Table 13.2.3j Flat, skillion or cathedral roof – minimum R-Value for ceiling insulation: climate zone 1 – single storey dwelling
| Reflective insulation under-roof | SA ≤ 0.23 | 0.23 < SA ≤ 0.32 | 0.32 < SA ≤ 0.42 | 0.42 < SA ≤ 0.53 | 0.53 < SA ≤ 0.64 |
|---|---|---|---|---|---|
| Yes | 1.0 | 2.0 | 2.0 | 4.0 | 4.0 |
| No | 1.0 | 3.5 | X | X | X |
Table Notes
SA = solar absorptance.
The R-Value can be achieved by installing insulation under the roof or on the top of the ceiling or a combination of both.
The R-Value of reflective insulation is not to be included in the R-Value of any under-roof or ceiling insulation.
R-Values listed are for the labelled, declared R-Value of insulation.
X = not permitted.
Table for 13.2.3 Roofs and ceilings
Same wording in ABCB Housing Provisions 2022. See ABCB Housing Provisions 2022 Table 13.2.3j.