Table · ABCB Housing Provisions 2022
Table 5.6.5d Corrosion protection for wall ties
Part 5.6 Masonry components and accessories
| Exposure condition | Tie specification (minimum corrosion protection) |
|---|---|
| Areas less than 1km from breaking surf; or less than 100 m from salt water not subject to breaking surf; or within heavy industrial areas. | Grade 316L stainless steel; or engineered polymer complying with the requirements of AS 2699.1. |
| Areas 1km or more but less than 10km from breaking surf; or 100m or more but less than 1km from salt water not subject to breaking surf. | Sheet steel and bar ties galvanised after manufacture - 470 g/m2 on each side; or galvanised wire ties - 470 g/m2 coating mass; or Grade 304L stainless steel. |
| All other areas | Galvanised sheet steel - 300 g/m2 coating on each side; or sheet steel ties galvanised after manufacture - 300 g/m2 on each side. |
Table for 5.6.5 Wall ties
Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 Table 5.6.5d.