Table · NCC 2022 Volume One
Table S43C2 Minimum distance of building to classified vegetation
Specification 43 Bushfire protection for certain Class 9 buildings
| Vegetation classification | Slope | Minimum distance (m) of the building to classified vegetation |
|---|---|---|
| High risk | Upslope and flat land | 60 |
| High risk | Downslope max 20 degrees | 110 |
| Medium risk | Upslope and flat land | 40 |
| Medium risk | Downslope max 20 degrees | 80 |
| Low risk | Upslope and flat land | 30 |
| Low risk | Downslope max 20 degrees | 50 |
Table Notes
Table values are based on a Fire Danger Index of 100 in accordance with AS 3959.
High risk equates to vegetation classification of forest and woodland in accordance with AS 3959.
Medium risk equates to vegetation classification of scrub and rainforest in accordance with AS 3959.
Low risk equates to vegetation classification of shrubland, mallee/mulga and grassland in accordance with AS 3959.
Table for S43C2 Separation from classified vegetation
Same wording in NCC 2025 Volume One. See NCC 2025 Volume One Table S43C2.