F4D2 Facilities in residential buildings
Part F4 Sanitary and other facilities · NCC 2019: F2.1
(1) For facilities in Class 2 buildings, the following applies:
Within each sole-occupancy unit, provide—
a kitchen sink and facilities for the preparation and cooking of food; and
a bath or shower; and
a closet pan; and
a washbasin.
For laundry facilities, provide either—
in each sole-occupancy unit—
clothes washing facilities, comprising at least one washtub and a space for a washing machine; and
clothes drying facilities comprising clothes line or a hoist with not less than 7.5 m of line, or space for one heat operated drying cabinet or appliance in the same room as the clothes washing facilities; or
a separate laundry for each 4 sole-occupancy units, or part thereof, that must comprise—
clothes washing facilities, comprising at least one washtub and a space for a washing machine; and
clothes drying facilities comprising clothes line or a hoist with not less than 7.5 m of line per sole-occupancy unit, or space for one heat operated drying cabinet or appliance.
For the purposes of (a) and (b), a kitchen sink or washbasin must not be counted as a laundry washtub.
(2) For facilities in Class 3 buildings other than residential care buildings, the following applies:
For residents in each building or group of buildings, for each 10 residents for whom private facilities are not provided, provide—
a bath or shower; and
a closet pan; and
a washbasin.
Notwithstanding (a), if one urinal is provided for each 25 males up to 50 and one additional urinal for each additional 50 males or part thereof, one closet pan for each 12 males may be provided.
Facilities for employees must be provided in accordance with F4D4.
Facilities required by (a), (b) or (c) need not be situated in the same building.
(3) For facilities in Class 3 residential care buildings, the following applies:
For residents in each building or group of buildings, provide—
a shower, closet pan and wash basin for each 8 residents or part thereof where private facilities are not provided; and
a suitable bath for each 30 residents or part thereof.
For the purposes of (a), urinals must not be taken into consideration in calculating the number of facilities.
(4) For facilities in a Class 4 part of a building, the following applies:
For the sole-occupancy unit, provide—
a kitchen sink and facilities for the preparation and cooking of food; and
a bath or shower; and
a closet pan; and
a washbasin; and
clothes washing facilities, comprising a washtub and space in the same room for a washing machine; and
a clothes line or hoist, or space for a heat-operated drying cabinet or similar appliance for the exclusive use of the occupants.
For the purposes of (a), a kitchen sink or washbasin must not be counted as a laundry washtub.
(5) For facilities in Class 9c buildings, the following applies:
For residents in each building or group of buildings, provide—
a closet pan and wash basin for each 6 residents or part thereof where private facilities are not provided; and
a shower for each 7 residents or part thereof for where private facilities are not provided; and
a suitable bath, fixed or mobile.
In addition to the facilities required by (a), provide—
one kitchen or other adequate facility for the preparation and cooking or reheating of food including a kitchen sink and washbasin; and
laundry facilities for the cleansing and drying of linen and clothing or adequate facilities for holding and dispatch or treatment of soiled linen and clothing and the like and the receipt and storage of clean linen; and
one clinical hand washing basin for each 16 residents or part thereof.
For the purposes of (a), urinals must not be taken into consideration in calculating the number of facilities.