Performance Requirement · NCC 2025 Volume One

G2P1 Combustion heating appliances

Part G2 Boilers, pressure vessels, heating appliances, fireplaces, chimneys and flues · NCC 2019: GP2.1

Open G2P1 on NCC Online ↗

Where provided in a building, a combustion appliance and its associated components, including an open fire-place, chimney, flue, chute, hopper or the like, must be installed—

to withstand the temperatures likely to be generated by the appliance; and

so that it does not raise the temperature of any building element to a level that would adversely affect the element’s physical or mechanical properties or function; and

so that hot products of combustion will not—

escape through the walls of the associated components; and

discharge in a position that will cause fire to spread to nearby combustible materials or allow smoke to penetrate through nearby windows, ventilation inlets, or the like.

Same wording in NCC 2022 Volume One. See NCC 2022 Volume One G2P1.