NCC Volume One · 2025 · 2022 · 2019

Find the NCC issues before your building surveyor does.

Upload a floor plan. CodeLens Studio pins egress, fire, access, amenity and energy issues on the sheet. Each one shows the clause, what was measured, the limit and a suggested fix, in about two minutes per sheet. When Rev E comes in, it tells you what's fixed, what's new and what's still open.

Sheet sets from Revit, Archicad and AutoCAD Every pass or fail traced to a clause Reports under your own logo
A-201 · Level 2 General Arrangement · Rev DExample sheet
ABCD 123 BOARDOPEN WORKPLACEMEETINGAMENITIESKITCHENCORE 38 m²412 m²46 m²52 m²FS-1FS-2 40.7 m 1 2 3 4 5
Whole sheet setsUpload the PDF and pick the floor plans. PNG, JPG, TIFF and HEIC work too.
Every revision trackedRev E is compared with Rev D. Statuses and owners carry across.
Your report, your logoAn A4 PDF with pinned drawing, findings and a sign-off block.
Editions and statesNCC 2025, 2022 or 2019, with NSW and Victorian variations applied.
01 — Why

A compliance comment at permit stage costs more than the fix.

The fix itself is usually small: a door re-hung, a partition moved, a cubicle widened. The cost is everything that comes after: drawings re-issued, consultants re-engaged, the program pushed back, and a call to the client explaining why.

D3D25

The door that swings the wrong way

Found on the drawing, it's a change to the door family. Found on site, it's a new frame, new hardware and another inspection.

Swing in the direction of egress
D2D5

The 40.7 metre route

Travel distance creeps as fit-outs change. One more meeting room and a floor that passed last month doesn't pass any more.

≤ 20 m to a point of choice · ≤ 40 m to one of 2 exits
F4D5

The missing ambulant cubicle

On a tight amenities plan it's easy to miss. Once the joinery and partitions are ordered, it's expensive to fix.

1 male + 1 female ambulant compartment, AS 1428.1
Reputation
Surveyors notice which practices' drawings arrive clean. So do clients, when their permit isn't held up by a door swing.
02 — Time

Your numbers, not ours.

Set the sliders to match how your practice checks drawings today. The calculation is shown in full below, so you can check it.

Every issue of every plan sheet, including re-issues after design changes.
Measuring travel routes, counting occupants, checking doors, widths and amenities against the code.
Rate of the person who does the check.
Hours back each month
11.7hours
A$2,100fee time per month
A$25,200per year

At these numbers, the A$249 Practice plan pays for itself after 3 sheets a month.

How it's calculated: sheets × (your manual minutes − 10 minutes to review the pins and confirm the drawing facts) ÷ 60. The drawing read itself runs in the background while you work. This counts first-pass checking time only. It doesn't count the cost of an issue found late, which is usually the larger number.

03 — How it works

Reading the drawing and judging it are kept apart.

Reading a plan means finding room names, door swings and where the stairs are. Deciding whether 40.7 m meets the limit is a separate job. In CodeLens every limit comes from fixed rules written from the NCC text, so the same drawing always gets the same answer, and you can see exactly why.

Step 1

Upload the set

Drop in a PDF sheet set exported from Revit, Archicad or AutoCAD. Floor plans are pre-selected, and you choose which sheets to check.

Step 2

Read the drawing

Rooms and uses, doors and door numbers, exits, travel routes, toilets, stairs, balustrades, fire services and the scale. Door, hardware and area schedules in the set are read too. Anything can be corrected, and corrections re-run the checks for free.

Step 3

Check against the code

Occupant numbers from Table D2D18, then travel distance, exits, door widths and hardware, construction type and compartment size, hydrants, sprinklers, emergency lighting, stairs, toilets, ramps, parking, Section J glazing, EV and solar.

Step 4

Resolve as a team

Each issue is pinned where it occurs. Assign it, comment on it, mark it as a Performance Solution. Upload the next revision and anything fixed closes on its own.

04 — Revisions, reports and RFIs

Rev E shows what Rev D fixed. The report carries your name.

Drawings change every week. Upload the next revision and CodeLens matches it to the last one by drawing number, closes what's been fixed, flags what's new, and keeps every Performance Solution and owner attached to the issues still open.

A-201 · Rev E compared with Rev D

One screen answers the question every design review starts with.

2 new3 fixed4 still open
NEWD2D5Travel distance 41.2 m from new meeting roomMeeting room added on the east side
FIXEDD3D25FS-2 door now swings with egressClosed automatically on Rev E
FIXEDF4D4Basin numbers now meet Table F4D4aClosed automatically on Rev E
OPEND4D4Entry ramp 1:12, needs 1:14Performance Solution · J. Chen · carried from Rev D
  • Statuses carry across. In progress, Performance Solution and the assignee follow the issue to the next revision.
  • Compare any two. Rev E against Rev B, if that's the set the surveyor last saw.

A report you'd put your name to

Add your practice logo and footer once. Every report is an A4 PDF with the pinned drawing, each finding with its clause, the changes since the last revision, and a sign-off block.

Surveyor comments in. Response letter out.

Paste the RFI. Each comment is matched to the finding it refers to, by clause (2019 numbers too) and wording, then tracked to closure. The response letter writes itself from where each issue stands.

1Travel distance from the NE workstations appears to exceed 40 m.→ D2D5 · A-201 Rev E · fixed"Addressed. Route now 36.8 m as drawn on A-201 Rev E."
2Door to FS-2 swings against egress (BCA D2.20).→ D3D25 · 2019 number recognised"Addressed. Door re-hung to swing with egress."
3Entry ramp gradient does not comply.→ D4D4 · Performance Solution"To be addressed by a Performance Solution; report to follow."

It reads the whole sheet set, not just the plan

Plans rarely dimension doors or name hardware. That's on the door and hardware schedules. Upload them with the plans and every door is matched by number, on every floor.

  • Example from a clinic fit-out. A 7-door schedule turned five unknown doors into results, and found an office lock with a separate deadbolt on a door on the way to an exit. That fails D3D26, and the plan alone couldn't show it.
  • Disagreements flagged. If the plan says 820 mm and the schedule says 870 mm, you hear about it before the surveyor does.
  • Floor areas too. GFA from the area schedule feeds the fire compartment check.
Marked-up PDFThe original sheet with a numbered pin on every open item, and a schedule of pins. Attach it to the submission.
Read-only share linkSend the surveyor, client or services consultant a link to the drawing and its findings. No account needed. Expires when you choose.
Notified, not chasingTeam members get an email when an issue is assigned to them or a drawing they uploaded has been read.
05 — What it checks

34 clauses across fire, egress, services, access and energy.

The checks cover Volume One work in Class 2 common areas and Class 3, 5, 6, 7, 8 and 9 buildings. Items that depend on the building as a whole, like hydrants and sprinklers, are listed as systems to coordinate, so they reach the services consultants early. Each finding links to the official clause on NCC Online, and NSW and Victorian variations are applied when the project is in those states.

ClauseCheckWhat CodeLens does
D2D182019: D1.13Number of personsCounts occupants from room areas and 33 Table D2D18 uses, or seat counts where higher. Uses the table doesn't list are counted from seats or flagged for a rate agreed with the surveyor.
D2D52019: D1.4Exit travel distanceMeasures the walking route on the calibrated plan against the 20 m, 30 m and 40 m limits.
D2D32019: D1.2Number of exitsFlags single-exit storeys where effective height is over 25 m, plus the NSW rule for Class 9 storeys over 50 people.
D2D8 · D2D92019: D1.6Exit, path and door widthsChecks the 1 m path width, aggregate exit width for the population, and the 750 mm doorway minimum.
D3D252019: D2.20Swinging doorsFinds required-exit doors swinging against egress, and allows for the 200 m² and sanitary-compartment exemptions.
D3D262019: D2.21Operation of latchFlags keyed locks and lever-plus-deadbolt hardware on exit doors.
F4D5 · D4D72019: F2.4 · D3.6Accessible amenities and signageChecks ambulant cubicles at each toilet bank, and Braille/tactile and ambulant door signage.
C2D2 · C3D32019: C1.1 · C2.2Construction type and compartment sizeWorks out Type A, B or C from rise in storeys and class, then checks floor area against the compartment limit. Sprinklered buildings over the limit are routed to the large-isolated-building provisions.
C3D92019: C2.8Separation of classificationsFinds different classes side by side on a storey without a fire wall.
F4D42019: F2.3Toilet and basin numbersCounts pans, urinals and basins against the population, splitting male and female and counting accessible unisex facilities for both.
D4D4 · D4D122019: D3.3 · D3.11RampsChecks ramp, step ramp and kerb ramp gradients, and flags ramps rising more than 3.6 m.
D4D62019: D3.5Accessible parkingWorks out the accessible spaces needed for the number of car spaces and the building class.
D4D92019: D3.8Tactile indicatorsFlags stairs and ramps that aren't fire-isolated and have no tactile ground surface indicators shown.
E1D2–E1D142019: E1.3–E1.6Fire hydrants, hose reels, sprinklers, extinguishersWorks out which systems the building triggers from floor area, class, height and storeys, and checks they're shown. A sprinkler trigger on an unsprinklered building fails.
E4D2 · E4D5 · E4D92019: E4.2 · E4.5 · E4.9Emergency lighting, exit signs, EWISFlags storeys over 300 m², fire-isolated and non-fire-isolated stairs, and every exit door that needs a sign, plus buildings that need an emergency warning system.
D3D14 · D3D18 · D3D222019: D2.13 · D2.16 · D2.17Stairs, balustrades and handrailsChecks riser, going and 2R + G for public and private stairs, 865 mm and 1 m barrier heights, and 865 mm handrails where they're noted.
D2D5(1)2019: D1.4(a)Class 2 and 3 travel6 m from an apartment door to an exit or point of choice, 20 m to a single exit at road level, 20 m from common areas.
J4D4–J4D72019: J1.3–J1.6Section J building fabricRoof and floor R-values, roof lights, and the wall-glazing U-value and solar admittance of every facade, calculated with Specification 37. Glazing areas, U-values and SHGC fill in from the window schedule; shading multipliers are looked up from eave, fin and screen dimensions (S37C7).
J9D4 · J9D5New in 2022EV charging and solar PVSizes EV distribution boards and circuits per carpark storey, and solar PV from conditioned area and climate zone.
NCC 2025Current edition. Solar PV installed to Table J9D5a.
NCC 2022For projects under transition. 20% of the roof kept clear for PV.
NCC 2019 Amdt 1Older clause numbers. No EV or solar provisions.
Section J glazing, before the energy consultant asks Enter each facade, or fill it from the window schedule, and see the wall-glazing U-value and solar admittance against NCC 2025 or 2022 limits as you change the glazing. Over-glazed facades show up at sketch design, not after the Section J report comes back. The page shows which method passes (single facade or whole building), and what to change if neither does. Type in an eave depth or fin size and the shading calculator looks up the S37C7 multiplier, so you can see how much shade a facade needs before you add it to the drawings.
06 — Trust

Built to be checked, not taken on faith.

Your name is on the drawings, so you need to see why each issue was raised. Here's how.

Every finding shows its source

Measured on your calibrated plan, read from the drawing, or taken from project facts. You can see which, and how much weight to give it.

Correct anything, and tell us

If a room use, door or toilet was read wrong, change it, or click on the drawing to add a door that was missed. The checks re-run straight away, at no cost. Report it with a screenshot and we fix the reading for everyone. Reports that lead to a fix earn free sheet reads.

Linked to the source text

Every clause opens the official wording on ABCB's NCC Online. NSW and Victorian variations change the result when they apply, and are labelled when they do.

Private to your practice

People sign in with your practice email domain, and only they can see your projects. No passwords to manage: each sign-in uses a one-time code sent to your email.

Stored in the region

Drawings are stored in the Oceania region and used only to check your project. See our privacy policy.

A design aid, not a certificate

CodeLens helps you send cleaner drawings. Your building surveyor still determines compliance, and CodeLens says so on every report.

07 — Free tools

Free NCC tools. No sign-up.

Search the whole NCC in plain words, and use the same tables CodeLens Studio uses as quick calculators on any project today.

NCC search · NCC 2025 and 2022 · Volumes One, Two, Three · Housing ProvisionsSearch the whole NCC in plain wordsType “ramp slope”, “stair riser” or “fire door” and get the clause, its wording, every state variation and what changed since NCC 2022. Every clause, state variation and definition, with a page for each.Search the NCC →
D2D18 · D2D3 · D2D8 · D2D5

Occupants, exits and exit widths

Persons per storey from Table D2D18, how many exits, total exit width and travel distance limits.

Open calculator →
F4D4 · F4D5

Toilets for employees

Closet pans, urinals and washbasins from Tables F4D4a and F4D4b, with the ambulant toilet rule.

Open calculator →
J4D6 · Spec 37 · S37C7

Section J glazing and shading

Wall-glazing U-value and solar admittance for a facade, with eave, fin and screen shading multipliers.

Open calculator →
D3D14 · 11.2.2

Stairs

Every riser count that works for a floor-to-floor height, the going range, flights and landings. Commercial and houses.

Open calculator →
D3D11 · AS 1428.1

Ramps

Gradient from rise and run, checked as exit ramp, accessible ramp, walkway, step ramp and kerb ramp.

Open calculator →
C2D2 · C3D3 · D4D6

Construction type, compartments and parking

Type A, B or C construction, maximum fire compartment size, and accessible car spaces.

Open calculator →
RFIs · NCC 2019 → 2025

RFI resolver

Paste the surveyor's comments: get the clause behind each one (old 2019 numbers translated), your state's variation and a reply to edit.

Resolve an RFI →
A6 · C2D2 · C2D3 · C3D3

What class is my building?

Classification of each part, the 10% exemption, rise in storeys, effective height, type of construction and compartment limits.

Work it out →
A2G2 · Part A5

Performance Solution starter

Can't meet a Deemed-to-Satisfy clause? Get the Performance Requirements, Verification Methods, evidence options and a report outline.

Start one →
Lists · notes · CSV

Saved clause lists

Save clauses, tables and variations into a list per project, add notes, and export them for reports and RFI replies.

Open my lists →
ACT · NSW · NT · QLD · SA · TAS · VIC · WA

State variations side by side

Which states vary which clauses, and how, in one table for every NCC volume.

Open the matrix →
Pricing

Try it free on a live project. Pay when it earns its keep.

Every plan covers your whole team, every check, all three NCC editions and state variations, schedule reading, revision comparison, surveyor comment tracking, share links and reports under your logo. Correcting what was read and re-running the checks never uses a read. Unused pack reads are refundable within 14 days, and monthly plans cancel any time: see the terms of sale.

Free trial

See it on your drawings

A$0

One trial per practice. No card.

  • 10 sheet reads
  • 14 days
  • Whole team
  • A finished sample project to explore first
Start a free trial
Project pack

For one project

A$399

About A$13 a sheet. No subscription.

  • 30 sheet reads
  • Use within 90 days
  • Top up 10 reads for A$149
Buy a project pack
Practice · most popular

For a busy practice

A$249/ month

About A$6 a sheet. Or A$2,490 a year, two months free.

  • 40 sheet reads a month
  • Unused reads roll over one month
  • Cancel any time
Choose Practice
Studio

For multi-team offices

A$549/ month

About A$4.60 a sheet.

  • 120 sheet reads a month
  • Unused reads roll over one month
  • Priority support and onboarding
Choose Studio
Larger practice or several offices? Talk to us about volume pricing. Pay by card in the app. Invoice with every payment. No GST is charged: we're not registered for GST. Cancel a monthly plan any time. Already have a code? Sign in
08 — FAQ

Questions architects ask us.

Anything else: hello@codelensstudio.com.

What is CodeLens Studio?

CodeLens Studio is an NCC compliance checker for Australian architects and building designers. You upload floor plans and schedules, it reads them, checks them against 34 clauses of NCC Volume One, and pins each issue on the drawing with the clause, what it measured, the limit and how to fix it.

Which NCC editions and clauses does it check?

NCC 2025, NCC 2022 and NCC 2019 Amendment 1, Volume One (Class 2 to 9 buildings), with NSW and Victorian variations where they change the result. Checks cover egress (occupant numbers, exits, travel distances, exit widths, doors), fire (construction type, compartment size, hydrants, hose reels, sprinklers), services (emergency lighting, exit signs, warning systems), access (ramps, stairs, accessible parking), amenity (toilets, ambulant and accessible facilities) and energy (Section J glazing and fabric, EV charging and solar provisions).

Does it replace my building surveyor or certifier?

No. CodeLens Studio is a design-stage aid that helps you find likely issues before you submit. The relevant building surveyor or certifier decides compliance, and every report says so. Each finding shows its source and links to the official NCC text, so you can check why it was raised.

What drawings can I upload?

PDF (single or multi-sheet), PNG, JPG, WebP, TIFF, HEIC, GIF, BMP and SVG, up to 30 MB. Export from Revit, Archicad or AutoCAD to PDF. Floor plans are checked, and door, hardware, window and area schedules fill in the details. PDFs that keep text as text read most accurately.

How long does a check take?

Usually a few minutes per sheet. Large sheets with small text are read in zoomed sections, which takes a little longer and is more accurate.

What if it reads something wrong?

You can correct any room, door, toilet or measurement, or add a door that was missed by clicking on the drawing. The checks re-run straight away and corrections never use a read. Report the mistake with a screenshot and we fix the reading for everyone; reports that lead to a fix earn free sheet reads.

Who can see my drawings?

Only people who sign in with your practice's email domain. Drawings are stored in the Oceania region, used only to check your project, and never used to train anyone's systems. Delete a project and its drawings go within 30 days. See the privacy policy for details.

How much does it cost? Is there a free trial?

The free trial gives your practice 10 sheet reads for 14 days, plus a finished sample project to explore, with no credit card. After that: a Project pack is A$399 for 30 reads over 90 days, Practice is A$249 a month for 40 reads, and Studio is A$549 a month for 120 reads. Top-ups are A$149 for 10 reads. No GST is charged.

What counts as a sheet read?

One read each time a drawing or schedule sheet is read. Re-checking after you change project details or correct what was read, measuring, comments, reports, marked-up PDFs and share links are all free. Failed reads are put back automatically.

Can I cancel or get a refund?

Monthly plans can be cancelled at any time and run to the end of the paid month. Unused reads from a Project pack or top-up can be refunded within 14 days of purchase. See the terms of sale.

Does it help with revisions and surveyor RFIs?

Yes. Upload a new revision and it shows what's fixed, what's new and what's still open, carrying across your team's assignments. Paste the surveyor's comments and it matches them to findings, tracks each one to closure and drafts your response letter, clause by clause.

Can I search the NCC for free?

Yes. NCC search searches every clause, state and territory variation and definition of the National Construction Code (NCC 2025 and 2022, Volumes One, Two and Three and the Housing Provisions) in plain words, such as “ramp slope”, “stair riser” or “fire door”, or by clause number. Each result shows the NCC wording and links to the official clause on NCC Online.

Are there free NCC calculators?

Yes. The free tools page has calculators for occupant numbers (Table D2D18), number of exits (D2D3), exit widths (D2D8), travel distances (D2D5), employee toilets (F4D4), and Section J glazing U-value, solar admittance and shading multipliers (Specification 37). They run in your browser with no sign-up.