Housing Provisions clause · ABCB Housing Provisions 2022

11.2.4 Slip resistance

Part 11.2 Stairway and ramp construction · NCC 2019: 3.9.1.4

Open 11.2.4 on NCC Online ↗

(1) The requirements for slip-resistance treatment to stair treads, ramps and landings are as set out in (2), (3) and (4).

(2) Treads must have—

a surface with a slip-resistance classification not less than that listed in Table 11.2.4 when tested in accordance with AS 4586; or

a nosing strip with a slip-resistance classification not less than that listed in Table 11.2.4 when tested in accordance with AS 4586.

(3) The floor surface of a ramp must have a slip-resistance classification not less than that listed in Table 11.2.4 when tested in accordance with AS 4586.

(4) Landings, where the edge leads to the flight below, must have—

a surface with a slip-resistance classification not less than that listed in Table 11.2.4 when tested in accordance with AS 4586, for not less than 190 mm from the stair nosing; or

a nosing strip with a slip-resistance classification not less than that listed in Table 11.2.4 when tested in accordance with AS 4586.

Table 11.2.4 Slip-resistance classification

Application

Dry surface conditions

Wet surface conditions

Ramp not steeper than 1:8

P4 or R10

P5 or R12

Tread surface

P3 or R10

P4 or R11

Nosing or landing edge strip

P3

P4

Tables

Changed in NCC 2025. See ABCB Housing Provisions 2025 11.2.4, or show what changed.

(1) The requirements for slip-resistance treatment to stair treads, ramps … accordance with AS 4586. (3) The floor surface of a ramp ramp, other than a threshold ramp, must have a slip-resistance classification not less than that listed … P4 or R11 Nosing or landing edge strip P3 P4

Removed words are struck through; added words are highlighted. Comparison of the text only.

Defined terms used