8.3.3 Fully framed glazing installed in perimeter of buildings
Part 8.3 Glass · NCC 2019: 3.6.3
Fully framed (supported on all sides) monolithic annealed glass installed in the perimeter of buildings must comply with—
if the building is located in an area with a wind class not exceeding N1 – Table 8.3.3a; or
if the building is located in an area with a wind class not exceeding N2 – Table 8.3.3b; or
if the building is located in an area with a wind class not exceeding N3 – Table 8.3.3c.
Table 8.3.3a Glass thickness for wind class not exceeding N1: monolithic annealed glass (mm)
Edge (mm)
300
450
600
750
900
1050
1200
1350
1500
1650
300
3
3
3
3
3
3
3
3
3
3
450
3
3
3
3
3
3
3
3
3
3
600
3
3
3
3
3
3
3
3
4
4
750
3
3
3
3
3
3
4
4
4
4
900
3
3
3
3
3
4
4
4
4
4
1050
3
3
3
3
4
4
4
4
4
4
1200
3
3
3
4
4
4
4
4
4
4
1350
3
3
3
4
4
4
4
4
4
4
1500
3
3
4
4
4
4
4
4
4
4
1650
3
3
4
4
4
4
4
4
4
4
1800
3
3
4
4
4
4
4
4
4
4
1950
3
4
4
4
4
4
4
4
4
4
2100
3
4
4
4
4
4
4
4
4
4
2250
3
4
4
4
4
4
4
4
4
4
2400
3
4
4
4
4
4
5
5
4
5
2550
3
4
4
4
4
4
5
5
4
5
2700
3
4
4
4
4
4
5
5
6
5
Table 8.3.3b Glass thickness for wind class not exceeding N2: monolithic annealed glass (mm)
Edge (mm)
300
450
600
750
900
1050
1200
1350
1500
1650
300
3
3
3
3
3
3
3
3
3
3
450
3
3
3
3
3
3
3
3
3
3
600
3
3
3
3
3
3
3
3
4
4
750
3
3
3
3
3
3
4
4
4
4
900
3
3
3
3
3
4
4
4
4
4
1050
3
3
3
3
4
4
4
4
4
4
1200
3
3
3
4
4
4
4
4
4
4
1350
3
3
3
4
4
4
4
4
4
4
1500
3
3
4
4
4
4
4
4
4
4
1650
3
3
4
4
4
4
4
4
4
4
1800
3
3
4
4
4
4
4
4
4
5
1950
3
4
4
4
4
4
4
4
5
5
2100
3
4
4
4
4
4
4
5
5
6
2250
3
4
4
4
4
4
5
5
5
6
2400
3
4
4
4
4
4
5
5
5
6
2550
3
4
4
4
4
4
5
5
5
6
2700
3
4
4
4
5
5
5
5
6
6
Table 8.3.3c Glass thickness for wind class not exceeding N3: monolithic annealed glass (mm)
Edge (mm)
300
450
600
750
900
1050
1200
1350
1500
1650
300
3
3
3
3
3
3
3
3
3
3
450
3
3
3
3
3
3
3
3
3
3
600
3
3
3
3
3
3
3
3
4
4
750
3
3
3
3
3
3
4
4
4
4
900
3
3
3
3
3
4
4
4
4
4
1050
3
3
3
3
4
4
4
4
5
5
1200
3
3
3
4
4
4
4
5
5
5
1350
3
3
3
4
4
4
5
5
5
5
1500
3
3
4
4
4
5
5
5
5
6
1650
3
3
4
4
4
5
5
6
6
6
1800
3
3
4
4
4
5
5
6
6
6
1950
3
4
4
4
5
5
5
6
6
6
2100
3
4
4
5
5
5
6
6
6
8
2250
3
4
4
5
5
5
6
6
8
8
2400
3
4
4
5
5
5
6
6
8
8
2550
3
4
4
5
5
5
6
6
8
8
2700
3
4
4
5
6
6
6
8
8
8
Tables
- Table 8.3.3a Glass thickness for wind class not exceeding N1: monolithic annealed glass (mm)
- Table 8.3.3b Glass thickness for wind class not exceeding N2: monolithic annealed glass (mm)
- Table 8.3.3c Glass thickness for wind class not exceeding N3: monolithic annealed glass (mm)