Housing Provisions clause · ABCB Housing Provisions 2025

4.2.19 Shrinkage control

Part 4.2 Footings, slabs and associated elements · NCC 2019: 3.2.5.3

Open 4.2.19 on NCC Online ↗

Where brittle floor coverings, such as ceramic tiles, are to be used over an area greater than 16 m2, one of the following additional measures must be taken to control the effect of shrinkage cracking—

the amount of shrinkage reinforcement (steel reinforcement mesh in the slab panel) must be—

increased to SL92 or equivalent throughout the affected slab area; or

reinforced top and bottom with sheets of slab mesh throughout the affected slab area; or

the bedding system for brittle coverings must be selected on the basis of the expected slab movement and the characteristics of the floor covering (including the use of expansion joints etc.); or

the placement of floor covering must be delayed for not less than 3 months after the concrete has been poured.

Same wording in ABCB Housing Provisions 2022. See ABCB Housing Provisions 2022 4.2.19.

Defined terms used