TAS C4D2 General requirements
TAS Part C4 On-site liquid trade waste systems
Delete clause C4D2 and insert TAS C4D2 as follows:
(1) Where pre-treatment facilities are installed, they must comply with the requirements of—
the Network Utility Operator (where applicable); and
occupational health and safety; and
dangerous goods management; and
environmental protection.
(2) A liquid trade waste system that discharges to a Network Utility Operator's sewerage system after pre-treatment must—
be capable of discharging liquid trade waste at a quality set under a Consent to Discharge issued for that equipment or system by the Network Utility Operator; and
the sanitary drainage system must comply with:
AS/NZS 3500.2; and
the Network Utility Operator's guidelines, insofar as the provisions relate to the system.
Changed since NCC 2022. See NCC 2022 Volume Three TAS C4D2, or show what changed.