Part A5 Documentation of design and construction · NCC 2019: A5.6

Open A5G7 on NCC Online ↗

A ceiling is deemed to have a resistance to the incipient spread of fire to the space above itself if—

it is identical with a prototype that has been submitted to the Standard Fire Test and the resistance to the incipient spread of fire achieved by the prototype is confirmed in a report from an Accredited Testing Laboratory that—

describes the method and conditions of the test and form of construction of the tested prototype in full; and

certifies that the application of restraint to the prototype complies with the Standard Fire Test; or

it differs in only a minor degree from a prototype tested under (a) and the resistance to the incipient spread of fire attributed to the ceiling is confirmed in a report from an Accredited Testing Laboratory that—

certifies that the ceiling is capable of achieving the resistance to the incipient spread of fire despite the minor departures from the tested prototype; and

describes the materials, construction and conditions of restraint that are necessary to achieve the resistance to the incipient spread of fire.

Same wording in NCC 2022 Volume Two. See NCC 2022 Volume Two A5G7.