Performance Requirement · NCC 2025 Volume Two

H5P2 Fall prevention barriers

Part H5 Safe movement and access · NCC 2019: P2.5.2

Open H5P2 on NCC Online ↗

(1) A barrier must be provided where people could fall—

1 m or more—

from a floor or roof or through an opening (other than through an openable window) in the external wall; or

due to a sudden change of level within or associated with a building; or

2 m or more from a floor through an openable window in a bedroom; or

4 m or more from a floor through an openable window not covered by (b).

(2) A barrier required by (1) must be—

continuous and extend for the full extent of the hazard; and

of a height to protect people from accidentally falling from the floor or roof or through the opening or openable window; and

constructed to prevent people from falling through the barrier; and

capable of restricting the passage of children; and

of strength and rigidity to withstand—

the foreseeable impact of people; and

where appropriate, the static pressure of people pressing against it.

Same wording in NCC 2022 Volume Two. See NCC 2022 Volume Two H5P2.