4.2.17 Footings for single leaf masonry, mixed construction and earth wall construction
Part 4.2 Footings, slabs and associated elements · NCC 2019: 3.2.5.2
Footings supporting the following external wall types must comply with the equivalent wall construction set out in Tables 4.2.17a, 4.2.17b and 4.2.17c:
Single leaf masonry.
Mixed construction.
Earth wall structures.
Table 4.2.17a Equivalent wall construction: single leaf masonry
Actual construction: external walls
Actual construction: internal walls
Equivalent wall construction
Reinforced single leaf masonry
Articulated masonry on Class A and Class S sites, or framed
Articulated masonry veneer
Reinforced single leaf masonry
Articulated masonry or reinforced single leaf masonry
Masonry veneer
Articulated single leaf masonry
Articulated masonry
Articulated full masonry
Table 4.2.17b Equivalent wall construction: mixed construction
Actual construction: external walls
Actual construction: internal walls
Equivalent wall construction
Full masonry
Framed
Articulated full masonry
Articulated full masonry
Framed
Masonry veneer
Table 4.2.17c Equivalent wall construction: earth wall construction
Actual construction: external walls
Actual construction: internal walls
Equivalent wall construction
Infill panels of earth wall construction
Framed earth wall construction
Articulated masonry veneer
Load bearing earth wall construction
Load bearing earth wall construction
Articulated full masonry
Tables
- Table 4.2.17a Equivalent wall construction: single leaf masonry
- Table 4.2.17b Equivalent wall construction: mixed construction
- Table 4.2.17c Equivalent wall construction: earth wall construction