Table · NCC 2025 Volume One
Table J3D11n Orientation sector conductance factor (OC)
Part J3 Elemental provisions for a Class 4 part of a building
| Climate zone | North | North east | East | South east | South | South west | West | North west |
|---|---|---|---|---|---|---|---|---|
| 2 | 1.70 | 1.34 | 0.98 | 0.84 | 0.70 | 0.90 | 1.10 | 1.40 |
| 3 | 1.30 | 1.10 | 0.90 | 0.95 | 1.00 | 0.95 | 0.90 | 1.10 |
| 4 | 1.30 | 1.25 | 1.20 | 1.03 | 0.85 | 0.92 | 0.99 | 1.15 |
| 5 | 1.20 | 1.15 | 1.10 | 1.05 | 1.00 | 1.05 | 1.10 | 1.15 |
| 6 | 1.23 | 1.13 | 1.00 | 1.00 | 1.02 | 1.00 | 1.00 | 1.16 |
| 7 and 8 | 1.40 | 1.25 | 1.10 | 1.00 | 0.90 | 0.95 | 1.00 | 1.20 |
Table for J3D11 External winter glazing of a Class 4 part of a building
Same wording in NCC 2022 Volume One. See NCC 2022 Volume One Table J3D11n.