Specification 15 Braille and tactile signs
6 clauses · Open on NCC Online ↗
- S15C1 ScopeThis Specification sets out the requirements for the design and installation of braille and tactile signage as required by D3D26, D4D7 and…
- S15C2 Location of braille and tactile signsSigns including symbols, numbering and lettering must be designed and installed as follows: Braille and tactile components of a sign must be located…
- S15C3 Braille and tactile sign specificationTactile characters must be raised or embossed to a height of not less than 1 mm and not more than 1.5 mm. (2) Title case must be used for all…
- S15C4 Luminance contrastThe following applies to luminance contrast: The background, negative space, fill of a sign or border with a minimum width of 5 mm must have a…
- S15C5 LightingBraille and tactile signs must be illuminated to ensure luminance contrast requirements are met at all times during which the sign is required to be…
- S15C6 BrailleThe following applies to braille: Braille must be grade 1 braille (uncontracted) in accordance with the criteria set out by the Australian Braille…