Housing Provisions clause · ABCB Housing Provisions 2025

10.3.1 Height of rooms and other spaces

Part 10.3 Room heights · NCC 2019: 3.8.2.2

Open 10.3.1 on NCC Online ↗

(1) Heights of rooms and other spaces (see Figure 10.3.1) must be not less than—

in a habitable room excluding a kitchen — 2.4 m; and

in a kitchen — 2.1 m; and

in a corridor, passageway or the like — 2.1 m; and

in a bathroom, shower room, laundry, sanitary compartment, airlock, pantry, storeroom, garage, car parking area or the like — 2.1 m; and

in a room or space with a sloping ceiling or projections below the ceiling line within—

a habitable room —

in an attic — a height of not less than 2.2 m for at least two-thirds of the floor area of the room or space; and

in other rooms — a height of not less than 2.4 m over two-thirds of the floor area of the room or space; and

a non-habitable room — a height of not less than 2.1 m for at least two-thirds of the floor area of the room or space; and

in a stairway, ramp (other than a threshold ramp), landing, or the like — 2.0 m measured vertically above the nosing line of stairway treads or the floor surface of a ramp, landing or the like.

(2) For the purposes of (1)(e), when calculating the floor area of a room or space, any part that has a ceiling height of less than 1.5 m is not included.

Figure 10.3.1 Measurement of heights of rooms and other spaces

Figure Notes

The letters in the diagram represent the following minimum dimensions:

A = 2.4 m In a habitable room (excluding a kitchen).

B = 2.4 m In a habitable room with a sloping ceiling for at least two-thirds of the floor area of the room or space.

C = 2.1 m In a non-habitable room with a sloping ceiling for at least two-thirds of the floor area of the room or space.

D = 2.2 m In an attic with a sloping ceiling for at least two-thirds of the floor area of the room or space.

E = 1.5 m For the purpose of calculating the floor area of a room or space, any ceiling height of less than 1.5 m is excluded.

F = 2.0 m In a stairway (measured vertically above the nosing line).

The combined dimensions of G must not exceed one-third of the floor area (see E above) of the room or space.

Changed since NCC 2022. See ABCB Housing Provisions 2022 10.3.1, or show what changed.

(1) Heights of rooms and other spaces (see Figure 10.3.1) … area of the room or space; and in a stairway, ramp, ramp (other than a threshold ramp), landing, or the like — 2.0 m measured vertically above … floor area (see E above) of the room or space.

Removed words are struck through; added words are highlighted. Comparison of the text only.

Defined terms used