooling load limits; and\nfor thermal breaks, comply with J3D5; and\nfor compensating for a loss of ceiling insulation, other than where the house energy rating software has compensated for a loss of ceiling insulation, comply with Table J3D7w; and\nfor general thermal construction, comply with J4D3(1) to J4D3(4); and\nfor floor edge insulation, comply with J3D10(3), J3D10(5) and J3D10(6); and\nfor building sealing, comply with Part J5.\n(2) Energy ratings referred to in (1)(a)(i) and (ii) must be achieved using—\nhouse energy rating software; and\nthe load limits specified in the ABCB Standard for NatHERS Heating and Cooling Load Limits.","g":"/ncc/j3d3","a19":["J0.2"]},{"c":"Table J3D4","t":"Minimum ceiling fan requirements in climate zones 1, 2, 3 and 5","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_5b4fdbfa-69b0-4c8a-87a1-7158a563e03c","x":"Size of room (m2) | Minimum number and diameter (mm) of ceiling fans required for a bedroom in climate zones 1, 2 and 3 | Minimum number and diameter (mm) of ceiling fans required in a habitable room other than a bedroom in climate zones 1, 2, 3 and 5 (NSW and Qld)\n< 15 | 1 x 900 | 1 x 900\n≥ 15 to < 20 | 1 x 1200 | 1 x 1200\n≥ 20 to < 25 | 1 x 1200 | 1 x 1400\n≥ 25 to < 30 | 1 x 1400 | 2 x 1200\n≥ 30 to < 45 | 1 x 1400 | 2 x 1400\n≥ 45 to < 50 | 2 x 1400 | 3 x 1200\n≥ 50 | 2 x 1400 | 3 x 1400","tb":"J3D4","g":"/ncc/table-j3d4"},{"c":"J3D4","t":"Ceiling fans in a Class 4 part of a building","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#J3D4","x":"(1) Ceiling fans must be installed in accordance with Table J3D4 in—\nclimate zones 1, 2 and 3; and\nclimate zone 5 in New South Wales and Queensland.\n(2) Ceiling fans required by (1) must—\nbe permanently installed; and\nhave a speed controller.\nTable J3D4 Minimum ceiling fan requirements in climate zones 1, 2, 3 and 5\nSize of room (m2)\nMinimum number and diameter (mm) of ceiling fans required for a bedroom in climate zones 1, 2 and 3\nMinimum number and diameter (mm) of ceiling fans required in a habitable room other than a bedroom in climate zones 1, 2, 3 and 5 (NSW and Qld)\n< 15\n1 x 900\n1 x 900\n≥ 15 to < 20\n1 x 1200\n1 x 1200\n≥ 20 to < 25\n1 x 1200\n1 x 1400\n≥ 25 to < 30\n1 x 1400\n2 x 1200\n≥ 30 to < 45\n1 x 1400\n2 x 1400\n≥ 45 to < 50\n2 x 1400\n3 x 1200\n≥ 50\n2 x 1400\n3 x 1400","g":"/ncc/j3d4","a19":["J0.3"]},{"c":"J3D5","t":"Roof thermal breaks of a Class 4 part of a building","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#J3D5","x":"(1) A metal-framed flat, skillion or cathedral roof that—\nhas metal sheet roofing directly fixed to metal purlins, metal rafters, metal battens or the like; and\ndoes not have a ceiling lining or has a ceiling lining fixed directly to the metal purlins, metal rafters, metal battens or the like; and\nhas not achieved the required Total R-Value specified in Table J3D7t, calculated using a method that accounts for the effects of thermal bridging,\nmust have a thermal break, consisting of a material with an R-Value of greater than or equal to R0.2, installed within the structure.\n(2) The requirements of (1) do not apply to roofs constructed using insulated sandwich panels.","g":"/ncc/j3d5","a19":["J0.4"]},{"c":"J3D6","t":"* * * * *","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#J3D6","x":"This clause has deliberately been left blank.","g":"/ncc/j3d6","a19":["J0.5"]},{"c":"Table J3D7a","t":"Flat concrete roof — minimum R-Value for ceiling insulation: climate zone 1","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_193b9818-e743-40b1-b622-966347f0f340","x":"Reflective insulation under-roof | SA ≤ 0.23 | SA > 0.23 to ≤ 0.32 | SA > 0.32 to ≤ 0.42 | SA > 0.42 to ≤ 0.53 | SA > 0.53 to ≤ 0.64\nYes | 1.0 | 1.5 | 2.0 | 2.5 | 3.0\nNo | 1.5 | 2.0 | 2.5 | 3.0 | 4.0\nTable Notes\nSA = solar absorptance.\nThe R-Value of reflective insulation is not to be included in the R-Value of any under-roof or ceiling insulation.\nR-Values listed are for the labelled, declared R-Value of insulation.","tb":"J3D7","g":"/ncc/table-j3d7a"},{"c":"Table J3D7b","t":"Timber-framed pitched roof with horizontal ceiling — minimum R-Value for ceiling insulation: climate zone 1","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_5d63432b-6cdf-4052-bd1f-f685b168963f","x":"Roof ventilation | Reflective insulation under-roof | Under-roof insulation R-Value | SA ≤ 0.23 | SA > 0.23 to ≤ 0.32 | SA > 0.32 to ≤ 0.42 | SA > 0.42 to ≤ 0.53 | SA > 0.53 to ≤ 0.64\nVented | Yes | < 1.0 | 1.5 | 1.5 | 1.5 | 1.5 | 2.0\n≥ 1.0 to < 1.5 | 1.5 | 1.5 | 1.5 | 1.5 | 1.5\n≥ 1.5 to < 2.0 | 1.5 | 1.5 | 1.5 | 1.5 | 1.5\n≥ 2.0 | 1.5 | 1.5 | 1.5 | 2.0 | 2.0\nNo | < 1.0 | 2.0 | 2.5 | 4.0 | 5.0 | X\n≥ 1.0 to < 1.5 | 1.5 | 1.5 | 1.5 | 1.5 | 2.5\n≥ 1.5 to < 2.0 | 1.5 | 1.5 | 1.5 | 2.0 | 2.0\n≥ 2.0 | 1.5 | 1.5 | 1.5 | 1.5 | 1.5\nStandard | Yes | < 1.0 | 1.5 | 1.5 | 2.0 | 3.0 | 4.0\n≥ 1.0 to < 1.5 | 1.5 | 1.5 | 1.5 | 1.5 | 2.5\n≥ 1.5 to < 2.0 | 1.5 | 1.5 | 1.5 | 1.5 | 2.0\n≥ 2.0 | 1.5 | 1.5 | 1.5 | 1.5 | 1.5\nNo | < 1.0 | 2.5 | 4.0 | 6.0 | X | X\n≥ 1.0 to < 1.5 | 1.5 | 1.5 | 1.5 | 1.5 | 4.0\n≥ 1.5 to < 2.0 | 1.5 | 1.5 | 2.0 | 2.0 | 2.5\n≥ 2.0 | 1.5 | 1.5 | 1.5 | 2.0 | 2.5\nTable Notes\nSA = solar absorptance.\nA roof space is to be considered ‘vented’ if it—\nhas one wind-driven roof ventilator per 50 m2 of ceiling area with gable, eave or ridge vents; or\nhas one powered roof ventilator per 200 m2 of ceiling area with gable, eave or ridge vents; or\nis a tiled roof without sarking-type material at roof level.\nIf a roof is not ‘vented’, it is a ‘standard’ roof.\nThe R-Value of reflective insulation is not to be included in the R-Value of any under-roof or ceiling insulation.\nR-Values listed are for the labelled, declared R-Value of insulation.\nX = not permitted.","tb":"J3D7","g":"/ncc/table-j3d7b"},{"c":"Table J3D7c","t":"Timber-framed flat, skillion or cathedral roof — minimum R-Value for ceiling insulation: climate zone 1","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_326aacb3-2d3b-494d-8600-8446040c8e5d","x":"Reflective insulation under-roof | SA ≤ 0.23 | SA > 0.23 to ≤ 0.32 | SA > 0.32 to ≤ 0.42 | SA > 0.42 to ≤ 0.53 | SA > 0.53 to ≤ 0.64\nYes | 1.5 | 1.5 | 2.0 | 3.0 | 4.0\nNo | 1.5 | 3.5 | 5.0 | X | X\nTable Notes\nSA = solar absorptance.\nThe R-Value can be achieved by installing insulation under the roof or on top of the ceiling or a combination of both.\nThe R-Value of reflective insulation is not to be included in the R-Value of any under-roof or ceiling insulation.\nR-Values listed are for the labelled, declared R-Value of insulation.\nX = not permitted.","tb":"J3D7","g":"/ncc/table-j3d7c"},{"c":"Table J3D7d","t":"Flat concrete roof — minimum R-Value for ceiling insulation: climate zone 2","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_a6a4c83b-0da0-49d6-8986-b682c3622cfd","x":"Reflective insulation under-roof | SA ≤ 0.23 | SA > 0.23 to ≤ 0.32 | SA > 0.32 to ≤ 0.42 | SA > 0.42 to ≤ 0.53 | SA > 0.53 to ≤ 0.64\nYes | 2.0 | 2.5 | 2.5 | 3.0 | 3.5\nNo | 3.0 | 3.0 | 3.5 | 4.0 | 4.5\nTable Notes\nSA = solar absorptance.\nThe R-Value of reflective insulation is not to be included in the R-Value of any under-roof or ceiling insulation.\nR-Values listed are for the labelled, declared R-Value of insulation.","tb":"J3D7","g":"/ncc/table-j3d7d"},{"c":"Table J3D7e","t":"Timber-framed pitched roof with horizontal ceiling — minimum R-Value for ceiling insulation: climate zone 2","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_4ec953c1-5c59-4e53-ad25-7ac38467102b","x":"Roof ventilation | Reflective insulation under-roof | Under-roof insulation R-Value | SA ≤ 0.23 | SA > 0.23 to ≤ 0.32 | SA > 0.32 to ≤ 0.42 | SA > 0.42 to ≤ 0.53 | SA > 0.53 to ≤ 0.64\nVented | Yes | Any | 2.5\nNo | 0 to < 0.5 | 2.5 | 3.0 | 3.0 | 3.5 | 3.5\n≥ 0.5 | 2.5\nStandard | Yes | Any | 2.5\nNo | 0 to < 0.5 | 3.0 | 3.0 | 3.5 | 4.0 | 4.0\n≥ 0.5 to < 1.0 | 2.5 | 2.5 | 2.5 | 3.0 | 3.0\n≥ 1.0 | 2.5\nTable Notes\nSA = solar absorptance.\nA roof is considered ‘vented’ if it—\nhas one wind-driven roof ventilator per 50 m2 of ceiling area with gable, eave or ridge vents; or\nhas one powered roof ventilator per 200 m2 of ceiling area with gable, eave or ridge vents; or\nis a tiled roof without sarking-type material at roof level.\nIf a roof is not ‘vented’, it is a ‘standard’ roof.\nThe R-Value of reflective insulation is not to be included in the R-Value of any under-roof or ceiling insulation.\nR-Values listed are for the labelled, declared R-Value of insulation.","tb":"J3D7","g":"/ncc/table-j3d7e"},{"c":"Table J3D7f","t":"Timber-framed flat, skillion or cathedral roof — minimum R-Value for ceiling insulation: climate zone 2","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_64f563df-4e58-4419-9f2e-1db60bbc25fe","x":"Reflective insulation under-roof | SA ≤ 0.23 | SA > 0.23 to ≤ 0.32 | SA > 0.32 to ≤ 0.42 | SA > 0.42 to ≤ 0.53 | SA > 0.53 to ≤ 0.64\nYes | 2.5 | 2.5 | 2.5 | 2.5 | 2.5\nNo | 3.0 | 3.0 | 3.5 | 4.0 | 4.0\nTable Notes\nSA = solar absorptance.\nThe R-Value can be achieved by installing insulation under the roof or on top of the ceiling or a combination of both.\nThe R-Value of reflective insulation is not to be included in the R-Value of any under-roof or ceiling insulation.\nR-Values listed are for the labelled, declared R-Value of insulation.","tb":"J3D7","g":"/ncc/table-j3d7f"},{"c":"Table J3D7g","t":"Flat concrete roof — minimum R-Value for ceiling insulation: climate zone 3","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_d190d215-91d8-44e5-8c4b-7ee0b1c913db","x":"Reflective insulation under-roof | SA ≤ 0.23 | SA > 0.23 to ≤ 0.32 | SA > 0.32 to ≤ 0.42 | SA > 0.42 to ≤ 0.53 | SA > 0.53 to ≤ 0.64\nYes | 2.0 | 2.0 | 2.5 | 2.5 | 3.0\nNo | 3.0 | 3.5 | 4.0 | 4.5 | 5.0\nTable Notes\nSA = solar absorptance.\nThe R-Value of reflective insulation is not to be included in the R-Value of any under-roof or ceiling insulation.\nR-Values listed are for the labelled, declared R-Value of insulation.","tb":"J3D7","g":"/ncc/table-j3d7g"},{"c":"Table J3D7h","t":"Timber-framed pitched roof with horizontal ceiling — minimum R-Values for ceiling insulation: climate zone 3","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_cca4dec5-da74-4276-af12-3d4ceb065e2d","x":"Roof ventilation | Reflective insulation under-roof | Under-roof insulation R-Value | SA ≤ 0.23 | SA > 0.23 to ≤ 0.32 | SA > 0.32 to ≤ 0.42 | SA > 0.42 to ≤ 0.53 | SA > 0.53 to ≤ 0.64\nVented | Yes | < 0.5 | 2.5 | 2.5 | 2.5 | 2.5 | 2.5\n≥ 0.5 to < 1.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0\n≥ 1.0 to < 1.5 | 2.5 | 2.0 | 2.0 | 2.0 | 2.0\n≥ 1.5 to < 2.0 | 2.0 | 2.0 | 2.5 | 2.5 | 2.5\n≥ 2.0 | 2.5 | 2.5 | 3.0 | 3.0 | 3.0\nNo | < 0.5 | 3.5 | 4.0 | 4.5 | 5.0 | X\n≥ 0.5 to < 1.0 | 3.0 | 3.5 | 3.5 | 4.0 | 4.5\n≥ 1.0 to < 1.5 | 2.5 | 3.0 | 3.0 | 3.0 | 3.5\n≥ 1.5 to < 2.0 | 2.5 | 3.0 | 3.0 | 3.0 | 3.0\n≥ 2.0 | 2.5 | 2.5 | 3.0 | 3.0 | 3.0\nStandard | Yes | < 0.5 | 2.0 | 2.0 | 2.5 | 2.5 | 2.5\n≥ 0.5 to < 1.0 | 2.0 | 2.0 | 2.5 | 2.5 | 2.5\n≥ 1.0 to < 1.5 | 2.0 | 2.0 | 2.0 | 2.0 | 2.5\n≥ 1.5 to < 2.0 | 2.0 | 2.5 | 2.5 | 2.5 | 3.0\n≥ 2.0 | 2.0 | 2.0 | 2.5 | 2.5 | 2.5\nNo | < 0.5 | 3.5 | 4.0 | 5.0 | X | X\n≥ 0.5 to < 1.0 | 3.0 | 3.0 | 3.5 | 4.0 | 5.0\n≥ 1.0 to < 1.5 | 2.5 | 2.5 | 3.0 | 3.0 | 3.5\n≥ 1.5 to < 2.0 | 2.0 | 2.0 | 2.5 | 2.5 | 2.5\n≥ 2.0 | 2.0 | 2.0 | 2.5 | 2.5 | 2.5\nTable Notes\nSA = solar absorptance.\nA roof is considered ‘vented’ if it—\nhas one wind-drive roof ventilator per 50 m2 of ceiling area with gable, eave or ridge vents; or\nhas one powered roof ventilator per 200 m2 of ceiling area with gable, eave or ridge vents; or\nis a tiled roof without sarking-type material at roof level.\nIf a roof is not ‘vented’, it is a ‘standard’ roof.\nThe R-Value of reflective insulation is not to be included in the R-Value of any under-roof or ceiling insulation.\nR-Values listed are for the labelled, declared R-Value of insulation.\nX = not permitted.","tb":"J3D7","g":"/ncc/table-j3d7h"},{"c":"Table J3D7i","t":"Timber-framed flat, skillion or cathedral roof — minimum R-Value for ceiling insulation: climate zone 3","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_e929de14-cf70-4d3e-8e84-22379e0ae8f8","x":"Reflective insulation under-roof | SA ≤ 0.23 | SA > 0.23 to ≤ 0.32 | SA > 0.32 to ≤ 0.42 | SA > 0.42 to ≤ 0.53 | SA > 0.53 to ≤ 0.64\nYes | 2.0 | 2.0 | 2.5 | 2.5 | 2.5\nNo | 3.5 | 4.0 | 5.0 | X | X\nTable Notes\nSA = solar absorptance.\nThe R-Value can be achieved by installing insulation under the roof or on top of the ceiling or a combination of both.\nThe R-Value of reflective insulation is not to be included in the R-Value of any under-roof or ceiling insulation.\nR-Values listed are for the labelled, declared R-Value of insulation.\nX = not permitted.","tb":"J3D7","g":"/ncc/table-j3d7i"},{"c":"Table J3D7j","t":"Flat concrete roof — minimum R-Value for ceiling insulation: climate zone 4","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_4a3b991b-7eaa-4307-87ff-dd24f194dd51","x":"Reflective insulation under-roof | ≤ 0.64\nYes | 2.0\nNo | 2.5\nTable Notes\nSA = solar absorptance.\nThe R-Value of reflective insulation is not to be included in the R-Value of any under-roof or ceiling insulation.\nR-Values listed are for the labelled, declared R-Value of insulation.","tb":"J3D7","g":"/ncc/table-j3d7j"},{"c":"Table J3D7k","t":"Timber-framed pitched roof with horizontal ceiling — minimum R-Value for ceiling insulation: climate zone 4","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_c94c743d-6fb8-4a6e-b898-2da0baf3644d","x":"Roof ventilation | Reflective insulation under- roof | Under-roof insulation R-Value | SA ≤ 0.23 | SA > 0.23 to ≤ 0.64\nVented | Yes | < 0.5 | 3.0 | 3.5\n≥ 0.5 | 3.0 | 3.0\nNo | Any | 3.5\nStandard | Yes | Any | 3.0\nNo | < 0.5 | 3.5\n≥ 0.5 | 3.0\nTable Notes\nSA = solar absorptance.\nA roof is considered ‘vented’ if it—\nhas one wind-driven roof ventilator per 50 m2 of ceiling area with gable, eave or ridge vents; or\nhas one powered roof ventilator per 200 m2 of ceiling area with gable, eave or ridge vents; or\nis a tiled roof without sarking-type material at roof level.\nIf a roof is not ‘vented’, it is a ‘standard’ roof.\nThe R-Value of reflective insulation is not to be included in the R-Value of any under-roof or ceiling insulation.\nR-Values listed are for the labelled, declared R-Value of insulation.","tb":"J3D7","g":"/ncc/table-j3d7k"},{"c":"Table J3D7l","t":"Timber-framed flat, skillion or cathedral timber roof — minimum R-Value for ceiling insulation: climate zone 4","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_5757b994-46a0-456c-85e6-bba1ebf8391e","x":"Reflective insulation under-roof | SA ≤ 0.64\nYes | 3.0\nNo | 3.5\nTable Notes\nSA = solar absorptance.\nThe R-Value can be achieved by installing insulation under the roof or on top of the ceiling or a combination of both.\nThe R-Value of reflective insulation is not to be included in the R-Value of any under-roof or ceiling insulation.\nR-Values listed are for the labelled, declared R-Value of insulation.","tb":"J3D7","g":"/ncc/table-j3d7l"},{"c":"Table J3D7m","t":"Flat concrete roof — minimum R-Value for ceiling insulation: climate zone 5","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_deada076-ebc0-4652-a29e-35cda3b46182","x":"Reflective insulation under-roof | SA ≤ 0.42 | SA > 0.42 to ≤ 0.64\nYes | 3.0 | 3.5\nNo | 4.0 | 4.0\nTable Notes\nSA = solar absorptance.\nThe R-Value of reflective insulation is not to be included in the R-Value of any under-roof or ceiling insulation.\nR-Values listed are for the labelled, declared R-Value of insulation.","tb":"J3D7","g":"/ncc/table-j3d7m"},{"c":"Table J3D7n","t":"Timber-framed pitched roof with horizontal ceiling — minimum R-Value for ceiling insulation: climate zone 5","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_49c46bc9-88a8-4075-8c9b-7b4b985791d8","x":"Roof ventilation | Reflective insulation under- roof | Under-roof insulation R-Value | SA ≤ 0.42 | SA > 0.42 to ≤ 0.64\nVented | Yes | < 0.5 | 3.0 | 2.5\n≥ 0.5 | 2.5\nNo | 0 to < 2.0 | 3.0\n≥ 2.0 | 2.5\nStandard | Yes | Any | 2.5\nNo | 0 to < 1.0 | 3.0\n≥ 1.0 to < 2.0 | 2.5\n≥ 2.0 | 3.0\nTable Notes\nSA = solar absorptance.\nA roof is considered ‘vented’ if it—\nhas one wind-driven roof ventilator per 50 m2 of ceiling area with gable, eave or ridge vents; or\nhas one powered roof ventilator per 200 m2 of ceiling area with gable, eave or ridge vents; or\nis a tiled roof without sarking-type material at roof level.\nIf a roof is not ‘vented’, it is a ‘standard’ roof.\nThe R-Value of reflective insulation is not to be included in the R-Value of any under-roof or ceiling insulation.\nR-Values listed are for the labelled, declared R-Value of insulation.","tb":"J3D7","g":"/ncc/table-j3d7n"},{"c":"Table J3D7o","t":"Timber-framed flat, skillion or cathedral roof — minimum R-Value for ceiling insulation: climate zone 5","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_bf266037-5a29-4c2d-9858-1403ac8df5c7","x":"Reflective insulation under- roof | R-Value\nYes | 2.5\nNo | 3.0\nTable Notes\nThe R-Value can be achieved by installing insulation under the roof or on top of the ceiling or a combination of both.\nThe R-Value of reflective insulation is not to be included in the R-Value of any under-roof or ceiling insulation.\nR-Values listed are for the labelled, declared R-Value of insulation.","tb":"J3D7","g":"/ncc/table-j3d7o"},{"c":"Table J3D7p","t":"Flat concrete roof — minimum R-Value for ceiling insulation: climate zones 7 and 8","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_4772e33e-f83d-4f00-a2ef-1f8a4bae48b7","x":"Reflective insulation under-roof | SA ≤ 0.23 | SA > 0.23 to ≤ 0.32 | SA > 0.32 to ≤ 0.42 | SA > 0.42 to ≤ 0.53 | SA > 0.53 to ≤ 0.64 | SA > 0.64 to ≤ 0.73 | SA > 0.73\nYes | 3.5 | 3.5 | 3.5 | 3.0 | 3.0 | 3.0 | 2.5\nNo | 4.0 | 3.0 | 3.0 | 2.5 | 2.5 | 2.5 | 2.0\nTable Notes\nSA = solar absorptance.\nThe R-Value of reflective insulation is not to be included in the R-Value of any under-roof or ceiling insulation.\nR-Values listed are for the labelled, declared R-Value of insulation.","tb":"J3D7","g":"/ncc/table-j3d7p"},{"c":"Table J3D7q","t":"Timber-framed pitched roof with flat ceiling — minimum R-Value for ceiling insulation: climate zones 7 and 8","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_8e636821-4d94-491f-8a30-7a82597c1e58","x":"Roof ventilation | Reflective insulation under-roof | Under-roof insulation R-Value | SA ≤ 0.23 | SA > 0.23 to ≤ 0.32 | SA > 0.32 to ≤ 0.42 | SA > 0.42 to ≤ 0.53 | SA > 0.53 to ≤ 0.64 | SA > 0.64 to ≤ 0.73 | SA > 0.73 to ≤ 0.85 | SA > 0.85\nStandard | Yes | 0 to < 1.0 | 4.5 | 4.5 | 4.5 | 4.0 | 4.0 | 4.0 | 4.0 | 4.0\n≥ 1.0 | 4.0 | 4.0 | 4.0 | 4.0 | 4.0 | 4.0 | 4.0 | 4.0\nNo | 0 to < 1.0 | 5.0 | 4.5 | 4.5 | 4.0 | 4.0 | 3.5 | 3.5 | 3.5\n≥ 1.0 to < 1.5 | 4.5 | 4.5 | 4.0 | 4.0 | 4.0 | 4.0 | 3.5 | 3.5\n≥ 1.5 | 4.0 | 4.0 | 4.0 | 4.0 | 4.0 | 4.0 | 4.0 | 4.0\nVented | Yes | 0 to < 1.0 | 4.5 | 4.5 | 4.5 | 4.5 | 4.5 | 4.0 | 4.0 | 4.0\n≥ 1.0 | 4.5 | 4.5 | 4.5 | 4.5 | 4.0 | 4.0 | 4.0 | 4.0\nNo | 0 to < 1.0 | 5.0 | 4.5 | 4.5 | 4.5 | 4.0 | 4.0 | 3.5 | 3.5\n≥ 1.0 to < 1.5 | 4.5 | 4.5 | 4.5 | 4.5 | 4.0 | 4.0 | 4.0 | 4.0\n≥ 1.5 | 4.5 | 4.5 | 4.5 | 4.5 | 4.5 | 4.0 | 4.0 | 4.0\nTable Notes\nSA = solar absorptance.\nA roof is considered ‘vented’ if it—\nhas one wind-driven roof ventilator per 50 m2 of ceiling area with gable, eave or ridge vents; or\nhas one powered roof ventilator per 200 m2 of ceiling area with gable, eave or ridge vents; or\nis ventilated to outdoor air through evenly distributed openings in accordance with Table F8D5; or\nis a tiled roof without sarking-type material at roof level.\nIf a roof is not ‘vented’, it is a ‘standard’ roof.\nThe R-Value of reflective insulation is not to be included in the R-Value of any under-roof or ceiling insulation.\nR-Values listed are for the labelled, declared R-Value of insulation.","tb":"J3D7","g":"/ncc/table-j3d7q"},{"c":"Table J3D7r","t":"Timber-framed flat, skillion or cathedral roof — minimum R-Value for ceiling insulation: climate zones 7 and 8","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_9b28c94d-30f5-4bce-978b-6baf04f52036","x":"Reflective insulation under-roof | SA ≤ 0.23 | SA > 0.23 to ≤ 0.32 | SA > 0.32 to ≤ 0.42 | SA > 0.42 to ≤ 0.53 | SA > 0.53 to ≤ 0.64 | SA > 0.64 to ≤ 0.73 | SA > 0.73 to ≤ 0.85 | SA > 0.85\nYes | 4.5 | 4.5 | 4.5 | 4.0 | 4.0 | 4.0 | 4.0 | 4.0\nNo | 5.0 | 4.5 | 4.5 | 4.0 | 4.0 | 3.5 | 3.5 | 3.5\nTable Notes\nSA = solar absorptance.\nThe R-Value can be achieved by installing insulation under the roof or on top of the ceiling or a combination of both.\nThe R-Value of reflective insulation is not to be included in the R-Value of any under-roof or ceiling insulation.\nR-Values listed are for the labelled, declared R-Value for insulation.","tb":"J3D7","g":"/ncc/table-j3d7r"},{"c":"Table J3D7s","t":"Metal-framed pitched roof with horizontal ceiling — minimum Total R-Value of ceiling to account for thermal bridging","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_5bed239d-d208-4a8a-9aa6-7798c64c3eb4","x":"Ceiling insulation R-Value from Tables J3D7a to J3D7r and J3D7(1)(f) as applicable | Minimum Total R-Value to account for thermal bridging\n1.5 | 1.38\n2.0 | 1.74\n2.5 | 2.09\n3.0 | 2.43\n3.5 | 2.63\n4.0 | 2.95\n4.5 | 3.27\n5.0 | 3.59\n5.5 | 3.91\n6.0 | 4.23\nTable Notes\nThe Total R-Value calculation only includes the ceiling frame, insulation and ceiling lining. It is not to include the internal air films, roof space or roof lining.\nMinimum ceiling Total R-Values are in-situ values. They account for compression of insulation.","tb":"J3D7","g":"/ncc/table-j3d7s"},{"c":"Table J3D7t","t":"Metal-framed flat, skillion or cathedral roof — minimum Total R-Value to account for thermal bridging","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_891ecf3d-816f-4cf1-aac4-7aac94e96209","x":"Ceiling insulation R-Value from Tables J3D7a to J3D7r, and J3D7(1)(f) as applicable | Minimum Total R-Value to account for thermal bridging: heat flow down | Minimum Total R-Value to account for thermal bridging: heat flow up\n1.0 | 1.40 | 1.32\n1.5 | 1.86 | 1.78\n2.0 | 2.29 | 2.21\n2.5 | 2.71 | 2.63\n3.0 | 3.11 | 3.02\n3.5 | 3.31 | 3.22\n4.0 | 3.66 | 3.57\n4.5 | 3.98 | 3.90\n5.0 | 4.32 | 4.22\n5.5 | 4.63 | 4.53\n6.0 | 4.93 | 4.82\nTable Notes\nMinimum Total R-Values are in-situ values. They account for compression of insulation.\nDirection of heat flow must be determined in accordance with Table J3D7v.","tb":"J3D7","g":"/ncc/table-j3d7t"},{"c":"Table J3D7u","t":"Metal-framed flat, skillion or cathedral roof – thermal bridging mitigation","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_d078b8bb-6900-4b26-8489-e55875f1be0d","x":"Minimum ceiling R-Value from Tables J3D7a to J3D7r, and J3D7(1)(f) as applicable | Option 1– increase insulation between roof frame members to specified minimum R-Value | Option 2 – add a layer of continuous insulation with specified minimum R-Value above or below the roof frame members\n1.0 | 1.5 | 0.13\n1.5 | 2.5 | 0.30\n2.0 | 3.5 | 0.30\n2.5 | 5.0 | 0.40\n3.0 | 6.0 | 0.60\n3.5 | X | 0.60\n4.0 | X | 0.60\n4.5 | X | 0.60\n5.0 | X | 0.60\n5.5 | X | 0.60\n6.0 | X | 0.60\nTable Notes\nMinimum R-Values are in-situ values. They account for compression of insulation.\nX= not permitted.","tb":"J3D7","g":"/ncc/table-j3d7u"},{"c":"Table J3D7v","t":"Direction of heat flow","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_6eea30e3-9800-452b-8739-77f06eea1cb5","x":"Climate zone | Direction of heat flow\n1 | Down\n2 – altitude less than 300 m | Down\n2 – altitude 300 m or more | Down and up\n3 | Down and up\n4 | Up\n5 | Up\n6 | Up\n7 | Up\n8 | Up","tb":"J3D7","g":"/ncc/table-j3d7v"},{"c":"Table J3D7w","t":"Adjusted minimum R-Value of ceiling insulation required to compensate for loss of ceiling insulation area","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_c80e7a28-ac85-46c2-a6fe-99bfec13d480","x":"Percentage of ceiling area uninsulated | Minimum R-Value of ceiling insulation required to satisfy J3D7(1) and J3D7(3 )\n1.0 | 1.5 | 2.0 | 2.5 | 3.0 | 3.5 | 4.0 | 4.5 | 5.0 | 5.5\n0.5% to less than 1.0% | 1.0 | 1.6 | 2.2 | 2.8 | 3.4 | 4.0 | 4.7 | 5.4 | 6.2 | 6.9\n1.0% to less than 1.5% | 1.1 | 1.7 | 2.3 | 2.9 | 3.6 | 4.4 | 5.2 | 6.1 | 7.0 | X\n1.5% to less than 2.0% | 1.1 | 1.7 | 2.4 | 3.1 | 3.9 | 4.8 | 5.8 | 6.8 | X | X\n2.0% to less than 2.5% | 1.1 | 1.8 | 2.5 | 3.3 | 4.2 | 5.3 | 6.5 | X | X | X\n2.5% to less than 3.0% | 1.2 | 1.9 | 2.6 | 3.6 | 4.6 | 5.9 | X | X | X | X\n3.0% to less than 4.0% | 1.2 | 2.0 | 3.0 | 4.2 | 5.7 | X | X | X | X | X\n4.0% to less than 5.0% | 1.3 | 2.2 | 3.4 | 5.0 | X | X | X | X | X | X\nTable Notes\nInterpolation is allowed for values between those shown.\nX = not permitted.","tb":"J3D7","g":"/ncc/table-j3d7w"},{"c":"Table J3D7x","t":"Total R-Values for roofs constructed with insulated sandwich panels","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_9a7c231a-af03-451f-805a-eb205f64a4fc","x":"Climate zone | SA ≤ 0.23 | SA > 0.23 to ≤ 0.32 | SA > 0.32 to ≤ 0.42 | SA > 0.42 to ≤ 0.53 | SA > 0.53 to ≤ 0.64 | SA > 0.64 to ≤ 0.73 | SA > 0.73 to ≤ 0.85 | SA > 0.85\n1 | 1.86 | 3.31 | 4.32 | X | X | X | X | X\n2 – heat flow down | 3.11 | 3.11 | 3.31 | 3.66 | 3.66 | X | X | X\n2 – heat flow up | 3.02 | 3.02 | 3.22 | 3.57 | 3.57 | X | X | X\n3 – heat flow down | 3.31 | 3.66 | 4.32 | X | X | X | X | X\n3 – heat flow up | 3.22 | 3.57 | 4.22 | X | X | X | X | X\n4 | 3.22 | 3.22 | 3.22 | 3.22 | 3.22 | X | X | X\n5 | 3.02 | 3.02 | 3.02 | 3.02 | 3.02 | X | X | X\n6 | 3.57 | 3.57 | 3.57 | 3.57 | 3.57 | 3.57 | 3.57 | 3.57\n7 | 4.22 | 3.90 | 3.90 | 3.57 | 3.57 | 3.22 | 3.22 | 3.22\n8 | 3.90 | 3.57 | 3.57 | 3.22 | 3.22 | 3.02 | 3.02 | 3.02\nTable Notes\nSA = solar absorptance.\nDirection of heat flow must be determined in accordance with Table J3D7v.\nX = not permitted.","tb":"J3D7","g":"/ncc/table-j3d7x"},{"c":"J3D7","t":"Roofs and ceilings of a Class 4 part of a building","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#J3D7","x":"(1) Roof and ceiling insulation must achieve the minimum R-Value —\nin climate zone 1, in accordance with Tables J3D7a, J3D7b and J3D7c as applicable; and\nin climate zone 2, in accordance with Tables J3D7d, J3D7e and J3D7f as applicable; and\nin climate zone 3, in accordance with Tables J3D7g, J3D7h and J3D7i as applicable; and\nin climate zone 4, in accordance with Tables J3D7j, J3D7k and J3D7l as applicable; and\nin climate zone 5, in accordance with Tables J3D7m, J3D7n and J3D7o as applicable; and\nin climate zone 6—\nR3.5; or\nif the roof contains reflective insulation, R3.0; and\nin climate zones 7 and 8, in accordance with Tables J3D7p, J3D7q and J3D7r as applicable.\n(2) Reflective insulation installed to comply with (1) must—\nhave a surface emittance of not more than 0.05; and\nbe adjacent to a roof space of not less than 20 mm; and\nin climate zones 3 to 8, be downward facing.\n(3) The thermal bridging in a metal-framed roof must be addressed as follows—\nfor a pitched roof with a horizontal ceiling—\nachieving the Total R-Value in Table J3D7s, calculated using a method that accounts for the effects of thermal bridging; or\nincreasing the R-Value of the insulation between the ceiling frames by R0.5 more than the R-Value derived from (1); or\nadding a continuous ceiling insulation layer with a minimum R-Value of R0.13 above or below the ceiling joists or the bottom chords of the trusses; or\nachieving the required ceiling R-Value derived from (1) by stacking two layers of insulation immediately on top of each other, such that the top layer is orientated to cover the ceiling joists or bottom chord of the trusses and has an R-Value of at least R0.5; or\nfor a flat, skillion or cathedral roof—\nachieving the Total R-Value in Table J3D7t, calculated using a method that accounts for the effects of thermal bridging; or\ncomplying with Table J3D7u.\n(4) Where F8D5(1) applies, continuous insulation placed above the primary insulation layer to mitigate thermal bridging must have a vapour permeance of not less than that of the primary insulation layer.\n(5) Where, for operational or safety reasons, the area of ceiling insulation required is reduced, the loss of insulation must be compensated for in accordance with Table J3D7w.\n(6) Where the ceiling insulation required by (1) to (5) has an R-Value —\ngreater than R3.0 and less than or equal to R4.5, it may be reduced to R3.0 within 450 mm of an external wall; or\ngreater than R4.5, it may be reduced to R3.0 within 450 mm of an external wall, provided all other required ceiling insulation is increased by R0.5.\n(7) The requirements of (1) to (6) do not apply to roofs constructed using insulated sandwich panels.\n(8) Roofs constructed using insulated sandwich panels must achieve the minimum Total R-Value in Table J3D7x.\n(9) In climate zones 1 to 5, the solar absorptance of the upper surface of a roof must not be more than 0.64.\nTable J3D7a Flat concrete roof — minimum R-Value for ceiling insulation: climate zone 1\nReflective insulation under-roof\nSA ≤ 0.23\nSA > 0.23 to ≤ 0.32\nSA > 0.32 to ≤ 0.42\nSA > 0.42 to ≤ 0.53\nSA > 0.53 to ≤ 0.64\nYes\n1.0\n1.5\n2.0\n2.5\n3.0\nNo\n1.5\n2.0\n2.5\n3.0\n4.0\nTable Notes\nSA = solar absorptance.\nThe R-Value of reflective insulation is not to be included in the R-Value of any under-roof or ceiling insulation.\nR-Values listed are for the labelled, declared R-Value of insulation.\nTable J3D7b Timber-framed pitched roof with horizontal ceiling — minimum R-Value for ceiling insulation: climate zone 1\nRoof ventilation\nReflective insulation under-roof\nUnder-roof insulation R-Value\nSA ≤ 0.23\nSA > 0.23 to ≤ 0.32\nSA > 0.32 to ≤ 0.42\nSA > 0.42 to ≤ 0.53\nSA > 0.53 to ≤ 0.64\nVented\nYes\n< 1.0\n1.5\n1.5\n1.5\n1.5\n2.0\n≥ 1.0 to < 1.5\n1.5\n1.5\n1.5\n1.5\n1.5\n≥ 1.5 to < 2.0\n1.5\n1.5\n1.5\n1.5\n1.5\n≥ 2.0\n1.5\n1.5\n1.5\n2.0\n2.0\nNo\n< 1.0\n2.0\n2.5\n4.0\n5.0\nX\n≥ 1.0 to < 1.5\n1.5\n1.5\n1.5\n1.5\n2.5\n≥ 1.5 to < 2.0\n1.5\n1.5\n1.5\n2.0\n2.0\n≥ 2.0\n1.5\n1.5\n1.5\n1.5\n1.5\nStandard\nYes\n< 1.0\n1.5\n1.5\n2.0\n3.0\n4.0\n≥ 1.0 to < 1.5\n1.5\n1.5\n1.5\n1.5\n2.5\n≥ 1.5 to < 2.0\n1.5\n1.5\n1.5\n1.5\n2.0\n≥ 2.0\n1.5\n1.5\n1.5\n1.5\n1.5\nNo\n< 1.0\n2.5\n4.0\n6.0\nX\nX\n≥ 1.0 to < 1.5\n1.5\n1.5\n1.5\n1.5\n4.0\n≥ 1.5 to < 2.0\n1.5\n1.5\n2.0\n2.0\n2.5\n≥ 2.0\n1.5\n1.5\n1.5\n2.0\n2.5\nTable Notes\nSA = solar absorptance.\nA roof space is to be considered ‘vented’ if it—\nhas one wind-driven roof ventilator per 50 m2 of ceiling area with gable, eave or ridge vents; or\nhas one powered roof ventilator per 200 m2 of ceiling area with gable, eave or ridge vents; or\nis a tiled roof without sarking-type material at roof level.\nIf a roof is not ‘vented’, it is a ‘standard’ roof.\nThe R-Value of reflective insulation is not to be included in the R-Value of any under-roof or ceiling insulation.\nR-Values listed are for the labelled, declared R-Value of insulation.\nX = not permitted.\nTable J3D7c Timber-framed flat, skillion or cathedral roof — minimum R-Value for ceiling insulation: climate zone 1\nReflective insulation under-roof\nSA ≤ 0.23\nSA > 0.23 to ≤ 0.32\nSA > 0.32 to ≤ 0.42\nSA > 0.42 to ≤ 0.53\nSA > 0.53 to ≤ 0.64\nYes\n1.5\n1.5\n2.0\n3.0\n4.0\nNo\n1.5\n3.5\n5.0\nX\nX\nTable Notes\nSA = solar absorptance.\nThe R-Value can be achieved by installing insulation under the roof or on top of the ceiling or a combination of both.\nThe R-Value of reflective insulation is not to be included in the R-Value of any under-roof or ceiling insulation.\nR-Values listed are for the labelled, declared R-Value of insulation.\nX = not permitted.\nTable J3D7d Flat concrete roof — minimum R-Value for ceiling insulation: climate zone 2\nReflective insulation under-roof\nSA ≤ 0.23\nSA > 0.23 to ≤ 0.32\nSA > 0.32 to ≤ 0.42\nSA > 0.42 to ≤ 0.53\nSA > 0.53 to ≤ 0.64\nYes\n2.0\n2.5\n2.5\n3.0\n3.5\nNo\n3.0\n3.0\n3.5\n4.0\n4.5\nTable Notes\nSA = solar absorptance.\nThe R-Value of reflective insulation is not to be included in the R-Value of any under-roof or ceiling insulation.\nR-Values listed are for the labelled, declared R-Value of insulation.\nTable J3D7e Timber-framed pitched roof with horizontal ceiling — minimum R-Value for ceiling insulation: climate zone 2\nRoof ventilation\nReflective insulation under-roof\nUnder-roof insulation R-Value\nSA ≤ 0.23\nSA > 0.23 to ≤ 0.32\nSA > 0.32 to ≤ 0.42\nSA > 0.42 to ≤ 0.53\nSA > 0.53 to ≤ 0.64\nVented\nYes\nAny\n2.5\nNo\n0 to < 0.5\n2.5\n3.0\n3.0\n3.5\n3.5\n≥ 0.5\n2.5\nStandard\nYes\nAny\n2.5\nNo\n0 to < 0.5\n3.0\n3.0\n3.5\n4.0\n4.0\n≥ 0.5 to < 1.0\n2.5\n2.5\n2.5\n3.0\n3.0\n≥ 1.0\n2.5\nTable Notes\nSA = solar absorptance.\nA roof is considered ‘vented’ if it—\nhas one wind-driven roof ventilator per 50 m2 of ceiling area with gable, eave or ridge vents; or\nhas one powered roof ventilator per 200 m2 of ceiling area with gable, eave or ridge vents; or\nis a tiled roof without sarking-type material at roof level.\nIf a roof is not ‘vented’, it is a ‘standard’ roof.\nThe R-Value of reflective insulation is not to be included in the R-Value of any under-roof or ceiling insulation.\nR-Values listed are for the labelled, declared R-Value of insulation.\nTable J3D7f Timber-framed flat, skillion or cathedral roof — minimum R-Value for ceiling insulation: climate zone 2\nReflective insulation under-roof\nSA ≤ 0.23\nSA > 0.23 to ≤ 0.32\nSA > 0.32 to ≤ 0.42\nSA > 0.42 to ≤ 0.53\nSA > 0.53 to ≤ 0.64\nYes\n2.5\n2.5\n2.5\n2.5\n2.5\nNo\n3.0\n3.0\n3.5\n4.0\n4.0\nTable Notes\nSA = solar absorptance.\nThe R-Value can be achieved by installing insulation under the roof or on top of the ceiling or a combination of both.\nThe R-Value of reflective insulation is not to be included in the R-Value of any under-roof or ceiling insulation.\nR-Values listed are for the labelled, declared R-Value of insulation.\nTable J3D7g Flat concrete roof — minimum R-Value for ceiling insulation: climate zone 3\nReflective insulation under-roof\nSA ≤ 0.23\nSA > 0.23 to ≤ 0.32\nSA > 0.32 to ≤ 0.42\nSA > 0.42 to ≤ 0.53\nSA > 0.53 to ≤ 0.64\nYes\n2.0\n2.0\n2.5\n2.5\n3.0\nNo\n3.0\n3.5\n4.0\n4.5\n5.0\nTable Notes\nSA = solar absorptance.\nThe R-Value of reflective insulation is not to be included in the R-Value of any under-roof or ceiling insulation.\nR-Values listed are for the labelled, declared R-Val","g":"/ncc/j3d7"},{"c":"Table J3D8a","t":"Solar absorptance – climate zones 1 to 6","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_2e8e27fa-5dbc-4b68-8ef7-a5a5aa0cc14e","x":"Climate zone | Opaque external wall to net floor area ratio | Permitted solar absorptance\n1 and 3 | < 45% | ≤ 0.8\n≥ 45% | ≤ 0.35\n2 | < 35% | Any\n≥ 35% | Any, or ≤ 0.35, if shading device overhang is < 300 mm\n4 and 5 | < 45% | Any\n≥ 45% | ≤ 0.35, if shading device overhang is < 1500 mm\n6 | Any | Any","tb":"J3D8","g":"/ncc/table-j3d8a"},{"c":"Table J3D8b","t":"Solar absorptance – climate zones 7 and 8","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_f40f0765-3070-4e94-8bea-c71f8010ec7a","x":"Opaque external wall to net floor area ratio | Shading device overhang (mm)\n≥ 0 to < 600 | ≥ 600 to < 900 | ≥ 900 to < 1200 | ≥ 1200\n< 20% | Any | Any | ≥ 0.4 | X\n≥ 20% to < 35% | Any | Any | X | X\n≥ 35% to < 45% | Any | ≥ 0.4 | X | X\n≥ 45% | Any | ≥ 0.6 | X | X\nTable Notes\nX = not permitted","tb":"J3D8","g":"/ncc/table-j3d8b"},{"c":"J3D8","t":"External walls of a Class 4 part of a building","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#J3D8","x":"(1) The Total R-Value of an external wall —\nin climate zones 1, 2, 3, 5 and 6—\nwhere the ratio of the area of opaque external walls to the floor area of the sole-occupancy unit is less than 20%, must be at least R1.15; and\nwhere the ratio of the area of opaque external walls to the floor area of the sole-occupancy unit is greater than or equal to 20% but less than 35%, must be at least R2.04; and\nwhere the ratio of the area of opaque external walls to the floor area of the sole-occupancy unit is greater than or equal to 35%, must be at least R2.24; and\nin climate zones 4, 7 and 8, must be at least R2.24.\n(2) The Total R-Value of an external wall must be determined in accordance with—\nfor a spandrel panel in a curtain wall system, in accordance with Specification 38; and\nfor all other walls, in accordance with AS/NZS 4859.2.\n(3) The solar absorptance of an external wall must—\nin climate zones 1 to 6, be in accordance with Table J3D8a; and\nin climate zones 7 and 8, be in accordance with Table J3D8b.\nTable J3D8a Solar absorptance – climate zones 1 to 6\nClimate zone\nOpaque external wall to net floor area ratio\nPermitted solar absorptance\n1 and 3\n< 45%\n≤ 0.8\n≥ 45%\n≤ 0.35\n2\n< 35%\nAny\n≥ 35%\nAny, or ≤ 0.35, if shading device overhang is < 300 mm\n4 and 5\n< 45%\nAny\n≥ 45%\n≤ 0.35, if shading device overhang is < 1500 mm\n6\nAny\nAny\nTable J3D8b Solar absorptance – climate zones 7 and 8\nOpaque external wall to net floor area ratio\nShading device overhang (mm)\n≥ 0 to < 600\n≥ 600 to < 900\n≥ 900 to < 1200\n≥ 1200\n< 20%\nAny\nAny\n≥ 0.4\nX\n≥ 20% to < 35%\nAny\nAny\nX\nX\n≥ 35% to < 45%\nAny\n≥ 0.4\nX\nX\n≥ 45%\nAny\n≥ 0.6\nX\nX\nTable Notes\nX = not permitted","g":"/ncc/j3d8"},{"c":"Table J3D9","t":"Maximum wall-glazing construction solar admittance","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_d7854fbc-3f2c-4b21-b965-1edf606c6660","x":"Climate zone | Eastern aspect solar admittance | Northern aspect solar admittance | Southern aspect solar admittance | Western aspect solar admittance\n1 | 0.10 | 0.10 | 0.14 | 0.10\n2 | 0.10 | 0.10 | 0.10 | 0.10\n3 | 0.11 | 0.11 | 0.11 | 0.11\n4 | 0.11 | 0.11 | 0.11 | 0.11\n5 | 0.13 | 0.13 | 0.13 | 0.13\n6 | 0.14 | 0.14 | 0.14 | 0.14\n7 | N/A | N/A | N/A | N/A\n8 | N/A | N/A | N/A | N/A","tb":"J3D9","g":"/ncc/table-j3d9"},{"c":"J3D9","t":"Wall-glazing construction of a Class 4 part of a building","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#J3D9","x":"(1) The Total System U-Value of wall-glazing construction that forms part of the external building fabric must not be greater than—\nin climate zones 1 to 5, U2.2; or\nin climate zone 6, U2.0; or\nin climate zones 7 and 8, U1.4.\n(2) The Total System U-Value of wall-glazing construction that forms part of the external building fabric must be calculated in accordance with Specification 37.\n(3) Wall components of wall-glazing construction must achieve a minimum Total R-Value of—\nwhere the wall is less than 80% of the area of the wall-glazing construction, R1.0; or\nwhere the wall is 80% or more of the area of the wall-glazing construction, the value specified in Table J4D6b for a Class 3 building.\n(4) In climate zones 1 to 6, the solar admittance of externally facing wall-glazing construction must be not greater than that shown in Table J3D 9.\n(5) In climate zones 7 and 8, glazing in a wall-glazing construction must have a Total System SHGC of at least 0.4.\n(6) The solar admittance of a wall-glazing construction must be calculated in accordance with Specification 37 as for a Class 3 building as required.\n(7) The solar absorptance of an external wall must be in accordance with J3D8(3).\nTable J3D9 Maximum wall-glazing construction solar admittance\nClimate zone\nEastern aspect solar admittance\nNorthern aspect solar admittance\nSouthern aspect solar admittance\nWestern aspect solar admittance\n1\n0.10\n0.10\n0.14\n0.10\n2\n0.10\n0.10\n0.10\n0.10\n3\n0.11\n0.11\n0.11\n0.11\n4\n0.11\n0.11\n0.11\n0.11\n5\n0.13\n0.13\n0.13\n0.13\n6\n0.14\n0.14\n0.14\n0.14\n7\nN/A\nN/A\nN/A\nN/A\n8\nN/A\nN/A\nN/A\nN/A","g":"/ncc/j3d9"},{"c":"J3D10","t":"Floors of a Class 4 part of a building","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#J3D10","x":"(1) Where a Class 4 part of a building has a concrete floor above an unenclosed carpark, undercroft or the like, underfloor insulation must be installed with an R-Value at least—\nin climate zone 2 and climate zones 5 to 8, R2.0; and\nin climate zones 3 and 4, R1.5.\n(2) Where a Class 4 part of a building has a concrete floor above an enclosed carpark, undercroft or the like, underfloor insulation must be installed with an R-Value at least—\nin climate zone 2, R0.5; and\nin climate zones 4 and 5, R1.0; and\nin climate zone 6, R1.5; and\nin climate zones 7 and 8, R2.0.\n(3) A concrete slab-on-ground, including a waffle-pod slab, with an in-slab or in-screed heating or cooling system must have insulation with an R-Value at least 1.0 installed around the vertical edge of its perimeter.\n(4) A concrete slab-on-ground, other than a waffle-pod slab, must be insulated in accordance with the following:\nIn climate zones 6 and 7—\ninsulation with an R-Value of at least 0.64 must be installed around the vertical edge of its perimeter; and\ninsulation with an R-Value of at least 0.64 must be installed underneath the slab.\nIn climate zone 8—\ninsulation with an R-Value of at least 1.0 must be installed around the vertical edge of its perimeter; and\ninsulation with an R-Value of at least 2.0 must be installed underneath the slab.\n(5) Insulation required by (3), (4)(a)(i) and (4)(b)(i) must—\nbe water resistant; and\nbe continuous from the adjacent finished ground level—\nto a depth of not less than 300 mm; or\nfor at least the full depth of the vertical edge of the concrete slab-on-ground.\n(6) The requirements of (3) do not apply to an in-screed heating or cooling system used solely in a bathroom, amenity area or the like.","g":"/ncc/j3d10"},{"c":"Table J3D11a","t":"Maximum conductance to solar heat gain ratio (CU/CSHGC)","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_dd550f01-669a-4d4c-8bb7-edda46f43ac8","x":"Climate zone | Maximum conductance to solar heat gain ratio (CU/CSHGC)\n2 | 16.95\n3 | 19.88\n4 | 13.34\n5 | 11.83\n6 | 6.27\n7 | 12.90\n8 | 12.90","tb":"J3D11","g":"/ncc/table-j3d11a"},{"c":"Table J3D11b","t":"Orientation sector winter exposure factor (EW): climate zone 2","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_4e47ef40-67be-47c8-b5b3-961605d46ca3","x":"P/H | North | North east | East | South east | South | South west | West | North west\n0.00 | 1.49 | 1.61 | 1.23 | 0.96 | 0.68 | 1.03 | 1.37 | 1.71\n0.05 | 1.44 | 1.53 | 1.14 | 0.81 | 0.57 | 0.90 | 1.27 | 1.64\n0.10 | 1.38 | 1.48 | 1.09 | 0.76 | 0.53 | 0.85 | 1.22 | 1.55\n0.20 | 1.21 | 1.32 | 0.97 | 0.69 | 0.50 | 0.75 | 1.10 | 1.39\n0.40 | 1.00 | 1.06 | 0.77 | 0.57 | 0.42 | 0.63 | 0.92 | 1.14\n0.60 | 0.83 | 0.87 | 0.69 | 0.50 | 0.37 | 0.55 | 0.77 | 0.96\n0.80 | 0.62 | 0.69 | 0.56 | 0.43 | 0.35 | 0.50 | 0.66 | 0.79\n1.00 | 0.43 | 0.59 | 0.46 | 0.41 | 0.33 | 0.43 | 0.56 | 0.65\n1.20 | 0.26 | 0.47 | 0.40 | 0.36 | 0.31 | 0.40 | 0.53 | 0.53\n1.40 | 0.22 | 0.40 | 0.33 | 0.33 | 0.29 | 0.38 | 0.47 | 0.44\n1.60 | 0.18 | 0.32 | 0.31 | 0.33 | 0.28 | 0.35 | 0.39 | 0.39\n1.80 | 0.15 | 0.28 | 0.27 | 0.31 | 0.26 | 0.33 | 0.35 | 0.32\n2.00 | 0.12 | 0.21 | 0.24 | 0.29 | 0.26 | 0.33 | 0.33 | 0.31","tb":"J3D11","g":"/ncc/table-j3d11b"},{"c":"Table J3D11c","t":"Orientation sector winter exposure factor (EW): climate zone 3","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_0f430da7-82fb-45cb-9840-066d9ae25717","x":"P/H | North | North east | East | South east | South | South west | West | North west\n0.00 | 0.90 | 1.10 | 0.88 | 0.69 | 0.50 | 0.58 | 0.67 | 0.91\n0.05 | 0.89 | 1.06 | 0.82 | 0.60 | 0.44 | 0.51 | 0.64 | 0.89\n0.10 | 0.83 | 1.01 | 0.78 | 0.58 | 0.42 | 0.49 | 0.61 | 0.84\n0.20 | 0.74 | 0.90 | 0.70 | 0.52 | 0.40 | 0.44 | 0.55 | 0.76\n0.40 | 0.59 | 0.74 | 0.60 | 0.43 | 0.36 | 0.37 | 0.47 | 0.63\n0.60 | 0.44 | 0.57 | 0.48 | 0.39 | 0.34 | 0.32 | 0.38 | 0.51\n0.80 | 0.30 | 0.45 | 0.43 | 0.34 | 0.30 | 0.30 | 0.32 | 0.41\n1.00 | 0.20 | 0.38 | 0.35 | 0.30 | 0.28 | 0.28 | 0.29 | 0.33\n1.20 | 0.14 | 0.29 | 0.31 | 0.28 | 0.28 | 0.25 | 0.24 | 0.28\n1.40 | 0.11 | 0.26 | 0.25 | 0.26 | 0.26 | 0.23 | 0.21 | 0.24\n1.60 | 0.08 | 0.23 | 0.24 | 0.24 | 0.24 | 0.21 | 0.20 | 0.20\n1.80 | 0.07 | 0.16 | 0.19 | 0.24 | 0.24 | 0.19 | 0.17 | 0.18\n2.00 | 0.06 | 0.16 | 0.18 | 0.21 | 0.24 | 0.19 | 0.15 | 0.16","tb":"J3D11","g":"/ncc/table-j3d11c"},{"c":"Table J3D11d","t":"Orientation sector winter exposure factor (EW): climate zone 4","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_99c7f645-c86d-4f53-af94-990585c05ce7","x":"P/H | North | North east | East | South east | South | South west | West | North west\n0.00 | 1.58 | 1.66 | 1.16 | 0.93 | 0.70 | 0.78 | 0.85 | 1.38\n0.05 | 1.54 | 1.60 | 1.06 | 0.79 | 0.58 | 0.66 | 0.79 | 1.32\n0.10 | 1.53 | 1.54 | 1.04 | 0.74 | 0.56 | 0.62 | 0.75 | 1.28\n0.20 | 1.30 | 1.41 | 0.94 | 0.67 | 0.50 | 0.56 | 0.68 | 1.15\n0.40 | 1.18 | 1.20 | 0.78 | 0.57 | 0.44 | 0.48 | 0.58 | 0.99\n0.60 | 0.98 | 0.99 | 0.69 | 0.50 | 0.38 | 0.42 | 0.49 | 0.81\n0.80 | 0.85 | 0.81 | 0.60 | 0.45 | 0.36 | 0.38 | 0.44 | 0.68\n1.00 | 0.68 | 0.73 | 0.52 | 0.41 | 0.32 | 0.34 | 0.37 | 0.58\n1.20 | 0.49 | 0.56 | 0.46 | 0.36 | 0.32 | 0.32 | 0.34 | 0.50\n1.40 | 0.38 | 0.52 | 0.42 | 0.33 | 0.30 | 0.30 | 0.30 | 0.42\n1.60 | 0.27 | 0.45 | 0.39 | 0.33 | 0.28 | 0.28 | 0.26 | 0.37\n1.80 | 0.21 | 0.39 | 0.35 | 0.31 | 0.28 | 0.26 | 0.24 | 0.32\n2.00 | 0.19 | 0.35 | 0.31 | 0.29 | 0.26 | 0.24 | 0.22 | 0.26","tb":"J3D11","g":"/ncc/table-j3d11d"},{"c":"Table J3D11e","t":"Orientation sector winter exposure factor (EW): climate zone 5","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_669d2ca7-d4a8-471b-8ced-177072530e4c","x":"P/H | North | North east | East | South east | South | South west | West | North west\n0.00 | 1.61 | 1.34 | 1.08 | 0.87 | 0.67 | 0.76 | 0.85 | 1.23\n0.05 | 1.56 | 1.29 | 0.98 | 0.74 | 0.56 | 0.64 | 0.78 | 1.17\n0.10 | 1.56 | 1.23 | 0.92 | 0.69 | 0.54 | 0.62 | 0.75 | 1.14\n0.20 | 1.30 | 1.10 | 0.83 | 0.63 | 0.49 | 0.54 | 0.67 | 1.03\n0.40 | 1.19 | 0.91 | 0.69 | 0.54 | 0.41 | 0.47 | 0.55 | 0.86\n0.60 | 0.97 | 0.75 | 0.56 | 0.47 | 0.38 | 0.41 | 0.47 | 0.70\n0.80 | 0.78 | 0.62 | 0.49 | 0.42 | 0.34 | 0.37 | 0.42 | 0.57\n1.00 | 0.64 | 0.47 | 0.39 | 0.38 | 0.32 | 0.33 | 0.36 | 0.49\n1.20 | 0.43 | 0.42 | 0.35 | 0.36 | 0.31 | 0.31 | 0.29 | 0.39\n1.40 | 0.32 | 0.31 | 0.29 | 0.34 | 0.29 | 0.29 | 0.28 | 0.33\n1.60 | 0.22 | 0.27 | 0.27 | 0.31 | 0.25 | 0.25 | 0.23 | 0.28\n1.80 | 0.18 | 0.23 | 0.22 | 0.29 | 0.25 | 0.25 | 0.20 | 0.25\n2.00 | 0.14 | 0.17 | 0.21 | 0.27 | 0.25 | 0.23 | 0.19 | 0.19","tb":"J3D11","g":"/ncc/table-j3d11e"},{"c":"Table J3D11f","t":"Orientation sector winter exposure factor (EW): climate zone 6","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_c85dd293-77be-4bb1-a060-945ac200ded3","x":"P/H | North | North east | East | South east | South | South west | West | North west\n0.00 | 3.04 | 2.50 | 1.52 | 1.51 | 1.51 | 1.63 | 1.76 | 2.75\n0.05 | 2.94 | 2.36 | 1.39 | 1.28 | 1.26 | 1.38 | 1.62 | 2.61\n0.10 | 2.91 | 2.28 | 1.33 | 1.21 | 1.19 | 1.30 | 1.52 | 2.55\n0.20 | 2.50 | 2.05 | 1.18 | 1.08 | 1.05 | 1.16 | 1.40 | 2.34\n0.40 | 2.29 | 1.77 | 1.01 | 0.91 | 0.91 | 0.98 | 1.20 | 1.98\n0.60 | 1.95 | 1.51 | 0.86 | 0.77 | 0.81 | 0.83 | 1.04 | 1.71\n0.80 | 1.73 | 1.28 | 0.72 | 0.71 | 0.74 | 0.80 | 0.92 | 1.42\n1.00 | 1.38 | 1.02 | 0.65 | 0.64 | 0.67 | 0.69 | 0.78 | 1.24\n1.20 | 1.12 | 0.95 | 0.55 | 0.61 | 0.60 | 0.65 | 0.72 | 1.04\n1.40 | 0.85 | 0.72 | 0.49 | 0.54 | 0.60 | 0.62 | 0.64 | 0.93\n1.60 | 0.70 | 0.65 | 0.42 | 0.50 | 0.56 | 0.54 | 0.56 | 0.79\n1.80 | 0.51 | 0.53 | 0.40 | 0.47 | 0.53 | 0.51 | 0.54 | 0.72\n2.00 | 0.40 | 0.47 | 0.38 | 0.44 | 0.49 | 0.51 | 0.48 | 0.58","tb":"J3D11","g":"/ncc/table-j3d11f"},{"c":"Table J3D11g","t":"Orientation sector winter exposure factor (EW): climate zones 7 and 8","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_282fdb41-d3a5-4b1b-943d-658c55f2df81","x":"P/H | North | North east | East | South east | South | South west | West | North west\n0.00 | 1.66 | 1.53 | 0.90 | 0.82 | 0.74 | 0.78 | 0.83 | 1.43\n0.05 | 1.61 | 1.47 | 0.83 | 0.69 | 0.61 | 0.66 | 0.76 | 1.37\n0.10 | 1.61 | 1.44 | 0.79 | 0.64 | 0.59 | 0.62 | 0.73 | 1.34\n0.20 | 1.51 | 1.34 | 0.73 | 0.58 | 0.53 | 0.55 | 0.66 | 1.22\n0.40 | 1.30 | 1.17 | 0.63 | 0.49 | 0.44 | 0.47 | 0.55 | 1.07\n0.60 | 1.19 | 1.02 | 0.54 | 0.43 | 0.40 | 0.41 | 0.48 | 0.91\n0.80 | 1.02 | 0.88 | 0.48 | 0.39 | 0.36 | 0.37 | 0.43 | 0.79\n1.00 | 0.93 | 0.78 | 0.44 | 0.34 | 0.34 | 0.33 | 0.37 | 0.67\n1.20 | 0.73 | 0.66 | 0.37 | 0.32 | 0.32 | 0.31 | 0.33 | 0.60\n1.40 | 0.66 | 0.64 | 0.36 | 0.30 | 0.29 | 0.29 | 0.30 | 0.46\n1.60 | 0.51 | 0.46 | 0.32 | 0.28 | 0.27 | 0.25 | 0.28 | 0.43\n1.80 | 0.42 | 0.44 | 0.26 | 0.26 | 0.27 | 0.25 | 0.25 | 0.37\n2.00 | 0.31 | 0.37 | 0.26 | 0.24 | 0.25 | 0.25 | 0.22 | 0.31","tb":"J3D11","g":"/ncc/table-j3d11g"},{"c":"Table J3D11h","t":"Conductance and radiation factors: climate zone 2","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_dbc03977-d029-4f68-887d-91fcaaf218dd","x":"Type of factor | Factor\nBedroom conduction weighting factor (BC) | 0.43\nRoom type multiplier (for bedroom and unconditioned areas) (RW) | 1.00\nBedroom solar heat gain weighting factor (BSW) | 0.40\nFloor factor for tiled or vinyl covered floors (HW) | 1.02\nFloor factor for other than tiled or vinyl covered floors (HW) | 0.96","tb":"J3D11","g":"/ncc/table-j3d11h"},{"c":"Table J3D11i","t":"Conductance and radiation factors: climate zone 3","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_7f11cae7-abfc-4afb-a771-4ccaf69349bb","x":"Type of factor | Factor\nBedroom conduction weighting factor (BC) | 0.42\nRoom type multiplier (for bedroom and unconditioned areas) (RW) | 1.00\nBedroom solar heat gain weighting factor (BSW) | 1.28\nFloor factor for tiled or vinyl covered floors (HW) | 1.02\nFloor factor for other than tiled or vinyl covered floors (HW) | 0.97","tb":"J3D11","g":"/ncc/table-j3d11i"},{"c":"Table J3D11j","t":"Conductance and radiation factors: climate zone 4","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_c3660c35-2332-40c1-9d75-e82fa1f59e6b","x":"Type of factor | Factor\nBedroom conduction weighting factor (BC) | 0.70\nRoom type multiplier (for bedroom and unconditioned areas) (RW) | 1.00\nBedroom solar heat gain weighting factor (BSW) | 0.60\nFloor factor for tiled or vinyl covered floors (HW) | 1.04\nFloor factor for other than tiled or vinyl covered floors (HW) | 0.92","tb":"J3D11","g":"/ncc/table-j3d11j"},{"c":"Table J3D11k","t":"Conductance and radiation factors: climate zone 5","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_6186b460-0f6c-4ef0-83a0-d12387f30476","x":"Type of factor | Factor\nBedroom conduction weighting factor (BC) | 0.63\nRoom type multiplier (for bedroom and unconditioned areas) (RW) | 1.10\nBedroom solar heat gain weighting factor (BSW) | 0.81\nFloor factor for tiled or vinyl covered floors (HW) | 1.03\nFloor factor for other than tiled or vinyl covered floors (HW) | 0.93","tb":"J3D11","g":"/ncc/table-j3d11k"},{"c":"Table J3D11l","t":"Conductance and radiation factors: climate zone 6","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_e9272cc9-6d78-4fd2-beeb-0177388625c1","x":"Type of factor | Factor\nBedroom conduction weighting factor (BC) | 0.81\nRoom type multiplier (for bedroom and unconditioned areas) (RW) | 1.00\nBedroom solar heat gain weighting factor (BSW) | 0.65\nFloor factor for tiled or vinyl covered floors (HW) | 1.02\nFloor factor for other than tiled or vinyl covered floors (HW) | 0.98","tb":"J3D11","g":"/ncc/table-j3d11l"},{"c":"Table J3D11m","t":"Conductance and radiation factors: climate zones 7 and 8","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_2fe8a586-1f9f-4a6f-a848-f3aca4bce533","x":"Type of factor | Factor\nBedroom conduction weighting factor (BC) | 0.60\nRoom type multiplier (for bedroom and unconditioned areas) (RW) | 1.00\nBedroom solar heat gain weighting factor (BSW) | 0.51\nFloor factor for tiled or vinyl covered floors (HW) | 1.03\nFloor factor for other than tiled or vinyl covered floors (HW) | 0.93","tb":"J3D11","g":"/ncc/table-j3d11m"},{"c":"Table J3D11n","t":"Orientation sector conductance factor (OC)","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_baa9b580-03d0-4409-9d89-fb5015e2352a","x":"Climate zone | North | North east | East | South east | South | South west | West | North west\n2 | 1.70 | 1.34 | 0.98 | 0.84 | 0.70 | 0.90 | 1.10 | 1.40\n3 | 1.30 | 1.10 | 0.90 | 0.95 | 1.00 | 0.95 | 0.90 | 1.10\n4 | 1.30 | 1.25 | 1.20 | 1.03 | 0.85 | 0.92 | 0.99 | 1.15\n5 | 1.20 | 1.15 | 1.10 | 1.05 | 1.00 | 1.05 | 1.10 | 1.15\n6 | 1.23 | 1.13 | 1.00 | 1.00 | 1.02 | 1.00 | 1.00 | 1.16\n7 and 8 | 1.40 | 1.25 | 1.10 | 1.00 | 0.90 | 0.95 | 1.00 | 1.20","tb":"J3D11","g":"/ncc/table-j3d11n"},{"c":"Table J3D11o","t":"Frame factor (FW) — climate zone 2","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_ed1895b5-727a-48d2-9923-834f5215b29c","x":"Frame solar absorptance | Factor\n≤ 0.40 | 0.97\n> 0.40 to < 0.68 | 1.00\n≥ 0.68 | 1.08\nTable Notes\nInterpolation is allowed for values between those shown.","tb":"J3D11","g":"/ncc/table-j3d11o"},{"c":"Table J3D11p","t":"Frame factor (FW) — climate zone 3","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_cbe3a028-7ff2-479c-b37a-006682249408","x":"Frame solar absorptance | Factor\n≤ 0.40 | 0.98\n> 0.40 to < 0.68 | 1.00\n≥ 0.68 | 1.05\nTable Notes\nInterpolation is allowed for values between those shown.","tb":"J3D11","g":"/ncc/table-j3d11p"},{"c":"Table J3D11q","t":"Frame factor (FW) — climate zone 4","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_ffcc3dd5-5288-42aa-a150-d352eb06a75a","x":"Frame solar absorptance | Factor\n≤ 0.40 | 0.99\n> 0.40 to < 0.68 | 1.00\n≥ 0.68 | 1.01\nTable Notes\nInterpolation is allowed for values between those shown.","tb":"J3D11","g":"/ncc/table-j3d11q"},{"c":"Table J3D11r","t":"Frame factor (FW) — climate zone 5","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_a5b93065-e05f-4fe5-8cb9-4f718a028f7f","x":"Frame solar absorptance | Factor\n≤ 0.40 | 1.00\n> 0.40 to < 0.68 | 1.00\n≥ 0.68 | 1.01\nTable Notes\nInterpolation is allowed for values between those shown.","tb":"J3D11","g":"/ncc/table-j3d11r"},{"c":"Table J3D11s","t":"Frame factor (FW) — climate zone 6","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_d3482c4b-3bf2-49e7-8db0-87a46d5f9215","x":"Frame solar absorptance | Factor\n≤ 0.40 | 0.92\n> 0.40 to < 0.68 | 1.00\n≥ 0.68 | 1.13\nTable Notes\nInterpolation is allowed for values between those shown.","tb":"J3D11","g":"/ncc/table-j3d11s"},{"c":"Table J3D11t","t":"Frame factor (FW) — climate zones 7 and 8","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_0a9a7390-7234-4988-ac8e-611a08f04d9d","x":"Frame solar absorptance | Factor\n≤ 0.40 | 0.97\n> 0.40 to < 0.68 | 1.00\n≥ 0.68 | 1.01\nTable Notes\nInterpolation is allowed for values between those shown.","tb":"J3D11","g":"/ncc/table-j3d11t"},{"c":"J3D11","t":"External winter glazing of a Class 4 part of a building","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#J3D11","x":"(1) In climate zones 2 to 8, the ratio of the conductance (CU) and solar heat gain (CSHGC) of the glazing of each storey, including any mezzanine, of a Class 4 part of a building must—\nnot exceed the allowance obtained from Table J3D11a; and\nbe calculated in accordance with the following formula:\n[formula] (2) In the formula at (1)(b)—\n[formula] = the area of each glazing element; and\n[formula] = the Total System U-Value of each glazing element; and\n[formula] = the Total System SHGC for each glazing element, not exceeding 0.7; and\n[formula] = the winter exposure factor for each glazing element obtained from Table J3D11b, J3D11c, J3D11d, J3D11e, J3D11f or J3D11g; and\n[formula] = the bedroom conductance factor obtained from Table J3D11h, J3D11i, J3D11j, J3D11k, J3D11l or J3D11m; and\n[formula] = the orientation sector conductance factor obtained from Table J3D11n; and\n[formula] = the room type factor obtained from Table J3D11h, J3D11i, J3D11j, J3D11k, J3D11l or J3D11m; and\n[formula] = the bedroom solar heat gain factor obtained from Table J3D11h, J3D11i, J3D11j, J3D11k, J3D11l or J3D11m; and\n[formula] = the frame factor obtained from Table J3D11o, J3D11p, J3D11q, J3D11r, J3D11s or J3D11t for each glazing element; and\n[formula] = the floor factor obtained from Table J3D11h, J3D11i, J3D11j, J3D11k, J3D11l or J3D11m for each glazing element.\n(3) For the purpose of J3D11—\norientation sectors must be determined in accordance with Figure 13.3.2a of the ABCB Housing Provisions; and\nP/H must be determined in accordance with Figure S37C7a; and\nFor P/H between those in Tables J3D11b, J3D11c, J3D11d, J3D11e, J3D11f and J3D11g, either use the next highest P/H or interpolate.\nTable J3D11a Maximum conductance to solar heat gain ratio (CU/CSHGC)\nClimate zone\nMaximum conductance to solar heat gain ratio (CU/CSHGC)\n2\n16.95\n3\n19.88\n4\n13.34\n5\n11.83\n6\n6.27\n7\n12.90\n8\n12.90\nTable J3D11b Orientation sector winter exposure factor (EW): climate zone 2\nP/H\nNorth\nNorth east\nEast\nSouth east\nSouth\nSouth west\nWest\nNorth west\n0.00\n1.49\n1.61\n1.23\n0.96\n0.68\n1.03\n1.37\n1.71\n0.05\n1.44\n1.53\n1.14\n0.81\n0.57\n0.90\n1.27\n1.64\n0.10\n1.38\n1.48\n1.09\n0.76\n0.53\n0.85\n1.22\n1.55\n0.20\n1.21\n1.32\n0.97\n0.69\n0.50\n0.75\n1.10\n1.39\n0.40\n1.00\n1.06\n0.77\n0.57\n0.42\n0.63\n0.92\n1.14\n0.60\n0.83\n0.87\n0.69\n0.50\n0.37\n0.55\n0.77\n0.96\n0.80\n0.62\n0.69\n0.56\n0.43\n0.35\n0.50\n0.66\n0.79\n1.00\n0.43\n0.59\n0.46\n0.41\n0.33\n0.43\n0.56\n0.65\n1.20\n0.26\n0.47\n0.40\n0.36\n0.31\n0.40\n0.53\n0.53\n1.40\n0.22\n0.40\n0.33\n0.33\n0.29\n0.38\n0.47\n0.44\n1.60\n0.18\n0.32\n0.31\n0.33\n0.28\n0.35\n0.39\n0.39\n1.80\n0.15\n0.28\n0.27\n0.31\n0.26\n0.33\n0.35\n0.32\n2.00\n0.12\n0.21\n0.24\n0.29\n0.26\n0.33\n0.33\n0.31\nTable J3D11c Orientation sector winter exposure factor (EW): climate zone 3\nP/H\nNorth\nNorth east\nEast\nSouth east\nSouth\nSouth west\nWest\nNorth west\n0.00\n0.90\n1.10\n0.88\n0.69\n0.50\n0.58\n0.67\n0.91\n0.05\n0.89\n1.06\n0.82\n0.60\n0.44\n0.51\n0.64\n0.89\n0.10\n0.83\n1.01\n0.78\n0.58\n0.42\n0.49\n0.61\n0.84\n0.20\n0.74\n0.90\n0.70\n0.52\n0.40\n0.44\n0.55\n0.76\n0.40\n0.59\n0.74\n0.60\n0.43\n0.36\n0.37\n0.47\n0.63\n0.60\n0.44\n0.57\n0.48\n0.39\n0.34\n0.32\n0.38\n0.51\n0.80\n0.30\n0.45\n0.43\n0.34\n0.30\n0.30\n0.32\n0.41\n1.00\n0.20\n0.38\n0.35\n0.30\n0.28\n0.28\n0.29\n0.33\n1.20\n0.14\n0.29\n0.31\n0.28\n0.28\n0.25\n0.24\n0.28\n1.40\n0.11\n0.26\n0.25\n0.26\n0.26\n0.23\n0.21\n0.24\n1.60\n0.08\n0.23\n0.24\n0.24\n0.24\n0.21\n0.20\n0.20\n1.80\n0.07\n0.16\n0.19\n0.24\n0.24\n0.19\n0.17\n0.18\n2.00\n0.06\n0.16\n0.18\n0.21\n0.24\n0.19\n0.15\n0.16\nTable J3D11d Orientation sector winter exposure factor (EW): climate zone 4\nP/H\nNorth\nNorth east\nEast\nSouth east\nSouth\nSouth west\nWest\nNorth west\n0.00\n1.58\n1.66\n1.16\n0.93\n0.70\n0.78\n0.85\n1.38\n0.05\n1.54\n1.60\n1.06\n0.79\n0.58\n0.66\n0.79\n1.32\n0.10\n1.53\n1.54\n1.04\n0.74\n0.56\n0.62\n0.75\n1.28\n0.20\n1.30\n1.41\n0.94\n0.67\n0.50\n0.56\n0.68\n1.15\n0.40\n1.18\n1.20\n0.78\n0.57\n0.44\n0.48\n0.58\n0.99\n0.60\n0.98\n0.99\n0.69\n0.50\n0.38\n0.42\n0.49\n0.81\n0.80\n0.85\n0.81\n0.60\n0.45\n0.36\n0.38\n0.44\n0.68\n1.00\n0.68\n0.73\n0.52\n0.41\n0.32\n0.34\n0.37\n0.58\n1.20\n0.49\n0.56\n0.46\n0.36\n0.32\n0.32\n0.34\n0.50\n1.40\n0.38\n0.52\n0.42\n0.33\n0.30\n0.30\n0.30\n0.42\n1.60\n0.27\n0.45\n0.39\n0.33\n0.28\n0.28\n0.26\n0.37\n1.80\n0.21\n0.39\n0.35\n0.31\n0.28\n0.26\n0.24\n0.32\n2.00\n0.19\n0.35\n0.31\n0.29\n0.26\n0.24\n0.22\n0.26\nTable J3D11e Orientation sector winter exposure factor (EW): climate zone 5\nP/H\nNorth\nNorth east\nEast\nSouth east\nSouth\nSouth west\nWest\nNorth west\n0.00\n1.61\n1.34\n1.08\n0.87\n0.67\n0.76\n0.85\n1.23\n0.05\n1.56\n1.29\n0.98\n0.74\n0.56\n0.64\n0.78\n1.17\n0.10\n1.56\n1.23\n0.92\n0.69\n0.54\n0.62\n0.75\n1.14\n0.20\n1.30\n1.10\n0.83\n0.63\n0.49\n0.54\n0.67\n1.03\n0.40\n1.19\n0.91\n0.69\n0.54\n0.41\n0.47\n0.55\n0.86\n0.60\n0.97\n0.75\n0.56\n0.47\n0.38\n0.41\n0.47\n0.70\n0.80\n0.78\n0.62\n0.49\n0.42\n0.34\n0.37\n0.42\n0.57\n1.00\n0.64\n0.47\n0.39\n0.38\n0.32\n0.33\n0.36\n0.49\n1.20\n0.43\n0.42\n0.35\n0.36\n0.31\n0.31\n0.29\n0.39\n1.40\n0.32\n0.31\n0.29\n0.34\n0.29\n0.29\n0.28\n0.33\n1.60\n0.22\n0.27\n0.27\n0.31\n0.25\n0.25\n0.23\n0.28\n1.80\n0.18\n0.23\n0.22\n0.29\n0.25\n0.25\n0.20\n0.25\n2.00\n0.14\n0.17\n0.21\n0.27\n0.25\n0.23\n0.19\n0.19\nTable J3D11f Orientation sector winter exposure factor (EW): climate zone 6\nP/H\nNorth\nNorth east\nEast\nSouth east\nSouth\nSouth west\nWest\nNorth west\n0.00\n3.04\n2.50\n1.52\n1.51\n1.51\n1.63\n1.76\n2.75\n0.05\n2.94\n2.36\n1.39\n1.28\n1.26\n1.38\n1.62\n2.61\n0.10\n2.91\n2.28\n1.33\n1.21\n1.19\n1.30\n1.52\n2.55\n0.20\n2.50\n2.05\n1.18\n1.08\n1.05\n1.16\n1.40\n2.34\n0.40\n2.29\n1.77\n1.01\n0.91\n0.91\n0.98\n1.20\n1.98\n0.60\n1.95\n1.51\n0.86\n0.77\n0.81\n0.83\n1.04\n1.71\n0.80\n1.73\n1.28\n0.72\n0.71\n0.74\n0.80\n0.92\n1.42\n1.00\n1.38\n1.02\n0.65\n0.64\n0.67\n0.69\n0.78\n1.24\n1.20\n1.12\n0.95\n0.55\n0.61\n0.60\n0.65\n0.72\n1.04\n1.40\n0.85\n0.72\n0.49\n0.54\n0.60\n0.62\n0.64\n0.93\n1.60\n0.70\n0.65\n0.42\n0.50\n0.56\n0.54\n0.56\n0.79\n1.80\n0.51\n0.53\n0.40\n0.47\n0.53\n0.51\n0.54\n0.72\n2.00\n0.40\n0.47\n0.38\n0.44\n0.49\n0.51\n0.48\n0.58\nTable J3D11g Orientation sector winter exposure factor (EW): climate zones 7 and 8\nP/H\nNorth\nNorth east\nEast\nSouth east\nSouth\nSouth west\nWest\nNorth west\n0.00\n1.66\n1.53\n0.90\n0.82\n0.74\n0.78\n0.83\n1.43\n0.05\n1.61\n1.47\n0.83\n0.69\n0.61\n0.66\n0.76\n1.37\n0.10\n1.61\n1.44\n0.79\n0.64\n0.59\n0.62\n0.73\n1.34\n0.20\n1.51\n1.34\n0.73\n0.58\n0.53\n0.55\n0.66\n1.22\n0.40\n1.30\n1.17\n0.63\n0.49\n0.44\n0.47\n0.55\n1.07\n0.60\n1.19\n1.02\n0.54\n0.43\n0.40\n0.41\n0.48\n0.91\n0.80\n1.02\n0.88\n0.48\n0.39\n0.36\n0.37\n0.43\n0.79\n1.00\n0.93\n0.78\n0.44\n0.34\n0.34\n0.33\n0.37\n0.67\n1.20\n0.73\n0.66\n0.37\n0.32\n0.32\n0.31\n0.33\n0.60\n1.40\n0.66\n0.64\n0.36\n0.30\n0.29\n0.29\n0.30\n0.46\n1.60\n0.51\n0.46\n0.32\n0.28\n0.27\n0.25\n0.28\n0.43\n1.80\n0.42\n0.44\n0.26\n0.26\n0.27\n0.25\n0.25\n0.37\n2.00\n0.31\n0.37\n0.26\n0.24\n0.25\n0.25\n0.22\n0.31\nTable J3D11h Conductance and radiation factors: climate zone 2\nType of factor\nFactor\nBedroom conduction weighting factor (BC)\n0.43\nRoom type multiplier (for bedroom and unconditioned areas) (RW)\n1.00\nBedroom solar heat gain weighting factor (BSW)\n0.40\nFloor factor for tiled or vinyl covered floors (HW)\n1.02\nFloor factor for other than tiled or vinyl covered floors (HW)\n0.96\nTable J3D11i Conductance and radiation factors: climate zone 3\nType of factor\nFactor\nBedroom conduction weighting factor (BC)\n0.42\nRoom type multiplier (for bedroom and unconditioned areas) (RW)\n1.00\nBedroom solar heat gain weighting factor (BSW)\n1.28\nFloor factor for tiled or vinyl covered floors (HW)\n1.02\nFloor factor for other than tiled or vinyl covered floors (HW)\n0.97\nTable J3D11j Conductance and radiation factors: climate zone 4\nType of factor\nFactor\nBedroom conduction weighting factor (BC)\n0.70\nRoom type multiplier (for bedroom and unconditioned areas) (RW)\n1.00\nBedroom solar heat gain weighting factor (BSW)\n0.60\nFloor factor for tiled or vinyl covered floors (HW)\n1.04\nFloor factor for other than tiled or vinyl covered floors (HW)\n0.92\nTable J3D11k Conductance and radiation factors: climate zone 5\nType of factor\nFactor\nBedroom conduction weighting factor (BC)\n0.63\nRoom type multiplier (for bedroom and unconditioned areas) (RW)\n1.10\nBedroom solar heat gain weighting factor (BSW)\n0.81\nFloor factor for tiled or vinyl covered floors (HW)\n1.03\nFloor factor for other than tiled or vinyl covered floors (HW)\n0.93\nTable J3D11l Conductance and radiation factors: climate zone 6\nType of factor\nFactor\nBedroom conduction weighting factor (BC)\n0.81\nRoom type multiplier (for bedroom and unconditioned areas) (RW)\n1.00\nBedroom solar hea","g":"/ncc/j3d11"},{"c":"Table J3D12a","t":"Constant for Solar Heat Gain (CSHGC) — climate zones 1 to 7","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_be0ae543-86f7-44d9-b94c-650c8bd9638d","x":"% Ventilation opening area per m2 | Climate zone 1 | Climate zone 2 | Climate zone 3 | Climate zone 4 | Climate zone 5 | Climate zone 6 | Climate zone 7\n5% to <10% | 0.0191 | 0.0245 | 0.0547 | 0.0506 | 0.0674 | 0.1472 | 0.0930\n10% to <15% | 0.0237 | 0.0532 | 0.0745 | 0.0946 | 0.1111 | 0.2969 | 0.2405\n15% to <20% | 0.0294 | 0.0700 | 0.0861 | 0.1203 | 0.1367 | 0.3845 | 0.3267\n20% to 90% | 0.0364 | 0.0819 | 0.0943 | 0.1385 | 0.1548 | 0.4466 | 0.3879\nTable Notes\nThe ventilation opening area is the total area of each ventilation opening divided by the floor area of the storey, including any mezzanine.\nNo window can have a design ventilation opening greater than 90% because the window frame will always obstruct some area of the opening.\nInterpolation is allowed for values between those shown.","tb":"J3D12","g":"/ncc/table-j3d12a"},{"c":"Table J3D12b","t":"Orientation sector summer exposure factor (Es) — climate zone 1","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_5ab38396-defd-4053-b040-d3c9b0b76c1b","x":"P/H | North | North east | East | South east | South | South west | West | North west\n0.00 | 0.62 | 0.76 | 0.79 | 0.75 | 0.52 | 0.89 | 1.06 | 0.85\n0.05 | 0.52 | 0.67 | 0.73 | 0.68 | 0.45 | 0.82 | 0.98 | 0.75\n0.10 | 0.49 | 0.61 | 0.68 | 0.65 | 0.41 | 0.76 | 0.92 | 0.69\n0.20 | 0.44 | 0.53 | 0.62 | 0.57 | 0.33 | 0.66 | 0.80 | 0.60\n0.40 | 0.36 | 0.41 | 0.48 | 0.42 | 0.25 | 0.53 | 0.66 | 0.47\n0.60 | 0.30 | 0.33 | 0.40 | 0.36 | 0.20 | 0.42 | 0.53 | 0.38\n0.80 | 0.26 | 0.28 | 0.32 | 0.28 | 0.18 | 0.36 | 0.46 | 0.32\n1.00 | 0.23 | 0.23 | 0.27 | 0.25 | 0.15 | 0.30 | 0.38 | 0.28\n1.20 | 0.21 | 0.21 | 0.23 | 0.20 | 0.13 | 0.27 | 0.34 | 0.26\n1.40 | 0.20 | 0.19 | 0.20 | 0.18 | 0.13 | 0.22 | 0.30 | 0.22\n1.60 | 0.18 | 0.16 | 0.17 | 0.16 | 0.11 | 0.20 | 0.27 | 0.21\n1.80 | 0.15 | 0.16 | 0.16 | 0.13 | 0.10 | 0.20 | 0.24 | 0.18\n2.00 | 0.14 | 0.15 | 0.14 | 0.13 | 0.10 | 0.17 | 0.22 | 0.17","tb":"J3D12","g":"/ncc/table-j3d12b"},{"c":"Table J3D12c","t":"Orientation sector summer exposure factor (Es) — climate zone 2","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_0dded92e-2d0a-4f81-aca6-9f969ffdbbd4","x":"P/H | North | North east | East | South east | South | South west | West | North west\n0.00 | 0.65 | 1.16 | 1.59 | 1.20 | 0.73 | 1.30 | 1.77 | 1.23\n0.05 | 0.54 | 1.01 | 1.43 | 1.06 | 0.61 | 1.18 | 1.62 | 1.10\n0.10 | 0.50 | 0.94 | 1.35 | 0.99 | 0.58 | 1.10 | 1.50 | 1.00\n0.20 | 0.42 | 0.81 | 1.20 | 0.88 | 0.51 | 0.98 | 1.32 | 0.87\n0.40 | 0.35 | 0.62 | 0.95 | 0.70 | 0.40 | 0.78 | 1.10 | 0.67\n0.60 | 0.30 | 0.48 | 0.78 | 0.57 | 0.33 | 0.64 | 0.88 | 0.50\n0.80 | 0.26 | 0.41 | 0.65 | 0.47 | 0.29 | 0.54 | 0.77 | 0.43\n1.00 | 0.23 | 0.33 | 0.56 | 0.40 | 0.24 | 0.47 | 0.62 | 0.36\n1.20 | 0.21 | 0.30 | 0.46 | 0.35 | 0.22 | 0.40 | 0.54 | 0.31\n1.40 | 0.19 | 0.26 | 0.42 | 0.32 | 0.21 | 0.35 | 0.48 | 0.27\n1.60 | 0.17 | 0.25 | 0.36 | 0.29 | 0.19 | 0.31 | 0.41 | 0.24\n1.80 | 0.15 | 0.22 | 0.31 | 0.25 | 0.17 | 0.30 | 0.37 | 0.22\n2.00 | 0.15 | 0.21 | 0.29 | 0.24 | 0.16 | 0.26 | 0.36 | 0.21","tb":"J3D12","g":"/ncc/table-j3d12c"},{"c":"Table J3D12d","t":"Orientation sector summer exposure factor (Es) — climate zone 3","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_0f71607e-3f73-4ce9-8d86-88a1809c5cc9","x":"P/H | North | North east | East | South east | South | South west | West | North west\n0.00 | 0.80 | 1.26 | 1.41 | 1.38 | 0.89 | 1.33 | 1.29 | 1.20\n0.05 | 0.67 | 1.14 | 1.31 | 1.26 | 0.77 | 1.21 | 1.20 | 1.07\n0.10 | 0.63 | 1.03 | 1.24 | 1.19 | 0.73 | 1.14 | 1.13 | 0.99\n0.20 | 0.54 | 0.88 | 1.09 | 1.05 | 0.62 | 1.00 | 1.01 | 0.87\n0.40 | 0.46 | 0.68 | 0.87 | 0.83 | 0.51 | 0.83 | 0.80 | 0.67\n0.60 | 0.40 | 0.52 | 0.73 | 0.68 | 0.42 | 0.66 | 0.67 | 0.52\n0.80 | 0.34 | 0.42 | 0.58 | 0.55 | 0.36 | 0.58 | 0.57 | 0.42\n1.00 | 0.29 | 0.35 | 0.50 | 0.47 | 0.32 | 0.49 | 0.50 | 0.35\n1.20 | 0.27 | 0.31 | 0.42 | 0.40 | 0.28 | 0.43 | 0.41 | 0.31\n1.40 | 0.24 | 0.27 | 0.35 | 0.36 | 0.27 | 0.37 | 0.39 | 0.27\n1.60 | 0.24 | 0.24 | 0.33 | 0.32 | 0.22 | 0.36 | 0.33 | 0.25\n1.80 | 0.21 | 0.23 | 0.30 | 0.28 | 0.22 | 0.32 | 0.31 | 0.23\n2.00 | 0.21 | 0.22 | 0.25 | 0.28 | 0.20 | 0.28 | 0.26 | 0.20","tb":"J3D12","g":"/ncc/table-j3d12d"},{"c":"Table J3D12e","t":"Orientation sector summer exposure factor (Es) — climate zone 4","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_5916071a-4174-48fe-bdcc-d15910599482","x":"P/H | North | North east | East | South east | South | South west | West | North west\n0.00 | 0.79 | 1.13 | 1.12 | 1.05 | 0.68 | 1.14 | 1.44 | 1.23\n0.05 | 0.67 | 1.05 | 1.05 | 0.97 | 0.59 | 1.05 | 1.34 | 1.12\n0.10 | 0.62 | 0.95 | 0.99 | 0.91 | 0.55 | 0.98 | 1.29 | 1.03\n0.20 | 0.47 | 0.83 | 0.90 | 0.82 | 0.49 | 0.87 | 1.16 | 0.89\n0.40 | 0.33 | 0.63 | 0.74 | 0.67 | 0.41 | 0.71 | 0.94 | 0.68\n0.60 | 0.30 | 0.48 | 0.59 | 0.56 | 0.35 | 0.61 | 0.79 | 0.50\n0.80 | 0.26 | 0.36 | 0.50 | 0.49 | 0.30 | 0.52 | 0.65 | 0.40\n1.00 | 0.22 | 0.29 | 0.44 | 0.42 | 0.26 | 0.45 | 0.56 | 0.33\n1.20 | 0.21 | 0.25 | 0.37 | 0.37 | 0.24 | 0.40 | 0.50 | 0.28\n1.40 | 0.18 | 0.22 | 0.31 | 0.34 | 0.20 | 0.38 | 0.42 | 0.23\n1.60 | 0.18 | 0.19 | 0.30 | 0.30 | 0.19 | 0.33 | 0.36 | 0.22\n1.80 | 0.15 | 0.17 | 0.26 | 0.27 | 0.17 | 0.29 | 0.35 | 0.19\n2.00 | 0.14 | 0.16 | 0.22 | 0.23 | 0.17 | 0.28 | 0.29 | 0.18","tb":"J3D12","g":"/ncc/table-j3d12e"},{"c":"Table J3D12f","t":"Orientation sector summer exposure factor (Es) — climate zone 5","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_93ebff14-bb42-4481-8704-434bbedad862","x":"P/H | North | North east | East | South east | South | South west | West | North west\n0.00 | 0.82 | 1.20 | 1.31 | 1.06 | 0.82 | 1.04 | 1.30 | 1.16\n0.05 | 0.69 | 1.06 | 1.18 | 0.94 | 0.68 | 0.92 | 1.19 | 1.04\n0.10 | 0.63 | 0.97 | 1.11 | 0.87 | 0.65 | 0.86 | 1.11 | 0.94\n0.20 | 0.51 | 0.84 | 0.98 | 0.77 | 0.58 | 0.76 | 0.99 | 0.83\n0.40 | 0.39 | 0.64 | 0.78 | 0.63 | 0.46 | 0.62 | 0.81 | 0.62\n0.60 | 0.35 | 0.51 | 0.64 | 0.52 | 0.40 | 0.51 | 0.65 | 0.48\n0.80 | 0.30 | 0.41 | 0.55 | 0.44 | 0.34 | 0.43 | 0.52 | 0.40\n1.00 | 0.26 | 0.34 | 0.46 | 0.37 | 0.30 | 0.37 | 0.46 | 0.31\n1.20 | 0.24 | 0.29 | 0.40 | 0.33 | 0.26 | 0.33 | 0.40 | 0.27\n1.40 | 0.21 | 0.25 | 0.35 | 0.30 | 0.24 | 0.29 | 0.34 | 0.24\n1.60 | 0.20 | 0.24 | 0.32 | 0.25 | 0.22 | 0.27 | 0.30 | 0.21\n1.80 | 0.18 | 0.22 | 0.28 | 0.23 | 0.20 | 0.23 | 0.27 | 0.20\n2.00 | 0.17 | 0.19 | 0.26 | 0.23 | 0.19 | 0.21 | 0.25 | 0.19","tb":"J3D12","g":"/ncc/table-j3d12f"},{"c":"Table J3D12g","t":"Orientation sector summer exposure factor (Es) — climate zone 6","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_faf591f7-2c27-4347-a3db-35898d15ff6f","x":"P/H | North | North east | East | South east | South | South west | West | North west\n0.00 | 2.18 | 2.75 | 2.88 | 2.22 | 1.59 | 2.46 | 2.91 | 2.90\n0.05 | 1.85 | 2.47 | 2.63 | 1.99 | 1.35 | 2.25 | 2.70 | 2.64\n0.10 | 1.69 | 2.30 | 2.48 | 1.89 | 1.27 | 2.13 | 2.60 | 2.43\n0.20 | 1.35 | 1.96 | 2.20 | 1.66 | 1.14 | 1.92 | 2.33 | 2.13\n0.40 | 0.94 | 1.48 | 1.78 | 1.38 | 0.94 | 1.57 | 1.87 | 1.61\n0.60 | 0.78 | 1.10 | 1.53 | 1.15 | 0.81 | 1.36 | 1.58 | 1.19\n0.80 | 0.68 | 0.89 | 1.25 | 0.97 | 0.68 | 1.17 | 1.37 | 0.94\n1.00 | 0.57 | 0.74 | 1.05 | 0.82 | 0.60 | 0.98 | 1.16 | 0.84\n1.20 | 0.52 | 0.61 | 0.93 | 0.74 | 0.60 | 0.91 | 1.00 | 0.68\n1.40 | 0.47 | 0.56 | 0.80 | 0.66 | 0.49 | 0.80 | 0.87 | 0.61\n1.60 | 0.42 | 0.48 | 0.70 | 0.61 | 0.47 | 0.73 | 0.79 | 0.49\n1.80 | 0.39 | 0.46 | 0.65 | 0.56 | 0.44 | 0.66 | 0.71 | 0.47\n2.00 | 0.36 | 0.43 | 0.60 | 0.54 | 0.44 | 0.61 | 0.64 | 0.40","tb":"J3D12","g":"/ncc/table-j3d12g"},{"c":"Table J3D12h","t":"Orientation sector summer exposure factor (Es) — climate zone 7","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_3f479dd9-86d1-49fd-84d6-40fa8a682a9c","x":"P/H | North | North east | East | South east | South | South west | West | North west\n0.00 | 0.89 | 1.06 | 1.06 | 0.93 | 0.70 | 0.91 | 1.06 | 1.07\n0.05 | 0.77 | 0.95 | 0.97 | 0.82 | 0.59 | 0.81 | 0.97 | 0.97\n0.10 | 0.71 | 0.88 | 0.92 | 0.79 | 0.56 | 0.76 | 0.92 | 0.89\n0.20 | 0.58 | 0.77 | 0.82 | 0.69 | 0.50 | 0.68 | 0.81 | 0.78\n0.40 | 0.37 | 0.59 | 0.67 | 0.57 | 0.42 | 0.55 | 0.66 | 0.58\n0.60 | 0.30 | 0.46 | 0.57 | 0.50 | 0.36 | 0.47 | 0.56 | 0.46\n0.80 | 0.26 | 0.36 | 0.48 | 0.44 | 0.31 | 0.41 | 0.47 | 0.36\n1.00 | 0.23 | 0.30 | 0.42 | 0.37 | 0.28 | 0.35 | 0.39 | 0.29\n1.20 | 0.20 | 0.25 | 0.36 | 0.34 | 0.25 | 0.31 | 0.34 | 0.25\n1.40 | 0.18 | 0.21 | 0.32 | 0.30 | 0.23 | 0.28 | 0.29 | 0.22\n1.60 | 0.17 | 0.19 | 0.29 | 0.27 | 0.22 | 0.26 | 0.28 | 0.19\n1.80 | 0.16 | 0.18 | 0.25 | 0.24 | 0.20 | 0.24 | 0.24 | 0.17\n2.00 | 0.15 | 0.17 | 0.24 | 0.23 | 0.20 | 0.21 | 0.22 | 0.16","tb":"J3D12","g":"/ncc/table-j3d12h"},{"c":"Table J3D12i","t":"Conductance factors — climate zone 1","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_37ca6955-d86a-444f-bab1-9b9079d3bc65","x":"Factor | Value\nRoom type multiplier (for bedroom and unconditioned areas) (RS) | 0.32\nFrame solar absorptance multiplier Frame SA = 0.3 up to 0.4 (FS) | 0.83\nFrame solar absorptance multiplier Frame SA = 0.4 up to 0.5 (FS) | 1.00\nFrame solar absorptance multiplier Frame SA = 0.5 or more (FS) | 1.20\nFloor factor for tiled or vinyl covered floors (HS) | 1.00\nFloor factor for other than tiled or vinyl covered floors (HS) | 1.00","tb":"J3D12","g":"/ncc/table-j3d12i"},{"c":"Table J3D12j","t":"Conductance factors — climate zones 2 to 7","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_e4c7db3b-80ed-4732-8047-5c53f77a73f9","x":"Type of factor | Climate zone 2 | Climate zone 3 | Climate zone 4 | Climate zone 5 | Climate zone 6 | Climate zone 7\nRoom type multiplier (for bedroom and unconditioned areas) (RS) | 0.40 | 0.56 | 0.71 | 0.91 | 0.87 | 1.11\nFrame solar absorptance multiplier (for metal frame windows) (FS) SA ≤ 0.40 | 1.00 | 0.89 | 0.87 | 0.85 | 0.74 | 0.86\nFrame solar absorptance multiplier (for metal frame windows) (FS) SA > 0.40 to < 0.68 | 1.06 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00\nFrame solar absorptance multiplier (for metal frame windows) (FS) SA ≥ 0.68 | 1.22 | 1.18 | 1.22 | 1.24 | 1.22 | 1.32\nFloor factor for tiled or vinyl covered floors (HS) | 1.06 | 1.06 | 1.13 | 1.13 | 1.04 | 1.21\nFloor factor for other than tiled or vinyl covered floors (HS) | 0.97 | 0.97 | 0.94 | 0.94 | 0.94 | 0.90\nTable Notes\nInterpolation is allowed for values between those shown.","tb":"J3D12","g":"/ncc/table-j3d12j"},{"c":"J3D12","t":"External summer glazing of a Class 4 part of a building","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#J3D12","x":"(1) In climate zones 1 to 7, the aggregate solar heat gain of the glazing in each storey, including any mezzanine, of a Class 4 part of a building must—\nnot exceed the allowance resulting from multiplying the floor area of the storey, including any mezzanine, measured within the enclosing walls, by the constant CSHGC obtained from Table J3D12a; and\nbe calculated in accordance with the following formula:\n[formula] (2) In the formula at (1)(b)—\n[formula] = the area of each glazing element; and\n[formula] = the Total System SHGC for each glazing element, not exceeding 0.7; and\n[formula] = the summer exposure factor for each glazing element obtained from Table J3D12b, J3D12c, J3D12d, J3D12e, J3D12f, J3D12g or J3D12h.\n[formula] = the factor obtained from Table J3D12i or Table J3D12j for each glazing element located in a bedroom or room which is not a conditioned space; and\n[formula] = the frame factor obtained from Table J3D12i or Table J3D12j for glazing element; and\n[formula] = the floor factor obtained from Table J3D12i or Table J3D12j for each glazing element.\n(3) For the purpose of J3D12—\norientation sectors must be determined in accordance with Figure 13.3.2a of the ABCB Housing Provisions; and\nP/H must be determined in accordance with Figure S37C7a; and\nfor P/H between those shown in Tables J3D12b, J3D12c, J3D12d, J3D12e, J3D12f, J3D12g, J3D12h, J3D12i and J3D12j, either use the next highest P/H or interpolate.\nTable J3D12a Constant for Solar Heat Gain (CSHGC) — climate zones 1 to 7\n% Ventilation opening area per m2\nClimate zone 1\nClimate zone 2\nClimate zone 3\nClimate zone 4\nClimate zone 5\nClimate zone 6\nClimate zone 7\n5% to <10%\n0.0191\n0.0245\n0.0547\n0.0506\n0.0674\n0.1472\n0.0930\n10% to <15%\n0.0237\n0.0532\n0.0745\n0.0946\n0.1111\n0.2969\n0.2405\n15% to <20%\n0.0294\n0.0700\n0.0861\n0.1203\n0.1367\n0.3845\n0.3267\n20% to 90%\n0.0364\n0.0819\n0.0943\n0.1385\n0.1548\n0.4466\n0.3879\nTable Notes\nThe ventilation opening area is the total area of each ventilation opening divided by the floor area of the storey, including any mezzanine.\nNo window can have a design ventilation opening greater than 90% because the window frame will always obstruct some area of the opening.\nInterpolation is allowed for values between those shown.\nTable J3D12b Orientation sector summer exposure factor (Es) — climate zone 1\nP/H\nNorth\nNorth east\nEast\nSouth east\nSouth\nSouth west\nWest\nNorth west\n0.00\n0.62\n0.76\n0.79\n0.75\n0.52\n0.89\n1.06\n0.85\n0.05\n0.52\n0.67\n0.73\n0.68\n0.45\n0.82\n0.98\n0.75\n0.10\n0.49\n0.61\n0.68\n0.65\n0.41\n0.76\n0.92\n0.69\n0.20\n0.44\n0.53\n0.62\n0.57\n0.33\n0.66\n0.80\n0.60\n0.40\n0.36\n0.41\n0.48\n0.42\n0.25\n0.53\n0.66\n0.47\n0.60\n0.30\n0.33\n0.40\n0.36\n0.20\n0.42\n0.53\n0.38\n0.80\n0.26\n0.28\n0.32\n0.28\n0.18\n0.36\n0.46\n0.32\n1.00\n0.23\n0.23\n0.27\n0.25\n0.15\n0.30\n0.38\n0.28\n1.20\n0.21\n0.21\n0.23\n0.20\n0.13\n0.27\n0.34\n0.26\n1.40\n0.20\n0.19\n0.20\n0.18\n0.13\n0.22\n0.30\n0.22\n1.60\n0.18\n0.16\n0.17\n0.16\n0.11\n0.20\n0.27\n0.21\n1.80\n0.15\n0.16\n0.16\n0.13\n0.10\n0.20\n0.24\n0.18\n2.00\n0.14\n0.15\n0.14\n0.13\n0.10\n0.17\n0.22\n0.17\nTable J3D12c Orientation sector summer exposure factor (Es) — climate zone 2\nP/H\nNorth\nNorth east\nEast\nSouth east\nSouth\nSouth west\nWest\nNorth west\n0.00\n0.65\n1.16\n1.59\n1.20\n0.73\n1.30\n1.77\n1.23\n0.05\n0.54\n1.01\n1.43\n1.06\n0.61\n1.18\n1.62\n1.10\n0.10\n0.50\n0.94\n1.35\n0.99\n0.58\n1.10\n1.50\n1.00\n0.20\n0.42\n0.81\n1.20\n0.88\n0.51\n0.98\n1.32\n0.87\n0.40\n0.35\n0.62\n0.95\n0.70\n0.40\n0.78\n1.10\n0.67\n0.60\n0.30\n0.48\n0.78\n0.57\n0.33\n0.64\n0.88\n0.50\n0.80\n0.26\n0.41\n0.65\n0.47\n0.29\n0.54\n0.77\n0.43\n1.00\n0.23\n0.33\n0.56\n0.40\n0.24\n0.47\n0.62\n0.36\n1.20\n0.21\n0.30\n0.46\n0.35\n0.22\n0.40\n0.54\n0.31\n1.40\n0.19\n0.26\n0.42\n0.32\n0.21\n0.35\n0.48\n0.27\n1.60\n0.17\n0.25\n0.36\n0.29\n0.19\n0.31\n0.41\n0.24\n1.80\n0.15\n0.22\n0.31\n0.25\n0.17\n0.30\n0.37\n0.22\n2.00\n0.15\n0.21\n0.29\n0.24\n0.16\n0.26\n0.36\n0.21\nTable J3D12d Orientation sector summer exposure factor (Es) — climate zone 3\nP/H\nNorth\nNorth east\nEast\nSouth east\nSouth\nSouth west\nWest\nNorth west\n0.00\n0.80\n1.26\n1.41\n1.38\n0.89\n1.33\n1.29\n1.20\n0.05\n0.67\n1.14\n1.31\n1.26\n0.77\n1.21\n1.20\n1.07\n0.10\n0.63\n1.03\n1.24\n1.19\n0.73\n1.14\n1.13\n0.99\n0.20\n0.54\n0.88\n1.09\n1.05\n0.62\n1.00\n1.01\n0.87\n0.40\n0.46\n0.68\n0.87\n0.83\n0.51\n0.83\n0.80\n0.67\n0.60\n0.40\n0.52\n0.73\n0.68\n0.42\n0.66\n0.67\n0.52\n0.80\n0.34\n0.42\n0.58\n0.55\n0.36\n0.58\n0.57\n0.42\n1.00\n0.29\n0.35\n0.50\n0.47\n0.32\n0.49\n0.50\n0.35\n1.20\n0.27\n0.31\n0.42\n0.40\n0.28\n0.43\n0.41\n0.31\n1.40\n0.24\n0.27\n0.35\n0.36\n0.27\n0.37\n0.39\n0.27\n1.60\n0.24\n0.24\n0.33\n0.32\n0.22\n0.36\n0.33\n0.25\n1.80\n0.21\n0.23\n0.30\n0.28\n0.22\n0.32\n0.31\n0.23\n2.00\n0.21\n0.22\n0.25\n0.28\n0.20\n0.28\n0.26\n0.20\nTable J3D12e Orientation sector summer exposure factor (Es) — climate zone 4\nP/H\nNorth\nNorth east\nEast\nSouth east\nSouth\nSouth west\nWest\nNorth west\n0.00\n0.79\n1.13\n1.12\n1.05\n0.68\n1.14\n1.44\n1.23\n0.05\n0.67\n1.05\n1.05\n0.97\n0.59\n1.05\n1.34\n1.12\n0.10\n0.62\n0.95\n0.99\n0.91\n0.55\n0.98\n1.29\n1.03\n0.20\n0.47\n0.83\n0.90\n0.82\n0.49\n0.87\n1.16\n0.89\n0.40\n0.33\n0.63\n0.74\n0.67\n0.41\n0.71\n0.94\n0.68\n0.60\n0.30\n0.48\n0.59\n0.56\n0.35\n0.61\n0.79\n0.50\n0.80\n0.26\n0.36\n0.50\n0.49\n0.30\n0.52\n0.65\n0.40\n1.00\n0.22\n0.29\n0.44\n0.42\n0.26\n0.45\n0.56\n0.33\n1.20\n0.21\n0.25\n0.37\n0.37\n0.24\n0.40\n0.50\n0.28\n1.40\n0.18\n0.22\n0.31\n0.34\n0.20\n0.38\n0.42\n0.23\n1.60\n0.18\n0.19\n0.30\n0.30\n0.19\n0.33\n0.36\n0.22\n1.80\n0.15\n0.17\n0.26\n0.27\n0.17\n0.29\n0.35\n0.19\n2.00\n0.14\n0.16\n0.22\n0.23\n0.17\n0.28\n0.29\n0.18\nTable J3D12f Orientation sector summer exposure factor (Es) — climate zone 5\nP/H\nNorth\nNorth east\nEast\nSouth east\nSouth\nSouth west\nWest\nNorth west\n0.00\n0.82\n1.20\n1.31\n1.06\n0.82\n1.04\n1.30\n1.16\n0.05\n0.69\n1.06\n1.18\n0.94\n0.68\n0.92\n1.19\n1.04\n0.10\n0.63\n0.97\n1.11\n0.87\n0.65\n0.86\n1.11\n0.94\n0.20\n0.51\n0.84\n0.98\n0.77\n0.58\n0.76\n0.99\n0.83\n0.40\n0.39\n0.64\n0.78\n0.63\n0.46\n0.62\n0.81\n0.62\n0.60\n0.35\n0.51\n0.64\n0.52\n0.40\n0.51\n0.65\n0.48\n0.80\n0.30\n0.41\n0.55\n0.44\n0.34\n0.43\n0.52\n0.40\n1.00\n0.26\n0.34\n0.46\n0.37\n0.30\n0.37\n0.46\n0.31\n1.20\n0.24\n0.29\n0.40\n0.33\n0.26\n0.33\n0.40\n0.27\n1.40\n0.21\n0.25\n0.35\n0.30\n0.24\n0.29\n0.34\n0.24\n1.60\n0.20\n0.24\n0.32\n0.25\n0.22\n0.27\n0.30\n0.21\n1.80\n0.18\n0.22\n0.28\n0.23\n0.20\n0.23\n0.27\n0.20\n2.00\n0.17\n0.19\n0.26\n0.23\n0.19\n0.21\n0.25\n0.19\nTable J3D12g Orientation sector summer exposure factor (Es) — climate zone 6\nP/H\nNorth\nNorth east\nEast\nSouth east\nSouth\nSouth west\nWest\nNorth west\n0.00\n2.18\n2.75\n2.88\n2.22\n1.59\n2.46\n2.91\n2.90\n0.05\n1.85\n2.47\n2.63\n1.99\n1.35\n2.25\n2.70\n2.64\n0.10\n1.69\n2.30\n2.48\n1.89\n1.27\n2.13\n2.60\n2.43\n0.20\n1.35\n1.96\n2.20\n1.66\n1.14\n1.92\n2.33\n2.13\n0.40\n0.94\n1.48\n1.78\n1.38\n0.94\n1.57\n1.87\n1.61\n0.60\n0.78\n1.10\n1.53\n1.15\n0.81\n1.36\n1.58\n1.19\n0.80\n0.68\n0.89\n1.25\n0.97\n0.68\n1.17\n1.37\n0.94\n1.00\n0.57\n0.74\n1.05\n0.82\n0.60\n0.98\n1.16\n0.84\n1.20\n0.52\n0.61\n0.93\n0.74\n0.60\n0.91\n1.00\n0.68\n1.40\n0.47\n0.56\n0.80\n0.66\n0.49\n0.80\n0.87\n0.61\n1.60\n0.42\n0.48\n0.70\n0.61\n0.47\n0.73\n0.79\n0.49\n1.80\n0.39\n0.46\n0.65\n0.56\n0.44\n0.66\n0.71\n0.47\n2.00\n0.36\n0.43\n0.60\n0.54\n0.44\n0.61\n0.64\n0.40\nTable J3D12h Orientation sector summer exposure factor (Es) — climate zone 7\nP/H\nNorth\nNorth east\nEast\nSouth east\nSouth\nSouth west\nWest\nNorth west\n0.00\n0.89\n1.06\n1.06\n0.93\n0.70\n0.91\n1.06\n1.07\n0.05\n0.77\n0.95\n0.97\n0.82\n0.59\n0.81\n0.97\n0.97\n0.10\n0.71\n0.88\n0.92\n0.79\n0.56\n0.76\n0.92\n0.89\n0.20\n0.58\n0.77\n0.82\n0.69\n0.50\n0.68\n0.81\n0.78\n0.40\n0.37\n0.59\n0.67\n0.57\n0.42\n0.55\n0.66\n0.58\n0.60\n0.30\n0.46\n0.57\n0.50\n0.36\n0.47\n0.56\n0.46\n0.80\n0.26\n0.36\n0.48\n0.44\n0.31\n0.41\n0.47\n0.36\n1.00\n0.23\n0.30\n0.42\n0.37\n0.28\n0.35\n0.39\n0.29\n1.20\n0.20\n0.25\n0.36\n0.34\n0.25\n0.31\n0.34\n0.25\n1.40\n0.18\n0.21\n0.32\n0.30\n0.23\n0.28\n0.29\n0.22\n1.60\n0.17\n0.19\n0.29\n0.27\n0.22\n0.26\n0.28\n0.19\n1.80\n0.16\n0.18\n0.25\n0.24\n0.20\n0.24\n0.24\n0.17\n2.00\n0.15\n0.17\n0.24\n0.23\n0.20\n0.21\n0.22\n0.16\nTable J3D12i Conductance factors — climate zone 1\nFactor\nValue\nRoom type multiplier (for bedroom and unconditioned areas) (RS)\n0.32\nFrame solar absorptance multiplier Frame SA = 0.3 up to 0.4 (FS)\n0.83\nFrame solar absorptance multiplier Frame SA = 0.4 up to 0.5 (FS)\n1.00\nFrame solar absorptance multiplier Frame SA = 0.5 or more (FS)\n1.20\nFloor factor for tiled or vinyl covered floors (HS)\n1.00\nFloor factor for other than tiled or vinyl covered floors (HS)\n1.00\nTable J3D12j Conductance factors — climate zones 2 to 7\nType of factor\nClimate zone 2\nClimate zone 3\nClimate zone 4\nClimate zone 5\nClimate zone 6\nClimate zone 7\nRoom type mul","g":"/ncc/j3d12"},{"c":"J3D13","t":"Shading of a Class 4 part of a building","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#J3D13","x":"Where shading is required to comply with J3D11 or J3D12, it must—\nbe provided by an external permanent projection, such as a verandah, balcony, fixed canopy, eaves, shading hood or carport, which—\nextends horizontally on both sides of the glazing for a distance greater than or equal to the projection distance P in Figure S37C7a; or\nprovide the equivalent shading to (i) with a reveal or the like; or\nbe provided by an external shading device, such as a shutter, blind, vertical or horizontal building screen with blades, battens or slats, which—\nis capable of restricting at least 80% of the summer solar radiation; and\nif adjustable, is readily operated either manually, mechanically or electronically by the building occupants.","g":"/ncc/j3d13"},{"c":"Table J3D14a","t":"Floor area adjustment factor for a Class 4 part of a building","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_2950f649-a2c2-4bc7-b386-18fbab767e99","x":"Total floor area m2 | Floor area factor | Total floor area m2 | Floor area factor | Total floor area m2 | Floor area factor | Total floor area m2 | Floor area factor\n< 50 | 0.0123 | 160–169 | 0.0097 | 280–289 | 0.0087 | 400–409 | 0.0080\n50–59 | 0.0119 | 170–179 | 0.0096 | 290–299 | 0.0086 | 410–419 | 0.0079\n60–69 | 0.0116 | 180–189 | 0.0095 | 300–309 | 0.0085 | 420–429 | 0.0079\n70–79 | 0.0113 | 190–199 | 0.0094 | 310–319 | 0.0085 | 430–439 | 0.0078\n80–89 | 0.0111 | 200–209 | 0.0093 | 320–329 | 0.0084 | 440–449 | 0.0078\n90–99 | 0.0108 | 210–219 | 0.0092 | 330–339 | 0.0083 | 450–459 | 0.0077\n100–109 | 0.0106 | 220–229 | 0.0091 | 340–349 | 0.0083 | 460–469 | 0.0077\n110–119 | 0.0105 | 230–239 | 0.0090 | 350–359 | 0.0082 | 470–479 | 0.0077\n120–129 | 0.0103 | 240–249 | 0.0090 | 360–369 | 0.0082 | 480–489 | 0.0076\n130–139 | 0.0101 | 250–259 | 0.0089 | 370–379 | 0.0081 | 490–499 | 0.0076\n140–149 | 0.0100 | 260–269 | 0.0088 | 380–389 | 0.0081 | 500 | 0.0075\n150–159 | 0.0099 | 270–279 | 0.0087 | 390–399 | 0.0080 | — | —\nTable Notes\nThe total floor area is measured within the inside face of the external walls of the sole-occupancy unit and includes any conditioned attached Class 10a building.\nWhere values fall between ranges given, the floor area must be rounded up to the nearest whole square metres of floor area.","tb":"J3D14","g":"/ncc/table-j3d14a"},{"c":"Table J3D14b","t":"Energy factor for a Class 4 part of a building","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_2682ff78-9378-4b3b-8b2a-48d213656050","x":"Climate zone | ACT | NSW | NT | QLD | SA | TAS | Vic | WA\n1 | — | — | 2.73 | 3.95 | — | — | — | 4.64\n2 | — | 1.88 | — | 2.54 | — | — | — | —\n3 | — | — | 1.76 | 3.52 | — | — | — | 4.10\n4 | — | 2.57 | — | — | 2.65 | — | 1.79 | 3.34\n5 | — | 2.50 | — | 3.26 | 2.56 | — | — | 3.36\n6 | — | 3.43 | — | — | 3.58 | — | 2.32 | 4.58\n7 | 3.66 | 3.32 | — | — | — | 4.41 | 2.32 | —\n8 | — | 5.70 | — | — | — | 5.60 | 4.02 | —","tb":"J3D14","g":"/ncc/table-j3d14b"},{"c":"Table J3D14c","t":"Heated water load factor for a Class 4 part of a building","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_cde189fe-8b57-41eb-8f6d-4c4a7d7a94c3","x":"Total floor area m2 | Load factor | Total floor area m2 | Load factor | Total floor area m2 | Load factor | Total floor area m2 | Load factor\n< 50 | 0.20 | 160 - 169 | 0.48 | 280 - 289 | 0.59 | 400 - 409 | 0.66\n50 - 59 | 0.22 | 170 - 179 | 0.49 | 290 - 299 | 0.60 | 410 - 419 | 0.67\n60 - 69 | 0.25 | 180 - 189 | 0.51 | 300 - 309 | 0.60 | 420 - 429 | 0.67\n70 - 79 | 0.28 | 190 - 199 | 0.52 | 310 - 319 | 0.61 | 430 - 439 | 0.68\n80 - 89 | 0.31 | 200 - 209 | 0.53 | 320 - 329 | 0.61 | 440 - 449 | 0.69\n90 - 99 | 0.34 | 210 - 219 | 0.54 | 330 - 339 | 0.62 | 450 - 459 | 0.69\n100 - 109 | 0.37 | 220 - 229 | 0.55 | 340 - 349 | 0.62 | 460 - 469 | 0.70\n110 - 119 | 0.39 | 230 - 239 | 0.56 | 350 - 359 | 0.63 | 470 - 479 | 0.71\n120 - 129 | 0.41 | 240 - 249 | 0.56 | 360 - 369 | 0.63 | 480 - 489 | 0.72\n130 - 139 | 0.43 | 250 - 259 | 0.57 | 370 - 379 | 0.64 | 490 - 499 | 0.72\n140 - 149 | 0.45 | 260 - 269 | 0.58 | 380 - 389 | 0.65 | 500 | 0.73\n150 - 159 | 0.47 | 270 - 279 | 0.58 | 390 - 399 | 0.65 | — | —\nTable Notes\nThe total floor area is measured within the inside face of the external walls of the sole-occupancy unit and includes any conditioned attached Class 10a building.\nWhere values fall between ranges given, the floor area must be rounded up to the nearest whole square metres of floor area.","tb":"J3D14","g":"/ncc/table-j3d14c"},{"c":"Table J3D14d","t":"Energy factor (CP or CS) for a circulating pump serving a Class 4 part of a building","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_f61928c6-ee96-408b-9084-91f5bf87b151","x":"Climate zone | ACT | NSW | NT | QLD | SA | TAS | VIC | WA\n1 | — | — | 0.064 | 0.115 | — | — | — | 0.148\n2 | — | 0.131 | — | 0.113 | — | — | — | —\n3 | — | — | 0.06 | 0.104 | — | — | — | 0.139\n4 | — | 0.134 | — | — | 0.138 | — | 0.112 | 0.153\n5 | — | 0.15 | — | 0.129 | 0.147 | — | — | 0.153\n6 | — | 0.161 | — | — | 0.167 | — | 0.135 | 0.184\n7 | 0.131 | 0.173 | — | — | — | 0.146 | 0.145 | —\n8 | — | 0.155 | — | — | — | 0.131 | 0.13 | —\nTable Notes\nIf no primary circulating pump is present, then .\nIf no secondary circulating pump is present, then .","tb":"J3D14","g":"/ncc/table-j3d14d"},{"c":"Table J3D14e","t":"Water heater type to be applied when using the ABCB Standard for Whole-of-Home Efficiency Factors for a Class 4 part of a building","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#_a686dd15-b929-4918-bc7d-421d478a15b1","x":"System Number | Type of centralised heated water system | Equivalent heated water system\n1 | Single electric storage (boiler) | Electric storage (standard or off-peak)\n2 | Manifolded electric storage | Electric storage (standard or off-peak)\n3 | Manifolded electric instantaneous - no storage | Electric storage (standard or off-peak)\n4 | Manifolded electric instantaneous - with storage | Electric storage (standard or off-peak)\n5 | Air-sourced heat pump - with storage | Heat pump (standard or off-peak)\n6 | Manifolded air source heat pumps - with storage | Heat pump (standard or off-peak)\n7 | Electric boosted solar - with storage | Solar electric (standard)\n8 | Manifolded electric boosted solar - with storage | Solar electric (standard)\n9 | Heat pump boosted solar - with storage | Solar electric (standard) or heat pump (standard or off-peak)\n10 | Manifolded heat pump boosted solar - with storage | Solar electric (standard) or heat pump (standard or off-peak)\n11 | Gas storage (boiler) | Gas storage\n12 | Manifolded gas storage | Gas storage\n13 | Manifolded gas instantaneous - no storage | Gas instantaneous\n14 | Manifolded gas instantaneous - with storage | Gas storage\n15 | Gas boosted solar with storage | Solar gas\n16 | Manifolded gas boosted solar with storage | Solar gas\n17 | Instantaneous gas boosted solar - with storage | Solar gas\n18 | Manifold instantaneous gas boosted solar - with storage | Solar gas\n19 | Gas boosted air sourced heat pump | Heat pump (standard)\n20 | All other electrically heated types of central domestic hot water systems | Electric storage (standard or off-peak)\n21 | All other gas heated types of central domestic hot water systems | Gas storage\nTable Notes\nIf the electricity tariff of the centralised heated water system is unknown, select “standard” from the ABCB Standard for Whole-of-Home Efficiency Factors.","tb":"J3D14","g":"/ncc/table-j3d14e"},{"c":"J3D14","t":"Net equivalent energy usage of a Class 4 part of a building","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#J3D14","x":"(1) The net equivalent energy usage of a Class 4 part of a building must not exceed the allowance determined in accordance with the following formula:\n[formula] , where—\n[formula] = the floor area factor obtained from multiplying the total floor area by the adjustment factor in Table J3D14a; and\n[formula] = the energy factor obtained from Table J3D14b.\n(2) For the purposes of (1), the net equivalent energy usage must be calculated—\nwhere the Class 4 part of a building is served by a dedicated heated water system, in accordance with (3); and\nwhere the Class 4 part of a building is served by a centralised heated water system, in accordance with (4).\n(3)\nThe net equivalent energy usage of a Class 4 part of a building served by a dedicated heated water system must be determined in accordance with the following formula: [formula] , where—\n[formula] = the floor area factor obtained from multiplying the total floor area by the adjustment factor in Table J3D14a; and\n[formula] = the main space conditioning and main water heater efficiency factor obtained from the ABCB Standard for Whole-of-Home Efficiency Factors; and\n[formula] = the swimming pool pump energy usage in (5); and\n[formula] = the spa pump energy in (6); and\n[formula] = the installed capacity of a on-site photovoltaics apportioned to the Class 4 part of a building (kW); and\n(4)\nThe net equivalent energy usage of a Class 4 part of a building served by a centralised heated water system must be determined in accordance with the following formula: [formula] , where—\n[formula] = the floor area factor obtained from multiplying the total floor area by the adjustment factor in Table J3D14a; and\n[formula] = subject to (7), the main space conditioning and main water heater efficiency factor obtained from the ABCB Standard for Whole-of-Home Efficiency Factors; and\n[formula] = the swimming pool pump energy usage in (5); and\n[formula] = the spa pump energy usage in (6); and\n[formula] = the centralised heated water system circulating pump energy usage in (8); and\n[formula] = the installed capacity, in kW, of on-site photovoltaics apportioned to the Class 4 part of a building; and\n[formula] = the installed capacity, in kW, of on-site photovoltaics that directly offsets the energy consumption of circulating pumps for a centralised heated water system serving a Class 4 part of a building, where—\nthis value does not exceed circulating pump energy usage [formula] ; and\nthe on-site solar photovoltaics are directly connected to the same electrical supply as common area equipment in the building, including the circulating pumps.\n(5)\nThe swimming pool pump energy usage (EP) for a swimming pool dedicated solely to the Class 4 part of a building must be determined in accordance with the following formula: [formula] , where—\n[formula] = the swimming pool pump energy usage; and\n[formula] = the volume of the swimming pool to the nearest 1000 litres; and\n[formula] = the swimming pool pump factor in Table 13.6.2c of the ABCB Housing Provisions.\n(6)\nThe spa pump energy usage (ES) must be determined in accordance with the following formula: [formula] ,where—\n[formula] = the spa pump energy usage; and\n[formula] = the volume of the spa to the nearest 100 litres; and\n[formula] = the spa pump factor in Table 13.6.2d of the ABCB Housing Provisions.\n(7) The main space conditioning and main water heater efficiency factor for a Class 4 part of a building served by a centralised heated water system must be determined in accordance with the following—\nfor other than a solar boosted centralised heated water system, the equivalent water heater used to the determine the efficiency factor in the ABCB Standard for Whole-of-Home Efficiency Factors must be determined in accordance with Table J3D14e; and\nfor a solar boosted centralised heated water system, the efficiency factors must be determined in accordance with the following formula: [formula] , where—\n[formula] = the main space conditioning and main water heater efficiency factor; and\n[formula] = the efficiency factor obtained from the ABCB Standard for Whole-of-Home Efficiency Factors using the equivalent water heater in Table J3D14e; and\n[formula] = the efficiency factor obtained from the ABCB Standard for Whole-of-Home Efficiency Factors for—\nwhere the solar boosted centralised heated water system uses heat pump type heating as the auxiliary heating source, a heat pump (standard) water heater; and\nwhere the solar boosted centralised heated water system uses gas type heating as the auxiliary heating source, a gas storage water heater; and\nfor all other types of solar boosted centralised heated water systems, an electric storage (standard) water heater; and\n[formula] = the solar percentage factor determined in accordance with the following formula: [formula] , where—\n[formula] = the solar percentage factor; and\n[formula] = the total area in m2 of all solar thermal collectors connected to the heated water system; and\n[formula] = the total floor area in m2 of all sole-occupancy units served by the heated water system.\n[formula] = the non-solar percentage factor determined in accordance with the following formula: [formula] , where—\n[formula] = the non-solar percentage factor; and\n[formula] = the solar percentage factor in (iv); and\nwhere the main space conditioning and main water heater efficiency factor for the heat pump [formula] is less than that of the solar boosted system [formula] then [formula] must be set to 0 and [formula] to 1; and\n[formula] cannot be greater than 1.0.\n(8)\nThe circulating pump energy usage [formula] must be determined in accordance with the following formula: [formula] , where—\n[formula] = the circulating pump energy usage; and\n[formula] = heated water load factor obtained from Table J3D14c; and\n[formula] = the primary circulating pump energy factor obtained from Table J3D14d; and\n[formula] = the secondary circulating pump energy factor obtained from Table J3D14d; and\n[formula] = the factor for the number of sole-occupancy units served determined in accordance with the following formula: [formula] = 0.6 + (number of sole-occupancy units served - 100) x 0.00133; and\n[formula] = cannot be greater than 1.0.\nTable J3D14a Floor area adjustment factor for a Class 4 part of a building\nTotal floor area m2\nFloor area factor\nTotal floor area m2\nFloor area factor\nTotal floor area m2\nFloor area factor\nTotal floor area m2\nFloor area factor\n< 50\n0.0123\n160–169\n0.0097\n280–289\n0.0087\n400–409\n0.0080\n50–59\n0.0119\n170–179\n0.0096\n290–299\n0.0086\n410–419\n0.0079\n60–69\n0.0116\n180–189\n0.0095\n300–309\n0.0085\n420–429\n0.0079\n70–79\n0.0113\n190–199\n0.0094\n310–319\n0.0085\n430–439\n0.0078\n80–89\n0.0111\n200–209\n0.0093\n320–329\n0.0084\n440–449\n0.0078\n90–99\n0.0108\n210–219\n0.0092\n330–339\n0.0083\n450–459\n0.0077\n100–109\n0.0106\n220–229\n0.0091\n340–349\n0.0083\n460–469\n0.0077\n110–119\n0.0105\n230–239\n0.0090\n350–359\n0.0082\n470–479\n0.0077\n120–129\n0.0103\n240–249\n0.0090\n360–369\n0.0082\n480–489\n0.0076\n130–139\n0.0101\n250–259\n0.0089\n370–379\n0.0081\n490–499\n0.0076\n140–149\n0.0100\n260–269\n0.0088\n380–389\n0.0081\n500\n0.0075\n150–159\n0.0099\n270–279\n0.0087\n390–399\n0.0080\n—\n—\nTable Notes\nThe total floor area is measured within the inside face of the external walls of the sole-occupancy unit and includes any conditioned attached Class 10a building.\nWhere values fall between ranges given, the floor area must be rounded up to the nearest whole square metres of floor area.\nTable J3D14b Energy factor for a Class 4 part of a building\nClimate zone\nACT\nNSW\nNT\nQLD\nSA\nTAS\nVic\nWA\n1\n—\n—\n2.73\n3.95\n—\n—\n—\n4.64\n2\n—\n1.88\n—\n2.54\n—\n—\n—\n—\n3\n—\n—\n1.76\n3.52\n—\n—\n—\n4.10\n4\n—\n2.57\n—\n—\n2.65\n—\n1.79\n3.34\n5\n—\n2.50\n—\n3.26\n2.56\n—\n—\n3.36\n6\n—\n3.43\n—\n—\n3.58\n—\n2.32\n4.58\n7\n3.66\n3.32\n—\n—\n—\n4.41\n2.32\n—\n8\n—\n5.70\n—\n—\n—\n5.60\n4.02\n—\nTable J3D14c Heated water load factor for a Class 4 part of a building\nTotal floor area m2\nLoad factor\nTotal floor area m2\nLoad factor\nTotal floor area m2\nLoad factor\nTotal floor area m2\nLoad factor\n< 50\n0.20\n160 - 169\n0.48\n280 - 289\n0.59\n400 - 409","g":"/ncc/j3d14"},{"c":"J3D15","t":"Net equivalent energy usage for Class 4 part of building – home energy rating software","p":"Part J3 Elemental provisions for a Class 4 part of a building","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j3-elemental-provisions-class-4-part-building#J3D15","x":"A Class 4 part of a building must achieve a whole-of-home rating of not less than 50 using house energy rating software.","g":"/ncc/j3d15"},{"c":"J4D1","t":"Deemed-to-Satisfy Provisions","p":"Part J4 Building fabric","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j4-building-fabric#J4D1","x":"(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements J1P1 to J1P4 are satisfied by complying with—\nJ2D2; and\nJ3D2 to J3D15; and\nJ4D2 to J4D7; and\nJ5D2 to J5D8; and\nJ6D2 to J6D13; and\nJ7D2 to J7D9; and\nJ8D2 to J8D5; and\nJ9D2 to J9D5.\n(2) Where a Performance Solution is proposed, the relevant Performance Requirements must be determined in accordance with A2G2(3) and A2G4(3) as applicable.","g":"/ncc/j4d1","a19":["J1.0"]},{"c":"J4D2","t":"Application of Part","p":"Part J4 Building fabric","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j4-building-fabric#J4D2","x":"The Deemed-to-Satisfy Provisions of this Part apply to building elements forming the envelope of a Class 3 to 9 building other than J4D3(5), J4D4, J4D5, J4D6 and J4D7 which do not apply to a Class 4 part of a building.","g":"/ncc/j4d2","a19":["J1.1","NSW J(A)1.1"]},{"c":"J4D3","t":"Thermal construction — general","p":"Part J4 Building fabric","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j4-building-fabric#J4D3","x":"(1) Where required, insulation must comply with AS/NZS 4859.1 and be installed so that it—\nforms a continuous barrier with ceilings, walls, bulkheads, floors, slab-edges or the like that inherently contribute to the thermal barrier; and\nis continuous below and around box gutters, parapets and the like; and\nabuts or overlaps adjoining insulation other than at supporting members such as posts, beams, truss chords, rafters, studs, noggings, joists, furring channels, slab edges and the like where the insulation must be against the member; and\ndoes not affect the safe or effective operation of a service or fitting.\n(2) Where required, reflective insulation must be installed with—\nthe necessary airspace to achieve the required R-Value between a reflective side of the reflective insulation and a building lining or cladding; and\nthe reflective insulation closely fitted against any penetration, door or window opening; and\nthe reflective insulation adequately supported by framing members; and\neach adjoining sheet of roll membrane being—\noverlapped not less than 50 mm; or\ntaped together.\n(3) Where required, bulk insulation must be installed so that—\nit maintains its position and thickness, other than where it is compressed between cladding and supporting members, water pipes, electrical cabling or the like; and\nin a ceiling, where there is no bulk insulation or reflective insulation in the wall beneath, it overlaps the wall by not less than 50 mm.\n(4) Roof, ceiling, wall and floor materials, and associated surfaces are deemed to have the thermal properties listed in Specification 36.\n(5) The required Total R-Value and Total System U-Value, including allowance for thermal bridging, must be—\ncalculated in accordance with AS/NZS 4859.2 for a roof or floor; or\ndetermined in accordance with Specification 37 for wall-glazing construction; or\ndetermined in accordance with Specification 39 or Section 3.5 of CIBSE Guide A for soil or sub-floor spaces.","g":"/ncc/j4d3","a19":["J1.2","NSW J(A)1.2"]},{"c":"J4D4","t":"Roof and ceiling construction","p":"Part J4 Building fabric","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j4-building-fabric#J4D4","x":"(1) A roof or ceiling must achieve a Total R-Value greater than or equal to—\nfor a Class 5, 6, 7, 8 or 9b building or a Class 9a building other than a ward area —\nin climate zones 1, 2, 3, 4 and 5 — R3.7 for a downward direction of heat flow; and\nin climate zone 6 — R3.2 for a downward direction of heat flow; and\nin climate zone 7 — R3.7 for an upward direction of heat flow; and\nin climate zone 8 — R4.8 for an upward direction of heat flow.\nfor a Class 3 or 9c building or a Class 9a ward area —\nin climate zones 1, 3, 4 and 6 — R4.8 for a downward direction of heat flow; and\nin climate zone 2 — R4.4 for a downward direction of heat flow; and\nin climate zone 5 — R3.7 for a downward direction of heat flow; and\nin climate zones 7 and 8 — R5.3 in an upward direction of heat flow.\n(2) In climate zones 1, 2, 3, 4, 5, 6 and 7 the upper surface of a roof must have—\na Total Solar Reflectance greater than 0.55 and a thermal emittance greater than 0.85; or\na Solar Reflectance Index greater than 61; or\na solar absorptance of not more than 0.45 and a thermal emittance of greater than 0.85.\n(3) In climate zones 1, 2, 3, 5 and 6 the upper surface of a metal roof, which has outside air intakes, unitary air-conditioning units or air-cooled chillers mounted on it or less than 2 m above it, must have—\na Total Solar Reflectance greater than 0.65 and a thermal emittance greater than 0.85; or\na Solar Reflectance Index greater than 80; or\na solar absorptance of not more than 0.35 and a thermal emittance of greater than 0.85.\n(4) The requirements of (2) and (3) do not apply to the portion of the upper surface of a roof that is beneath a solar photovoltaic panel or a rooftop garden.","g":"/ncc/j4d4","a19":["J1.3"]},{"c":"Table J4D5","t":"Roof lights – Total system SHGC","p":"Part J4 Building fabric","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j4-building-fabric#_62b87d74-280b-4e15-bf14-9a0c9a495ca0","x":"Roof light shaft index Note 1 | Total area of roof lights up to 3.5% of the floor area of the room or space | Total area of roof lights more than 3.5% and up to 5% of the floor area of the room or space\n<1.0 | ≤ 0.45 | ≤ 0.29\n≥ 1.0 to < 2.5 | ≤ 0.51 | ≤ 0.33\n≥ 2.5 | ≤ 0.76 | ≤ 0.49\nTable Notes\nThe roof light shaft index is determined by measuring the distance from the centre of the shaft at the roof to the centre of the shaft at the ceiling level and dividing it by the average internal dimension of the shaft opening at the ceiling level (or the diameter for a circular shaft) in the same units of measurement.\nThe area of a roof light is the area of the roof opening that allows light to enter the building.\nThe total area of roof lights is the combined area for all roof lights serving the room or space.","tb":"J4D5","g":"/ncc/table-j4d5"},{"c":"J4D5","t":"Roof lights","p":"Part J4 Building fabric","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j4-building-fabric#J4D5","x":"Roof lights must have—\na total area of not more than 5% of the floor area of the room or space served; and\ntransparent and translucent elements, including any imperforate ceiling diffuser, with a combined performance of—\nfor Total system SHGC, in accordance with Table J4D5; and\nfor Total system U-Value, not more than U3.9.\nTable J4D5 Roof lights – Total system SHGC\nRoof light shaft index Note 1\nTotal area of roof lights up to 3.5% of the floor area of the room or space\nTotal area of roof lights more than 3.5% and up to 5% of the floor area of the room or space\n<1.0\n≤ 0.45\n≤ 0.29\n≥ 1.0 to < 2.5\n≤ 0.51\n≤ 0.33\n≥ 2.5\n≤ 0.76\n≤ 0.49\nTable Notes\nThe roof light shaft index is determined by measuring the distance from the centre of the shaft at the roof to the centre of the shaft at the ceiling level and dividing it by the average internal dimension of the shaft opening at the ceiling level (or the diameter for a circular shaft) in the same units of measurement.\nThe area of a roof light is the area of the roof opening that allows light to enter the building.\nThe total area of roof lights is the combined area for all roof lights serving the room or space.","g":"/ncc/j4d5","a19":["J1.4"]},{"c":"Table J4D6a","t":"Maximum Total System U-Value of wall-glazing construction","p":"Part J4 Building fabric","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j4-building-fabric#_56983969-94f5-4c13-ac7e-ca01787335d5","x":"Climate zone | Class 5, 6, 7, 8, 9b building or a Class 9a building other than a ward area | Class 3 or 9c building or a Class 9a ward area\n1 | 1.6 | 1.1\n2 | 1.9 | 1.6\n3 | 1.7 | 1.2\n4 | 1.7 | 1.3\n5 | 1.9 | 1.6\n6 | 1.8 | 1.6\n7 | 1.7 | 1.2\n8 | 2.0 | 1.1","tb":"J4D6","g":"/ncc/table-j4d6a"},{"c":"Table J4D6b","t":"Minimum wall Total R-Value - Wall area 80% or more of wall-glazing construction area","p":"Part J4 Building fabric","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j4-building-fabric#_9021ee7a-e789-4295-b134-cfbf812e3cd2","x":"Climate zone | Class 5, 6, 7, 8 or 9b building or a Class 9a building other than a ward area | Class 3 or 9c building or Class 9a ward area\n1 | 3.0 | 4.0\n2 | 1.0 | 1.0\n3 | 2.2 | 2.4\n4 | 2.0 | 1.9\n5 | 1.0 | 1.0\n6 | 1.2 | 1.0\n7 | 2.2 | 2.2\n8 | 3.6 | 3.6","tb":"J4D6","g":"/ncc/table-j4d6b"},{"c":"Table J4D6c","t":"Maximum wall-glazing construction solar admittance - Class 5, 6, 7, 8 or 9b building or Class 9a building other than a ward area","p":"Part J4 Building fabric","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j4-building-fabric#_af513893-4d0e-4865-9482-64d33b185b58","x":"Climate zone | Eastern aspect solar admittance | Northern aspect solar admittance | Southern aspect solar admittance | Western aspect solar admittance\n1 to 7 | 0.10 | 0.09 | 0.11 | 0.09\n8 | 0.10 | 0.10 | 0.20 | 0.10","tb":"J4D6","g":"/ncc/table-j4d6c"},{"c":"Table J4D6d","t":"Maximum wall glazing construction solar admittance - Class 3 or 9c building or Class 9a ward area","p":"Part J4 Building fabric","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j4-building-fabric#_b6ef31b9-5c27-4bb4-9488-77eabc8f692d","x":"Climate zone | Eastern aspect solar admittance | Northern aspect solar admittance | Southern aspect solar admittance | Western aspect solar admittance\nAll | 0.06 | 0.06 | 0.06 | 0.06","tb":"J4D6","g":"/ncc/table-j4d6d"},{"c":"J4D6","t":"Walls and glazing","p":"Part J4 Building fabric","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j4-building-fabric#J4D6","x":"(1) The Total System U-Value of wall-glazing construction, including wall-glazing construction which wholly or partly forms the envelope internally, must not be greater than the values specified in Table J4D6a.\n(2) The Total System U-Value of glazing, including display glazing, must not be greater than U5.8.\n(3) The Total System U-Value of wall-glazing construction must be calculated in accordance with Specification 37.\n(4) Wall components of a wall-glazing construction must achieve a minimum Total R-Value of—\nwhere the wall is less than 80% of the area of the wall-glazing construction, R1.0; or\nwhere the wall is 80% or more of the area of the wall-glazing construction, the value specified in Table J4D6b.\n(5) The solar admittance of externally facing wall-glazing construction, excluding wall-glazing construction which is wholly internal, must not be greater than—\nfor a Class 5, 6, 7, 8 or 9b building or a Class 9a building other than a ward area, the values specified in Table J4D6c; and\nfor a Class 3 or 9c building or a Class 9a ward area, the values specified in Table J4D6d.\n(6) The solar admittance of a wall-glazing construction must be calculated in accordance with Specification 37.\n(7) The Total system SHGC of display glazing must not exceed the lesser of the following:\n0.81 divided by the applicable shading factor specified in S37C7.\n1.\nTable J4D6a Maximum Total System U-Value of wall-glazing construction\nClimate zone\nClass 5, 6, 7, 8, 9b building or a Class 9a building other than a ward area\nClass 3 or 9c building or a Class 9a ward area\n1\n1.6\n1.1\n2\n1.9\n1.6\n3\n1.7\n1.2\n4\n1.7\n1.3\n5\n1.9\n1.6\n6\n1.8\n1.6\n7\n1.7\n1.2\n8\n2.0\n1.1\nTable J4D6b Minimum wall Total R-Value - Wall area 80% or more of wall-glazing construction area\nClimate zone\nClass 5, 6, 7, 8 or 9b building or a Class 9a building other than a ward area\nClass 3 or 9c building or Class 9a ward area\n1\n3.0\n4.0\n2\n1.0\n1.0\n3\n2.2\n2.4\n4\n2.0\n1.9\n5\n1.0\n1.0\n6\n1.2\n1.0\n7\n2.2\n2.2\n8\n3.6\n3.6\nTable J4D6c Maximum wall-glazing construction solar admittance - Class 5, 6, 7, 8 or 9b building or Class 9a building other than a ward area\nClimate zone\nEastern aspect solar admittance\nNorthern aspect solar admittance\nSouthern aspect solar admittance\nWestern aspect solar admittance\n1 to 7\n0.10\n0.09\n0.11\n0.09\n8\n0.10\n0.10\n0.20\n0.10\nTable J4D6d Maximum wall glazing construction solar admittance - Class 3 or 9c building or Class 9a ward area\nClimate zone\nEastern aspect solar admittance\nNorthern aspect solar admittance\nSouthern aspect solar admittance\nWestern aspect solar admittance\nAll\n0.06\n0.06\n0.06\n0.06","g":"/ncc/j4d6","a19":["J1.5"]},{"c":"Table J4D7","t":"Floors – Minimum Total R-Value","p":"Part J4 Building fabric","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j4-building-fabric#_00af1266-4ce2-442b-a67f-025fd62f0e5b","x":"Location | Climate zone 1— upwards heat flow | Climate zones 2 and 3 — upwards and downwards heat flow | Climate zones 4, 5, 6 and 7 — downwards heat flow | Climate zone 8 — downwards heat flow\nA floor without an in-slab heating or cooling system | 2.0 | 2.0 | 2.0 | 3.5\nA floor with an in-slab heating or cooling system | 3.25 | 3.25 | 3.25 | 4.75\nTable Notes\nFor the purpose of calculating the Total R-Value of a floor, the sub-floor and soil R-Value must be calculated in accordance with Specification 39 or Section 3.5 of CIBSE Guide A.","tb":"J4D7","g":"/ncc/table-j4d7"},{"c":"J4D7","t":"Floors","p":"Part J4 Building fabric","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j4-building-fabric#J4D7","x":"(1) A floor must achieve the Total R-Value specified in Table J4D7.\n(2) For the purposes of (1), a slab-on-ground that does not have an in-slab heating or cooling system is considered to achieve a Total R-Value of R2.0, except—\nin climate zone 8; or\na Class 3, Class 9a ward area or Class 9c building in climate zone 7 that has a floor area to floor perimeter ratio of less than or equal to 2.\n(3) A floor must be insulated around the vertical edge of its perimeter with insulation having an R-Value greater than or equal to 1.0 when the floor—\nis a concrete slab-on-ground in climate zone 8; or\nhas an in-slab or in-screed heating or cooling system, except where used solely in a bathroom, amenity area or the like.\n(4) Insulation required by (3) for a concrete slab-on-ground must—\nbe water resistant; and\nbe continuous from the adjacent finished ground level—\nto a depth not less than 300 mm; or\nfor the full depth of the vertical edge of the concrete slab-on-ground.\nTable J4D7 Floors – Minimum Total R-Value\nLocation\nClimate zone 1— upwards heat flow\nClimate zones 2 and 3 — upwards and downwards heat flow\nClimate zones 4, 5, 6 and 7 — downwards heat flow\nClimate zone 8 — downwards heat flow\nA floor without an in-slab heating or cooling system\n2.0\n2.0\n2.0\n3.5\nA floor with an in-slab heating or cooling system\n3.25\n3.25\n3.25\n4.75\nTable Notes\nFor the purpose of calculating the Total R-Value of a floor, the sub-floor and soil R-Value must be calculated in accordance with Specification 39 or Section 3.5 of CIBSE Guide A.","g":"/ncc/j4d7","a19":["J1.6"]},{"c":"J5D1","t":"Deemed-to-Satisfy Provisions","p":"Part J5 Building sealing","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j5-building-sealing#J5D1","x":"(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements J1P1 to J1P4 are satisfied by complying with—\nJ2D2; and\nJ3D2 to J3D15; and\nJ4D2 to J4D7; and\nJ5D2 to J5D8; and\nJ6D2 to J6D13; and\nJ7D2 to J7D9; and\nJ8D2 to J8D5; and\nJ9D2 to J9D5.\n(2) Where a Performance Solution is proposed, the relevant Performance Requirements must be determined in accordance with A2G2(3) and A2G4(3) as applicable.","g":"/ncc/j5d1","a19":["J3.0"]},{"c":"J5D2","t":"Application of Part","p":"Part J5 Building sealing","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j5-building-sealing#J5D2","x":"(1) The Deemed-to-Satisfy Provisions of this Part apply to—\nelements forming the envelope of a Class 3, 5, 6, 7, 8 or 9 building; and\nthe external building fabric of a Class 4 part of a building.\n(2) Notwithstanding (1), the Deemed-to-Satisfy Provisions of this Part do not apply to—\na building in climate zones 1, 2, 3 or 5 where the only means of air-conditioning is by using an evaporative cooler; or\na permanent building opening, in a space where a gas appliance is located, that is necessary for the safe operation of a gas appliance; or\na building or space where the mechanical ventilation required by Part F6 provides sufficient pressurisation to prevent infiltration.","g":"/ncc/j5d2","a19":["J3.1","NSW J(A)2.1"]},{"c":"J5D3","t":"Chimneys and flues","p":"Part J5 Building sealing","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j5-building-sealing#J5D3","x":"The chimney or flue of an open solid-fuel burning appliance must be provided with a damper or flap that can be closed to seal the chimney or flue.","g":"/ncc/j5d3","a19":["J3.2"]},{"c":"J5D4","t":"Roof lights","p":"Part J5 Building sealing","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j5-building-sealing#J5D4","x":"A roof light must be sealed, or capable of being sealed, with—\nan imperforate ceiling diffuser or the like installed at the ceiling or internal lining level; or\na weatherproof seal; or\na shutter system readily operated either manually, mechanically or electronically by the occupant.","g":"/ncc/j5d4","a19":["J3.3"]},{"c":"J5D5","t":"Windows and doors","p":"Part J5 Building sealing","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j5-building-sealing#J5D5","x":"(1) A door, openable window or the like must be sealed.\n(2) The requirements of (1) do not apply to—\na window complying with AS 2047; or\na fire door or smoke door; or\na roller shutter door, roller shutter grille or other security door or device installed only for out-of-hours security.\n(3) A seal to restrict air infiltration—\nfor the bottom edge of a door, must be a draft protection device; and\nfor the other edges of a door or the edges of an openable window or other such opening, may be a foam or rubber compression strip, fibrous seal or the like.\n(4) An entrance to a building, must have an airlock, self-closing door, rapid roller door, revolving door or the like, other than—\nwhere the room containing the entrance has a floor area of not more than 50 m2; or\nwhere a café, restaurant, open front shop or the like has—\nan un-conditioned zone at least 3 m deep between the main entrance, including an open front, and a conditioned space; and\nat all other entrances to the café, restaurant, open front shop or the like, self-closing doors; or\nwhere the entrance is a moveable external wall with the capability to open for the purpose of creating a temporary unconditioned space; or\nwhere, for the safety of the building occupants or for the intended use of the facility, it is required to be left open to a temporary unconditioned space at an early childhood centre, preschool, school, or the like; or\nwhere the entrance serves a Class 3 sole-occupancy unit or a Class 4 part of a building.\n(5) A loading dock entrance, if leading to a conditioned space, must be fitted with a rapid roller door or the like.","g":"/ncc/j5d5","a19":["J3.4"]},{"c":"J5D6","t":"Exhaust fans","p":"Part J5 Building sealing","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j5-building-sealing#J5D6","x":"An exhaust fan must be fitted with a sealing device such as a self-closing damper or the like unless it is necessary for the fan to operate continuously.","g":"/ncc/j5d6","a19":["J3.5"]},{"c":"J5D7","t":"Construction of roofs, ceilings, walls and floors","p":"Part J5 Building sealing","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j5-building-sealing#J5D7","x":"(1) Ceilings, walls, floors and any opening such as a window frame, door frame, roof light frame, ventilation opening frame or the like must be constructed to minimise air leakage.\n(2) Construction required by (1) must be—\nenclosed by internal lining systems that are close fitting at ceiling, wall and floor junctions; or\nsealed at junctions and penetrations with—\nclose fitting architrave, skirting or cornice; or\nexpanding foam, rubber compressible strip, caulking or the like.\n(3) The requirements of (1) do not apply to openings, grilles, louvres or the like required for smoke hazard management.","g":"/ncc/j5d7","a19":["J3.6"]},{"c":"J5D8","t":"Evaporative coolers","p":"Part J5 Building sealing","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j5-building-sealing#J5D8","x":"An evaporative cooler must be fitted with a self-closing damper or the like in climate zones 4, 5, 6, 7 and 8.","g":"/ncc/j5d8","a19":["J3.7"]},{"c":"J6D1","t":"Deemed-to-Satisfy Provisions","p":"Part J6 Air-conditioning and ventilation","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j6-air-conditioning-and-ventilation#J6D1","x":"(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements J1P1 to J1P4 are satisfied by complying with—\nJ2D2; and\nJ3D2 to J3D15; and\nJ4D2 to J4D7; and\nJ5D2 to J5D8; and\nJ6D2 to J6D13; and\nJ7D2 to J7D9; and\nJ8D2 to J8D5; and\nJ9D2 to J9D5.\n(2) Where a Performance Solution is proposed, the relevant Performance Requirements must be determined in accordance with A2G2(3) and A2G4(3) as applicable.","g":"/ncc/j6d1","a19":["J5.0"]},{"c":"J6D2","t":"Application of Part","p":"Part J6 Air-conditioning and ventilation","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j6-air-conditioning-and-ventilation#J6D2","x":"The Deemed-to-Satisfy Provisions of this Part do not apply to a Class 8 electricity network substation.","g":"/ncc/j6d2","a19":["J5.1","NSW J(A)3.1"]},{"c":"Table J6D3","t":"Requirement for an outdoor air economy cycle","p":"Part J6 Air-conditioning and ventilation","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j6-air-conditioning-and-ventilation#_65d17f0e-6675-4efe-916c-9afa93003eb2","x":"Climate zone | Total air flow rate requiring an economy cycle (L/s)\n2 | 9000\n3 | 7500\n4 | 3500\n5 | 3000\n6 | 1200\n7 | 2500\n8 | 2000","tb":"J6D3","g":"/ncc/table-j6d3"},{"c":"J6D3","t":"Air-conditioning system control","p":"Part J6 Air-conditioning and ventilation","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j6-air-conditioning-and-ventilation#J6D3","x":"(1) An air-conditioning system—\nmust be capable of being deactivated when the building or part of a building served by that system is not occupied; and\nmust not use a single heating coil or a single cooling coil in an air-handling unit to serve more than one air-conditioning zone where one zone will require heating at the same time another requires cooling; and\nwhen serving more than one air-conditioning zone or area with different heating or cooling needs, must—\nthermostatically control the temperature of each zone or area; and\nnot control the temperature by mixing actively heated air and actively cooled air; and\nserve diverse loads through modulating airflow to the maximum extent practicable; and\nlimit zone-level reheating of air cooled by equipment upstream of the zone to not more than 7.5°C at any intended airflow rate; and\nlimit zone-level re-cooling of air heated by equipment upstream of the zone to not more than 7.5°C at any intended airflow rate; and\nwhich provides the required mechanical ventilation, other than in climate zone 1 or where dehumidification control is needed, must have an outdoor air economy cycle if the total air flow rate of any airside component of an air-conditioning system is greater than or equal to the flow rates in Table J6D3; and\nwhich contains more than one water heater, chiller or coil, must be capable of stopping the flow of water to those not operating; and\nwhen serving a sole-occupancy unit in a Class 3 building, must not operate when any external door of the sole-occupancy unit is open for more than one minute; and\nmust have the ability to use direct signals from the control components responsible for the delivery of comfort conditions in the building to regulate the operation of central plant; and\nmust have a control dead band of not less than 2°C, except where a smaller range is required for specialised applications; and\nmust be provided with balancing dampers and balancing valves, as required to meet the needs of the system at its maximum operating condition, that ensure the maximum design air or fluid flow is achieved but not exceeded by more than 15% above design at each—\ncomponent; or\ngroup of components operating under a common control in a system containing multiple components; and\nmust ensure that each independently operating space of more than 1000 m2 and every separate floor of the building has provision to terminate airflow independently of the remainder of the system sufficient to allow for different operating times; and\nwhere the design maximum heated water temperature is greater than 45°C, must be capable of automatic variable temperature operation of heated water circuits; and\nwhen deactivated, must close any motorised outdoor air or return air damper that is not otherwise being actively controlled; and\nmust be capable of automatic variable temperature operation of chilled water circuits; and\nwhere fitted with a cooling tower, must automatically vary the condenser water set point temperature across the full range of condenser water inlet temperatures permitted by the equipment being served.\n(2) When two or more air-conditioning systems serve the same space they must use control sequences that prevent the systems from operating in opposing heating and cooling modes.\n(3) A time switch must be provided to control—\nan air-conditioning system of more than 2 kWr; and\na heater of more than 1 kWheating used for air-conditioning.\n(4) A time switch under (3) must—\nbe capable of switching electric power on and off at variable pre-programmed times and on variable pre-programmed days; and\nhave the ability to program public holidays at least 1 year ahead; and\nbe capable of being overridden by—\na demand-operated control; or\na manual switch; and\nallow the resumption of normal operation no longer than 2 hours after any override is activated.\n(5) The requirements of (3) and (4) do not apply to—\nan air-conditioning system that serves—\nonly one sole-occupancy unit in a Class 3 or 9c building; or\nonly a Class 4 part of a building; or\na conditioned space where air-conditioning is needed for 24 hour continuous use.\nTable J6D3 Requirement for an outdoor air economy cycle\nClimate zone\nTotal air flow rate requiring an economy cycle (L/s)\n2\n9000\n3\n7500\n4\n3500\n5\n3000\n6\n1200\n7\n2500\n8\n2000","g":"/ncc/j6d3","a19":["J5.2"]},{"c":"Table J6D4","t":"Required outdoor air treatment","p":"Part J6 Air-conditioning and ventilation","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j6-air-conditioning-and-ventilation#_dd383d02-54a7-4f5a-a8a5-df634c90f309","x":"Climate zone | Outdoor air flow (L/s) | Required measure - where demand control ventilation is appropriate | Required measure - where demand control ventilation is not appropriate\n1 | ≤120 | No required measure | No required measure\n1 | >120 to ≤2000 | Modulating control | No required measure\n1 | >2000 | Modulating control | Indirect evaporative cooling system\n2 | ≤400 | No required measure | No required measure\n2 | >400 | Modulating control | No required measure\n3 | ≤400 | No required measure | No required measure\n3 | >400 to ≤2000 | Modulating control | No required measure\n3 | >2000 | Modulating control | Indirect evaporative cooling system\n4 | ≤400 | No required measure | No required measure\n4 | >400 to ≤500 | Modulating control | No required measure\n4 | >500 | Modulating control | Energy reclaiming system\n5 | ≤400 | No required measure | No required measure\n5 | >400 to ≤1000 | Modulating control | No required measure\n5 | >1000 | Modulating control | Energy reclaiming system\n6 | ≤500 | No required measure | No required measure\n6 | >500 | Modulating control | Energy reclaiming system\n7 | ≤250 | No required measure | No required measure\n7 | >250 | Modulating control | Energy reclaiming system\n8 | ≤100 | No required measure | No required measure\n8 | >100 to ≤250 | Modulating control | No required measure\n8 | >250 | Modulating control | Energy reclaiming system","tb":"J6D4","g":"/ncc/table-j6d4"},{"c":"J6D4","t":"Mechanical ventilation system control","p":"Part J6 Air-conditioning and ventilation","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j6-air-conditioning-and-ventilation#J6D4","x":"(1) A mechanical ventilation system, including one that is part of an air-conditioning system, except where the mechanical system serves only a Class 4 part of a building, must be capable of being deactivated when the building or part of the building served by that system is not occupied.\n(2) When serving a conditioned space, except in periods when evaporative cooling is being used, a mechanical ventilation system must—\nwhere specified in Table J6D4, have—\nan energy reclaiming system that—\npreconditions outdoor air at a minimum sensible heat transfer effectiveness of 60%; and\nis capable of allowing outdoor air to bypass the heat reclaiming system when the conditions do not provide a heat reclaim benefit; or\nindirect evaporative cooling that—\nincorporates an energy reclaiming system meeting the requirements of (i); and\nhas a minimum humidification efficiency of 85%; or\ndemand control ventilation in accordance with AS 1668.2 if appropriate to the application; and\nnot exceed the minimum outdoor air quantity required by Part F6 by more than 20%, except—\nwhen additional unconditioned outdoor air is supplied for free cooling; or\nwhere additional mechanical ventilation is needed to balance the required exhaust or process exhaust; or\nwhere an energy reclaiming system meeting the requirements of (2)(a)(i) preconditions all the outdoor air.\n(3) An exhaust system with an air flow rate of more than 1000 L/s must be capable of stopping the motor when the system is not needed, except for an exhaust system in a sole-occupancy unit in a Class 3 or 9c building.\n(4) A time switch must be provided to a mechanical ventilation system with an air flow rate of more than 1000 L/s.\n(5) The time switch provided under (4) must—\nbe capable of switching electric power on and off at variable pre-programmed times and on variable pre-programmed days; and\nhave the ability to program public holidays at least 1 year ahead; and\nbe capable of being overridden by—\na demand-operated control; or\na manual switch; and\nallow the resumption of normal operation no longer than 2 hours after any override is activated.\n(6) The requirements of (2), (4) and (5) do not apply to a mechanical ventilation system that serves—\nonly one sole-occupancy unit in a Class 3 or 9c building; or\nonly a Class 4 part of a building.\n(7) The requirements of (4) and (5) do not apply to—\na building where mechanical ventilation is needed for 24 hour occupancy; or\na carpark exhaust system; or\na mechanical ventilation system that is required to operate 24/7 to manage air contaminants, maintain pressurisation or the like.\nTable J6D4 Required outdoor air treatment\nClimate zone\nOutdoor air flow (L/s)\nRequired measure - where demand control ventilation is appropriate\nRequired measure - where demand control ventilation is not appropriate\n1\n≤120\nNo required measure\nNo required measure\n1\n>120 to ≤2000\nModulating control\nNo required measure\n1\n>2000\nModulating control\nIndirect evaporative cooling system\n2\n≤400\nNo required measure\nNo required measure\n2\n>400\nModulating control\nNo required measure\n3\n≤400\nNo required measure\nNo required measure\n3\n>400 to ≤2000\nModulating control\nNo required measure\n3\n>2000\nModulating control\nIndirect evaporative cooling system\n4\n≤400\nNo required measure\nNo required measure\n4\n>400 to ≤500\nModulating control\nNo required measure\n4\n>500\nModulating control\nEnergy reclaiming system\n5\n≤400\nNo required measure\nNo required measure\n5\n>400 to ≤1000\nModulating control\nNo required measure\n5\n>1000\nModulating control\nEnergy reclaiming system\n6\n≤500\nNo required measure\nNo required measure\n6\n>500\nModulating control\nEnergy reclaiming system\n7\n≤250\nNo required measure\nNo required measure\n7\n>250\nModulating control\nEnergy reclaiming system\n8\n≤100\nNo required measure\nNo required measure\n8\n>100 to ≤250\nModulating control\nNo required measure\n8\n>250\nModulating control\nEnergy reclaiming system","g":"/ncc/j6d4","a19":["J5.3"]},{"c":"Table J6D5a","t":"Minimum fan performance grade","p":"Part J6 Air-conditioning and ventilation","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j6-air-conditioning-and-ventilation#_d3173441-5bfb-467d-8b0f-a0ac83a99f13","x":"Fan type | Installation type A or C | Installation type B or D\nAll fans as a component of an air-handling unit or fan coil unit | 61 | 64\nAxial | 40 | 58\nMixed flow | 50 | 62\nCentrifugal forward-curved | 44 | 49\nCentrifugal radial bladed | 44 | 49\nCentrifugal backward-curved | 61 | 64\nTable Notes\nInstallation type A means an arrangement where the fan is installed with free inlet and outlet conditions.\nInstallation type B means an arrangement where the fan is installed with a free inlet and a duct at its outlet.\nInstallation type C means an arrangement where the fan is installed with a duct fitted to its inlet and with free outlet conditions.\nInstallation type D means an arrangement where the fan is installed with a duct fitted to its inlet and outlet.","tb":"J6D5","g":"/ncc/table-j6d5a"},{"c":"Table J6D5b","t":"Fan regression coefficient a","p":"Part J6 Air-conditioning and ventilation","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j6-air-conditioning-and-ventilation#_c46b9d61-2d9b-4f1c-a2ab-f5cbd9a674c4","x":"Fan type | Fan motor input power < 10 kW | Fan motor input power ≥ 10 kW\nAxial | 2.74 | 0.78\nMixed flow | 4.56 | 1.1\nCentrifugal forward-curved | 2.74 | 0.78\nCentrifugal radial bladed | 2.74 | 0.78\nCentrifugal backward-curved | 4.56 | 1.1","tb":"J6D5","g":"/ncc/table-j6d5b"},{"c":"Table J6D5c","t":"Fan regression coefficient b","p":"Part J6 Air-conditioning and ventilation","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j6-air-conditioning-and-ventilation#_c1caa03f-4f3d-4d4b-918a-4c51ee9ba4c7","x":"Fan type | Fan motor input power < 10 kW | Fan motor input power ≥ 10 kW\nAxial | 6.33 | 1.88\nMixed flow | 10.5 | 2.6\nCentrifugal forward-curved | 6.33 | 1.88\nCentrifugal radial bladed | 6.33 | 1.88\nCentrifugal backward-curved | 10.5 | 2.6","tb":"J6D5","g":"/ncc/table-j6d5c"},{"c":"Table J6D5d","t":"Maximum coil pressure drop","p":"Part J6 Air-conditioning and ventilation","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j6-air-conditioning-and-ventilation#_cfbcf5eb-ee4f-4bc6-8754-84a0b71943c4","x":"Number of rows | Maximum pressure drop (Pa)\n1 | 30\n2 | 50\n4 | 90\n6 | 130\n8 | 175\n10 | 220","tb":"J6D5","g":"/ncc/table-j6d5d"},{"c":"Table J6D5e","t":"Maximum clean filter pressure drop","p":"Part J6 Air-conditioning and ventilation","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j6-air-conditioning-and-ventilation#_45355acf-61b9-4c50-9188-88fa93392a3e","x":"Filter minimum efficiency reporting value | Maximum pressure drop (Pa)\n9 | 55\n11 | 65\n13 | 95\n14 | 110","tb":"J6D5","g":"/ncc/table-j6d5e"},{"c":"J6D5","t":"Fans and duct systems","p":"Part J6 Air-conditioning and ventilation","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j6-air-conditioning-and-ventilation#J6D5","x":"(1) Fans, ductwork and duct components that form part of an air-conditioning system or mechanical ventilation system must—\nseparately comply with (2) to (12); or\nachieve a fan motor input power per unit of flowrate lower than the fan motor input power per unit of flowrate achieved when applying (2) to (12) together.\n(2)\nSubject to (6), fans, other than roof mounted ventilation fans with cowlings, must have a peak efficiency, determined in accordance with Specification 46, of not less than, [formula] where——\n[formula] = the minimum required peak system static efficiency for installation type A or C or the minimum peak system total efficiency for installation type B or D; and\n[formula] = the electrical input power of the fan (kW) at peak efficiency point, including any integrated motor control equipment; and\n[formula] = the minimum performance grade obtained from Table J6D5a; and\n[formula] = regression coefficient a, obtained from Table J6D5b; and\n[formula] = regression coefficient b, obtained from Table J6D5c; and\n[formula] = natural logarithm.\n(3) Subject to (6), roof mounted ventilation fans with cowlings must—\nwhere the electrical input power of the fan at peak efficiency point, including any integrated motor control equipment, is less than or equal to 30 kW, have peak efficiency, determined in accordance withSpecification 46, of not less than, [formula] where—\n[formula] = the minimumrequiredsystem static efficiency for installation type A or C or the minimumrequiredsystem total efficiency for installation type B or D; and\n[formula] = the electrical input power of the fan (kW) at peak efficiency point, including any integrated motor control equipment; and\n[formula] = natural logarithm; and\nwhere the electrical input power of the fan at peak efficiency point, including any integrated motor control equipment, is greater than 30 kW—\nhave a peak system static efficiency of not less than 56% for installation type A or C; or\na peak system total efficiency of not less than 56% for installation type B or D.\n(4) Subject to (6), fans must either—\nindividually, have a fan power ratio, determined in accordance with Specification 46, of less than 0.96; or\ncollectively, have an average fan power ratio, determined in accordance with Specification 46, of less than 0.96.\n(5) Where a fan’s electrical power input, including any integrated motor control equipment, at the peak efficiency point and full speed, is greater than 750 W—\nthe fan must be capable of variable speed operation; and\nwhere serving a single room or space, the fan must be capable of operating at reduced flow when conditions in the room or space served are within the temperature control deadband if applicable; and\nwhere serving more than one room or space, the fan and the system it serves must—\nbe capable of variable volume operation; and\noperate to a variable pressure to the extent practicable.\n(6) The requirements of (2) to (5) do not apply to fans—\nwith electrical input power less than or equal to 125 W; or\nthat need to explosion proof; or\nthat are supply fans inside unitary air-conditioning equipment.\n(7) The pressure drop in the index run across all straight sections of rigid ductwork and all sections of flexible ductwork must not exceed 1 Pa/m when averaged over the entire length of straight rigid duct and flexible duct. The pressure drop of flexible ductwork sections may be calculated as if the flexible ductwork is laid straight.\n(8) Flexible ductwork must not account for more than 6 m total length in any duct run.\n(9) The upstream connection to ductwork fittings in the index run must have an equivalent diameter to the connected duct.\n(10) Turning vanes must be included in all rigid ductwork elbows with an angle of 90°, or more acute than 90°, in the index run except where—\nthe inclusion of turning vanes presents a fouling risk; or\na long radius bend in accordance with AS 4254.2 is used.\n(11) For ductwork components in the index run—\nthe pressure drop across a coil must not exceed the value specified in Table J6D5d; and\na high efficiency particulate arrestance (HEPA) air filter must not exceed the higher of—\na pressure drop of 200 Pa when clean; or\nthe filter design pressure drop when clean at an air velocity of 1.5 m/s; and\nany other air filter must not exceed—\nthe pressure drop specified in Table J6D5e when clean; or\nthe filter design pressure drop when clean at an air velocity of 2.5 m/s; and\nthe pressure drop across intake louvres, relief louvres and exhaust louvres must not exceed—\nfor single stage louvres, 30 Pa; and\nfor two stage louvres, 60 Pa; and\nfor acoustic louvres, 50 Pa; and\nfor other non-weatherproof louvres, 30 Pa; and\nthe pressure drop across a variable air volume box, with the damper in the fully open position, must not exceed—\nfor units with electric reheat, 100 Pa; and\nfor other units, 25 Pa not including coil pressure losses; and\nrooftop cowls must not exceed a pressure drop of 30 Pa; and\nattenuators must not exceed a pressure drop of 40 Pa; and\nfire dampers must not exceed a pressure drop of 15 Pa when open; and\nbalancing and control dampers in the index run must not exceed a pressure drop of 25 Pa when in the fully open position; and\nsupply air diffusers and grilles must not exceed a pressure drop of 40 Pa; and\nexhaust grilles must not exceed a pressure drop of 30 Pa; and\ntransfer ducts must not exceed a pressure drop of 12 Pa; and\ndoor grilles and door undercuts must not exceed a pressure drop of 12 Pa; and\nactive chilled beams must not exceed a pressure drop of 150 Pa.\n(12) The requirements of (1) to (11) do not apply to—\nfans in unducted air-conditioning systems with a supply air capacity of less than 1000 L/s; and\nfans which are dedicated solely to fire and smoke control; and\nthe power for process-related components; and\nkitchen exhaust systems.\nTable J6D5a Minimum fan performance grade\nFan type\nInstallation type A or C\nInstallation type B or D\nAll fans as a component of an air-handling unit or fan coil unit\n61\n64\nAxial\n40\n58\nMixed flow\n50\n62\nCentrifugal forward-curved\n44\n49\nCentrifugal radial bladed\n44\n49\nCentrifugal backward-curved\n61\n64\nTable Notes\nInstallation type A means an arrangement where the fan is installed with free inlet and outlet conditions.\nInstallation type B means an arrangement where the fan is installed with a free inlet and a duct at its outlet.\nInstallation type C means an arrangement where the fan is installed with a duct fitted to its inlet and with free outlet conditions.\nInstallation type D means an arrangement where the fan is installed with a duct fitted to its inlet and outlet.\nTable J6D5b Fan regression coefficient a\nFan type\nFan motor input power < 10 kW\nFan motor input power ≥ 10 kW\nAxial\n2.74\n0.78\nMixed flow\n4.56\n1.1\nCentrifugal forward-curved\n2.74\n0.78\nCentrifugal radial bladed\n2.74\n0.78\nCentrifugal backward-curved\n4.56\n1.1\nTable J6D5c Fan regression coefficient b\nFan type\nFan motor input power < 10 kW\nFan motor input power ≥ 10 kW\nAxial\n6.33\n1.88\nMixed flow\n10.5\n2.6\nCentrifugal forward-curved\n6.33\n1.88\nCentrifugal radial bladed\n6.33\n1.88\nCentrifugal backward-curved\n10.5\n2.6\nTable J6D5d Maximum coil pressure drop\nNumber of rows\nMaximum pressure drop (Pa)\n1\n30\n2\n50\n4\n90\n6\n130\n8\n175\n10\n220\nTable J6D5e Maximum clean filter pressure drop\nFilter minimum efficiency reporting value\nMaximum pressure drop (Pa)\n9\n55\n11\n65\n13\n95\n14\n110","g":"/ncc/j6d5","a19":["J5.4"]},{"c":"Table J6D6","t":"Ductwork and fittings – Minimum insulation R-Value","p":"Part J6 Air-conditioning and ventilation","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j6-air-conditioning-and-ventilation#_31573c27-78e8-4d2f-b330-b0c288e88233","x":"Location of ductwork and fittings | Climate zone 1, 2, 3, 4, 5, 6 or 7 | Climate zone 8\nWithin a conditioned space | 1.2 | 2.0\nWhere exposed to direct sunlight | 3.0 | 3.0\nAll other locations | 2.0 | 3.0","tb":"J6D6","g":"/ncc/table-j6d6"},{"c":"J6D6","t":"Ductwork insulation","p":"Part J6 Air-conditioning and ventilation","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j6-air-conditioning-and-ventilation#J6D6","x":"(1) Ductwork and fittings in an air-conditioning system must be provided with insulation—\ncomplying with AS/NZS 4859.1; and\nhaving an insulation R-Value greater than or equal to—\nfor flexible ductwork, 1.0; or\nfor cushion boxes, that of the connecting ductwork; or\nthat specified in Table J6D6.\n(2) Insulation must—\nbe protected against the effects of weather and sunlight; and\nbe installed so that it—\nabuts adjoining insulation to form a continuous barrier; and\nmaintains its position and thickness, other than at flanges and supports; and\nwhen conveying cooled air—\nbe protected by a vapour barrier on the outside of the insulation; and\nwhere the vapour barrier is a membrane, be installed so that adjoining sheets of the membrane—\noverlap by at least 50 mm; and\nare bonded or taped together.\n(3) The requirements of (1) do not apply to—\nductwork and fittings located within the only or last room served by the system; or\nfittings that form part of the interface with the conditioned space; or\nreturn air ductwork in, or passing through, a conditioned space; or\nductwork for outdoor air and exhaust air associated with an air-conditioning system; or\nthe floor of an in-situ air-handling unit; or\nflexible fan connections.\n(4) For the purposes of (1), (2) and (3), ductwork and fittings—\ninclude non-active components of a ductwork system such as cushion boxes; and\nexclude active components such as air-handling unit components, fan coil units of air-conditioning or the like.\nTable J6D6 Ductwork and fittings – Minimum insulation R-Value\nLocation of ductwork and fittings\nClimate zone 1, 2, 3, 4, 5, 6 or 7\nClimate zone 8\nWithin a conditioned space\n1.2\n2.0\nWhere exposed to direct sunlight\n3.0\n3.0\nAll other locations\n2.0\n3.0","g":"/ncc/j6d6","a19":["J5.5"]},{"c":"J6D7","t":"Ductwork sealing","p":"Part J6 Air-conditioning and ventilation","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j6-air-conditioning-and-ventilation#J6D7","x":"Ductwork in an air-conditioning system with a capacity of 3000 L/s or greater, not located within the only or last room served by the system, must be sealed against air loss in accordance with the duct sealing requirements of AS 4254.1 and AS 4254.2 for the static pressure in the system.","g":"/ncc/j6d7","a19":["J5.6"]},{"c":"Table J6D8a","t":"Maximum pipework pressure drop – Non-distributive constant flow systems","p":"Part J6 Air-conditioning and ventilation","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j6-air-conditioning-and-ventilation#_8241d16c-0d82-4c48-8617-e548eb0ba1bf","x":"Nominal pipe diameter (mm) | Maximum pressure drop in systems operating 5000 hours/annum or less (Pa/m) | Maximum pressure drop in systems operating more than 5000 hours/annum (Pa/m)\nNot more than 20 | 400 | 400\n25 | 400 | 400\n32 | 400 | 400\n40 | 400 | 400\n50 | 400 | 350\n65 | 400 | 350\n80 | 400 | 350\n100 | 400 | 200\n125 | 400 | 200\n150 or more | 400 | 200","tb":"J6D8","g":"/ncc/table-j6d8a"},{"c":"Table J6D8b","t":"Maximum pipework pressure drop – Non-distributive variable flow systems","p":"Part J6 Air-conditioning and ventilation","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j6-air-conditioning-and-ventilation#_f39ae716-447b-4a68-a0bc-6542c90d690f","x":"Nominal pipe diameter (mm) | Maximum pressure drop in systems operating 5000 hours/annum or less (Pa/m) | Maximum pressure drop in systems operating more than 5000 hours/annum (Pa/m)\nNot more than 20 | 400 | 400\n25 | 400 | 400\n32 | 400 | 400\n40 | 400 | 400\n50 | 400 | 400\n65 | 400 | 400\n80 | 400 | 400\n100 | 400 | 300\n125 | 400 | 300\n150 or more | 400 | 300","tb":"J6D8","g":"/ncc/table-j6d8b"},{"c":"Table J6D8c","t":"Maximum pipework pressure drop – Distributive constant flow systems","p":"Part J6 Air-conditioning and ventilation","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j6-air-conditioning-and-ventilation#_ee04a28d-20d7-4be2-b536-76bc32333402","x":"Nominal pipe diameter (mm) | Maximum pressure drop in systems operating 2000 hours/annum or less (Pa/m) | Maximum pressure drop in systems operating between 2000 hours/annum and 5000 hrs/yr (Pa/m) | Maximum pressure drop in systems operating more than 5000 hours/annum (Pa/m)\nNot more than 20 | 400 | 300 | 150\n25 | 400 | 220 | 100\n32 | 400 | 220 | 100\n40 | 400 | 220 | 100\n50 | 400 | 220 | 100\n65 | 400 | 400 | 170\n80 | 400 | 400 | 170\n100 | 400 | 400 | 170\n125 | 400 | 400 | 170\n150 or more | 400 | 400 | 170","tb":"J6D8","g":"/ncc/table-j6d8c"},{"c":"Table J6D8d","t":"Maximum pipework pressure drop – Distributive variable flow systems","p":"Part J6 Air-conditioning and ventilation","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j6-air-conditioning-and-ventilation#_35d589fa-01f1-44a1-8b6c-aeb65ac9181d","x":"Nominal pipe diameter (mm) | Maximum pressure drop in systems operating 5000 hours/annum or less (Pa/m) | Maximum pressure drop in systems operating more than 5000 hours/annum (Pa/m)\nNot more than 20 | 400 | 250\n25 | 400 | 180\n32 | 400 | 180\n40 | 400 | 180\n50 | 400 | 180\n65 | 400 | 300\n80 | 400 | 300\n100 | 400 | 300\n125 | 400 | 300\n150 or more | 400 | 300","tb":"J6D8","g":"/ncc/table-j6d8d"},{"c":"J6D8","t":"Pump systems","p":"Part J6 Air-conditioning and ventilation","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j6-air-conditioning-and-ventilation#J6D8","x":"(1) General — Pumps and pipework that form part of an air-conditioning system must either—\nseparately comply with (2), (3), (4), (5), (6) and (7); or\nachieve a pump motor power per unit of flowrate lower than the pump motor power per unit of flowrate achieved when applying (2), (3), (4), (5), (6) and (7) together.\n(2) Where the pump motor power input at the duty point is greater than 750 W, a pump must be capable of—\nvariable speed operation; and\nwhere serving a distributive system—\nvariable volume operation; and\nvariable pressure operation to the extent permitted by—\nstatic head requirements; and\nthe requirements of downstream equipment.\n(3) A distributive system must not have—\nuncontrolled bypasses; or\nthree port valves.\n(4) The requirements of (3)(b) do not apply to a distributive system with a single chiller, including a chiller used for space heating, that serves—\nair-conditioning systems with a total co-incident design load of less than 200 kW; or\nonly one heating coil or one cooling coil.\n(5) Circulator pumps — A glandless impeller pump, with a rated hydraulic power output of less than 2.5 kW and that is used in closed loop systems must have an energy efficiency index (EEI) not more than 0.27 calculated in accordance with European Union Commission Regulation No. 622/2012.\n(6) Other pumps — Pumps that are in accordance with Articles 1 and 2 of European Union Commission Regulation No. 547/2012 must have a minimum efficiency index (MEI) of 0.4 or more when calculated in accordance with European Union Commission Regulation No. 547/2012.\n(7) Pipework — Straight segments of pipework along the index run, forming part of an air-conditioning system—\nin pipework systems that do not have branches and have the same flow rate throughout the entire pipe network, must achieve an average pressure drop of not more than—\nfor constant flow systems, the values nominated in Table J6D8a; or\nfor variable flow systems, the values nominated in Table J6D8b; or\nin any other pipework system, must achieve an average pressure drop of not more than—\nfor constant flow systems, the values nominated in Table J6D8c; or\nfor variable flow systems, the values nominated in Table J6D8d.\n(8) The requirements of (7) do not apply—\nto valves and fittings; or\nwhere the smallest pipe size compliant with (7) results in a velocity of 0.7 m/s or less at design flow.\nTable J6D8a Maximum pipework pressure drop – Non-distributive constant flow systems\nNominal pipe diameter (mm)\nMaximum pressure drop in systems operating 5000 hours/annum or less (Pa/m)\nMaximum pressure drop in systems operating more than 5000 hours/annum (Pa/m)\nNot more than 20\n400\n400\n25\n400\n400\n32\n400\n400\n40\n400\n400\n50\n400\n350\n65\n400\n350\n80\n400\n350\n100\n400\n200\n125\n400\n200\n150 or more\n400\n200\nTable J6D8b Maximum pipework pressure drop – Non-distributive variable flow systems\nNominal pipe diameter (mm)\nMaximum pressure drop in systems operating 5000 hours/annum or less (Pa/m)\nMaximum pressure drop in systems operating more than 5000 hours/annum (Pa/m)\nNot more than 20\n400\n400\n25\n400\n400\n32\n400\n400\n40\n400\n400\n50\n400\n400\n65\n400\n400\n80\n400\n400\n100\n400\n300\n125\n400\n300\n150 or more\n400\n300\nTable J6D8c Maximum pipework pressure drop – Distributive constant flow systems\nNominal pipe diameter (mm)\nMaximum pressure drop in systems operating 2000 hours/annum or less (Pa/m)\nMaximum pressure drop in systems operating between 2000 hours/annum and 5000 hrs/yr (Pa/m)\nMaximum pressure drop in systems operating more than 5000 hours/annum (Pa/m)\nNot more than 20\n400\n300\n150\n25\n400\n220\n100\n32\n400\n220\n100\n40\n400\n220\n100\n50\n400\n220\n100\n65\n400\n400\n170\n80\n400\n400\n170\n100\n400\n400\n170\n125\n400\n400\n170\n150 or more\n400\n400\n170\nTable J6D8d Maximum pipework pressure drop – Distributive variable flow systems\nNominal pipe diameter (mm)\nMaximum pressure drop in systems operating 5000 hours/annum or less (Pa/m)\nMaximum pressure drop in systems operating more than 5000 hours/annum (Pa/m)\nNot more than 20\n400\n250\n25\n400\n180\n32\n400\n180\n40\n400\n180\n50\n400\n180\n65\n400\n300\n80\n400\n300\n100\n400\n300\n125\n400\n300\n150 or more\n400\n300","g":"/ncc/j6d8","a19":["J5.7"]},{"c":"Table J6D9a","t":"Piping — Minimum insulation R-Value","p":"Part J6 Air-conditioning and ventilation","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j6-air-conditioning-and-ventilation#_e04d2918-4af8-4338-9726-edc52eb14247","x":"Fluid temperature | Minimum insulation  R-Value nominal pipe diameter ≤ 40 mm | Minimum insulation R-Value — nominal pipe diameter > 40 mm and ≤ 80 mm | Minimum insulation R-Value — nominal pipe diameter between > 80 mm and ≤ 150 mm | Minimum insulation R-Value — nominal pipe diameter > 150 mm\nLow temperature chilled — ≤ 2°C | 1.3 | 1.7 | 2.0 | 2.7\nChilled — > 2°C but ≤ 20°C | 1.0 | 1.5 | 2.0 | 2.0\nHeated — > 30°C but ≤ 85°C | 1.7 | 1.7 | 1.7 | 1.7\nHigh temperature heated — > 85°C | 2.7 | 2.7 | 2.7 | 2.7\nTable Notes\nThe minimum required R-Value may be halved for piping penetrating a structural member.","tb":"J6D9","g":"/ncc/table-j6d9a"},{"c":"Table J6D9b","t":"Vessels, heat exchangers and tanks — Minimum insulation R-Value","p":"Part J6 Air-conditioning and ventilation","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j6-air-conditioning-and-ventilation#_d49777ab-bf19-4fb7-ae60-ff3102d95951","x":"Fluid temperature range | Minimum insulation R-Value\nLow temperature chilled — ≤ 2°C | 2.7\nChilled — > 2°C but ≤ 20°C | 1.8\nHeated — > 30°C but ≤ 85°C | 3.0\nHigh temperature heated — > 85°C | 3.0","tb":"J6D9","g":"/ncc/table-j6d9b"},{"c":"J6D9","t":"Pipework insulation","p":"Part J6 Air-conditioning and ventilation","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j6-air-conditioning-and-ventilation#J6D9","x":"(1) Piping, vessels, heat exchangers and tanks containing heating or cooling fluid, where the fluid is held at a heated or cooled temperature, that are part of an air-conditioning system, other than within appliances covered by MEPS, must be provided with insulation—\ncomplying with AS/NZS 4859.1; and\nfor piping of heating and cooling fluids, having an insulation R-Value in accordance with Table J6D9a; and\nfor vessels, heat exchangers or tanks, having an insulation R-Value in accordance with Table J6D9b; and\nfor refill or pressure relief piping, having an insulation R-Value equal to the required insulation R-Value of the connected pipe, vessel or tank within 500 mm of the connection.\n(2) Insulation must—\nbe protected against the effects of weather and sunlight; and\nbe able to withstand the temperatures within the piping, vessel, heat exchanger or tank.\n(3) Insulation provided to piping, vessels, heat exchangers or tanks containing cooling fluid must be protected by a vapour barrier on the outside of the insulation.\n(4) The requirements of (1) and (2) do not apply to piping, vessels or heat exchangers—\nlocated within the only or last room served by the system and downstream of the control device for the regulation of heating or cooling service to that room; or\nencased within a concrete slab or panel which is part of a heating or cooling system; or\nsupplied as an integral part of a chiller, boiler or unitary air-conditioner complying with the requirements of J6D10, J6D11 and J6D12; or\ninside an air-handling unit, fan-coil unit, or the like.\n(5) For the purposes of (1), (2), (3) and (4)—\nheating fluids include heated water, steam and condensate; and\ncooling fluids include refrigerant, chilled water, brines and glycol mixtures, but do not include condenser cooling water.\nTable J6D9a Piping — Minimum insulation R-Value\nFluid temperature\nMinimum insulation  R-Value nominal pipe diameter ≤ 40 mm\nMinimum insulation R-Value — nominal pipe diameter > 40 mm and ≤ 80 mm\nMinimum insulation R-Value — nominal pipe diameter between > 80 mm and ≤ 150 mm\nMinimum insulation R-Value — nominal pipe diameter > 150 mm\nLow temperature chilled — ≤ 2°C\n1.3\n1.7\n2.0\n2.7\nChilled — > 2°C but ≤ 20°C\n1.0\n1.5\n2.0\n2.0\nHeated — > 30°C but ≤ 85°C\n1.7\n1.7\n1.7\n1.7\nHigh temperature heated — > 85°C\n2.7\n2.7\n2.7\n2.7\nTable Notes\nThe minimum required R-Value may be halved for piping penetrating a structural member.\nTable J6D9b Vessels, heat exchangers and tanks — Minimum insulation R-Value\nFluid temperature range\nMinimum insulation R-Value\nLow temperature chilled — ≤ 2°C\n2.7\nChilled — > 2°C but ≤ 20°C\n1.8\nHeated — > 30°C but ≤ 85°C\n3.0\nHigh temperature heated — > 85°C\n3.0","g":"/ncc/j6d9","a19":["J5.8"]},{"c":"Table J6D10","t":"Maximum electric resistance heating capacity","p":"Part J6 Air-conditioning and ventilation","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j6-air-conditioning-and-ventilation#_d1dc01c9-4d94-4dda-9208-e2384c21efc7","x":"Floor area of the conditioned space | W/m2 of floor area in climate zone 3 | W/m2 of floor area in climate zone 4 | W/m2 of floor area in climate zone 5 | W/m2 of floor area in climate zone 6 | W/m2 of floor area in climate zone 7\n≤ 500 m2 | 50 | 60 | 55 | 65 | 70\n> 500 m2 | 40 | 50 | 45 | 55 | 60","tb":"J6D10","g":"/ncc/table-j6d10"},{"c":"J6D10","t":"Space heating","p":"Part J6 Air-conditioning and ventilation","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j6-air-conditioning-and-ventilation#J6D10","x":"(1) A heater used for air-conditioning or as part of an air-conditioning system must be—\na solar heater; or\na gas heater; or\na heat pump heater or 4-pipe chiller; or\na heater using reclaimed heat from another process such as reject heat from a refrigeration plant; or\nan electric resistance heater if—\nthe heating capacity is not more than—\n40 W/m2 of the floor area of the conditioned space in climate zones 1 or 2; or\nthe value specified in Table J6D10 in climate zones 3 to 8; or\nthe annual energy consumption for heating is not more than 15 kWh/m2 of the floor area of the conditioned space in climate zones 1, 2, 3, 4 and 5; or\nthe in-duct heater complies with J6D3(1)(c)(iv);or\nany combination of (a) to (e).\n(2) An electric resistance heater may be used for heating a bathroom if—\nthe heating capacity is not more than 1.2 kW; and\nthe heater has a time switch configured to deactivate the heater after a run-on period not more than 15 minutes from when there are no occupants in the space served.\n(3) A fixed heating or cooling appliance that moderates the temperature of an outdoor space must—\nbe a radiant heater or evaporative cooler; and\nbe configured to automatically shut down when—\nthere are no occupants in the space served; or\na period of one hour has elapsed since the last activation; or\nthe space served has reached the design temperature for heating; or\nthe space served has reached the design temperature for 30 minutes for cooling.\n(4) A gas water heater, that is used as part of an air-conditioning system, must achieve a minimum gross thermal efficiency of 90%.\n(5) A building with gas space heating must be provided with—\nreserved electrical capacity sufficient to support future installation of—\nan electric resistance space heating system with a heating capacity of not more than the value specified in J6D10(1)(e)(i) or (ii); or\nair-source heat pump water heating equipment assuming a nominal coefficient of performance of 3.25; or\na combination of (i) and (ii); and\nreserved space within the main electrical distribution board, labelled accordingly, sized to facilitate future installation of switchgear and electrical supply for electric space heating equipment sized in accordance with (a); and\nreserved space in the electrical riser or supply pathway for future electric space heating equipment sized in accordance with (a).\n(6) Where reserved capacity for air-source heat pump water heating equipment is required by (5), the building must be provided with—\nreserved space for an open-roofed plant room or rooftop plant area with—\nan area of at least 36 m² plus 0.04 m²/kW of heating capacity to facilitate future installation of air-source heat pump water heating equipment; and\nsufficient ventilation openings to achieve airflow of at least 100 L/s per kW of heating capacity to facilitate future air-source heat pump equipment, with no recirculation of air; and\nconnection to the space heating hot water system; and\na hot water circulation system that can deliver the design heating load at a peak temperature of less than 50°C.\n(7) Capacity and space required by (5) and (6) must be sufficient to serve all of the conditioned space with the same design load used to specify the gas space heater equipment.\n(8) A connected group of one or more air-source heat pump water heaters, including 4-pipe chillers used as part of an air-conditioning system, must—\nwhen operating in heating mode have a capacity-weighted average coefficient of performance of not less than 3.14 at intermediate temperature and standard rating conditions as specified in Table 13 of EN 14511-2; and\nwhen operating in cooling mode—\nhave a capacity-weighted average energy efficiency ratio at full load of not less than—\n2.9 when determined in accordance with AHRI 551/591; or\n2.9 when determined at the standard rating conditions specified in Table 16 of EN 14511-2; and\nhave a capacity-weighted average part load performance assessed based on—\nintegrated part load value of not less than 4.69 when determined in accordance with AHRI 551/591; or\nSeasonal Energy Efficiency Ratio of 3.91 when determined in accordance with methods of Part 5 of EN 14825, at the standard part load conditions defined in Part 4 of EN 14825.\n(9) The capacity-weighted average of each efficiency metric in (8) must be calculated in accordance with the following formula:\n[formula] where—\n[formula] = the number of heat pump water heaters in the group; and\n[formula] = the capacity of each heater, [formula] , in either heating or cooling mode as applicable; and\n[formula] = the rated coefficient of performance, energy efficiency ratio, or integrated part load value of each heater, [formula] as applicable.\nTable J6D10 Maximum electric resistance heating capacity\nFloor area of the conditioned space\nW/m2 of floor area in climate zone 3\nW/m2 of floor area in climate zone 4\nW/m2 of floor area in climate zone 5\nW/m2 of floor area in climate zone 6\nW/m2 of floor area in climate zone 7\n≤ 500 m2\n50\n60\n55\n65\n70\n> 500 m2\n40\n50\n45\n55\n60","g":"/ncc/j6d10","a19":["J5.9"]},{"c":"Table J6D11a","t":"Minimum energy efficiency ratio or integrated part load value for water-cooled refrigerant chillers other than 4-pipe chillers","p":"Part J6 Air-conditioning and ventilation","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j6-air-conditioning-and-ventilation#_75fc0156-9005-4536-91c5-1f164252f4c0","x":"Climate zone | Chiller rated cooling capacity kW | Full load energy efficiency ratio | Integrated part load value\n1, 2 | 0 to 250 | 5.0 | —\n1, 2 | > 250 to ≤ 500 | 5.6 | —\n1, 2 | > 500 to ≤ 1,500 | 6.1 | —\n1, 2 | > 1,500 | 6.5 | —\n3 | 0 to 250 | 5.0 | 6.2\n3 | > 250 to ≤ 500 | 5.8 | 8.3\n3 | > 500 to ≤ 1,500 | 6.0 | 10.4\n3 | > 1,500 | 6.3 | 11.4\n4, 5, 6, 7 or 8 | 0 to 250 | 5.0 | 6.2\n4, 5, 6, 7 or 8 | > 250 to ≤ 500 | 5.5 | 8.3\n4, 5, 6, 7 or 8 | > 500 to ≤ 1,500 | 6.0 | 10.4\n4, 5, 6, 7 or 8 | > 1,500 | 6.3 | 11.4","tb":"J6D11","g":"/ncc/table-j6d11a"},{"c":"Table J6D11b","t":"Minimum climate specific part load value for a connected group of water-cooled chiller plant","p":"Part J6 Air-conditioning and ventilation","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j6-air-conditioning-and-ventilation#_e89325a0-4686-4e99-b2d4-d206499eec16","x":"Climate zone | Design load not greater than 450 kW | Design load greater than 450 kW to 900 kW | Design load greater than 900 kW to 2,400 kW | Design load greater than 2,400 kW\n1 | 5.2 | 6.2 | 6.4 | 6.8\n2 | 5.7 | 7.0 | 7.8 | 8.4\n3 | 6.1 | 8.2 | 9.5 | 10.5\n4 | 6.2 | 8.1 | 9.4 | 10.7\n5 | 5.9 | 7.2 | 8.1 | 9.2\n6 | 6.3 | 8.3 | 9.5 | 10.7\n7 | 6.2 | 8.2 | 9.4 | 10.9\n8 | 6.4 | 9.0 | 10.6 | 12.8","tb":"J6D11","g":"/ncc/table-j6d11b"},{"c":"Table J6D11c","t":"Minimum climate specific part load value for a connected group of air-cooled chiller plant","p":"Part J6 Air-conditioning and ventilation","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j6-air-conditioning-and-ventilation#_fd3dc8c8-9367-4a7c-af54-b645322dda6c","x":"Climate zone | Design load not greater than 900 kW | Design load greater than 900 kW\n1 | 4.1 | 3.9\n2 | 4.8 | 4.5\n3 | 4.3 | 4.1\n4 | 4.9 | 4.5\n5 | 5.1 | 4.8\n6 | 5.4 | 5.0\n7 | 5.2 | 4.9\n8 | 5.6 | 5.5","tb":"J6D11","g":"/ncc/table-j6d11c"},{"c":"J6D11","t":"Refrigerant chillers","p":"Part J6 Air-conditioning and ventilation","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j6-air-conditioning-and-ventilation#J6D11","x":"(1) Refrigerant chillers must—\nindividually, comply with (2); or\ncollectively, comply with (3).\n(2) When assessed in accordance with AHRI 551/591, a chiller must—\nwhere air-cooled—\nin climate zones 1 or 3, achieve a full load operation energy efficiency ratio of not less than 3.1; and\nin climate zones 2, 4, 5, 6 or 7 achieve a full load operation energy efficiency ratio and an integrated part load value such that the sum of the two is not less than—\n8.1, where the rated cooling capacity of the chiller is not greater than 550 kW; and\n8.5, where the rated cooling capacity of the chiller is greater than 550 kW; and\nin climate zone 8, achieve an integrated part load value of not less than—\n5.1, where the rated cooling capacity of the chiller is not greater than 550 kW; or\n5.4, where the rated cooling capacity of the chiller is greater than 550 kW; and\nwhere water-cooled—\nin climate zones 1 or 2, achieve full load operation energy efficiency ratio of not less than the value specified in Table J6D11a; and\nin climate zones 3 to 8, achieve a full load operation energy efficiency ratio and an integrated part load value such that the sum of the two is not less than the sum of the full load and integrated part load values specified in Table J6D11a, as applicable.\n(3) A connected group of one or more refrigerant chillers, used as part of an air-conditioning system, must achieve a climate specific part load value, determined in accordance with Specification 47, greater than—\nthe applicable value specified in Table J6D11b, where all chillers in the group are water-cooled; or\nthe applicable value specified in Table J6D11c, where all chillers in the group are air-cooled; or\nthe average of the applicable values specified in Table J6D11b and Table J6D11c weighted according to the total full-load capacity of the chillers, where the group has both water-cooled and air-cooled chillers.\n(4) The requirements of (1), (2) and (3) do not apply to—\n4-pipe chillers; or\nair-source heat pump water heaters.\nTable J6D11a Minimum energy efficiency ratio or integrated part load value for water-cooled refrigerant chillers other than 4-pipe chillers\nClimate zone\nChiller rated cooling capacity kW\nFull load energy efficiency ratio\nIntegrated part load value\n1, 2\n0 to 250\n5.0\n—\n1, 2\n> 250 to ≤ 500\n5.6\n—\n1, 2\n> 500 to ≤ 1,500\n6.1\n—\n1, 2\n> 1,500\n6.5\n—\n3\n0 to 250\n5.0\n6.2\n3\n> 250 to ≤ 500\n5.8\n8.3\n3\n> 500 to ≤ 1,500\n6.0\n10.4\n3\n> 1,500\n6.3\n11.4\n4, 5, 6, 7 or 8\n0 to 250\n5.0\n6.2\n4, 5, 6, 7 or 8\n> 250 to ≤ 500\n5.5\n8.3\n4, 5, 6, 7 or 8\n> 500 to ≤ 1,500\n6.0\n10.4\n4, 5, 6, 7 or 8\n> 1,500\n6.3\n11.4\nTable J6D11b Minimum climate specific part load value for a connected group of water-cooled chiller plant\nClimate zone\nDesign load not greater than 450 kW\nDesign load greater than 450 kW to 900 kW\nDesign load greater than 900 kW to 2,400 kW\nDesign load greater than 2,400 kW\n1\n5.2\n6.2\n6.4\n6.8\n2\n5.7\n7.0\n7.8\n8.4\n3\n6.1\n8.2\n9.5\n10.5\n4\n6.2\n8.1\n9.4\n10.7\n5\n5.9\n7.2\n8.1\n9.2\n6\n6.3\n8.3\n9.5\n10.7\n7\n6.2\n8.2\n9.4\n10.9\n8\n6.4\n9.0\n10.6\n12.8\nTable J6D11c Minimum climate specific part load value for a connected group of air-cooled chiller plant\nClimate zone\nDesign load not greater than 900 kW\nDesign load greater than 900 kW\n1\n4.1\n3.9\n2\n4.8\n4.5\n3\n4.3\n4.1\n4\n4.9\n4.5\n5\n5.1\n4.8\n6\n5.4\n5.0\n7\n5.2\n4.9\n8\n5.6\n5.5","g":"/ncc/j6d11","a19":["J5.10"]},{"c":"Table J6D12a","t":"Nominal minimum energy efficiency ratio figures for air-cooled unitary air-conditioning systems","p":"Part J6 Air-conditioning and ventilation","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j6-air-conditioning-and-ventilation#_cc311599-f2fc-40dd-8083-172000b4222a","x":"Rated cooling capacity | Unitary systems other than variable refrigerant flow units | Variable refrigerant flow units\n≤ 39 kW | 3.3 | 3.8\n> 39 kW | 3.1 | 3.4","tb":"J6D12","g":"/ncc/table-j6d12a"},{"c":"Table J6D12b","t":"Nominal minimum TCSPF figures for air-cooled unitary air-conditioning systems","p":"Part J6 Air-conditioning and ventilation","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j6-air-conditioning-and-ventilation#_a4857cbc-3c64-4357-bc3a-968f1a8f2ab3","x":"Rated cooling capacity | Unitary systems other than variable refrigerant flow units\n≤ 30 kW | 3.6\n> 30 kW | 3.5","tb":"J6D12","g":"/ncc/table-j6d12b"},{"c":"J6D12","t":"Unitary air-conditioning equipment","p":"Part J6 Air-conditioning and ventilation","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j6-air-conditioning-and-ventilation#J6D12","x":"(1) Water-to-air unitary air-conditioners with a rated capacity greater than or equal to 65 kW, including packaged air-conditioners, split systems, and variable refrigerant flow units, must have a minimum energy efficiency ratio of 4.0 Wr/Winput power for cooling when tested in accordance with AS/NZS ISO 13256.1 at test condition C3, where input power includes both compressor and fan input power.\n(2) Assessed individually or collectively, a building’s air-cooled unitary air-conditioning equipment, including packaged air-conditioners, split systems, and variable refrigerant flow units, must have a weighted efficiency index greater than 1—\ncalculated using the following formula, based on the energy efficiency ratio, [formula] , where—\n[formula] = the weighted efficiency index of the unitary air-conditioners serving a building, assessed based on their rated Energy Efficiency Ratios; and\nfor each air-conditioner, [formula] —\n[formula] = the tested energy efficiency ratio, determined in accordance with MEPS; and\n[formula] = the rated cooling capacity determined in accordance with MEPS; and\n[formula] = the applicable nominal minimum energy efficiency ratio in Table J6D12a; or\ncalculated using the following formula, based on the Total Cooling Seasonal Performance Factor, [formula] , where—\n[formula] = the weighted efficiency index of the unitary air-conditioners serving a building, assessed based on their rated Total Cooling Seasonal Performance Factors; and\nfor each air-conditioner, [formula] —\n[formula] = the mixed zone Total Cooling Seasonal Performance Factor, determined in accordance with MEPS for the commercial based use of the product; and\n[formula] = the rated cooling capacity determined in accordance with MEPS; and\n[formula] = the applicable nominal minimum energy efficiency ratio in Table J6D12b.\n(3) Where the weighted efficiency index contribution of an air-conditioner is assessed using the formula at (2)(a), air-cooled unitary air-conditioners, including packaged air-conditioners, split systems and variable refrigerant flow units, must have—\nvariable speed outdoor fans; and\nat least one—\ndigital scroll compressor; or\ninverter driven compressor.\n(4) The compressor required by 3(b) must be sized sufficiently to allow the unit to modulate across 50% to 100% of its rated cooling capacity.\n(5) The requirements of (2) to (4) do not apply to—\nunitary air-conditioners with a rated cooling capacity of less than 10 kW; or\nunitary air-conditioners that serve only a Class 4 part of a building.\nTable J6D12a Nominal minimum energy efficiency ratio figures for air-cooled unitary air-conditioning systems\nRated cooling capacity\nUnitary systems other than variable refrigerant flow units\nVariable refrigerant flow units\n≤ 39 kW\n3.3\n3.8\n> 39 kW\n3.1\n3.4\nTable J6D12b Nominal minimum TCSPF figures for air-cooled unitary air-conditioning systems\nRated cooling capacity\nUnitary systems other than variable refrigerant flow units\n≤ 30 kW\n3.6\n> 30 kW\n3.5","g":"/ncc/j6d12","a19":["J5.11"]},{"c":"Table J6D13","t":"Maximum fan motor power – Cooling towers, closed circuit coolers and evaporative condensers","p":"Part J6 Air-conditioning and ventilation","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j6-air-conditioning-and-ventilation#_c6671383-77d4-45d2-9708-c7180fd3256a","x":"Type | Cooling tower maximum fan motor input power (W/kW) | Closed circuit cooler maximum fan motor input power (W/kW) | Evaporative condenser maximum fan motor input power (W/kW)\nInduced draft | 10.4 | 16.9 | 11.0\nForced draft | 19.5 | Note | 11.0\nTable Notes\nA closed circuit, forced draft cooling tower must not be used.","tb":"J6D13","g":"/ncc/table-j6d13"},{"c":"J6D13","t":"Heat rejection equipment","p":"Part J6 Air-conditioning and ventilation","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j6-air-conditioning-and-ventilation#J6D13","x":"(1) The motor rated power of a fan in a cooling tower, closed circuit cooler or evaporative condenser must not exceed the allowances in Table J6D13.\n(2) The fan in an air-cooled condenser must have a motor rated power of not more than 42 W for each kW of heat rejected from the refrigerant when determined in accordance with AHRI 460.\n(3) A fan with a three-phase motor in heat rejection equipment must be capable of variable speed operation.\n(4) The requirements of (2) and (3) do not apply to—\na fan in a refrigerant chiller of an air-conditioning system that complies with J6D11; and\nfans in unitary air-conditioning equipment, such as a packaged air-conditioners, a split system or a variable refrigerant flow unit that complies with J6D12; and\na fan in a 4-pipe chiller or air source heat pump water heater that complies with J6D10 (8).\nTable J6D13 Maximum fan motor power – Cooling towers, closed circuit coolers and evaporative condensers\nType\nCooling tower maximum fan motor input power (W/kW)\nClosed circuit cooler maximum fan motor input power (W/kW)\nEvaporative condenser maximum fan motor input power (W/kW)\nInduced draft\n10.4\n16.9\n11.0\nForced draft\n19.5\nNote\n11.0\nTable Notes\nA closed circuit, forced draft cooling tower must not be used.","g":"/ncc/j6d13","a19":["J5.12"]},{"c":"J7D1","t":"Deemed-to-Satisfy Provisions","p":"Part J7 Artificial lighting and power","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j7-artificial-lighting-and-power#J7D1","x":"(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements J1P1 to J1P4 are satisfied by complying with—\nJ2D2; and\nJ3D2 to J3D15; and\nJ4D2 to J4D7; and\nJ5D2 to J5D8; and\nJ6D2 to J6D13; and\nJ7D2 to J7D9; and\nJ8D2 to J8D5; and\nJ9D2 to J9D5.\n(2) Where a Performance Solution is proposed, the relevant Performance Requirements must be determined in accordance with A2G2(3) and A2G4(3) as applicable.","g":"/ncc/j7d1","a19":["J6.0"]},{"c":"J7D2","t":"Application of Part","p":"Part J7 Artificial lighting and power","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j7-artificial-lighting-and-power#J7D2","x":"J7D3, J7D4 and J7D6(1)(b) do not apply to a Class 8 electricity network substation.","g":"/ncc/j7d2","a19":["J6.1","NSW J(A)4.1"]},{"c":"Table J7D3a","t":"Maximum illumination power density","p":"Part J7 Artificial lighting and power","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j7-artificial-lighting-and-power#_85a815c2-efd3-4bcc-8519-1c7718d68ce0","x":"Space | Maximum illumination power density (W/m2)\nAuditorium, church and public hall | 8\nBoard room and conference room | 5\nCarpark - general | 2\nCarpark - entry zone (first 15 m of travel) during the daytime | 11.5\nCarpark - entry zone (next 4 m of travel) during the day | 2.5\nCarpark - entry zone (first 20 m of travel) during night time | 2.5\nCommon rooms, spaces and corridors in a Class 2 building | 4.5\nControl room, switch room and the like - intermittent monitoring | 3\nControl room, switch room and the like - constant monitoring | 4.5\nCorridors | 5\nCourtroom | 4.5\nDormitory of a Class 3 building used for sleeping only | 3\nDormitory of a Class 3 building used for sleeping and study | 4\nEntry lobby from outside the building | 9\nHealth-care - infants' and children's wards and emergency department | 4\nHealth-care - examination room | 4.5\nHealth-care - examination room in intensive care and high dependency ward | 6\nHealth-care - all other patient care areas including wards and corridors | 2.5\nKitchen and food preparation area | 4\nLaboratory - artificially lit to an ambient level of 400 lx or more | 6\nLibrary - stack and shelving area | 2.5\nLibrary - reading room and general areas | 4.5\nLounge area for communal use in a Class 3 or 9c building | 4.5\nMuseum and gallery - circulation, cleaning and service lighting | 2.5\nOffice - artificially lit to an ambient level of 200 lx or more | 4.5\nOffice - artificially lit to an ambient level of less than 200 lx | 2.5\nPlant room where an average of 160 lx vertical illuminance is required on a vertical panel such as in switch rooms | 4\nPlant rooms with a horizontal illuminance target of 80 lx | 2\nRestaurant, café, bar, hotel lounge and a space for the serving and consumption of food or drinks | 14\nRetail space including a museum and gallery whose purpose is the sale of objects | 14\nSchool - general purpose learning areas and tutorial rooms | 4.5\nSole-occupancy unit of a Class 3 or 9c building | 5\nStorage | 1.5\nService area, cleaner's room and the like | 1.5\nToilet, locker room, staff room, rest room and the like | 3\nWholesale storage area with a vertical illuminance target of 160 lx | 4\nStairways, including fire-isolated stairways | 2\nLift cars | 5.5\nTable Notes\nIn areas not listed above, the maximum illumination power density is—\nfor an illuminance not more than 80 lx, 2 W/m2; and\nfor an illuminance more than 80 lx and not more than 160 lx, 2.5 W/m2; and\nfor an illuminance more than 160 lx and not more than 240 lx, 3 W/m2; and\nfor an illuminance more than 240 lx and not more than 320 lx, 4.5 W/m2; and\nfor an illuminance more than 320 lx and not more than 400 lx, 6 W/m2; and\nfor an illuminance more than 400 lx and not more than 600 lx, 10 W/m2; and\nfor an illuminance more than 600 lx and not more than 800 lx, 11.5 W/m2.\nFor enclosed spaces with a Room Aspect Ratio of less than 1.5, the maximum illumination power density may be increased by dividing it by an adjustment factor for room aspect which is 0.5 + (Room Aspect Ratio/3).\nThe Room Aspect Ratio of the enclosed space is determined by the formula: A/(H x C), where—\nA is the area of the enclosed space; and\nH is the height of the space measured from the floor to the highest part of the ceiling; and\nC is the perimeter of the enclosed space at floor level.\nIn addition to 2, the maximum illumination power density may be increased by dividing it by the illumination power density adjustment factor in Table J7D3b and Table J7D3c.\nCirculation spaces are included in the allowances listed in this table.","tb":"J7D3","g":"/ncc/table-j7d3a"},{"c":"Table J7D3b","t":"Illumination power density adjustment factor for a control device","p":"Part J7 Artificial lighting and power","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j7-artificial-lighting-and-power#_52b16ae7-8ca7-4fff-b74e-1e59952ef3ed","x":"Item Notes 1 and 2 | Description | illumination power density adjustment factor\nDemand-operated controls | In a toilet or change room, other than a public toilet, in a Class 6 building | 0.4\nDemand-operated controls | Where a group of light fittings serving less than 100 m2 is controlled by one or more detectors | 0.6\nDemand-operated controls | Where a group of light fittings serving 100 m2 or more is controlled by one or more detectors | 0.7\nProgrammable dimming system Note 3 | Where not less than 75% of the area of a space is controlled by programmable dimmers | 0.85\nFixed dimming Notes 3 and 4 | All fittings with fixed dimming | Whichever is greater of (a) 0.5; or (b) 0.2+0.8L where L = the illuminance turndown for the fixed dimming.\nLumen depreciation dimming Note 3 | All fittings with lumen depreciation dimming | 0.85\nTwo stage sensor - equipped lights with minimum power of 30 % of peak power or less | Fire stairs and other spaces not used for regular transit | 0.4\nTwo stage sensor - equipped lights with minimum power of 30% of peak power or less | Transitory spaces in regular use or in a carpark | 0.7\nDaylight sensor and dynamic lighting control device - dimmed or stepped switching of lights adjacent windows Notes 3 and 5 | In a Class 5, 6, 7, 8 or 9b building or a Class 9a building, other than a ward area, where the lights are adjacent windows, other than roof lights, for a distance from the window equal to the depth of the floor to window head height | 0.5 Note 3\nDaylight sensor and dynamic lighting control device - dimmed or stepped switching of lights adjacent windows Notes 3 and 5 | Serving a Class 3 or 9c building, or a Class 9a ward area, where the lights are adjacent windows, other than roof lights, for a distance from the window equal to the depth of the floor to window head height | 0.75 Note 3\nDaylight sensor and dynamic lighting control device - dimmed or stepped switching of lights adjacent windows Notes 3 and 5 | In a Class 5, 6, 7, 8 or 9b building or a Class 9a building, other than a ward area, where the lights are adjacent roof lights | 0.6 Note 3\nDaylight sensor and dynamic lighting control device - dimmed or stepped switching of lights adjacent windows Notes 3 and 5 | In a Class 3 or 9c building, or a Class 9a ward area, where the lights are adjacent roof lights | 0.8 Note 3\nTable Notes\nA maximum of two illumination power density adjustment factors for a control device can be applied to an area.\nWhere more than one illumination power density adjustment factor (other than for room aspect) applies to an area, they are to be combined using the following formula: , where—\nis the lowest applicable illumination power density adjustment factor; and\nis the second lowest applicable illumination power density adjustment factor.\nThe adjustment factor does not apply to tungsten, halogen or other incandescent sources.\nIncludes luminaires with a pre-programmed function which provides dimming from ON to OFF (one-stage dimming).\nFor lighting controlled by daylight sensors, the illumination power density adjustment factor is only applied between 8:00 am and 7:00 pm.","tb":"J7D3","g":"/ncc/table-j7d3b"},{"c":"Table J7D3c","t":"Illumination power density adjustment factor for light colour","p":"Part J7 Artificial lighting and power","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j7-artificial-lighting-and-power#_4db0f47b-2b14-4fd9-afaa-889cb5f5558f","x":"Light source | Description | Illumination power density adjustment factor\nCRI ≥ 90 | Where lighting with good colour rendering is used | 0.9\nCCT ≤ 3500 K Note | Where lighting with a warm appearance is used | 0.8\nCCT ≥ 4500 K | Where lighting with a cool appearance is used | 1.1\nTable Notes\nIncludes luminaires that can adjust their CCT to 3500 K or below.","tb":"J7D3","g":"/ncc/table-j7d3c"},{"c":"J7D3","t":"Artificial lighting","p":"Part J7 Artificial lighting and power","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j7-artificial-lighting-and-power#J7D3","x":"(1) In a Class 4 part of a building—\nthe lamp power density or illumination power density of artificial lighting must not exceed the allowance of—\n5 W/m2 within a sole-occupancy unit; and\n4 W/m2 on a verandah, balcony or the like attached to a sole-occupancy unit; and\nthe illumination power density allowance in (a) may be increased by dividing it by the illumination power density adjustment factor for a control device in Table J7D3b as applicable; and\nwhen designing the lamp power density or illumination power density, the power of the proposed installation must be used rather than nominal allowances for exposed batten holders or luminaires; and\nhalogen lamps must be separately switched from fluorescent lamps.\n(2) In a building other than a Class 4 part of a building—\nfor artificial lighting, the aggregate design illumination power load must not exceed the sum of the allowances obtained by multiplying the area of each space by the maximum illumination power density in Table J7D3a; and\nthe aggregate design illumination power load in (a) is the sum of the design illumination power loads in each of the spaces served; and\nwhere there are multiple lighting systems serving the same space, the design illumination power load for (b) is—\nthe total illumination power load of all systems; or\nwhere a control system permits only one system to operate at a time based on the highest illumination power load; or determined by the formula— [formula] In the formula at (c)(ii)—\n[formula] = the highest illumination power load; and\n[formula] = the time for which the maximum illumination power load will occur, expressed as a percentage; and\n[formula] = the predominant illumination power load.\n(3) The requirements of (1) and (2) do not apply to the following:\nEmergency lighting provided in accordance with Part E4, including dedicated light sources for photoluminescent exit signs required by S25C3(a).\nSignage, display lighting within cabinets and display cases that are fixed in place.\nLighting for accommodation within the residential part of a detention centre.\nA heater where the heater also emits light, such as in bathrooms.\nLighting of a specialist process nature such as in a surgical operating theatre, fume cupboard or clean workstation.\nLighting of performances such as theatrical or sporting.\nLighting for the permanent display and preservation of works of art or objects in a museum or gallery other than for retail sale, purchase or auction.\nLighting installed solely to provide photosynthetically active radiation for indoor plant growth on green walls and the like.\n(4) For the purposes of Table J7D3b, the following control devices must comply with Specification 40:\nDemand-operated controls.\nDaylight sensors and dynamic lighting control devices.\nTable J7D3a Maximum illumination power density\nSpace\nMaximum illumination power density (W/m2)\nAuditorium, church and public hall\n8\nBoard room and conference room\n5\nCarpark - general\n2\nCarpark - entry zone (first 15 m of travel) during the daytime\n11.5\nCarpark - entry zone (next 4 m of travel) during the day\n2.5\nCarpark - entry zone (first 20 m of travel) during night time\n2.5\nCommon rooms, spaces and corridors in a Class 2 building\n4.5\nControl room, switch room and the like - intermittent monitoring\n3\nControl room, switch room and the like - constant monitoring\n4.5\nCorridors\n5\nCourtroom\n4.5\nDormitory of a Class 3 building used for sleeping only\n3\nDormitory of a Class 3 building used for sleeping and study\n4\nEntry lobby from outside the building\n9\nHealth-care - infants' and children's wards and emergency department\n4\nHealth-care - examination room\n4.5\nHealth-care - examination room in intensive care and high dependency ward\n6\nHealth-care - all other patient care areas including wards and corridors\n2.5\nKitchen and food preparation area\n4\nLaboratory - artificially lit to an ambient level of 400 lx or more\n6\nLibrary - stack and shelving area\n2.5\nLibrary - reading room and general areas\n4.5\nLounge area for communal use in a Class 3 or 9c building\n4.5\nMuseum and gallery - circulation, cleaning and service lighting\n2.5\nOffice - artificially lit to an ambient level of 200 lx or more\n4.5\nOffice - artificially lit to an ambient level of less than 200 lx\n2.5\nPlant room where an average of 160 lx vertical illuminance is required on a vertical panel such as in switch rooms\n4\nPlant rooms with a horizontal illuminance target of 80 lx\n2\nRestaurant, café, bar, hotel lounge and a space for the serving and consumption of food or drinks\n14\nRetail space including a museum and gallery whose purpose is the sale of objects\n14\nSchool - general purpose learning areas and tutorial rooms\n4.5\nSole-occupancy unit of a Class 3 or 9c building\n5\nStorage\n1.5\nService area, cleaner's room and the like\n1.5\nToilet, locker room, staff room, rest room and the like\n3\nWholesale storage area with a vertical illuminance target of 160 lx\n4\nStairways, including fire-isolated stairways\n2\nLift cars\n5.5\nTable Notes\nIn areas not listed above, the maximum illumination power density is—\nfor an illuminance not more than 80 lx, 2 W/m2; and\nfor an illuminance more than 80 lx and not more than 160 lx, 2.5 W/m2; and\nfor an illuminance more than 160 lx and not more than 240 lx, 3 W/m2; and\nfor an illuminance more than 240 lx and not more than 320 lx, 4.5 W/m2; and\nfor an illuminance more than 320 lx and not more than 400 lx, 6 W/m2; and\nfor an illuminance more than 400 lx and not more than 600 lx, 10 W/m2; and\nfor an illuminance more than 600 lx and not more than 800 lx, 11.5 W/m2.\nFor enclosed spaces with a Room Aspect Ratio of less than 1.5, the maximum illumination power density may be increased by dividing it by an adjustment factor for room aspect which is 0.5 + (Room Aspect Ratio/3).\nThe Room Aspect Ratio of the enclosed space is determined by the formula: A/(H x C), where—\nA is the area of the enclosed space; and\nH is the height of the space measured from the floor to the highest part of the ceiling; and\nC is the perimeter of the enclosed space at floor level.\nIn addition to 2, the maximum illumination power density may be increased by dividing it by the illumination power density adjustment factor in Table J7D3b and Table J7D3c.\nCirculation spaces are included in the allowances listed in this table.\nTable J7D3b Illumination power density adjustment factor for a control device\nItem Notes 1 and 2\nDescription\nillumination power density adjustment factor\nDemand-operated controls\nIn a toilet or change room, other than a public toilet, in a Class 6 building\n0.4\nDemand-operated controls\nWhere a group of light fittings serving less than 100 m2 is controlled by one or more detectors\n0.6\nDemand-operated controls\nWhere a group of light fittings serving 100 m2 or more is controlled by one or more detectors\n0.7\nProgrammable dimming system Note 3\nWhere not less than 75% of the area of a space is controlled by programmable dimmers\n0.85\nFixed dimming Notes 3 and 4\nAll fittings with fixed dimming\nWhichever is greater of (a) 0.5; or (b) 0.2+0.8L where L = the illuminance turndown for the fixed dimming.\nLumen depreciation dimming Note 3\nAll fittings with lumen depreciation dimming\n0.85\nTwo stage sensor - equipped lights with minimum power of 30 % of peak power or less\nFire stairs and other spaces not used for regular transit\n0.4\nTwo stage sensor - equipped lights with minimum power of 30% of peak power or less\nTransitory spaces in regular use or in a carpark\n0.7\nDaylight sensor and dynamic lighting control device - dimmed or stepped switching of lights adjacent windows Notes 3 and 5\nIn a Class 5, 6, 7, 8 or 9b building or a Class 9a building, other than a ward area, where the lights are adjacent windows, other than roof lights, for a distance from the window equal to the depth of the floor to window head height\n0.5 Note 3\nDaylight sensor and dynamic lighting control device - dimmed or stepped switching of lights adjacent windows Notes 3 and 5\nServing a Class 3 or 9c building, or a Class 9a ward a","g":"/ncc/j7d3","a19":["J6.2"]},{"c":"J7D4","t":"Interior artificial lighting and power control","p":"Part J7 Artificial lighting and power","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j7-artificial-lighting-and-power#J7D4","x":"(1) In a Class 4 part of a building, all artificial lighting of a room or space must be individually operated in accordance with Specification 40 by–\na manual switch; or\nother control device; or\na combination of (a) and (b).\n(2) Subject to (3) to (13), other than in a Class 4 part of a building, all artificial lighting must be controlled by demand-operated control devices in accordance with Specification 40.\n(3) A room or space with regular occupancy may have a time switch installed that—\noverrides demand-operated controls during the period of regular occupancy; and\ncomplies with Specification 40.\n(4) A room or space with less than 20 W of artificial lighting that is situated within a larger room or space, may be controlled by manual switch when the artificial lighting within the larger room or space is activated.\n(5) A space within a carpark with regular occupancy for greater than 5000 hours per annum need not have demand-operated control.\n(6) For the purposes of (3), (4) and (5) “regular occupancy” is when a room or space is–\noccupied by more than 1 person per 40 m2; or\nused more than once every 15 minutes.\n(7) Demand-operated control must be provided in the sole-occupancy unit of a Class 3 building, other than where providing accommodation for people with a disability or the aged, to disable the artificial lighting, air-conditioning, local fans and bathroom heating when the sole-occupancy unit is unoccupied.\n(8) A demand-operated control required by (2) must, for other than a single functional space such as an auditorium, theatre, swimming pool, sporting stadium or warehouse, not operate more than 250 m2 of lighting.\n(9) In a Class 5, 6 or 8 building of more than 250 m2, artificial lighting in a natural lighting zone adjacent to windows must be separately controlled from artificial lighting not in a natural lighting zone in the same storey except where—\nthe room containing the natural lighting zone is less than 20 m2; or\nthe room’s natural lighting zone contains less than 4 luminaires; or\n70% or more of the luminaires in the room are in the natural lighting zone.\n(10) Artificial lighting in a fire-isolated stairway, fire-isolated passageway or fire-isolated ramp must be controlled by a demand-operated control in accordance with Specification 40.\n(11) Artificial lighting in a foyer, corridor and other circulation spaces—\nof more than 250 W within a single zone; and\nadjacent to windows,\nmust be controlled by a daylight sensor and dynamic lighting control device in accordance with Specification 40.\n(12) Artificial lighting for daytime travel in the first 19 m of travel in a carpark entry zone must be controlled by a daylight sensor in accordance with Specification 40.\n(13) The requirements of (1) to (12) do not apply to the following:\nEmergency lighting in accordance with Part E4, including dedicated light sources for photoluminescent exit signs required by S25C3(a).\nWhere artificial lighting is needed for 24 hour occupancy such as for a manufacturing process, parts of a hospital, an airport control tower or within a detention centre.","g":"/ncc/j7d4","a19":["J6.3"]},{"c":"J7D5","t":"Interior decorative and display lighting","p":"Part J7 Artificial lighting and power","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j7-artificial-lighting-and-power#J7D5","x":"(1) Interior decorative and display lighting, such as for a foyer mural or art display, must be controlled—\nseparately from other artificial lighting; and\nby a manual switch for each area other than when the operating times of the displays are the same in a number of areas such as in a museum, art gallery or the like, in which case they may be combined; and\nby a time switch in accordance with Specification 40 where the display lighting exceeds 1 kW.\n(2) Window display lighting must be controlled separately from other display lighting.","g":"/ncc/j7d5","a19":["J6.4"]},{"c":"J7D6","t":"Exterior artificial lighting","p":"Part J7 Artificial lighting and power","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j7-artificial-lighting-and-power#J7D6","x":"(1) Exterior artificial lighting attached to or directed at the facade of a building, must—\nbe controlled by—\na daylight sensor; or\na time switch that is capable of switching on and off electric power to the system at variable pre-programmed times and on variable pre-programmed days; and\nwhen the total lighting load exceeds 100 W—\nuse LED luminaires for 90% of the total lighting load; or\nbe controlled by a demand-operated control in accordance with Specification 40; or\nwhen used for decorative purposes, such as façade lighting or signage lighting, have a separate time switch in accordance with Specification 40.\n(2) The requirements of (1)(b) do not apply to the following:\nEmergency lighting in accordance with Part E4.\nLighting around a detention centre.","g":"/ncc/j7d6","a19":["J6.5"]},{"c":"J7D7","t":"Boiling water and chilled water storage units","p":"Part J7 Artificial lighting and power","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j7-artificial-lighting-and-power#J7D7","x":"Power supply to a boiling water or chilled water storage unit must be controlled by a time switch in accordance with Specification 40.","g":"/ncc/j7d7","a19":["J6.6"]},{"c":"Table J7D8a","t":"Lift idle and standby energy performance level","p":"Part J7 Artificial lighting and power","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j7-artificial-lighting-and-power#_e2e2d27e-835f-49d9-8757-9322048dfc04","x":"Rated load | Idle and standby energy performance level in accordance with ISO 25745-2 Note\n≤ 800 kg | 2\n> 800 kg to ≤ 2000 kg | 3\n> 2000 kg to ≤ 4000 kg | 4\n> 4000 kg | 5\nTable Notes\nApplies to the standby power used after 30 minutes.","tb":"J7D8","g":"/ncc/table-j7d8a"},{"c":"Table J7D8b","t":"Lift energy efficiency class","p":"Part J7 Artificial lighting and power","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j7-artificial-lighting-and-power#_bf3a4869-646a-48ff-a326-997ed502221f","x":"Usage category in accordance with ISO 25745-2 | Energy efficiency class in accordance with ISO 25745-2\n1-4 | C\n≥ 5 | D","tb":"J7D8","g":"/ncc/table-j7d8b"},{"c":"J7D8","t":"Lifts","p":"Part J7 Artificial lighting and power","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j7-artificial-lighting-and-power#J7D8","x":"Lifts must—\nbe configured to ensure artificial lighting and ventilation in the car are turned off when it is unused for 15 minutes; and\nachieve the idle and standby energy performance level in Table J7D8a; and\nachieve—\nthe energy efficiency class in Table J7D8b; or\nif a dedicated goods lift, energy efficiency class D in accordance with ISO 25745-2.\nTable J7D8a Lift idle and standby energy performance level\nRated load\nIdle and standby energy performance level in accordance with ISO 25745-2 Note\n≤ 800 kg\n2\n> 800 kg to ≤ 2000 kg\n3\n> 2000 kg to ≤ 4000 kg\n4\n> 4000 kg\n5\nTable Notes\nApplies to the standby power used after 30 minutes.\nTable J7D8b Lift energy efficiency class\nUsage category in accordance with ISO 25745-2\nEnergy efficiency class in accordance with ISO 25745-2\n1-4\nC\n≥ 5\nD","g":"/ncc/j7d8","a19":["J6.7"]},{"c":"J7D9","t":"Escalators and moving walkways","p":"Part J7 Artificial lighting and power","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j7-artificial-lighting-and-power#J7D9","x":"Escalators and moving walkways must have the ability to slow to between 0.2 m/s and 0.05 m/s when unused for more than 15 minutes.","g":"/ncc/j7d9","a19":["J6.8"]},{"c":"J8D1","t":"Deemed-to-Satisfy Provisions","p":"Part J8 Heated water supply and swimming pool and spa pool plant","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j8-heated-water-supply-and-swimming-pool-and-spa-pool-plant#J8D1","x":"(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements J1P1 to J1P4 are satisfied by complying with—\nJ2D2; and\nJ3D2 to J3D15; and\nJ4D2 to J4D7; and\nJ5D2 to J5D8; and\nJ6D2 to J6D13; and\nJ7D2 to J7D9; and\nJ8D2 to J8D5; and\nJ9D2 to J9D5.\n(2) Where a Performance Solution is proposed, the relevant Performance Requirements must be determined in accordance with A2G2(3) and A2G4(3) as applicable.","g":"/ncc/j8d1","a19":["J7.0"]},{"c":"J8D2","t":"Application of Part","p":"Part J8 Heated water supply and swimming pool and spa pool plant","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j8-heated-water-supply-and-swimming-pool-and-spa-pool-plant#J8D2","x":"The Deemed-to-Satisfy Provisions of this Part do not apply to a Class 4 part of a building.","g":"/ncc/j8d2","a19":["J7.2"]},{"c":"J8D3","t":"Heated water supply","p":"Part J8 Heated water supply and swimming pool and spa pool plant","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j8-heated-water-supply-and-swimming-pool-and-spa-pool-plant#J8D3","x":"(1) Pipework circulating heated water for food preparation and sanitary purposes must be insulated in accordance with J6D9, including 500 mm along each branch line.\n(2) Trace-heated pipework carrying heated water for food preparation and sanitary purposes must be insulated in accordance with J6D9.\n(3) A building with gas heated water for food preparation and sanitary purposes must be provided with—\nreserved electrical capacity sufficient to support future installation of air-source heat pump water heating equipment for food preparation and sanitary purposes assuming a nominal coefficient of performance of 3.25; and\nreserved space within the main electrical distribution board comprising at least one empty three-phase circuit breaker slot and 4 DIN rail spaces per 35 kW of water heating capacity labelled to indicate reservation for future installation of heated water supply; and\nreserved space in the electrical riser or supply pathway for future water heating equipment, sized in accordance (a); and\nreserved plant area with—\nspace to accommodate heating plant of 7 m² plus 0.04 m²/kW of heating capacity; and\nsufficient ventilation to achieve airflow of 115 L/s per kW of heating, with no recirculation of air.\n(4) The capacity and space required by (3) must be sufficient to serve the same design load used to specify any gas-powered water heating equipment for food preparation and sanitary purposes.","g":"/ncc/j8d3","a19":["J7.3"]},{"c":"J8D4","t":"Swimming pool heating and pumping","p":"Part J8 Heated water supply and swimming pool and spa pool plant","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j8-heated-water-supply-and-swimming-pool-and-spa-pool-plant#J8D4","x":"(1) Heating for a swimming pool must be by—\na solar heater; or\na heater using reclaimed heat from another process such as reject heat from a refrigeration plant; or\na geothermal heater; or\na gas heater that achieves a minimum gross thermal efficiency of 90%; or\na heat pump; or\na combination of (a) to (e).\n(2) Where some or all of the heating required by (1) is by a gas heater or a heat pump, the swimming pool must have—\na cover with a minimum R-Value of 0.05; and\na time switch to control the operation of the heater.\n(3) A time switch must be provided to control the operation of a circulation pump for a swimming pool.\n(4) Where required, a time switch must be capable of switching electric power on and off at variable pre-programmed times and on variable pre-programmed days.\n(5) Pipework carrying heated or chilled water for a swimming pool must comply with the insulation requirements of J6D9.\n(6) A building with gas heated water for a swimming pool must be provided with—\nreserved electrical capacity sufficient to support future installation of air-source heat pump water heating equipment for the swimming pool assuming a nominal coefficient of performance of 3.25; and\nreserved space within the main electrical distribution board comprising at least one empty three-phase circuit breaker slot and 4 DIN rail spaces per 35 kW of water heating capacity, labelled to indicate reservation for future installation of water heating equipment for the swimming pool; and\nreserved space in the electrical riser or supply pathway for future swimming pool heating equipment sized in accordance with (a); and\nreserved plant area with—\nspace to accommodate heating plant of 7 m² plus 0.04 m²/kW of heating capacity; and\nsufficient ventilation openings to achieve airflow of 115 L/s per kW of heating capacity with no recirculation of air; and\na hot water circulation system that operates at a peak temperature of less than 50°C.\n(7) The capacity and space required by (6) must be sufficient to serve the same design load used to specify any gas-powered swimming pool water heating equipment.\n(8) For the purpose of J8D4, a swimming pool does not include a spa pool.","g":"/ncc/j8d4","a19":["J7.4"]},{"c":"J8D5","t":"Spa pool heating and pumping","p":"Part J8 Heated water supply and swimming pool and spa pool plant","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j8-heated-water-supply-and-swimming-pool-and-spa-pool-plant#J8D5","x":"(1) Heating for a spa pool that shares a water recirculation system with a swimming pool must be by—\na solar heater; or\na heater using reclaimed heat from another process such as reject heat from a refrigeration plant; or\na geothermal heater; or\na gas heater that achieves a minimum gross thermal efficiency of 90%; or\na heat pump; or\na combination of (a) to (e).\n(2) Where some or all of the heating required by (1) is by a gas heater or a heat pump, the spa pool must have—\na cover with a minimum R-Value of 0.05; and\na push button and a time switch to control the operation of the heater.\n(3) A time switch must be provided to control the operation of a circulation pump for a spa pool having a capacity of 680 L or more.\n(4) Where required, a time switch must be capable of switching electric power on and off at variable pre-programmed times and on variable pre-programmed days.\n(5) Pipework carrying heated or chilled water for a spa pool must comply with the insulation requirements of J6D9.\n(6) A building with gas heated water for spa pool heating must be provided with—\nreserved electrical capacity sufficient to support future installation of air-source heat pump water heating equipment for the spa pool assuming a nominal coefficient of performance of 3.25; and\nreserved space within the main electrical distribution board comprising at least one empty three-phase circuit breaker slot and 4 DIN rail spaces per 35 kW of water heating capacity, labelled to indicate reservation for future installation of water heating equipment for the spa pool; and\nreserved space in the electrical riser or supply pathway for future the spa pool heating equipment sized in accordance with (a); and\nreserved plant area with—\nspace to accommodate heating plant of 7 m² plus 0.04 m²/kW of heating capacity; and\nsufficient ventilation openings to achieve airflow of 115 L/s per kW of heating capacity, with no recirculation of air; and\na hot water circulation system and associated coils and heat exchangers serving the spa pool, designed to operate a peak temperature of less than 50°C.\n(7) The capacity and space required by (6) must be sufficient to serve the same design load used to specify any gas-powered spa pool water heating equipment.","g":"/ncc/j8d5"},{"c":"J9D1","t":"Deemed-to-Satisfy Provisions","p":"Part J9 Energy monitoring and on-site distributed energy resources","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j9-energy-monitoring-and-site-distributed-energy-resources#J9D1","x":"(1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements J1P1 to J1P4 are satisfied by complying with—\nJ2D2; and\nJ3D2 to J3D15; and\nJ4D2 to J4D7; and\nJ5D2 to J5D8; and\nJ6D2 to J6D13; and\nJ7D2 to J7D9; and\nJ8D2 to J8D5; and\nJ9D2 to J9D5.\n(2) Where a Performance Solution is proposed, the relevant Performance Requirements must be determined in accordance with A2G2(3) and A2G4(3) as applicable.","g":"/ncc/j9d1","a19":["J8.0"]},{"c":"J9D2","t":"Application of Part","p":"Part J9 Energy monitoring and on-site distributed energy resources","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j9-energy-monitoring-and-site-distributed-energy-resources#J9D2","x":"The Deemed-to-Satisfy Provisions of this Part do not apply—\nwithin a Class 4 part of a building; or\nto a Class 8 electricity network substation.","g":"/ncc/j9d2","a19":["J8.1"]},{"c":"J9D3","t":"Facilities for energy monitoring","p":"Part J9 Energy monitoring and on-site distributed energy resources","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j9-energy-monitoring-and-site-distributed-energy-resources#J9D3","x":"(1) A building or sole-occupancy unit with a floor area of more than 500 m2 must have energy meters configured to record the time-of-use consumption of gas and electricity.\n(2) A building with a floor area of more than 2 500 m2 must have energy meters configured to enable individual time-of-use energy data recording, in accordance with (3), of—\nair-conditioning plant including, where appropriate, heating plant, cooling plant and air handling fans; and\nartificial lighting; and\nappliance power; and\ncentral hot water supply; and\ninternal transport devices including lifts, escalators and moving walkways where there is more than one serving the building; and\non-site renewable energy equipment; and\non-site electric vehicle charging equipment; and\non-site battery systems; and\nother ancillary plant.\n(3) Energy meters required by (2) must be interlinked by a communication system that collates the time-of-use energy data to a single interface monitoring system where it can be stored, analysed and reviewed.\n(4) The provisions of (2) do not apply to energy meters serving individual sole-occupancy units with a floor area of less than 2 500 m2.\n(5) Where a building has an Environmental Management Information System facility it must record, in addition to J9D3(2)(a) to (i), on a 5 minute time interval basis—\nthe energy use of any piece of equipment predicted to consume more than 5% of total building annual energy use; and\nentering and leaving temperatures and energy use for each chiller, heat pump, electric heater or hot water heater used in air-conditioning; and\nthe temperature of all internal air-conditioning zones; and\nthe water flow and return temperature of chilled and heated water loops; and\nthe external temperature and humidity local to the building; and\nmeasurement of internal carbon dioxide and car park pollutant levels, where these are used for controlling fan speed or outside air quantities; and\ntotal instantaneous building electricity demand, recorded as an average over every 5 minutes of building operation; and\nthe start/stop command value and speed of air-conditioning and mechanical ventilation fans and pumps and associated system pressure measurement and set point; and\nthe damper command for economy cycle and ventilation dampers; and\nthe damper or valve command for energy reclaim equipment.\n(6) The Environmental Management Information System in (5) must—\nallow demand management control of the building’s—\nrenewable energy system, including any battery energy storage system installed; and\nlighting system; and\nair-conditioning and ventilation system; and\nelectric vehicle charging equipment; and\ninclude an operational interface that enables remote users to visualise system data and operational status; and\nallow for the visualisation of data in a graphical format, including the ability to compare individual data streams integrated over time periods and in time series; and\nbe able to provide bulk downloads of at least 2 years of historic time series data to users; and\nallow scheduling, supervisory level setpoint override and modulation set-back of the air-conditioning and ventilation system; and\nincorporate monitoring and verification functionality with the capability to—\nprovide monitoring and verification of a change in energy use in accordance with the International Performance Measurement and Verification Protocol Options B and C; and\nautomatically determine an energy performance baseline from historical building data and weather data; and\ncompare building performance against the baseline, both numerically and graphically; and\nprovide forecasts of the building’s renewable energy production.\n(7) The requirements of (5) and (6) do not apply to services that consume less than 5% of the building’s total annual energy consumption.\nNotes\nAn Environmental Management Information System that complies with J9D3(5) and (6) and records data as required by J9D3(2)(a) to (i) satisfies the requirement for ‘energy meters’ in J9D3(2).","g":"/ncc/j9d3","a19":["J8.3"]},{"c":"Table J9D4","t":"Electric vehicle distribution board requirement for each storey of a carpark","p":"Part J9 Energy monitoring and on-site distributed energy resources","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j9-energy-monitoring-and-site-distributed-energy-resources#_905b9d5c-3379-4cf4-a788-7e97e00b1602","x":"Carpark spaces per storey for electric vehicles | Electrical distribution boards required for electric vehicle charging per storey\n0 - 9 | 0\n10 - 24 | 1\n25 - 48 | 2\n49 - 72 | 3\n73 - 96 | 4\n97 - 120 | 5\n121 - 144 | 6\n145 - 168 | 7\nTable Notes\nWhere there are more than 168 carpark spaces per storey, one additional distribution board must be provided for each additional 24 spaces or part thereof.\nThe number of distribution boards required is determined by application of J9D4(2)(d).","tb":"J9D4","g":"/ncc/table-j9d4"},{"c":"J9D4","t":"Facilities for electric vehicle charging equipment","p":"Part J9 Energy monitoring and on-site distributed energy resources","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j9-energy-monitoring-and-site-distributed-energy-resources#J9D4","x":"(1) Subject to (2), a carpark associated with a Class 3, 5, 6, 7b, 8 or 9 building must be provided with electrical distribution boards dedicated to electric vehicle charging—\nin accordance with Table J9D4 in each storey of the carpark; and\nlabelled to indicate use for electric vehicle charging equipment.\n(2) Electrical distribution boards dedicated to serving electric vehicle charging in a carpark must—\nbe fitted with a charging control system with the ability to manage and schedule charging of electric vehicles in response to total building demand; and\nwhen associated with a Class 5 to 9 building, have capacity for each circuit to support an electric vehicle charger able to deliver a minimum of 12 kWh from 9:00 am to 5:00 pm daily; and\nwhen associated with a Class 3 building, have capacity for each circuit to support an electric vehicle charger able to deliver a minimum of 48 kWh from 11:00 pm to 7:00 am daily; and\nbe sized to support the future installation of a 7 kW (32 A) type 2 electric vehicle charger in—\n10% of car parking spaces associated with a Class 5 or 6 building; or\n20% of car parking spaces associated with a Class 3, 7b, 8 or 9 building; and\ncontain space of at least 36 mm width of DIN rail per outgoing circuit for individual sub-circuit for individual sub-circuit electricity metering to record electricity use of electric vehicle charging equipment; and\nbe labelled to indicate the use of the space required by (f) is for the future installation of metering equipment.\nLimitations\nJ9D4 does not apply to a stand alone Class 7a building.\nTable J9D4 Electric vehicle distribution board requirement for each storey of a carpark\nCarpark spaces per storey for electric vehicles\nElectrical distribution boards required for electric vehicle charging per storey\n0 - 9\n0\n10 - 24\n1\n25 - 48\n2\n49 - 72\n3\n73 - 96\n4\n97 - 120\n5\n121 - 144\n6\n145 - 168\n7\nTable Notes\nWhere there are more than 168 carpark spaces per storey, one additional distribution board must be provided for each additional 24 spaces or part thereof.\nThe number of distribution boards required is determined by application of J9D4(2)(d).","g":"/ncc/j9d4"},{"c":"Table J9D5a","t":"Minimum solar photovoltaic system installed peak output (W) per m2 of conditioned space for buildings without gas","p":"Part J9 Energy monitoring and on-site distributed energy resources","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j9-energy-monitoring-and-site-distributed-energy-resources#_0c9557ae-6682-4776-9e36-05095905407a","x":"Building Class | Climate zone 1 | Climate zones 2 to 7 | Climate zone 8\nClass 5, 6, and 7 | 95 | 65 | 55\nClass 3 and 9 | 70 | 40 | 35","tb":"J9D5","g":"/ncc/table-j9d5a"},{"c":"Table J9D5b","t":"Minimum solar photovoltaic system installed peak output (W) per m2 of conditioned space for buildings with gas, in addition to the requirements of J9D5(2)","p":"Part J9 Energy monitoring and on-site distributed energy resources","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j9-energy-monitoring-and-site-distributed-energy-resources#_70595c32-f1dc-48f5-a273-c6e3d88e368d","x":"Building Class | Climate zones 1 and 3 | Climate zones 2 and 5 | Climate zones 4 and 6 | Climate zone 7 | Climate zone 8\nClass 5, 6 and 7 | 0 | 0 | 1 | 1.7 | 4.7\nClass 3 and 9 | 2.6 | 0.9 | 2.6 | 0.9 | 0","tb":"J9D5","g":"/ncc/table-j9d5b"},{"c":"J9D5","t":"Facilities for solar photovoltaic and battery systems","p":"Part J9 Energy monitoring and on-site distributed energy resources","u":"/editions/ncc-2025/adopted/volume-one/j-energy-efficiency/part-j9-energy-monitoring-and-site-distributed-energy-resources#J9D5","x":"(1) The main electrical switchboard of a building must contain at least 2 empty three-phrase circuit breaker slots and 4 DIN rail spaces labelled to indicate the use of each space for a battery system.\n(2) A building must be provided with an on-site solar photovoltaic system—\nthat covers 100% of the roof area, excluding areas—\nshaded for more than 25% of annual daylight hours; or\nwhere the roof pitch exceeds 45° relative to horizontal; or\nthat are awnings; or\nthat are car parks; or\nthat are roof gardens; or\nthat are terraces or other rooftop areas designated for occupation; or\nused for roof lights or translucent roofing for natural lighting or the like; or\ndesignated as a trafficable area, access for height safety systems or plant maintenance access or a required path of travel to an exit; or\nused for plant equipment, services installations or the like; or\nabove exhaust air flows from heat rejection equipment or the like; or\nwhere provision of solar photovoltaic panel is impractical on account of panel size or mounting system limitations; or\nwith a peak system output rating per m2 of building conditioned space not less than those specified in Table J9D5a.\n(3) In addition to (2), a building where gas is used for building services must be provided with further on-site photovoltaic system peak output capacity not less than the value specified in Table J9D5b.\n(4) If the on-site solar photovoltaic system in (3) is placed on a building roof, the panels must—\nnot be shaded for more than 25% of daylight hours; and\nnot have a pitch of more than 45°.\nLimitations\nThe requirements of J9D5(2) do not apply to a building—\nwhere 100% of the effective roof area is shaded for more than 70% of annual daylight hours; or\nprovided with an on-site renewable energy generation system with a generation capacity at least equivalent to a solar photovoltaic system described under J9D5(2).\nThe requirements of J9D5(1) do not apply to a building with battery systems installed.\nTable J9D5a Minimum solar photovoltaic system installed peak output (W) per m2 of conditioned space for buildings without gas\nBuilding Class\nClimate zone 1\nClimate zones 2 to 7\nClimate zone 8\nClass 5, 6, and 7\n95\n65\n55\nClass 3 and 9\n70\n40\n35\nTable J9D5b Minimum solar photovoltaic system installed peak output (W) per m2 of conditioned space for buildings with gas, in addition to the requirements of J9D5(2)\nBuilding Class\nClimate zones 1 and 3\nClimate zones 2 and 5\nClimate zones 4 and 6\nClimate zone 7\nClimate zone 8\nClass 5, 6 and 7\n0\n0\n1\n1.7\n4.7\nClass 3 and 9\n2.6\n0.9\n2.6\n0.9\n0","g":"/ncc/j9d5"}]}