TAS C4D18 Mixing tanks

TAS Part C4 On-site liquid trade waste systems

Open on NCC Online ↗

Delete clause C4D18 and insert TAS C4D18 as follows:

(1) The capacity of a mixing tank must be authorised by the Permit Authority.

(2) A mixing tank and baffles must be constructed of a minimum—

6 mm PVC-U sheet; or

0.63 mm acid resistant stainless steel all welded construction; or

other authorised acid and alkali resistant material.

(3) A mixing tank must contain three equally spaced baffles.

(4) A mixing tank pipe diameter must be—

DN 100 when the pipe inlet size is DN 100; or

a minimum of one size larger than the inlet pipe.

(5) The outlet of a mixing tank must include a 32 mm x 32 mm x 25 mm deep PVC-U test block bracket fitted as near as practicable to the outlet.

(6) A mixing tank must include a 150 mm x 25 mm x 25 mm cement mortar test block fitted to the satisfaction of the Permit Authority.

(7) A mixing tank must be located in a position that—

enables ready access for maintenance and inspection; and

provides ready access for fitting of the cement mortar test block; and

enables ready access to the sampling valve.

(8) When a mixing tank is to be located below ground, it must—

be surrounded with concrete walls and base with a minimum thickness of 100 mm; and

omit the 25 mm sampling valve; and

have a minimum DN 100 outlet pipe located no deeper than 600 mm below surface level; and

have the outlet pipe connected to a disconnector gully fitted with a loose fitting grate or screw cap.

Exemptions

The minimum capacity requirement of a typical mixing tank in accordance with C4D18(1) is 100 litres.

Changed since NCC 2022. See NCC 2022 Volume Three TAS C4D18, or show what changed.

Delete clause C4D18 and insert TAS C4D18 as follows: (1) The capacity of a mixing tank must be authorised … typical mixing tank in accordance with C4D18(1) is 100 litres.

Removed words are struck through; added words are highlighted. Comparison of the text only.