Specification clause · NCC 2025 Volume One

S28C10 Acceptable forms of construction for floors — timber

Specification 28 Sound insulation for building elements · NCC 2019: Spec F5.2: Table 3

Open S28C10 on NCC Online ↗

(1) Acceptable forms of construction for timber floors are set out in (2) and (3).

(2) 19 mm thick particleboard floor sheeting with—

190 mm x 45 mm timber joists at 450 mm centres; and

R2.5 glass or mineral wool insulation positioned between timber joists; and

28 mm metal furring channels and isolation mounts fixed to underside of joists, isolation mounts to be of natural rubber with a dynamic factor of not more than 1.1 and static deflection of not less than 3 mm at actual operating load; and

two layers of 16 mm fire-protective grade plasterboard fixed to furring channels,

has an Rw + Ctr of not less than 50, an Ln,w of not more than 62 and an Rw of not less than 50, if constructed as shown in Figure S28C10a.

(3) Timber flooring with minimum 8.5 kg/m² mass, over 19 mm thick particleboard floor sheeting with—

190 mm x 45 mm timber joists at not less than 450 mm centres; and

R2.5 glass or mineral wool insulation positioned between timber joists; and

28 mm metal furring channels fixed to underside of joists at 600 mm centres by clip or mount; and

one layer of 13 mm acoustic grade plasterboard fixed to furring channels,

has an Rw + C of not less than 45 and an Rw of not less than 45, if constructed as shown in Figure S28C10b.

Figure S28C10a 19 mm thick particleboard floor sheeting

Figure S28C10b Timber flooring with minimum 8.5kg/m² mass, over 19 mm thick particleboard floor sheeting

Same wording in NCC 2022 Volume One. See NCC 2022 Volume One S28C10.

Defined terms used