Performance Requirement · NCC 2025 Volume One
E4P1 Visibility in an emergency
Part E4 Visibility in an emergency, exit signs and warning systems · NCC 2019: EP4.1
To facilitate safe evacuation in an emergency, a building must be provided with a system that—
ensures a level of visibility sufficient to enable exits, paths of travel to exits and any obstacles along a path of travel to an exit to be identified; and
activates instantaneously upon the failure of an artificial lighting system, to the degree necessary, appropriate to—
the function or use of the building; and
the floor area of the building; and
the distance of travel to an exit.
Limitations
E4P1 does not apply to the internal parts of a sole-occupancy unit in a Class 2, 3 or 9c building or Class 4 part of a building.
Same wording in NCC 2022 Volume One. See NCC 2022 Volume One E4P1.