Western Australia variation · ABCB Housing Provisions 2025

WA 9.6.1 Measurement of distances

WA Part 9.6 Fire separation of roofed outdoor areas

Open on NCC Online ↗

Delete clause 9.6.1 and insert WA 9.6.1 as follows:

(1) For roofed outdoor areas complying with WA 9.6.2(1) the distance is measured between the outermost structural projection of the roofed outdoor area and—

the allotment boundary; or

the external wall of another building on the same allotment; or

the outermost structural projection of another roofed outdoor area on the same allotment (see WA Figure 9.6.1a).

(2) For roofed outdoor areas complying with WA 9.6.2(3) the distance is measured to the outermost projection of the roofed outdoor area and—

the allotment boundary; or

the external wall of another building on the same allotment including the outermost projection of any encroachment; or

the outermost projection of another roofed outdoor area (see WA Figure 9.6.1b) on the same allotment; or

the external wall of the building including the outermost projection of any encroachment.

(3) The distance from any point on a roofed outdoor area to an allotment boundary, another building or another roofed outdoor area is the distance to that point measured in accordance with (1) and (2) along a line at right angles, without being obstructed by a wall complying with 9.2.3.

(4) Where the distance measured is between attached or detached buildings of different heights, the distance must be taken from the external wall or, in relation to a roofed outdoor area, the outermost structural projection in accordance with 9.6.1(1) or, the outermost projection in accordance with 9.6.1(2) with the highest elevation measured at right angles to a point that intersects the nearest part of a vertical projection above the adjacent building and—

for roofed outdoor areas complying with WA 9.6.2(1) the measurement excludes any eave overhang (see WA Figure 9.6.1c); and

for roofed outdoor areas complying with WA 9.6.2(3) the measurement includes any eave overhang measured to the outermost projection (see WA Figure 9.6.1d).

Insert WA figure (9.6.1a) 9.6.1 as follows:

WA Figure 9.6.1a: Measurement of distance to outermost structural projection

Figure Notes

The outermost structural projection will typically be the outside face of the fascia, or the roof structure where there is no fascia.

Insert WA figure (9.6.1b) 9.6.1 as follows:

WA Figure 9.6.1b: Measurement of distance to outermost projection

Figure Notes

The outermost projection will typically be the outside face or leading edge of the rainwater fittings, or the roof cover where there are no rainwater fittings.

Insert WA figure (9.6.1c) 9.6.1 as follows:

WA Figure 9.6.1c: Measurement of distance — buildings of different heights on the same allotment — roofed outdoor area complying with WA 9.6.2(1)

Insert WA figure (9.6.1d) 9.6.1 as follows:

WA Figure 9.6.1d: Measurement of distance — buildings of different heights on the same allotment — roofed outdoor area complying with WA 9.6.2(3)

New in NCC 2025. No WA 9.6.1 in ABCB Housing Provisions 2022; it may have moved or been renumbered.