NT H6P1 Building
NT Part H6 Energy efficiency · varies H6P1 Thermal performance
Insert NT clause H6P1 in clause H6P1 as follows:
A building must have, to the degree necessary, a level of thermal performance to facilitate the efficient use of energy for artificial heating and cooling appropriate to—
the function and use of the building; and
the internal environment; and
the geographic location of the building; and
the effects of nearby permanent features such as topography, structures and buildings; and
solar radiation being
utilised for heating; and
controlled to minimise energy for cooling; and
the sealing of the building envelope against air leakage; and
the utilisation of air movement to assist cooling.
Changed since NCC 2022. See NCC 2022 Volume Two NT H6P1, or show what changed.
Insert NT clause H6P1 in clause H6P1 as follows: A building must have, to the degree necessary, a level … leakage; and the utilisation of air movement to assist cooling.
Removed words are struck through; added words are highlighted. Comparison of the text only.