H5P2 Fall prevention barriers
Part H5 Safe movement and access · NCC 2019: P2.5.2
(1) A barrier must be provided where people could fall—
1 m or more—
from a floor or roof or through an opening (other than through an openable window) in the external wall; or
due to a sudden change of level within or associated with a building; or
2 m or more from a floor through an openable window in a bedroom; or
4 m or more from a floor through an openable window not covered by (b).
(2) A barrier required by (1) must be—
continuous and extend for the full extent of the hazard; and
of a height to protect people from accidentally falling from the floor or roof or through the opening or openable window; and
constructed to prevent people from falling through the barrier; and
capable of restricting the passage of children; and
of strength and rigidity to withstand—
the foreseeable impact of people; and
where appropriate, the static pressure of people pressing against it.