TAS C4D7 Connections
TAS Part C4 On-site liquid trade waste systems
Delete clause C4D7 and insert TAS C4D7 as follows:
(1) The plumbing and drainage installation upstream of a low-risk trade waste appliance must comply with AS/NZS 3500.2
(2) The sanitary plumbing and drainage system must be compatible to the nature of the waste.
(3) A trap must be fitted to every fixture or appliance outlet and must be—
DN 50 minimum for a portable appliance with hydraulic loading up to 5 fixture units; or
DN 80 minimum for a portable appliance with hydraulic loading greater than 5 fixture units; or
DN 100 minimum for all other appliances.
Exemptions
Installations outside C4D7(1) may be permitted by the Permit Authority.
Changed since NCC 2022. See NCC 2022 Volume Three TAS C4D7, or show what changed.
Delete clause C4D7 and insert TAS C4D7 as follows: (1) The plumbing and drainage installation upstream of a low-risk … Installations outside C4D7(1) may be permitted by the Permit Authority.
Removed words are struck through; added words are highlighted. Comparison of the text only.