S28C6 Acceptable forms of construction for walls — autoclaved aerated concrete
Specification 28 Sound insulation for building elements · NCC 2019: Spec F5.2: Table 2
(1) Acceptable forms of construction for autoclaved aerated concrete walls are set out in (2) to (5).
(2) A 75 mm thick autoclaved aerated concrete wall panel with—
a row of 64 mm steel studs at 600 mm centres, spaced 20 mm from the autoclaved aerated concrete wall panel; and
75 mm thick glass wool insulation with a density of 11 kg/m3 positioned between studs; and
one layer of 10 mm moisture resistant plasterboard or 13 mm fire protective grade plasterboard fixed to outside face of studs and outside face of autoclaved aerated concrete wall panel,
has an Rw + Ctr of not less than 50 and an Rw of not less than 50, if constructed as shown in Figure S28C6a.
(3) A 75 mm thick autoclaved aerated concrete wall panel with—
a row of 64 mm steel studs at 600 mm centres, spaced 35 mm from the autoclaved aerated concrete panel wall; and
28 mm metal furring channels fixed to the outside face of the autoclaved aerated concrete wall panel, with 50 mm thick polyester insulation with a density of 9 kg/m3 positioned between furring channels and one layer of 13 mm fire protective grade plasterboard fixed to furring channels; and
105 mm thick glass wool insulation with a density of 7 kg/m3 positioned between studs; and
one layer of 13 mm fire protective grade plasterboard fixed to the outside face of the studs,
has an Rw + Ctr of not less than 50 and an Rw of not less than 50, if constructed as shown in Figure S28C6b.
(4) Two leaves of 75 mm autoclaved aerated concrete wall panel with—
a cavity not less than 30 mm between panels containing 50 mm glass wool insulation with a density of 11 kg/m3; and
one layer of 10 mm plasterboard fixed to outside face of each panel,
has an Rw + Ctr of not less than 50 and an Rw of not less than 50, if constructed as shown in Figure S28C6c.
(5) A 75 mm thick autoclaved aerated concrete wall panel with—
one layer of 10 mm moisture resistant plasterboard on one face; and
28 mm metal furring channels and resilient mounts, 75 mm polyester insulation with a density of 9 kg/m3 and 13 mm fire-protective grade plasterboard fixed to the other face,
has an Rw of not less than 50, if constructed as shown in Figure S28C6d.
Figure S28C6a 75 mm thick autoclaved aerated concrete wall panel (method 1)
Figure S28C6b 75 mm thick autoclaved aerated concrete wall panel (method 2)
Figure S28C6c Two leaves of 75 mm autoclaved aerated concrete wall panel
Figure S28C6d 75 mm thick autoclaved aerated concrete wall panel (method 3)