NCC 2022 Volume One
Part I2 Public transport buildings
15 clauses · Open on NCC Online ↗
- I2D1 Application of PartThe Deemed-to-Satisfy Provisions of this Part apply to the passenger use areas of a Class 9b or Class 10 building used for public transport. (2) The…
- I2D2 AccesswaysAn accessway must comply with AS 1428.2. (2) If an accessway branches into 2 or more parallel tracks— the ends of each track must be on the main…
- I2D3 RampsA ramp forming part of an accessway must comply with clause 8 of AS 1428.2. (2) The requirements of D4D12(a) do not apply to Class 9b or Class 10…
- I2D4 Handrails and grabrailsA handrail must comply with clause 10.1 of AS 1428.2. (2) Handrails must be placed along an accessway wherever passengers are likely to require…
- I2D5 Doorways and doorsDoorways and doors must comply with clause 11 (except clause 11.5.2) of AS 1428.2.
- I2D6 LiftsLift facilities must comply with AS 1735.12.
- I2D7 StairwaysStairs must comply with— clause 9.1 of AS 1428.1, including the notes; and clause 9.2 of AS 1428.1; and clauses 13.2, 13.3 and Figures 8 and 9 of AS…
- I2D8 Unisex accessible toiletIf toilets are provided, there must be at least one unisex accessible toilet without an airlock that complies with AS 1428.1 clause 10, sanitary…
- I2D9 Location of accessible toiletsAccessible toilets must be in the same location as other toilets.
- I2D10 Symbols and signsThe international symbols for accessibility and deafness in accordance with clauses 14.2 and 14.3 of AS 1428.1 must be used to identify an accessway…
- I2D11 Tactile ground surface indicatorsTactile ground surface indicators must be installed in accordance with AS 1428.4 on an accessway and must indicate changes of direction in…
- I2D12 LightingAny lighting provided must comply with minimum levels of maintenance illumination for various situations shown in the notes to clause 19.1 of AS…
- I2D13 Hearing augmentationIf a public address system is installed, it must comply with clause 21.1 of AS 1428.2.
- I2D14 Emergency warning systemsIf an emergency warning system is installed, it must comply with clauses 18.2.1, 18.2.2 and 18.2.3 of AS 1428.2. (2) In the event of an emergency,…
- I2D15 ControlsControls must comply with clause 11 of AS 1428.1.