Table · NCC 2022 Volume One

Table J4D5 Roof lights – Total system SHGC

Part J4 Building fabric

Open Table J4D5 on NCC Online ↗
Roof light shaft index Note 1Total area of roof lights up to 3.5% of the floor area of the room or spaceTotal area of roof lights more than 3.5% and up to 5% of the floor area of the room or space
<1.0≤ 0.45≤ 0.29
≥ 1.0 to < 2.5≤ 0.51≤ 0.33
≥ 2.5≤ 0.76≤ 0.49

Table Notes

The roof light shaft index is determined by measuring the distance from the centre of the shaft at the roof to the centre of the shaft at the ceiling level and dividing it by the average internal dimension of the shaft opening at the ceiling level (or the diameter for a circular shaft) in the same units of measurement.

The area of a roof light is the area of the roof opening that allows light to enter the building.

The total area of roof lights is the combined area for all roof lights serving the room or space.

Table for J4D5 Roof lights

Same wording in NCC 2025 Volume One. See NCC 2025 Volume One Table J4D5.

Defined terms used