South Australia variation · ABCB Housing Provisions 2022

SA 9.2.9 Allowable encroachments

Part 9.2 Fire separation of external walls · varies 9.2.9 Allowable encroachments

Open on NCC Online ↗

Delete clause 9.2.9 and insert SA 9.2.9 as follows:

(1) An encroachment is any construction between—

the external wall of the building and the allotment boundary other than a boundary adjoining a road or other public space; or

the external walls of two buildings on the same allotment; or

the external wall of the building and a brush fence.

(2) For the purposes of (1), an encroachment related to any external wall of—

a Class 10a building required to comply with 9.2.4; or

a Class 1 building.

(3) The encroachments allowed within 900 mm of an allotment boundary or within 1.8 m of another building on the same allotment or within 3 m of a brush fence are—

non-combustible fascias, gutters and downpipes; and

light fittings, electricity or gas meters, aerials or antennas; and

pergolas, sun blinds or water tanks; and

unroofed terraces, landings, steps and ramps, not more than 1 m in height.

(4) Except as permitted by (5) or not permitted by (6), encroachments allowed up to but not closer than 450 mm from an allotment boundary or up to but not closer than 900 mm from another building on the same allotment or associated encroachments of another building on the same allotment are—

combustible fascias, gutters and downpipes (see Figures 9.2.9a, 9.2.9b and 9.2.9c); and

eaves with non-combustible roof cladding and non-combustible lining; and

flues, chimneys, pipes, domestic fuel tanks, cooling or heating appliances or other services.

(5) Eaves with non-combustible roof cladding and non-combustible soffit or lining may encroach within 450 mm of the allotment boundary where the external walls of a building are located not less than 900 mm from the allotment boundary and the walls are positioned at an angle of not less than 20 degrees and not more than 70 degrees to the allotment boundary or other building and the eaves only encroach at the corner of the roof (see SA Figure 9.2.9).

(6) Fascias listed in (4)(a) must not be built within 3 m of a brush fence.

Insert SA figure (9.2.9) 9.2.9 as follows:

SA Figure 9.2.9: Concession for encroachment of eaves

Changed in NCC 2025. See ABCB Housing Provisions 2025 SA 9.2.9, or show what changed.

Delete clause 9.2.9 and insert SA 9.2.9 as follows: (1) … steps and ramps, not more than 1 m in height. open carports and verandahs that comply with SA 9.2.8. (4) Except as permitted by (5) or not permitted by … as follows: SA Figure 9.2.9: Concession for encroachment of eaves

Removed words are struck through; added words are highlighted. Comparison of the text only.