Definition · NCC 2025 Volume Two

Point of connection

Any of the following:

For a cold water service, means the point where the cold water service connects to—

the Network Utility Operator's water supply system; or

the point of isolation to an alternative water source where there is no Network Utility Operator's water supply available or is not utilised.

For a heated water service, means the point where the water heater connects to the cold water service downstream of the isolation valve.

For sanitary drainage, means the point where the on-site sanitary drainage system connects to—

the Network Utility Operator's sewerage system; or

an on-site wastewater management system.

For sanitary plumbing, means the point where the sanitary plumbing system connects to the sanitary drainage system.

For a rainwater service, means the point where the rainwater service —

connects to the point of isolation for the rainwater storage; or

draws water from the rainwater storage.

For stormwater disposal, means the point where the on-site stormwater drainage system connects to—

the Network Utility Operator's stormwater system; or

an approved on-site disposal system.

For a fire-fighting water service, means the point where the service connects to—

a cold water service, downstream of a backflow prevention device; or

the Network Utility Operator's water supply system; or

the point of isolation to an alternative water source.

For rainwater storage, means the point of rainwater entry to the rainwater storage.

Notes

A domestic fire sprinkler service conforming to FPAA101D is considered part of the cold water service.

Used in