QLD G1P2 Swimming pool access and water recirculation systems
Part G1 Minor structures and components · varies G1P2 Swimming pool access and water recirculation systems
Delete clause G1P2 and insert QLD G1P2 as follows:
A swimming pool water recirculation system must incorporate safety measures to avoid entrapment of, or injury to, a person.
Applications
QLD G1P2 only applies to a swimming pool with a depth of water more than 300 mm.
Changed in NCC 2025. See NCC 2025 Volume One QLD G1P2, or show what changed.
Delete clause G1P2 and insert QLD G1P2 as follows: (1) Barriers and fences for swimming pools are regulated by the Building Act 1975 (QLD), Building Regulation 2021 (QLD) and the Queensland Development Code MP 3.4 — Swimming pool barriers. (2) A swimming pool water recirculation system must incorporate safety measures to avoid entrapment of, or injury to, to a person. Applications QLD G1P2 only applies to a swimming pool with a depth of water more than 300 mm. Barriers and fences for swimming pools are regulated by the Building Act 1975 (QLD), Building Regulation 2021 (QLD) and the Queensland Development Code MP 3.4 — Swimming pool barriers.
Removed words are struck through; added words are highlighted. Comparison of the text only.
The national clause
Other states and territories
- VIC Delete clause G1P2 and insert VIC G1P2 as follows: (1) A barrier must be provided to a swimming pool and must— be…
- NSW Delete clause G1P2 and insert NSW G1P2 as follows: (1) A barrier must be provided to a swimming pool and must— be…
- NT Delete clause G1P2 and insert NT G1P2 as follows: A swimming pool water recirculation system must incorporate safety…
- SA Delete clause G1P2 and insert SA G1P2 as follows: (1) A barrier must be provided to a swimming pool and must— be…
- TAS Delete clause G1P2 and insert TAS G1P2 as follows: (1) A barrier must be provided to a swimming pool and must— be…