Table · NCC 2022 Volume One
Table D4D2b Requirements for access for people with a disability – sole-occupancy units in a Class 3 or 9c building
Part D4 Access for people with a disability
| Total number of sole-occupancy units | Number required to be accessible |
|---|---|
| 1 to 10 | 1 |
| 11 to 40 | 2 |
| 41 to 60 | 3 |
| 61 to 80 | 4 |
| 81 to 100 | 5 |
| 101 to 200 | 5 sole-occupancy units plus 1 additional sole-occupancy unit for each additional 25 units or part thereof in excess of 100. |
| 201 to 500 | 9 sole-occupancy units plus 1 additional sole-occupancy unit for each additional 30 units or part thereof in excess of 200. |
| More than 500 | 19 sole-occupancy units plus 1 additional sole-occupancy unit for each additional 50 units or part thereof in excess of 500. |
Table Notes
In a Class 3 building, not more than 2 required accessible sole-occupancy units may be located adjacent to each other.
In a Class 3 or 9c building where more than 2 accessible sole-occupancy units are required, they must be representative of the range of rooms available.
Table for D4D2 General building access requirements
Same wording in NCC 2025 Volume One. See NCC 2025 Volume One Table D4D2b.