12.2.4 Clear spaces around buildings
Part 12.2 Construction in alpine areas · NCC 2019: 3.10.4.4]
A building must be constructed so that—
for any external walls more than 3.6 m above the natural ground level, the distance of that part of the building from the allotment boundary (other than a road alignment) must be not less than 2.5 m plus an additional 100 mm for each 300 mm or part by which that part of the external wall exceeds a height of 3.6 m (see Figure 12.2.4a); and
if an external doorway discharges into a court between wings of a building and that area may be used for vehicle access to the building, the clear distance between wings must be not less than 4 m (see Figure 12.2.4b); and
where an external doorway discharges opposite a feature that could trap snow or an embankment that is more than 900 mm above the threshold of that doorway, a minimum clear distance of not less than 4 m must be provided between the door and the feature (see Figure 12.2.4c and Figure 12.2.4d).
Figure 12.2.4a Clear spaces around buildings — Set-back from allotment boundary where wall exceeds 3.6 m
Figure 12.2.4b Clear spaces around buildings — External doorway discharging into a court between wings of a building
Figure 12.2.4c Clear spaces around buildings — Embankments adjoining buildings
Figure 12.2.4d Clear spaces around buildings — Use of a threshold where clear space is not available