Tasmania variation · NCC 2022 Volume Two

TAS H7P3 Heating appliances

Part H7 Ancillary provisions and additional construction requirements · varies H7P3 Heating appliances

Open on NCC Online ↗

Delete clause H7P3 and insert TAS H7P3 as follows:

A heating appliance and its associated components within a building, including an open fire-place, chimney, or the like, must be installed—

to withstand the temperatures likely to be generated by the appliance; and

so that it does not raise the temperature of any building element to a level that would adversely affect the element’s physical or mechanical properties or function; and

so that hot products of combustion will not—

escape through the walls of the associated components; and

discharge in a position that will cause fire to spread to nearby combustible materials or allow smoke to penetrate through nearby windows, ventilation inlets, or the like in the building containing the heating appliance; and

in the case of solid-fuel burning appliances, be discharged above appropriate emission limits.

Same wording in NCC 2025 Volume Two. See NCC 2025 Volume Two TAS H7P3.

The national clause