H5P1 Movement to and within a building
Part H5 Safe movement and access · NCC 2019: P2.5.1
So that people can move safely to and within a building—
walking surfaces must have safe gradients; and
any stairway or ramp must—
have suitable handrails where necessary to assist and provide stability to people using the stairway or ramp; and
have suitable landings to avoid undue fatigue of users; and
be suitable for safe passage in relation to the nature, volume and frequency of likely usage; and
have slip-resistant walking surfaces on ramps, and on stairway treads or near the edge of the nosing.
Changed in NCC 2025. See NCC 2025 Volume Two H5P1, or show what changed.
So that people can move safely to and within a building — walking surfaces must have safe gradients; and any stairway or ramp (other than a threshold ramp) must — have suitable handrails where necessary to assist and … on stairway treads or near the edge of the nosing.
Removed words are struck through; added words are highlighted. Comparison of the text only.