G2P1 Combustion heating appliances
Part G2 Boilers, pressure vessels, heating appliances, fireplaces, chimneys and flues · NCC 2019: GP2.1
Where provided in a building, a combustion appliance and its associated components, including an open fire-place, chimney, flue, chute, hopper or the like, must be installed—
to withstand the temperatures likely to be generated by the appliance; and
so that it does not raise the temperature of any building element to a level that would adversely affect the element’s physical or mechanical properties or function; and
so that hot products of combustion will not—
escape through the walls of the associated components; and
discharge in a position that will cause fire to spread to nearby combustible materials or allow smoke to penetrate through nearby windows, ventilation inlets, or the like.