Governing requirement · NCC 2022 Volume Two

A5G3 Evidence of suitability ─ Volumes One and Two (BCA)

Part A5 Documentation of design and construction · NCC 2019: A5.2

Open A5G3 on NCC Online ↗

(1) Subject to A5G5, A5G6, A5G7 and A5G9, evidence to support that the use of a material, product, form of construction or design meets a Performance Requirement or a Deemed-to-Satisfy Provision may be in the form of any one, or any combination of the following:

A current CodeMark Australia or CodeMark Certificate of Conformity.

A current Certificate of Accreditation.

A current certificate, other than a certificate described in (a) and (b), issued by a certification body stating that the properties and performance of a material, product, form of construction or design fulfil specific requirements of the BCA.

A report issued by an Accredited Testing Laboratory that—

demonstrates that a material, product or form of construction fulfils specific requirements of the BCA; and

sets out the tests the material, product or form of construction has been subjected to and the results of those tests and any other relevant information that has been relied upon to demonstrate it fulfils specific requirements of the BCA.

A certificate or report from a professional engineer or other appropriately qualified person that—

certifies that a material, product, form of construction or design fulfils specific requirements of the BCA; and

sets out the basis on which it is given and the extent to which relevant standards, specifications, rules, codes of practice or other publications have been relied upon to demonstrate it fulfils specific requirements of the BCA.

Another form of documentary evidence, such as but not limited to a Product Technical Statement, that—

demonstrates that a material, product, form of construction or design fulfils specific requirements of the BCA; and

sets out the basis on which it is given and the extent to which relevant standards, specifications, rules, codes of practice or other publications have been relied upon to demonstrate it fulfils specific requirements of the BCA.

(2) Evidence to support that a calculation method complies with an ABCB protocol may be in the form of any one, or any combination of the following:

A certificate from a professional engineer or other appropriately qualified person that—

certifies that the calculation method complies with a relevant ABCB protocol; and

sets out the basis on which it is given and the extent to which relevant standards, specifications, rules, codes of practice and other publications have been relied upon.

Another form of documentary evidence that correctly describes how the calculation method complies with a relevant ABCB protocol.

Applications

A5G3 is only applicable to NCC Volumes One and Two (BCA).

Notes

Current documentary evidence, such as a certificate or report, containing references to NCC 2019 provisions remains valid despite amended provision references in NCC 2022, subject to technical requirements remaining the same between editions.

Changed in NCC 2025. See NCC 2025 Volume Two A5G3, or show what changed.

(1) Subject to A5G5, A5G6, A5G7 and A5G9, evidence to … 2019 provisions remains valid despite amended provision references in NCC 2022, 2022 and subsequent editions, subject to technical requirements remaining the same between editions.

Removed words are struck through; added words are highlighted. Comparison of the text only.

Clauses referred to

Defined terms used