H8P1 Livable housing design
Part H8 Livable housing design
A Class 1a building must be provided with—
a continuous and step-free path to a dwelling entrance door from either—
the pedestrian entry at the allotment boundary; or
an appurtenant Class 10a garage or carport; or
a car parking space provided for the exclusive use of the occupants of the dwelling; and
at least one level and step-free entrance door into the dwelling from the access path required by (a); and
internal doors and corridors on the ground or entrance level which facilitate unimpeded movement between spaces; and
a sanitary compartment that—
facilitates independent access and use; and
is located on the ground or entry level; and
a shower that facilitates independent access and use; and
the walls of the sanitary compartment referred to in (d), the shower referred to in (e) and a bath (where installed, other than a freestanding bath) constructed so as to facilitate future installation of grabrails, or the like, in a way that minimises the removal of existing wall linings.
Exemptions
H8P1(a) need not be complied with if—
step-free access cannot be provided from an appurtenant Class 10a garage or carport or a car parking space provided for the exclusive use of the occupants of the dwelling; and
due to site conditions, there is no other suitable location on which to construct the access path.