10.7.6 Acceptable forms of construction for concrete walls
Part 10.7 Sound insulation · NCC 2019: Table 3.8.6.1b
(1) Acceptable forms of construction for concrete walls are set out in (2) to (5).
(2) 150 mm thick plain off form concrete, has an Rw + Ctr of not less than 50, if constructed in accordance with Figure 10.7.6a.
(3) 200 mm thick concrete panel with one layer of 13 mm plasterboard or 13 mm cement render on each face, has an Rw + Ctr of not less than 50, if constructed in accordance with Figure 10.7.6b.
(4) A 100 mm thick concrete panel with—
a row of 64 mm steel studs at 600 mm centres, spaced 25 mm from the concrete panel; and
80 mm thick polyester insulation or 50 mm thick glass wool insulation with a density of 11 kg/m3, positioned between studs; and
two layers of 13 mm plasterboard fixed to the outside face of studs and one layer of 13 mm plasterboard fixed to the outside face of the concrete panel,
has an Rw + Ctr of not less than 50, if constructed in accordance with Figure 10.7.6c.
(5) A 125 mm thick concrete panel with—
a row of 64 mm steel studs at 600 mm centres, spaced 20 mm from the concrete panel; and
70 mm polyester insulation with a density of 9 kg/m3, positioned between studs; and
one layer of 13 mm plasterboard fixed to the outside face of the studs,
has an Rw + Ctr of not less than 50, if constructed in accordance with Figure 10.7.6d.
Figure 10.7.6a 150 mm thick plain off form concrete
Figure 10.7.6b 200 mm thick concrete panel
Figure 10.7.6c 100 mm thick concrete panel
Figure 10.7.6d 125 mm thick concrete panel