12.3.4 Bracing
Part 12.3 Attachment of framed decks and balconies to external walls of buildings using a waling plate · NCC 2019: 3.10.6.4
Where a deck or balcony is more than 1 m off the ground when measured from the uppermost surface of the deck or balcony at any point to the top of any supporting footing, bracing must be installed as follows:
Two diagonally opposed 30 x 0.8 mm galvanized steel straps must be installed across the top or underside of the joists and be attached using one fixing at—
each joist or equivalent framing member; and
the waling plate.
A secondary set of 30 x 0.8 mm steel straps must be installed using one fixing at each joist or equivalent framing member in accordance with Figure 12.3.4 where the deck or balcony extends more than 4 m from the external wall.
The steel straps must—
be continuous and extend diagonally at an angle between 30° to 60°; and
span not more than 4 m when measured along a line at a right angle from the external wall.
Fixings for the steel straps must be—
for timber framing, 50 x 3.15 hot-dipped galvanized flat head ring shank or flat head deformed nail; or
for steel framing, 8-18 self embedding head or wafer head screws.
Where the deck or balcony is located within a severe corrosion environment, the bracing and fixings must comply with Table 6.3.9a, 6.3.9b and 6.3.9c.
Figure 12.3.4 Bracing of decks and balconies