Point of connection
Any of the following:
For a cold water service, means the point where the cold water service connects to—
the Network Utility Operator's water supply system; or
the point of isolation to an alternative water source where there is no Network Utility Operator's water supply available or is not utilised.
For a heated water service, means the point where the water heater connects to the cold water service downstream of the isolation valve.
For sanitary drainage, means the point where the on-site sanitary drainage system connects to—
the Network Utility Operator's sewerage system; or
an on-site wastewater management system.
For sanitary plumbing, means the point where the sanitary plumbing system connects to the sanitary drainage system.
For a rainwater service, means the point where the rainwater service—
connects to the point of isolation for the rainwater storage; or
draws water from the rainwater storage.
For stormwater disposal, means the point where the on-site stormwater drainage system connects to—
the Network Utility Operator's stormwater system; or
an approved on-site disposal system.
For a fire-fighting water service, means the point where the service connects to—
a cold water service, downstream of a backflow prevention device; or
the Network Utility Operator's water supply system; or
the point of isolation to an alternative water source.
Notes
A domestic fire sprinkler service conforming to FPAA101D is considered part of the cold water service.