11.2.3 Ramps

Part 11.2 Stairway and ramp construction · NCC 2019: 3.9.1.3

Open 11.2.3 on NCC Online ↗

An external ramp serving an external doorway or a ramp within a building must—

be designed to take loading forces in accordance with AS/NZS 1170.1; and

have a gradient not steeper than 1:8; and

be provided with landings complying with 11.2.5 at the top and bottom of the ramp and at intervals not greater than 15 m.

Notes: Livable housing design

Where an external ramp is provided for the purposes of compliance with the ABCB Standard for Livable Housing Design, the requirements of that Standard apply.

Changed in NCC 2025. See ABCB Housing Provisions 2025 11.2.3, or show what changed.

An external ramp serving an external doorway or a ramp … 1170.1; and have a gradient not steeper than 1:8; and except for threshold ramps, step ramps and kerb ramps, be provided with landings complying with 11.2.5 at the top … for Livable Housing Design, the requirements of that Standard apply.

Removed words are struck through; added words are highlighted. Comparison of the text only.