Table · NCC 2022 Volume One

Table S43C2 Minimum distance of building to classified vegetation

Specification 43 Bushfire protection for certain Class 9 buildings

Open Table S43C2 on NCC Online ↗
Vegetation classificationSlopeMinimum distance (m) of the building to classified vegetation
High riskUpslope and flat land60
High riskDownslope max 20 degrees110
Medium riskUpslope and flat land40
Medium riskDownslope max 20 degrees80
Low riskUpslope and flat land30
Low riskDownslope max 20 degrees50

Table Notes

Table values are based on a Fire Danger Index of 100 in accordance with AS 3959.

High risk equates to vegetation classification of forest and woodland in accordance with AS 3959.

Medium risk equates to vegetation classification of scrub and rainforest in accordance with AS 3959.

Low risk equates to vegetation classification of shrubland, mallee/mulga and grassland in accordance with AS 3959.

Table for S43C2 Separation from classified vegetation

Same wording in NCC 2025 Volume One. See NCC 2025 Volume One Table S43C2.