A5G6 Fire hazard properties
Part A5 Documentation of design and construction · NCC 2019: A5.5
Where a Deemed-to-Satisfy Provision requires a building component or assembly to have a fire hazard property it must be determined as follows:
For average specific extinction area, critical radiant flux and Flammability Index, as defined in Specification 1.
For Smoke-Developed Index and Spread-of-Flame Index, in accordance with Specification 3.
For a material’s group number or smoke growth rate index (SMOGRARC), in accordance with S7C4(2).
Changed in NCC 2025. See NCC 2025 Volume One A5G6, or show what changed.
Where (1) Subject to (3), where a Deemed-to-Satisfy Provision requires a building component material, component, or assembly to have a fire hazard property it must be determined as follows: For average specific extinction area, critical radiant flux and Flammability Index, as defined smoke development rate, in Specification 1. accordance with AS ISO 9239.1. For Smoke-Developed Index and Spread-of-Flame Index, in accordance with Specification 3. AS/NZS 1530.3. For a material’s group number or number, average specific extinction area and smoke growth rate index (SMOGRARC), in accordance with S7C4(2). AS 5637.1. For Flammability Index, in accordance with AS 1530.2. (2) Subject to (4) and (5), where a Deemed-to-Satisfy Provision requires a building material, component, or assembly to be non-combustible, its combustibility may be determined in accordance with AS 1530.1 or C2D10(5). (3) A building material, component, or assembly is deemed to have a fire hazard property if — it is identical with a prototype that has been tested in accordance with (1) and the fire hazard property achieved by the prototype is confirmed in a report issued from an Accredited Testing Laboratory that — describes the method and conditions of the test and form of construction of the tested prototype in full; and confirms that the application of restraint to the prototype complies with the test standard; or it differs in only a minor degree from a prototype tested under (a) and a report from an Accredited Testing Laboratory — confirms that the building product, component, or assembly can achieve the fire hazard property despite the minor departures from the tested prototype; and describes the materials, construction, conditions of restraint and other limitations which are necessary to achieve the fire hazard property. (4) A building material is deemed to be non-combustible if — it is identical with a material that has been tested in accordance with AS 1530.1 and has not been deemed combustible, as confirmed in a report issued from an Accredited Testing Laboratory; or it is deemed non-combustible in accordance with C2D10(5); or it differs in only a minor degree to a material tested under (a) and a report from an Accredited Testing Laboratory — confirms that the material can achieve the attribute of being non-combustible despite the minor departures from the tested material; and describes any limitations which are necessary to achieve the attribute of being non-combustible. (5) A building component or assembly is deemed to be non-combustible if it is constructed wholly of materials that are deemed to be non-combustible. Notes Until adoption of the next edition of the NCC, determination need not be undertaken by an Accredited Testing Laboratory.
Removed words are struck through; added words are highlighted. Comparison of the text only.