Table 4.2.13a Stumps supporting single storey timber floor and metal roof
Part 4.2 Footings, slabs and associated elements
| Floor load area (m2) | Dimension (mm) | Roof load area (m2) | ||
|---|---|---|---|---|
| 0 | 6 | 12 | ||
| 3 | Square pad footing size | 250 x 250 | 300 x 300 | 350 x 350 |
| 8 | Square pad footing size | 400 x 400 | 400 x 400 | 450 x 450 |
| 12 | Square pad footing size | 450 x 450 | 500 x 500 | 500 x 500 |
| 3 | Circular pad footing diameter | 300 | 400 | 400 |
| 8 | Circular pad footing diameter | 450 | 450 | 600 |
| 12 | Circular pad footing diameter | 600 | 600 | 600 |
| 3 | Pad footing depth | 250 | 250 | 250 |
| 8 | Pad footing depth | 250 | 250 | 250 |
| 12 | Pad footing depth | 250 | 250 | 250 |
Table Notes
Load accounted for includes 0.53 kPa permanent floor, 0.92 kN/m permanent wall, 0.4 kPa permanent roof, permanent member self-weight, 1.5 kPa or 1.1 kN imposed floor and 0.25 kPa imposed roof.
Load combinations for ULS included are 1.35G and 1.2G + 1.5Q for stumps and G + 0.5Q for pad footings.
Minimum bearing pressure is 100 kPa for pad footings.
For pad footings founded on rock, the width or diameter may be reduced by half but not less than 250 mm x 250 mm or 300 mm diameter.
Stumps are assumed to be braced and simply-supported at both ends with an effective length factor of 1.
A maximum load eccentricity of length/100 has been accounted for in the stumps.
A roof load area of “0” must be used for stumps not supporting roof loads.
The length of wall load allowed for is equal to the square root of the floor area.
Table for 4.2.13 Stump footing details