S6C9 Testing of specimens
Specification 6 Structural tests for lightweight construction · NCC 2019: Spec C1.8: 4.3
If a laboratory specimen is tested, the specimen must span only in the direction corresponding to the height of the wall and testing must be done in accordance with either (a) or (b) below:
The test specimen—
height (or length, if the specimen is tested horizontally) must be identical with the height between supports in the actual construction; and
must be supported at the top and bottom (or at each end if tested horizontally) by components identical with, and in a manner identical with, the actual construction.
If the distance between supports of the actual construction is more than 3 m, then a smaller specimen may be tested but—
the distance between supports must be not less than 3 m; and
forces, reactions and support conditions must be modelled so as to reproduce the behaviour of the actual construction if it were tested in-situ.