(1) Handrails to a stairway or ramp must—

be located along at least one side of the stairway flight or ramp; and

be located along the full length of the stairway flight or ramp, except in the case where a handrail is associated with a barrier the handrail may terminate where the barrier terminates; and

have the top surface of the handrail not less than 865 mm vertically above the nosings of the stair treads or the floor surface of the ramp (see Figure 11.3.4b); and

be continuous and have no obstruction on or above them that will tend to break a handhold, except for newel posts, ball type stanchions, or the like.

(2) The requirements of (1) do not apply to—

a stairway or ramp providing a change in elevation of less than 1 m; or

a landing; or

a winder where a newel post is installed to provide a handhold; or

A handrail complying with AS 1657 serving a stairway provided in accordance with 11.2.7(a).