Housing Provisions clause · ABCB Housing Provisions 2025

12.3.3 Flashings to the junction of the waling plate and external wall

Part 12.3 Attachment of framed decks and balconies to external walls of buildings using a waling plate · NCC 2019: 3.10.6.3

Open 12.3.3 on NCC Online ↗

Where the wall cladding is removed to attach a waling plate, openings in external wall cladding exposed to the weather must be flashed with materials complying with AS/NZS 2904 and in accordance with the following:

Flashings must be provided to bottom, tops and the sides of the junction of the waling plate and the external wall, and must be installed so that the flashing —

extends not less than 150 mm beyond each side of the waling plate where practicable; and

is attached to the waling plate and wall framing; and

at the top and bottom of the waling plate, drains to the outside face of the wall or cladding.

Joins in the flashing must—

overlap by not less than 75 mm in the direction of flow; and

be securely fastened at intervals of not more than 40 mm; and

have sealant installed between laps.

The method of flashing must be suitable for the framing and cladding used.

Flashings must be securely fixed at least 25 mm under the cladding at ends and edges of the framing of the opening.

Same wording in ABCB Housing Provisions 2022. See ABCB Housing Provisions 2022 12.3.3.

Defined terms used