Specification clause · NCC 2022 Volume One

S37C7 Shading

Specification 37 Calculation of U-Value and solar admittance · NCC 2019: Spec J1.5a: 7

Open S37C7 on NCC Online ↗

For the purpose of calculating solar admittance, the shading multiplier is—

for shading provided by an external permanent projection that extends horizontally on both sides of the glazing for the same projection distance P, as shown in Figure S37C7—

the value in Table S37C7a for shading on the northern, eastern or western aspects; or

the value in Table S37C7b for shading on the southern aspect; or

0.35 for shading that is provided by an external shading device such as a shutter, blind, vertical or horizontal building screen with blades, battens or slats, which—

is capable of restricting at least 80% of summer solar radiation; and

if adjustable, will operate automatically in response to the level of solar radiation.

Table S37C7a Shading multipliers — Northern, eastern and western aspects

G/H

P/H = 0

P/H = 0.1

P/H = 0.2

P/H = 0.3

P/H = 0.4

P/H = 0.5

P/H = 0.6

P/H = 0.7

P/H = 0.8

P/H = 0.9

P/H = 1

0

1.00

0.90

0.80

0.72

0.64

0.57

0.51

0.46

0.41

0.38

0.35

0.1

1.00

0.95

0.89

0.81

0.74

0.66

0.59

0.52

0.47

0.42

0.40

0.2

1.00

0.98

0.94

0.89

0.82

0.75

0.68

0.62

0.56

0.51

0.47

0.3

1.00

1.00

0.97

0.94

0.89

0.84

0.78

0.72

0.66

0.61

0.57

0.4

1.00

1.00

0.99

0.97

0.94

0.90

0.86

0.82

0.77

0.73

0.68

0.5

1.00

1.00

1.00

0.99

0.97

0.95

0.92

0.90

0.86

0.83

0.79

Table S37C7b Shading multipliers — Southern aspect

G/H

P/H = 0

P/H = 0.1

P/H = 0.2

P/H = 0.3

P/H = 0.4

P/H = 0.5

P/H = 0.6

P/H = 0.7

P/H = 0.8

P/H = 0.9

P/H = 1

0

1.00

0.93

0.87

0.82

0.77

0.73

0.69

0.65

0.62

0.60

0.58

0.1

1.00

0.97

0.93

0.88

0.84

0.79

0.75

0.71

0.67

0.64

0.62

0.2

1.00

0.98

0.96

0.93

0.89

0.85

0.81

0.77

0.73

0.70

0.68

0.3

1.00

0.99

0.98

0.96

0.93

0.90

0.87

0.83

0.80

0.77

0.74

0.4

1.00

1.00

0.99

0.98

0.96

0.94

0.91

0.89

0.86

0.84

0.81

0.5

1.00

1.00

0.99

0.99

0.98

0.96

0.95

0.93

0.91

0.90

0.88

Figure S37C7 Permanent external shading – measurement of P, G and H

Tables

Changed in NCC 2025. See NCC 2025 Volume One S37C7, or show what changed.

For the purpose of calculating solar admittance, the shading multiplier for each glazing element is the lesser of — for shading provided by an external permanent projection that extends horizontally on both sides of the glazing for the same projection project distance P, as shown in Figure S37C7 S37C7a — the value in Table S37C7a for shading on the northern, eastern or western aspects; or the value in Table S37C7b for shading on the southern aspect; or for shading provided by an external permanent projection that extends vertically for the height of the glazing for the same projection distance D, as shown in Figure S37C7b — the value in Table S37C7c for shading on the northern aspect; or the value in Table S37C7d for shading on the western aspect; or the value in Table S37C7e for shading on the eastern aspect; or 1.0 for shading on the southern aspect; or 0.35 for shading … in response to the level of solar radiation. Table S37C7a Shading Horizontal shading multipliers — Northern, eastern and western aspects G/H P/H = … 0.99 0.97 0.95 0.92 0.90 0.86 0.83 0.79 Table S37C7b Shading Horizontal shading multipliers — Southern aspect G/H P/H = 0 P/H = … 1.00 0.99 0.99 0.98 0.96 0.95 0.93 0.91 0.90 0.88 Table S37C7c Vertical shading multipliers — Northern aspect Climate zone D W = 1.7 H W = H W = 0.7 H W = 0.5 H 1, 2, 3, 5, 6 0.1 W 0.91 0.90 0.90 0.90 1, 2, 3, 5, 6 0.3 W 0.85 0.83 0.82 0.81 1, 2, 3, 5, 6 0.5 W 0.82 0.78 0.76 0.74 1, 2, 3, 5, 6 0.7 W 0.81 0.76 0.73 0.70 4 0.1 W 0.91 0.91 0.90 0.90 4 0.3 W 0.87 0.84 0.83 0.82 4 0.5 W 0.84 0.80 0.78 0.76 4 0.7 W 0.83 0.78 0.75 0.73 7 0.1 W 0.92 0.91 0.91 0.90 7 0.3 W 0.87 0.85 0.83 0.82 7 0.5 W 0.86 0.82 0.79 0.78 7 0.7 W 0.85 0.80 0.78 0.75 8 0.1 W 0.92 0.92 0.91 0.91 8 0.3 W 0.90 0.88 0.86 0.85 8 0.5 W 0.91 0.87 0.85 0.83 8 0.7 W 0.91 0.88 0.86 0.84 Table S37C7d Vertical shading multipliers — Western aspect Climate zone D W = 1.7 H W = H W = 0.7 H W = 0.5 H 1, 2, 3, 5, 6 0.1 W 0.93 0.91 0.90 0.90 1, 2, 3, 5, 6 0.3 W 0.87 0.85 0.84 0.84 1, 2, 3, 5, 6 0.5 W 0.85 0.82 0.80 0.79 1, 2, 3, 5, 6 0.7 W 0.83 0.79 0.77 0.75 4 0.1 W 0.93 0.90 0.90 0.89 4 0.3 W 0.88 0.86 0.85 0.84 4 0.5 W 0.87 0.84 0.82 0.81 4 0.7 W 0.86 0.83 0.81 0.79 7 0.1 W 0.96 0.95 0.95 0.95 7 0.3 W 0.94 0.94 0.94 0.93 7 0.5 W 0.94 0.93 0.93 0.93 7 0.7 W 0.94 0.93 0.93 0.92 8 0.1 W 0.93 0.90 0.89 0.89 8 0.3 W 0.90 0.88 0.87 0.87 8 0.5 W 0.90 0.88 0.87 0.86 8 0.7 W 0.90 0.89 0.87 0.86 Table S37C7e Vertical shading multipliers — Eastern aspect Climate zone D W = 1.7 H W = H W = 0.7 H W = 0.5 H 1, 2, 3, 5, 6 0.1 W 0.94 0.94 0.93 0.93 1, 2, 3, 5, 6 0.3 W 0.90 0.89 0.88 0.87 1, 2, 3, 5, 6 0.5 W 0.88 0.85 0.84 0.83 1, 2, 3, 5, 6 0.7 W 0.87 0.83 0.81 0.79 4 0.1 W 0.94 0.93 0.92 0.92 4 0.3 W 0.91 0.89 0.89 0.88 4 0.5 W 0.90 0.88 0.86 0.85 4 0.7 W 0.89 0.87 0.85 0.83 7 0.1 W 0.95 0.94 0.94 0.93 7 0.3 W 0.91 0.92 0.91 0.91 7 0.5 W 0.93 0.91 0.90 0.89 7 0.7 W 0.93 0.91 0.90 0.88 8 0.1 W 0.94 0.93 0.93 0.92 8 0.3 W 0.94 0.93 0.93 0.92 8 0.5 W 0.95 0.94 0.93 0.92 8 0.7 W 0.95 0.95 0.94 0.93 Figure S37C7 S37C7a Permanent external horizontal shading – measurement of P, G and H Figure S37C7b Permanent external vertical shading – measurement of D, W and H

Removed words are struck through; added words are highlighted. Comparison of the text only.

Defined terms used