8.4.2 Doors, side panels and other framed glazed panels
Part 8.4 Glazing human impact · NCC 2019: 3.6.4.1
Glass in doors must be Grade A safety glazing material in accordance with Table 8.4.2 and Figure 8.4.2, except that—
unframed doors, other than those incorporated in shower screens or bath enclosures, must be glazed with toughened safety glass with a minimum nominal thickness of 10 mm or laminated toughened safety glass with a minimum total thickness of 10 mm; and
individual pieces of monolithic annealed glass incorporated in leadlights may be used, to a maximum area of 0.05 m2 with a minimum nominal thickness of 3 mm; and
for annealed and annealed decorated glass panels in doors—
for 3 mm and 4 mm annealed glass, the maximum area must not be more than 0.1 m2 with a maximum panel width of 125 mm; and
for 5 mm and 6 mm annealed glass, the maximum area must not be more than 0.26 m2 with a maximum panel width of 300 mm; and
for annealed glass in fully framed panels with a thickness of 10 mm or more, with or without bevelled edges, the maximum area must not be more than 0.5 m2; and
doors in bathrooms, ensuites and spa rooms must be glazed in accordance with 8.4.6.
Table 8.4.2 Maximum areas of glazing material for framed glass doors, framed glass side panels and other framed glazed panels
Type of glass
Minimum nominal thickness (mm)
Maximum area of pane (m2)
Patterned or clear monolithic annealed glass
5
0.3
Patterned or clear monolithic annealed glass
6
0.9
Grade A toughened and toughened laminated safety glass
3
1
Grade A toughened and toughened laminated safety glass
4
2
Grade A toughened and toughened laminated safety glass
5
3
Grade A toughened and toughened laminated safety glass
6
4
Grade A laminated safety glass
5.38
2.2
Grade A laminated safety glass
6.38
3
Grade A laminated safety glass
8.38
5
Figure 8.4.2 Identification of glazing requirements for doors and side panels
Figure Notes
For door and side panel glazing areas – see Table 8.4.2.