Deemed-to-Satisfy Provision · NCC 2025 Volume One

F5D2 Height of rooms and other spaces

Part F5 Room heights · NCC 2019: F3.1

Open F5D2 on NCC Online ↗

(1) The height of rooms and other spaces in a Class 2 or 3 building or Class 4 part of a building must be not less than—

for a kitchen, laundry, or the like — 2.1 m; and

for a corridor, passageway or the like — 2.1 m; and

for a habitable room excluding a kitchen — 2.4 m; and

in a habitable room, or space within a habitable room, with a sloping ceiling or projections below the ceiling line—

in an attic — a height of not less than 2.2 m for not less than two-thirds of the floor area of the room or space; and

in other rooms — a height of not less than 2.4 m for not less than two-thirds of the floor area of the room or space; and

in a non-habitable room, or space within a non-habitable room, with a sloping ceiling or projections below the ceiling line — a height of not less than 2.1 m for not less than two-thirds of the floor area of the room or space.

(2) For the purposes of (1), when calculating the floor area of a room or space, any part that has a ceiling height of less than 1.5 m is not included.

(3) The height of rooms and other spaces in a Class 5, 6, 7 or 8 building must be not less than—

except as allowed in (b) and (8) — 2.4 m; and

for a corridor, passageway, or the like — 2.1 m.

(4) The height of rooms and other spaces in a Class 9a health-care building must be not less than—

for a patient care area — 2.4 m; and

for an operating theatre or delivery room — 3 m; and

for a treatment room, clinic, waiting room, passageway, corridor, or the like — 2.4 m.

(5) The height of rooms and other spaces in a Class 9b building must be not be less than—

for a school classroom or other assembly building or part that accommodates not more than 100 persons — 2.4 m; and

for a theatre, public hall or other assembly building or part that accommodates more than 100 persons — 2.7 m; and

for a corridor—

that serves an assembly building or part that accommodates not more than 100 persons — 2.4 m; or

that serves an assembly building or part that accommodates more than 100 persons — 2.7 m.

(6) For the purposes of (5) the number of persons accommodated must be calculated according to D2D18.

(7) The height of rooms and other spaces in a Class 9c building must be not be less than—

for a kitchen, laundry, or the like — 2.1 m; and

for a corridor, passageway or the like — 2.4 m; and

for a habitable room excluding a kitchen — 2.4 m.

(8) The height of rooms and other spaces in any building must be not be less than—

for a bathroom, shower room, sanitary compartment, other than an accessible adult change facility, airlock, tea preparation room, pantry, store room, garage, car parking area, or the like — 2.1 m; and

for a commercial kitchen — 2.4 m; and

above a stairway, ramp (other than a threshold ramp), landing or the like — 2 m measured vertically above the nosing line of stairway treads or the floor surface of the ramp, landing or the like; and

for a required accessible adult change facility — 2.4 m.

Changed since NCC 2022. See NCC 2022 Volume One F5D2, or show what changed.

(1) The height of rooms and other spaces in a … a commercial kitchen — 2.4 m; and above a stairway, ramp, ramp (other than a threshold ramp), landing or the like — 2 m measured vertically above … for a required accessible adult change facility — 2.4 m.

Removed words are struck through; added words are highlighted. Comparison of the text only.

Can't meet F5D2? A Performance Solution must meet the Performance Requirements it satisfies: F5P1. Start a Performance Solution →

Clauses referred to