A5G4 Evidence of suitability ─ Volume Three (PCA)
Part A5 Documentation of design and construction · NCC 2019: A5.3
(1) Any product that is intended for use in contact with drinking water must comply with the relevant requirements of AS/NZS 4020, verified in the form of either—
a test report provided by an Accredited Testing Laboratory, in accordance with AS/NZS 4020; or
a WaterMark Licence issued in accordance with (3), if it includes compliance with AS/NZS 4020.
(2) Any product that contains copper alloy and is intended for use in contact with drinking water must have a weighted average lead content of not more than 0.25% verified in the form of either—
a test report provided by an Accredited Testing Laboratory, in accordance with NSF/ANSI/CAN 372; or
a WaterMark Licence issued in accordance with (3), if it includes compliance with NSF/ANSI/CAN 372.
(3) A product of a type listed on the WaterMark Schedule of Products is deemed to be fit for its intended purpose if it has a WaterMark Licence issued in accordance with the WaterMark Scheme Rules.
(4) A product of a type listed on the Watermark Schedule of Excluded Products requires evidence of suitability in the form of—
a current certificate issued by a certification body stating that the properties and performance of a product can meet the requirements of the PCA; or
a report issued by an Accredited Testing Laboratory that—
demonstrates that the product complies with the relevant requirements of the PCA; and
sets out the tests the product has been submitted to and the results of those tests and any other relevant information that has been relied upon to demonstrate suitability for use in a plumbing or drainage installation.
(5) Any product that is not covered by (3) or (4) must be subjected to a risk assessment in accordance with the WaterMark Scheme Rules.
(6) Evidence to support that a design or system meets the relevant PCA Performance Requirements must be in the form of any one or any combination of the following:
The design or system complies with a Deemed-to-Satisfy Provision.
The design or system is a Performance Solution from a professional engineer or a recognised expert that—
certifies that the design or system complies with the relevant requirements of the PCA; and
sets out the basis on which it is given and the extent to which relevant standards, specifications, rules, codes of practice or other publications have been relied upon.
Any other form of documentary evidence that—
demonstrates that a design or system complies with the relevant requirements of the PCA; and
sets out the basis on which it is given and the extent to which relevant standards, specifications, rules, codes of practice or other publications have been relied upon.
Notes
On-site wastewater management systems larger than covered by the standards are exempt and a Performance Solution is required.
Notes
A5G4(2) does not take effect until the completion of the transition period specified by WaterMark Notice of Direction 2021/4.
Note 1 does not prevent the use of products certified in accordance with A5G4(2) prior to the completion of the transition period specified by the WaterMark Notice of Direction 2021/4.
Applications
Products subject to the requirements of A5G4(2) are specifically nominated in the WaterMark Schedule of Products and the WaterMark Schedule of Excluded Products.
Exemptions
Products that are used exclusively for non-drinking uses such as manufacturing, industrial processing, irrigation or any other uses where water is not anticipated to be used for human consumption are excluded from the requirements of A5G4(2).