Housing Provisions clause · ABCB Housing Provisions 2022

12.3.4 Bracing

Part 12.3 Attachment of framed decks and balconies to external walls of buildings using a waling plate · NCC 2019: 3.10.6.4

Open 12.3.4 on NCC Online ↗

Where a deck or balcony is more than 1 m off the ground when measured from the uppermost surface of the deck or balcony at any point to the top of any supporting footing, bracing must be installed as follows:

Two diagonally opposed 30 x 0.8 mm galvanized steel straps must be installed across the top or underside of the joists and be attached using one fixing at—

each joist or equivalent framing member; and

the waling plate.

A secondary set of 30 x 0.8 mm steel straps must be installed using one fixing at each joist or equivalent framing member in accordance with Figure 12.3.4 where the deck or balcony extends more than 4 m from the external wall.

The steel straps must—

be continuous and extend diagonally at an angle between 30° to 60°; and

span not more than 4 m when measured along a line at a right angle from the external wall.

Fixings for the steel straps must be—

for timber framing, 50 x 3.15 hot-dipped galvanized flat head ring shank or flat head deformed nail; or

for steel framing, 8-18 self embedding head or wafer head screws.

Where the deck or balcony is located within a severe corrosion environment, the bracing and fixings must comply with Table 6.3.9a, 6.3.9b and 6.3.9c.

Figure 12.3.4 Bracing of decks and balconies

Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 12.3.4.

Defined terms used