Specification clause · NCC 2025 Volume One

S26C3 Shower area (enclosed and unenclosed)

Specification 26 Waterproofing and water-resistance requirements for building elements in wet areas · NCC 2019: Table F1.7

Open S26C3 on NCC Online ↗

(1) For a shower area with a hob, step-down or level threshold, the following applies:

The floor of the shower area must be waterproof, including any hob or step-down; and

The walls of the shower area must be waterproof not less than 1800 mm above the floor substrate.

Wall junctions and joints within the shower area must be waterproof.

Wall/floor junctions within the shower area must be waterproof.

Penetrations within the shower area must be waterproof.

(2) A shower with a preformed shower base must also comply with the requirements of (1), except for (a) which is not applicable.

Same wording in NCC 2022 Volume One. See NCC 2022 Volume One S26C3.

Defined terms used