Housing Provisions clause · ABCB Housing Provisions 2025

11.3.7 Protection of openable windows – bedrooms

Part 11.3 Barriers and handrails · NCC 2019: 3.9.2.6

Open 11.3.7 on NCC Online ↗

(1) A window opening in a bedroom must be provided with protection, where the floor below the window is 2 m or more above the surface beneath.

(2) Where the lowest level of the window opening covered by (1) is less than 1.7 m above the floor, the window opening must comply with the following:

The openable portion of the window must be protected with—

a device capable of restricting the window opening; or

a screen with secure fittings.

A device or screen required by (a) must—

not permit a 125 mm sphere to pass through the window opening or screen; and

resist an outward horizontal action of 250 N against the—

window restrained by a device; or

screen protecting the opening; and

have a child resistant release mechanism if the screen or device is able to be removed, unlocked or overridden.

(3) Where a device or screen provided in accordance with (2)(a) is able to be removed, unlocked or overridden, a barrier with a height not less than 865 mm above the floor is required to an openable window in addition to window protection.

(4) A barrier covered by (3) must not—

permit a 125 mm sphere to pass through it; and

have any horizontal or near horizontal elements between 150 mm and 760 mm above the floor that facilitate climbing (see Figure 11.3.7).

Figure 11.3.7 Protection of openable windows — bedrooms

Same wording in ABCB Housing Provisions 2022. See ABCB Housing Provisions 2022 11.3.7.

Defined terms used